Significance
Violent expiratory events like coughs and sneezes represent an important route for the spread of respiratory viruses, such as SARS-CoV-2, the virus responsible for COVID-19. We use finely resolved experiments and simulations to quantify how the turbulent cloud of moist air exhaled during a sneeze largely increases the airborne time and the lifespan of virus-loaded droplets. By providing visualizations of the spatial distribution of the virus copies, we highlight the high infection risk associated with droplets that remain airborne in the near proximity of an infected individual. The present study aims at raising awareness among public health authorities about this infection risk, which is grossly underestimated by current guidelines.
Keywords: COVID-19, airborne, infectious disease, SARS-CoV-2, public health
Abstract
After the Spanish flu pandemic, it was apparent that airborne transmission was crucial to spreading virus contagion, and research responded by producing several fundamental works like the experiments of Duguid [J. P. Duguid, J. Hyg. 44, 6 (1946)] and the model of Wells [W. F. Wells, Am. J. Hyg. 20, 611–618 (1934)]. These seminal works have been pillars of past and current guidelines published by health organizations. However, in about one century, understanding of turbulent aerosol transport by jets and plumes has enormously progressed, and it is now time to use this body of developed knowledge. In this work, we use detailed experiments and accurate computationally intensive numerical simulations of droplet-laden turbulent puffs emitted during sneezes in a wide range of environmental conditions. We consider the same emission—number of drops, drop size distribution, and initial velocity—and we change environmental parameters such as temperature and humidity, and we observe strong variation in droplets’ evaporation or condensation in accordance with their local temperature and humidity microenvironment. We assume that 3% of the initial droplet volume is made of nonvolatile matter. Our systematic analysis confirms that droplets’ lifetime is always about one order of magnitude larger compared to previous predictions, in some cases up to 200 times. Finally, we have been able to produce original virus exposure maps, which can be a useful instrument for health scientists and practitioners to calibrate new guidelines to prevent short-range airborne disease transmission.
Respiratory viruses can be transmitted among human subjects via three main routes. First, direct contact and fomites, where a healthy individual comes into direct contact with an infected person (direct contact) or touches a contaminated surface (fomites). Second, through the droplet transmission that occurs in the proximity of an infected person, who exhales large and small respiratory droplets containing the virus. Third, through the airborne transmission of smaller droplets and particles (droplet nuclei), which remain airborne over a much longer time, traveling farther distances than droplet transmission. While the latest research suggests that direct contact and fomites are unlikely to be a major source of infection for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (1, 2), understanding the role played by the latter two contributions is crucial to design effective guidelines for pathogens transmission prevention.
Conventionally, and according to World Health Organization guidelines (3), droplets larger than in diameter are referred to as respiratory droplets (droplet transmission), while those smaller than in diameter are defined as droplet nuclei (airborne transmission). This threshold has been widely used to define public health guidelines and to design infection control interventions for healthcare workers (4). The current pandemic, however, highlighted the limitations of these guidelines and made it clear that new research should be embraced to revise these recommendations. Indeed, the threshold used to distinguish between droplet transmission and airborne transmission and its scientific rationale are highly questionable (5, 6): The aerodynamic behavior of droplets, ballistic for respiratory droplets and aerosol-like for droplet nuclei, strongly depends on the local flow conditions. Recent works suggest that a much larger threshold () (7, 8) better differentiates between large and small droplet dynamics. Likewise, the better understanding of turbulence gained in the last 50 y has shown how the evaporation process is extremely complex (9–11) and cannot be captured with simplified models, like those employed by Wells (12). Finally, from a medical perspective, it is evident how the distinction between large droplet and small droplet (airborne) diseases and its connection with short- and long-range transmission is rather weak, and, for many respiratory infections, the predominant route depends on the specific setting (13, 14).
A key step toward understanding the routes of pathogens transmission must rely on the study of the fluid dynamics, as it plays a crucial role in almost every aspect of disease spreading (10, 15). Thanks to recent experimental and numerical advancements, we can have access to detailed time- and space-resolved quantities. In this work, using the most recent experimental and numerical methodologies, we investigate the evaporation and dispersion dynamics of the respiratory droplets released during a sneeze in four different ambient conditions (temperature and relative humidity). Although sneezing is not a known symptom of COVID-19, it can significantly contribute to the spreading of disease, as it is a powerful event that generates thousands of virus-laden droplets and is also common of many diseases and allergies (16). Then, building on these results, and using virological data, we evaluate the transport of the viral copies, providing graphical visualizations of the infection risk at close distance to an infected subject. Our findings suggest that predictions based on the models adopted in current guidelines are largely unsatisfactory, leading to a dangerous underestimation of the infection risk. In particular, current guidelines underestimate the infectious potential associated with the short-range airborne route (6, 17, 18), that is, the infection risk associated with small droplets and droplet nuclei that remain airborne in the proximity of an infected individual and that may readily penetrate and deposit in the upper and lower respiratory tract (19).
Results and Discussion
We start by comparing the behavior predicted by our experiments and simulations of a violent expiratory event. In particular, we consider the sneeze ejected from a human subject without any face covering (please refer to SI Appendix for a discussion on face covering). The results obtained are benchmarked against theoretical scaling laws available for the two phases characterizing the expiratory event: jet and puff (20–22). Then, high-fidelity simulations are used to characterize the dispersion and evaporation of the respiratory droplets in different ambient conditions. These results are compared with the predictions obtained from models currently employed in public health guidelines. Finally, we try to bridge fluid dynamics and virological data on SARS-CoV-2 to characterize the virus exposure, discussing the risk associated with droplets of different sizes.
Sneezing Event: Simulations and Experiments.
To assess the reliability of numerical simulations in accurately reproducing a sneezing event, we start by benchmarking simulation results against those obtained from the experiments performed in the Technische Universität Wien laboratory. Due to the impossibility of performing experiments in which temperature, vapor mass fraction, and velocity fields are recorded simultaneously, we focus on the ability of simulations and experiments to accurately capture the flow structures and the dynamics of the sneeze. As, in this section, we do not investigate the evaporation process, we consider a neutrally buoyant jet having the same temperature and humidity as the ambient ( °C and relative humidity ). The jet is seeded with tracers (monodispersed silicone oil droplets having a diameter equal to ), which are used for flow visualization and, specifically, to track the advancement of the jet front. For simulations, the inflow condition is obtained from a gamma probability distribution function (23), which mimics the airflow generated by a sneezing event. Likewise, experiments have been designed to reproduce an inlet condition that is repeatable and similar to that adopted in the simulations. Please refer to Materials and Methods and SI Appendix for further details.
To quantitatively compare the results, we consider the time evolution of the jet front. Results are also benchmarked against the theoretical scaling laws available in the literature (20–22). In particular, considering the finite duration of a sneezing event (and, consequently, the finite time during which momentum is injected in the environment), we can distinguish between two different phases: 1) jet phase, linked to the early jet evolution when momentum is continuously provided (constant momentum flux); and 2) puff phase, linked to the late evolution where momentum injection ceases and the jet momentum remains constant. Using the self-similarity hypothesis, two scaling laws for the distance traveled by the jet front can be derived (24); for the starting jet phase (constant momentum flux), the distance traveled by the jet front grows over time as , while, for the puff phase (constant momentum), the penetration distance grows as .
Fig. 1 shows the evolution of the front of the jet obtained from simulations (red points) and experiments (blue points with error bars). As reference, the theoretical scaling laws for the jet and puff phase are reported with two dashed lines. For the jet phase, we observe a very good agreement between experiments and simulations. In particular, the resulting least-squares power-law fits are for the experiments and for the simulations. Present results are also in good agreement with the analytical scaling law. A detailed quantification on the goodness of the fittings proposed is presented in SI Appendix. The very small discrepancy observed between our results and the theoretical scaling law can be traced back to the constant momentum flux hypothesis used to derive the scaling. This assumption is only partially satisfied, as, in the very first stage of the sneeze (), there is a rapid, but not instantaneous, increase of the inlet velocity and thus of the momentum flux. Moving to the puff phase, there is a remarkable decrease of the momentum flux, and the distance traveled by the jet front deviates from the jet scaling law and approaches the puff scaling law. Even in this later stage, an overall good agreement is observed between experiments and simulations. For both curves (experiments and simulations), the exponent of the power-law least-squares fitting approaches the value , as suggested by the theoretical scaling law. To further compare simulations and experiments, we measured the semicone angle of the jet, obtaining very similar values among experiments () and simulations (). These findings are also in agreement with previous investigations on human respiratory activities (21). Additional comparisons between simulations and experiments are available in SI Appendix.
Sneezing Event Simulations.
Once having assessed the reliability of the numerical framework, we use numerical simulations to study the dispersion and evaporation of respiratory droplets resulting from a sneeze. We study four different ambient conditions: two temperatures ( °C and °C) and two relative humidities ( and ). These simulations are performed using the same numerical setup discussed before (see Materials and Methods and SI Appendix for details).
Fig. 2 shows a graphical representation of the sneezing event reproduced by the simulations; Fig. 2 A and B refers to the °C and case, while Fig. 2 C and D refers to the °C and case. For each case, two different time instants, and , are shown; the background is colored by the local (white, low; black, high), while the dimension (not in scale) and color of the respiratory droplets correspond to their diameter (red, small; white, large). At the beginning (Fig. 2 A and C), for both cases, most of the droplets are within the turbulent saturated cloud emitted by the sneezing jet. Only a few droplets, with diameter larger than 100 (white), located in the front of the jet leave the cloud. Later in time (Fig. 2 B and D), the largest droplets start to settle down and thus to significantly move in the vertical direction. Conversely, most of the other droplets remain suspended in the vapor cloud generated by the sneezing jet as their settling time is longer (e.g., for a droplet) (12). The effect of buoyancy is also apparent. Since the jet is characterized by a higher temperature (smaller density) than the environment, the cloud starts to move upward, carrying small droplets as well. This effect is more evident for the low-temperature cases. Finally, it is worth observing that already after , the front of the jet with the transported droplets has already traveled about 1 m away from the infected individual.
Evaporation of Respiratory Droplets.
To evaluate the infection risk associated with droplets of different sizes, we first evaluate the lifetime of the respiratory droplets. To this aim, we compute the time required by each droplet to complete the evaporation process, reaching its terminal size determined by the presence of nonvolatile elements. Indeed, since respiratory liquid contains salt and proteins (25–28), droplets evaporate until they reach a critical size, forming droplet nuclei (water and nonvolatile evaporation residua), which may remain suspended. The volume fraction of nonvolatile elements varies between individuals and is, on average, about in volume (25–29), which correspond to a dry nuclei size of about of the initial droplet diameter. Fig. 3, Right shows the resulting evaporation times for the different ambient conditions tested. The evaporation times are reported according to the initial droplet diameter, and, for each class of diameters, we compute the probability of obtaining a given evaporation time. The sample plot on Fig. 3, Left guides the reading of Fig. 3, Right. For any given initial diameter, the leftmost part of the distribution marks the shortest evaporation time, while the rightmost part of the distribution marks the longest evaporation time; empty black circles identify the mean evaporation time for each initial diameter. The distribution is colored by the probability of each evaporation time (blue, low probability; yellow, high probability). Present results have been compared with the evaporation time predicted by the constant temperature model (12, 30), which is currently employed in most public health guidelines. This model, assuming an isolated droplet at constant ambient temperature, leads to the so-called law, which predicts that the evaporation time is proportional to the initial diameter squared (and thus to the initial droplet surface). The predicted evaporation time (or, more precisely, the time required for a droplet to shrink down to 30% of its initial diameter) is reported with a red solid line as a function of the diameter: According to the law, small droplets evaporate almost immediately, while a much longer time is required for larger droplets. We highlight how the evaporation process obtained from simulations is different from that predicted by the model. Indeed, according to the law, only droplet nuclei should be present beyond the red line, which marks the evaporation time predicted with the constant temperature model. However, simulations show a completely different picture, with most of the droplets completing the evaporation process well beyond the predicted time. The slower evaporation dynamics of respiratory droplets is very pronounced for the high relative humidity cases (Fig. 3 B and D), where only droplets smaller than fully evaporate within . It is worth mentioning that, for the °C and case, the presence of a supersaturated region induced by the warm humid exhaled air (Fig. 2 A and B) produces an initial condensation of smaller droplets. Hence, in the first phase, droplets grow in size (11, 31) instead of evaporating and shrinking.
A similar trend, but less marked, can be observed for the low-humidity cases, where, for the most favorable case (Fig. 3C), almost all droplets with a size smaller than reach their final size. The resulting mean evaporation times obtained from simulations are thus larger (by at least one order of magnitude) than those predicted from the constant temperature model, as also observed in recent studies (11, 31). This dramatic slowdown of the evaporation process traces back to the motion of the droplets and to the local thermodynamic conditions they sample. Indeed, most of the droplets are exposed to the warmer and more humid conditions that characterize the exhaled cloud (20, 32) and to their fluctuations produced by turbulence (22). As the evaporation rate of the droplets is determined by the local humidity value at the droplet position, which is much higher than the expected environmental value, this results in a much slower evaporation (i.e., a much longer evaporation time). Although the resulting evaporation times are much larger than -law predictions, it is worth observing that the -law scaling seems to still bear some universality. Indeed, for the high-temperature cases (Fig. 3 C and D), the mean evaporation times seem to follow a similar scaling (but with a different prefactor). However, when low temperatures and high humidities are considered (Fig. 3 A and B), the presence of condensation in the early stages of the expiratory event extensively modifies the evaporation dynamics, and the -law scaling does not hold anymore.
Besides, the formation of the droplet nuclei can also be appreciated. For any given diameter, evaporated droplets shrink down to the critical size determined by the presence of nonvolatile matter (30% of the initial diameter). The dispersion of these nuclei is critical in disease transmission, as they carry a relatively large amount of bacteria and viruses (14, 33), which may remain infectious for a considerable amount of time, traveling long distances (e.g., for SARS-CoV-2, the half-life time in aerosol is ). The presence of droplet nuclei is observed in those cases characterized by a faster evaporation dynamics (Fig. 3 A, C, and D), while, for the case C and (Fig. 3D), nuclei formation is strongly delayed, as the evaporation process is hindered by the higher local relative humidity.
Virus Exposure Maps.
To evaluate the infection risk, we present the virus exposure maps. Specifically, we compute the cumulative number of virus copies that go past a control area in different domain locations. This type of evaluation requires precise information on the viral load for SARS-CoV-2. However, in archival literature, this information is characterized by large uncertainty, and the reported viral loads differ by several orders of magnitude (34–40). Indeed, viral load measurements are not only influenced by the method used to test the swab, but viral load also exhibits strong variations during the different stages of the infection (38, 39, 41), being influenced by the severity of symptoms (42–44) and many other factors as well, among which are age, sex, and droplet size (39, 45, 46). To bypass this uncertainty, we present our results in a dimensionless form, normalized by the total number of virus copies ejected and assuming a uniform viral load across all droplets at the time of their ejection. The dimensional concentration of virions can be calculated by multiplying the data from the normalized virus exposure maps for the viral load (an indicative value is copies per mL, for an individual with severe symptoms) (37, 38) and the ejected liquid volume (). As the time scale of the present simulations () is much smaller than the half-life time (47, 48) in aerosol of SARS-CoV-2 (about ), we do not consider any viral load decay.
Fig. 4 shows the virus exposure obtained from the four ambient conditions tested, which are calculated counting the cumulative number of virus copies (contained inside the droplets) passing through a control area. For all simulated cases, we observe a core region (green) characterized by a rather uniform value of exposure and some hotspots characterized by larger values of exposure, up to 10 times more. This behavior is attributed to the contemporary presence of droplets of very different sizes. Large droplets (more than ) carry a high number of virus copies (proportional to the initial droplet volume) and produce hotspots of virus concentration, as their number is low; conversely, small droplets (less than ) carry a lower number of virus copies and produce a more uniform exposure level, as their number is higher and they disperse more uniformly. The presence of exposure hotspots (and thus of droplets larger than ) extends up to . Indeed, these larger droplets follow almost ballistic trajectories and soon settle to the ground. The core region is surrounded by an outer region, characterized by a smaller level of exposure, that extends farther in space. This outer region is generated by smaller droplets and droplet nuclei, which reach this outer region later in time (), when the majority of the larger droplets have already settled to the ground and most of the smallest ones have completed the evaporation process (Fig. 3).
Overall, although, for smaller droplets, the probability of containing a virus copy is lower due to their initial small volume, we can observe how their large population leads to a remarkable level of virus exposure in the core region (hundreds of thousands of virions per square meter for a viral load of copies per mL,) as well as in the outer region (thousands of virions per square meter for the same viral load). As the independent action hypothesis, which states that each pathogen individual has a nonzero probability of causing host infection, seems to apply for SARS-CoV-2, the virus exposure produced by these small droplets poses a significant risk for airborne transmission. It is interesting to observe that the risk of infection via small droplets (i.e., via the airborne route) is significant in the long range (beyond from the source) but is even more important in the short range, where a remarkable level of exposure can be addressed to small droplets. This observation suggests that the airborne route has an important, if not dominant, role also in short-range transmission, and it is not limited to the long-range route, as commonly assumed in most of the current guidelines. The potential of these small droplets in causing infections in the long range is difficult to estimate, as it depends on the virus viability in the droplet nuclei (47) and on the specific environmental conditions (e.g., wind, ventilation). However, considering the relatively high density of virus copies present in these small droplets and droplet nuclei, the risk of infection via the airborne route also in the long range cannot be neglected. This risk is particularly pronounced in closed places where air dilution is low, as also documented by the large number of outbreaks that occurred in closed spaces (49–52).
Conclusions
In this study, with the help of finely time- and space-resolved experiments and simulations, we provide evidence that current guidelines, which rely on recommendations based on seminal works (12, 53), present several flaws. A first flaw is identified in the standard prediction of the evaporation times: Models currently used in public health guidelines grossly underestimate, by at least one order of magnitude, the actual evaporation times. A second flaw is represented by the threshold used to differentiate between large and small droplets; while this definition can be meaningful in healthcare environments where the term “aerosol” refers to a specific group of operations, from a fluid dynamics perspective, this criterium is questionable, as the behavior of droplets is influenced by the local flow conditions (e.g., breath/cough/sneeze), and even large droplets (, considered as ballistic in most guidelines) stay suspended in the environment for a considerable amount of time. These flaws lead to a consistent underestimation of the infection risk: Formation of droplet nuclei is delayed with respect to predictions, and droplets remain in the most infectious condition (liquid) for a much longer time. In addition, the flow conditions generated by violent expiratory events (sneeze) allow 60- to 100- droplets to remain airborne for a significant amount of time. As highlighted by the virus exposure maps, this leads to a remarkable risk of infection via airborne particles also in the short-range transmission. In light of the present findings, we believe that mitigation of the infection risk via the short-range airborne route (6, 17, 18) must be addressed in current guidelines.
Materials and Methods
We summarize here the numerical and experimental methodologies used. Further details on the numerical method, experimental setup, and additional tests can be found in SI Appendix.
Simulations.
The numerical simulations are based on a hybrid Eulerian−Lagrangian framework (54). An Eulerian large-eddy simulation approach is used to describe the velocity, density, vapor, and temperature fields, while the motion, mass, and temperature of the droplets are described using a Lagrangian approach. The computational domain consists of a horizontal cylinder into which the droplet-laden sneezing jet is injected via a circular orifice of radius that mimics the mouth opening (55). The cylinder has dimensions along the azimuthal, radial, and axial directions. A total mass of liquid equal to is ejected together with the sneezing jet. The resulting volume fraction is , in agreement with previous measurements (20, 56). The inflow velocity profile is obtained from a gamma probability distribution function (23), and the overall duration of the injection stage is about 0.6 s. The jet has a temperature of and a relative humidity equal to (20, 57, 58), while its peak velocity is (32, 59). Please note that, in the simulation used to compare numerical and experimental results, we consider a jet having the same temperature and humidity as the ambient. For the liquid phase, for each respiratory droplet, its initial diameter is assumed to follow a log-normal distribution with geometric mean equal to and geometric SD equal to 0.7 (26). The ambient is assumed quiescent and characterized by a uniform temperature and relative humidity and constant thermodynamic pressure. We consider four ambient conditions: two temperatures, and , and two relative humidities, and . To simulate the presence of nonvolatile elements such as salt, protein, and pathogens in the respiratory liquid (60), the minimum size that a droplet can attain has been limited to 3% of the initial volume (30% of the initial diameter) (25–28). Additional simulations, of which detailed discussion can be found in SI Appendix, have been also performed to test the results sensitivity to multiple sneezing events and initial droplet size distribution.
Experiments.
The experimental setup has been designed to obtain a repeatable droplet-laden jet having properties (jet duration, flow rate) analogous to those considered in the numerical simulations. To prevent exposure of human beings to the potentially harmful laser light, a dummy head is used. The flow is generated by a compressor-based system and is controlled with the aid of an electromagnetic valve. The air stream is seeded with nonevaporating, tracer-like droplets (average size 2 m, Stokes number ) and finally emitted through a circular opening (radius ) located on the front of the head. The seeding solution is kept at ambient temperature. We observed that the droplets remain suspended in the ambient for a long time, without any apparent effect of sedimentation. We performed 94 experiments, consisting of a series of seven recordings with high-speed cameras and 87 velocity measurements with hot-wire anemometry. Further experiments, not listed above, and discussed in SI Appendix, have been performed to analyze the effect of face-covering devices. All the experiments are performed in the same flow conditions (fluids temperature, jet duration, flow velocity). We use a high-speed imaging system (acquisition rate ) to record the evolution of the flow on a 4-mm-thick vertical plane. The main components of the imaging system are a double-pulse laser ( per pulse) and a high-speed camera (sensor size of 2,5601,600 pixels at ) looking perpendicularly to the laser sheet and located at a distance of from the laser plane. The droplet distribution (Fig. 1, Insets) is processed to identify the relevant flow quantities, such as the front and opening angle of the jet. Finally, we employ a hot-wire anemometry technique (acquisition rate ) to characterize the axial flow evolution; that is, we measure the time- and space-dependent flow axial velocity at different locations. These measurements are also used to verify that the flow generated is highly repeatable.
Supplementary Material
Acknowledgments
Consorzio Interuniversitario per il Calcolo Automatico (CINECA supercomputing center, Bologna, Italy) is gratefully acknowledged for generous allowance of computer resources under Grant HP10C1XSJU. We gratefully acknowledge the financial support from the Marie Skłodowska-Curie Innovative Training Networks, European Industrial Doctorates (MSCA-ITN-EID, Grant 813948), project next-generation Computational Methods for Enhanced Multiphase Flow Processes (COMETE), from Progetti di Ricerca di Interesse Nazionale (PRIN, project “Advanced computations and experiments in turbulent multiphase flow,” Grant 2017RSH3JY), and from the research project promoted by China Scholarship Council (Grant 201806250023).
Footnotes
The authors declare no competing interest.
This article is a PNAS Direct Submission.
This article contains supporting information online at https://www.pnas.org/lookup/suppl/doi:10.1073/pnas.2105279118/-/DCSupplemental.
Data Availability
Simulation results and postprocessing tools have been deposited in “Short-range exposure to airborne virus transmission and current guidelines” (https://doi.org/10.1101/2021.04.06.21255017).
The datasets analyzed in the present study have been deposited in Figshare (https://doi.org/10.6084/m9.figshare.14754096) (61).
References
- 1.Lewis D., COVID-19 rarely spreads through surfaces. So why are we still deep cleaning? Nature 590, 26–28 (2021). [DOI] [PubMed] [Google Scholar]
- 2.Goldman E., Exaggerated risk of transmission of COVID-19 by fomites. Lancet Infect. Dis. 20, 892–893 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.World Health Organization , Infection Prevention and Control of Epidemic- and Pandemic-Prone Acute Respiratory Infections in Health Care (World Health Organization, 2014). [PubMed] [Google Scholar]
- 4.Chartier Y., Pessoa-Silva C., Natural Ventilation for Infection Control in Health-Care Settings (World Health Organization, 2009). [PubMed] [Google Scholar]
- 5.Wilson N., Corbett S., Tovey E., Airborne transmission of covid-19. BMJ 370, m3206 (2020). [DOI] [PubMed] [Google Scholar]
- 6.Zhang N., et al., Close contact behavior in indoor environment and transmission of respiratory infection. Indoor Air 30, 645–661 (2020). [DOI] [PubMed] [Google Scholar]
- 7.Wei J., Li Y., Enhanced spread of expiratory droplets by turbulence in a cough jet. Build. Environ. 93, 86–96 (2015). [Google Scholar]
- 8.Editorial , COVID-19 transmission—Up in the air. Lancet Respir. Med. 2600, 30514 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Gregson F. K. A., Robinson J. F., Miles R. E. H., Royall C. P., Reid J. P., Drying kinetics of salt solution droplets: Water evaporation rates and crystallization. J. Phys. Chem. B 123, 266–276 (2019). [DOI] [PubMed] [Google Scholar]
- 10.Mittal R., Ni R., Seo J. H., The flow physics of covid-19. J. Fluid Mech. 894, F2 (2020). [Google Scholar]
- 11.Chong K. L., et al., Extended lifetime of respiratory droplets in a turbulent vapor puff and its implications on airborne disease transmission. Phys. Rev. Lett. 126, 034502 (2021). [DOI] [PubMed] [Google Scholar]
- 12.Wells W. F., On air-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20, 611–618 (1934). [Google Scholar]
- 13.Nicas M., Jones R. M., Relative contributions of four exposure pathways to influenza infection risk. Risk Anal. 29, 1292–1303 (2009). [DOI] [PubMed] [Google Scholar]
- 14.Tellier R., Li Y., Cowling B. J., Tang J. W., Recognition of aerosol transmission of infectious agents: A commentary. BMC Infect. Dis. 19, 101 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Rosti M. E., Olivieri S., Cavaiola M., Seminara A., Mazzino A., Fluid dynamics of COVID-19 airborne infection suggests urgent data for a scientific design of social distancing. Sci. Rep. 10, 22426 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Dhand R., Li J., Coughs and sneezes: Their role in transmission of respiratory viral infections, including SARS-CoV-2. Am. J. Resp. Crit. Care Med. 202, 651–659 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Liu L., Li Y., Nielsen P. V., Wei J., Jensen R. L., Short-range airborne transmission of expiratory droplets between two people. Indoor Air 27, 452–462 (2017). [DOI] [PubMed] [Google Scholar]
- 18.Chen W., Zhang N., Wei J., Yen H. L., Li Y., Short-range airborne route dominates exposure of respiratory infection during close contact. Build. Environ. 176, 106859 (2020). [Google Scholar]
- 19.Vincent J. H., Health-related aerosol measurement: A review of existing sampling criteria and proposals for new ones. J. Environ. Monit. 7, 1037–1053 (2005). [DOI] [PubMed] [Google Scholar]
- 20.Bourouiba L., Dehandschoewercker E., Bush J. W., Violent expiratory events: On coughing and sneezing. J. Fluid Mech. 745, 537–563 (2014). [Google Scholar]
- 21.Abkarian M., Mendez S., Xue N., Yang F., Stone H. A., Speech can produce jet-like transport relevant to asymptomatic spreading of virus. Proc. Natl. Acad. Sci. U.S.A. 117, 25237–25245 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Rosti M. E., Cavaiola M., Olivieri S., Seminara A., Mazzino A., Turbulence role in the fate of virus-containing droplets in violent expiratory events. Phys. Rev. Research 3, 013091 (2021). [Google Scholar]
- 23.Busco G., Yang S. R., Seo J., Hassan Y. A., Sneezing and asymptomatic virus transmission. Phys Fluids (1994) 32, 073309 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Sangras R., Kwon O., Faeth G., Self-preserving properties of unsteady round nonbuoyant turbulent starting jets and puffs in still fluids. J. Heat Transfer 124, 460–469 (2002). [Google Scholar]
- 25.Chaudhuri S., Basu S., Kabi P., Unni V. R., Saha A., Modeling the role of respiratory droplets in Covid-19 type pandemics. Phys Fluids (1994) 32, 063309 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Balachandar S., Zaleski S., Soldati A., Ahmadi G., Bourouiba L., Host-to-host airborne transmission as a multiphase flow problem for science-based social distance guidelines. Int. J. Multiph. Flow 132, 103439 (2020). [Google Scholar]
- 27.Smith S. H., et al., Aerosol persistence in relation to possible transmission of SARS-CoV-2. Phys. Fluids (1994) 32, 107108 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Stadnytskyi V., Bax C. E., Bax A., Anfinrud P., The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission. Proc. Natl. Acad. Sci. U.S.A. 117, 11875–11877 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Redrow J., Mao S., Celik I., Posada J. A., Feng Z., Modeling the evaporation and dispersion of airborne sputum droplets expelled from a human cough. Build. Environ. 46, 2042–2051 (2011). [Google Scholar]
- 30.Langmuir I., The evaporation of small spheres. Phys. Rev. 12, 368 (1918). [Google Scholar]
- 31.Ng C. S., et al., Growth of respiratory droplets in cold and humid air. Phys. Rev. Fluids 6, 054303 (2021). [Google Scholar]
- 32.Xie X., Li Y., Chwang A. T., Ho P. L., Seto W. H., How far droplets can move in indoor environments—Revisiting the Wells evaporation-falling curve. Indoor Air 17, 211–225 (2007). [DOI] [PubMed] [Google Scholar]
- 33.Nardell E. A., Transmission and institutional infection control of tuberculosis. Cold Spring Harb. Perspect. Med. 6, a018192 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Alonso C., Raynor P. C., Davies P. R., Torremorell M., Concentration, size distribution, and infectivity of airborne particles carrying swine viruses. PLoS One 10, e0135675 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Anand S., Mayya Y. S., Size distribution of virus laden droplets from expiratory ejecta of infected subjects. Sci. Rep. 10, 21174 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Pan Y., Zhang D., Yang P., Poon L. L. M., Wang Q., Viral load of SARS-CoV-2 in clinical samples. Lancet Infect. Dis. 20, 411–412 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Liu Y., et al., Viral dynamics in mild and severe cases of COVID-19. Lancet Infect. Dis. 20, 656–657 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Wölfel R., et al., Virological assessment of hospitalized patients with COVID-2019. Nature 581, 465–469 (2020). [DOI] [PubMed] [Google Scholar]
- 39.To K. K. W., et al., Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: An observational cohort study. Lancet Infect. Dis. 20, 565–574 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Rothe C., et al., Transmission of 2019-nCoV infection from an asymptomatic contact in Germany. N. Engl. J. Med. 382, 970–971 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Cevik M., Kuppalli K., Kindrachuk J., Peiris M., Virology, transmission, and pathogenesis of SARS-CoV-2. BMJ 371, m3862 (2020). [DOI] [PubMed] [Google Scholar]
- 42.Pujadas E., et al., SARS-CoV-2 viral load predicts COVID-19 mortality. Lancet Respir. Med. 8, e70 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Fajnzylber J., et al., SARS-CoV-2 viral load is associated with increased disease severity and mortality. Nat. Commun. 11, 5493 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Lavezzo E., et al., Suppression of a SARS-CoV-2 outbreak in the Italian municipality of Vo’. Nature 584, 425–429 (2020). [DOI] [PubMed] [Google Scholar]
- 45.Santarpia J. L., et al., Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care. Sci. Rep. 10, 1–8 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Ma J., et al., COVID-19 patients in earlier stages exhaled millions of SARS-CoV-2 per hour. Clin. Infect. Dis. 72, e652–e654 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.van Doremalen N., et al., Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. N. Engl. J. Med. 382, 1564–1567 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Asadi S., Bouvier N., Wexler A. S., Ristenpart W. D., The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles? Aerosol Sci. Technol. 54, 635–638 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Miller S. L., et al., Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event. Indoor Air 31, 314–323 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Lu J., et al., COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020. Emerg. Infect. Dis. 26, 1628–1631 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Shen Y., et al., Community outbreak investigation of SARS-CoV-2 transmission among bus riders in eastern China. JAMA Intern. Med. 180, 1665–1671 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Park S. Y., et al., Coronavirus disease outbreak in call center, South Korea. Emerg. Infect. Dis. 26, 1666–1670 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Duguid J. P., The size and the duration of air-carriage of respiratory droplets and droplet-nuclei. J. Hyg. (Lond.) 44, 471–479 (1946). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Wang J., Dalla Barba F., Picano F., Direct numerical simulation of an evaporating turbulent diluted jet-spray at moderate Reynolds number. Int. J. Multiph. Flow 137, 103567 (2021). [Google Scholar]
- 55.Gupta J. K., Lin C. H., Chen Q., Flow dynamics and characterization of a cough. Indoor Air 19, 517–525 (2009). [DOI] [PubMed] [Google Scholar]
- 56.Dbouk T., Drikakis D., On coughing and airborne droplet transmission to humans. Phys. Fluids (1994) 32, 053310 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Ferron G., Haider B., Kreyling W., Inhalation of salt aerosol particles—I. Estimation of the temperature and relative humidity of the air in the human upper airways. J. Aerosol Sci. 19, 343–363 (1988). [Google Scholar]
- 58.Morawska L., et al., Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. J. Aerosol Sci. 40, 256–269 (2009). [Google Scholar]
- 59.Bourouiba L., Turbulent gas clouds and respiratory pathogen emissions: Potential implications for reducing transmission of COVID-19. JAMA 323, 1837–1838 (2020). [DOI] [PubMed] [Google Scholar]
- 60.Vejerano E. P., Marr L. C., Physico-chemical characteristics of evaporating respiratory fluid droplets. J. R. Soc. Interface 15, 20170939 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Wang J. and Mobin Alipour and Giovanni Soli, Short-range exposure to airborne virus transmission and current guidelines. Figshare. https://figshare.com/articles/dataset/Short-range_exposure_to_airborne_virus_transmission_and_current_guidelines/14754096. Deposited 9 June 2021. [DOI] [PMC free article] [PubMed]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Simulation results and postprocessing tools have been deposited in “Short-range exposure to airborne virus transmission and current guidelines” (https://doi.org/10.1101/2021.04.06.21255017).
The datasets analyzed in the present study have been deposited in Figshare (https://doi.org/10.6084/m9.figshare.14754096) (61).