Abstract
The degradation behavior of polymer coatings is essential for their protective performance under various corrosive environments. Herein, electrochemical impedance spectroscopy (EIS) is employed to study the corrosion behavior and interfacial delamination of a polymer-coated metal system exposed to 0.1, 0.5, and 1 mol/L H2SO4 solutions at 50 °C. The electrochemical impedance spectra are analyzed using different equivalent circuits to derive the time dependence of the parameters of the coating, delaminated area, and interfacial processes. The phase angle at 10 Hz (θ10 Hz) is not appropriate in the case of higher delamination area ratio α, while θ10 kHz provides a rapid approach to evaluate the degradation of polymer-coated metal systems. The frequency of the phase angle at −45° (f–45°) leads to a wrong evaluation for higher α and can be no longer viewed as the breakpoint frequency. The frequency fp obtained by the changing rate of phase angle (CRPA) method is proposed to monitor the coating degradation and determine the breakpoint frequency with the consideration of dispersive number n. The frequency fEIS derived from fitting EIS spectra shows a good agreement with fp, which can contribute to clarify the evolution in the process of degradation.
1. Introduction
Polymer coatings have been widely used for protecting the metal substrate against corrosion.1−6 The polymer-coated metal systems usually exhibit excellent protective performance behavior in NaCl solutions, whereas the more corrosive environment such as the acid media would cause the deterioration of coatings and result in blisters.7
Electrochemical impedance spectroscopy (EIS) has been one of the main methods to evaluate the performance of polymer-coated metal systems. Electrical equivalent circuit models are established to simulate the EIS spectra.8−12 Several attempts have been made to derive the electrochemical parameters such as coating capacitance Cc, pore resistance Rp, double-layer capacitance Cdl, and charge transfer resistance Rct, which are associated with the degradation of the system.13−17 Some rapid evaluation methods derived from the EIS spectra can contribute to understand the deterioration of the polymer-coated metal system for industrial application such as routine batch testing. The degradation of polymer-coated metal systems is associated with several parameters such as the phase angles at different frequencies, the changing rate of impedance, and breakpoint frequency fb. Mahdavian and Attar compared the phase angles at 10 kHz in terms of the zinc chromate and zinc phosphate coatings and concluded that the parameter has a good agreement with other extracted parameters.18 Zuo et al. used the phase angle at 10 Hz (θ10 Hz) and 15 kHz (θ15 kHz) to evaluate the coating performance and found that θ10 Hz showed a good correlation with the degradation of polymer coatings. The phase angle at 15 kHz θ15 kHz indicates the state of polymer coating in the later stage of exposure.19 The changing rate of impedance, a parameter proposed by Xia et al., provides a good way to monitor the coating degradation and shows a good agreement with that of θ10 Hz.20 The changing rate of phase angle (CRPA) was employed by Bing et al., which exhibits the same tendency with θ10 kHz and θ10 Hz.21 Haruyama and Sudo proposed the breakpoint frequency fb, which is defined as the frequency when the phase angle equals to −45°.22 They suggested that a good relationship exists between the breakpoint frequency and the delamination of the polymer-coated metal system. The breakpoint frequency fb shifts to high values during exposure stemming from the increase in the delaminated area. However, the application of f–45° suffers from some serious limitations.23,24 The time constants are not distinguishable when the value of coating capacitance is similar to that of double-layer capacitance. The breakpoint frequency f–45° is not available when pore resistance is high and/or the minimum of the phase angle at high-frequency range is higher than −45°. Furthermore, the polymer coating cannot be viewed as the ideal capacitor with the penetration of the electrolyte. The dispersive number n of coating capacitance deviates from 1 to much lower value during exposure. The frequency f–45° can no longer be regarded as the breakpoint frequency.25 Moreover, the breakpoint frequency fEIS derived from fitting EIS spectra cannot be employed well onsite due to the dependence on fitting software and complicated fitting. Herein, it is essential to develop a rapid method with the consideration of the dispersive number n to monitor the coating degradation and determine the breakpoint frequency at the medium and later exposure stages.
The aim of the present work is to compare the degradation behavior of a polymer-coated metal system in H2SO4 solutions with different concentrations. EIS spectra will be interpreted by appropriate equivalent circuits. The parameters derived involving Rp, Cdl, Rct, θ10 kHz, θ10Hz, fEIS, f–45°, and fp will be used to monitor and analyze the coating performance. Meanwhile, the frequency fp extracted by the CRPA method with the consideration of dispersive number n will be used as a coating evaluation approach for the medium and later exposure stages. Delaminated area ratio α calculated by fp will be compared with those obtained by f–45° and fEIS.
2. Results and Discussion
2.1. Optical Microscopic Characterization
Figure 1a,b illustrates the surface morphology under an optical microscope after exposure to 0.1 mol/L and 0.5 mol/L H2SO4 solutions, respectively, at 50 °C for 7 days. The exposed areas are clearly distinct from the as-received part. The polymer coating exposed to 0.5 mol/L H2SO4 solution presents more minor blisters and pores than that exposed to 0.1 mol/L H2SO4 solution. These small visual defects on the surface perform as the conductive channels resulting in the deterioration of the polymer coating. Corrosive elements can reach to the metal substrate through these pathways and result in the electrochemical reaction at the polymer/metal interface. The failure stemming from chemical degradation is usually presented in the acid electrolyte.7 The polymer-coated metal system exhibits visible blisters when exposed to 1 mol/L H2SO4 solution, Figure 1c. A large amount of defects can be observed, which are much more than that of any other sample. These blisters are filled with electrolytes and are originated by the penetration of corrosive elements through the polymer coating.
Figure 1.
Optical graphs of the polymer coatings exposed to (a) 0.1 mol/L H2SO4 solution, (b) 0.5 mol/L H2SO4 solution, and (c) 1 mol/L H2SO4 solution for 7 days at 50 °C.
Once ions such as H+ ions reached the polymer/metal surface, anodic reactions would occur. The metal substrate would be corroded. The accumulation of corrosion products beneath the polymer coating can be analyzed by the micrographs of cross sections shown in Figure 2. No obvious corrosion products are illustrated with regard to the case of 0.1 mol/L H2SO4 solution. The zinc coating on the surface of steel is almost intact. However, it is noticeable that the polymer coatings exposed to 0.5 and 1 mol/L H2SO4 solution are blistered. Corrosion products beneath polymer coatings can be observed. Soluble zinc ions and hydrogen gas will be produced, resulting from the electrochemical reaction in an acidic environment when the aggressive ions arrive on the surface of the metal substrate.26 The zinc layer is partly damaged
![]() |
1 |
![]() |
2 |
Figure 2.
Cross sections of the polymer coatings exposed to (a) 0.1 mol/L H2SO4 solution, (b) 0.5 mol/L H2SO4 solution, and (c) 1 mol/L H2SO4 solution for 7 days at 50 °C.
2.2. EIS Measurements and Data Analysis
EIS spectra of the polymer-coated metal systems exposed to different solutions are presented in Figure 3. The impedance reduces with the increase of exposure time, revealing that the spectra are sensitive to the degradation of the system. At a very early stage, the modulus |Z| in the medium–low frequency range displayed very high values (>109 ohm·cm2) for all samples. Only one capacitive loop can be observed from the Bode plots, which indicates the excellent protective performance. Water and other corrosive elements penetrate into the coating and do not reach the surface of the metal. The typical equivalent circuit model A is applied to interpret the impedance spectra during this stage. The pore resistance Rp results from the ionic conducting pathways through the polymer coating.24
Figure 3.
Bode plots of polymer-coated metal systems exposed to (a) 0.1 mol/L H2SO4 solution, (b) 0.5 mol/L H2SO4 solution, and (c) 1 mol/L H2SO4 solution at 50 °C after the indicated exposure time.
As time elapsed, the electrochemical corrosion had to be taken into consideration with the arrival of water and corrosive ions at the polymer/metal interface. The modulus |Z| decreased remarkably from 109 ohm·cm2 to less than 108 ohm·cm2. The sample exposed to 1 mol/L H2SO4 solution dropped to 2 × 106 ohm·cm2 after exposure for 2 h. The impedance spectra present one capacitive loop for the sample exposed to 0.1 mol/L H2SO4 solution at this stage. In the Nyquist plot shown in Figure 4a, it consists of two overlapped semicircles due to the minor electrochemical reaction at polymer/metal interface. The polymer coating gradually weakened and micropores increased continuously with regard to the system, thereby model B, which indicates the homogeneous distribution of electrochemical reactions, was employed.
Figure 4.
Representative Nyquist plots of the polymer-coated metal systems exposed to (a,b) 0.1 mol/L H2SO4 solution, (c) 0.5 mol/L H2SO4 solution, and (d) 1 mol/L H2SO4 solution at 50 °C at the indicated exposure time.
After a long-term exposure, a variation of the impedance spectra at the low-frequency range can be observed. The equivalent circuit model B is no longer appropriate to fit the data. The representative Nyquist plots of the polymer-coated metal systems exposed to different solutions at 50 °C after longer exposure times are shown in Figure 4. A tail is observed in the range of low frequency. This can attribute to the existence of the diffusion process. The diffusion process may become a control procedure in faradic processes.17 Herein, model C including diffusion parts was employed to interpret the impedance spectra. The constant phase element Cdiff and resistance Rdiff are derived to describe the diffusion process. The diffusion behavior is usually not ideal Warburg impedance, resulting in a deviation of the dispersive number n for Cdiff from 0.5.17 Three time constants can be observed for the samples exposed to 0.5 and 1 mol/L H2SO4 solutions. The capacitive loops at high frequency indicate the polymer coating performance, which implies its deterioration in terms of the declining diameters. The tendency can be observed according to Figure 4. The decreasing semicircle in the range of medium to low frequency indicates the electrochemical reaction at the polymer/metal interface. Thereby, the diffusion process of ionic species at the interface emerged in Nyquist plots and shaped as a slope line or large arc at low frequency. Parameters can be further derived to elucidate the degradation process. More information on the diffusion process will not be discussed.
2.3. Evaluation of Polymer-Coated Metal System
Time dependence of parameters including Cc, Rp, Cdl, and Rct for the polymer-coated metal systems during exposure to different electrolytes at 50 °C is given in Figure 5. The coating capacitances tended to increase gradually and stabilized at a similar range of 10–10–10–9 F/cm2. A relationship exists between the interfacial delamination and the electrochemical parameters such as pore resistance Rp, double-layer capacitance Cdl, and charge transfer resistance Rct.13 For the case of 0.1 mol/L, Rp reduced from 1010 to 3 × 105 ohm·cm2 due to the formation of pathways. More pores can be observed in Figure 1 for the sample exposed to 0.5 mol/L. Rp dropped to only ca. 104 ohm·cm2. The sample exposed to 1 mol/L H2SO4 solution exhibits the lowest pore resistance and charge transfer resistance. Both of them illustrate the same tendency and decreased to about 2 × 103 ohm·cm2 at the end of exposure. The decrease of Rct and increase of Cdl indicate the extension of the delaminated area beneath the polymer coating with progressive degradation, while both of them are also influenced by the electrochemical reaction involving the zinc layer, iron substrate, and corrosion products. The double-layer capacitance of the sample exposed to 0.1 mol/L H2SO4 solution increased from 10–10 to 10–9 F/cm2 at first 24 h and stabilized till 66 h. Once the aggressive ions arrived on the surface of the metal substrate, soluble zinc ions and hydrogen gas would be produced, resulting from the electrochemical reaction expressed by eqs 1 and 2 in an acidic environment. The reaction can further take place yielding the corrosion products according to eq 3
![]() |
3 |
Figure 5.
Time dependence of (a) Cc, (b) Rp, (c) Cdl, and (d) Rct for polymer-coated metal systems during the exposure to 0.1 mol/L H2SO4, 0.5 mol/L H2SO4, and 1 mol/L H2SO4 solutions at 50 °C.
The double-layer capacitance at the polymer/metal interface climbed to 10–7 F/cm2 at 80 h, which is much higher than the coating capacitance.13Cdl increased gradually and reached to 2 × 10–6 and 1 × 10–5 F/cm2 in the case of 0.5 and 1 mol/L H2SO4 solutions, which contain higher H+ ion concentration. The corrosion products generated through the above reactions were soluble and would further fill in the blisters during the measurement.
To obtain more detailed information about the deterioration, the parameters derived from EIS spectra including θ10 Hz and θ10 kHz are employed. Figure 6 presents the time dependence of θ10 Hz and θ10 kHz during exposure to different solutions at 50 °C for the polymer-coated metal system. The phase angle at 10 Hz θ10 Hz representing the characteristic of lower delaminated area is no longer appropriate to evaluate the degradation of the polymer-coated metal system. All of them fall into a low value around 10° at the very early stage and kept in a constant. The phase angle seems impossible to evaluate the degradation degree and ranking for other samples with higher delaminated area ratio α. The phase angle θ10 Hz for 0.5 and 1 mol/L increased slightly with the exposure time prolongation, which might be explained by the formation of corrosion products. The phase angle at 10 kHz shown in Figure 6b remains high at 60° when the sample was exposed to 0.1 mol/L H2SO4 solution, which presents an excellent performance for protection. The variation of θ10 kHz indicates that the delaminated area ratio is higher due to the sensitivity to polymer coating deterioration.27 θ10 kHz reduces to only 15 and 5° with the development of degradation for the case of 0.5 and 1 mol/L H2SO4 solution, respectively. The tendency of the delaminated area ratio calculated by fEIS is consistent with that of θ10 kHz. Herein, θ10 kHz can add substantially to our understanding on the degradation process at this stage, while the relationship between α and θ10 kHz for the polymer-coated metal systems is required to be further clarified. Meanwhile, the deviation of dispersive number n due to the penetration of the electrolyte should be taken into consideration.
Figure 6.
Time dependence of (a) θ10 Hz and θ10 kHz compared with delaminated area ratio for polymer-coated metal systems exposed to (b) 0.1 mol/L H2SO4 solution, (c) 0.5 mol/L H2SO4 solution, and (d) 1 mol/L H2SO4 solution during the exposure to different solutions at 50 °C.
The frequency fp obtained by the CRPA method is applied to shed light on the evolution of the delaminated area. Figure 7 presents the Bode plots of the changing rate of phase angle for the polymer-coated metal system exposed to various solutions at 50 °C. The smoothing curves of data points are displayed to guide the eye. The semicircles are overlapped and exhibit one capacitive loop due to the small electrochemical reaction area at the polymer/metal interface during this exposure period, which results in only one peak. The peak at the mid–low frequency region with the fp of 10 Hz at 121 min migrated to the mid–high frequency region with that of 121 Hz at 24.5 h in the case of 0.1 mol/L H2SO4 solution. This indicates the continuous extension of delaminated area at the polymer/metal interface. The value of d(θ)/d(log f) is associated with the dispersive number n. The frequency fp derived from the Bode plot of the phase angle stabilizes at 250 Hz at the end of exposure. Only one peak can be observed as same as the circumstance of 0.5 and 1 mol/L during the initial stage; fp shifted to 800 Hz at 605 min and 1000 Hz at 201 min with the degradation of the system. Two semicircles are distinguishable with the prolongation of exposure. The first peak at the high-frequency range corresponds to the component of polymer coating including coating capacitance Cc and pore resistance Rp in parallel. Therefore, the frequency fp in high-frequency range can be used to evaluate the delaminated area during the late stage, which reaches about 5.8 × 104 Hz at 48 h.
Figure 7.
Bode plots of the changing rate of the phase angle for the polymer-coated metal systems exposed to (a) 0.1 mol/L H2SO4 solution, (b) 0.5 mol/L H2SO4 solution, and (c) 1 mol/L H2SO4 solution during exposure to different solutions at 50 °C.
The variation of delaminated area ratio α calculated by the frequencies, which are extracted from the equivalent circuit (fEIS) obtained at −45°(f–45°) and derived according to the CRPA method (fp) for the polymer-coated metal system exposed to different solutions, is compared in Figure 8. Breakpoint frequency f–45° cannot be obtained from Bode plot for the system with nondistinguishable time constants between the polymer coating and electrochemical reaction, which stems from the limitation of measurement.22 It is noteworthy that the ignorance of dispersive number n would lead to the wrong estimation. The delaminated area ratio α calculated by f–45° increased from a low value to 1 × 10–2 at 160 h, which is 2.5 times larger than that calculated by fEIS and fp with respect to the case of 0.1 mol/L. The breakpoint frequency extracted from equivalent circuit fEIS exhibits a good agreement with fp. The same result can be obtained in the case of 0.5 mol/L. An obvious difference exists between α calculated by f–45° and fEIS after 38 h. The sample exposed to 0.5 mol/L H2SO4 solution at 50 °C for 7 days presents no remarkable blisters under the observation of optical microscope, the delaminated area ratio α defined by fEIS and fp is equal to 0.45, but 0.74 according to f–45°. α calculated by fEIS for the case of 1 mol/L H2SO4 solution increased to 0.56 at 48 h consistent with fp, which is overestimated by f–45°. After that, the breakpoint frequency is higher than 100 kHz, which is out of the measurement range and not accurate due to the limitation of the instrument. The application of f–45° neglects the dispersive number n and leads to wrong estimation, while the CRPA method involving fp can contribute to evaluate the performance and add our understanding for the interfacial delamination. The frequency fp can be viewed as a rapid approach to shed light on the degradation of the polymer-coated metal systems without complicated EIS fitting at the medium and late exposure stages. More work is underway.
Figure 8.
Time dependence of α calculated by fEIS, f–45°, and fp for the polymer-coated metal systems during exposure to (a) 0.1 mol/L H2SO4 solution, (b) 0.5 mol/L H2SO4 solution, and (c) 1 mol/L H2SO4 solution during the exposure to different solutions at 50 °C.
3. Conclusions
This study evaluated the electrochemical behavior and interfacial delamination of a polymer-coated metal system exposed to H2SO4 solutions with different concentrations for 7 days at 50 °C by EIS measurement. The following conclusions can be drawn.
Blisters and large-area delamination were observed upon exposure to H2SO4 solutions. Typical equivalent circuit models are employed to analyze EIS spectra and the models present a good fitting agreement with experiment data for samples measured at 50 °C. In the initial stage, the equivalent circuit only consists of the coating capacitance in parallel with the coating resistance. Following this, the electrochemical reaction occurs at the polymer/metal interface. As the exposure time elapsed, corrosion products accumulated on the surface of the metal substrate and hindered the corrosion process with mass transfer.
Corrosion elements penetrating into the polymer coating with increase in exposure time lead to the decrease of pore resistance and increase of double-layer capacitance. Pore resistances drop from about 1 × 1010 to 3 × 105 and 2 × 103 ohm·cm2 before and after aging in 0.5 and 1 mol/L H2SO4 solutions at 50 °C for 7 days, respectively. The phase angle at 10 Hz θ10 Hz of all samples falls into a low value around 10° and is not appropriate to demonstrate the degradation in the case of higher delamination area ratio α. The tendency of α calculated from fEIS is consistent with that of θ10 kHz in the case of higher delaminated area.
The frequency f–45° can be no longer viewed as the breakpoint frequency with the deviation of dispersive number n. The ignorance of n can lead to the wrong estimation of the delaminated area. The delaminated area ratios α calculated by f–45° amount to 0.74 and 0.72 for the case of 0.5 mol/L at 160 h and 1 mol/L at 48 h, which are much higher than that obtained by fEIS with the values of 0.45 and 0.56, respectively. The frequency fp extracted by the CRPA method is derived. fEIS derived by fitting shows a good agreement with fp. The frequency fp can be viewed as a rapid approach to shed light on the degradation of the polymer-coated metal systems at the medium and late exposure stages.
4. Experimental Section
4.1. EIS Measurements
A commercial epoxy coating on the galvanized steel substrate with the coating thickness of about 196.9 ± 22.5 μm was provided by a company. The plate with the substrate thickness of 3 mm was cut into the size of 80 mm × 80 mm and kept in air for 24 h according to ISO 16773-2: 2016 (E) before measurements. An electrochemical workstation (VersaSTAT 4, AMETEK) was used for all of the electrochemical measurements. The electrochemical cell was modified from a flat cell K235. The EIS spectra were measured at 50 °C in situ with a two-electrode setup using a platinum grid counter electrode and the sample with an exposed area of 10 cm2 as working electrode. The cell was filled with H2SO4 solutions with different concentrations. The degradation process is fast and requires rapid scanning during the very early stage. Herein, the frequency range was 105–1 Hz to obtain more data in a short time. As the time elapsed, the applied frequency range was 105–10–2 Hz with a signal amplitude of 50 mV. Analysis of electrochemical impedance spectra was conducted by the software Zview (Version 3.5, Scribner Associates, Inc.).
Model A shown in Figure 9a is proposed to interpret the EIS spectra in the stage without the electrochemical process. Constant phase elements (CPE) are introduced to obtain more accurate fitting results considering the nonideal capacitance behavior for Cc and Cdl in the system, which is expressed as28,29
![]() |
4 |
where Y0 is the CPE constant with the units of F·cm–2 s(n–1), j is the imaginary number, ω is the angular frequency, and n is a value indicating the deviation from purely capacitive behavior (0 ≤ n ≤ 1).28−30 Capacitance is nearly equal to Y0 of the CPE with n ≈ 1. Along with the exposure time, the polymer coating gradually weakened and pores increased continuously, and the distribution of electrochemical reactions is roughly homogeneous. Model B presented in Figure 9b is used to describe the electrochemical reaction. Herein, the electrochemical component is illustrated as a capacitance (double-layer capacitance Cdl) in parallel with a resistance (charge transfer resistance Rct).10−12 At the medium and last stages of exposure, the presence of corrosion products can give rise to the diffusion process, which might be a control procedure in the electrochemical reaction. Model C including the diffusion capacitance (Cdiff) and diffusion resistance (Rdiff) is established to fit the spectra.8
Figure 9.
Equivalent circuits used for the impedance analysis of a polymer-coated metal system exposed to corrosive environments.
Coating capacitance Cc and pore resistance Rp derived from equivalent circuits can be used to calculate the breakpoint frequency fb, which exhibits a good correlation with the delaminated area.31 Herein, the breakpoint frequency fb extracted from equivalent circuit is defined as fEIS. The higher the fEIS, the larger the delaminated area at the coating/metal interface.32 The extent of delamination can be determined experimentally from the breakpoint frequency fEIS, which is given by
![]() |
5 |
α = Ad/A is the delaminated area ratio. Ad and A represent the equivalent delaminated area and whole exposure area, respectively. The constant K depends only on the coating parameters ρ and ε. It is independent of coating thickness
![]() |
6 |
εepo = 4 and ρ = 6.27 × 106 ohm·cm according to the literature.33,34K can be approximately regarded as a constant according to the parameters above.32,35
4.2. Frequency fp from the Changing Rate of Phase Angle
The dispersive number n of coating capacitance deviates from 1 to much lower value during the late exposure due to the water uptake behavior and interfacial reactions, which should be taken into consideration for the calculation of fb. In this case, the frequency corresponding to −45° (f–45°) can no longer be viewed as the breakpoint frequency.25 Herein, the frequency corresponding to the first peak at high-frequency range (fp) obtained by the changing rate of the phase angle (CRPA) method is derived to monitor the coating degradation and determine the breakpoint frequency. The pore resistance Rp is usually much higher than the electrolyte resistance Re. Herein, the electrochemical equivalent circuit for the polymer coating can be represented as a resistance R in parallel with coating capacitance C. The real part Y′ and imaginary part Y″ of admittance about coating capacitance can be expressed by25
![]() |
7 |
![]() |
8 |
Therefore, the admittance Y of the polymer coating component
![]() |
9 |
And the impedance Z of polymer coating component
![]() |
10 |
The real part Zre and imaginary part Zim of impedance are demonstrated by eqs 11 and 12, respectively.
![]() |
11 |
![]() |
12 |
Hence, the phase angle can be expressed by
![]() |
13 |
The changing rate of the phase angle q satisfying eq 14 is sensitive to reflect the variation of the phase angle, especially in the range of high frequency with less interference from interfacial reaction.
![]() |
14 |
where a and b represent RY0·(2π)n·sin(nπ/2) and RY0·(2π)n·cos(nπ/2), respectively. The frequency at the first peak fp in the range of high frequency can be calculated when the derivative of q versus log10 f equals to zero, as shown in eqs 15 and 16
![]() |
15 |
![]() |
16 |
At this time, the changing rate of the phase angle q can be calculated by
![]() |
17 |
The data analysis for extracting fp is simple with the help of the function in Microsoft Excel. The frequency fp indicates the characteristic of polymer coating and can be viewed as a parameter to evaluate the delamination area with the consideration of dispersive number n. The changing rate of phase angle q at the frequency fp can also be used to estimate the value of n when the time constants of the polymer coating and electrochemical process are distinguishable.
Acknowledgments
C.F. thanks the China Scholarship Council for a Ph.D. Fellowship (No. 201506450019) and the Dongying Science and Technology Development Foundation (DJ2020016). J.S. acknowledges the financial support from the German Research Foundation (DFG, SH802/2-1).
The authors declare no competing financial interest.
References
- Akafuah N. K.; Poozesh S.; Salaimeh A.; Patrick G.; Lawler K.; Saito K. Evolution of the automotive body coating process—A review. Coatings 2016, 6, 24 10.3390/coatings6020024. [DOI] [Google Scholar]
- Lacombre C. V.; Trinh D.; Bouvet G.; Feaugas X.; Mallarino S.; Touzain S. Influence of pigment on the degradation of anticorrosion polymer coatings using a thermodynamic analysis of electrochemical impedance spectroscopy data. Electrochim. Acta 2017, 234, 7–15. 10.1016/j.electacta.2017.03.050. [DOI] [Google Scholar]
- Hao Y.; Liu F.; Han E. H.; Anjum S.; Xu G. B. The mechanism of inhibition by zinc phosphate in an epoxy coating. Corros. Sci. 2013, 69, 77–86. 10.1016/j.corsci.2012.11.025. [DOI] [Google Scholar]
- Kulkarni A.; Dasari H. In Current Status of Methods Used in Degradation of Polymers: A Review, MATEC Web of Conferences; EDP Sciences, 2018; p 02023.
- Deshpande P. P.; Jadhav N. G.; Gelling V. J.; Sazou D. Conducting polymers for corrosion protection: a review. J. Coat. Technol. Res. 2014, 11, 473–494. 10.1007/s11998-014-9586-7. [DOI] [Google Scholar]
- Shi J. M.; Pries H.; Stammen E.; Dilger K. Chemical pretreatment and adhesive bonding properties of high-pressure die cast aluminum alloy: AlSi10MnMg. Int. J. Adhes. Adhes. 2015, 61, 112–121. 10.1016/j.ijadhadh.2015.06.002. [DOI] [Google Scholar]
- Sanchez-Amaya J. M.; Osuna R. M.; Bethencourt M.; Botana F. J. Monitoring the degradation of a high solids epoxy coating by means of EIS and EN. Prog. Org. Coat. 2007, 60, 248–254. 10.1016/j.porgcoat.2007.07.020. [DOI] [Google Scholar]
- Ding R.; Jiang J.; Gui T. Study of impedance model and water transport behavior of modified solvent-free epoxy anticorrosion coating by EIS. J. Coat. Technol. Res. 2016, 13, 501–515. 10.1007/s11998-015-9769-x. [DOI] [Google Scholar]
- Yuan X.; Yue Z. F.; Chen X.; Wen S. F.; Li L.; Feng T. EIS study of effective capacitance and water uptake behaviors of silicone-epoxy hybrid coatings on mild steel. J. Coat. Technol. Res. 2015, 86, 41–48. 10.1016/j.surfcoat.2014.11.065. [DOI] [Google Scholar]
- Farag A. A.; Kabel K. I.; Elnaggar E. M.; Al-Gamal A. G. Influence of polyaniline/multiwalled carbon nanotube composites on alkyd coatings against the corrosion of carbon steel alloy. Corros. Rev. 2017, 35, 85–94. 10.1515/corrrev-2017-0049. [DOI] [Google Scholar]
- Khoshkhou Z.; Torkghashghaei M.; Baboukani A. R. Corrosion inhibition of henna extract on carbon steel with hybrid coating TMSM-PMMA in HCL solution. Open J. Synth. Theory Appl. 2018, 7, 1–16. 10.4236/ojsta.2018.71001. [DOI] [Google Scholar]
- Xu J.; Zhang Y.; Zhang D.; Tang Y.; Cang H. Electrosynthesis of PAni/PPy coatings doped by phosphotungstate on mild steel and their corrosion resistances. Prog. Org. Coat. 2015, 88, 84–91. 10.1016/j.porgcoat.2015.06.024. [DOI] [Google Scholar]
- Amirudin A.; Thieny D. Application of electrochemical impedance spectroscopy to study the degradation of polymer-coated metals. Prog. Org. Coat. 1995, 26, 1–28. 10.1016/0300-9440(95)00581-1. [DOI] [Google Scholar]
- Kartsonakis I. A.; Balaskas A. C.; Koumoulos E. P.; Charitidis C. A.; Kordas G. C. Incorporation of ceramic nanocontainers into epoxy coatings for the corrosion protection of hot dip galvanized steel. Corros. Sci. 2012, 57, 30–41. 10.1016/j.corsci.2011.12.037. [DOI] [Google Scholar]
- Xue X.; Lu J. Electrochemical Impedance Spectroscopy Investigation of a Polyurethane Coating on Bridge 16Mnq Steel Surface. Int. J. Electrochem. Sci. 2017, 12, 3179–3187. 10.20964/2017.04.19. [DOI] [Google Scholar]
- Kefallinou Z.; Lyon S. B.; Gibbon S. R. A bulk and localised electrochemical assessment of epoxy-phenolic coating degradation. Prog. Org. Coat. 2017, 102, 88–98. 10.1016/j.porgcoat.2016.04.042. [DOI] [Google Scholar]
- Jie L.; Li X. B.; Wang J.; Luo T. Y.; Wang X. M. Studies of impedance models and water transport behaviours of epoxy coating at hydrostatic pressure of seawater. Prog. Org. Coat. 2013, 76, 1075–1081. 10.1016/j.porgcoat.2013.03.006. [DOI] [Google Scholar]
- Mahdavian M.; Attar M. M. Another approach in analysis of paint coatings with EIS measurement: phase angle at high frequencies. Corros. Sci. 2006, 48, 4152–4157. 10.1016/j.corsci.2006.03.012. [DOI] [Google Scholar]
- Zuo Y.; Pang R.; Li W.; Xiong J. P.; Tang Y. M. The evaluation of coating performance by the variations of phase angles in middle and high frequency domains of EIS. Corros. Sci. 2008, 50, 3322–3328. 10.1016/j.corsci.2008.08.049. [DOI] [Google Scholar]
- Xia D. H.; Song S. Z.; Wang J. H.; Bi H. C.; Han Z. W. Fast evaluation of degradation degree of organic coatings by analyzing electrochemical impedance spectroscopy data. Trans. Tianjin Univ. 2012, 18, 15–20. 10.1007/s12209-012-1752-3. [DOI] [Google Scholar]
- Bing L.; Xu A. T.; Liang Y. S.; Huang Z.; Qiao Z. X.; Xia D. H.; Zhang S. S.; Li Z. C.; Zhang F.; Chen P. Evaluation on protective performance of organic coatings by analyzing the change rate of phase angle at high frequency. Int. J. Electrochem. Sci. 2012, 7, 8859–8868. [Google Scholar]
- Haruyama S.; Sudo S. Electrochemical impedance for a large structure in soil. Electrochim. Acta 1993, 38, 1857–1865. 10.1016/0013-4686(93)80307-L. [DOI] [Google Scholar]
- Deflorian F.; Fedrizzi L.; Bonora P. L. Determination of the reactive area of organic coated metals using the breakpoint method. Corrosion 1994, 50, 113–119. 10.5006/1.3293499. [DOI] [Google Scholar]
- Tsai C. H.; Mansfeld F. Determination of coating deterioration with EIS: Part II. Development of a method for field testing of protective coatings. Corrosion 1993, 49, 726–737. 10.5006/1.3316106. [DOI] [Google Scholar]
- Cao C. N.; Zhang J. Q.. An Introduction to Electrochemical Impedance Spectroscopy; SciPress: Shanghai, 2002. [Google Scholar]
- Zhang H.; Li X. G.; Du C. W.; Qi H. B. Corrosion behavior and mechanism of the automotive hot-dip galvanized steel with alkaline mud adhesion. Int. J. Miner., Metall. Mater. 2009, 16, 414–421. 10.1016/S1674-4799(09)60073-X. [DOI] [Google Scholar]
- Attar M. M. Investigation on zinc phosphate effectiveness at different pigment volume concentrations via electrochemical impedance spectroscopy. Electrochim. Acta 2005, 50, 4645–4648. 10.1016/j.electacta.2005.02.015. [DOI] [Google Scholar]
- Zhang J. T.; Hu J. M.; Zhang J. Q.; Cao C. N. Studies of water transport behavior and impedance models of epoxy-coated metals in NaCl solution by EIS. Prog. Org. Coat. 2004, 51, 145–151. 10.1016/j.porgcoat.2004.08.001. [DOI] [Google Scholar]
- Zhu C.; Xie R.; Xue J.; Song L. Studies of the impedance models and water transport behaviors of cathodically polarized coating. Electrochim. Acta 2011, 56, 5828–5835. 10.1016/j.electacta.2011.04.068. [DOI] [Google Scholar]
- Bonora P. L.; Deflorian F.; Fedrizzi L. Electrochemical impedance spectroscopy as a tool for investigating underpaint corrosion. Electrochim. Acta 1996, 41, 1073–1082. 10.1016/0013-4686(95)00440-8. [DOI] [Google Scholar]
- Souto R. M.; Fox V.; Laz M. M.; Gonzlez S. Electrochemical impedance spectroscopy investigation of the corrosion at metallic substrates covered by organic coatings. J. Adhes. Sci. Technol. 2000, 14, 1321–1330. 10.1163/156856100742212. [DOI] [Google Scholar]
- Liu X. W.; Xiong J. P.; Lv Y. W.; Zuo Y. Study on corrosion electrochemical behavior of several different coating systems by EIS. Prog. Org. Coat. 2009, 64, 497–503. 10.1016/j.porgcoat.2008.08.012. [DOI] [Google Scholar]
- Mansfeld F. Use of electrochemical impedance spectroscopy for the study of corrosion protection by polymer coatings. J. Appl. Electrochem. 1995, 25, 187–202. 10.1007/BF00262955. [DOI] [Google Scholar]
- Mansfeld F.; Tsai C. H.; Shih H. In Determination of Coating Delamination and Corrosion Damage with EIS, Proceedings of Symposium on Advances in Corrosion Protection by Organic Coatings, Pennington, 1989; pp 228–240.
- Li Y. Y.; Yang Z. Z.; Qiu H. X.; Dai Y. G.; Zheng Q. B.; Li J.; Yang J. H. Self-aligned graphene as anticorrosive barrier in waterborne polyurethane composite coatings. J. Mater. Chem. A 2014, 2, 14139–14145. 10.1039/C4TA02262A. [DOI] [Google Scholar]