Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1999 Jan;37(1):233–234. doi: 10.1128/jcm.37.1.233-234.1999

Definition of False-Positive Reactions in Screening for Hepatitis C Virus Antibodies

Matthias Schröter 1,*, Heinz-Hubert Feucht 1, Peter Schäfer 1, Bernhard Zöllner 1, Susanne Polywka 1, Rainer Laufs 1
PMCID: PMC84219  PMID: 9854100

Abstract

The rate of false-positive hepatitis C virus enzyme immunoassay results was determined to be at least 10% among 1,814 reactive serum samples based on (i) negative results in an independent confirmation assay, (ii) negative PCR results, and (iii) no patients developing clinical or biochemical signs of hepatitis during a 1-year follow-up.


In daily laboratory routine, reliable diagnosis of hepatitis C virus (HCV) infection is not always possible by sole use of an HCV enzyme immunoassay (EIA), since it is well known that for a number of patients this assay produces false-positive results (4, 8, 17). Therefore, results obtained by EIA need to be confirmed by additional testing. However, the commercially available assay RIBA 2.0 (Chiron Corporation) does not fulfill the criteria defining a confirmation assay since it consists of recombinant proteins identical to those in the EIA (1, 5, 9). HCV PCR cannot be used for confirmation of positive EIA results, since a negative PCR result does not exclude the possibility of HCV infection with low-level viremia (below the limit of detection). Furthermore, PCR is too laborious and expensive to be used regularly as a confirmatory assay. Therefore, we have established an HCV strip immunoblot assay (SIA) (Universitäts-Krankenhaus Eppendorf [UKE] SIA) consisting of four recombinant proteins, derived from the core and three nonstructural regions (NS3, NS4, and NS5) of HCV, which are different from those used in the HCV EIA (5).

In the present study we compared the results of a second-generation HCV EIA with those of the UKE SIA for 2,283 serum samples. The aim was to assess the significance of positive results in the HCV EIA to define criteria for the performance of further tests to reliably diagnose HCV infection in the daily laboratory routine. Sera were drawn from 2,283 persons living in northern Germany around the city of Hamburg. They were sent to our laboratory under suspicion of HCV infection due to either elevated liver enzyme values (alanine aminotransferase, >45 U/liter) or clinical signs of hepatitis (jaundice and upper abdominal pain) or risk factors for parenterally transmitted diseases, such as chronic hemodialysis, blood transfusion, or intravenous drug use. At the time of investigation they tested negative for acute infection with HAV (anti-HAV immunoglobulin M antibodies) and HBV (hepatitis B surface antigen). Repeated examinations were performed as follow-up every 3 months for 1 year. For serological screening a second-generation HCV EIA (Abbott Laboratories, North Chicago, Ill.) was performed. For confirmation of HCV EIA results, sera were tested in parallel by the UKE SIA as previously described (5). The immunoblot assay was considered positive when antibodies to at least two different recombinant proteins were detectable. Reactivity against only a single protein was rated as an indeterminate result. For detection of HCV RNA reverse transcription-PCR was performed as previously described (6, 7).

The HCV EIA was negative for 469 samples, of which 456 (97%) were also negative by UKE SIA. For 13 samples the UKE SIA was considered indeterminate. All 469 of these sera were negative by HCV PCR, and none of the patients developed clinical or biochemical signs of hepatitis during the follow-up.

The HCV EIA was reactive for 1,814 samples, of which 1,394 (77%) were also positive by the UKE SIA (Table 1). However, in 240 cases (13%) the reactivity in the HCV EIA could not be confirmed by UKE SIA. Suitable specimens for HCV PCR were available for 193 of these 240 samples, and a positive PCR result was obtained with 13 samples. Of these, nine became positive by UKE SIA when retested after 3 months, which suggests that these patients had acquired HCV infection shortly prior to the first examination. In the remaining four patients, who repeatedly tested PCR positive despite a negative result by UKE SIA, immunosuppressing conditions could be found. One had a B-cell lymphoma, one was chronically hemodialyzed, and two practiced intravenous drug use. It has been shown earlier that in patients with immunosuppressive conditions, serological response is low or even absent (10, 14, 15). This could lead to negative or indeterminate results in serological assays although the individual suffers from infection with HCV (13). Therefore, for patients with known immunosuppressive disorders PCR should always be performed. The 180 initially PCR-negative subjects remained negative by UKE SIA and HCV PCR in repeated examinations during the follow-up. Moreover, these patients did not develop clinical or biochemical signs of hepatitis. This indicates that in at least these 180 samples (10%), false-positive results occurred. We must assume that the EIA was also false positive in the specimens for which no suitable material for PCR was available, since the UKE SIA remained negative and none of the patients developed clinical or biochemical signs of hepatitis during the follow-up. This indicates that as long as no better screening assays are commercially available every positive HCV EIA result must be confirmed.

TABLE 1.

Comparison of results of Abbott second-generation HCV EIA and UKE SIA for 2,283 serum samples

UKE SIA result (n = 2,283) No. (%) of samples with HCV EIA result
Positive (n = 1,814) Negative (n = 469)
Positive 1,394 (77) 0
Indeterminate 180 (10) 13 (3)
Negative 240 (13) 456 (97)

An indeterminate result in the UKE SIA was observed with 180 of the 1,814 EIA-positive samples (10%). Suitable specimens for HCV PCR were obtained for 134 of these 180 samples, and HCV RNA could be detected in 58 of them. During the follow-up full seroconversion was observed in four patients. All of them initially revealed antibodies directed solely against the NS3 protein of the UKE SIA. In follow-up samples, reactivity against additional recombinant proteins emerged. These results support the previous assumption that antibody reactivity against NS3 plays an important role in the early serological detection of HCV infection (5). Furthermore, a particularly high correlation has been found between HCV viremia and antibody reactivity against the c33c antigen of the commercially available RIBA (2). Samples with a positive result by HCV EIA and an indeterminate result by immunoblot assay must be subjected to PCR, since we detected HCV RNA in 43% of samples (58 of 134). The percentage of indeterminate results by the UKE SIA is remarkably low compared to that by RIBA 2.0 or 3.0 (2, 3, 11, 16). One reason for this might be that local isolates were used to establish the UKE SIA, since serological tests containing recombinant proteins of local isolates have been shown to have better sensitivity and specificity than commercially available assays (5, 12). However, this is unlikely to be the only reason, since the UKE SIA was evaluated with serum samples containing a variety of HCV genotypes as previously described (5).

The diagnosis HCV positive has a deep impact on the life of the afflicted person. Therefore, it must be reached as reliably as possible. Our data indicate that the widely used HCV EIA produces a high percentage (10%) of false-positive results. Compared to other screening assays, e.g., human immunodeficiency virus EIAs, this is unacceptably high. Therefore, confirmation of every positive HCV EIA result by supplemental tests is mandatory. As we have shown with our in-house UKE SIA, one possibility for improving the reliability of HCV diagnosis is to introduce proteins into the confirmation assay which are different from those used in the screening assay.

REFERENCES

  • 1.Bresters D, Zaaijer H L, Cuypers H T M, Reesing H W, Winkel I N, van Exel-Oehlers P J, van Drimmelen A A J, Jansen P L M, van der Poel C L, Lelie P N. Recombinant immunoblot assay reaction patterns and hepatitis C virus RNA in blood donors and non-A, non-B hepatitis patients. Transfusion. 1993;33:634–638. doi: 10.1046/j.1537-2995.1993.33893342743.x. [DOI] [PubMed] [Google Scholar]
  • 2.Chicheportiche C, Cantaloube J F, Biagini P, Aumont P, Donnadieu F, Escher J, Larabi F, Zepitelli J P. Analysis of ELISA hepatitis C virus-positive blood donors population by polymerase chain reaction and recombinant immunoblot assay (RIBA). Comparison of second and third generation RIBA. Acta Virol. 1993;37:123–131. [PubMed] [Google Scholar]
  • 3.Damen M, Zaaijer H L, Cuypers H T, Vrielink H, van der Poel C L, Reesink H W, Lelie P N. Reliability of the third-generation recombinant immunoblot assay for hepatitis C virus. Transfusion. 1995;9:745–749. doi: 10.1046/j.1537-2995.1995.35996029158.x. [DOI] [PubMed] [Google Scholar]
  • 4.Dow B C, Coote I, Munro H, McOmish F, Yap P L, Simmonds P, Follet E A C. Confirmation of hepatitis C virus antibody in blood donors. J Med Virol. 1993;41:215–220. doi: 10.1002/jmv.1890410309. [DOI] [PubMed] [Google Scholar]
  • 5.Feucht H H, Zöllner B, Polywka S, Laufs R. Study on reliability of commercially available hepatitis C virus antibody tests. J Clin Microbiol. 1995;33:620–624. doi: 10.1128/jcm.33.3.620-624.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Feucht H H, Zöllner B, Schröter M, Altrogge H, Laufs R. Tear fluid of hepatitis C virus carriers could be infectious. J Clin Microbiol. 1995;33:2202–2203. doi: 10.1128/jcm.33.8.2202-2203.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Feucht H H, Zöllner B, Schröter M, Hoyer A, Sterneck M, Polywka S. Distribution of genotypes and response to alpha interferon in patients with hepatitis C virus infection in Germany. Eur J Clin Microbiol Infect Dis. 1996;15:128–132. doi: 10.1007/BF01591485. [DOI] [PubMed] [Google Scholar]
  • 8.Gretch D, Lee W, Corey L. Use of aminotransferase, hepatitis C antibody, and hepatitis C polymerase chain reaction RNA assays to establish the diagnosis of hepatitis C virus infection in a diagnostic virology laboratory. J Clin Microbiol. 1992;30:2145–2149. doi: 10.1128/jcm.30.8.2145-2149.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Lelie P N, Cuypers H T, Reesink H W, van der Poel C L, Winkel I N, Bakker E, van Exel-Oehlers P J, Vallari D, Allain J P, Mimms L. Patterns of serological markers in transfusion-transmitted hepatitis C virus infection using a second-generation HCV assay. J Med Virol. 1992;37:203–209. doi: 10.1002/jmv.1890370310. [DOI] [PubMed] [Google Scholar]
  • 10.Lok A S, Chien D, Choo Q L, Chan T M, Chien E K, Cheng I K, Houghton M, Kuo G. Antibody response to core, envelope and nonstructural hepatitis C virus antigen: comparison of immunocompetent and immunosuppressed patients. Hepatology. 1993;18:497–502. [PubMed] [Google Scholar]
  • 11.McHutchison J G, Person J L, Govindarajan S, Valinluck B, Gore T, Lee S R, Nelles M, Polito A, Chien D, DiNello R, Quan S, Kuo G, Redeker A G. Improved detection of hepatitis C virus antibodies in high-risk populations. Hepatology. 1992;15:19–25. doi: 10.1002/hep.1840150105. [DOI] [PubMed] [Google Scholar]
  • 12.Neville J A, Prescott L E, Bhattacherjee V, Adams N, Pike I, Rodgers B, El-Zayadi A, Hamid S, Dusheiko G M, Saeed A A, Haydon G H, Simmonds P. Antigenic variation of core, NS3, and NS5 proteins among genotypes of hepatitis C virus. J Clin Microbiol. 1997;35:3062–3070. doi: 10.1128/jcm.35.12.3062-3070.1997. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Pawlotzky J-M, Fleury A, Choukroun V, Deforges L, Roudot-Thoraval F, Aumont P, Duval J, Dhumeaux D. Significance of highly positive c22-3 “indeterminate” second-generation hepatitis C virus (HCV) recombinant immunoblot assay (RIBA) and resolution by third-generation HCV-RIBA. J Clin Microbiol. 1994;32:1357–1359. doi: 10.1128/jcm.32.5.1357-1359.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Pereira B J G, Milford E L, Kirkman R L, Levey A S. Transmission of hepatitis C virus by organ transplantation. N Engl J Med. 1991;325:454–460. doi: 10.1056/NEJM199108153250702. [DOI] [PubMed] [Google Scholar]
  • 15.Schröter M, Feucht H H, Schäfer P, Zöllner B, Laufs R. High percentage of seronegative HCV-infections in hemodialysis patients: the need for PCR. Intervirology. 1997;40:277–278. doi: 10.1159/000150558. [DOI] [PubMed] [Google Scholar]
  • 16.Tobler L H, Busch M P, Wilber J, Dinello R, Quan S, Polito A, Kochesky R, Bahl C, Nelles M, Lee S R. Evaluation of indeterminate c22-3 reactivity in volunteer blood donors. Transfusion. 1994;2:130–134. doi: 10.1046/j.1537-2995.1994.34294143940.x. [DOI] [PubMed] [Google Scholar]
  • 17.van der Poel C L, Cuypers H T, Reesing H W, Weiner A J, Quan S, DiNello R, van Boven J J P, Winkel I N, Mulder-Folkerts D, Exel-Oehlers P J, Schaasberg W, Leentvar-Kuypers A, Polito A, Houghton M, Lelie P N. Confirmation of hepatitis C infection by new four-antigen recombinant immunoblot assay. Lancet. 1991;337:317–319. doi: 10.1016/0140-6736(91)90942-i. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES