Abstract

The incidence aortic valve injury during percutaneous coronary intervention is scarce, mostly resulting in acute aortic regurgitation. However, rarely patients may remain asymptomatic in the immediate post-procedure period and present latter with chronic aortic regurgitation. Determining etiology of such an aortic regurgitation may be challenging. We present a case of a 51-year-old man with history of percutaneous coronary intervention for coronary artery disease and moderate aortic regurgitation scheduled for coronary artery bypass grafting and aortic valve replacement. Intra-operative transesophageal echocardiography was instrumental in deciding etiology of aortic regurgitation that change surgical management of the patient.

Keywords: Aortic regurgitation, iatrogenic aortic valve injury, transesophageal echocardiography

INTRODUCTION

Aortic valve injury is a rare complication during percutaneous coronary intervention, with reported incidence of 0.008%-0.20%.[1] A handful of cases have been reported in the past, mostly causing acute decompensation due to injury to the aortic valve leaflets;[1,2,3,4,5,6,7] however, rarely such injury may get unnoticed in the acute phase and present as chronic aortic regurgitation. We describe a 51-year-old man with history of coronary artery stenting 2 years back was scheduled for coronary artery bypass grafting and aortic valve replacement for coronary artery disease and moderate aortic regurgitation. Intraoperative TEE was instrumental in detecting unusual cause of aortic regurgitation that changed the management plan.

CASE REPORT

A 51-year-old man, weight 55 kg, height 160 cm, with known coronary artery disease presented to our outpatient department with complaints of easy fatiguability, dyspnea on exertion and palpitations for one year. He had undergone stenting of left anterior descending (LAD) and left circumflex (LCX) coronary artery 2 years back following which he remained asymptomatic until current presentation. He had associated hypertension and hypothyroidism for 10 years and 5 years, respectively, those were controlled on Metoprolol and Levothyroxine. His general physical examination was unremarkable. Auscultation of chest revealed a grade II diastolic murmur at the apex and normal breath sounds. The electrocardiogram showed sinus bradycardia and features of left ventricular hypertrophy. Chest X-ray showed cardiomegaly with predominant left ventricular enlargement. Preoperative transthoracic echocardiogram done before 2nd coronary angiography showed a moderate aortic regurgitation secondary to cusp prolapse, concentric left ventricle hypertrophy with normal left ventricular systolic and diastolic functions and no regional wall motion abnormality. The left ventricle ends diastolic (LVIDd) and end systolic internal dimensions (LVIDs) were 63 mm and systolic 48 mm, respectively. Coronary angiography showed diffusely diseased proximal LAD with patent stents in the LCX and LAD coronary arteries. The patient was scheduled for a single vessel coronary artery bypass grafting with aortic valve replacement.

In the operating room, after instituting standard monitoring, general anesthesia was induced as per standard protocol of our institute. An adult transesophageal echocardiography (TEE) probe 9T, 3-10 MHz (Vivid E9, GE, USA) was inserted after securing the airway. The TEE examination showed a freely mobile mass on the undersurface of left coronary (LCC) or non-coronary cusp (NCC) with a normal right coronary cusp (RCC) [Figure 1a]. Detailed examination showed flail aortic valve segment of NCC or LCC in the mid-esophageal aortic valve long axis view [Figure 1b and Video 1]. The color Doppler showed a severe eccentric aortic regurgitation jet away from the mitral valve. The mid-esophageal aortic valve short axis view revealed jets arising from the flail NCC and normal RCC and LCC [Figure 1c]. This was further confirmed by 3D-modified mid-esophageal five-chamber view [Figure 1d]. Based on TEE finding and absence of clinical evidence of infective endocarditis, surgeons were informed about the possibility of laceration due to traumatic injury and potential role of aortic valve repair.

Figure 1.

Figure 1

Transesophageal echocardiographic mid esophageal aortic valve long axis view showing a flail segment originating either from NCC or LCC and normal RCC (a); with resulting severe aortic regurgitation jet directed away from mitral valve (b); mid esophageal aortic valve short axis view showing regurgitation jet originating from NCC (c); 3D- modified mid esophageal five- chamber view showing the flail segment originating from aortic valve cusp adjacent to mitral valve (d)

Surgery proceeded following heparinization and institution of CPB using aortic and two staged venous cannulation. Cardioplegic arrest of the heart was achieved using combined antegrade-retrograde cardioplegia. Intraoperative surgical finding following aortotomy confirmed a linear tear in the free margin of NCC, normal RCC and LCC and no evidence of infective endocarditis [Figure 2a]. Using pericardial patch, a neo aortic cusp creation for NCC and a left internal mammary artery to left anterior descending artery coronary artery bypass grafting was performed [Figure 2b]. The patient was weaned off CPB using milrinone 0.3 mcg/kg/min and noradrenaline 0.05 mcg/kg/min. The post CPB, TEE showed normal aortic valve cusp movement [Videos 1 and 2], mild central aortic regurgitation (vena contracta 3 mm) and normal left ventricular systolic (ejection fraction 54%) [Figure 3a, b and Video 2]. The aortic valve cusp coaptation height measured was 7 mm. The patient had an uncomplicated post-operative course. He was extubated of elective mechanical ventilation after 12 hours, discharged from intensive care unit on day third and from hospital on day five. The patient has been in regular follow up since last 7 months after surgery and has been doing well.

Figure 2.

Figure 2

Intraoperative surgical photograph showing lacerated upper margin of the noncoronary cusp (a) with normal right and left coronary cusp; reconstructed neoaortic cusp of the aortic valve (b)

Figure 3.

Figure 3

Post-repair, mid esophageal aortic valve short axis view showing normal opening of aortic valve (a) and mild aortic regurgitation in the midesophageal aortic valve long axis view (b)

DISCUSSION

The aortic leaflet perforations remain a rare but serious complication associated with percutaneous coronary intervention.[1,2,3,4,5,6,7,8,7] The central position of the valve makes it more likely to iatrogenic injuries during percutaneous interventions.[6] These injuries are caused by the multiple passages of stiff guidewires[1,5,6] or, protrusion of a right coronary artery ostium stent onto the valve.[2,3,4,7] Transient aortic regurgitations have also been reported due to excessive movement of a rigid catheter in the aorta.[6] The congenital fenestrations are located in the para-commissural area in the coaptation zone of the aortic valve leaflet and do not directly result in valve insufficiency when they are intact. However, a guidewire induced rupture of the congenital fenestration may cause an acute aortic regurgitation.[8] In the previous reports, the right coronary cusp was the most commonly involved, probably due to the right ostial stent protrusion. In our patient, intraoperative TEE was helpful in localizing the origin of the regurgitation jet to the NCC.

The injured leaflet fragments may also be mimicked by papillary fibroelastomas. The papillary fibroelastomas are typically small tumors of about 9–12 mm in diameter mostly found on the ventricular surface of aortic valve. Typically they do not cause severe aortic insufficiency unless become entrapped in the valve apparatus; however, they can break away and embolize to the brain, causing strokes.[9] On echocardiography, they usually appear pedunculated and mobile, with a homogeneous speckled pattern and characteristic stippling along their edges.[10] In contrast to this, in our case, TEE findings were more suggestive of fail segment of aortic cusp as freely mobile mass moved above and below the aortic annulus during systole and diastole, respectively. An infective endocarditis vegetation might have a similar echocardiography finding; however, in our case there was no clinical evidence of infective endocarditis and on TEE we could appreciate normal RCC, LCC and part of NCC while some part of NCC was freely mobile. Intraoperatively, we found clean straight tears on the NCC, without the presence of any root abscess or commissural tears.

Most of the traumatic aortic valve injury present as acute aortic regurgitation with feature of low cardiac output and heart failure. This complication usually requires immediate attention; however, in the present case, it remained unnoticed until he reached to the operating room after about 2 years of initial percutaneous intervention. This might have occurred because of smaller injury during the first percutaneous coronary intervention causing laceration which might have progressed overtime or, due to a secondary insult during 2nd coronary angiogram.

The single aortic cusp reconstruction for aortic regurgitation is a sparingly used technique, especially in adults. Odim et al. and Tao et al. have demonstrated a relatively high success rates of this procedure with less than grade 2 residual regurgitation.[11,12] Their patients were either children or young adults with congenital aortic valve diseases, unlike ours middle-aged adult with iatrogenic tear of the valve leaflet. The cusp reconstruction was feasible in our patient because of the single leaflet involvement and the absence of calcification which could have posed difficulty in suturing the cusp to the aortic annulus. In addition to diagnosing pathological abnormality, TEE is also very useful in the evaluation of adequacy of valvular reconstruction. The ideal post-operative goal following valve reconstruction is to have a flexible valve that opens well and is competent without any residual insufficiency. In addition, inter-cusp coaptation length >4 mm with an individual cusp effective height >9 mm, aortic annulus <25 mm and the mean transaortic gradient <10 mm Hg should be met to satisfy the adequacy of repair.[13,14] Polain et al. found the inter-cusp coaptation length >4 mm as the single most important factor against the recurrence of moderate/severe aortic regurgitation while coaptation length <4 mm or below the aortic annulus was associated with the recurrence of aortic regurgitation.[15] Cusp effective height <9 mm have been found to be associated with 50% probability of reoperation within a ten year.[16] Our patient had mild residual aortic regurgitation with inter-cusp coaptation length 7 mm and cusp effective height 13 mm. The mean aortic valve gradient measured was 9 mm Hg, suggesting adequate repair.

CONCLUSION

The aortic valve injury during percutaneous catheterization is a potential catastrophic complication that may remain unnoticed and present as chronic aortic regurgitation. Intraoperative transesophageal echocardiography may be instrumental in its detection and aid in the assessment of the adequacy of the valve repair during the surgical repair of the injured valve.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

Videos Available on: www.annals.in

Download video file (156.9KB, mp4)
Download video file (99.1KB, mp4)

REFERENCES

  • 1.Madigan M, McIsaac S, Garg A, Alqahtani A, Kumar A, Atoui R. Rare case of iatrogenic aortic valve leaflet tear following a diagnostic coronary angiogram. J Card Surg. 2020;35:204–6. doi: 10.1111/jocs.14272. [DOI] [PubMed] [Google Scholar]
  • 2.Denyer MH, Elliott CM, Robicsek F. Pericardial patch repair of aortic cusp perforation caused by cardiac catheterization. J Card Surg. 1988;3:155–57. doi: 10.1111/j.1540-8191.1988.tb00233.x. [DOI] [PubMed] [Google Scholar]
  • 3.Kotoulas C, Bigeon JY, Patris K, Hasan R. Aortic valve as a victim of percutaneous coronary angioplasty and stenting. Ann Thorac Surg. 2007;84:1765. doi: 10.1016/j.athoracsur.2006.12.054. [DOI] [PubMed] [Google Scholar]
  • 4.Bouabdallaoui N, Banfi C, Neicu DV, Juthier F, Ennezat PV. Repair of iatrogenic aortic regurgitation following cardiac catheterization. J Card Surg. 2011;26:485–87. doi: 10.1111/j.1540-8191.2011.01306.x. [DOI] [PubMed] [Google Scholar]
  • 5.Ong G, Bagur R, Barbeau G, Couture C, Trahan S, Déry J-P. Severe aortic regurgitation after transradial percutaneous coronary intervention. Circ Cardiovasc Interv. 2011;4:e8–11. doi: 10.1161/CIRCINTERVENTIONS.110.960369. [DOI] [PubMed] [Google Scholar]
  • 6.Gamaza Chulián S, Camacho Freire SJ, León Jiménez J, Luna AA, Martínez TD, Otero MJO. Percutaneous coronary intervention: A rare cause of acute traumatic aortic regurgitation. Rev Esp Cardiol (Engl Ed) 2017;70:501–2. doi: 10.1016/j.rec.2016.09.017. [DOI] [PubMed] [Google Scholar]
  • 7.Rolf T, Tozzi P, Roumy A, Iglesias JF, von Segesser LK. Aortic valve lesion after coronary angiography. Interact Cardiovasc Thorac Surg. 2011;12:205–6. doi: 10.1510/icvts.2010.252155. [DOI] [PubMed] [Google Scholar]
  • 8.Safar B, Milleron O, Mesnildrey P, Cattan S. Aortic regurgitation after cardiac catheterization. JACC Cardiovasc Interv. 2010;3:984–5. doi: 10.1016/j.jcin.2010.04.018. [DOI] [PubMed] [Google Scholar]
  • 9.Aziz F, Baciewicz FA., Jr Lambl’s excrescences: Review and recommendations. Tex Heart Inst J. 2007;3:366–68. [PMC free article] [PubMed] [Google Scholar]
  • 10.Klarich KW, Enriquez-Sarano M, Gura GM, Edwards WD, Tajik AJ, Seward JB. Papillary fibroelastoma: Echocardiographic characteristics for diagnosis and pathologic correlation. J Am Coll Cardiol. 1997;30:784–90. doi: 10.1016/s0735-1097(97)00211-8. [DOI] [PubMed] [Google Scholar]
  • 11.Odim J, Laks H, Allada V, Child J, Wilson S, Gjertson D. Results of aortic valve-sparing and restoration with autologous pericardial leaflet extensions in congenital heart disease. Ann Thorac Surg. 2005;80:647–53. doi: 10.1016/j.athoracsur.2005.03.060. [DOI] [PubMed] [Google Scholar]
  • 12.Tao L, Zeng XJ, Lim YP. Single cusp replacement for aortic regurgitation. Ann Thorac Surg. 2008;85:946–48. doi: 10.1016/j.athoracsur.2007.10.037. [DOI] [PubMed] [Google Scholar]
  • 13.Berrebi A, Monin JL, Lansac E. Systematic echocardiographic assessment of aortic regurgitation- What should the surgeon know for aortic valve repair? Ann Cardiothorac Surg. 2019;8:331–41. doi: 10.21037/acs.2019.05.15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Pushpa J, Ananda Bhat, Parimala Prasanna Simha, Prasanna Simha M, Manjunatha N. Perioperative echocardiography in Ozaki’s procedure: An observational study-Single centre experience. MedPulse International Journal of Anesthesiology. September. 2019;11:268–73. [Google Scholar]
  • 15.Le Polain de Waroux JB, Pouleur AC, Robert A, Pasquet A, Gerber BL, Noirhomme P, et al. Mechanisms of recurrent aortic regurgitation after aortic valve repair: Predictive value of intraoperative transesophageal echocardiography. JACC Cardiovasc Imaging. 2009;2:931–9. doi: 10.1016/j.jcmg.2009.04.013. [DOI] [PubMed] [Google Scholar]
  • 16.Aicher D, Kunihara T, Abou Issa O, Brittner B, Gräber S, Schäfers HJ. Valve configuration determines long-term results after repair of the bicuspid aortic valve. Circulation. 2011;123:178–85. doi: 10.1161/CIRCULATIONAHA.109.934679. [DOI] [PubMed] [Google Scholar]