PLHI-MC10: A dataset of exercise activities captured through a triple synchronous medically-approved sensor

Yohan Mahajan a,, Ananth Bhimireddy a, Areeba Abid b, Judy W Gichoya b, Saptarshi Purkayastha a
PMCID: PMC8397882  PMID: 34485637

Abstract

Most human activity recognition datasets that are publicly available have data captured by using either smartphones or smartwatches, which are usually placed on the waist or the wrist, respectively. These devices obtain one set of acceleration and angular velocity in the x-, y-, and z-axis from the accelerometer and the gyroscope planted in these devices. The PLHI-MC10 dataset contains data obtained by using 3 BioStamp nPoint® sensors from 7 physically healthy adult test subjects performing different exercise activities. These sensors are the state-of-the-art biomedical sensors manufactured by MC10. Each of the three sensors was attached to the subject externally on three muscles-Extensor Digitorum (Posterior Forearm), Gastrocnemius (Calf), and Pectoralis (Chest)-giving us three sets of 3 axial acceleration, two sets of 3 axial angular velocities, and 1 set of voltage values from the heart. Using three different sensors instead of a single sensor improves precision. It helps distinguish between human activities as it simultaneously captures the movement and contractions of various muscles from separate parts of the human body. Each test subject performed five activities (stairs, jogging, skipping, lifting kettlebell, basketball throws) in a supervised environment. The data is cleaned, filtered, and synced.

Keywords: Human activity recognition, Accelerometer, Gyroscope, Electrode values

Specifications Table

Subject Health and medical sciences: Sports science, therapy and medicine.
Specific subject area Human Activity Recognition
Type of data Table
How data were acquired Instruments: Wearable sensors (accelerometer, gyroscope, and electrode values).
Make and model of the instruments used: MC10 Inc. BioStamp nPoint® sensors.
Data format Raw
Analyzed Filtered
Parameters for data collection The frequency of data collection for accelerometer and gyroscope embedded in the Extensor Digitorum and Gastrocnemius sensors is 62.5 Hz, whereas the frequency of data collection for accelerometer and electrode embedded in the Pectoralis sensor is 31.25 Hz and 250 Hz, respectively.
Description of data collection Each of the 7 subjects performed all 5 activities in a supervised environment while wearing the biomedical activity sensors. The exact start and end times of each activity were accurately recorded.
Data source location Research lab: Purkayastha Lab for Health Innovation (PLHI).
Institution: Indiana University-Purdue University Indianapolis. City/Town/Region: Indianapolis.
Country: United States of America.
Data accessibility Repository name: GitHub
Data URL: https://github.com/iupui-soic/plhi-mc10

Value of the Data

  • This data contains synchronous motion and muscle measurements at 3 points on the body (back of the forearm, upper calf muscle, chest) for a range of body types. This heterogeneous data is useful for the classification and recognition of various activities [1].

  • The data helps detect and/or classify daily activities and sports (e.g., detecting jogging, counting free throws, etc.) from wearable sensors. Researchers may also use it to validate algorithms (classification, clustering, or others) [2].

  • The time-series data can be analyzed and further processed to extract identifying features of various activities. Additionally, it can be used to develop and validate classification algorithms for activity recognition [3].

  • Educators may use this dataset to train students in data mining or machine learning.

1. Data Description

BioStamp nPoint® is an FDA 510(k) cleared medical device designed to collect medical-grade, clinical quality biometric, physiological, and electronic clinical outcomes assessment (eCOA) data [4]. Data collection was approved by Indiana University's Institutional Review Board (IRB: #2010321996).

1.1. Raw data

The raw data directory consists of 7 sub-directories. Each one of these sub-directories consists of data collected from each subject. Every subject has 3 folders, each corresponding to one of the three BioStamp nPoint® sensors attached to the subject's body. These folders are named according to the muscles where the sensor was attached - Extensor Digitorum (posterior forearm), Gastrocnemius (calf), and Pectoralis (chest).

Both Extensor Digitorum and Gastrocnemius sensors consist of embedded accelerometer and gyroscope whose reading is stored in two different files - accel.csv and gyro.csv, respectively. The frequency of data collection for both, accelerometer and gyroscope is 62.5 Hz and the data collected is along all the 3 axes.

The Pectoralis sensor captures accelerometer and electrode value readings. Like the Extensor Digitorum and Gastrocnemius sensors, accelerometer readings are collected along the 3 axes, as shown in Table 1. The accelerometer readings can be found in the file accel.csv, whereas electrode values are in elec.csv. The frequency of data collection of the accelerometer and electrode values is 31.25 Hz and 250 Hz, respectively. Each data point collected by each sensor is associated with a timestamp, indicating the exact time in microseconds at which the particular data point was generated.

Table 2.

Gyroscope.

Attributes Data Type Description
Timestamp (microseconds) Timestamp Time in GMT Unix Epoch microseconds
Gyro X (Â °/s) Float Gyroscope values in degrees per second
Gyro Y (Â °/s) Float Gyroscope values in degrees per second
Gyro Z (Â °/s) Float Gyroscope values in degrees per second

Table 3.

Electrode values.

Attributes Data Type Description
Timestamp (microseconds) Timestamp Time in GMT Unix Epoch microseconds
Sample (V) Float Voltages values in Volts

Table 4.

Metadata.

Attributes Data Type Description
Activity String Activity Label
Starting Time Timestamp The start time of activity in EST
Elapsed Time Integer The time taken to complete each activity in seconds

Table 1.

Accelerometer.

Attributes Data Type Description
Timestamp (microseconds) Timestamp Time in GMT Unix Epoch microseconds
Accel X (g) Float Acceleration values in G's
Accel Y (g) Float Acceleration values in G's
Accel Z (g) Float Acceleration values in G's

1.2. Metadata

As every subject performed a set of five predetermined activities, the exact start time and the time taken to complete each activity were recorded. This information helped in labeling every data point with one of the five activity labels. Since the number of subjects for this experiment was seven, there are seven metadata files, one for each subject.

1.3. Demographic data

Table 5 shows description and structure of the demographic data.

Table 5.

Demographic data.

Attributes Data Type Description
Subject ID Integer Subject identifier
Gender String Gender of the subject
Age Integer Age of the subject in years
Weight Integer Weight of the subject in pounds (lbs)
Height String Height of the subject in feet+inches

1.4. Filtered data

A filtered table (Table 6) is constructed by adding activity labels to each table (accel.csv, gyro.csv, and elec.csv) from each sensor, for every subject with the help of metadata tables provided for each subject. The readings from all the sensors are then merged. The merged data from all the subjects are then concatenated to get the final filtered table.

Table 6.

Filtered data.

Attributes Data Type
Subject ID Integer
Timestamp (microseconds) Timestamp
Accel X (g) leg Float
Accel Y (g) leg Float
Accel Z (g) leg Float
Gyro X (Â °/s) leg Float
Gyro Y (Â °/s) leg Float
Gyro Z (Â °/s) leg Float
Accel X (g) hand Float
Accel Y (g) hand Float
Accel Z (g) hand Float
Gyro X (Â °/s) hand Float
Gyro Y (Â °/s) hand Float
Gyro Z (Â °/s) hand Float
Accel X (g) chest Float
Accel Y (g) chest Float
Accel Z (g) chest Float
Sample (V) Float
Activity Label String

The final filtered table has more than 142 K data points with 19 attributes. The data in the filtered table is un-normalized and un-standardized.

1.5. Data statistics

Data Statistics table provides the descriptive statistical information of the entire filtered dataset. It gives us the count of data points, mean, standard deviation, minimum value, 25th percentile, 50th percentile, 75th percentile and the maximum value for each activity, captured by each sensor. Table 7 depicts the subset of the actual data statistics, which can be found on the repository, which illustrates all the above mentioned statistical features across all the five activities, captured by the Accel X (g) leg sensor.

Table 8.

Activities.

Activity Instructions
Stairs Climb up and down two flights of stairs, two times.
Jogging Jog for 150 m
Skipping 20 rounds of skipping
Kettlebell 10 curls and 10 rounds
Basketball throws 10 throws and catches of basketball

Table 7.

Data statistics.

Sensor Statistical
Atrribute
Basket
Ball
Jog Kettle
Bell
Skippings Stairs
Accel X
(g) leg
Count 28218 37763 18445 9003 48644
Accel X
(g) leg
Mean 0.70 0.50 0.78 0.56 0.53
Accel X
(g) leg
STD 0.67 1.32 0.58 1.60 1.20
Accel X
(g) leg
Min -1.34 -4.00 -1.48 -4.00 -4.00
Accel X
(g) leg
25% 0.92 -0.41 0.92 -0.33 -0.34
Accel X
(g) leg
50% 0.98 0.75 0.98 0.82 0.82
Accel X
(g) leg
75% 0.99 1.29 0.99 1.26 1.22
Accel X
(g) leg
Max 4.00 4.00 2.64 4.00 4.00

2. Experimental Design, Materials and Methods

2.1. Experimental setup

Most of the Human Activity Recognition datasets publicly present [5,6] out there are generated by using either smartphones or smartwatches. Both these devices has a single pair of accelerometer and gyroscope, with 3 axis along -x, -y and -z each. Also, the smartwatches are located on the wrist and the smartphones are usually in kept in the pockets by the chest or waist. Our proposed dataset is collected using a triple synchronous sensors that provides us with reading from 3 different human body points, unlike smartwatches and smartphones that just provides reading from one point. The activities performed by the subjects in the existing datasets are as simple as standing, walking, lying down, etc., whereas on the other hand, the activities we selected for the proposed dataset were more intense and of varying vigor.

This experiment was conducted on 7 healthy adults in the age range of 20 to 40 years, with 4 female and 3 male subjects. Every subject involved in the experiment performed a set of predetermined activities in a supervised environment while wearing the sensors, as shown in Fig. 1.

Fig. 1.

Fig 1

Positioning of the sensors.

The sensors used for this experiment were BioStamp nPoint® sensors manufactured by MC10 Inc., a wearable health technology and devices manufacturer. These sensors are externally attached to the skin with the help of the BioStamp adhesive, which contains a gel that amplifies the sensor's electric signals [7]. In our experiment, we made use of three such BioStamp nPoint® sensors. One sensor was attached to the left Pectoralis muscle that gave us the accelerometer and electrode values readings. The other two sensors are attached to the Extensor Digitorum and Gastrocnemius muscles of the subject's dominant side. These two sensors provide the accelerometer and gyroscope values.

Table 7 shows the list of 5 activities performed by all seven subjects along with their description. Each subject was thoroughly supervised, and the start time and time taken to complete each activity in seconds were noted for precision with a stopwatch. Any issues with the activity were purged and the activity was re-performed.

2.2. Data cleaning and filtering

We created a python script to filter out the data points that lie outside the time window recorded for every activity using the starting time and elapsed time from every subject's metadata. Using the same metadata, we added the corresponding activity name to each data point to the new activity label column along with the subject ID.

Data obtained from the accelerometer and gyroscope of the sensors attached to the Extensor Digitorum and Gastrocnemius muscles are saved into two different files. Since the frequency of data collection for both, accelerometer and gyroscope is the same for both these sensors, the data points collected are at the exact same time. So, both these files were merged by a simple inner join operation on the timestamp column of the data.

Unlike Extensor Digitorum and Gastrocnemius muscles, the frequency for data collection for accelerometer and electrode values in Pectoralis muscle sensor is different [8]. Due to this, merging these two tables is not as simple as merging accelerometer and gyroscope readings. In this situation, for every data point from the accelerometer reading, we found the closest data point from the electrode values with respect to time. To do this, we subtracted each accelerometer's timestamp value from all the electrode values’ timestamp and selected the data point with the smallest absolute difference, giving us a one-to-one mapping.

We then concatenated the merged tables of each subject together to give us a single table for every sensor (Extensor Digitorum, Gastrocnemius, and Pectoralis). As the final step of data filtering and cleaning, we merged the readings from all three sensors. Extensor Digitorum and Gastrocnemius were merged with an inner join operation, as their frequency is the same. Since the frequency of Pectoralis muscle sensor is different from that of Extensor Digitorum and Gastrocnemius, we performed mapping of Pectoralis sensor values to the data points from Extensor Digitorum and Gastrocnemius by subtracting it's timestamp from Pectoralis timestamp and selecting the data point with the smallest absolute difference, like we did for merging Pectoralis's accelerometer and electrode values.

Ethics Statement

The data is collected from seven anonymous healthy adult subjects after a valid consent received from all of them. IU IRB: #2010321996

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships which have, or could be perceived to have, influenced the work reported in this article.

Acknowledgments

We thank all the subjects who volunteered for the experiment.

References

  • 1.Meurisch C., Schmidt B., Scholz M., Schweizer I., Mühlhäuser M. Proceedings of the Adjunct 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2015 ACM International Symposium on Wearable Computers. 2015. Labels: quantified self app for human activity sensing; pp. 1413–1422. [Google Scholar]
  • 2.Oluwalade B., Neela S., Wawira J., Adejumo T., Purkayastha S. Proceedings of the 14th International Joint Conference on Biomedical Engineering Systems and Technologies-Volume 4. HEALTHINF,, INSTICC, SciTePress; 2021. Human activity recognition using deep learning models on smartphones and smartwatches sensor data; pp. 645–650. [Google Scholar]
  • 3.Yang J.B., Nguyen M.N., San P.P., Li X.L., Krishnaswamy S. Proceedings of the 24th International Conference on Artificial Intelligence. 2015. Deep convolutional neural networks on multichannel time series for human activity recognition; pp. 3995–4001. [Google Scholar]
  • 4.Sen-Gupta E., Wright D.E., Caccese J.W., Wright Jr J.A., Jortberg E., Bhatkar V., Ceruolo M., Gha ffari R., Clason D.L., Maynard J.P. A pivotal study to validate the performance of a novel wearable sensor and system for biometric monitoring in clinical and remote environments. Digital Biomark. 2019;3:1–13. doi: 10.1159/000493642. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Anguita D., Ghio A., Oneto L., Parra X., Reyes-Ortiz J.L. Proceedings of the European Symposium on Artificial Neural Networks, Computational Intelligence and Machine Learning (ESANN) 2013. A public domain dataset for human activity recognition using smartphones. [Google Scholar]
  • 6.Weiss G.M., Yoneda K., Hayajneh T. Smartphone and smartwatch-based biometrics using activities of daily living. IEEE Access. 2019;7:133190–133202. [Google Scholar]
  • 7.Ray T., Choi J., Reeder J., Lee S.P., Aranyosi A.J., Gha ffari R., Rogers J.A. Soft, skin-interfaced wearable systems for sports science and analytics. Curr. Opin. Biomed. Eng. 2019;9:47–56. [Google Scholar]
  • 8.Gorski M.A., Mimoto S.M., Khare V., Bhatkar V., Combs A.H. Real-time digital biometric monitoring during elite athletic competition: System feasibility with a wearable medical-grade sensor. Digital Biomark. 2021;5:37–43. doi: 10.1159/000513222. [DOI] [PMC free article] [PubMed] [Google Scholar]