Skip to main content
The Saudi Dental Journal logoLink to The Saudi Dental Journal
. 2021 Mar 14;33(6):299–307. doi: 10.1016/j.sdentj.2021.03.002

Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial

Cleber Davi Del Rei Daltro Rosa a,, Rafaella de Souza Leão b, Cátia Maria Fonseca Guerra c, Eduardo Piza Pellizzer a, Bruno Gustavo da Silva Casado b, Sandra Lúcia Dantas de Moraes b
PMCID: PMC8376671  PMID: 34434031

Abstract

Objective

This review is to compare patient-satisfaction with ball-type overdenture attachment systems with others attachment systems.

Material and methods

This study was registered in PROSPERO (CRD42018097234) and adheres the PRISMA guidelines. Electronic searches on PubMed/MEDLINE, Scopus, Cochrane, and Web of Science databases for published articles were performed before October 2020. The PICO question was: “Do patients with a ball-type overdenture retention system have greater satisfaction, when compared to other attachment systems?” The evaluation of risk of bias was performed using the Cochrane risk of bias tool.

Results

After searching the databases, seven articles were selected out of a total of 2583. A total of 312 implants were placed in 139 patients, with a mean age of 65.9 years. The risk of bias in the included studies varied according to the different domains in a risk of uncertain bias or low bias risk. No difference was found between the ball attachment systems and the others systems, with respect to patient-satisfaction. The meta-analysis revealed no statistically significant difference between the ball systems and another systems (P = 0.11; MD: 10.90; 95% CI: −2.55 to 24.35).

Conclusions

Regarding patient general satisfaction, it was not possible to determine differences between the ball system and another types of attachment system for overdenture. The ball-type system was statistically superior only to the magnet system.

Keywords: Overdenture, Denture precision attachment, Patient-satisfaction, Systematic review, Cross-over studies, Prosthodontics

1. Introduction

The principles of osseointegration in dentistry has enabled the emergence of a new perspective for the oral rehabilitation of completely edentulous patients, which include implant overdentures (Melas et al., 2001, Veyrune et al., 2005), in fact overdentures supported by two implants are considered to be the first choice of treatment for completely edentulous patients, according to the consensus of McGill in 2002 (Feine et al., 2002) and the York Consensus Statement with McGill (Thomason et al., 2009).

A wide variety of commercially available attachment systems are used to attach implants to overdentures (Alqutaibi and Kaddah, 2016). However, literature has several contradictory opinions regarding the type of attachment system that would be the most beneficial to the patient (Cicciù et al., 2019).

The ball-type system (O-ring) is one of the most commonly used overdentures, because it has a simple manufacturing technique, can be fabricated at low cost (Sadowsky, 2001), easy to maintain, and easy to keep a good hygiene. It consists of an intermediate with a spherical socket at its end, with the assembly (male component) being attached to the implant, and a female component, which has a retaining ring, associated with the base of the prosthesis. However, there is no strong evidence to prove superiority of this overdenture attachment system over other systems, regarding to patient satisfaction (Carlsson, 2014), mainly when considering the results of crossover studies, effective in reducing confounding factors on cause and effect relationships (Clancy, 2002).

Thus, this systematic review was conducted with the aim of comparing the ball-type attachment system with other systems, with respect to patient satisfaction. The null hypothesis of this study is that there is no difference in patient satisfaction between the ball-type attachment system and other overdenture attachment systems.

2. Materials and methods

2.1. Protocol registry

This systematic review followed the criteria established by PRISMA (Moher et al., 2010), and is registered with the international registration database for systematic reviews, PROSPERO (Reg. no: CRD42018097234).

2.2. Research methods and search strategy

Two investigators (C.D.D.R.D.R and R.S.L) independently performed electronic searches on PubMed/MEDLINE, Scopus, Cochrane and Web of Science databases for articles published prior to October 2020, which met the eligibility criteria.

The keywords used for the search were: “overdenture and satisfaction OR overdenture and ball attachment OR overdenture and nonsplinted attachment OR overdenture and un-splinted attachment”. In addition, a manual search was performed in the following journals: Clinical Oral Implants Research, Journal of Oral Rehabilitation, The Journal of Prosthetic Dentistry, Journal of Prosthodontics, Journal of Dentistry, International Journal of Oral and Maxillofacial Surgery, and the Clinical Oral Investigations journal.

The inter-examiner test (Kappa) was used as an additional analysis to evaluate the researchers' agreement on the titles and abstracts selected for each database (PubMed / MEDLINE, Scopus, Cochrane and Web of Science). All disagreements were analyzed and resolved by a third reviewer (S.L.D.M), and a consensus was established.

2.3. Eligibility criteria

The PICO strategy (population, intervention, comparison, outcome) was used to answer the question: “Do patients with a ball-type overdenture retention system have greater satisfaction, when compared to other systems?”, where “population” referred to patients rehabilitated with overdenture prostheses, “intervention” referred to patients rehabilitated with ball-type overdenture prostheses, “comparison” referred to comparing the overdenture prosthesis with another type of attachment system (bar, magneto, locator and equator), and finally the “outcome” referred to the level of patient satisfaction with these systems.

The inclusion criteria was defined randomized crossover trials with at least 10 participants and at least 6 months of follow-up, and that the study was conducted in the English language, which compared ball retention systems with another type of attachment. Retrospective, in vitro and animal studies, computational studies and case series were the exclusion criteria used.

2.4. Risk of bias and evaluation of study quality

Two investigators (C.D.D.R.D.R. and R.S.L.) evaluated the methodological quality of the studies through the Cochrane risk of bias tool, to assess the risk of quality bias of the studies included for this review. This tool evaluates the quality and risk of bias of the studies based on sequence generation, allocation concealment, blinding of participants, personnel or outcome investigator, incomplete outcome data, selective outcome reporting and other sources of bias, and classified as Low, High or Unclear risk of bias, according to the studies evaluated.

2.5. Data extraction

Qualitative data were collected by one of the authors (C.D.D.R.D.R), and a second author (R.S.L) verified the information. However, due to disagreement between these authors, a third author (S.L.D.M) minutely evaluated the disagreements and a consensus was arrived at, through a discussion.

The following information for each selected study was included in a Microsoft Office Excel table: author, number patient, mean age, number implant for patients, design of study, attachment types, arch (Maxilla / Mandible), implant system and dimensions (mm), satisfaction evaluated methods, outcomes results, conclusion, follow-up, patients preferences.

2.6. Summary measures

Quantitative analysis was performed based on a continuous outcome with the determination of inverse variance (IV) and respective 95% confidence intervals (CI) for the comparison of patient satisfaction (visual analogic scale (VAS) ranging from 0 to 100) to the type of attachment system (ball × another systems). For that it was using the mean difference (MD). The Reviewer Manager v5.4 software program (Nordic Cochrane Centre, Cochrane Collaboration, 2014) was used for the meta-analysis and creation of the forest plots, with a p-value < 0.05 considered indicative of statistical significance.

2.7. Additional analysis

In the meta-analysis, additional subgroup analysis was performed for the other types of attachment systems × ball systems (ball × magneto; ball × locator and ball × bar).

3. Results

A total of 2583 references were found from searches conducted in PubMed (8 9 7), Scopus (7 7 9), Cochrane (2 7 2) and Web of Science (6 6 5), and 13 articles were selected and analyzed fully, after screening the title and abstract. Three references were excluded due to the lack of comparison between the groups (Cune et al., 2010, Bilhan et al., 2011, Van Der Bilt et al., 2006). Three other articles were excluded because: it did not evaluate the general satisfaction of the patient (Pisani et al., 2017), it did not evaluate the attachment ball (Mahanna et al., 2020) and Cune et al., 2006 is not in English. The search strategy is detailed in the flow diagram (Fig. 1).

Fig. 1.

Fig. 1

Search strategy.

The inter-examiner test (kappa) presented a total score of 0.82 for PubMed/MEDLINE; 0.90 for Scopus and 0.93 for The Cochrane Library, and a high level of agreement among reviewers was considered according to the kappa criteria (Landis & Koch, 1977). All the 7 articles selected (Burns et al., 1995: Burns et al., 2011, Cune et al., 2005, Ellis et al., 2009, Krennmair et al., 2012; de Albuquerque et al., 2019; Taha et al., 2019) and randomized crossover clinical trials.

A total of 312 implants were used in 139 patients with a mean age of 65.9 years. All rehabilitations with overdentures were in the mandibular arch. Camlog, Screw-line, Altatec; Brånemark, Nobel Biocare; Frialit-2, Friadent; Calcitek Corp and Titamax, CM Cortical, Neodent Implants were the most widely used implant systems (Table 1).

Table 1.

Summary of characteristics of included studies.

Author Patient (n) Mean age, years Number implant for patients Design of study Attachment types Arch Implant system and dimensions (mm) Satisfaction Evaluated Methods Outcomes Results Conclusion Follow-up, months Preference
Burns et al., 1995 17 61.2 2 RCT CROSSOVER Ball (17)
Magneto (17)
Maxilla: 0
Mandible: 17
Calcitek Corp., Carlsbad, Calif.
D = NR
L = NR
Questionnaire NR NS 12 Ball
Cune et al., 2005 18 45.5 2 RCT CROSSOVER Bar (18)
Ball(18) Magneto(18)
Maxilla: 0 Mandible: 18
Frialit-2, Friadent
D = NR
L = NR
VAS Bar = 85.2 Ball = 86.2 Magneto = 60.2
NS 9 Bar
Ellis et al., 2009 22 64.3 2 RCT CROSSOVER Ball (16)
Magnetos (16)
Maxilla: 0
Mandible: 16
Bra°nemark
Nobel Biocare
D = NR
L = NR
VAS
Ball = 97.0
Magneto = 55.0
Ball is better than magneto in the general satisfaction, stability and ability to chew. 6 Ball
Burns et al., 2011 30 58.9 4 RCT CROSSOVER Bar 4 implants(27) Bar 2 implants(27) Ball 2 implants(27)
Maxilla: 0 Mandible: 27
Brånemark, Nobel Biocare

D = 3.75 mm
L = Varied
Questionnaire of 40 questions
NR NS 36 Ball
Krennmair et al., 2012 20 62.4 2 RCT CROSSOVER Ball (19)
Locator(19)
Maxila:0
Mandible:19
Camlog, Screw-line, Altatec
D = NR
L = NR
VAS Ball=
9.5
Locator=
10.0
NS 12 NR
De Albuquerque et al., 2019 24 73.2 2 RCT CROSSOVER Ball (24)
Locator(24)
Maxila:0
Mandible:24
Straumann implants
D = 4.8
L = NR
VAS Ball = 93.5
Locator = 94.0
Ball is better than Locator in retention. 12 Ball
Taha et al., 2019 18 66.1 1 RCT CROSSOVER Ball (18)
Equator (18)
Maxila:0
Mandible:18
Titamax, CM Cortical, Neodent Implants
D = 3.75
L = 9 mm
11 mm
13 mm
VAS Ball = 85.0
Equator = 91.7
NS 6 Equator

D = diameter; L = length NS = not significant; NR = not related; VAS = visual analog scale.

Five studies used only 2 implants (Burns et al., 1995, Cune et al., 2005, Ellis et al., 2009, Krennmair et al., 2012; de Albuquerque et al., 2019), one study used 4 implants (Burns et al., 2011) and one study used 1 implant (Taha et al., 2019). Overall, 323 overdentures were installed, and all patients received the ball-type system, during treatment. Other fittings used in the studies included 43 overdentures with Locator retention system, 9 overdentures with Equator retention system, 27 overdentures with splint bar in 4 implants, 45 overdentures with splint bar in 2 implants, and 51 overdentures with magnet clamps. The mean follow-up time was 11 months (range: 6–36 months). Qualitative data can be observed in Table 1.

Five studies evaluated patient satisfaction using only the Visual Analogue Scale – VAS (Cune et al., 2005, Ellis et al., 2009, Krennmair et al., 2012; de Albuquerque et al., 2019; Taha et al., 2019). Two studies evaluated patient satisfaction using only a questionnaire (Burns et al., 1995, Burns et al., 2011). Five studies reported that there was no statistically significant difference between attachment systems (Burns et al., 1995: Burns et al., 2011, Cune et al., 2005, Krennmair et al., 2012; Taha et al., 2019); one study (Ellis et al., 2009) showed that there was a statistically significant difference for three domains: general satisfaction (P = 0.024), stability (P = 0.049) and chewing ability (P = 0.024), with the results being higher for the ball attachment group and De Albuquerque et al., 2019 showed Significant differences, in retention domain for ball attachment. For the included studies the meta-analysis revealed no statistically significant difference between the ball systems and another systems (P = 0.11; MD: 10.90; 95% CI: −2.55 to 24.35). Subgroup analysis showed that only the magnet system was statistically different from the ball. (P < 0.00001; MD: 26.08; 95% CI: 16.56–35.59). In addition to these results the analysis of the selected studies (Taha et al., 2019, Burns et al., 1995, Cune et al., 2005, Ellis et al., 2009) showed that there was an increase in patient satisfaction after replacing the conventional full mandibular prosthesis with overdentures regardless of the attachment system.

3.1. Risk of bias

The Cochrane risk of bias tool was used to assess the risk of bias of clinical trials and the outcome is described in Fig. 2 and Fig. 3. This scale presents evaluation by different domains. Only studies with a low or intermediate risk of bias were included in the review. In general, 3 domains (concealment of allocation, blindness of participants and professionals, and blindness of outcome assessors) presented a risk of uncertain bias; however, since the study does not report those information, and additional information is necessary to ascertain the risk of bias. In the other domains (random sequence generation, incomplete outcomes, selective outcome reporting, other sources of bias), at least 50% index was obtained for low bias risk.

Fig. 2.

Fig. 2

The Cochrane scale for bias risk.

Fig. 3.

Fig. 3

Fig. 2. Assessment of the risk of bias in the included studies based on the Cochrane Risk of Bias Tools.

4. Discussion

Patient expectation regarding treatment is a predictor of satisfaction (Jackson et al., 2001, Linder, 1982), in which completely edentulous individuals is related to the retentive capacity of the prostheses. Machado et al, 2017 identified that the factor that damages masticatory function most is the movement of the mandibular prosthesis. Rehabilitation with overdentures, when compared to conventional complete dentures, tend to promote greater patient satisfaction due to their greater functional capacity (Harris et al., 2013, Awad et al., 2014, Geckili et al., 2012, Jabbour et al., 2012).

Treatment satisfaction is a complex phenomenon, which is influenced by numerous factors, and is not strictly related to the stomatognathic system (Al Quran et al., 2001). Currently, there is no consensus on which overdenture retention system provides greater patient satisfaction (Anas El-Wegoud et al., 2018). The results of this systematic review are in agreement with other studies (Naert et al., 1994; Naert et al., 1998; Kleis et al., 2010, Timmerman et al., 2004) that did not detected differences in patient satisfaction between the ball-type system, which is most commonly used, and other attachments, thus accepting the null hypothesis of this study, even though the majority of articles point to a preference for the ball-type system.

Studies that highlighted the main systems (ball, clip and magnetic bar), found that retention, chewing and comfort were the main factors that influenced patient-satisfaction. According to the Meta-analysis (Fig. 4) conducted in this study, there is a significant difference (P < 0.00001) in patient satisfaction when comparing the ball and magnet system, this can be explained by the difference in retention promoted by the systems. Van Kampen et al, found mean retention force for magnetic systems was 8.1 N(Bar-clip 31.3 N and Ball 29.7 N). This result may explain the greater patient satisfaction for the ball system in the work of Ellis et al, 2009 in which patients reported the perception of a difference in retention between the two systems, with the ball attachment system offering better retention than the magnetic system. In the study by Cune et al., 2005 patients preferred the ball attachment system, arguing that the mandibular denture was very stable during chewing and biting. Burns et al, 1995 also reported that the patients with ball-type fitting mentioned greater difficulty in removing the denture, when compared to those patients with the magnetic attachment. One aspect cited in the question “comfort” is the sensation of the abutments when the prostheses are out of the mouth. The ball fit is more prominent and angular and several patients reported a tongue discomfort as a result of the resting sensation over the abutment (Ellis et al, 2009).

Fig. 4.

Fig. 4

Forest plot: comparison of studies evaluating patient satisfaction.

On comparing the Locator and O-ring attachments, there were no significant differences in satisfaction, comfort, speech, aesthetics, chewing ability, or stability of the denture that could be identified (Krennmair et al., 2012). A overall average retention throughout the study was higher for the ball attachment, with a difference of 5.0 N (De Albuquerque et al., 2019), but no preference for one type of attachment versus the other was seen (De Albuquerque et al., 2019; Krennmair et al., 2012).

For patients who preferred the bar-clip attachment, the following issues were important: greater stability during chewing, compared to the magnet and O-ring, and a feeling of reassurance. However, the patients found that sanitization of the bar was harder, and thus a greater chance of marginal bone loss was possible due to peri implant causes (Cune et al., 2005). In this study, the patients reported retention of the attachment system as the main satisfaction factor. Timmerman et al, 2004 also suggested that patient satisfaction was linked to retention and stability of the prosthesis.

Retention and stability are important factors that determine patient satisfaction. Although retention of the prosthesis with O-ring supported by 2 implants is inferior to that of the bar-clip system with 4 implants, parameters such as chewing, phonetics, ease of hygiene, health of the periodontal tissues, maintenance, and complications favor the ball-type attachment, when compared to the bar-type (Burns et al., 2011). These factors, together with the small discrepancy between the retentive capacities of the systems (bar-clip 31.3 N and ball 29.7 N) (Van Kampen et al., 2003) may explain the lack of difference in patient satisfaction for the main systems found this review. There are other factors besides attachment retention in the success of the rehabilitation treatment with implant overdentures and the lack of retention does not prevent patients from eating satisfactorily (de Albuquerque et al., 2019).

In addition, over time, there was a notable increase in the retentive force of the O-ring system, whereas the bar and magnet systems showed a decrease in the retentive force. The increased retentive force in the ball group can be explained by improvement in seating of the overdenture base, that occurs with years of usage, unlike the attachment bar and magnet, which function as an “articulated” device for the overdenture (Naert et al., 2004). Thus, ball-type retentive fittings are known to be advantageous for overdentures with respect to stress optimization, minimizing prosthetic movements (Tokuhisa et al., 2003), simplicity, and fewer complications (Naert et al., 2004).

Crossover-type randomized clinical trials are effective in reducing confounding factors on cause-and-effect relationships when compared to other designs, hence, they are of great value as a source of evidence (Clancy, 2002). In this study, each subject functioned as their own control, and the comparison of the different interventions on intra-subject variation, thus, generating more reliability to the results of this systematic review. In addition, statistically, crossover studies are more powerful than parallel groups (Cleophas and de Vogel, 1998).

The results of this meta-analysis should be viewed with caution, due to the small sample included. In addition, there was a high rate of heterogeneity, which can also be attributed to the small number of studies included in the meta-analysis, which made it impossible to compare all types of attachments. Further clinical trials are necessary to compare all attachments regarding patients satisfaction, to confirm this reviews results

In view of this, it is worth mentioning that in addition to the knowledge about the level of satisfaction of the retention systems, the professional should consider clinical and technical aspects such as implant parallelism, distance between implants, simplicity of the technique, cost, and patient hygiene, among others, that can guide the choice of the type of system to be used (Leão et al., 2018). However, the findings of this review should be analyzed with caution, since qualitative studies of patient satisfaction depends on patients' capacity for comprehension. In addition, a limitation of this meta-analysis is the high heterogeneity of the included studies. Therefore, this study demonstrates the need for further randomized control trial studies on the subject, especially with long follow-up cases, which can also be considered as a limitation of this study.

5. Conclusion

Regarding patient satisfaction general, it was not possible to determine differences between the ball-type system and other types of attachment system for overdenture. The quantitative analysis showed that the ball-type system was statistically superior only to the magnet system.

CRediT authorship contribution statement

Cleber Davi Del Rei Daltro Rosa: Conceptualization, Data curation, Investigation, Writing - original draft. Rafaella de Souza Leão: Conceptualization, Data curation, Investigation, Supervision, Writing - review & editing. Cátia Maria Fonseca Guerra: Methodology, Supervision, Validation. Eduardo Piza Pellizzer: Methodology, Project administration, Validation, Visualization. Bruno Gustavo da Silva Casado: Data curation, Software, Writing - review & editing. Sandra Lúcia Dantas de Moraes: Methodology, Project administration, Supervision, Validation, Visualization, Writing - review & editing.

Declaration of Competing Interest

The authors of the manuscript declare that they have no conflict of interest: financial, commercial, political, academic, personal and no other relationships / conditions / circumstances that present a potential conflict of interest.

Acknowledgments

Acknowledgments

This work had in part the support of the scholarship provided by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil.

Funding

The authors do not have any financial interest in the companies whose materials are included in this article.

Ethics approval

Not applicable.

Footnotes

Peer review under responsibility of King Saud University.

Contributor Information

Cleber Davi Del Rei Daltro Rosa, Email: cleberdavi2@hotmail.com.

Eduardo Piza Pellizzer, Email: ed.pl@uol.com.br.

Sandra Lúcia Dantas de Moraes, Email: sandra.moraes@upe.br.

References

  1. Al Quran F., Clifford T., Cooper C., Lamey P.J. Influence of psychological factors on the acceptance of complete dentures. Gerodontology. 2001;18(1):35–40. doi: 10.1111/j.1741-2358.2001.00035.x. [DOI] [PubMed] [Google Scholar]
  2. Alqutaibi A.Y., Kaddah A.F. Attachments used with implant supported overdenture. Int. Dental Med. J. Adv. Res. 2016;2(1):1–5. [Google Scholar]
  3. Anas El-Wegoud M., Fayyad A., Kaddah A., Nabhan A. Bar versus ball attachments for implant-supported overdentures in complete edentulism: A systematic review. Clin. Implant Dentistry Related Res. 2018;20(2):243–250. doi: 10.1111/cid.12551. [DOI] [PubMed] [Google Scholar]
  4. Awad M.A., Rashid F., Feine J.S., Overdenture Effectiveness Study Team Consortium The effect of mandibular 2-implant overdentures on oral health–related quality of life: an international multicentre study. Clin. Oral Implant Res. 2014;25(1):46–51. doi: 10.1111/clr.12205. [DOI] [PubMed] [Google Scholar]
  5. Bilhan H., Geckili O., Sulun T., Bilgin T. A Quality-of-Life Comparison Between Self-Aligning and Ball Attachment Systems for 2-Implant–Retained Mandibular Overdentures. J. Oral Implantol. 2011;37(sp1):167–173. doi: 10.1563/AAID-JOI-D-10-00070. [DOI] [PubMed] [Google Scholar]
  6. Burns D.R., Unger J.W., Elswick R.K., Jr., Giglio J.A. Prospective clinical evaluation of mandibular implant overdentures: Part II—Patient satisfaction and preference. J. Prosthetic Dentistry. 1995;73(4):364–369. doi: 10.1016/s0022-3913(05)80332-4. [DOI] [PubMed] [Google Scholar]
  7. Burns D.R., Unger J.W., Coffey J.P., Waldrop T.C., Elswick R.K., Jr Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment. J. Prosthetic Dentistry. 2011;106(1):12–22. doi: 10.1016/S0022-3913(11)60088-7. [DOI] [PubMed] [Google Scholar]
  8. Carlsson G.E. Implant and root supported overdentures-a literature review and some data on bone loss in edentulous jaws. J. Adv. Prosthodontics. 2014;6(4):245–252. doi: 10.4047/jap.2014.6.4.245. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Cicciù M., Cervino G., Milone D., Risitano G. FEM analysis of dental implant-abutment interface overdenture components and parametric evaluation of Equator® and Locator® prosthodontics attachments. Materials. 2019;12(4):592. doi: 10.3390/ma12040592. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Clancy M. Overview of research designs. Emergency Med. J.: EMJ. 2002;19(6):546. doi: 10.1136/emj.19.6.546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Cleophas T.J., de Vogel E.M. Crossover studies are a better format for comparing equivalent treatments than parallel-group studies. Pharm. World Sci. 1998;20(3):113–117. doi: 10.1023/a:1008626002664. [DOI] [PubMed] [Google Scholar]
  12. Cune M., Van Kampen F., Van der Bilt A., Bosman F. Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial. J. Prosthetic Dentistry. 2005;94(5):471. [PubMed] [Google Scholar]
  13. Cune M.S., Van Kampen F.M., Van Der Bilt A. Patient satisfaction with different types of implant-retained overdentures in the edentate mandible. Nederlands tijdschrift voor tandheelkunde. 2006;113(10):401. [PubMed] [Google Scholar]
  14. Cune M., Burgers M., van Kampen F., de Putter C., van der Bilt A. Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments. Int. J. Prosthodontics. 2010;23(4) [PubMed] [Google Scholar]
  15. de Albuquerque Jr R.F., Fromentin O., Lassauzay C., Conceição Pereira Saraiva M.D. Patient satisfaction versus retention of implant overdentures with two attachment systems: A randomized trial. Clinical implant dentistry and related research. 2019;21(1):21–31. doi: 10.1111/cid.12675. [DOI] [PubMed] [Google Scholar]
  16. Ellis J.S., Burawi G., Walls A., Thomason J.M. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin. Oral Implant Res. 2009;20(11):1293–1298. doi: 10.1111/j.1600-0501.2009.01810.x. [DOI] [PubMed] [Google Scholar]
  17. Feine J.S., Carlsson G.E., Awad M.A., Chehade A., Duncan W.J., Gizani S. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int. J. Oral Maxillofacial Implants. 2002;17(4):601. [PubMed] [Google Scholar]
  18. Geckili O., Bilhan H., Mumcu E., Dayan C., Yabul A., Tuncer N. Comparison of patient satisfaction, quality of life, and bite force between elderly edentulous patients wearing mandibular two implant-supported overdentures and conventional complete dentures after 4 years. Spec. Care Dentist. 2012;32(4):136–141. doi: 10.1111/j.1754-4505.2012.00258.x. [DOI] [PubMed] [Google Scholar]
  19. Harris D., Höfer S., O'Boyle C.A., Sheridan S., Marley J., Benington I.C. A comparison of implant-retained mandibular overdentures and conventional dentures on quality of life in edentulous patients: a randomized, prospective, within-subject controlled clinical trial. Clin. Oral Implant Res. 2013;24(1):96–103. doi: 10.1111/j.1600-0501.2011.02368.x. [DOI] [PubMed] [Google Scholar]
  20. Jabbour Z., Emami E., De Grandmont P., Rompré P.H., Feine J.S. Is oral health-related quality of life stable following rehabilitation with mandibular two-implant overdentures? Clin. Oral Implant Res. 2012;23(10):1205–1209. doi: 10.1111/j.1600-0501.2011.02289.x. [DOI] [PubMed] [Google Scholar]
  21. Jackson J.L., Chamberlin J., Kroenke K. Predictors of patient satisfaction. Soc. Sci. Med. 2001;52(4):609–620. doi: 10.1016/s0277-9536(00)00164-7. [DOI] [PubMed] [Google Scholar]
  22. Kleis W.K., Kämmerer P.W., Hartmann S., Al-Nawas B., Wagner W. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Clin. Implant Dentistry Related Res. 2010;12(3):209–218. doi: 10.1111/j.1708-8208.2009.00154.x. [DOI] [PubMed] [Google Scholar]
  23. Krennmair G., Seemann R., Fazekas A., Ewers R., Piehslinger E. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial. Int. J. Oral Maxillofac. Implants. 2012;27(6) [PubMed] [Google Scholar]
  24. Landis J.R., Koch G.G. The measurement of observer agreement for categorical data. Biometrics. 1977:159–174. [PubMed] [Google Scholar]
  25. Leão R.S., Moraes S.L.D., Vasconcelos B.C.E., Lemos C.A.A., Pellizzer E.P. Splinted and unsplinted overdenture attachment systems: A systematic review and meta-analysis. J. Oral Rehabil. 2018;45(8):647–656. doi: 10.1111/joor.12651. [DOI] [PubMed] [Google Scholar]
  26. Linder, P., 1982. Social psychological determinants of patient satisfaction: a test of five hypotheses. [DOI] [PubMed]
  27. Machado R.M., Bielemann A.M., Nascimento G.G., de Rezende Pinto L., Cury A.A.D.B., Faot F. Masticatory function parameters in patients with varying degree of mandibular bone resorption. J. Prosthodontic Res. 2017;61(3):315–323. doi: 10.1016/j.jpor.2016.12.002. [DOI] [PubMed] [Google Scholar]
  28. Mahanna F.F., Elsyad M.A., Mourad S.I., Abozaed H.W. Satisfaction and Oral Health-Related Quality of Life of Different Attachments Used for Implant-Retained Overdentures in Subjects with Resorbed Mandibles: A Crossover Trial. Int. J. Oral Maxillofac. Implants. 2020;35(2) doi: 10.11607/jomi.7869. [DOI] [PubMed] [Google Scholar]
  29. Melas F., Marcenes W., Wright P.S. Oral health impact on daily performance in patients with implant-stabilized overdentures and patients with conventional complete dentures. Int. J. Oral Maxillofac. Implants. 2001;16(5) [PubMed] [Google Scholar]
  30. Moher D., Liberati A., Tetzlaff J., Altman D.G. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int. J. Surg. 2010;8(5):336–341. doi: 10.1016/j.ijsu.2010.02.007. [DOI] [PubMed] [Google Scholar]
  31. Naert I., Quirynen M., Hooghe M., van Steenberghe D. A comparative prospective study of splinted and unsplinted Brȧnemark implants in mandibular overdenture therapy: A preliminary report. J. Prosthetic Dentistry. 1994;71(5):486–492. doi: 10.1016/0022-3913(94)90188-0. [DOI] [PubMed] [Google Scholar]
  32. Naert I., Gizani S., Vuylsteke M., Van Steenberghe D. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri-implant outcome. Clin. Oral Implant Res. 1998;9(3):170–177. doi: 10.1034/j.1600-0501.1998.090304.x. [DOI] [PubMed] [Google Scholar]
  33. Naert I., Alsaadi G., Quirynen M. Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study. Int. J. Prosthodontics. 2004;17(4) [PubMed] [Google Scholar]
  34. Pisani M., Bedos C., da Silva C.H.L., Fromentin O., de Albuquerque Jr R.F. A qualitative study on patients' perceptions of two types of attachments for implant overdentures. J. Oral Implantol. 2017;43(6):476–481. doi: 10.1563/aaid-joi-D-17-00166. [DOI] [PubMed] [Google Scholar]
  35. Sadowsky S.J. Mandibular implant-retained overdentures: a literature review. J. Prosthetic Dentistry. 2001;86(5):468–473. doi: 10.1067/mpr.2001.119921. [DOI] [PubMed] [Google Scholar]
  36. Taha N.E.K.S., Dias D.R., Oliveira T.M.C., Souza J.A.C., Leles C.R. Patient satisfaction with ball and Equator attachments for single-implant mandibular overdentures: a short-term randomized crossover clinical trial. J. Oral Rehabil. 2019 doi: 10.1111/joor.12895. [DOI] [PubMed] [Google Scholar]
  37. Timmerman R., Stoker G.T., Wismeijer D., Oosterveld P., Vermeeren J.I.J.F., Van Waas M.A.J. An eight-year follow-up to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures. J. Dent. Res. 2004;83(8):630–633. doi: 10.1177/154405910408300809. [DOI] [PubMed] [Google Scholar]
  38. Tokuhisa M., Matsushita Y., Koyano K. ln Vitro Study of a Mandibular Implant Overdenture Retained with Ball, Magnet, or Bar Attachments: Comparison of Load Transfer and Denture Stability. Int. J. Prosthodontics. 2003;16(2) [PubMed] [Google Scholar]
  39. Thomason J.M., Feine J., Exley C., Moynihan P., Müller F., Naert I. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement. Br. Dent. J. 2009;207(4):185–186. doi: 10.1038/sj.bdj.2009.728. [DOI] [PubMed] [Google Scholar]
  40. Van Der Bilt A., Van Kampen F.M., Cune M.S. Masticatory function with mandibular implant-supported overdentures fitted with different attachment types. Eur. J. Oral Sci. 2006;114(3):191–196. doi: 10.1111/j.1600-0722.2006.00356.x. [DOI] [PubMed] [Google Scholar]
  41. Van Kampen F., Cune M., Van Der Bilt A., Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin. Oral Implant Res. 2003;14(6):720–726. doi: 10.1046/j.0905-7161.2003.00961.x. [DOI] [PubMed] [Google Scholar]
  42. Veyrune J.L., Tubert-Jeannin S., Dutheil C., Riordan P.J. Impact of new prostheses on the oral health related quality of life of edentulous patients. Gerodontology. 2005;22(1):3–9. doi: 10.1111/j.1741-2358.2004.00048.x. [DOI] [PubMed] [Google Scholar]

Articles from The Saudi Dental Journal are provided here courtesy of Elsevier

RESOURCES