Skip to main content
Australasian Journal of Ultrasound in Medicine logoLink to Australasian Journal of Ultrasound in Medicine
. 2020 Aug 3;23(3):194–206. doi: 10.1002/ajum.12219

Ultrasound parameters to identify and diagnose carpal tunnel syndrome. A review of the literature

Callum Linehan 1,✉, Jessie Childs 2, Ann E Quinton 3,4, Aamer Aziz 5
PMCID: PMC8411739  PMID: 34760599

Abstract

Numerous works of literature have assessed the use of ultrasound to detect carpal tunnel syndrome, suggesting various techniques and cut‐off values. Currently, an effective parameter and cut‐off value are still debated. The aim of this review is to determine if these parameters have sufficient rigour to allow their use in clinical practice. Twenty‐one studies using sonographic parameters to identify carpal tunnel syndrome in comparison with electrodiagnostic testing (EDx) were selected for review. Methodological differences were found between studies in the use of EDx criteria, scanning and recruitment protocols, with participant biometrics often not reported. Parameters including the cross‐sectional area of the median nerve at the level of the pisiform bone in addition to the wrist‐to‐forearm difference demonstrated high diagnostic utility for set cut‐off values. Doppler techniques and mobility are promising, and further research is required to understand the effectiveness of these techniques.

Keywords: carpal tunnel syndrome, cross‐sectional area, electrodiagnostic, electrophysiologic, ultrasound

Introduction

Carpal tunnel syndrome (CTS) defines the symptomatic compression of the median nerve at the carpal tunnel.1 The condition accounts for 90% of peripheral entrapment neuropathies affecting up to 5% of the population.2, 3 Affected individuals experience paraesthesia and motor sensory loss in the distribution of the median nerve with thenar muscle atrophy, risking increasing morbidity without timely diagnosis.3, 4, 5 Currently, a strong consensus exists for clinical diagnosis based on the patient history and physical examination in conjunction with electrodiagnostic testing (EDx).6, 7, 8, 9, 10

Electrodiagnostic testing is considered by authors to be an accurate test, with a sensitivity and specificity of 78–95% and 80–95%, respectively.1, 11, 12, 13, 14 However, other authors have reported varying false‐negative rates of 10–34%.2, 6, 7, 8, 9 The test assesses for physiological delays within the median nerve through slowed electrical conduction due to compression, representing the degree of inflammation and axon loss.10, 11, 15 This enables the detection of CTS with grading of the severity.11, 14 However, EDx requires an invasive approach and an extended examination time, with limited and often cost‐prohibitive availability.2, 5, 7 Additionally, EDx lacks the ability to diagnose underlying anatomical causes of compressive neuropathy.15, 16, 17 As such, with lack of a universal gold standard test, a growing trend is seen for additional diagnostic methods in medical imaging such as ultrasound.6, 9

The use of ultrasound in the diagnosis of CTS has increased over the last two decades, owing to its accessible, inexpensive and non‐invasive nature.1, 3, 4, 5 The high‐resolution real‐time imaging capabilities demonstrate altered median nerve characteristics along with anomalous muscles, ganglions, and tendon pathology.5, 9, 16, 18 Multiple works have investigated differing techniques for quantifying the degree of neural thickening in affected wrists. Examples include the inlet and outlet cross‐sectional area, inlet‐outlet ratio, wrist‐to‐forearm ratio, and the cross‐sectional area difference between the wrist and forearm.1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 In addition, a flattening ratio and supplementary parameters of colour Doppler and median nerve mobility are also reported in the literature.2, 4, 6, 7, 11, 20

Many studies have compared these ultrasound parameters using differing study designs with varying results.1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 Factors that account for variability between studies include participant characteristics (e.g. race, age, gender, height, weight, and body mass index) and anthropometrics (e.g. wrist circumference).15, 18, 19 The variations in sample size, with differing inclusion and exclusion criteria of case/control groups, combined with no established gold standard for diagnosis of CTS, cause further variation between studies.6, 9 The non‐standardisation of measuring protocols and equipment differences leads to further variability.18, 19 Furthermore, interrater reliability, operator experience, and blinding are often unaccounted for, potentially reducing the impact of results.6, 10, 17 Consequently, meaningful analysis of the literature is challenging due to differences between study designs, thus increasing the difficulty of determining the diagnostic utility of ultrasound in CTS.2, 14 While not a perfect test, the use of EDx may provide a basis for comparison for the diagnostic utility of ultrasound in CTS.

The aim of this review is to identify the sonographic parameters used to diagnose CTS in comparison with EDx and determine if these sonographic parameters have sufficient rigour to allow their use in clinical practice. Previously published articles will be examined for participant numbers, demographics and biometrics, reference standards, inclusion and exclusion criteria, equipment, scanning protocol and reliability in addition to the sensitivity and specificity of each parameter.

Methodology

Search Strategy

Online databases were accessed through an institution. PubMed, MEDLINE, Springer, and Science Direct were searched using a Boolean search strategy utilising the operators ‘AND’, ‘OR’, and ‘NOT’, in conjunction with the keywords ‘carpal tunnel syndrome’, ‘ultrasound’, ‘ultrasonography’, ‘sonography’ in titles; and ‘electrodiagnostic’, ‘electrophysiologic’, and ‘cross‐sectional area’. Figure 1 demonstrates the selection process of retrieved articles. For articles to be considered for inclusion, abstracts needed to contain at least one of the additional keywords: wrist‐to‐forearm ratio, wrist‐to‐forearm difference, inlet, outlet, flattening ratio, colour or power Doppler, dynamic, mobility, transverse displacement, sensitivity, or specificity.

Figure 1.

Figure 1

Study selection flow chart.

Inclusion criteria

For inclusion, articles were required to be prospective, have measured either the cross‐sectional area at the carpal tunnel inlet or outlet, wrist‐to‐forearm ratio, wrist‐to‐forearm difference, flattening ratio, or other complimentary findings including colour Doppler and nerve mobility. The sensitivity and specificity of the above parameters needed to be specified, utilising EDx as the reference standard. A research design of a significant sample size (>30 participants) with clearly specified exclusion criteria and having been published in English between 2008 and 2018 were also required.

Exclusion criteria

Exclusion criteria were using clinical diagnosis or other methods as a reference standard.

Results

The 21 articles included in the review utilised either a case‐control or observational design to assess the sonographic parameters. The main characteristics of these studies are summarised in Tables 1, 2, 3.

Table 1.

Control testing and demographic data of case and control groups.

Authors Total participants (n)

Case group male/female (n)

mean age (SD)

Control group male/female (n)

mean age (SD)

Case group height cm (SD) weight kg (SD) BMI (SD)

Control group height cm (SD)

weight kg (SD)

BMI (SD)

Control testing
Mohamed et al. (2018)1 75

14/36

53.3 (8.4)

9/16

51.6 (8.8)

Not stated Not stated EDx
Kuo et al. (2016)2 72 Not stated Not stated Not stated Not stated EDx
Azami et al. (2014)3 180

5/55

56.8 (10.6)

2/28

54.8 (7.8)

162.5 (5.8)

77.8 (4.7)

29.5 (2.4)*

162.9 (4.9)

71.2 (4.9)

26.8 (4.9)

Clinical
Maha et al. (2012)4 41

10/31

47 (5.62)/49.1 (6.5)

No control Not stated No control No Control
Ackar et al. (2010)5 42

16/26

45.7 (9.7)

11/22

42 (12)

Not stated Not stated Clinical
Ooi et al. (2014)6 66

9/42

55

3/12

53

Not stated Not stated Clinical
Ng et al. (2018)7 41

4/20

57 (5.4)

4/13

55.5 (8.7)

Not stated Not stated Clinical
Kim et al. (2014)8 154

30/216

53

3/27

41.7

Not stated Not stated Clinical
Borire et al. (2016)9 121

Not stated

55.0 (11.8)

Not stated

51.1 (8.2)

165.9 (9.08)

83.7 (21)

30.4 (7.5)

173 (10.3)

87.3 (16.2)

29.0 (5.0)

Not stated
Mhoon et al. (2012)10 125

42/58

55 (12.3)

11/14

45 (13.2)

167.6 (11.2)

90.1 (23.1)

(Not stated)

168.4 (9.9)

80.8 (20.5)

(Not stated)

EDx
Kutlar et al. (2017)11 121

12/59

48.6 (10.9)

10/40

48.3 (9.2)

Not stated Not stated Clinical
Kang et al. (2011)12 140

10/100

53.18

2/36

53.18 (6.20)

Not stated Not stated Not stated
Hobson‐Web et al. (2008)13 62

10/44

52.4 (12.8)

10/18

39.2 (14.2)

165.6 (9.4)

Not stated

Not stated

173.7 (10.4)*

Not stated

Not stated

Clinical
Azman et al. (2017)14 136

28/58

53.8 (12.3)

18/32

53.8 (14.4)

Not stated

Not stated

29.4 (5.17)

Not stated

Not stated

26.8 (4.12)

EDx
Hunderfund et al. (2011)15 104

23/32

59 (15)

23/26

6 (16)

166.6 (9.8)

86.4 (20.8)

30.9 (5.9)*

169.7 (11.2)

80.1 (21.9)

27.4 (5.5)

EDx
Ulasli et al. (2012)16 82

4/51

47.3 (11.9)

4/23

40.5 (9.6)

162 (5)

79.5 (12.5)

36.6 (5.93)*

162 (6)

70.6 (10)

32.3 (5.25)

EDx
Fu et al. (2015)17 90

16/30

45.3 (19.8)

18/26

50.4 (13.9)

163 (8)

58.2 (11.5)

21.7 (3.33)

165 (7)

57.8 (11.3)

21.1 (2.7)

EDx
Klauser et al. (2009)18 126

16/52

(57.9)

16/42

(55.1)

Not stated Not stated Clinical
Roll et al. (2011)19 91

10/37

45.6 (10.6)

14/30

40 (12.1)

166 (8.3)

88 (21.2)

32 (7.4)

168.8 (8.5)

78 (19.7)

27.4 (7)

Clinical
Ghasemi‐Esfe et al. (2011)20 156

23/78

50.9 (1.29)

14/41

48.51 (1.7)

No stated Not stated EDx
Dejaco et al. (2013)21 135

36/99

51.0 (14.5)

5/18

50.4 (6.7)

Not stated

Not Stated

26.8 (4.3)

Not stated

Not stated

Not stated

Clinical

BMI, Body Mass Index; cm, centimeters; EDx, electrodiagnostic testing; kg, kilograms; n, number; SD, standard deviation.

Significant difference.

Table 2.

Cut‐off values for electrodiagnostic testing and operator variables.

Authors Electrodiagnostic value for recruitment of CTS cases Ultrasound machine/Tx frequency Measuring technique Operator/experience Interrater reliability/blinding
Mohamed et al. (2018)1 Not stated Medison Accuvix IX, Seoul, Korea/12 MHz Continuous trace Radiologist/>12 years Not stated
Kuo et al. (2016)2

SVC < 40 m/s

DSL > 2.5 ms

DML > 4.0 ms

Model t3000, Terason, MA/10 MHz Transverse displacement Musculoskeletal physician/>10 years Not stated
Azami et al. (2014)3

SNCV < 40 m/s

DML > 4.5 ms

A MEDISON V20 ultrasound machine/14 MHz Not stated Radiologist/not stated Not stated/Blinded
Maha et al. (2012)4

DSL > 2.9 ms

DML > 4.2 ms

Philips HD 10/12 MHz Ellipse method Radiologist/>5 years Not stated
Ackar et al. (2010)5

SNCV < 50 m/s

DML > 4 ms

MUDS 0.4 ms

Toshiba SSA 770 A/7.5 MHz Continuous trace Radiologist/12 years Not stated
Ooi et al. (2014)6 Not stated Philips iU22 machine/17–5 MHz Continuous trace 2 Sonographers/>5 years k = 0.71–0.89 (CSA)/Blinded
Ng et al. (2018).7

DML > 4 ms

MUDS > 0.4 ms

Philips iU22 machine/12–17 MHz Continuous trace Radiologist/>15 years Not stated/Not blinded
Kim et al. (2014).8 Not stated Sonix RP/not specified Continuous trace Not stated Not stated
Borire et al. (2016).9

CMAP (Value not specified)

DML (value not specified)

SNAP (Value not specified)

MyLabOne system/10 –18 MHz Continuous trace Not stated Not stated
Mhoon et al. (2012).10

DML> 4.3 ms

MUDS> 0.4 ms

Median mixed nerve latency > 2.2 ms

Biosound Esaote MyLab 70/18‐MHz Continuous trace Neurologist/Not stated r = 0.9845/0.9641 (CSA/WFR)/Blinded
Kutlar et al. (2017).11

DML (value not specified)

SNAPs (value not specified)

MUDS ≥ 0.5 ms

Aplio 500 A/7–14 MHz Continuous trace Radiologist/>10 years Not stated/Blinded
Kang et al. (2011).12

DML latency > 4.2 ms

CMAP amplitude: 4.1–4.5 mV

SNAP amplitude: 16–20 μV

M2540A Envisor Ultrasound Imaging System/not specified Continuous trace Not stated Not stated
Hobson‐Web et al. (2008)13

DML ≥ 4.4 ms

Median mixed nerve latency ≥ 2.2

Phillips HDI 5000/15–7 MHz Continuous trace Sonographer/Not stated Not stated/Blinded
Azman et al. (2017)14

DML ≥ 4.3 ms

MUDS ≥ 0.4 ms

ProSound a7 Premium US system/5–13 Mhz Continuous trace and ellipse Sonographer/Not stated Not stated/Blinded
Hunderfund et al. (2011)15

DML (value not specified)

SNAP (Absence)

CMAP (value not specified)

GE logiq e device/5–13 MHz Continuous trace Imaging by sonographers, measurements by unspecified investigator

Not stated/unblinded

Imaging, blinded measurement

Ulasli et al. (2012)16

NCVs (values not specified)

SNAP (values not specified)

CMAP (Values not specified)

GE Healthcare Logiq S6/10–14 MHz Continuous trace Radiologist and physiatrist/not stated Not stated
Fu et al. (2015)17

MUDS > 0.4 ms

DML > 4.0 ms

Aplio 500 Ultrasound System/5–13 MHz Continuous trace Radiologist/>10 years

k = 0.79/0.88

(inlet/outlet CSA)/blinded

Klauser et al. (2009)18 Padua et al. scoring system (values not specified) Mylab90/14–8 MHz Continuous trace Radiologist/>5 years Not stated/blinded
Roll et al. (2011)19

SNCV < 50 m/s

SNAP < 10 μV

DML > 4.2 ms

CMAP < 4.0 mV

GE Healthcare LOGIQ i ultrasound system/12 MHz Continuous trace Sonographer/not stated Value not stated/Blinded to EDx
Ghasemi‐Esfe et al. (2011)20

Prolonged median sensory latency 3.5 ms

DML > 4.2 ms

Siemens Sonoline Antares/9–13 MHz Continuous trace Radiologist/>5 years Value not stated/Blinded
Dejaco et al. (2013)21

DML 4.2 ms

CMAP 5 mV

GE Logiq E9 ultrasound device/6–15 MHz Continuous trace 2 Rheumatologist/>5 years Not stated/Blinded

CMAP, Compound muscle action potential; CTS, Carpel Tunnel Syndrome; DML, Distal Motor Latency; DSL, Distal Sensory Latency; k, Kappa score; m/s, meters per second; MHz, Megahertz; ms, millisecond; MUDS, Median‐Ulnar Differences for Sensory Latencies; mV, millivolt; NCV, Nerve Conduction Velocity; r, Pearson's Correlation Coefficient; SNAP, Sensory Nerve Action Potential; SNCV, Sensory Nerve Conduction Velocity; Tx, transducer; μV, microvolt.

Table 3.

Sensitivity and specificity of diagnostic values for sonographic parameters.

Authors Parameter Cut‐off value Sensitivity Specificity Case wrists (n) Control wrists (n)
Mohamed et al. (2018)1

CSA inlet (pisiform)

Outlet (hamate)

9 mm2

9 mm2

95%

96%

100%

100%

50 25
Kuo et al. (2016)2 Mobility (transverse displacement) – 85% 96.9% 40 32
Azami et al. (2014)3

CSA inlet (proximal edge retinaculum)

CSA outlet (distal edge retinaculum)

FR (outlet)

9.15 mm2

8.15 mm2

0.93

99.2%

96.7%

99.2%

88.3%

55%

75%

120 60
Maha et al. (2012)4

CSA inlet (not defined)

Vascularity

11 mm2

Power Doppler

94%

98%

40%

60%

53 0
Ackar et al. (2010)5

CSA inlet (pisiform)

WFD (pisiform/hamate)

FR (outlet‐hamate)

11 mm2

3.65 mm2

2.57

76%

83%

66%

77%

82%

64%

62 33
Ooi et al. (2014)6

CSA inlet (pisiform)

CSA Outlet (Hamate)

FR (outlet hamate)

Mobility

Vascularity

9.8 mm2

10 mm2

3.4

Transverse displacement

Colour Doppler

92%

65%

65%

58%

69%

90%

85%

60%

86%

95%

95 30
Ng et al. (2018)7

CSA Inlet (not defined)

CSA Outlet (not defined)

FR (inlet – pisiform)

Vascularity

14 mm2

14 mm2

2.51

Colour Doppler

75%

63.6

68%

38.1%

87.5%

100%

45%

87.5

44 32
Kim et al. (2014)8

CSA Inlet (pisiform)

FR (inlet – pisiform)

10 mm2

3.4

88.5%

77.8%

90%

50%

246 30
Borire et al. (2016)9

CSA inlet (pisiform)

WFR (pisiform/mid‐forearm)

11.4 mm2

1.53

71%

60%

97.5%

92.5%

131 40
Mhoon et al. (2012)10

CSA Inlet (distal wrist crease)

WFR (distal wrist crease/mid‐forearm)

9 mm2

>1.4

99%

97%

22%

29%

192 50
Kutlar et al. (2017)11

CSA Inlet (pisiform)

Vascularity

10 mm2

Power Doppler

90.9%

93.4%

94%

90%

121 50
Kang et al. (2011)12

CSA Inlet (distal wrist crease)

WFR (distal wrist crease/forearm 12 cm proximal to wrist crease)

9.5 mm2

1.34

96.4%

99.9%

92.1%

100%

110 38
Hobson‐Web (2008)13 WFR (pisiform/forearm 12 cm proximal to wrist crease) >1.4 100% Not stated Not stated Not stated
Azman et al. (2017)14

CSA Inlet (pisiform)

CSA outlet (hamate)

WFR (not specified)

IOR

10 mm2

11 mm2

1.7

–

94.6%

74.1%

77.8%

–

82.9%

92.5%

91.4%

–

135 93
Hunderfund et al. (2011)15

CSA Inlet (proximal edge retinaculum)

WFR (pisiform/mid‐forearm)

WFD (pisiform/mid‐forearm)

11 mm2

≥2.4

>6 mm2

84%

67%

82%

84%

86%

84%

Not stated Not stated
Ulasli et al. (2012)16

CSA Inlet (proximal edge retinaculum)

CSA Oulet (hamate)

WFR (proximal edge retinaculum/forearm 12 cm proximal to wrist crease)

9.5 mm2

9.5 mm2

1.93

95%

86%

95%

71%

88%

98%

95 48
Fu et al. (2015)17 IOR 1.3 91% 93% 46 44
Klauser et al. (2009)18

CSA (proximal to distal tunnel)

WFD (Wrist/forearm level of pronator quadratus)

12 mm2

2 mm2

94%

96%

95%

100%

100 93
Roll et al. (2011)19

CSA Inlet (pisiform)

WFR (pisiform/distal radius)

WFD (pisiform/distal radius)

10.3 mm2

1.7

4.16 mm2

80.4%

80.4%

82.4%

90.6%

81.2%

87.5%

83 83
Ghasemi‐Esfe et al. (2011)20

Vascularity

CSA Inlet (pisiform)

Colour/power

Doppler

10.5 mm2

83%

71%

89%

91%

101 Not stated
Dejaco et al. (2013)21

CSA Inlet (proximal edge retinaculum)

CSA largest (Inlet to outlet)

WFR (wrist/proximal third of pronator quadratus)

WFD (CSA largest to proximal third of pronator quadratus)

Vascularity

9.8 mm2

9.8 mm2

1.3

2.5 mm2

Power Doppler

90.9%

91.8%

90.9%

93.6%

47.4%

61.2%

60%

50.6%

55.3%

89.8%

111 40

CSA, Cross‐sectional area; FR, Flattening ratio; IOR, Inlet‐to‐outlet ratio; mm, millimetre; n, number; WFD, Wrist‐to‐forearm difference; WFR, Wrist‐to‐forearm ratio.

Participant variables of the study design

Table 1 demonstrates all studies recruited participants over 18 years of age.1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 Each study had a sample volume ranging from 41 to 180 total participants.3, 4 Case groups were composed of volunteers with clinical signs of CTS and positive EDx. In 10 studies, the control groups were asymptomatic volunteers screened through questioning of clinical backgrounds.3, 5, 6, 7, 8, 11, 13, 18, 19, 21 In addition, eight studies assessed the control groups with EDx,1, 2, 10, 14, 15, 16, 17, 20 two studies did not state the recruitment methods of controls,9, 12 and one study had no control group.4

Many studies used bilateral observations of single participants, treating each wrist individually in the statistical analysis.3, 5, 10, 12, 13, 14, 16, 17, 18, 19 The participant characteristics (age, height, weight, body mass index, and gender ratio) of all 21 studies are summarised in Table 1. Many studies specified the mean age and male‐to‐female ratio of both case and control groups, with matching of case/controls in 13 studies.1, 3, 5, 6, 7, 9, 11, 12, 14, 15, 18, 20, 21 Moreover, the height, weight, and BMI of case/control participants were recorded in six studies3, 9, 15, 16, 17, 19 with three studies only measuring the height,13 BMI,14 and both weight and height.10 Fu et al.17 had matched case and control groups stating no significant differences. Conversely, BMI was increased in case groups across many studies.3, 14, 15, 16, 19 Increasing BMI had significant correlations with increased wrist CSA measurements in two studies.17, 19 Weight was increased in four case groups3, 10, 17, 19 and had significant correlations with increasing neural thickness at the forearm16 and wrist.17 Additionally, two studies found that increased height correlated with a larger CSA within the forearm in control groups.13, 16 However, one study had found no significant correlation between height, weight, BMI, and the median nerve thickness.15

Technical factors of the study design

Summarised in Table 2, EDx criteria for recruitment of participants differed between many studies using differing techniques and cut‐off values for diagnosing CTS. The electrodiagnostic values used for inclusion of case groups were stated by 11 studies.3, 4, 5, 7, 10, 12, 13, 14, 17, 19, 20 Six studies did not specify the diagnostic values of these techniques,9, 11, 15, 16, 18, 21 and four studies had not specified any information regarding the techniques and diagnostic values used.1, 2, 6, 8

The exclusion criteria for case and control groups varied between studies. Thirteen studies clearly specified the exclusion of systemic disorders including either diabetes,1, 2, 4, 5, 6, 8, 10, 12, 15, 16, 18, 20 hypothyroidism,2, 4, 5, 6, 8, 16, 18, 20 chronic renal failure,1, 2, 4, 5, 6, 18, 20 or rheumatoid arthritis1, 2, 4, 5, 7, 8, 16 in addition to other factors of traumatic injury1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 16, 17, 19, 20 and previous wrist surgery.3, 4, 5, 6, 9, 11, 13, 14, 15, 16, 17, 19, 21 Furthermore, cervical radiculopathy and polyneuropathy were clearly excluded by 10 studies.2, 3, 4, 6, 12, 14, 16, 17, 20, 21 Contrary to this, many studies did not specify the inclusion or exclusion of systemic diseases3, 7, 9, 13, 14, 17 or pregnancy1, 2, 5, 7, 8, 9, 11, 12, 18 while three studies included participants with either diabetes or thyroid disease.10, 19, 21 Anatomical variations including bifid median nerves were excluded by 10 studies to further standardise participants.1, 4, 5, 6, 11, 14, 16, 17, 19, 20 Additionally, four studies had included these variations for more variability within participants.9, 10, 15, 21 However, seven studies did not state whether these anatomical variations were included or excluded.2, 3, 7, 8, 12, 13, 18 Persisting median arteries were included by three studies,9, 10, 19 and excluded by three others.6, 15, 20

Table 2 summarises the specified equipment and operator used in the assessment of the median nerve between studies. The transducer frequency varied across studies ranging from 7 MHz to 18 MHz. Many of the recently published articles used a higher resolution 14 or 18 MHz linear array transducer.3, 6, 7, 9, 10, 11, 16, 21 The median nerve cross‐sectional area was measured through continuous tracing of the inner hyperechoic margin in 18 studies.1, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18, 19, 20, 21 One study used an ellipse method calculated by the machine,4 with an additional study utilising both methods.14 In addition, the operator experience varied considerably between studies. In six studies, a radiologist with over 10 years’ experience conducted the ultrasound1, 2, 5, 7, 11, 17 and five years’ experience in three other studies.4, 18, 20 In the remaining studies, the ultrasound was performed by either a sonographer, neurologist, or rheumatologist with varying levels of experience.2, 6, 10, 13, 14, 15, 19 Operators were blinded to participant symptoms and EDx in 12 studies,3, 6, 10, 11, 13, 14, 15, 17, 18, 19, 20, 21 and while only a few studies assessed the interrater reliability of cross‐sectional area measurements, the results showed a good level of agreement (k = 0.71–0.89,6, 17 r = 0.96–0.98).10

Diagnostic value of parameters

The main parameters and associated diagnostic values from the 21 selected articles are summarised in Table 3. Overall, the sensitivity and specificity of ultrasound were good for most parameters. The inlet cross‐sectional area was the most commonly assessed parameter. The sensitivity and specificity ranged from 71 to 99% and from 22 to 100%. Ten studies stated the sensitivity and specificity to be greater than 80%, reaching up to 99% and 100%, respectively.1, 2, 3, 6, 8, 11, 12, 14, 15, 19 However, the associated optimal cut‐off values used to diagnose CTS differed between studies, ranging from 9 to 14 mm2. Additionally, the definition of the tunnel inlet varied across studies, with authors using the pisiform,1, 5, 6, 8, 9, 11, 14, 19, 20 proximal margin of the retinaculum,3, 15, 16, 21 and distal wrist crease10, 12 as landmarks. The tunnel outlet cross‐sectional area was investigated by six studies and commonly defined by the level of the hook of the hamate bone.1, 6, 14, 16 The outlet sensitivity and specificity ranged from 64 to 97% and from 55 to 100%, respectively. Three studies found a sensitivity of >86%1, 3, 16 with five studies determining a specificity of >85%.1, 6, 7, 14, 16 However, cut‐off values varied from 8.1 to 14 mm2.1, 3, 6, 7, 14, 16

Many studies assessed the application of measuring the CSA at two locations using the wrist inlet, outlet or forearm. The wrist‐to‐forearm ratio sensitivity and specificity ranged from 60 to 100% and from 29 to 100%, respectively. The optimal cut‐off ratios ranged from 1.3 to 1.9 in eight studies9, 10, 12, 13, 14, 16, 19, 21 and 2.4 by an additional study.15 Ratios were calculated by using the CSA at the inlet and forearm. Described locations of forearm measurements differed between studies; involving the mid‐forearm,9, 10, 15 12 cm proximal to the wrist crease,12, 13, 16 level of the pronator quadratus muscle,21 distal forearm,14 and distal radius.19 Additionally, the wrist‐to‐forearm difference was subject to similar variations with the sensitivity and specificity of the difference ranging from 82 to 96% and from 55 to 100% and optimal cut‐off values of 2–6 mm2 reported.15, 18, 19, 21 In addition, the inlet‐outlet ratio described by Fu et al.17 was reported to be 91% sensitive and 93% specific with a ratio of 1.3. However, Azman et al.14 had excluded this parameter from further analysis due to insignificant differences between case and control groups.14

Seven studies had assessed the flattening ratio, using differing locations at the wrist including the level of the hook of hamate,5, 6 pisiform,7, 8, 19 distal flexor retinaculum,3 and mid‐carpal tunnel.14 The sensitivity and specificity ranged from 65 to 78% and from 45 to 75%, with optimal cut‐off values ranging from 2.5 to 3.4.5, 6, 7, 8 One study had reported a sensitivity and specificity of 92% and 75% at a cut‐off of 0.93.3 However, two studies had excluded this parameter from further assessment due to insignificant values between cases and controls.14, 19

The vascularity of the median nerve was assessed by six studies, using either colour6, 7, 20 or power Doppler.4, 11, 20, 21 The sensitivity and specificity varied between studies ranging from 38 to 98% and from 60 to 95%, respectively. In addition, the mobility of the median nerve defined by degree of the transverse displacement in two studies during flexion/extension of the fingers had a sensitivity and specificity of 69–85% and 95–97%, respectively.2, 6

Discussion

For the diagnosis of CTS, the CSA of the median nerve at the level of the pisiform bone in addition to the wrist‐to‐forearm difference demonstrated good diagnostic utility for set cut‐off values of 10 mm2 and >2 mm2, respectively.6, 8, 11, 14, 15, 18, 19, 20, 21 In addition, a wrist‐to‐forearm ratio of 1.3 and 1.4 demonstrated a high sensitivity.10, 12, 13, 21 The use of ultrasound for diagnosing CTS is progressively increasing. Over the last two decades, many studies have assessed the diagnostic utility of ultrasound for detecting CTS. However, derived optimal cut‐off values in addition to the sensitivity and specificity vary significantly for each ultrasound parameter. The results of this literature review outline significant differences in study designs that account for variability between published articles. Consequently, the diagnostic values suggested by these articles are confounded by a lack of standardisation. This emphasises the need to improve the rigour of study designs to identify effective sonographic parameters for detecting CTS.

Study design limitations

Studies included in the review differed significantly through reference standards and scanning protocols. Currently, there is no established gold standard for diagnosing CTS.9, 10, 11 Electrodiagnostic testing is considered a credible reference standard due to the reasonable sensitivity and specificity in addition to the capabilities of grading the severity of CTS.2, 7, 11, 14 Conversely, false‐negative rates of EDx have been reported ranging from 10 to 34%.2, 6, 7, 8, 9, 20 This may impact the allocation of both case and control groups. Participants with mild symptomatic CTS may potentially be misdiagnosed with EDx as a false negative, as neural damage may not have occurred in the early stages.9 In addition, as outlined in Table 2, although many studies had specified the diagnostic values of EDx used to recruit CTS cases, these values varied, especially the distal median nerve latency (DML) ranging from >4 to >4.5 ms.3, 4, 5 This was also apparent for the sensory nerve conduction velocity (SNCV) and median to ulnar nerve difference (MUDS).3, 5, 11, 17 These differences in criteria may lead to misrepresentation through the inclusion and exclusion of affected participants in both case and control groups. Furthermore, many authors did not assess control groups using EDx.3, 5, 6, 7, 8, 11, 13, 18, 19, 21 This reduces rigour, as case/control group selection criteria differed through the reference standard.9, 15 One study by Azman et al.14 had excluded a control volunteer who tested positive in the electrodiagnostic test. By testing control groups, participants are more standardised through the selection process.15

The scanning technique varied between studies, utilising different methods of calculating the cross‐sectional area. Most authors used direct tracing of the inner hyperechoic border of the median nerve.1, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 This method is suggested to be superior to linear measures as the median nerve may become displaced by the adjacent tissues resulting in an irregular shape.19, 21 In contrast, one study used an ellipse formula to calculate the cross‐sectional area, potentially limiting the diagnostic accuracy of the measurements.4 Additionally, the variability of measurements was only accounted for by seven studies.6, 9, 11, 12, 19, 20, 21 These studies calculated a mean using two – three measurements to determine the cross‐sectional area, improving the diagnostic accuracy by accounting for operator related error.6, 9, 11, 12, 19, 20, 21 Furthermore, studies varied in the machines used (Table 2). However, probe frequencies were rather similar for many studies ranging from 12 to 18 MHz, with few studies using <10 MHz (Table 2). This indicates similarities of high‐resolution imaging between studies, resulting in improved diagnostic performance.

Summarised in Table 2, 12 studies accounted for blinding of the operator3, 6, 10, 11, 13, 14, 15, 17, 18, 19, 20, 21 with many studies not reporting1, 2, 4, 5, 8, 9, 12, 16 or attempting operator blinding.7 This poses limitations, as knowing participant symptoms and EDx values introduces potential bias into the results.7, 14, 15 Moreover, while many operators were experienced specialists with over five years’ experience in ultrasound, very limited data were available on interrater reliability.4, 7, 11 Consequently, this limits the diagnostic value of many studies and impacts the diagnostic value of the results.6, 7, 10, 17 The few studies that accounted for reliability found good agreement with correlation values ranging from 0.71 to 0.986, 7, 10, 17 An additional two studies had claimed good reliability in previous research but did not state the values.19, 20 Future research needs to focus on standardisation of study design, measurements and participant case and control enrolment characteristics and reporting reproducibility and reliability of the measures.

Variations in cut‐off values in addition to the range in sensitivity and specificity may relate to participant variables. In total, nine studies had measured a participant biometric (Table 1). The impact of these variables across these studies was varied. While BMI was increased in many case groups3, 14, 15, 16, 19 only two studies had stated a significant correlation with increased wrist CSA measurements.17, 19 Conversely, Roll et al.19 state that this relationship is not clear, as increased CSA measurements in participants with larger BMIs may be attributed to either a pathological result of increased BMI or increased anthropometric composition. Two studies described increased weight and height with larger forearm CSA measurements in control groups.13, 16 This may predispose variations of normal CSA measurements between studies.13, 16 Furthermore, one study described increased weight with larger inlet CSA measurements.17 However, one study stated no significant correlations between height, weight and BMI and the median nerve thickness.15 The significance of biometrics to potentially influence differing diagnostic cut‐off values remains varied and unclear, however, dual‐level parameters account for these variables.16, 19

The age and gender may increase risk of CTS.10, 16 Considering this, study designs that accounted for these variables through case/control matching may be of increased validity through comparable controls.19 In addition, the clinical background of participants is known to affect the median nerve.4 This is evident through hypothyroidism, diabetes, chronic renal failure, and rheumatoid arthritis.2, 3, 6, 10 Additionally, pregnancy and post‐surgical changes may lead to further variability between participants.7, 13, 15 This emphasises the need to implement clear and rigorous exclusion criteria for both case and control groups.1, 2, 3, 4, 6, 8, 12, 13, 14, 15, 16, 17, 19, 20, 21 By standardising the participants for analysis, the study design is strengthened. As disease status and pregnancy were not specified in the exclusion criteria of several studies, the reliability of the results may be reduced.1, 2, 3, 5, 7, 8, 9, 10, 11, 12, 13, 14, 17, 18

Four studies included participants with bifid median nerves in both case and control groups using the summated CSA of both branches.9, 10, 15, 21 Hunderfund et al.15 and Borire et al.9 tested for differences in results when excluding these variations from the analysis and found no statistical change. While many studies did not specify the inclusion or exclusion of this variation, results are likely to remain consistent.

Diagnostic utility of parameters

Single‐level cross‐sectional area measurements are the most widely assessed parameter. Nineteen studies summarised in Table 3 assessed the diagnostic utility with varying anatomical descriptions used to define the level of measurement locations. The pisiform bone was the most commonly used anatomical reference.1, 5, 6, 8, 9, 11, 14, 19, 20 Other authors considered the proximal margin of the retinaculum3, 15, 16, 21 and fewer authors specified the distal wrist crease for inlet measurements.10, 12 Cross‐sectional area measurements at the level of the pisiform appeared to consistently result in a cut‐off value of 10 mm2 with a high sensitivity and specificity range of 71–95% and 83–94%, respectively.6, 8, 11, 14, 19, 20 This may be due to ease of measuring at this level, using a bony landmark as the reference point. Contrary to this, the outlet was commonly defined by the level of the hamate bone in four out of six studies.1, 6, 14, 16 However, derived cut‐off values varied from 9 to 11 mm2 with a sensitivity and specificity ranging from 65 to 96% and from 85 to 100%, respectively. One author described a cut‐off value of 8.15 mm2 with a high sensitivity of 97% and low specificity of 55% at the distal margin of the flexor retinaculum.3 The variability may be attributed to the challenge of obtaining clear images at this region, as poor signal quality in addition to palm curvature and oblique coursing of the median nerve limits accurate measurements.1, 3, 6, 7, 14, 16 The distal tunnel is known for increased pressure and measuring at this location (distal margin of flexor retinaculum) may explain the smaller cut‐off value opposed to the level of the hamate bone.3 Variations in results may reflect the median nerve swelling occurring at differing locations in the wrist. Using the largest cross‐sectional area at the wrist, two studies found a sensitivity of 91–94% and specificity of 61–95%.18, 21 Specificity differences may be attributed to a smaller cut‐off value stated in Table 3. Furthermore, the singular measurement design is potentially vulnerable to differences in participant variables, as variations in normal nerve thickness secondary to demographics and biometrics may lead to false‐positive results.16, 19

Multilevel parameters address variations in participant demographics and biometrics. The wrist‐to‐forearm ratio and wrist‐to‐forearm difference account for these factors through incorporating a normal segment of the median nerve within the forearm as a comparison to the wrist.9, 10, 15 By using the participant as the control for testing, false‐positive rates in larger participants are potentially decreased.12, 19 Seven studies assessed the diagnostic utility with promising results.9, 10, 13, 14, 15, 19, 21 The sensitivity and specificity of the wrist‐to‐forearm ratio for cut‐off values of 1.3–2.4 ranged from 71 to 100% and from 29 to 100%, respectively.9, 10, 13, 14, 15, 19, 21 However, ratios of 1.3–1.4 were highly sensitive providing values from 91 to 100%.10, 12, 13, 21 The larger cut‐off values may be related to differences in measurement locations between authors.9, 13, 19 Moreover, differences between study designs may contribute to cut‐off variations through poor case/control matching and differences in scanning technique, measuring at differing locations.15 Future studies need to be designed to ensure predictive validity is optimised.

In addition, the wrist‐to‐forearm difference quantifies the differences of the cross‐sectional area between the wrist and forearm. This method consistently demonstrated high sensitivity and specificity in four studies ranging from 82 to 99% and from 82 to 100% for values of 2–6 mm2.5, 15, 18, 19 An additional study derived a lower specificity of 54%; however, differed in study design through exclusion of healthy controls in the ROC analysis.21 These studies were subject to similar limitations of the previous parameter through differing measurement locations. This was evident through the difference between the cut‐off values of Hunderfund et al.15 and Klauser et al.18 who found a difference of 6 and 2 mm2, respectively. Hunderfund et al.15 explained that the CSA at the distal forearm was often found to be thickened in CTS cases, while measurements in the mid‐forearm resulted in no significant differences between cases and controls. This may account for the smaller value of 2 mm2 by Klauser et al.18 as similarities in a thickened segment reduce the difference reported.

The flattening ratio quantifies the degree of neural compression at the carpal tunnel by measuring the width and height of the median nerve.5, 6, 7, 8 This parameter consistently resulted in lower sensitivity and specificity in six studies ranging from 65 to 78% and from 45 to 75%, respectively, for ratios of 2.5–3.4.5, 6, 7, 8 Additionally, two studies excluded the parameter from further analysis due to insignificant results between case and control groups.14, 19 One study reported a lower ratio of 0.93, resulting in 92% sensitivity.3 Such variations may be the product of a lack of standardised measuring protocols across the studies, with authors measuring at differing anatomical landmarks in the wrist. However, the diagnostic utility of this parameter was questioned by studies owing to the large variability in ratio cut‐offs and lower diagnostic values.14, 19

Intraneural vascularity as assessed by colour or power Doppler is a subjective parameter that has been shown to match the sensitivity and specificity of EDx.6, 20 The parameter correlates with the severity of CTS and the degree of neural thickening.6, 11 Additionally, the technique may detect participants in occult stages before thickening occurs.20 This is reflected by the sensitivity and specificity of four studies ranging from 69 to 98% and from 60 to 90%, respectively, using either colour6, 7, 20 or power Doppler4, 11, 20, 21 techniques. However, two studies found a low sensitivity of <47% with a high specificity of >88%.7, 21 These differences may be attributed to differing methods of quantifying the degree of vascularity varied between studies, as two studies used the presence of intraneural vascularity,4, 6 one study assigned a score of 0–3 based on the number of vessels seen21 and two studies used software programs. One quantified the number of coloured pixels20 and the other measured the largest area of colour filling.11 Furthermore, differences in participant severity, differing equipment (Table 2), and optimisation may also contribute to this.7

The mobility of the median nerve was assessed by two studies, correlating reduced transverse displacement with increased severity of CTS.2, 6 The sensitivity and specificity were 58–86% and 85–97%, respectively.2, 6 Kuo et al.2 assessed mobility using a quantitative speckle tracking algorithm, enabling displacement values to be quantified. Conversely, Ooi et al.6 determined the degree of displacement more subjectively through operator observation at the carpal tunnel using a transverse plane with flexion and extension of the fingers. This presents a limitation of the study design and may account for differences in sensitivity.2 Both studies found nerve mobility effective in CTS assessment.2, 6 The combination of these subjective parameters was found to increase the diagnostic utility of ultrasound.6 Future studies should incorporate nerve mobility and colour Doppler assessment for CTS.

Limitations and suggestions for future research

This review is predisposed to bias as sonographic parameters were subjectively assessed based on the study design and diagnostic values. Furthermore, the validity of the research methodology is decreased by using a basic protocol for the selection of studies without critical appraisal assessments.

Future prospective study designs should focus on implementing more standardised criteria for EDx. Additionally, standardisation of anatomical locations for sonographic data collection is essential to improve research consistency for future systematic reviews and meta‐analysis. Limited research has assessed the relationship between the cross‐sectional area and participant biometrics and further investigation to determine the impact on diagnostic cut‐off values would be beneficial. Comparisons of the cross‐sectional area at the wrist and forearm are potentially more diagnostic than single‐level parameters and should be a focus in future research. Studies assessing the use of intraneural vascularity and median nerve mobility are limited and their use should be further investigated, as these parameters may provide additional diagnostic value to cross‐sectional area measurements.

Conclusion

To date, an effective standardised sonographic protocol is yet to be established for the diagnosis of CTS. Many studies have published differing parameters with varying diagnostic values. Significant differences in study design have led to inconsistencies between studies, limiting the determination of effective sonographic parameters in previous research. From the studies evaluated; ultrasound holds significant diagnostic utility in the assessment of CTS. The cross‐sectional area at the pisiform, wrist‐to‐forearm ratio, and difference consistently demonstrated high diagnostic value. The assessment of nerve mobility and intraneural vascularity is likely to increase this further. Variations in cut‐off criteria exist between studies and may be attributed to measurements at differing anatomical locations and characteristics of selection criteria. New research should focus to minimise variations in study designs to enable more comparable results.

Authorship statement

The authors acknowledge that this article conforms with the journal’s authorship policy, and all authors agree with the content of the submitted manuscript.

Funding

No funding information is provided.

Conflicts of interest

None of the authors have any conflict of interest to disclose.

Author contributions

Callum Linehan: Methodology (equal); Writing‐original draft (lead). Jessie Childs: Methodology (supporting); Writing‐original draft (supporting); Writing‐review & editing (equal). Ann Quinton: Writing‐original draft (supporting); Writing‐review & editing (equal). Aamer Aziz: Methodology (supporting); Writing‐review & editing (supporting).

References

  • 1.Mourad MA, Kareemb HA. Idiopathic carpal tunnel syndrome (ICTS): Correlation between nerve conduction studies and dynamic wrist ultrasonography. Egypt J Rad Nucl Med 2018; 49: 1060–7. [Google Scholar]
  • 2.Kuo TT, Lee MR, Liao YY, Chen JP, Hsu YW, Yeh CK. Assessment of median nerve mobility by ultrasound dynamic imaging for diagnosing carpal tunnel syndrome. PLoS One 2016; 11: e0147051. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Azami A, Maleki N, Anari H, Iranparvar Alamdari M, Kalantarhormozi M, Tavosi Z. The diagnostic value of ultrasound compared with nerve conduction velocity in carpal tunnel syndrome. Int J Rheum Dis 2014; 17: 612–20. [DOI] [PubMed] [Google Scholar]
  • 4.Abdel‐Ghaffar MK, El‐sinnawy MA, Fawzy H, Ibrahim SE. Gray scale and colour Doppler sonography in the diagnosis of carpal tunnel syndrome. Egypt J Rad Nucl Med 2012; 43: 581–7. [Google Scholar]
  • 5.Akcar N, Özkan S, Mehmetoglu Ö, Calisir C, Adapinar B. Value of power Doppler and gray‐scale US in the diagnosis of carpal tunnel syndrome: contribution of cross‐sectional area just before the tunnel inlet as compared with the cross‐sectional area at the tunnel. Korean J Radiol 2010; 11: 632–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Ooi CC, Wong SK, Tan AB, Chin AY, Abu Bakar R, Goh SY, et al. Diagnostic criteria of carpal tunnel syndrome using high‐resolution ultrasonography: correlation with nerve conduction studies. Skeletal Radiol 2014; 43: 1387–94. [DOI] [PubMed] [Google Scholar]
  • 7.Ng AWH, Griffith JF, Lee RKL, Tse WL, Wong CWY, Ho PC. Ultrasound carpal tunnel syndrome: additional criteria for diagnosis. Clin Radiol 2018; 73: 214. [DOI] [PubMed] [Google Scholar]
  • 8.Kim MK, Jeon HJ, Park SH, Park DS, Nam HS. Value of ultrasonography in the diagnosis of carpal tunnel syndrome: correlation with electrophysiological abnormalities and clinical severity. J Korean Neurosurg Soc 2014; 55: 78–82. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Borire AA, Hughes AR, Lueck CJ, Colebatch JG, Krishnan AV. Sonographic differences in carpal tunnel syndrome with normal and abnormal nerve conduction studies. J Clin Neurosci; 34: 77–80. [DOI] [PubMed] [Google Scholar]
  • 10.Mhoon JT, Juel VC, Hobson‐Webb LD. Median nerve ultrasound as a screening tool in carpal tunnel syndrome: correlation of cross‐sectional area measures with electrodiagnostic abnormality. Muscle Nerve 2012; 46: 871–8. [DOI] [PubMed] [Google Scholar]
  • 11.Kutlar N, Bayrak AO, Bayrak İK, Canbaz S, Türker H. Diagnosing carpal tunnel syndrome with Doppler ultrasonography: a comparison of ultrasonographic measurements and electrophysiological severity. Neurol Res 2017; 39: 126–32. [DOI] [PubMed] [Google Scholar]
  • 12.Kang S, Kwon HK, Kim KH, Yun HS. Ultrasonography of median nerve and electrophysiologic severity in carpal tunnel syndrome. Ann Rehabil Med 2012; 36: 72–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Hobson‐Webb LD, Massey JM, Juel VC, Sanders DB. The ultrasonographic wrist‐to‐forearm median nerve area ratio in carpal tunnel syndrome. Clin Neurophysiolv 2008; 119: 1353–7. [DOI] [PubMed] [Google Scholar]
  • 14.Ažman D, Hrabač P, Demarin V. Use of multiple ultrasonographic parameters in confirmation of carpal tunnel syndrome. J Ultrasound Med 2018; 37: 879–9. [DOI] [PubMed] [Google Scholar]
  • 15.Hunderfund AN, Boon AJ, Mandrekar JN, Sorenson EJ. Sonography in carpal tunnel syndrome. Muscle Nerve 2011; 44: 485–91. [DOI] [PubMed] [Google Scholar]
  • 16.Ulaşli AM, Duymuş M, Nacir B, Rana Erdem H, Koşar U. Reasons for using swelling ratio in sonographic diagnosis of carpal tunnel syndrome and a reliable method for its calculation. Muscle Nerve 2013; 47: 396–402. [DOI] [PubMed] [Google Scholar]
  • 17.Fu T, Cao M, Liu F, Zhu J, Ye D, Feng X, et al. Carpal tunnel syndrome assessment with ultrasonography: value of inlet‐to‐outlet median nerve area ratio in patients versus healthy volunteers. PLoS One 2015; 10: e0116777. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Klauser AS, Halpern EJ, De Zordo T, Feuchtner GM, Arora R, Gruber J, et al. Carpal tunnel syndrome assessment with US: value of additional cross‐sectional area measurements of the median nerve in patients versus healthy volunteers. Radiology 2009; 250: 171–7. [DOI] [PubMed] [Google Scholar]
  • 19.Roll SC, Evans KD, Li X, Freimer M, Sommerich CM. Screening for carpal tunnel syndrome using sonography. J Ultrasound Med 2011; 30: 1657–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Ghasemi‐Esfe AR, Khalilzadeh O, Vaziri‐Bozorg SM, Jajroudi M, Shakiba M, Mazloumi M, et al. Color and power Doppler US for diagnosing carpal tunnel syndrome and determining its severity: a quantitative image processing method. Radiology 2011; 261: 499–506. [DOI] [PubMed] [Google Scholar]
  • 21.Dejaco C, Stradner M, Zauner D, Seel W, Simmet NE, Klammer A, et al. Ultrasound for diagnosis of carpal tunnel syndrome: comparison of different methods to determine median nerve volume and value of power Doppler sonography. Ann Rheum Dis 2013; 72: 1934–9. [DOI] [PubMed] [Google Scholar]

Articles from Australasian Journal of Ultrasound in Medicine are provided here courtesy of Australasian Society for Ultrasound in Medicine

RESOURCES