Sparse precontrast T1 mapping for high‐resolution whole‐brain DCE‐MRI

Zhibo Zhu 1,, R Marc Lebel 2,3, Yannick Bliesener 1, Jay Acharya 4, Richard Frayne 3,5, Krishna S Nayak 1,4
PMCID: PMC8362109  PMID: 34036658

Abstract

Purpose

To develop and evaluate an efficient precontrast T1 mapping technique suitable for quantitative high‐resolution whole‐brain dynamic contrast‐enhanced–magnetic resonance imaging (DCE‐MRI).

Methods

Variable flip angle (VFA) T1 mapping was considered that provides 1 × 1 × 2 mm3 resolution to match a recent high‐resolution whole‐brain DCE‐MRI protocol. Seven FAs were logarithmically spaced from 1.5° to 15°. T1 and M0 maps were estimated using model‐based reconstruction. This approach was evaluated using an anatomically realistic brain tumor digital reference object (DRO) with noise‐mimicking 3T neuroimaging and fully sampled data acquired from one healthy volunteer. Methods were also applied on fourfold prospectively undersampled VFA data from 13 patients with high‐grade gliomas.

Results

T1‐mapping precision decreased with undersampling factor R, althoughwhereas bias remained small before a critical R. In the noiseless DRO, T1 bias was <25 ms in white matter (WM) and <11 ms in brain tumor (BT). T1 standard deviation (SD) was <119.5 ms in WM (coefficient of variation [COV] ~11.0%) and <253.2 ms in BT (COV ~12.7%). In the noisy DRO, T1 bias was <50 ms in WM and <30 ms in BT. For R ≤ 10, T1 SD was <107.1 ms in WM (COV ~9.9%) and <240.9 ms in BT (COV ~12.1%). In the healthy subject, T1 bias was <30 ms for R ≤ 16. At R = 4, T1 SD was 171.4 ms (COV ~13.0%). In the prospective brain tumor study, T1 values were consistent with literature values in WM and BT.

Conclusion

High‐resolution whole‐brain VFA T1 mapping is feasible with sparse sampling, supporting its use for quantitative DCE‐MRI.

Keywords: brain tumor, model‐based reconstruction, quantitative dynamic contrast‐enhanced–magnetic resonance imaging (DCE‐MRI), sparse sampling, T1 mapping

1. INTRODUCTION

Dynamic contrast‐enhanced–magnetic resonance imaging (DCE‐MRI) is a powerful imaging tool that can reveal the spatial distribution of vascular parameters, including permeability and plasma volume, through tracer‐kinetic (TK) modeling.1, 2 It involves collecting a series of T1‐weighted images during the arrival and passage of a T1‐shortening contrast agent.3, 4 Quantitative DCE‐MRI has shown value in diagnosing and monitoring of various brain diseases, including tumors,5, 6 multiple sclerosis,7, 8 and Alzheimer disease.9

Widespread clinical application is limited by low spatial resolution, insufficient spatial coverage, and long data acquisition. Recent studies have overcome these limitations using parallel imaging techniques10, 11 and compressed sensing,12 or model‐based reconstruction techniques to simultaneously achieve high spatial resolution and whole‐brain coverage. For example, Lebel et al demonstrated a method combining compressed sensing and parallel imaging,13 which was later validated in patients with brain tumors by Guo et al.14 Several more recent works have showed the benefits of model‐based reconstruction that incorporate the model used for DCE parameter quantification. For example, Dickie et al proposed joint estimation of T1 and tracer‐kinetic maps15 to improve accuracy and precision. Guo et al developed a direct estimation of tracer‐kinetic parameters16 and a joint estimation with patient‐specific arterial input function.17 Lingala et al used dictionary‐based constraints.18 Most of these previous works either employed fully sampled T1 mapping, which is not feasible in the clinic, or assumed a fixed T1 value for brain tissue, which is not realistic.

Precontrast M0 and T1 maps with matching spatial resolution and coverage are required for these methods to be practically applied in patients. This can be achieved via variable flip angle (VFA)19 or inversion recovery (IR)20 imaging. IR is considered the gold standard for T1 mapping, and substantial bias exists between VFA and IR. Despite this bias, VFA is the most widely used approach for precontrast T1 mapping in DCE‐MRI because it is faster and acquisition parameters can be precisely matched to the three‐dimensional (3D) spoiled gradient recalled echo (SPGR) sequence that is used for the main DCE‐MRI scan. However, high‐resolution whole‐brain full‐sampling VFA imaging may be impractical because of the long scan time required. This leads to an unmet need for resolution‐ and coverage‐matched rapid precontrast T1 mapping. Lebel et al showed that T1 mapping is feasible using sparsely sampled VFA acquisition integrated with DCE‐MRI.21 Maier et al showed sparse T1 mapping estimation using total variation (TV) and total generalized variation (TGV) constraints22 in healthy volunteers. Note that the appropriateness of spatial smoothness constraints in patients with brain tumors is unclear because of potential T1 heterogeneity. These works collectively show the potential value of model‐based and/or constrained reconstruction techniques to accelerate VFA T1 mapping.

In this work, we evaluate a time‐efficient direct T1 mapping approach specifically for high‐resolution whole‐brain quantitative DCE‐MRI in patients with brain tumors. We use a brain tumor digital reference object (DRO) to determine accuracy under both noiseless and 3T‐mimicking scenarios. We evaluate the approach in vivo by retrospectively undersampling fully sampled VFA data from a healthy volunteer to identify possible artifacts and image quality issues. Finally, we apply the approach to prospectively undersampled VFA scans to assess heterogeneity of T1 measurements in patients with high‐grade gliomas.

2. METHODS

2.1. Variable flip angle T1 mapping

VFA mapping involves the collection of a series of T1‐weighted SPGR images with different prescribed FAs βi. VFA imaging is sensitive to B1+ inhomogeneity,23 which requires the acquisition of a B1+ scale map (b1) to estimate actual FAs αi=b1βi. We use the SPGR steady state signal model that describes signal Di as a function of M0, T1, actual flip angle αi, and TR:

DiM0,T1,αi=M0sinαi1E101E10cosαi (1)

where E10=eTRT1. Note that the effect of T2 decay is neglected due to short and unchanging TE. Voxel‐based pre‐contrast M0 and T1 values can be efficiently estimated through a SPGR model fitting process:

M01E10E10=AD1D2DNFA (2)

where A=sinαiDicosαi, as described by Deoni et al.23, 24 Note that M0 and T1 are jointly estimated and are, therefore, correlated. In this work, we focus on T1 accuracy and precision because it is crucial for quantitative DCE‐MRI25, 26 and is measured in meaningful physical units. The Appendix A contains an analysis of the impact of a precontrast T1 mapping error on quantitative DCE‐MRI.

2.2. Sparse T1 estimation

When VFA data/images are undersampled, it is possible to perform sparse image reconstruction for each FA before T1 estimation on a voxel‐by‐voxel basis.27, 28, 29 However, this does not leverage shared information across the images. Alternatively, T1 mapping can be performed for the entire volume in a single step directly from the undersampled k‐space data. This skips the intermediate step of forming images for each FA, and instead relies on accurate forward models. The key benefit is that T1 information is extracted from the data in an optimal way, from an information‐theoretic perspective. Details of the sampling pattern are provided in the Supporting Information and illustrated in Supporting Information Figure S1.

2.3. Direct T1 estimation

Direct T1 estimation can be performed by solving the following inverse problem:

M0,T1=minM0,T112FuSDM0,T1,αdl22 (3)

Data consistency measures the distance between the forward signal model applied to the estimate and the sampled data at measured locations in (k, FA) space, where Fu is the undersampled Fourier transform operator, S is the coil sensitivity, D is the steady state SPGR forward model including the measured b1, and d is the measured k‐space data. A necessary condition for the problem to be well‐posed is that the number of measurements are larger than the number of unknowns, for example, NFAdimCR > 2N, where C is the subspace spanned by coils, N is the number of voxels, and R is the undersampling factor. This indicates that the problem will be ill‐posed if R > NFAdimC2. Ideally, dimC is equal to number of coils, Nc, if coils are linearly independent to each other. In this work, the aforementioned problem is solved using the nonlinear conjugate gradient (NCG) method initialized with M0 = 0 and T1 = 1000 ms within the field of view.

2.4. Evaluation in a digital reference object

An anatomically realistic DRO30, 31 was used to evaluate accuracy and precision of M0 and T1 maps as a function of noise level and the undersampling rate. Each healthy tissue type in the DRO was assigned T1 values based on the literature,32 for example, 1084 ms for WM, and M0 values were normalized with respect to cerebrospinal fluid (CSF). To the best of our knowledge, a brain tumor such as a glioma, has T1 values longer than healthy tissues, with the literature reporting 1392‐3601 ms.33, 34, 35 Therefore, we set T1 to be 2000 ms for BT in the DRO. The DRO has a matrix size of 256 × 256 × 12, matching a spatial resolution of 0.94 × 0.94 × 5 mm3. Simulated scan settings, for example, FA, pulse repetition time (TR), and echo time (TE), are identical to our in vivo experiment settings, including phase encoding in the axial plane. An eight‐channel coil sensitivity map was simulated based on in vivo measurement at 3T MRI scanner (HD23; GE Healthcare). Noise was simulated at a level matching typical 3T MRI at our center, and one order of magnitude lower and higher. Undersampling factors in range from 1× to 40× were considered for the noiseless case. In the noiseless case, for each undersampling factor we considered up to 10 different realizations to account for potential variability in the sampling. For experiments under noise corruption, we considered undersampling factors ranging from 1× to 40×, each factor with one sampling pattern realization and up to 50 noise realizations, which was found enough to stabilize estimation of bias and standard deviation (SD) of T1 estimates.

Our analysis focused on white matter (WM) and brain tumor (BT) regions of interest (ROIs). T1 values within these ROI’s are reported in histograms for each undersampling factor and/or noise level. We also compare reconstructed T1 values with the assigned ground truth. Mean and SD of T1 values are plotted as a function of the undersampling factor, and the coefficient of variation (COV) is computed to numerically reflect the accuracy and precision of the results and their evolution as the undersampling factor increases.

2.5. In vivo experimental methods

In vivo experiments were performed on a clinical 3T MRI scanner (MR750; GE Healthcare) with a 12‐channel head–neck–spine receiver coil. Imaging protocols were approved by the relevant institutional review board; all subjects provided written informed consent. B1+ mapping was performed using the Bloch‐Siegert approach.36 Data were acquired with a coronal slab orientation, with superior‐inferior as the readout direction. The VFAs were logarithmically spaced from 1.5° to 15°. Acquisition settings: TR = 4.9 ms, TE = 1.9 ms, field of view (FOV) = 240 × 240 × 240 mm3, slice thickness = 2 mm, and matrix size = 256 × 240 × 120. The pulse sequence was derived from the vendor product sequence and modified to acquire specific phase encodes and tip angles; the sequence used slab‐selective excitations and the RF and gradient spoiling were unchanged.

For the retrospective study (one healthy volunteer, full sampling), the acquisition time was 16 min and 48 s. For the prospective study (13 patients), the acquisition time was 576 s consisting of both T1 mapping (245 s) and sparse DCE (5 s/frame, contrast injection at ~4 min), and a fully sampled 40 × 40 phase‐encoding grid of the k‐space center was acquired for FA = 1.5° (8 s of scan time) for coil sensitivity estimation. The coil sensitivity maps were estimated from this image, by dividing the individual‐coil low‐resolution anatomic images by the coil‐combined image. There is also a brief transient approach to steady state every time there is a change in the applied FA. We discarded the first 4.5 seconds for the first FA, and the first 2 seconds for each subsequent FA. This was adequate to ensure spins were within ±7% of their steady‐state value for T1s in the range 1300 to 2500 ms.

All reconstructions were performed offline. Tissue masks (eg, WM) for fully sampled healthy volunteer data were extracted using the FMRIB's Automated Segmentation Tool (FAST) toolbox37 (https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/FAST) using fully sampled images at 10.22°, which had the best gray matter (GM)–WM contrast‐to‐noise ratio.

2.6. Evaluation in a healthy adult

Fully sampled VFA measurement was obtained from one healthy adult volunteer (M/26). Raw data were retrospectively subsampled in (k‐, FA) space with undersampling factors ranging from 1× to 40×, each with up to 10 realizations of the randomized sampling pattern. Our analysis focused on WM ROIs. Results are reported and analyzed in a similar fashion as for noisy DRO study, except that T1 maps estimated from fully sampled scans served as reference. In addition, a T1 spatial map and an absolute fractional difference spatial map were employed to show spatial patterns in T1 values.

2.7. Prospective application to patients with brain tumors

Methods were evaluated prospectively in 13 patients with high‐grade glioma brain tumor (four males and nine females, age range 42–80 years). These data were acquired between December 2016 and April 2019. The vendor‐provided 3D spoiled gradient echo sequence was modified to include sparse VFA sampling with R = 4 before sparse DCE‐MRI, as described by Lebel et al.21 The resulting T1 maps were qualitatively evaluated by a neuroradiologist for visual quality (noise, tissue inhomogeneity, tissue differential), evidence of tumor, postsurgical cavity, and artifacts. These maps were also given a qualitative score on a three‐point Likert scale. The score was defined as follows: 0 = nondiagnostic because of artifacts and/or difficulty visualizing tissue boundaries; 1 = diagnostic, may have mild artifacts, adequate visualization of tissue boundaries; 2 = diagnostic with high quality, no visible artifacts, and well‐defined tissue boundaries).

Small ROIs were manually drawn for WM, BT, and temporalis and surgical cavities; mean and SD of T1 values are reported for these ROIs. The ROIs of the tumor were hand‐drawn by a board‐certified neuroradiologist with 9 years of experience. They were selected based on the imaging morphology and signal intensity of the tumoral and peritumoral tissue. The selections were based on the assessment of the imaging features, including regional mass effect, volume loss, and findings suggestive of cellular tumor (based on a visual qualitative assessment of the T1 mapping signal compared with other intracranial structures), which are all findings that are commonly used to assess for neoplasm on conventional MRI sequences.

3. RESULTS

3.1. Validation using a digital reference object

Figure 1 shows the results of noiseless and 3T‐mimicking noisy DRO cases. Results gathering 10 undersampling realizations and results gathering 50 noise realizations are reported for noiseless and noisy cases, respectively. The SNR level of 50 is chosen for display because it is the closest to our clinical protocol. In Figure 1A,B,E,F histograms of both tissues behave as approximately impulse for R ≤ 10, and approximately Gaussian for R ≥ 16 for noiseless cases. In the noisy cases, histograms are approximately Gaussian for R ≤ 10 and are almost flat for R ≥ 16. This can be also seen numerically from Figure 1C,D,G,H. As expected, T1 SD gets monotonically larger with higher undersampling factor. In the noiseless case, when R ≤ 10 (VFA scan time ≥137.63 s), the T1 bias is <1 ms and SD is <40 ms for both tissues. In the 3D‐mimicking case, when R ≤ 10, the T1 bias is <10 ms and SD is <110 ms (WM) and <250 ms (BT), and when R > 16, the T1 mean starts changing randomly and its SD overshoots in BT.

FIGURE 1.

FIGURE 1

Brain tumor digital reference object (DRO) results. A, T1 histograms for the noiseless DRO. B, T1 histograms for the 3T‐mimicking noisy DRO. C, T1 mean values. D, T1 standard deviation (Std) values. All are plotted as a function of (A,B,E,F) undersampling factor or (C,D,G,H) variable flip angle (VFA) scan time. VFA scan time axis is in logarithmic scale. The top row represents brain tumor (BT) region of interest (ROI), and the bottom row represents the white matter (WM) ROI. The red dot represents the reference T1 value in (A,B,E,F), and the undersampling level matching the prospective undersampling are marked bold in (C,D,G,H). As expected, precision gets monotonically worse with a higher undersampling factor. In the noiseless case, when R ≤ 16 (VFA scan time ≥137.63 s), the T1 bias is <1 ms and SD is <40 ms for both tissues. In the 3D‐mimicking case, when R ≤ 10, the T1 bias is <10 ms and SD is <110 ms (WM) and <250 ms (BT)

3.2. Validation in a healthy adult volunteer

Figure 2 shows the results of T1 mapping using healthy volunteer data. As undersampling increases, the histograms become broader and have thicker tails (Figure 2A). This matches what we observe in Figure 1. Bias is small until R ≥ 16, and SD increases with higher undersampling factor, but imprecision caused by this method is not detectable until R ≥ 10. When R ≤ 10 (VFA scan time ≥100.8 s), Figure 2B, C show T1 mapping bias <11 ms, and SD is <214 ms (COV <15%).

FIGURE 2.

FIGURE 2

Healthy volunteer results. Fully sampled data sets were retrospectively undersampled with 10 realizations of the pseudorandom data sampling pattern. (A), White matter (WM) T1 histogram as a function of undersampling factor. (B), Mean T1. C, T1 standard deviation (Std) as a function of variable flip angle (VFA) scan time. VFA scan time axis is in logarithmic scale. The mean T1 from fully sampled data is shown as the blue dashed line in (B). Bias is insignificant (<30 ms) until R ≥ 16. Precision gets worse with a higher undersampling factor, but imprecision caused by this method is not detectable until R ≥ 10. When R ≤ 10 (VFA scan time ≥100.8 s), T1 mapping bias is <11 ms, and SD is <214 ms

Figure 3 shows a series of T1 spatial maps of a representative healthy volunteer for each undersampling factor, and the associated absolute fractional difference maps. When R ≤ 10, there is less error within WM and GM in which mean fractional difference was <8.46% and <14.76%, respectively, and error concentrated around tissues of less interest. For example, bias in CSF and temporalis is, respectively, >1278.5 ms and >156.9 ms. No spatial patterns related to the data sampling method were observed. As R increases, we can observe error starting to increase in the WM and GM regions.

FIGURE 3.

FIGURE 3

Illustration of T1 spatial and absolute fractional difference maps from the healthy volunteer. Direct reconstruction of the fully sampled data is taken as the reference. Qualitatively, for R ≤ 10, we see minor error in white matter (WM) or gray matter (GM). Errors appear isolated to cerebrospinal fluid (bias > 1278.5 ms, standard deviation [SD] > 557.6 ms) and muscle (bias > 156.9 ms, SD > 209.8 ms), whose T1 values are generally less of interest in brain dynamic contrast‐enhanced–magnetic resonance imaging. Importantly, no spatial patterns indicating systemic errors were observed in the error maps. For R > 10, we observed severe error corruption of T1 maps in GM and WM regions

3.3. Demonstration in patients with brain tumors

The prospective data set contained a variety of tumor locations and time points during treatment. Demographics, qualitative diagnostic scores, and T1 values of WM, BT, and temporalis and cavity‐fillings are reported in Table 1. BT T1 values are reported from the time point with the most clear and substantial evidence of tumor, determined based on the longitudinal progression verified by contrast enhancement. No distinct artifacts were observed. One case received a qualitative score of 1, and this case has strong T1 inhomogeneity in CSF. All other cases received a qualitative score of 2. Out of 13 cases, three showed no obvious tumor based on T1 and postcontrast readings, whereas all other cases showed brain tumor and/or postsurgical abnormalities. There is noticeably higher SD in temporalis T1, and cavity‐fillings have substantially longer T1 (>4000 ms) than WM and BT. Figure 4 shows three representative examples with orthogonal cross sections of each tumor. These maps show clear T1 differentiation of WM, GM, and BT abnormality regions, as well as postsurgical cavities, with high spatial resolution. Figure 5 shows zoomed versions of the same T1 maps that showcase the ability to capture T1 heterogeneity.

TABLE 1.

Patient demographics, qualitative scores, and T1 values for white matter and brain tumor regions of interest

Sex Age Diagnostic score WM T1 (M ± SD) ms BT T1 (M ± SD) ms Muscle T1 (M ± SD) ms Cavity T1 (M ± SD) ms
F 59 2 895.0 ± 166.9 1763.2 ± 241.0 1517.8 ± 260.1 2564.3 ± 603.8
F 60 2 1003.5 ± 118.7 N/A 1683.8 ± 594.5 4621.4 ± 606.3
F 56 2 1000.4 ± 82.2 2314.3 ± 284.4 1636.0 ± 559.2 4638.4 ± 563.7
M 49 1 1094.2 ± 161.9 1856.7 ± 201.2 1444.6 ± 438.6 4541.8 ± 757.6
M 62 2 1086.4 ± 65.9 1981.6 ± 177.7 1582.9 ± 295.1 N/A
F 58 2 933.1 ± 79.9 1994.0 ± 257.7 1449.5 ± 255.0 N/A
F 71 2 1193.2 ± 92.3 N/A 1530.3 ± 256.7 4845.7 ± 506.9
M 80 2 1146.2 ± 65.2 1592.0 ± 128.7 1387.3 ± 429.7 N/A
M 42 2 1126.7 ± 142.0 N/A 1627.3 ± 374.1 5066.8 ± 865.7
F 71 2 1115.5 ± 84.2 1894.1 ± 227.4 1512.9 ± 364.1 3607.1 ± 530.5
F 61 2 1000.8 ± 51.3 1680.8 ± 155.2 1692.3 ± 356.2 4229.2 ± 265.6
F 67 2 1040.0 ± 66.2 1790.7 ± 99.0 1570.5 ± 152.0 2801.6 ± 180.7
F 52 2 1048.2 ± 92.8 1726.0 ± 177.5 1576.7 ± 397.3 N/A

Volume T1 data sets were qualitatively scored by a neuroradiologist using the following Likert scale: 0 = nondiagnostic; 1 = diagnostic with mediocre quality; 2 = diagnostic with high quality. Small ROIs were manually drawn to also yield T1 measurements, reported as mean ± SD.

Abbreviations: BT, brain tumor; F, female; M, male; N/A, not applicable; ROIs, regions of interest; SD, standard deviation; WM, white matter.

FIGURE 4.

FIGURE 4

Representative M0 and T1 maps from three patients with high‐grade glioma. Maps are volumetric, and axial, coronal, and sagittal slices through the tumor section for each patient (the first, the third, and the fifth row). M0 maps with tumor region of interest drawn in red (the second, the fourth, and the sixth row). T1 maps showing good delineation of white matter (WM), gray matter (GM), cerebrospinal fluid, and tumor. WM and GM regions have the expected homogeneity. In addition to tissue differential, these maps also reveal the locations of craniotomy (green arrow) and postsurgical cavities (blue arrow) that are filled with proteinaceous fluid such as blood in high spatial resolution

FIGURE 5.

FIGURE 5

Closeup of T1 maps from the three patients in Figure 4. Maps are zoomed into the tumor region (delineated by white dashed box in Figure 4), with narrow display range. The proposed method captures T1 heterogeneity. T1 coefficient of variation are 10.84%, 9.96%, and 7.31% for the top, middle, and bottom rows, respectively. All cases show spatial variations in T1. For example, T1 is longer in tumor center (eg, light green arrow) than in the tumor rim (eg, green arrow) and the peritumoral regions (eg, dark green arrow)

4. DISCUSSION

This study evaluated the direct estimation of native M0 and T1 maps at 3T through simulation, as well as in in vivo studies of a healthy subject and patients with brain tumors. Simulations in DROs revealed T1 measurement variability of this approach to be dominated by noise at undersampling factors ≤10, whereas errors caused by undersampling dominated above. We anticipate this cutoff point to differ for other field strengths (eg, 1.5T), coil configurations, protocols (eg, resolution, FOV), anatomies (eg, breast, prostate) and imaging tasks (eg, other quantitative MRI applications). Simulation on noise corrupted T1 measurements also showed the T1 errors in BT to be more susceptible to undersampling than in WM regions. Therefore, it is important to focus performance analysis on clinically relevant regions of interest rather than global metrics.

We used a 3D Fourier transform acquisition with Cartesian spiral subsampling because it is important to maintain the same spatial distortions between the T1 mapping and the DCE sequence. These are largely impacted by the pulse sequence, prescription, and readout trajectory and bandwidth. A limitation of this study is that we did not compare different subsampling approaches. Such an analysis has been performed for sparse DCE‐MRI acquisitions.31 We used the same subsampling strategy for T1 mapping as is being used for sparse DCE‐MRI at our institution.

Results of retrospective in vivo scans were consistent with results from the 3T‐mimicking noisy DRO, which confirms the ability of the simulation to predict in vivo performance. Specifically, both T1 mean and SD values increased with higher undersampling, as shown in Figures 1C,D and 2B,C. Up to the critical undersampling factor of 10, the trend can be explained by noise amplification related to parallel imaging because the increase was only observed in the noisy cases. However, for undersampling factors above 10, the formulated problem becomes ill‐posed, causing variations in the mean and increased SD in both noisy and noiseless cases. We expect that this “critical R” is dependent on several factors, including the receiver coil configuration and the number of VFAs. For example, the critical R” is likely to be larger if one uses higher‐density coil arrays that provide greater degrees of freedom in the subspace spanned by the coil sensitivity maps.

We noticed no spatial patterns related to data sampling in the T1 error maps at R ≤ 10 in the healthy volunteer study. There were, however, mild spatial variations in T1 error with tissue type. For instance, we saw negligible error in WM and higher error in CSF. This is consistent with the expected reduction in T1 precision as true T1 increases. The proposed method was successfully applied to a small cohort of patients with high‐grade glioma. The T1 values in BT regions are heterogeneous and are longer than those of WM in the same subjects with values consistent with the literature33, 34, 35 (1392‐3601 ms).

We observed spatial heterogeneity and the presence of sharp features in BT ROI’s. This indicates the need for precontrast T1 mapping to provide equally fine spatial resolution compared with DCE‐MRI and indicates that the use of spatial constraints/regularization could mask these features. Parametric constraints along the FA dimension or appropriately defined low‐rank constraints may be viable. The proposed method allowed clear visualization of postsurgical cavities that have substantially longer T1 values. The proposed method depicted the expected tissue boundaries with high spatial resolution and whole‐brain coverage, providing adequate quality for voxel‐wise quantitative DCE‐MRI. However, we were not able to observe clear boundaries between cellular tumor and cavities, likely because there could be mixture with more complicated T1 characteristics, such as edema.

Error propagation analysis revealed that ±15% error in mean brain‐tumor T1 results in at most 0.008 and 0.007 min−1 (Patlak model), and 0.016 and 0.033 min−1 absolute error extended Tofts‐Kety (ETK) model in the DCE estimated pharmacokinetic parameters, vp and Kt, respectively. However, there are many dependencies, and error propagation depends on the TK model, true T1 and the polarity of the error. TK error is always positively related to precontrast T1 error in the Patlak model; however, the relationships for the ETK model are more complicated as discussed in the Appendix A.

This study has several limitations. First, there is a general lack of commonly accepted glioma T1 values likely because of intertumor heterogeneity because of factors such as tumor grade, age, and treatment. For this reason, realistic simulation of brain tumors in DROs remains challenging and possibly suboptimal in terms of its ability to accurately capture real‐brain DCE‐MRI examinations. This study addresses this with a range of parameter values based on the published literature, and refinement of this approach is subject to future research.

The second limitation consists of only using one healthy subject for in vivo validation of the proposed method. Acquiring fully sampled VFA scans is time consuming, which impedes the generation of larger data sets for this study. For identical reasons, acquiring such scans for patients with brain tumors as the target cohort was not practical because of the severity of the disease and patient unwillingness to consent to such extensive research examinations. Tumor ROIs were directly drawn on the T1 maps to be evaluated, which caused circularity in the patient study that we were unable to avoid.

Failure to account for magnetization transfer (MT) and motion effects is the third limitation of the study. Better accuracy and precision may be achieved by incorporating MT and head motion modeling, or by implementing controlled saturation MT introduced by Teixeira et al.38 An example of showing improved MT‐balanced VFA T1 mapping has been shown by Lee et al.39

The fourth limitation is that the FA settings were not optimized for this application. We used seven FAs logarithmically spaced from 1° to 15° based on the expectation that T1 values in BT ROIs can fall in a broad range. We used a large number of FAs to improve sensitivity over this broad range of T1, but this was not optimized via simulation or phantom experiment.

Finally, the proposed reconstruction involves a nonlinear and nonconvex optimization problem. This is computationally complex and can be numerically unstable. In the prospective study, reconstruction required roughly 3 h per 3D data set, on a computation node of the USC Center for Advanced Research Computing. The long reconstruction time is caused by the recurring gradient computation. This can be potentially shortened with better initial guesses such as low‐resolution estimates of M0 and T1 maps.

In this study, 10‐fold undersampling was found to be the upper bound for adequately accurate precontrast T1 mapping. This result is specific to the body part and disease of interest, and our DCE‐MRI setup, including field strength, receiver coil, and imaging parameters. To apply this approach to a different scanner or body part and disease, we suggest starting with a disease‐appropriate DRO, locally measured coil‐sensitivity profiles, and noise‐covariance measurements. Then repeat the steps in this article to determine the undersampling limit. We have provided software to facilitate this process (see Data Availability Statement).

5. CONCLUSION

We have shown the feasibility of direct precontrast T1 mapping suitable for high‐resolution whole‐brain quantitative DCE‐MRI, with 150 s of VFA scan time. The proposed method is validated in DROs and in one healthy volunteer, and achieved T1 bias ≤ 11 ms and COV ≤ 15% at an undersampling factor of 4. Prospective application to BT patients showed no distinct artifacts, diagnostic image quality, and T1 maps with high definition and with values consistent with the published literature.

CONFLICT OF INTEREST

Coauthor R. Marc Lebel is an employee of GE Healthcare. The authors declare that they have no competing interests.

Supporting information

FIGURE S1 Illustration of Cartesian spiral sampling. Each panel illustrates the (k y, k z) matrix with white dots denoting the phase encodes that are acquired. Flip angles are logarithmically spaced from 1.5° to 15°. An undersampling factor R = 10 is illustrated, which corresponds to 60.48 seconds VFA scan time. Note that 15° is 4 times more densely sampled than other FA’s, for all undersampling factors

ACKNOWLEDGMENTS

The authors thank Sreedevi Gutta, Nam Gyun Lee, and Ye Tian for helpful discussions. The authors gratefully acknowledge funding from the National Institutes of Health (Grant No. R33‐CA225400, principal investigator: Krishna S. Nayak) and the Canadian Cancer Society Research Institute (for patient scanning).

APPENDIX A.

IMPACT OF PRECONTRAST T1 (ERRORS) ON QUANTITATIVE DCE‐MRI (ERRORS)

Here, we summarize the impact of precontrast T1 mapping errors on quantitative dynamic contrast‐enhanced–magnetic resonance imaging (DCE‐MRI) tracer‐kinetic (TK) parameter mapping errors. This is a form of error propagation analysis. DCE‐MRI TK parameters θ, can include Kt, vp, ve, etc., depending on the model used. Here, we examine the Patlak and extended Tofts‐Kety (ETK) models, which are commonly used in brain tumor DCE‐MRI.

DCE‐MRI uses spoiled gradient echo (SPGR) imaging. Consider the steady‐state SPGR signal equation:

DtM0,T1,Ct,α=M01E1tsinα1E1tcosα (A1)

where M0 is the equilibrium magnetization, T1 is the precontrast longitudinal relaxation time, Ct is the contrast agent concentration, α is the flip angle (FA), and E1t=E10eTR·r1Ct with E10=eTR·R1 and R1=1/T1, according to the fast exchange limit (FXL). We can estimate the first‐order error by:

Δθ=θT1ΔT1 (A2)

Therefore, we must evaluate one partial derivative, which is possible using the chain rule:

θT1=i=1NθCtiCtiR1R1T1 (A3)

where θ is the TK parameter of interest, for example, vp or Kt. We are evaluating the dependence on the estimated T1 (and not the DCE scan or vascular input function estimation). Therefore, we compute the partial derivative of estimated concentration (Cti) as a function of precontrast T1, given measured DCE signals as constants. We differentiate both sides of Equation (A1) with respect to (w.r.t. ) to get:Inline graphic

Therefore, we have:

CtiR1=1r1 (A5)

This is the same for all time points. As a result, we have:

θT1=1r1T12i=1NθCti (A6)

Patlak model

Consider first the Patlak model, which is a widely used linear compartment model. According to the Patlak model CA concentration is a linear function of the tracer‐kinetic parameters:

Ct=Cptvp+Kt0tCpτdτ (A7)

where Cpt is the time‐varying contrast agent plasma volume concentration (mM). Cpt is often called the vascular input function (VIF). The function should be determined by sampling the delivery of contrast agent from a vessel directly interacting with the tissue of interest. In this Appendix, three Cpts were either generated from different population‐based models (Parker et al40 and Georgiou et al41) or estimated by averaging multiple in vivo data from our patient DCE‐MRI study. This model can be expressed as a matrix‐vector multiplication, as follows:

Ct=Ct1Ct2CtN=AvpKt (A8)
A=Cpt10t1CpτdτCpt20t2CpτdτCptN0tNCpτdτ (A9)

The solution for vpKt that minimizes the sum of squared residuals (also called the least‐squares solution) is:

vpKt=ACt (A10)

vp and Kt are linear functions of Ct; therefore, all partial derivatives for the least‐squares estimator reside as entries in the A matrix as follows:

vpCtKtCt=vpCt1vpCt2KtCt1KtCt2vpCtNKtCtN=A (A11)

Extended Tofts‐Kety model

As another model widely used in the evaluation of brain tumors, consider the extended Tofts‐Kety (ETK) model, which has a nonlinear dependence on vascular parameters. The ETK model is as follows:

Ct=Cptvp+Kt0tCpτekeptτdτ (A12)

where kep=Ktve is a rate constant.

Although the model nonlinearity does not allow for an explicit solution to the vascular parameter estimator, local first derivatives can be obtained through implicit differentiation or an additional linearization step. In the following, we assume constant ve constant for simplicity.

We take the derivative w.r.t. Cti on both sides of Equation (12) to get:

1=CptivpCti+KtCti0tiCpτekeptiτdτ+KtCtiKt0titiτveCpτekeptiτdτ (A13)

This will convert the nonlinear model of parameters to a linear model of partial derivatives. Thus, we can construct another matrix‐vector multiplication as follows:

1i=AvpCtiKtCti (A14)

In which 1i is a column vector whose ith entry is 1, and

A=Cpt10t11Ktt1τveCpτekept1τdτCpt20t21Ktt2τveCpτekept2τdτCptN0tN1KttNτveCpτekeptNτdτ (A15)

When A is evaluated at some Kt=k, the derivatives are the least‐squares solution to Equation (A14), that is,

vpCtiKtCtiKt=k=A1i (A16)

Alternatively, we can use linear approximation. A continuous and differentiable function fx can be well approximated around x=x~ by

fxdfxdxx=x~x+fx~dfxdxx=x~x~ (A17)

Equation (A12) can be linearly approximated at some Kt=k as follows:

Cti=Cptivp+CtiKtKt=kKt+rk,ti (A18)

In which

CtiKtKt=k=0ti1ktiτveCpτekvetiτdτ (A19)
rk,ti=k0tiCpτekvetiτdτCtiKtKt=kk (A20)

We then can construct another matrix‐vector multiplication such as

Ctrk,t=AvpKt (A21)

In which

A=Cpt1Ct1KtKt=kCpt2Ct2KtKt=kCptNCtNKtKt=k (A22)

Like Equation (A10), the least‐squares solution to Equation (A21) is

vpKtACtrk,t (A23)

Similar to Equation (A11), the derivatives reside as follows:

vpCtiKtCtiKt=k=vpCt1vpCt2KtCt1KtCt2vpCtNKtCtN=A (A24)

Error propagation analysis

Error propagation analysis was performed for the two TK models as outlined in the previous section. The analysis was evaluated with three different VIFs and three different kep values (if necessary) to show the dependencies on them. In addition, all analysis assumed a T1 range of 1700 ± 255 ms, roughly matching the mean T1 of brain tumor in our patient study with ±15% variations.

Figure A1 shows error propagation analysis results in the Patlak model. The first row shows partial derivatives of vp and Kt of precontrast T1 values (1700 ± 255 ms). The second row shows the first‐order error of vp and Kt as a function of ±255 ms (±15%) ΔT1 for the VIFs by Parker et al40 (blue), Georgiou et al41 (red), and the cohort‐based in vivo brain VIF measured at our institution. As the first row shows, partial derivatives were positive and decreased as T1 increased. Consequently, errors in TK parameters were positively related to T1 errors, and T1 error propagation was slower as T1 increased. Quantitatively, a ±255 ms ΔT1 results in ±0.0064, ±0.0043, and ±0.0085 error in vp, and ±0.0074 min−1, ±0.0053 min−1, and ±0.0028 min−1 error in Kt in Parker’s, Georgiou’s, and in vivo measured VIF, respectively.

Figure A2 shows the partial derivatives of vp and Kt of precontrast T1 values (1700 ± 255 ms) in the ETK model. The first row shows the two‐dimensional (2D) plot of partial derivatives of vp. The second row shows the 2D plot of partial derivatives of Kt as a function of both rate constant kep and T1. Like the Patlak model, both derivatives monotonically decreased as T1 increases; however, they are not monotonic functions of kep. Especially for the partial derivative of Kt, it reached its positive extreme at kep approximately 0.64, 0.62, and 0.54 min−1, and had polarity change at kep approximately 1.35, 1.32, and 0.92 min−1.

Figure A3 shows the first‐order error in vp and Kt as a function of ΔT1 in the ETK model in the first and second row, respectively. Errors are plotted for ±255 ms (±15%) ΔT1 for Parker et al’s40 (left), Georgiou et al’s41 (middle), and in vivo measured (right) VIFs. Errors were also evaluated at three different kep values to show dependencies on kep. Δvp was positively related to ΔT1; however, it shrank and then was amplified at kep increases. With ±255 ms ΔT1, Δvp extended to ±0.015, ±0.010, and ±0.016 in maximum at kep = 1.5 min−1 for Parker et al’s, Georgiou et al’s, and in vivo measured VIF, respectively. For ΔKt, the result is more complicated because of the derivative polarity change. With ±255 ms ΔT1, ΔKt extended to ±0.008, ±0.007, and ±0.020 in maximum at kep = 1.5 min−1 for Parker et al’s, Georgiou et al’s, and in vivo measured VIF, respectively. Note that kep = 1.5 min−1 did not necessarily give the maximum ΔKt; however, it was of more interest because high kep values were expected in tumor regions.

Briefly, an error of ±15% in mean brain tumor T1 results in at most 0.008 and 0.007 min−1 absolute error (Patlak model), and 0.016 and 0.033 min−1 absolute error (ETK model) in the DCE‐estimated pharmacokinetic parameters, vp and Kt, respectively.

FIGURE A1.

FIGURE A1

Error analysis in tracer‐kinetic (TK) estimation in the Patlak model. The first row shows partial derivatives of vp and Kt of precontrast T1 values (1700 ± 255 ms). The second row shows the first‐order error of vp and Kt as a function of ±255 ms (±15%) ΔT1. Parker’s (blue), Georgiou’s (red), and in vivo measured (yellow) vascular input functions (VIFs) were analyzed. As the first row shows, partial derivatives were positive and decreased as T1 increased. Consequently, errors in TK parameters were positively related to T1 errors, and T1 error propagation was slower when T1 increased. As the second row shows, a ±255 ms (±15%) ΔT1 results in ±0.0064, ±0.0043, and ±0.0085 errors in vp, and ±0.0074 min−1, ±0.0053 min−1, and ±0.0028 min−1 errors in Kt in Parker’s, Georgiou’s and in vivo measured VIF, respectively

FIGURE A2.

FIGURE A2

Partial derivatives of vp and Kt of precontrast T1 values (1700 ± 255 ms) in the ETK model. The 1st row shows the 2D plot of partial derivatives of vp, and the 2nd row shows the 2D plot of partial derivatives of Kt as a function of both rate constant kep and T1. Like the Patlak model, both derivatives monotonically decreased as T1 increases, however, they are not monotonic functions of kep. Especially for the partial derivative of Kt, it had different polarities depending on kep value

FIGURE A3.

FIGURE A3

The first‐order error in tracer‐kinetic (TK) parameters as a function of ΔT1 in the extended Tofts‐Kety (ETK) model. Errors are plotted for ±255 ms (±15%) ΔT1. The first and second row show the first‐order error of vp and Kt, respectively, and errors were analyzed using Parker’s (left), Georgiou’s (middle), and in vivo measured (right) vascular input function. Errors were also evaluated at three different kep values to show dependencies on kep. For vp, the result is similar to that in Patlak model, whereas it is noticeable that Δvp will be amplified at a higher kep region, for example, tumor. For Kt, the result is more complicated because of the derivative polarity change for different kep

Zhu Z, Lebel RM, Bliesener Y, Acharya J, Frayne R, Nayak KS. Sparse precontrast T1 mapping for high‐resolution whole‐brain DCE‐MRI. Magn Reson Med. 2021;86:2234–2249. 10.1002/mrm.28849

A preliminary version of this work was presented at the International Society for Magnetic Resonance in Medicine 27th Annual Meeting & Exhibition; May 11‐16, 2019; Montreal, Quebec, Canada; Abstract #4544.

Funding information

National Institutes of Health (Grant No. R33‐CA225400; principal investigator: Krishna S. Nayak) and the Canadian Cancer Society Research Institute

DATA AVAILABILITY STATEMENT

The source code for the Sparse Pre‐Contrast T1 Mapping for High‐Resolution Whole‐Brain DCE‐MRI is available at https://github.com/usc‐mrel/SparsePreT1_DCE. The noiseless and 3T‐mimicking noisy brain tumor DRO, the tumor ROI data, and the Cartesian spiral sampling pattern generator used in this work are provided within the same package.

REFERENCES

  • 1.Tofts PS, Brix G, Buckley DL, et al. Estimating kinetic parameters from dynamic contrast‐enhanced t1‐weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging. 1999;10:223‐232. [DOI] [PubMed] [Google Scholar]
  • 2.Sourbron SP, Buckley DL. On the scope and interpretation of the Tofts models for DCE‐MRI. Magn Reson Med. 2011;66:735‐745. [DOI] [PubMed] [Google Scholar]
  • 3.O’Connor JPB, Jackson A, Parker GJM, Roberts C, Jayson GC. Dynamic contrast‐enhanced MRI in clinical trials of antivascular therapies. Nat Rev Clin Oncol. 2012;9:167‐177. [DOI] [PubMed] [Google Scholar]
  • 4.Heye AK, Culling RD, Valdés Hernández MDC, Thrippleton MJ, Wardlaw JM. Assessment of blood‐brain barrier disruption using dynamic contrast‐enhanced MRI. A systematic review. NeuroImage Clin. 2014;6:262‐274. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Law M, Yang S, Babb JS, et al. Comparison of cerebral blood volume and vascular permeability from dynamic susceptibility contrast‐enhanced perfusion MR imaging with glioma grade. Am J Neuroradiol. 2004;25:746‐755. [PMC free article] [PubMed] [Google Scholar]
  • 6.Larsson HBW, Stubgaard M, Frederiksen JL, Jensen M, Henriksen O, Paulson OB. Quantitation of blood‐brain barrier defect by magnetic resonance imaging and gadolinium‐DTPA in patients with multiple sclerosis and brain tumors. Magn Reson Med. 1990;16:117‐131. [DOI] [PubMed] [Google Scholar]
  • 7.Cramer SP, Simonsen H, Frederiksen JL, Rostrup E, Larsson HBW. Abnormal blood‐brain barrier permeability in normal appearing white matter in multiple sclerosis investigated by MRI. NeuroImage Clin. 2014;4:182‐189. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Yang S, Law M, Zagzag D, et al. Dynamic contrast‐enhanced perfusion MR imaging measurements of endothelial permeability: differentiation between atypical and typical meningiomas. AJNR Am J Neuroradiol. 2003;24:1554‐1559. [PMC free article] [PubMed] [Google Scholar]
  • 9.Montagne A, Barnes S, Sweeney M, et al. Blood‐Brain barrier breakdown in the aging human hippocampus. Neuron. 2015;85:296‐302. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999;42:952‐962. [PubMed] [Google Scholar]
  • 11.Uecker M, Lai P, Murphy MJ, et al. ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magn Reson Med. 2014;71:990‐1001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med. 2007;58:1182‐1195. [DOI] [PubMed] [Google Scholar]
  • 13.Lebel RM, Jones J, Ferre J‐C, Law M, Nayak KS. Highly accelerated dynamic contrast enhanced imaging. Magn Reson Med. 2014;71:635‐644. [DOI] [PubMed] [Google Scholar]
  • 14.Guo YI, Lebel RM, Zhu Y, et al. High‐resolution whole‐brain DCE‐MRI using constrained reconstruction: prospective clinical evaluation in brain tumor patients. Med Phys. 2016;43:2013‐2023. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Dickie BR, Banerji A, Kershaw LE, et al. Improved accuracy and precision of tracer kinetic parameters by joint fitting to variable flip angle and dynamic contrast enhanced MRI data. Magn Reson Med. 2016;76:1270‐1281. [DOI] [PubMed] [Google Scholar]
  • 16.Guo Y, Lingala SG, Zhu Y, Lebel RM, Nayak KS. Direct estimation of tracer‐kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI. Magn Reson Med. 2017;78:1566‐1578. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Guo Y, Lingala SG, Bliesener Y, Lebel RM, Zhu Y, Nayak KS. Joint arterial input function and tracer kinetic parameter estimation from undersampled dynamic contrast‐enhanced MRI using a model consistency constraint. Magn Reson Med. 2018;79:2804‐2815. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Lingala SG, Guo YI, Bliesener Y, et al. Tracer kinetic models as temporal constraints during brain tumor DCE‐MRI reconstruction. Med Phys. 2020;47:37‐51. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Fram EK, Herfkens RJ, Johnson GAllan, et al. Rapid calculation of T1 using variable flip angle gradient refocused imaging. Magn Reson Imaging. 1987;5:201‐208. [DOI] [PubMed] [Google Scholar]
  • 20.Look DC, Locker DR. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum. 1970;41:250‐251. [Google Scholar]
  • 21.Lebel RM, Guo Y, Lingala SG, Frayne R, Nayak KS. Highly accelerated DCE imaging with integrated T1 mapping. In: ISMRM 25th Scientific Sessions. Honolulu; 2017, p. 138. [Google Scholar]
  • 22.Maier O, Schoormans J, Schloegl M, et al. Rapid T 1 quantification from high resolution 3D data with model‐based reconstruction. Magn Reson Med. 2019;81:2072‐2089. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Deoni SCL. High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI). J Magn Reson Imaging. 2007;26:1106‐1111. [DOI] [PubMed] [Google Scholar]
  • 24.Deoni SCL, Rutt BK, Peters TM. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med. 2003;49:515‐526. [DOI] [PubMed] [Google Scholar]
  • 25.Larsson C, Kleppestø M, Grothe I, Vardal J, Bjørnerud A. T1 in high‐grade glioma and the influence of different measurement strategies on parameter estimations in DCE‐MRI. J Magn Reson Imaging. 2015;42:97‐104. [DOI] [PubMed] [Google Scholar]
  • 26.Fennessy FM, Fedorov A, Gupta SN, Schmidt EJ, Tempany CM, Mulkern RV. Practical considerations in T1 mapping of prostate for dynamic contrast enhancement pharmacokinetic analyses. Magn Reson Imaging. 2012;30:1224‐1233. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Sutton BP, Noll DC, Fessler JA. Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities. IEEE Trans Med Imaging. 2003;22:178‐188. [DOI] [PubMed] [Google Scholar]
  • 28.Cheng H‐LM, Wright GA. Rapid high‐resolutionT1 mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn Reson Med. 2006;55:566‐574. [DOI] [PubMed] [Google Scholar]
  • 29.Lee Y, Callaghan MF, Nagy Z. Analysis of the precision of variable flip angle T1 mapping with emphasis on the noise propagated from RF transmit field maps. Front Neurosci. 2017;11:106. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Bosca RJ, Jackson EF. Creating an anthropomorphic digital MR phantom—an extensible tool for comparing and evaluating quantitative imaging algorithms. Phys Med Biol. 2016;61:974‐982. [DOI] [PubMed] [Google Scholar]
  • 31.Bliesener Y, Lingala SG, Haldar JP, Nayak KS. Impact of (k, t) sampling on DCE MRI tracer kinetic parameter estimation in digital reference objects. Magn Reson Med. 2020;83:1625‐1639. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med. 2005;54:507‐512. [DOI] [PubMed] [Google Scholar]
  • 33.Müller A, Jurcoane A, Kebir S, et al. Quantitative T1‐mapping detects cloudy‐enhancing tumor compartments predicting outcome of patients with glioblastoma. Cancer Med. 2017;6:89‐99. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Hattingen E, Müller A, Jurcoane A, et al. Value of quantitative magnetic resonance imaging T1‐relaxometry in predicting contrast‐enhancement in glioblastoma patients. Oncotarget. 2017;8:53542‐53551. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Badve C, Yu A, Dastmalchian S, et al. MR fingerprinting of adult brain tumors: initial experience. Am J Neuroradiol. 2017;38:492‐499. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Sacolick LI, Wiesinger F, Hancu I, Vogel MW. B 1 mapping by Bloch‐Siegert shift. Magn Reson Med. 2010;63:1315‐1322. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Zhang Y, Brady M, Smith S. Segmentation of brain MR images through a hidden Markov random field model and the expectation‐maximization algorithm. IEEE Trans Med Imaging. 2001;20:45‐57. [DOI] [PubMed] [Google Scholar]
  • 38.A.G. Teixeira RP, Malik SJ, Hajnal JV. Fast quantitative MRI using controlled saturation magnetization transfer. Magn Reson Med. 2019;81:907‐920. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Lee N, Zhu Z, Nayak KS. Variable flip angle T1 mapping with MT‐balanced RF pulses. In: Proceedings of the ISMRM & SMRT Virtual Conference & Exhibition, 2020, p. 3793.
  • 40.Parker GJM, Roberts C, Macdonald A, et al. Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRI. Magn Reson Med. 2006;56:993‐1000. [DOI] [PubMed] [Google Scholar]
  • 41.Georgiou L, Wilson DJ, Sharma N, Perren TJ, Buckley DL. A functional form for a representative individual arterial input function measured from a population using high temporal resolution DCE MRI. Magn Reson Med. 2019;81:1955‐1963. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

FIGURE S1 Illustration of Cartesian spiral sampling. Each panel illustrates the (k y, k z) matrix with white dots denoting the phase encodes that are acquired. Flip angles are logarithmically spaced from 1.5° to 15°. An undersampling factor R = 10 is illustrated, which corresponds to 60.48 seconds VFA scan time. Note that 15° is 4 times more densely sampled than other FA’s, for all undersampling factors

Data Availability Statement

The source code for the Sparse Pre‐Contrast T1 Mapping for High‐Resolution Whole‐Brain DCE‐MRI is available at https://github.com/usc‐mrel/SparsePreT1_DCE. The noiseless and 3T‐mimicking noisy brain tumor DRO, the tumor ROI data, and the Cartesian spiral sampling pattern generator used in this work are provided within the same package.


Articles from Magnetic Resonance in Medicine are provided here courtesy of Wiley

RESOURCES