Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2023 Jan 1.
Published in final edited form as: Connect Tissue Res. 2021 Apr 5;63(1):16–27. doi: 10.1080/03008207.2021.1897582

Effects of osteogenic ambulatory mechanical stimulation on early stages of BMP-2 mediated bone repair

Brett S Klosterhoff 1,2, Casey E Vantucci 2,3, Jarred Kaiser 4,5, Keat Ghee Ong 6, Levi B Wood 1,2,3, Jeffrey A Weiss 7,8,9, Robert E Guldberg 6, Nick J Willett 2,3,4,5
PMCID: PMC8490484  NIHMSID: NIHMS1687448  PMID: 33820456

Abstract

Purpose:

Mechanical loading of bone defects through rehabilitation is a promising approach to stimulate repair and reduce non-union risk; however, little is known about how therapeutic mechanical stimuli modulate early stage repair before mineralized bone formation. The objective of this study was to investigate the early effects of osteogenic loading on cytokine expression and angiogenesis during the first 3 weeks of BMP-2 mediated segmental bone defect repair.

Materials and Methods:

A rat model of BMP-2 mediated bone defect repair was subjected to an osteogenic mechanical loading protocol using ambulatory rehabilitation and a compliant, load-sharing fixator with integrated implantable strain sensor. The effect of fixator load-sharing on local tissue strain, angiogenesis, and cytokine expression was evaluated.

Results:

Using sensor readings for local measurements of boundary conditions, finite element simulations showed strain became amplified in remaining soft tissue regions between 1 and 3 weeks (Week 3: load-sharing: −1.89 ± 0.35% and load-shielded: −1.38 ± 0.35% vs. Week 1: load-sharing: −1.54 ± 0.17%; load-shielded: −0.76 ± 0.06%). Multivariate analysis of cytokine arrays revealed that load-sharing significantly altered expression profiles in the defect tissue at 2 weeks compared to load-shielded defects. Specifically, loading reduced VEGF (p=0.052) and increased CXCL5 (LIX) levels. Subsequently, vascular volume in loaded defects was reduced relative to load-shielded defects but similar to intact bone at 3 weeks. Endochondral bone repair was also observed histologically in loaded defects at 3 weeks.

Conclusions:

Together, these results demonstrate that moderate ambulatory strains previously shown to stimulate bone regeneration significantly alter early angiogenic and cytokine signaling and may promote endochondral ossification.

Keywords: bone repair, rehabilitation, mechanobiology, immune response, angiogenesis word

Introduction

Bone is a dynamic tissue whose development and maintenance are heavily influenced by biomechanical stimuli exerted by load-bearing activities. After fracture, bone possesses a significant intrinsic capacity to regenerate injured tissue and restore critical biomechanical functions. However, approximately 5% of the millions of skeletal fractures that occur each year result in non-unions, where the bone defect does not heal effectively from the initial treatment and remains mechanically unstable1. The associated prolonged disability and multiple surgeries endured by such patients is a substantial healthcare burden2. Bone healing outcomes are regulated in part by the magnitude of mechanical stimulation exerted on the healing tissue during repair, where a moderate degree of mechanical stimulation can enhance bone repair, but excessive loading can result in hypertrophic non-union3,4.

Given the mechanosensitive nature of bone repair, the integration of rehabilitative exercise and natural load-bearing activity into treatment regimens is an established approach to stimulate bone repair after injury5,6. However, the majority of prior data describing therapeutic mechanical loading is predicated on relatively simple transverse fracture healing models4,7,8. There is little data that describes how vital biological mechanisms of bone repair prior to mineralization are modulated by mechanical loading in large segmental bone defects commonly treated with osteogenic factors including autologous bone graft or bone morphogenetic protein 2 (BMP-2). Consequently, mechanical loading is typically only implemented at later time points in segmental bone defect repair after mineralized bridging9.

Initially after a fracture, a diverse population of myeloid and lymphoid lineage immune cells rapidly infiltrate the injury site to clear pathogens and necrotic debris, remodel the extracellular matrix (ECM), and critically, to secrete cytokines to recruit mesenchymal and endothelial progenitors10,11. Increasing evidence has demonstrated that immune cells functionally respond to mechanical cues in a variety of disease and repair contexts12,13. Monocytes respond to fluid shear and compressive stresses by increasing production of pro-inflammatory cytokines in agarose gel cultures14. As immune cells resolve acute inflammatory signals, they secrete angiogenic cues. Effective bone regeneration is reliant on sufficient revascularization of the defect region via angiogenesis initiating from nearby vasculature15. These nascent vascular networks are also known to be mechanosensitive. Growth and alignment of microvessels in three-dimensional cultures are modulated by the application of tensile strain or dynamic compression16,17. The aforementioned in vitro results provide preliminary evidence that cytokine signaling and angiogenesis are mechanosensitive; however, in vitro systems do not recapitulate the cellular and molecular complexity of the regenerative niche in vivo. Several animal studies have demonstrated that excessive tissue loading caused by unstable bone defect fixation leads to delayed bone repair or non-union. In these impaired healing environments, there is an inhibition of angiogenic gene expression and severe abrogation of defect revascularization1820. However, the effects of osteogenic and potentially therapeutic mechanical loading regimes on the biology of early stage segmental bone repair remain poorly understood.

We have previously developed a novel implantable strain sensor platform and measured strains during rehabilitation in critically-sized rat segmental defect model treated with a minimal healing dose of BMP-221,22. We observed that controlled mechanical stimulation via early ambulatory loading 1 week after injury significantly enhanced bone regeneration22. Furthermore, we observed a significant positive correlation between strain magnitudes at 1 week with long term healing outcomes, suggesting potent magnitude-dependent effects of mechanical stimulation on early stages of bone repair. However, the underlying early-stage biological effects preceding enhanced bone formation have not been thoroughly investigated.

In this study, our overarching objective was to investigate how key aspects of the early stage regenerative response, including cytokine expression, tissue composition, and angiogenesis are modulated by the application of osteogenic mechanical strain during BMP-2 mediated bone regeneration in vivo. In prior studies using this pre-clinical rat segmental defect model, we have demonstrated that vascular volume under stable fixation peaks at 2 weeks and appreciable mineralization begins to occur at 3 weeks18,23. Thereafter, excess vessels are progressively pruned while remaining vessels mature via dilation and arteriogenesis23,24. Therefore, in this study, we selected the 2 week time point for cytokine analyses to determine the relative effect of mechanical loading at peak vascularization. The cytokine expression findings at 2 weeks prompted further investigation of previously collected data in this animal model. Specifically, we evaluated the status of vascularization at the onset of bone defect mineralization in this model: 3 weeks22. Given that prior research has demonstrated that excessive loading dramatically increases cytokine signaling19, we hypothesized that osteogenic mechanical stimulation would moderately elevate aspects of the coordinated cytokine response to support sufficient vascularization and endochondral bone repair.

Materials and Methods

Surgical procedure

All animal procedures were approved by the Georgia Institute of Technology IACUC (Protocol A17034). Two animal studies were conducted using identical injury, treatment, and rehabilitation procedures described below. The first study concluded 2 weeks post-surgery with multiplex cytokine and histological analyses of the newly formed tissue in the bone defect. The findings of the 2 week analyses prompted us to conduct new analyses utilizing mechanical strain data and tissue samples collected during a previous animal study in this model which concluded at 3 weeks with terminal microcomputed tomography (microCT) angiography. Therefore, microCT-based finite element models, histological samples, and vascular volumes from this previous study were generated and analyzed to better understand the progression of the mechanical environment as well as the tissue composition and vascular volume at the onset of mineralization in this model22.

Similar to previously described procedures, a unilateral 6 mm segmental defect was surgically created in the left femur of 15 week old female CD Sprague-Dawley rats in both studies (n=24, Charles River Labs)25. Anesthesia was maintained by isoflurane inhalation and analgesia was provided by a pre-operative subcutaneous injection of sustained-release buprenorphine. Before creating the defect with an oscillating saw, femurs were stabilized by affixing a custom-machined radiolucent internal fixator plate comprised of either polysulfone (PSU, McMaster-Carr), or ultra-high molecular weight polyethylene (UHMWPE, Quadrant) using four stainless steel screws. UHMWPE fixators were 40% more compliant than PSU (flexural stiffness: PSU = 232 ± 20 N/mm; UHMWPE = 145 ± 11 N/mm)22. Fixators in the 3 week vascularization study contained integrated wireless strain sensors that provided real-time non-invasive measurements of mechanical strain across the bone defect during ambulatory activity, as previously described21,22. The sensors transmitted wireless measurements of axial strain across the bone defect fixator in real-time during ambulation via Bluetooth. Fixators in the 2 week defect tissue cytokine analysis study were stabilized by identical fixators without the integrated strain sensors. Defects in both studies were acutely treated with a minimal healing dose of recombinant human bone morphogenetic protein 2 (BMP-2) delivered via a hybrid RGD-alginate/PCL biomaterial platform described in detail previously26. Briefly, treatment consisted of installing an electrospun polycaprolactone (PCL, Sigma-Aldrich) tube across the defect gap, then injecting 120 μL alginate hydrogel laden with 2 μg BMP-2 (Pfizer) inside the tube. Fixators were allocated randomly. After either 2 or 3 weeks, animals were anesthetized then euthanized via CO2 asphyxiation.

Treadmill walking

To exert a semi-controlled ambulatory mechanical load on the femur, animals were walked on a treadmill. Animals were trained to walk at a slow, consistent speed of 6.5 m/min 1 week prior to surgery. After surgery, animals were allowed to recover in cages for 1 week, then 10 minute walking periods were initiated at day 7 and continued twice weekly thereafter. The distance traversed during this period (65 m) roughly approximates the best available estimate of the total distance covered during one day of in-cage activity in healthy mice27.

Finite element analyses

Sample-specific finite element (FE) models of the femur-fixator constructs were constructed at 1 and 3 weeks using similar methods described previously22. Briefly, microCT images were processed in MIMICS (Materialise) to create a representative model of proximal and distal femur segments with the fixator attached. At 1 week, defects were assumed to be a homogeneous 5 mm diameter cylinder comprised of soft tissue. For 3 week models, pre-decalcification microCT geometry of mineralized woven bone (threshold = 388 mg HA/ccm) were included within the soft tissue cylinder of each femur sample. Volumetric meshes of quadratic tetrahedral elements were constructed. Mesh resolution convergence was previously demonstrated at approximately 1.5x106 equations22. All materials were constitutively modelled as neo-hookean solids and previously reported experimentally validated mechanical properties were assigned (Table S1)22,28.

In each model, animal-specific boundary conditions were defined based on axial strain measurements by the wireless strain sensor at the corresponding 1 or 3 week treadmill period. Similar to previously reported simulations, boundary conditions were applied to replicate in vivo loading29; the distal end of the femur was fixed in all directions and combined axial compression and bending pressures were applied to the proximal surface. All FE simulations were conducted in FEBio (version 2.8.5) and results were evaluated in PostView30. To capture inter-animal variability of the complete data set while maintaining computational efficiency, a sub-set of animals (n=5 from each fixator group) were evaluated by longitudinal FE analyses at both 1 and 3 weeks, creating 20 FE simulations in total. The distribution of strain magnitude and woven bone volume were identical between the sub-set of animals and the complete experimental group, confirming that the sub-set was an accurate depiction of the full data set (Fig. S1).

Analyses of defect tissue cytokines

In the 2-week study, animals were euthanized 24 hours after the final week 2 treadmill period. Defect tissue inside and adhered to the outside of the PCL tube was immediately and carefully harvested. Upon dissection, two samples were excluded from analysis due to evidence of tissue abscess near the fixator indicative of infection. Individual tissue samples were flash frozen in liquid nitrogen and then stored at −80⁰ C for subsequent Luminex multiplexed immunoassays. Samples were thawed and homogenized in RIPA lysis buffer (Thermo Fisher) supplemented with 1X Halt protease inhibitor cocktail (Thermo Fisher). Lysates were centrifuged at 13,000 g for 15 minutes and supernatants were transferred to new tubes and stored at −80⁰ C. A panel of 27 cytokines were quantified using a Milliplex MAP Rat Cyotkine/Chemokine Magnetic Bead Panel according to the manufacturer’s instructions and then read using a MAGPIX instrument (Luminex). Cytokine concentration was normalized to total protein content quantified using a bicinchoninic acid assay (BCA assay, Thermo Fisher). The final sample sizes for each group were: UHMWPE = 9 and PSU = 11.

Histology

Representative femur samples from each study end point, at weeks 2 and 3 respectively, were reserved for histological analysis based on digital radiographs acquired immediately before euthanasia. Femora were fixed in 10% neutral-buffered formalin for 48 hrs at 4 °C and switched to PBS after. HistoTox Labs completed decalcification, paraffin processing, and staining. Midsagittal 5 µm thick sections were stained with Hematoxylin & Eosin (H&E), Safranin-O/Fast Green, or Picro Sirius Red.

MicroCT angiography

Vascular volume within and around the segmental bone defect in the 3 week animal study was quantified using microcomputed tomography (microCT) angiography. Unoperated contralateral femora were also harvested and evaluated for angiography analyses to obtain a benchmark quantification of vascularization in intact bone. Briefly, vasculature was perfused successively with 0.9% saline, 0.4% papaverine hydrochloride vasodilator, 0.9% saline, 10% neutral buffered formalin (NBF), 0.9% saline, and radiopaque contrast agent31 (2:1; Microfil MV-22, FlowTech Inc.), then allowed to polymerize at 4° C overnight. Dissected femora were scanned using microCT with 15 μm voxels, 55 kVp, 145 μA, and 300 ms integration time. Samples were then decalcified for 10 days under light agitation in a mixture of formic acid and citrate (Newcomers Supply) changed daily. Samples were then scanned with microCT a second time. Vascular volume was quantified within 3 different 4.14 mm long cylindrical volumes of interest (VOI’s): (1) the “Defect VOI” – a 5 mm diameter cylinder within the PCL mesh tube spanning the defect; (2) the “Total VOI” – a 7 mm diameter cylinder encompassing the Defect VOI and including surrounding vasculature adjacent to the PCL mesh; and (3) the “Surrounding VOI” - the annulus created by subtracting the Defect VOI from the Total VOI.

Statistical analyses

Data are displayed as mean ± standard error of the mean or as box plots showing 25th and 75th percentiles, with whiskers extending to minimum and maximum values, unless otherwise noted in the figure heading. Differences were assessed using t-test. Welch’s t-test or Mann-Whitney U test and Kruskal-Wallis test was used in cases of unequal variances or non-normal distributions, respectively. Two-way ANOVA with Tukey’s or Sidak’s pairwise comparisons were used to compare groups for longitudinal FE analyses. Significance was determined using p < 0.05. Statistical tests were performed by GraphPad Prism 8.

Univariate and multivariate analysis of cytokine expression profiles within the defect were conducted to evaluate differences between fixator stiffness groups, as described previously32. Briefly, univariate t-tests were performed comparing the normalized median fluorescence intensity values of individual cytokines. Discriminant partial least squares regression (D-PLSR) was performed using the PLS MATLAB (Mathworks) algorithm developed by Cleiton Nunes (Mathworks File Exchange). Individual cytokine measurements were used as independent variables, and fixator stiffness was used as the discrete regression variable. Multi-dimensional latent variables (LV’s) were defined in three dimensions, and an orthogonal rotation was implemented to assess separation by fixator stiffness in the LV1-LV2 plane. Standard deviation of the contribution of each cytokine to LV1 were computed using leave-one-out cross validation without replacement.

Results

Local defect tissue strain increased over time to soft tissue regions as mineralization initiated

Specimen-specific longitudinal FE analyses revealed 3rd principal strain magnitude (the maximum local compressive strain) in non-mineralized soft tissue during gait within defects stabilized by either stiff PSU fixation or compliant, load-sharing UHMWPE fixation at 1 week (Fig. 1 & Fig. 2A & B; UHMWPE: −1.54 ± 0.17%; PSU: −0.76 ± 0.06%, p = 0.077). Between 1 and 3 weeks, woven bone extending from the intact bone ends was formed within the defects. The deposition of relatively stiff woven bone reduced the proportion of soft tissue within the defect. Consequently, the magnitude of 3rd principal strain within soft tissue increased between weeks 1 and 3 (Fig. 2A & C Wk 3: UHMWPE: −1.89 ± 0.35%; PSU: −1.38 ± 0.35%, *p = 0.04 Wk 1 vs. 3). As indicated by representative FE model cross-sections, the magnitude of strain was relatively heterogeneous throughout the defect, reaching maxima of 3-6% in some regions under load-sharing fixation at 1 week and increasing to 5-10% in both fixation groups at 3 weeks (Fig. 1 & Fig. 2B & C). In newly formed woven bone, mean 3rd principal strain magnitude was similar regardless of fixator stiffness (Fig. 2D & E; UHMWPE: −0.47 ± 0.08%; PSU: −0.55 ± 0.12%, n/s). The resultant axial load at the proximal femur during gait averaged 3.78 ± 0.35 bodyweight (BW) overall (Fig. 2F). Axial load did not change between 1 and 3 weeks and was not affected by fixation stiffness. Axial loads had high variance from animal to animal (Min: 0.87 BW; Max: 7.2 BW), and there was a significant effect of animal over time (p < 0.05), suggesting heterogeneity in hindlimb utilization on a per animal basis as each animal recovered from surgery.

Figure 1.

Figure 1.

Representative image-based finite element model cross-sections demonstrate elevated strain magnitudes within UHMWPE-stabilized defects at 1 week. Regions of elevated strain localized to non-mineralized soft tissue regions at 3 weeks.

Figure 2.

Figure 2.

(A) Mean 3rd principal strain of non-mineralized soft tissue within the defect increased between 1 and 3 weeks due to the increased proportion of much stiffer woven bone as healing progressed. n=5. *p<0.05 Wk 1 vs. 3, #p=0.077 UHMWPE vs. PSU via Two-way RM ANOVA. Soft tissue strain distribution throughout the defect within each of 5 experimental samples was spatially heterogeneous at (B) 1 and (C) 3 weeks. In all box plots, the mean is denoted by a dot and whiskers are defined using the Tukey method. (D) Mean 3rd principal strain magnitude within immature woven bone at 3 weeks averaged approximately 0.5% regardless of fixator stiffness. n=5. n/s via t-test. (E) Woven bone tissue strain was similarly heterogeneous throughout the defect in each experimental sample. (F) Peak femoral loads were variable between animals, averaging approximately four-fold body weight (BW) regardless of fixator stiffness or time point. n=5. n/s via Two-way RM ANOVA.

Load sharing altered cytokine expression profile within bone defects at 2 weeks

Defect tissue lysate was analyzed for an array of cytokines. To distinguish multivariate cytokine expression profiles differentially regulated by defect tissue strain, discriminant partial least squares regression (D-PLSR) was performed33. D-PLSR revealed that fixation plate stiffness groups primarily separated along the LV1 axis (Fig. 3A). Defect samples stabilized by stiffer, load-shielding PSU fixators scored significantly higher along LV1 relative to samples stabilized by more compliant, load-sharing UHMWPE fixators (Fig. 3B). The LV1 axis represents a combination of cytokines that have been reduced in dimensionality in order to maximally separate the data based on fixator stiffness. Based on the LV1 loading plot, we can determine which cytokines most contributed to positive and negative LV1 scores, which were associated with load-shielding and load-sharing fixation, respectively (Fig. 3C). VEGF and IL-4 were associated with load-shielding along LV1, whereas expression of LIX (CXCL5), IL-1β, and RANTES (CCL5) was associated with load-sharing fixation along LV1 (Fig. 4). Univariate pairwise comparisons showed that LIX (CXCL5) levels were significantly elevated by load-sharing fixation. Conversely, VEGF expression was elevated by load-shielding fixation (p=0.052).

Figure 3.

Figure 3.

Discriminant partial least squares regression (D-PLSR) analysis of the expression of 16 cytokines in the defect tissue at 2 weeks. (A) Latent variable 1 (LV1) defines a multivariate cytokine expression profile depicted along the x-axis that separates defects stabilized by load-shielding PSU fixators to the right and load-sharing UHMWPE fixators to the left. (B) Mean LV1 score was significantly upregulated by load-shielding PSU fixation. n=9-11. ***p<0.001 via t-test. (C) Values along LV1 describe individual cytokines with elevated expression for UHMWPE fixation (negative values) or PSU (positive values). Error bars were computed using leave-one-out cross validation (mean ± SD).

Figure 4.

Figure 4.

Univariate comparisons of individual cytokine expression in defect tissue at 2 weeks. LIX (CXCL5) expression was significantly increased by increased load sharing with load-sharing UHMWPE fixation. Conversely, VEGF expression was elevated with by load shielding with load-shielding PSU fixation. Significant pairwise differences were not observed in the remaining cytokines. n=9-11. **p<0.01 via t-test.

Vascular volume within the defect was increased at 3 weeks by load-shielding PSU fixation

MicroCT angiography revealed that vascular volume within the defect was significantly increased under stiffer, load-shielding PSU fixation at 3 weeks relative to compliant, load-sharing UHMWPE fixation or unoperated contralateral femora (Fig. 5A). The vascular volume in defects stabilized by UHMWPE was similar to the contralateral. Changes in vascular volume mediated by fixation plate stiffness were only present within the central defect; there were no differences between PSU and UHMWPE fixators in the total analyzed volume or in the surrounding tissue alone (Fig. 5B & C). Regardless of fixator stiffness, vascular volume surrounding the bone defects was significantly increased relative to unoperated femora (Fig. 5C).

Figure 5.

Figure 5.

MicroCT angiography quantification of vascular volume at 3 weeks in and surrounding the bone defects. (A) Vascular volume within the central 5 mm of the defect is increased under load-shielding fixation, though load-sharing fixation remained similar to the intact femora. n=6-10. *p<0.05 via Kruskal-Wallis test with Dunn’s pairwise comparisons (B) Vascular volume throughout the defect and surrounding tissue was elevated in injured femora relative to naïve, irrespective of fixation stiffness. n=6-10. *p<0.05 via ANOVA with Tukey’s test. (C) In the surrounding tissue alone, vascular volume was similarly elevated in injured hindlimbs regardless of fixator. n=6-10. *p<0.05 via ANOVA with Tukey’s test.

Load sharing promoted endochondral woven bone formation at 3 weeks

Qualitative histological analysis of defect tissue samples at 2 and 3 weeks revealed that marked changes in tissue composition occur during this relatively brief interval (Fig. 6). At 2 weeks, the defect was predominantly comprised of alginate hydrogel from the BMP-2 delivery vehicle. Irrespective of fixation stiffness, the presence of alginate declined between weeks 2 and 3, while qualitative increases in mineralized tissue were simultaneously apparent. Hypertrophic chondrocytes were evident at 3 weeks throughout defects stabilized by load-sharing UHMWPE but not in stiffer PSU, suggesting the initiation of endochondral ossification due to mechanical load sharing. Picro Sirius red staining viewed under polarized light revealed large red collagen fibers adjacent to regions of hypertrophic chondrocytes with UHMWPE, indicative of woven bone formation. Collagen in PSU-stabilized samples appeared primarily orange-yellow in color and qualitatively smaller in size. Lamellar collagen architecture was not observed in either group at these relatively early time points.

Figure 6.

Figure 6.

Bone defect histology at 2 and 3 weeks, including Hematoxylin & Eosin (left column for PSU and UHMWPE, except for bottom image), Safranin0O/Fast Green (right columns), and Picro Sirius red (bottom image in left columns), n=1 femur per group. Alginate hydrogel remnants are denoted as “Al”, bone is denoted as “B”, chondrocytes are denoted as “Ch”, and blood vessels are indicated with arrows extending from “V”. Dotted lines at sides of images denote intact diaphyseal bone stumps. Insets are registered to full defects by color-coded dotted rectangles. Black scale bar = 500 μm. White scale bar = 50 μm.

Discussion

Controlled mechanical loading of bone defects is a potentially potent therapeutic approach to stimulate bone repair and reduce non-union risk, but the effects of stimulatory mechanical loading on the early stages of bone repair not well understood. In particular, mechanical loading may enhance bone repair in clinically challenging defects including segmental defects created surgically after the resection of tumors, debrided comminuted traumatic fractures, or spinal fusions and corpectomies; all of which are generally treated with bone grafting or BMP-2 to supplement osteogenic capacity. The osteogenic effects of mechanical loading on bone repair after defects have been bridged with immature mineralized tissue are well described24,34. However, there is little data characterizing how potentially beneficial biophysical stimuli modulate the early stages of tissue repair after skeletal injury and before mineralized tissue is formed. Increasing evidence has demonstrated the fundamental role of the cytokine response in coordinating cell recruitment and angiogenesis preceding mineralization, and in vitro studies support that immune mediators alter cytokine secretion in response to mechanical stimuli12,13,35. Elucidating the interplay between biophysical stimulation and early stage bone repair is critical to gain a mechanistic understanding of how best to employ mechanical therapies to benefit patients at elevated risk of non-union.

In a previous study we developed a bone defect mechanical loading regimen consisting of biweekly ambulation and a load-sharing internal fixator instrumented with a wireless strain sensor; the increased mechanical stimulation permitted by the load-sharing fixator enhanced bone regeneration by 60% and nearly tripled the percent of bridged defects relative to a stiffer, load-shielding fixator. In this study, we probed how this osteogenic mechanical loading regimen altered the early stage molecular and tissue progression of bone defects. To characterize the spatiotemporal progression of this osteogenic mechanical environment in vivo, FE simulations of bone defects at 1 and 3 weeks were constructed using experimental in vivo strain measurements as boundary conditions. Compressive strain magnitudes in the non-mineralized defect soft tissue under more compliant, load-sharing fixation averaged 1.5% and 1.9% at 1 and 3 weeks respectively. As deposition of comparatively stiff woven bone was initiated, the strain magnitude within non-mineralized tissue in the defect increased between 1 and 3 weeks as deformation localized to remaining soft tissue regions. Spatial heterogeneity in deformation was apparent at both 1 and 3 weeks, though soft tissue regions with locally elevated strain magnitudes remained below 10-15% strain—a biomechanical threshold previously implicated to cause fibrosis and hypertrophic non-union4,36. A limitation of the 3-week finite element models was that blood vessels perfused with radiopaque contrast agent could not be distinguished from woven bone on microCT, though vascular volume represented a small proportion of the thresholded tissue volume, less than 7%, compared to bone. FE simulations also revealed that animals exerted an axial load at the proximal femur of approximately 4-fold bodyweight during rehabilitative treadmill walking sessions which was unaffected by fixation stiffness or time. Considering the bone injury and iatrogenic effects of the surgery, these results are comparable to an inverse dynamics analysis by Wehner and colleagues that estimated that the peak axial load through the proximal femur in an uninjured rat was 6-fold bodyweight29.

Changes in the tissue-level mechanical environment imparted by compliant, load-sharing fixation altered early stage cytokine expression. Multiplex cytokine analysis revealed that VEGF levels in the defect tissue lysate at 2 weeks were downregulated by compliant fixation. Previous studies have shown reduced VEGF mRNA expression observed at 4, 7, and 21 days in a highly unstable sheep osteotomy model that delayed bone repair20—though a clear difference being that VEGF levels still reached a sufficient level for bone repair in the study we present here. These data suggest that exogenously delivered BMP in a load shielded environment may induce VEGF exceeding the necessary levels, while unstable fixation may attenuate VEGF levels below the necessary threshold for bone healing. In addition to VEGF, expression profiles of immune cytokines and chemokines were also differentially regulated by mechanical load sharing. Multivariate expression profile analysis indicated LIX (CXCL5), IL-1β, and RANTES (CCL5), cytokines that exert diverse effects on angiogenesis, inflammation, and cell differentiation, and tissue repair, were positively associated with mechanical loading. LIX (CXCL5) expression has been shown to enhance angiogenesis, inhibit osteoclastogenesis, and can be secreted by mesenchymal progenitors via non-canonical WNT signaling as well as by macrophages3740. IL-1β is classically defined as a pro-inflammatory mediator after tissue injury41. However, even after the resolution of acute inflammation, IL-1β signaling has also been shown to play subtle roles stimulating various phases of tissue regeneration, including VEGF production, endochondral ossification, and bone remodeling4246. Similarly, RANTES (CCL5) can promote VEGF production and angiogenesis and osteogenic differentiation of mesenchymal stem cells40,47,48. There is little comparative data describing the acute cytokine response to osteogenic mechanical loading in vivo. Excessive mechanical loading designed to impair healing in a mechanically unstable sheep osteotomy model resulted in elevated cytotoxic T cells and reduced expression of the endothelial cell marker von Willebrand factor (vWF) 60 hours after surgery compared to stable fixation19. Pro-inflammatory cytokine production has also been reported in monocytes subjected to shear and compression in three-dimensional cultures. Taken together, these data suggest that mechanical loading may exert magnitude dependent effects on angiogenic and inflammatory signaling, which at low compressive magnitudes (<7%) prior to mineralization may bolster tissue repair, but at excessive magnitudes (>10%) may severely inhibit angiogenesis and impair healing22. However, the single time point of analysis and dynamic nature of cytokine production limit definitive conclusions on the overall time course of angiogenic and inflammatory signal production.

Vascular infiltration into the defect at 3 weeks was also significantly altered by dynamic load sharing. Supporting increased levels of VEGF in the defect tissue lysate at 2 weeks under stiffer, load-shielding fixation, reduced strain led to elevated vascular volume in the defect at 3 weeks. However, elevated mechanical load sharing imparted by UHMWPE fixation still supported similar vascular volume to intact femora. In response to injury, angiogenic sprouting typically produces excess nascent vessels that exceed physiological demands initially, and insufficiently matured or surplus vessels are subsequently trimmed49. Prior angiography studies in the rat femoral segmental defect model demonstrated that vascular volume with load-shielded PSU fixation peaks at 2 weeks; thereafter, excess vessels are progressively pruned while remaining vessels mature via dilation and arteriogenesis23,24. Therefore, the 3-week time point was selected to capture the status of vascularization after the pruning and maturation process begins and the onset of mineralization in the defect. Given the single 3-week measurement of vascularization, a limitation of this study is that it cannot be explicitly determined if increased load sharing permitted by load-sharing UHMWPE fixation reduced or delayed angiogenic sprouting, or accelerated pruning. Regardless, vascular volume with load-sharing fixation was similar to intact bone, suggesting that a window of sufficient vascularization had been achieved. One plausible interpretation of these data is that while vascular volume was similar to intact femora, oxygen tension in mechanically loaded defects may still have been sufficiently low compared to load-shielded defects to enhance chondrogenesis and subsequent endochondral bone repair. In vivo measures of oxygen tension in a future study would help to elucidate the role of differential vascularization on subsequent bone repair observed in this mechanical loading model.

Though limited histological tissue samples limited analysis to qualitative observation, consistent with prior reports, load sharing permitted by compliant fixation in the presence of BMP-2 supported endochondral ossification at 3 weeks, whereas intramembranous ossification was predominant with stiffer, load-shielding fixation24,50. We previously observed the presence of hypertrophic chondrocytes in this mechanical loading model at 8 weeks, at which point there was a significant 60% increase in bone formation over load-shielding fixation22. Together, these findings support that BMP-2 mediated skeletal repair can proceed via either intramembranous or endochondral ossification, and that the biomechanical conditions can dictate this switch. Overall, the data indicate there is a biomechanical threshold where vascularization begins to be reduced or delayed slightly while bone repair is simultaneously improved, primarily via endochondral repair. Prior work using significantly more compliant fixation systems have demonstrated that further increases in local tissue strain exceeding 10-15% dramatically inhibits both angiogenesis and osteogenesis4,24. Therefore, the biomechanical environment produced by rehabilitative or mechanical therapies must be carefully monitored to be safe and efficacious.

The cytokine response is critical to coordinate angiogenesis and skeletal repair after injury. The data presented here suggest that cytokine signaling processes coordinating bone repair are mechanosensitive and that key cytokines are differentially expressed when subjected to osteogenic mechanical loading produced by rehabilitative activity. The findings of this study motivate further research to determine the downstream effects of mechanosensitive perturbations in cytokine signaling on specific progenitor cell sub-populations that mediate osteogenesis.

Supplementary Material

Figure S1
Supp 1

Acknowledgements

The authors gratefully acknowledge assistance and expertise provided by members of the Guldberg and Willett labs during surgeries, the core facilities at the Parker H. Petit Institute for Bioengineering and Bioscience, and the Georgia Tech Physiological Research Lab. We also gratefully acknowledge Dr. Johnna Temenoff for permitting access to the rodent treadmill, and Dr. Scott Hollister for access to image processing software.

Funding

Funding for this work was provided by grants from the National Institutes of Health (NIH R21 AR066322; NIH R01 AR069297) and the National Science Foundation (NSF CMMI-1400065). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health or National Science Foundation. This work also received support from VA (Merit) Grant RX001985 from the United States (U.S.) Department of Veterans Affairs Rehabilitation Research and Development Service. The contents do not represent the views of the U.S. Department of Veterans Affairs or the United States Government. B.S.K. received support from the Cell and Tissue Engineering NIH Biotechnology Training Grant (T32-GM008433) and the National Science Foundation Graduate Research Fellowship Program (DGE-1650044). C.E.V. received support from the National Science Foundation Graduate Research Fellowship Program (DGE-1650044).

Footnotes

Declaration of Interests

The authors declare no competing interests.

References

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Figure S1
Supp 1

RESOURCES