Table 1. Parameters Obtained from Fitting the Stress Relaxation Plots of PCL-PX with Stretched Exponential Functiona.
temperature (°C) | τ (s) | β |
---|---|---|
80 | 3204 | 0.85 |
100 | 957 | 0.9 |
120 | 349 | 0.89 |
140 | 122 | 0.87 |
160 | 42 | 0.85 |
τ: Characteristic relaxation time, β: stretch factor, indicative of the distribution of relaxation times.