Improved unsupervised physics‐informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients

Misha P T Kaandorp 1,2,3,, Sebastiano Barbieri 4, Remy Klaassen 5, Hanneke W M van Laarhoven 5, Hans Crezee 1, Peter T While 2,3, Aart J Nederveen 1, Oliver J Gurney‐Champion 1
PMCID: PMC8362093  PMID: 34105184

Abstract

Purpose

Earlier work showed that IVIM‐NETorig, an unsupervised physics‐informed deep neural network, was faster and more accurate than other state‐of‐the‐art intravoxel‐incoherent motion (IVIM) fitting approaches to diffusion‐weighted imaging (DWI). This study presents a substantially improved version, IVIM‐NEToptim, and characterizes its superior performance in pancreatic cancer patients.

Method

In simulations (signal‐to‐noise ratio [SNR] = 20), the accuracy, independence, and consistency of IVIM‐NET were evaluated for combinations of hyperparameters (fit S0, constraints, network architecture, number of hidden layers, dropout, batch normalization, learning rate), by calculating the normalized root‐mean‐square error (NRMSE), Spearman’s ρ, and the coefficient of variation (CVNET), respectively. The best performing network, IVIM‐NEToptim was compared to least squares (LS) and a Bayesian approach at different SNRs. IVIM‐NEToptim’s performance was evaluated in an independent dataset of 23 patients with pancreatic ductal adenocarcinoma. Fourteen of the patients received no treatment between two repeated scan sessions and nine received chemoradiotherapy between the repeated sessions. Intersession within‐subject standard deviations (wSD) and treatment‐induced changes were assessed.

Results

In simulations (SNR = 20), IVIM‐NEToptim outperformed IVIM‐NETorig in accuracy (NRMSE(D) = 0.177 vs 0.196; NMRSE(f) = 0.220 vs 0.267; NMRSE(D*) = 0.386 vs 0.393), independence (ρ(D*, f) = 0.22 vs 0.74), and consistency (CVNET(D) = 0.013 vs 0.104; CVNET(f) = 0.020 vs 0.054; CVNET(D*) = 0.036 vs 0.110). IVIM‐NEToptim showed superior performance to the LS and Bayesian approaches at SNRs < 50. In vivo, IVIM‐NEToptim showed significantly less noisy parameter maps with lower wSD for D and f than the alternatives. In the treated cohort, IVIM‐NEToptim detected the most individual patients with significant parameter changes compared to day‐to‐day variations.

Conclusion

IVIM‐NEToptim is recommended for accurate, informative, and consistent IVIM fitting to DWI data.

Keywords: deep neural network, diffusion‐weighted magnetic resonance imaging, intravoxel incoherent motion, IVIM, pancreatic cancer, unsupervised physics‐informed deep learning

1. INTRODUCTION

The intravoxel incoherent motion (IVIM) model1 for diffusion‐weighted imaging (DWI) shows great potential for estimating predictive and prognostic cancer imaging biomarkers.2, 3, 4, 5 In the IVIM model, DWI signal is described by a bi‐exponential decay, of which one component is attributed to conventional molecular diffusion and the other to the incoherent bulk motion of water molecules, typically credited to capillary blood flow. Hence, IVIM simultaneously provides information on diffusion (D; diffusion coefficient), capillary microcirculation (D*; pseudo‐diffusion coefficient), and the perfusion fraction (f) without the use of a contrast agent.6, 7, 8 However, despite IVIM’s great potential,2, 3, 4, 5 it is rarely used clinically. Two major hurdles preventing routine clinical use of IVIM are its poor image quality and the long fitting time.9, 10, 11 Tackling these shortcomings will help toward wider use of IVIM.12

Currently, IVIM is often fitted using the conventional least squares (LS) algorithm. However, more accurate alternative approaches have been suggested.9 Until recently, Bayesian algorithms for IVIM fitting13 were most promising regarding inter‐subject variability,9 precision, accuracy,14 and smooth parameter maps, suggesting less noise.15 Conversely, Bayesian approaches are substantially slower (9 × 10−2 s/vox11) than the already slow LS approach (8 × 10−3 s/vox11). Furthermore, Bayesian approaches may lead to biased perfusion estimates of the IVIM model.16

Recently, a promising alternative for IVIM fitting was introduced: estimating IVIM parameters with deep neural networks (DNNs). Initially, Bertleff et al17 introduced a supervised DNN for IVIM parameter estimation, in which the network was trained on simulated data for which the underlying parameters were known. However, the strong assumption of simulated training and test data being identically distributed could limit the network’s performance in vivo, where noise behaves less ordered. We solved this shortcoming in earlier work,11 where we used unsupervised physics‐informed deep neural networks (PI‐DNNs).18, 19 PI‐DNNs formulate a physics‐informed‐loss‐function that finds learned parameters through an iterative process. In this case, the PI‐DNN used consistency between the predicted signal from the IVIM model and the measured signal as a loss term in the DNN. This resulted in an unsupervised PI‐DNN capable of training directly on patient data with no ground truth: IVIM‐NETorig. We demonstrated in both simulations and volunteer analysis that IVIM‐NETorig is superior to the conventional LS approach and even performs (marginally) better than the Bayesian approach. Furthermore, IVIM‐NETorig’s fitting times were substantially lower (4 × 10−6 s/vox11) than the LS and Bayesian approaches. However, that proof of principle IVIM‐NET study did not explore many hyperparameters and focused on volunteer data.

In this work, we hypothesize that IVIM‐NETorig can be improved by exploring the architecture of the network, its training features and other hyperparameters. Hence, we characterized the performance of IVIM‐NET for different hyperparameter settings by assessing the accuracy, independence, and consistency of the estimated IVIM parameters in simulated IVIM data. Finally, we compared the performance of our optimized IVIM‐NET to the LS approach and a Bayesian approach in patients with pancreatic ductal adenocarcinoma (PDAC) receiving neoadjuvant chemoradiotherapy (CRT) in terms of image quality, parameter to noise ratio, test‐retest reproducibility, and sensitivity to treatment effects.

2. METHODS

2.1. IVIM‐NET

We initially implemented the original PI‐DNN (IVIM‐NETorig)11 in Python 3.8 using PyTorch 0.4.1.20 The input layer consisted of neurons that took the normalized DWI signal S(b)/S(b = 0) as input, where S(b) is the measured signal at diffusion weighting b (b value). The input layer was followed by three fully connected hidden layers. Each hidden layer had several neurons equal to the number of measurements (b values and the number of repeated measures) and each neuron, in turn, contained an exponential linear unit activation function.21 The output layer of the network consisted of the three IVIM parameters (D, f, D*). To enforce the output layer to predict these IVIM parameters, two steps were taken. First, the absolute activation function was taken of the neuron’s output (X) to constrain the predicted parameters, for example, to compute D:

D=X1. (1)

Second, a physics‐based loss function was introduced that computed the mean squared error between the measured input signal, S(b), and the predicted IVIM signal Snet(b), which was obtained by inserting the predicted output parameters into the normalized IVIM model. Hence:

L=1BbBSbSb=0Snetb2, (2)

with

Snetb=febD+1febD, (3)

where B is the total number of image acquisitions.

Next, we evaluated whether seven novel hyperparameters (Table 1; Figure 1) of IVIM‐NET improved fitting results. First, instead of fixing S0, we added S0 as an additional output parameter, to allow the system to correct for noise in S(b = 0). Second, to restrict parameter values to physiologically plausible ranges, scaled sigmoid activation functions instead of absolute activation functions were used to constrain the predicted parameters (Table 1), for example, to compute D:

D=Dmin+sigmoidX1DmaxDmin, (4)

where D min and D max are the fit boundaries. Bound intervals of the sigmoid activation functions were chosen 60% wider (30% at each side) than the fit boundaries of the LS and Bayesian approaches (specified in section 2.2 below) to compensate for decreasing gradients at the asymptotes of the sigmoid function. Third, we varied the number of hidden layers between one and nine. Fourth, we used dropout regularization22 in all hidden layers except for the last one. Dropout randomly removes a set percentage of network‐weights each iteration during training. Fifth, we used batch normalization,23 which normalizes the input by re‐centering and re‐scaling, and, consequently, preserves the representation ability of the network. Sixth, to reduce unwanted correlation between estimated parameter values, we implemented an alternative network architecture in which parameter values were predicted, in parallel, by independent sub‐networks (Table 1; Figure 1). Furthermore, we evaluated different learning rates (LR) of the Adam optimizer,24 ranging from 1 × 10−5 to 3 × 10−2, and with constant β = (0.9, 0.999).

TABLE 1.

Hyperparameter settings for training IVIM‐NET, including the settings for IVIM‐NETorig and IVIM‐NEToptim

Hyperparameter Values IVIM‐NETorig IVIM‐NEToptim
Fit S0 True, False False True
Constraints Sigmoid, Absolute Absolute Sigmoid
Parallel networks True, False False True
Number of hidden layers 1,2 3, 4, 5, 6, 7, 8, 9 3 2
Dropout regularization 0%, 10%, 20%, 30% 0% 10%
Batch normalization True, False False True
Learning rate 1 × 10−5, 3 × 10−5, 1 × 10−4, 3 × 10−4, 1 × 10−3, 3 × 10−3, 1 × 10−2, 3 × 10−2 1 × 10−3 3 × 10−5

FIGURE 1.

FIGURE 1

Representation of the PI‐DNN with different hyperparameter options (Table 1). In this example, the input signal, consisting of the measured DWI signal, is fedforward either through a parallel network design where each parameter is predicted by a separate fully connected set of hidden layers (A) or the original single fully connected network design (B). The blue circles indicate an example of randomly selected neurons for dropout. In this example, the output layer consists of four neurons with either absolute (Equation 1) or sigmoid activation functions (Equation 4) whose values correspond to the IVIM parameters. Subsequently, the network predicts the IVIM signal (Equation 3), which is used to compute the loss function (Equation 2). With the loss function, the network trains the PI‐DNN to give good estimates of the IVIM parameters

In traditional deep learning, training and evaluation are done on separate datasets, but as this is an unsupervised DNN approach, training was done on the same data as evaluation.11, 25 So, for simulations, these were simulated data, and in vivo, these were in vivo data. 90% of the data were used for training, and 10% of the data were used for validation. Early stopping occurred when the validation loss did not improve over 10 consecutive training epochs. Given the large amount of training data and the limited number of network parameters, each epoch consisted of only 500 random batches. So, effectively the network saw 500 × 128 IVIM curves in between validations.

2.2. Simulations: characterization and optimization

100,000 IVIM curves were simulated to investigate the effects of different hyperparameters on the accuracy, independence, and consistency of the estimated IVIM parameters. DWI signals were simulated based on Equation 3 with S 0 = 1, 11 b values (b = 0, 5, 10, 20, 30, 40, 60, 150, 300, 500, and 700 s/mm2), and pseudorandom uniformly sampled values of D: 0.5 × 10−3 to 3 × 10−3 mm2/s, f: 5 to 55%, and D*: 10 × 10−3 to 100 × 10−3 mm2/s. These ranges were slightly broader than the typical values found in abdominal IVIM.26 Random Rician noise in the form of complex Gaussian noise was added to the curves with predefined signal‐to‐noise ratio (SNR) levels (constant noise amplitude over b values; SNR defined at b = 0 as S(b = 0)/σ, with σ the SD of the Gaussians).27

Accuracy was assessed as the normalized root‐mean‐square error (NRMSE) between the ground truth parameter values and the estimated IVIM parameters.

Independence of the parameter estimates was assessed by the Spearman rank correlation coefficients (ρ) between all parameter pairs. As the simulated data were independent and random, a ρ should be 0. The absolute value of ρ was taken, as both positive and negative deviations from zero are equally undesirable. Some networks always returned the same value for D*, independent of the input data (Supporting Information Figure S1, which is available online). For such cases, ρ is technically undefined. As these cases are undesirable ρ was set to 1.

As training a DNN is a stochastic process, training on the same dataset results in different final network‐weights, and consequently, different predictions on the same data. To assess the consistency of estimated parameter values, each network variant was trained 50 times on identical data, where each repeat had a new random initialization, dropout, and batch selection. The normalized coefficient of variation per parameter over the repeated trainings (CVNET) was taken as a measure of the consistency:

CVNET=1x¯true1n×m1i=1nj=1mxi,jx¯i2, (5)

where true is the mean simulated IVIM parameter value, n the number of simulated curves, m the number of repeated trainings, xi,j is the j th repeated prediction of the i th simulated decay curve, i is the mean over the repeated m predictions of the i th simulated signal curve. As the LS and Bayesian approaches are deterministic, their CVNET was zero.

As a result of the repeated training, we obtained 50 values for the NRMSEs and ρ’s. Therefore, the median and interquartile ranges were reported.

As a baseline for comparison, we evaluated the IVIM parameters (D, f, D*) in IVIM‐NETorig, the LS and Bayesian approaches. We used the Levenberg‐Marquardt non‐linear algorithm for the LS fit.28, 29 For the Bayesian approach, we used the algorithm from previous work.11 For both the LS and Bayesian approaches, S0 was included as a fit parameter. The Bayesian approach used a data‐driven lognormal prior for D and D*, and a beta distribution for f and S0. The prior distributions were determined empirically by fitting these distributions to the results from the LS approach on the same dataset. The maximum a posteriori probability was used as an estimate of the IVIM parameters. The LS and Bayesian approaches were performed with fit boundaries of D: 0 × 10−3 to 5 × 10−3 mm2/s, f: 0 to 70%, D*: 5 × 10−3 to 300 × 10−3 mm2/s, and S0: 0.7 to 1.3.

After baseline characterization, IVIM‐NET was optimized by testing various combinations of the hyperparameters (Table 1; Figure 1). Previous studies reported reliable SNR values of IVIM in the abdomen between 10 and 40.30, 31, 32, 33 So, to simulate reliable abdominal IVIM signals, an SNR of 20 was chosen for hyperparameter evaluation. We trained the network on the simulated signals using every combination of the following options: fit S0 parameters, absolute or sigmoid constraints, parallel network, dropout, and batch normalization ‐ while fixing the number of hidden layers to three (used in IVIM‐NETorig, Table 1) and the LR to 1 × 10−4. In an exploratory phase, we found that reducing the LR from 1 × 10−3 (IVIM‐NETorig) to 1 × 10−4 was essential for obtaining networks with improvements in accuracy, independence, and consistency. Each network (ie, combination of hyperparameters) received a ranking in each of the nine performance measures (three metrics for three parameters), and these nine ranks were summed. Hence, the best possible summed rank is 9. The best performing network was then chosen by selecting the network with the lowest summed rank.

With the best options for the fit S0 parameters, constraints, parallel network, dropout, and batch normalization, we tested the performance of the network as a function of the LR and the number of hidden layers (Table 1). From those results, we finally selected the best performing optimized network by again selecting the lowest summed rank: IVIM‐NEToptim. IVIM‐NEToptim’s performance was then characterized and compared to the LS approach, Bayesian approach and IVIM‐NETorig for SNR values between 8 (low) and 100 (high).

2.3. Verification in patients with PDAC

We used two IVIM datasets of patients with PDAC to validate IVIM‐NEToptim's performance in vivo: one dataset to assess test‐retest reproducibility, and one to test whether we can detect treatment effects. Both studies were approved by our local medical ethics committee, and all patients gave written informed consent.

Both datasets (NCT01995240; NCT01989000) were published earlier.9, 34, 35 The first dataset consists of 14 patients with locally advanced or metastatic PDAC who underwent IVIM in two separate imaging sessions (average 4.5 days apart, range: 1‐8 days) with no treatment in‐between. The second dataset consisted of nine PDAC patients with (borderline) resectable PDAC who received CRT as part of the PREOPANC study36 where patients were scanned before and after CRT.

MRI data were acquired using a 3T MRI scanner (Ingenia, Philips, Best, The Netherlands). A respiratory triggered (navigator on liver dome) 2D multi‐slice diffusion‐weighted echo‐planar imaging was used with parameters: repetition time (TR) > 2200 ms (depending on respiration speed), echo time (TE) = 45 ms, flip angle (FA) = 90 deg, field of view (FOV) = 432 × 108 mm2, acquisition matrix = 144 × 34, 18 slices, slice thickness = 3.7 mm and 12 b values (directions): 0 (15), 10 (9), 20 (9), 30 (9), 40 (9), 50 (9), 75 (4), 100 (12), 150 (4), 250 (4), 400 (4), and 600 (16) mm2/s. Fat suppression was carried out with a gradient reversal during slice selection and spectral presaturation with inversion recovery. Diffusion gradient times were 10.1 ms with a delay between diffusion gradients onset of 22.6 ms.

DWI images were co‐registered to a reference volume consisting of a mean DWI image over all b values using deformable image registration in Elastix.37 A radiologist (10 y of experience in abdominal radiology) and researcher (4 y of experience in contouring pancreatic cancer) drew a region of interest (ROI) in the tumor in consensus. IVIM parameter maps of D, f and D* were derived using the LS approach, Bayesian approach, and IVIM‐NEToptim. Background voxels were removed automatically before fitting by removing voxels with S(b = 0) < 0.5 × median(S(b = 0)). Fitting was done without averaging over the diffusion directions. IVIM‐NEToptim was trained on all combined patient data. Values under 0 for D, f, and D* were considered not physiologic and set to 0, and for further statistics, values of D* were masked where f < 5% as D* only “exists” in perfused voxels. All computations were carried out on a single core of a conventional desktop computer (CPU: Intel Core i7‐8700 CPU at 3.20 GHz). The average fitting time of each algorithm was recorded.

First, the parameter maps were compared qualitatively in terms of feature clarity, and by visually assessing consistency of fit to the IVIM signal in pairs of neighboring voxels. For a quantitative comparison, the parameter to noise ratio (PNR) of the parameter maps was estimated in a homogeneous 2D ROI (>20 voxels) in the liver. PNR was defined as mean/STD of the homogenous ROIs and was calculated for each scan separately. We tested whether the difference in PNR between fit approaches was significant using paired t‐tests.

To determine clinical usefulness of IVIM‐NET, we investigated whether we could detect changes in parameter values throughout CRT by comparing patients receiving treatment to the baseline test‐retest repeatability. This analysis was performed with the median parameter values from within the ROIs. To evaluate test‐retest repeatability, intersession within‐subject standard deviation (wSD)38 was calculated for each IVIM parameter using the data from the patients with repeated baseline scans. Bland‐Altman plots were plotted for patients from both cohorts. We calculated the 95% confidence intervals (CIs) from the patients with repeated scans at baseline (assuming zero offsets). In the treated cohort, we used a paired t‐test to test whether parameters had significantly changed due to treatment within the cohort (significance level α = 0.05). Furthermore, patients from the treatment cohort were added to the Bland‐Altman plots and individual patients who had changes exceeding the 95% CIs were considered to have significant changes in tumor microstructure.39

3. RESULTS

3.1. Simulations: characterization and optimization

The original network, IVIM‐NETorig, showed substantially lower NRMSE for all estimated parameters than the LS and Bayesian approaches. However, IVIM‐NETorig had strong correlations between D* and f (high ρ(D*, f); Table 2 and Figure 2D), and had considerable CVNET.

TABLE 2.

NRMSE, ρ, and CVNET of the LS approach, Bayesian approach, IVIM‐NETorig, and IVIM‐NEToptim for the estimated parameters IVIM (D, f, D*) in simulations at SNR 20 for 50 repeated trainings a , *

Least squares Bayesian IVIM‐NETorig IVIM‐NEToptim
NRMSE D [fraction] 0.279 0.233 0.196 (0.190‐0.214) 0.177 (0.176‐0.178)
NRMSE f [fraction] 0.387 0.281 0.267 (0.259‐0.273) 0.220 (0.218‐0.222)
NRMSE D* [fraction] 0.805 0.575 0.393 (0.382‐0.414) 0.386 (0.381‐0.390)
ρ(D, D*) 0.24 0.08 0.23 (0.17‐0.28) 0.20 (0.19‐0.21)
ρ(D, f) 0.18 0.03 0.04 (0.02‐0.09) 0.01 (0.00‐0.01)
ρ(D*, f) 0.20 0.13 0.74 (0.64‐0.80) 0.22 (0.23‐0.2)
CVNET D [fraction] 0 0 0.104 0.013
CVNET f [fraction] 0 0 0.054 0.020
CVNET D* [fraction] 0 0 0.110 0.036
a

Values of IVIM‐NET: median (interquartile range).

FIGURE 2.

FIGURE 2

D* plotted against f for simulations (A), LS (B), Bayesian (C), IVIM‐NETorig (D), and IVIM‐NEToptim (E). In all plots, the values of the simulations are presented in gray. The apparent patterns in the LS approach (many predictions at D* = 0.2 mm2/s) and IVIM‐NETorig (the line flips at D* = 0 mm2/s) are a result of the fit constraints

The NRMSE, ρ, and CVNET for all hyperparameter combinations are shown in the Supporting Information Figures S2‐S9. The summarizing sum of ranks (Supporting Information Figures S5 and S9) allowed us to determine IVIM‐NEToptim (Table 1). IVIM‐NEToptim resolved the high ρ(D*, f) found in IVIM‐NETorig (Table 2; Figure 2D,E) and substantially reduced the NRMSE and CVNET. Single changes away from IVIM‐NEToptim can lead to marginally better NRMSE, lower ρ or lower CVNET (Figure 3), but only at a cost to the other two attributes. It is clear that the reduced ρ(D*, f) cannot be attributed to a single parameter, but was a result of the combination of sigmoid constraints and batch normalization (Supporting Information Figure S3). Adding dropout (10%), fitting S 0 and using our parallel network design decreased the NRMSE, while still having a low ρ(D*, f) (Table 2). Increasing dropout in IVIM‐NEToptim or using a single network architecture resulted in similar NRMSE, however, increased ρ(D*, f) (Figure 3; Supporting Information Figures S2‐S4). Generally, increasing the number of hidden layers resulted in a marginally higher ρ, and lower NRMSE and CVNET. A too high/low LR (Supporting Information Figures S5‐S7) caused higher NRMSEs and less consistency.

FIGURE 3.

FIGURE 3

A, NRMSE (left), ρ (center), and CVNET (right) plots of the estimated IVIM parameters (D, f, and D*) with a single parameter change for IVIM‐NEToptim (green) at SNR 20 for 50 repeated trainings. B, The ranked plot of IVIM‐NEToptim

IVIM‐NEToptim was superior to the LS and Bayesian approaches for SNRs 8‐33. Compared to IVIM‐NETorig, IVIM‐NEToptim was associated with improved NRMSE for f and D at all SNRs (Figure 4). For D*, the networks performed similarly regarding NRMSE, with IVIM‐NEToptim performing slightly better at SNRs > 20 and IVIM‐NETorig for SNRs < 20. IVIM‐NEToptim had lower ρ(D*, f) than IVIM‐NETorig and improved CVNET for all SNR levels.

FIGURE 4.

FIGURE 4

NRMSE (left), ρ (center), and CVNET (right) plots of the estimated IVIM parameters (D, f, and D*) vs SNR for the LS approach (blue), Bayesian approach (brown), IVIM‐NETorig (orange), and IVIM‐NEToptim (green) approaches to IVIM fitting. The 5 to 95 percentiles of IVIM‐NET for 50 repeated trainings are plotted as error bars and show that IVIM‐NETorig is highly inconsistent in producing IVIM parameters for multiple repeated trainings at all SNRs. IVIM‐NEToptim outperforms IVIM‐NETorig for all SNRs. As the LS and Bayesian approaches are deterministic, their CVNET was zero and not plotted. The LS and Bayesian approaches are superior at high SNRs

3.2. Verification in patients with PDAC

Examples of parameter maps computed with the LS approach, Bayesian approach, and IVIM‐NEToptim together with two individual voxel fits of PDAC patients from both cohorts are presented in Figures 5 and 6. Additional parameter maps of 10 other PDAC patients are shown in the Supporting Information Figures S11‐S20. Qualitatively comparing the parameter maps shows that IVIM‐NEToptim has very similar voxel values as the LS and Bayesian approaches for most voxels. However, where the LS and Bayesian approaches sometimes show “noisy” voxels (ie, different from their neighbors) with substantially higher f (order of 1) and lower D (some voxels as low as D = 0 mm2/s; Supporting Information Figures S11, S12) and D* (oftentimes to the lower bound of D*; Supporting Information Figures S12, S14‐S16, S19), IVIM‐NEToptim often sticks to sensible D, f, and D* that are similar to the neighboring voxels resulting in more homogenous parameter maps. Note that IVIM‐NET is fitted at a per‐voxel level and is unaware of the voxel location. Quantitatively evaluating the parameter maps shows that IVIM‐NEToptim had significantly better PNR than both the LS and Bayesian approaches for D and D* (Table 3) and significantly better PNR than the LS approach for f.

FIGURE 5.

FIGURE 5

IVIM parameter maps (D, f, D*) of the LS approach, Bayesian approach, and IVIM‐NEToptim of a PDAC patient of the test‐retest cohort. The red ROI represents the PDAC, the two highlighted blue regions correlate to the voxels from the log‐plots below. The yellow square zooms in on the two highlighted voxels in the tumor. In the plots, the small light gray dots are the repeated measures, and the big black dots are the root‐mean‐squares of these repeated measures. The plot parameters are shown below. The light blue voxel (left plot) shows consistency in IVIM parameters for all three fitting approaches. Although the data are similar in the neighboring dark blue voxel (right plot) with a lower IVIM effect, the LS and Bayesian approaches compute a higher f, lower D, and very low D* compared to their parameters in the light blue voxel. IVIM‐NEToptim shows more consistency in IVIM parameters between the two neighboring voxels with a lower f for the dark blue voxel. In the parametric maps computed by IVIM‐NEToptim, the tissues appear more homogeneous, whereas the LS approach shows noisier parameter maps, particularly around the tumor region

FIGURE 6.

FIGURE 6

IVIM parameter maps (D, f, D*) of the LS approach, Bayesian approach, and IVIM‐NEToptim of a PDAC patient of the treated cohort before CRT. The red ROI represents the PDAC and the green ROI represents the 2D homogenous liver tissue ROI. The two highlighted blue regions correlate to the voxels from the log‐plots below. The yellow square zooms in on the two highlighted voxels in the tumor. In the plots, the small light gray dots are the repeated measures, and the big black dots are the root‐mean‐squares of these repeated measures. Both plots show a low IVIM effect. The plot parameters are shown below. The light blue voxel (left plot) shows consistency in IVIM parameters between the LS approach and IVIM‐NEToptim with low f, and moderate D and D*, while the Bayesian approach shows higher f, lower D, and very low D*. Although the data are similar in the neighboring dark blue voxel (right plot), the LS and Bayesian approaches compute a higher f, lower D, and very low D* compared to their parameters in the light blue voxel. IVIM‐NEToptim shows more consistency in IVIM parameters between the two neighboring voxels with a consistent low f. In the parametric maps computed by IVIM‐NEToptim, the tissues appear more homogeneous, particularly in the liver, the kidneys and around the tumor ROI

TABLE 3.

PNR of homogenous liver tissue (top panel), wSD (middle panel), and mean IVIM parameters for the patients with treatment (bottom panel)

PNR D f D*
LS 5.6 3.1 1.8
Bayesian 6.3 4.0 2.3
IVIM‐NEToptim 8.1 a , * 3.9 4.0 a , *
wSD D [× 10−3 mm2/s] f [%] D* [× 10−3 mm2/s]
LS 0.10 6.2 24.9
Bayesian 0.09 4.9 5.1
IVIM‐NEToptim 0.06 2.4 15.8
Mean treatment D [× 10−3 mm2/s] f [%] D* [× 10−3 mm2/s]
Pre Post Pre Post Pre Post
LS 1.35 ** 1.51 ** 13.1 16.3 52 48
Bayesian 1.18 1.30 20.4 23.4 8.6 17.7
IVIM‐NEToptim 1.57 ** 1.68 ** 5.3 ** 9.1 ** 92 88
*

Significantly (P < .05) better PNR compared to both of the other fitting approaches, determined by a two paired t‐test, are printed bold.

**

Significant (P < .05) changes between pre and post‐treatment, determined by a paired t‐test, are printed bold.

In the test‐retest cohort, IVIM‐NEToptim showed the lowest wSD for D and f (Table 3), while the Bayesian approach had the lowest wSD for D*. When averaging IVIM parameters for the repeated patient scans, IVIM‐NEToptim computed a higher D, lower f, and higher D* than the LS and Bayesian approaches in the tumor (Table 3). The repeated scans are visualized as black x’s in the Bland‐Altman plots, together with their 95% CIs in Figure 7.

FIGURE 7.

FIGURE 7

Bland‐Altman plots of the LS, Bayesian, and IVIM‐NEToptim approaches to IVIM fitting showing the mean and difference (∆) between the intersession repeatability patients (black crosses) and the mean and ∆ between pre‐ and post‐treatment patients (colored symbols), which represents the treatment effects. The dotted lines indicate the 95% CI of the test‐retest data. Colored measurements that exceed the 95% CI were considered significant to treatment response

When considering the CRT patients as a whole, IVIM‐NEToptim found a significant increase in mean D and f after treatment, whereas the LS approach found only a significant increase in D after treatment in the tumor (Table 3). The Bayesian approach found no significant change in IVIM parameters.

Figure 7 shows the individual change in IVIM parameter values of patients receiving CRT compared to the 95% CIs of the test‐retest cohort. With 10 significant changes, IVIM‐NEToptim detected the most patients with significant parameter changes after CRT, with 4 individual patients with increased D, 3 patients with increased f, and 3 patients with changes in D*. In comparison, the LS and Bayesian approaches detected only two and three significant parameter changes, respectively.

The average interference fitting time of IVIM‐NEToptim after training was 3.0 × 10−5 s/vox, whereas the average fitting times of the LS and Bayesian approaches were 4.2 × 10−3 s and 1.0 × 10−1 s/vox, respectively. The median training time for IVIM‐NEToptim (20 repeats) was 572 s with a range of 401 to 685 s, which for our dataset resulted in 2.9 × 10−4 s/vox training.

4. DISCUSSION

This study is the first to show the potential clinical benefit of DNNs for IVIM fitting to DWI data in a patient cohort. We successfully developed and trained IVIM‐NEToptim, an unsupervised PI‐DNN IVIM fitting approach to DWI data that predicts accurate, independent, and consistent IVIM parameters in simulations and in vivo in patients with PDAC. IVIM‐NEToptim consisted of a parallel network architecture with two hidden layers, batch normalization, dropout of 10%, sigmoid constraints, and fitted S 0. Optimized training was performed using an Adam optimizer with an LR of 3 × 10−5. In simulations, IVIM‐NEToptim outperformed the original version, IVIM‐NETorig, by offering more accurate estimates of D, f and D*, with substantially less correlation between the estimated parameters D* and f, and more consistent parameter prediction. Furthermore, simulations demonstrated that IVIM‐NEToptim had substantially better accuracy than the conventional LS and state‐of‐the‐art Bayesian approaches. Finally, in patients with PDAC, IVIM‐NEToptim also outperformed the alternatives. IVIM‐NEToptim showed the most detailed and significantly less noisy parameter maps, and a significant change in D and f for the whole cohort receiving CRT. Furthermore, IVIM‐NEToptim was associated with the best test‐retest repeatability (smallest wSD) for D and f, which allowed it to detect the most patients with significant changes in all IVIM parameters after CRT.

IVIM‐NEToptim detected a significant positive trend in D and f for the whole cohort of patients receiving CRT, whereas the LS approach only found a significant positive trend in D. Also, IVIM‐NEToptim detected four patients with a significant parameter increase for D, whereas the LS approach detected only one patient. These findings strongly suggest IVIM‐NEToptim as a good alternative for IVIM fitting in PDAC patients. Findings from other studies support this increase in D 40 and f 41 during CRT in PDAC patients. In general, PDACs tend to have lower diffusion due to the impeded water movement of compressing cells.42 Furthermore, PDACs are typically hypoperfused due to solid stress generated by the dense stroma and significant tumor sclerosis creating elevated interstitial pressure, which compresses tumor feeding vessels.41, 43, 44 An increase in diffusion is likely a consequence of a reduction in cell density due to necrosis as a result of treatment.45, 46 An increase in perfusion can be explained two‐fold: an effective treatment could reduce the amount of stroma and associated solid stress47, 48; furthermore, cell necrosis inside the tumor can reduce interstitial pressure.47 Not all patients demonstrated a significant change induced by treatment. Therefore, using IVIM to discriminate between individual treatment effects may be feasible in the future. As treatment of these patients was part of induction therapy and patients received surgery directly after, overall survival cannot be attributed purely to CRT effects. Hence, given the limited number of patients and the diluted treatment effect, we did not compare overall survival between patients that showed potential treatment effects and others.

Our previous work35 showed that the LS approach for IVIM fitting was sensitive to individual treatment effects. However, the high wSD limited the study to detect individual treatment effects. Furthermore, that work35 used denoised DWI b‐images that substantially degraded image sharpness and tumor boundaries were harder to detect (eg, compare figures from this work to example figures from earlier work9). Conversely, our present study demonstrates that DNNs can estimate parameter maps directly from the noisy data resulting in sharp high‐quality IVIM parameter maps.

For most voxels, IVIM‐NEToptim produces very similar estimates to the LS and Bayesian approaches. However, within the tumor ROI, IVIM‐NEToptim shows consistently different mean baseline parameters than the LS and Bayesian approaches (Table 3). We believe that there are two major contributors to this discrepancy in mean values. (1) The LS and Bayesian approaches have more noisy parameter maps with some individual voxels showing extreme estimates. (2) IVIM‐NEToptim is seemingly better at estimating parameters in regions of poor perfusion. The first observation is demonstrated by the individual voxel fits (Figures 5 and 6; Supporting Information Figures S11‐S20), where the LS and Bayesian approaches occasionally compute noisy IVIM parameters with a substantially higher f, and lower D and D* than IVIM‐NEToptim. As the LS approach minimizes the sum of the residuals, this parameter combination could describe better the noisy data. However, inspecting neighboring voxels with, respectively, similar noisy data shows that the LS and Bayesian approaches are inconsistent in producing the same IVIM parameters, whereas IVIM‐NEToptim is more consistent. The second note is especially interesting for PDACs, which are generally hypoperfused.41, 43 Other studies reported an overestimation of perfusion parameters in poorly perfused tissue,49, 50, 51 and indeed, the LS and Bayesian approaches show high and noisy perfusion fractions maps in the PDACs. Conversely, IVIM‐NEToptim shows consistently low and less noisy perfusion in these regions. Another interesting observation is that in Figure 6, IVIM‐NEToptim shows a very similar f map to the LS approach for almost all tissue, suggesting again that there is no bias. Yet, contrary to the LS approach, IVIM‐NEToptim has a homogeneously low perfusion map in the PDAC (ie, Figures 5 and 6; Supporting information Figures S11‐S20). In the absence of ground truth in patients, we must rely on visual assessment of parameter map quality, the ability to detect treatment response, and the simulation results, in order to infer the best performing estimator. Given the evidence provided in this study, we argue that combined these factors rule in favor of IVIM‐NEToptim.

Although IVIM‐NET showed consistently better results both in simulations and in vivo, IVIM‐NET predicts different IVIM parameters in repeated training. This causes a new sort of variability that, until now, was not an issue in fitting parameter maps. There may be methods to mitigate this variability. First, when probing treatment response, we would advise using one network such that this additional effect is not different pre‐ and post‐treatment. Second, to reduce the variation, one could consider taking the median prediction from 10 repeated trainings instead. We did so in an exploratory study where we formed 5 groups of 10 networks and showed that the median of 10 networks was substantially more consistent, with CVNET values of 3.2 × 10−3, 4.9 × 10−3, and 9.3 × 10−3 for D, f, and D*, respectively. Having a set of networks will also allow the user to estimate the variation on the predicted parameter. Finally, although we see this additional uncertainty, we would like to stress that it is secondary to the overall error of the LS approach, which is apparent from the fact that in the simulations, all 50 instances of IVIM‐NEToptim had lower NRMSE than the LS approach.

IVIM‐NEToptim outperformed IVIM‐NETorig at SNRs 8‐100 and was superior to the LS and Bayesian approaches for SNRs 8‐33 (Figure 4). However, at extremely high SNR (SNR = 100; Figure 4), the LS approach outperformed IVIM‐NET. The Levenberg‐Marquardt algorithm for the LS function is an iterative function that finds a minimum of the squared difference. For a relatively smooth loss landscape and high SNR signal, the LS algorithm is designed to find the correct parameter estimates. However, at low SNR, the LS approach has trouble finding the correct parameters. This occurs either because the loss landscape is no longer smooth and, hence, it gets stuck in a local minimum, or, what we believe is more common, the noise has changed the signal such that the global optimum no longer is nearby the ground truth parameters. Moreover, a DNN consists of a complex system that needs to encompass estimating the IVIM parameters for all voxels. It turns out that having been trained on all voxels enables better estimates for individual voxels at low SNR. We expect that DNNs focus on more consistent minima with parameter values that are more frequently observed. This might be similar to data‐driven Bayesian fitting approaches.15, 52 Conversely, IVIM‐NET seems to reach a maximum accuracy at high SNR. Potentially more complex DNNs that are optimized with simulations done at high SNR could handle the subtle signal changes of the IVIM parameters at these SNRs. However, typical SNR values for IVIM data are <50. Therefore, our findings suggest that using IVIM‐NET instead of the LS and Bayesian approaches for IVIM fitting would be beneficial in a clinical setting.

The choice of the hyperparameters for IVIM‐NEToptim was based on an optimal combination of accuracy, independence, and consistency across all IVIM parameters. However, other hyperparameter options may be more appropriate when characterizing an individual IVIM parameter (eg, when an observer is only interested in D and IVIM is only used to correct for perfusion). Supporting Information Figures S2‐S9 can help interested readers select the best network for their purposes.

The high dependency between D* and f that appears in IVIM‐NETorig could not be attributed to a single cause. Initially, we expected that this dependency originated in the fully connected shared hidden layers of the original network. However, ρ remains substantial when adding the “parallel network architecture” to IVIM‐NETorig (Supporting Information Figure S10). Using IVIM‐NEToptim and a single network architecture showed slightly worse performance in simulations regarding ρ(D*, f), but still had sufficient accuracy and consistency. The dependencies between the estimated IVIM parameters are not per se specific to unsupervised DNNs. For instance, similar dependencies between D* and D or f were found in a different data‐driven Bayesian fitting approach.9 For IVIM‐NEToptim, these dependencies were small at clinical SNR values and similar to those of the LS approach.

Although simulation studies in parameter estimation are extremely valuable as the underlying parameter values are known, they also come with limitations. One limitation is that the noise characterization of real data can be diverse and hard to model. For instance, DWI artifacts caused by motion are not considered in simulations and may affect the results of fitting the IVIM model.53 Another limitation is the underlying assumption that data are perfectly bi‐exponential. In reality, the IVIM model is a simplification and real data will be more complex.

5. CONCLUSIONS

We substantially improved the accuracy, independence, and consistency of both diffusion and perfusion parameters from IVIM‐NET by changing the network architecture and tuning hyperparameters. Our new IVIM‐NEToptim is considerably faster, and computes less noisy and more detailed parameter maps with substantially better test‐retest repeatability for D and f than alternative state‐of‐the‐art fitting methods. Furthermore, IVIM‐NEToptim was able to detect the most individual patients with significant changes in the IVIM parameters throughout CRT. These results strongly suggest using IVIM‐NEToptim for detection of treatment response in individual patients.

Supporting information

FIGURE S1 Plots of the estimated IVIM parameters (D, f, D*) where no Spearman rank correlation coefficient (ρ) can be determined and is set to a ρ of 1. In all plots, the values of the simulations are presented in grey

FIGURE S2 Normalized root‐mean‐square error (NRMSE) boxplots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S3 Spearman rank correlation coefficient (ρ) boxplots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S4 Normalized Coefficient of variation (CVNET) plots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S5 Ranked plots of the metrics (NRMSE, ρ and CVNET) of evaluation 1 that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S6 Normalized root‐mean‐square error (NRMSE) boxplots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S7 Spearman rank correlation coefficient (ρ) boxplots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S8 Normalized coefficient of variation (CVNET) plots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S9 Ranked plots of the metrics (NRMSE, ρ and CVNET) of evaluation 2 for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S10 Normalised root‐mean‐square error (NRMSE; left), Spearman rank correlation coefficient (ρ; center) and normalized coefficient of variation (CVNET; right) plots of the estimated IVIM parameters (D, f and D*) with a single parameter change for IVIM‐NETorig (orange) at SNR 20 for 50 repeated trainings. The ρ(D*, f) remains substantial for single deviations from IVIM‐NETorig

FIGURE S11 See Table S1

FIGURE S12 See Table S1

FIGURE S13 See Table S1

FIGURE S14 See Table S1

FIGURE S15 See Table S1

FIGURE S16 See Table S1

FIGURE S17 See Table S1

FIGURE S18 See Table S1

FIGURE S19 See Table S1

FIGURE S20 See Table S1

TABLE S1 Overview of the parameter maps of Supporting Information Figures S11‐S20

ACKNOWLEDGMENTS

The KWF Dutch Cancer Society supported this work under Grants No. KWF‐UVA 18410 and KWF‐UVA 2013.5932. M.P.T. Kaandorp and P.T. While gratefully acknowledge support from the Research Council of Norway under FRIPRO Researcher Project 302624.

Kaandorp MPT, Barbieri S, Klaassen R, et al. Improved unsupervised physics‐informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients. Magn Reson Med. 2021;86:2250–2265. 10.1002/mrm.28852

DATA AVAILABILITY STATEMENT

To stimulate a wider clinical implementation of IVIM, we have made the code of IVIM‐NET available on GitHub: https://github.com/oliverchampion/IVIMNET. This includes some simple introductory examples in simulations and additional volunteer data. We encourage our peers to use it in their research.

REFERENCES

  • 1.Le Bihan D, Breton E, Lallemand D, Aubin ML, Vignaud J, Laval‐Jeantet M. Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology. 1988;168:497‐505. [DOI] [PubMed] [Google Scholar]
  • 2.Cho GY, Gennaro L, Sutton EJ, et al. Intravoxel incoherent motion (IVIM) histogram biomarkers for prediction of neoadjuvant treatment response in breast cancer patients. Eur J Radiol Open. 2017;4:101‐107. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Zhu LI, Wang H, Zhu L, et al. Predictive and prognostic value of intravoxel incoherent motion (IVIM) MR imaging in patients with advanced cervical cancers undergoing concurrent chemo‐radiotherapy. Sci Rep. 2017;7:1‐9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Ma W, Zhang G, Ren J, et al. Quantitative parameters of intravoxel incoherent motion diffusion weighted imaging (IVIM‐DWI): potential application in predicting pathological grades of pancreatic ductal adenocarcinoma. Quant Imaging Med Surg. 2018;8:301‐310. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Klaassen R, Steins A, Gurney‐Champion OJ, et al. Pathological validation and prognostic potential of quantitative MRI in the characterization of pancreas cancer: preliminary experience. Mol Oncol. 2020;14:2176‐2189. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Paschoal AM, Leoni RF, dos Santos AC, Paiva FF. Intravoxel incoherent motion MRI in neurological and cerebrovascular diseases. NeuroImage Clin. 2018;20:705‐714. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Zhang Y‐D, Wang Q, Wu C‐J, et al. The histogram analysis of diffusion‐weighted intravoxel incoherent motion (IVIM) imaging for differentiating the gleason grade of prostate cancer. Eur Radiol. 2015;25:994‐1004. [DOI] [PubMed] [Google Scholar]
  • 8.Li YT, Cercueil JP, Yuan J, Chen W, Loffroy R, Wáng YXJ. Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. Quant Imaging Med Surg. 2017;7:59‐78. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Gurney‐Champion OJ, Klaassen R, Froeling M, et al. Comparison of six fit algorithms for the intravoxel incoherent motion model of diffusion‐weighted magnetic resonance imaging data of pancreatic cancer patients. PLoS One. 2018;13:1‐18. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Andreou A, Koh DM, Collins DJ, et al. Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion‐weighted MR imaging in normal liver and metastases. Eur Radiol. 2013;23:428‐434. [DOI] [PubMed] [Google Scholar]
  • 11.Barbieri S, Gurney‐Champion OJ, Klaassen R, Thoeny HC. Deep learning how to fit an intravoxel incoherent motion model to diffusion‐weighted MRI. Magn Reson Med. 2020;83:312‐321. [DOI] [PubMed] [Google Scholar]
  • 12.Keenan KE, Biller JR, Delfino JG, et al. Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs. J Magn Reson Imaging. 2019;49:e26‐e39. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Neil JJ, Bretthorst GL. On the use of bayesian probability theory for analysis of exponential decay date: an example taken from intravoxel incoherent motion experiments. Magn Reson Med. 1993;29:642‐647. [DOI] [PubMed] [Google Scholar]
  • 14.Barbieri S, Donati OF, Froehlich JM, Thoeny HC. Impact of the calculation algorithm on biexponential fitting of diffusion‐weighted MRI in upper abdominal organs. Magn Reson Med. 2016;75:2175‐2184. [DOI] [PubMed] [Google Scholar]
  • 15.Orton MR, Collins DJ, Koh DM, Leach MO. Improved intravoxel incoherent motion analysis of diffusion weighted imaging by data driven Bayesian modeling. Magn Reson Med. 2014;71:411‐420. [DOI] [PubMed] [Google Scholar]
  • 16.While PT. A comparative simulation study of Bayesian fitting approaches to intravoxel incoherent motion modeling in diffusion‐weighted MRI. Magn Reson Med. 2017;78:2373‐2387. [DOI] [PubMed] [Google Scholar]
  • 17.Bertleff M, Domsch S, Weingärtner S, et al. Diffusion parameter mapping with the combined intravoxel incoherent motion and kurtosis model using artificial neural networks at 3 T. NMR Biomed. 2017;30:1‐11. [DOI] [PubMed] [Google Scholar]
  • 18.Hammernik K, Klatzer T, Kobler E, et al. Learning a variational network for reconstruction of accelerated MRI data. Magn Reson Med. 2018;79:3055‐3071. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Aggarwal HK, Mani MP, Jacob M. Modl‐mussels: model‐based deep learning for multishot sensitivity‐encoded diffusion MRI. IEEE Trans Med Imaging. 2020;39:1268‐1277. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Paszke A, Gross S, Chintala S, et al. Automatic differentiation in PyTorch. NIPS‐W. 2017;22:2‐8. [Google Scholar]
  • 21.Clevert DA, Unterthiner T, Hochreiter S. Fast and accurate deep network learning by exponential linear units (ELUs). 4th Int. Conf. Learn. Represent. ICLR 2016 ‐ Conf. Track Proc. 2016, pp. 1‐14.
  • 22.Srivastava N, Hinton G, Krizhevsky A, Sutskever I, Salakhutdinov R. Dropout: a simple way to prevent neural networks from overfitting. J Mach Learn Res. 2014;15:1929‐1958. [Google Scholar]
  • 23.Ioffe S, Szegedy C. Batch normalization: accelerating deep network training by reducing internal covariate shift. 32nd Int Conf Mach Learn ICML 2015. 2015;1:448‐456. [Google Scholar]
  • 24.Kingma DP, Ba JL. Adam: a method for stochastic optimization. 3rd Int. Conf. Learn. Represent. ICLR 2015 ‐ Conf. Track Proc. 2015, pp. 1‐15.
  • 25.van Herten RLM, Chiribiri A, Breeuwer M, Veta M, Scannell CM. Physics‐informed neural networks for myocardial perfusion MRI quantification. arXiv. 2020;2011.12844. [DOI] [PMC free article] [PubMed]
  • 26.Barbieri S, Donati OF, Froehlich JM, Thoeny HC. Comparison of intravoxel incoherent motion parameters across MR imagers and field strengths: evaluation in upper abdominal organs. Radiology. 2016;279:784‐794. [DOI] [PubMed] [Google Scholar]
  • 27.Koay CG, Basser PJ. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson. 2006;179:317‐322. [DOI] [PubMed] [Google Scholar]
  • 28.Levenberg K. A method for the solution of certain non‐linear problems in Least squares. Q Appl Math. 1944;2:164‐168. [Google Scholar]
  • 29.Marquardt DW. An algorithm for least‐squares estimation of nonlinear parameters. J Soc Ind Appl Math. 1963;11:431‐441. [Google Scholar]
  • 30.Cho GY, Moy L, Zhang JL, et al. Comparison of fitting methods and b‐value sampling strategies for intravoxel incoherent motion in breast cancer. Magn Reson Med. 2015;74:1077‐1085. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Lemke A, Stieltjes B, Schad LR, Laun FB. Toward an optimal distribution of b values for intravoxel incoherent motion imaging. Magn Reson Imaging. 2011;29:766‐776. [DOI] [PubMed] [Google Scholar]
  • 32.Cohen AD, Schieke MC, Hohenwalter MD, Schmainda KM. The effect of low b‐values on the intravoxel incoherent motion derived pseudodiffusion parameter in liver. Magn Reson Med. 2015;73:306‐311. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Jalnefjord O, Andersson M, Montelius M, et al. Comparison of methods for estimation of the intravoxel incoherent motion (IVIM) diffusion coefficient (D) and perfusion fraction (f). Magn Reson Mater Phys Biol Med. 2018;31:715‐723. [DOI] [PubMed] [Google Scholar]
  • 34.Klaassen R, Gurney‐Champion OJ, Wilmink JW, et al. Repeatability and correlations of dynamic contrast enhanced and T2* MRI in patients with advanced pancreatic ductal adenocarcinoma. Magn Reson Imaging. 2018;50:1‐9. [DOI] [PubMed] [Google Scholar]
  • 35.Klaassen R, Gurney‐Champion OJ, Engelbrecht MRW, et al. Evaluation of six diffusion‐weighted MRI models for assessing effects of neoadjuvant chemoradiation in pancreatic cancer patients. Int J Radiat Oncol Biol Phys. 2018;102:1052‐1062. [DOI] [PubMed] [Google Scholar]
  • 36.Versteijne E, Suker M, Groothuis K, et al. Original reports abstract preoperative chemoradiotherapy versus immediate surgery for resectable and borderline resectable pancreatic cancer: results of the dutch randomized phase III PREOPANC Trial. J Clin Oncol. 2020;38:1763‐1774. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Klein S, Staring M, Murphy K, Viergever MA, Pluim J. A toolbox for intensity‐based medical image registration. IEEE Trans Med Imaging. 2010;29:196‐205. [DOI] [PubMed] [Google Scholar]
  • 38.Barnhart HX, Barboriak DP. Applications of the repeatability of quantitative imaging biomarkers: a review of statistical analysis of repeat data sets. Transl Oncol. 2009;2:231‐235. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Bland JM, Altman DG. Statistics notes: measurement error. BMJ. 1996;313:744. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Trajkovic‐Arsic M, Heid I, Steiger K, et al. Apparent diffusion coefficient (ADC) predicts therapy response in pancreatic ductal adenocarcinoma. Sci Rep. 2017;7:1‐9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Kim H, Morgan DE, Schexnailder P, et al. Accurate therapeutic response assessment of pancreatic ductal adenocarcinoma using quantitative dynamic contrast‐enhanced magnetic resonance imaging with a point‐of‐care perfusion phantom: a pilot study. Invest Radiol. 2019;54:16‐22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Robertis RDe, Martini PT, Demozzi E, et al. Diffusion‐weighted imaging of pancreatic cancer. World J Radiol. 2015;7:319. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Sofuni A, Iijima H, Moriyasu F, et al. Differential diagnosis of pancreatic tumors using ultrasound contrast imaging. J Gastroenterol. 2005;40:518‐525. [DOI] [PubMed] [Google Scholar]
  • 44.Stopa KB, Kusiak AA, Szopa MD, Ferdek PE, Jakubowska MA. Pancreatic cancer and its microenvironment—recent advances and current controversies. Int J Mol Sci. 2020;21:3218. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Zhu LI, Zhu L, Shi H, et al. Evaluating early response of cervical cancer under concurrent chemo‐radiotherapy by intravoxel incoherent motion MR imaging. BMC Cancer. 2016;16:1‐8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Chiaradia M, Baranes L, Van Nhieu JT, et al. Intravoxel incoherent motion (IVIM) MR imaging of colorectal liver metastases: are we only looking at tumor necrosis? J Magn Reson Imaging. 2014;39:317‐325. [DOI] [PubMed] [Google Scholar]
  • 47.Kim H, Samuel S, Lopez‐Casas P, et al. SPARC‐independent delivery of nab‐paclitaxel without depleting tumor stroma in patient‐derived pancreatic cancer xenografts. Mol Cancer Ther. 2016;15:680‐688. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Hamdy A, Ichikawa Y, Toyomasu Y, et al. Perfusion CT to assess response to neoadjuvant chemotherapy and radiation therapy in pancreatic ductal adenocarcinoma: initial experience. Radiology. 2019;292:628‐635. [DOI] [PubMed] [Google Scholar]
  • 49.Barbieri S, Donati OF, Froehlich JM, Thoeny HC. Impact of the calculation algorithm on biexponential fitting of diffusion‐weighted MRI in upper abdominal organs. Magn Reson Med. 2016;75:2175‐2184. [DOI] [PubMed] [Google Scholar]
  • 50.Meeus EM, Novak J, Withey SB, Zarinabad N, Dehghani H, Peet AC. Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue. J Magn Reson Imaging. 2017;45:1325‐1334. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Gurney‐Champion OJ, Froeling M, Klaassen R, et al. Minimizing the acquisition time for intravoxel incoherent motion magnetic resonance imaging acquisitions in the liver and pancreas. Invest Radiol. 2016;51:211‐220. [DOI] [PubMed] [Google Scholar]
  • 52.Friedman N, Goldszmidt M, Wyner A. Data analysis with Bayesian networks: a bootstrap approach. Uncertainty Artif Intell. 1999:206‐215. [Google Scholar]
  • 53.Veraart J, Rajan J, Peeters RR, Leemans A, Sunaert S, Sijbers J. Comprehensive framework for accurate diffusion MRI parameter estimation. Magn Reson Med. 2013;70:972‐984. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

FIGURE S1 Plots of the estimated IVIM parameters (D, f, D*) where no Spearman rank correlation coefficient (ρ) can be determined and is set to a ρ of 1. In all plots, the values of the simulations are presented in grey

FIGURE S2 Normalized root‐mean‐square error (NRMSE) boxplots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S3 Spearman rank correlation coefficient (ρ) boxplots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S4 Normalized Coefficient of variation (CVNET) plots of the estimated IVIM parameters (D, f, D*) that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S5 Ranked plots of the metrics (NRMSE, ρ and CVNET) of evaluation 1 that contain all hyperparameter combinations with a fixed learning rate set to 1 × 10−4 and a fixed number of hidden layers set to 3 at SNR 20 for 50 repeated trainings. Highlighted in green is the intermediate step of IVIM‐NEToptim. Left of each plot shows the LS approach (blue), Bayesian approach (brown) and IVIM‐NETorig (orange; LR = 1 × 10−3)

FIGURE S6 Normalized root‐mean‐square error (NRMSE) boxplots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S7 Spearman rank correlation coefficient (ρ) boxplots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S8 Normalized coefficient of variation (CVNET) plots of the estimated IVIM parameters (D, f, D*) of the second evaluation for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S9 Ranked plots of the metrics (NRMSE, ρ and CVNET) of evaluation 2 for different LR and number of hidden layers, with fixed hyperparameters of extra fitting parameter S0, sigmoid activation functions, a parallel network architecture, 10% dropout and batch normalization at SNR 20 for 50 repeated trainings. Highlighted in green is IVIM‐NEToptim. Left of each plot shows the LS approach (blue) and Bayesian approach (brown) and IVIM‐NETorig (orange)

FIGURE S10 Normalised root‐mean‐square error (NRMSE; left), Spearman rank correlation coefficient (ρ; center) and normalized coefficient of variation (CVNET; right) plots of the estimated IVIM parameters (D, f and D*) with a single parameter change for IVIM‐NETorig (orange) at SNR 20 for 50 repeated trainings. The ρ(D*, f) remains substantial for single deviations from IVIM‐NETorig

FIGURE S11 See Table S1

FIGURE S12 See Table S1

FIGURE S13 See Table S1

FIGURE S14 See Table S1

FIGURE S15 See Table S1

FIGURE S16 See Table S1

FIGURE S17 See Table S1

FIGURE S18 See Table S1

FIGURE S19 See Table S1

FIGURE S20 See Table S1

TABLE S1 Overview of the parameter maps of Supporting Information Figures S11‐S20

Data Availability Statement

To stimulate a wider clinical implementation of IVIM, we have made the code of IVIM‐NET available on GitHub: https://github.com/oliverchampion/IVIMNET. This includes some simple introductory examples in simulations and additional volunteer data. We encourage our peers to use it in their research.