Abstract
The most affected disease in recent years is Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2) that is notable as COVID-19. It has been started as a disease in one place and arisen as a pandemic throughout the world. A serious health problem is developed in the lungs due to the effect of this coronavirus. Sometimes it may result in death as a consequence of extensive alveolar damage and progressive respiratory failure. Hence, early detection and appropriate diagnosis of corona virus in patient’s body is very essential to save the lives of affected patients This work evolves a Silicon (Si) based label-free electrical device i.e. the reduced graphene oxide field-effect transistor (rGO FET) for SARS-CoV-2 detection. Firstly rGO FET functionalized with SARS-CoV-2 monoclonal antibodies (mAbs). Then the rGO FET characteristic response is observed to detect the antibody-antigen reaction of SARS-CoV-2 with different molar ranges. The developed GFET shows better performance towards the drain current and limit-of-detection (LoD) up to 2E-18 M. Therefore, we believe that an intense response was observed than the earlier developed devices and signifies impressive capability for subsequent implementation in point-of-care (PoC) diagnostic tests.
Keywords: FET, SARS-CoV-2, rGO, Biosensor, Limit of detection
Acknowledgements
The authors would like to acknowledge Indian Institute of Technology Hyderabad (IIT Hyderabad) for backing us with some experimental work carried out and the tool (COMSOL Semiconductor Module) required for simulating this work. And M. Durga Prakash thankfully acknowledges this publication as an outcome of the R&D work undertaken project under the Start-up Research Grant (File No.: SRG/2019/002236) scheme of Department of Science and Technology (DST), Government of India, being Science Engineering Research Broad (SERB).
Author Contributions
M. Durga Prakash, B. Vamsi Krsihna and Shaik Ahmadsaidulu: Conceptualization; M. Durga Prakash, B. Vamsi Krsihna and Shaik Ahmadsaidulu: investigation; M. Durga Prakash, Shaik Ahmadsaidulu, B. Vamsi Krsihna, and B: resources; M. Durga Prakash, Shaik Ahmadsaidulu, B. Vamsi Krsihna and Surapaneni Sai Tarun Teja, D Jayanthi, Alluri Navaneetha and P Rahul Reddy: data curation; M. Durga Prakash, Surapaneni Sai Tarun Teja, D Jayanthi, Alluri Navaneetha, P Rahul Reddy and Shaik Ahmadsaidulu: writing—original draft preparation; M. Durga Prakash, B. Vamsi Krsihna, and Shaik Ahmadsaidulu: writing—review and editing; M. Durga Prakash and Shaik Ahmadsaidulu: visualization; M. Durga Prakash: supervision;
Data Availability
No supplementary materials.
Declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Human and Animal Rights
This article does not contain any studies with human or animal subjects.
Consent to Participate
Additional informed consent was obtained from M. Durga Prakash identifying information is included in this article.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Wu F, Zhao S, Yu B, Chen YM, Wang W, Song ZG, Hu Y, Tao ZW, Tian JH, Pei YY, Yuan ML (2020) A new coronavirus associated with human respiratory disease in China. Nature 579:265–269. 10.1038/s41586-020-2008-3 [DOI] [PMC free article] [PubMed]
- 2.WHO. Novel Coronavirus (2019-nCoV) Situation Report – 1. https://www.who.int/docs/default-source/coronaviruse/situationreports/20200121-sitrep-1-2019-ncov.pdf?sfvrsn=20a99c10_4 (2020-04-15)
- 3.Coronavirus Disease (COVID-19) Pandemic. Available online: https://www.who.int/ru/emergencies/diseases/novel-coronavirus-2019. Accessed 1 July 2021
- 4.Jayaweera M, Perera H, Gunawardana B, Manatunge J (2020) Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy. Environ Res 188:109819. 10.1016/j.envres.2020.109819 [DOI] [PMC free article] [PubMed]
- 5.Echtioui A, ZouchW, Ghorbel M, Mhiri C, Hamam H. Detection methods of COVID-19. SLAS Technol 25(6):566–572. 10.1177/2472630320962002 [DOI] [PMC free article] [PubMed]
- 6.FroylaÂn Ibarra N, Montenegro Y, Vera C, Boulard H, Quiroz J, Flores P, Ochoa (1998) Comparison of three ELISA tests for seroepidemiology of bovine fascioliosis. Vet Parasitol 77:229–236. 10.1016/S0304-4017(98)00111-3 [DOI] [PubMed]
- 7.BV, Krsihna S, Ravi, Prakash MD. Recent developments in graphene based field effect transistors. Mater Today Proc. 10.1016/j.matpr.2020.07.678 [DOI] [PMC free article] [PubMed]
- 8.Ahmadsaidulu S, Durga Prakash M (2021) Impacts of gate length and doping concentrations on the performance of silicon nanowire Field effect Transistor. Mater Today Proc 46(Part 9):3693–3698. 10.1016/j.matpr.2021.01.849
- 9.Matta DP, Vanjari SRamaK, Sharma CS, Singh SG (2016) Ultrasensitive, label free, chemiresistive nanobiosensor using multiwalled carbon nanotubes embedded electrospun SU-8 nanofibers. Sensors 16(9):1354. 10.3390/s16091354 [DOI] [PMC free article] [PubMed]
- 10.Prakash MD, Tripathy S, Vanjari SRamaK, Sharma CS, Singh SG (2016) An ultrasensitive label free nanobiosensor platform for the detection of cardiac biomarkers. Biomed Microdevices 18(6):1–10. 10.1007/s10544-016-0126-3 [DOI] [PubMed]
- 11.Fan Yang G-J, Zhang Silicon nanowire-transistor biosensor for study of molecule-molecule interactions. Rev Anal Chem. 2014;33(2):95–110. doi: 10.1515/revac-2014-0010. [DOI] [Google Scholar]
- 12.Fernando Patolsky, Brian P, Timko G, Zheng, Lieber CM. Nanowire-based nanoelectronic devices in the life sciences. MRS Bull. 2007;32(2):142–149. doi: 10.1557/mrs2007.47. [DOI] [Google Scholar]
- 13.Tabatabaian M (2015) CFD module. Stylus Publishing, LLC, Sterling
- 14.Multiphysics C (2015) Chemical reaction engineering module user’s guide. COMSOL AB, Stockholm
- 15.Hajji L, Kolsi W, Hassen AAAA, Al-Rashed MN, Borjini MA, Aichouni Finite element simulation of antigen-antibody transport and adsorption in a microfluidic chip. Phys E. 2018;104:177–186. doi: 10.1016/j.physe.2018.07.034. [DOI] [Google Scholar]
- 16.Adriano Ambrosi CK, Chua A, Bonanni, Pumera M. Lithium aluminum hydride as reducing agent for chemically reduced graphene oxides. Chem Mater. 2012;24:2292–2298. doi: 10.1021/cm300382b. [DOI] [Google Scholar]
- 17.Puurunen RL (2005) Surface chemistry of atomic layer deposition: A case study for the trimethylaluminum/water process. J Appl Phys 97:121301. 10.1063/1.1940727
- 18.Shen M-Y, Li B-R, Li Y-K (2014) Silicon nanowire field-effect-transistor based biosensors: From sensitive to ultra-sensitive. Biosensors Bioelectronics 60:101–111 [DOI] [PubMed]
- 19.Lieber CM. Nanoscale science and technology: building a big future from small things. MRS Bull 28(07):486–491. 10.1557/mrs2003.144
- 20.Yue Wu J, Xiang C, Yang W, Lu, Charles M, Lieber. Single-crystal metallic nanowires and metal/semiconductor nanowire heterostructures. Nature 430(6995):61–65 [DOI] [PubMed]
- 21.Zheng G, Lu W, Jin S, Lieber CM (2004) Synthesis and fabrication of high-performance n‐type silicon nanowire transistors. Adv Mater 16(21):1890–1893
- 22.Cui Y, Wei Q, Park H, Lieber CM (2001) Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species.. Science 293(5533):1289–1292 [DOI] [PubMed]
- 23.Chunyu, Chan, et al. A microfluidic flow-through chip integrated with reduced graphene oxide transistor for influenza virus gene detection. Sens Actuators B. 2017;251(1November):927–933. doi: 10.1016/j.snb.2017.05.147. [DOI] [Google Scholar]
- 24.Lee I-K, Jeun M, Jang H-J, Cho W-J, Lee KH (2015) A self-amplified transistor immunosensor under dual gate operation: highly sensitive detection of hepatitis B surface antigen. Nanoscale 7:16789–16797. 10.1039/C5NR03146J [DOI] [PubMed]
- 25.Ishikawa FN, Curreli M, Olson CA, Liao HI, Sun R, Roberts RW, Cote RJ, Thompson ME, Zhou C. Importance of controlling nanotube density for highly sensitive and reliable biosensors functional in physiological conditions. ACS Nano. 2010;4:6914–6922. doi: 10.1021/nn101198u. [DOI] [PubMed] [Google Scholar]
- 26.Hsu Y-R, Lee G-Y, Chyi J-I, Chang C-k, Huang C-C, Hsu C-P, Huang T-h, Ren F, Wang Y-L. Detection of Severe Acute Respiratory Syndrome (SARS) coronavirus nucleocapsid 682 protein using AlGaN/GaN high electron mobility transistors. ECS Trans. 2013;50:681. doi: 10.1149/05006.0239ecst. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Chua JH, Chee R-E, Agarwal A, Wong SM, Zhang G-J (2009) Label-free electrical detection of cardiac biomarker with complementary metal-oxide semiconductor-compatible silicon nanowire sensor arrays. Anal Chem 81(15):6266–6271. 10.1021/ac901157x [DOI] [PubMed]
- 28.Xiaoyan, Zhang et al (2020) Electrical probing of COVID-19 spike protein receptor binding domain via a graphene field-effect transistor. ArXiv:2003.12529 [Cond-Mat, Physics: Physics]. http://arxiv.org/abs/2003.12529
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
No supplementary materials.
