Abstract
We demonstrate single-shot non-diffracting light-sheet generation by controlling the spatial coherence of light. A one-dimensional coherent beam, created by either increasing the spatial coherence of an LED or decreasing the spatial coherence of a laser, makes it unnecessary to scan non-diffracting beams to generate light-sheets. We theoretically and experimentally demonstrate the equivalence between our method and a scanned light-sheet, and investigate the characteristics of the light-sheet in detail. Our method is easily implementable and universally applicable for high-resolution multicolor light-sheet fluorescence imaging.
Keywords: non-diffracting beams, light-sheet, spatial coherence, LED, laser
1. Introduction
Light-sheet illumination was used to investigate the physical properties of colloidal particles a century ago [1]. Since then, concepts from the technique such as orthogonal excitation and detection have found many applications [2]. Over the last two decades light-sheet illumination has been repurposed in light-sheet fluorescence microscopy (LSFM) for biomedical research, and has enabled fast and long-term volumetric imaging of biological specimens with a minimal light level [3–7].
A light-sheet is typically created by a cylindrical lens [3] or by scanning a focused Gaussian beam [8]. Since the imaging field-of-view is set by the Rayleigh range of the propagating Gaussian beam it is strongly coupled with the beam thickness. Thus, LSFM with a larger imaging area unavoidably accompanies a thicker illumination beam, yielding a poor signal-to-background ratio. To solve this problem, a light-sheet, generated by scanning a non-diffracting beam such as a Bessel beam [9, 10] or Airy beam [11], has been suggested. This has proven especially useful for high-resolution subcellular imaging due to its capability of providing a thin light-sheet for optical sectioning while maintaining a large field-of-view [10, 12]. However, the high peak excitation intensity of a scanning-based light-sheet is likely to increase irreversible photodamage and thus compromises LSFM’s superiority for noninvasive imaging of living samples [13, 14].
Recently, two intriguing methods have been reported to produce non-diffracting light-sheets. The first is field synthesis [15] where a focused and monochromatic laser line is scanned across an annular mask placed at the objective’s pupil plane. Light-sheets with different intensity profiles are generated at each scanning position, and the resulting time-averaged light-sheet is identical to a scanned Bessel beam. The second is a space-time light-sheet [16] where a diffraction grating and phase modulation system such as spatial light modulator (SLM) creates a tight correlation between the spatial and temporal frequencies in broadband incoherent light [17], and this generates universal propagation-invariant light-sheets. Compared to a scanned light sheet [10], field synthesis and space-time light-sheets both provide lower peak excitation intensities, which significantly reduces photodamage in biological specimens [15]. While their working principles are different, both approaches require high spatial coherence of light. Here, we show that controlling the spatial coherence of a light emitting diode (LED) or laser facilitates the generation of static non-diffracting light-sheets without a beam scanning module and/or SLM. We investigate the characteristics of our approach and discuss its implications on LSFM.
2. Single-shot non-diffracting light-sheet generation
Inspired by field synthesis [15], we reason that if numerous focused lines that are spatially incoherent from each other are simultaneously illuminated at the back focal plane (BFP) of objective, one can obtain the same light-sheet profile as the field synthesis [Fig. 1]. Their intensities are simply added up together at the image plane (IP) and this makes it unnecessary to scan and time-average the beam for the light-sheet generation. We note that to realize this idea, a one-dimensional (1D) coherent beam is required, i.e. incoherent along the x-axis but coherent along the y-axis at the conjugated image plane [Fig. 1].
Fig. 1.
Working principles of non-diffracting light-sheet generation by single-shot 1D coherent beam (top) compared with field synthesis that sequentially scans a focused line at different time points such as t1 or t4 and averages them (bottom). BFP and FT denote the back focal plane and Fourier transform, respectively.
Mathematically, it is straightforward to prove the equivalence between the resulting light-sheets generated by field-synthesis and our approach as follows. We assume that the coherence function of the 1D coherent beam for any two positions and at the BFP is:
| (1) |
where is the intensity. Here we have two assumptions: 1) the light source in the dimension is completely coherent and the coherence function is equal to 1 for any two positions ( and ); 2) the illumination intensity at BFP is uniform and could be regarded as a constant . After transmitting through the optical mask placed at the BFP, the coherence function could be written as [18]:
| (2) |
The amplitude point spread functions from two points at the BFP to any two points at the IP are represented as and , respectively, and they are expressed as where is a constant, is the wave vector and is the focal length of the objective lens. Then the coherence function propagating from the BFP to the IP can be described as [18]:
| (3) |
Since is equal to a Fourier transform of the mask’s transmittance at dimension at a fixed position , we represented it as . The intensity distribution at the IP is then calculated as:
| (4) |
where the right side in equation (4) represents a (coherent) focused line scanned across the BFP. It is worth noting that can be any mask with optical amplitude and/or phase modulation.
3. Experimental results
We demonstrated our concept experimentally as shown in Fig. 2. First, incoherent light from an LED (λ = 625 nm, M625L4) was collected and collimated by a condenser F1 (f1 = 20 mm, ACL2520U-A), and focused by a cylindrical lens CL (fCL = 25 mm, LJ4426). The beam passed through a narrow slit S (D = 10 μm, GS-10-N-CG; Applied Image) placed at the BFP of the cylindrical lens to control the spatial coherence. Then the slit was conjugated to an image plane using a relay system composed of a lens F2 (f2 = 50 mm, AC254-050-A) and an objective F3 (f3 = 40 mm, AC254-040-A). An annular ring (R1CA2000) with outer (d1) and inner (d2) diameters of 2 mm and 1.75 mm, respectively, was inserted at the BFP of the objective. Lenses and optomechanics were purchased from Thorlabs unless specified otherwise. The beam emanating from the slit is a 1D coherent beam and instantaneously produces numerous focused lines at the different positions of the BFP while illuminating the entirety of the annular mask.
Fig. 2.
Experimental scheme of single-shot static light-sheet generation using an LED. Ray colors denote individual light originated from different regions of the LED. CL, cylindrical lens; F1–2, lenses; IP, imaging plane; Obj, objective lens.
To measure the intensity profiles of the generated light-sheets, we placed a camera (DMK 33UX290; The Imaging Source) behind the objective and recorded images by moving the camera along the z-axis using a motorized stage driven by a servo motor (Thorlabs, PT1-Z8). For comparison, we first used a diode laser (λ = 638 nm, Cobolt) spatially filtered by a single mode fiber. In this case, a Bessel beam was generated as expected [Fig. 3(a)]. Its propagation length at the full width at half maximum (FWHM) was 6.90 mm, which was about 6 times longer than that of a Gaussian beam with a similar thickness [Fig. 3(d)]. In contrast, with 1D coherent light from LED, a static non-diffracting light-sheet was generated without beam scanning [Fig. 3(c)]. Its propagation length was 6.75 mm and the beam thickness was ~14.5 μm [Figs. 4(a) and (b)], which were the same as those of a laterally scanned Bessel beam [Fig. 3(b)]. This was obtained by convolution of the measured Bessel beam intensity and a line along the x-axis. The lateral field-of-view along the x-axis of the static non-diffracting light-sheet was ~10 mm. Note that by increasing the ratio d2/d1 one can readily prepare a non-diffracting light-sheet with a longer propagation length; however, this results in substantial side-lobes that are not desirable for fluorescence imaging. If the annular ring mask is omitted, one can create static Gaussian light-sheets as well [Fig. 3(d)].
Fig. 3.
Experimental results for a Bessel beam (a) and a scanned Bessel beam (b) generated with an annular ring and laser. Scale bars, δy = 40 μm and δz = 1 mm. (c,d) Static Bessel light-sheet (c) and Gaussian light-sheet (d) generated with 1D coherent beam from an LED.
Fig. 4.
Transverse (a) and propagation (b) profiles of Gaussian beam, Bessel beam, scanned Bessel beam and static Bessel light-sheet.
To examine the effect of the degree of spatial coherence, we measured the propagation intensity profiles with various slit widths. As the width increased from 10 μm to 40 μm, the beam thickness increased by 3.4-fold and the side-lobe fringes faded [19] while the propagation length remained almost constant [20][Fig. 5(a)]. The spatial coherence radius () at the BFP can be approximated as [18], which ensured high spatial coherence along the y-axis for our annular ring when used with the 10 μm slit.
Fig. 5.
(a) Intensity profiles along the y-axis for static Bessel light-sheets measured with different slit widths. (b) Dual color light-sheet generation at wavelengths of 430 nm and 625 nm. Scale bar, δy = 40 μm and δz = 1 mm.
Next, we examined the possibility of multicolor imaging. Two LEDs (λ = 430 nm and 625 nm) were combined by a dichroic beamsplitter and sent to the slit. The resulting light-sheets were approximately the same beam thickness [Fig. 5(b)], while the length of light-sheet at 430 nm was slightly shorter than that at 625 nm. The bandwidth of LED used (<20 nm) does not affect the properties of our light-sheets.
Lastly, instead of an LED, we used a diode laser (λ = 638 nm, Cobolt 06-MLD) but reduced its spatial coherence by coupling it into a multimode fiber (Ø400 μm, M28L01). A transmissive speckle reducer (Optotune, LSR-3005–12D-VIS) and a fiber shaker motor (ASLONG, JRF370–18260) were used to randomize speckle patterns and decrease the spatial coherence. For convenience, the beam was connected to a round-to-linear multimode fiber bundle (75 × Ø50 μm, custom design; Leoni) and the output beam was sent via a setup shown in Fig. 6(b). The same annular ring was used as in the LED experiment. This laser-based approach also generated a static non-diffracting light-sheet [Fig. 6(c)] with a negligible speckle pattern. We obtained ~0.5 mW of output power at the sample plane (0.36% efficiency), which was ~50 times higher illumination efficiency than an LED. However, it is possible to further improve the light efficiency by optimizing our setup. Approximately 60 fibers were mapped on the BFP and this was sufficient for a complete field synthesis [15].
Fig. 6.
(a, b) Schematic for preparing 1D coherent beam by a laser. (b) Experimental setup for single-shot nondiffracting light-sheet generation using a laser. F1 = 50 mm, FCL1 = 10 mm, FCL2 = 50 mm, FCL3 = 25 mm, Fobj = 40 mm. (c) The generated static Bessel light-sheet. The exposure time of camera was 20 ms. Scale bar, δy = 40 μm and δz = 1 mm.
4. Conclusions
We propose a new method to generate light-sheets by controlling the spatial coherence of light. A 1D coherent beam in conjunction with a spatial filter enables us to create non-diffracting light-sheets exhibiting uniform illumination and a long propagation length. Unlike other approaches, our method does not require lateral scanning and is also well suited to multicolor imaging. We can extend our approach to create other non-diffracting light-sheets as well [21, 22]. Either an LED or a laser can be employed once their spatial coherence is properly controlled, yielding a 1D coherent beam. It is promising to use a laser with tunable spatial coherence [23] such as degenerate cavity lasers [24]. Our simple approach has potential for advancing LSFM systems [25], including generation of multiple light-sheets in 3D [26, 27].
Acknowledgments
We thank Ayman Abouraddy for fruitful discussion and Benjamin Croop for critically reading our manuscript.
Funding
National Institutes of Health (R21GM131163) and National Science Foundation (1805200).
Footnotes
Disclosures
University of Central Florida has filed a patent application covering the work described in this paper.
References
- 1.Siedentopf H. and Zsigmondy R,”Uber Sichtbarmachung und Größenbestimmung ultramikoskopischer Teilchen, mit besonderer Anwendung auf Goldrubingläser,” Ann. Phys 315, 1–39 (1902). [Google Scholar]
- 2.Mappes T, Jahr N, Csaki A, Vogler N, Popp J, and Fritzsche W,”The Invention of Immersion Ultramicroscopy in 1912—The Birth of Nanotechnology?,” Angew. Chem. Int. Ed 51, 11208–11212 (2012). [DOI] [PubMed] [Google Scholar]
- 3.Huisken J, Swoger J, Del Bene F, Wittbrodt J, and Stelzer EHK,”Optical sectioning deep inside live embryos by selective plane illumination microscopy,” Science 305, 1007–1009 (2004). [DOI] [PubMed] [Google Scholar]
- 4.Keller PJ and Ahrens MB,”Visualizing whole-brain activity and development at the single-cell level using light-sheet microscopy,” Neuron 85, 462–483 (2015). [DOI] [PubMed] [Google Scholar]
- 5.Olarte OE, Andilla J, Gualda EJ, and Loza-Alvarez P,”Light-sheet microscopy: a tutorial,” Adv. Opt. Photonics 10, 111–179 (2018). [Google Scholar]
- 6.Girkin JM and Carvalho MT,”The light-sheet microscopy revolution,” J. Opt 20, 053002 (2018). [Google Scholar]
- 7.Gustavsson A-K, Petrov PN, and Moerner WE,”Light sheet approaches for improved precision in 3D localization-based super-resolution imaging in mammalian cells [Invited],” Opt. Express 26, 13122–13147 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Keller PJ, Schmidt AD, Wittbrodt J, and Stelzer EHK,”Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy,” Science 322, 1065–1069 (2008). [DOI] [PubMed] [Google Scholar]
- 9.Fahrbach FO, Simon P, and Rohrbach A,”Microscopy with self-reconstructing beams,” Nat. Photon 4, 780–785 (2010). [Google Scholar]
- 10.Planchon TA, Gao L, Milkie DE, Davidson MW, Galbraith JA, Galbraith CG, and Betzig E,”Rapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination,” Nat. Methods 8, 417–423 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Vettenburg T, Dalgarno HIC, Nylk J, Coll-Llado C, Ferrier DEK, Cizmar T, Gunn-Moore FJ, and Dholakia K,”Light-sheet microscopy using an Airy beam,” Nat. Methods 11, 541–544 (2014). [DOI] [PubMed] [Google Scholar]
- 12.Fahrbach FO, Gurchenkov V, Alessandri K, Nassoy P, and Rohrbach A,”Self-reconstructing sectioned Bessel beams offer submicron optical sectioning for large fields of view in light-sheet microscopy,” Opt. Express 21, 11425–11440 (2013). [DOI] [PubMed] [Google Scholar]
- 13.Power RM and Huisken J,”A guide to light-sheet fluorescence microscopy for multiscale imaging,” Nat. Methods 14, 360–373 (2017). [DOI] [PubMed] [Google Scholar]
- 14.Tang J, Ren J, and Han KY,”Fluorescence imaging with tailored light,” Nanophotonics 8, 2111–2128 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Chang B-J, Kittisopikul M, Dean KM, Roudot P, Welf ES, and Fiolka R,”Universal light-sheet generation with field synthesis,” Nat. Methods 16, 235–238 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Kondakci HE and Abouraddy AF,”Diffraction-free space–time light sheets,” Nat. Photon 11, 733–740 (2017). [Google Scholar]
- 17.Yessenov M, Bhaduri B, Kondakci HE, Meem M, Menon R, and Abouraddy AF,”Non-diffracting broadband incoherent space-time fields,” Optica 6, 598–607 (2019). [Google Scholar]
- 18.Saleh BEA and Teich MC, Fundamentals of Photonics, 3rd (Wiley, New York, 2019). [Google Scholar]
- 19.Fischer P, Brown CTA, Morris JE, López-Mariscal C, Wright EM, Sibbett W, and Dholakia K,”White light propagation invariant beams,” Opt. Express 13, 6657–6666 (2005). [DOI] [PubMed] [Google Scholar]
- 20.Turunen J, Vasara A, and Friberg AT,”Propagation invariance and self-imaging in variable-coherence optics,” J. Opt. Soc. Am. A 8, 282–289 (1991). [Google Scholar]
- 21.Chen B-C, Legant WR, Wang K, Shao L, Milkie DE, Davidson MW, Janetopoulos C, Wu XS, Hammer JA III, Liu Z, English BP, Mimori-Kiyosue Y, Romero DP, Ritter AT, Lippincott-Schwartz J, Fritz-Laylin L, Mullins RD, Mitchell DM, Bembenek JN, Reymann A-C, Boehme R, Grill SW, Wang JT, Seydoux G, Tulu US, Kiehart DP, and Betzig E,”Lattice light-sheet microscopy: Imaging molecules to embryos at high spatiotemporal resolution,” Science 346, 439 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Chang B-J and Fiolka R,”Light-sheet engineering using the Field Synthesis theorem,” J. Phys. Photonics 2, 014001 (2020). [Google Scholar]
- 23.Cao H, Chriki R, Bittner S, Friesem AA, and Davidson N,”Complex lasers with controllable coherence,” Nat. Rev. Phys 1, 156–168 (2019). [Google Scholar]
- 24.Chriki R, Nixon M, Pal V, Tradonsky C, Barach G, Friesem AA, and Davidson N,”Manipulating the spatial coherence of a laser source,” Opt. Express 23, 12989–12997 (2015). [DOI] [PubMed] [Google Scholar]
- 25.Power RM and Huisken J,”Putting advanced microscopy in the hands of biologists,” Nat. Methods 16, 1069–1073 (2019). [DOI] [PubMed] [Google Scholar]
- 26.Calisesi G, Castriotta M, Candeo A, Pistocchi A, D’Andrea C, Valentini G, Farina A, and Bassi A,”Spatially modulated illumination allows for light sheet fluorescence microscopy with an incoherent source and compressive sensing,” Biomed. Opt. Express 10, 5776–5788 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Ren Y-X, Wu J, Lai QTK, Lai HM, Siu DMD, Wu W, Wong KKY, and Tsia KK,”Parallelized volumetric fluorescence microscopy with a reconfigurable coded incoherent light-sheet array,” Light Sci. Appl 9, 8 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]