Abstract
Sera were tested in 2 series both by the conventional technique (dilution in tubes) and by the microtiter system. In 1 series of comparative examinations the tests were performed with the same batch of accessory factor serum and antigen preparation, and in another series the tests were performed at 2 different laboratories. There was a high correlation between the 2 methods, but the titres obtained by the microtiter system were about 1 to 2 twofold dilutions lower than those obtained by the conventional dilution technique. The 95 % confidence limits by the microtiter system were plus and minus 1 twofold dilution.
Keywords: toxoplasma infection, serological technique, sheep
Full Text
The Full Text of this article is available as a PDF (761.5 KB).
References
- Aagaard K. Laboratory methods for the diagnosis of congenital toxoplasmosis. In: Slim J C, editor. Human Toxoplasmosis. 1960. pp. 206–210. [Google Scholar]
- Beverley J K A, Beattie C P. Standardization of the dye test for toxoplasmosis. J. din. Path. 1952;5:350–353. doi: 10.1136/jcp.5.4.350. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Engelbrecht E. The different tests for toxoplasmosis: reproducibility, margins of error and diagnostic meaning. In: Hentsch D, editor. Toxoplasmosis. Bern: Hans Huber Publishers; 1971. pp. 25–60. [Google Scholar]
- Evans A S. Serological techniques. In: Paul J R, White G, editors. Serological Epidemiology. New York and London: Acad. Press; 1973. pp. 41–54. [Google Scholar]
- Feldman H A, Lamb G A. A micromodification of the Toxoplasma dye test. J. Parasit. 1966;52:415. doi: 10.2307/3276516. [DOI] [Google Scholar]
- Folkers C. Evaluation of Aagaard’s method on the search for activator sera for the Sabin-Feldman test in toxoplasmosis. Nature (Lond.) 1964;202:307. doi: 10.1038/202307a0. [DOI] [PubMed] [Google Scholar]
- Kâss E. Toxoplasma and toxoplasmosis. 1954. Unders0kelser over Toxoplasma og toxoplasmose. [Google Scholar]
- Lelong M &, Desmonts G. L’emploi du microscope à contraste de phase dans la réaction de Sabin-Feldman. (Phase contrast microscopy in Sabin and Feldman’s dye test) G.R. Soc. Biol. (Paris) 1951;145:1660–1661. [PubMed] [Google Scholar]
- Palm G, Westphal A, Bimmer E. Zur Technik der Titereinstellung heim Toxoplasma-Serofarbtest. (On the technique of titer adjustment for the toxoplasma-sero-dye test) Zbl. Bakt., I. Abt. Orig. 1958;171:202–214. [PubMed] [Google Scholar]
- Sabin A B, Feldman H A. Dyes as microchemical indicators of a new immunity phenomenon affecting a protozoan parasite (Toxoplasma) Science. 1948;108:660–663. doi: 10.1126/science.108.2815.660. [DOI] [PubMed] [Google Scholar]
- Takátsy G. Hungarian Scientific Instruments. 1967. Use and field of application of a modified microtitrator apparatus; pp. 10–18. [Google Scholar]
- Te Punga W A, Penrose M E. Toxoplasmosis: the effect of citrate, calcium and magnesium ions on the non-specific activity in human sera. N.Z. vet. J. 1965;13:11–14. doi: 10.1080/00480169.1965.33582. [DOI] [PubMed] [Google Scholar]
- Tonder O. Personal communication. 1968. [Google Scholar]