Abstract
Objective
We examined the impact of simulated Tokyo 2020 environmental condition on exercise performance, thermoregulatory responses and thermal perception among Dutch elite athletes.
Methods
105 elite athletes from different sport disciplines performed two exercise tests in simulated control (15.9 ± 1.2 °C, relative humidity (RH) 55 ± 6%) and Tokyo (31.6 ± 1.0 °C, RH 74 ± 5%) environmental conditions. Exercise tests consisted of a 20-min warm-up (70% HRmax), followed by an incremental phase until volitional exhaustion (5% workload increase every 3 min). Gastrointestinal temperature (Tgi), heart rate, exercise performance and thermal perception were measured.
Results
Time to exhaustion was 16 ± 8 min shorter in the Tokyo versus the control condition (− 26 ± 11%, whereas peak power output decreased with 0.5 ± 0.3 W/kg (16 ± 7%). Greater exercise-induced increases in Tgi (1.8 ± 0.6 °C vs. 1.5 ± 0.5 °C, p < 0.001) and higher peak Tgi (38.9 ± 0.6 °C vs. 38.7 ± 0.4 °C, p < 0.001) were found in the Tokyo versus control condition. Large interindividual variations in exercise-induced increase in Tgi (range 0.7–3.5 °C) and peak Tgi (range 37.6–40.4 °C) were found in the Tokyo condition, with greater Tgi responses in endurance versus mixed- and skill-trained athletes. Peak thermal sensation and thermal comfort scores deteriorated in the Tokyo condition, with aggravated responses for power versus endurance- and mixed-trained athletes.
Conclusion
Large performance losses and Tgi increases were found among elite athletes exercising in simulated Tokyo conditions, with a substantial interindividual variation and significantly different responses across sport disciplines. These findings highlight the importance of an individual approach to optimally prepare athletes for safe and maximal exercise performance during the Tokyo Olympics.
Supplementary Information
The online version contains supplementary material available at 10.1007/s40279-021-01530-w.
Key Points
Tokyo’s climate has a major impact on the exercise capacity of non-acclimatized elite athletes, independent of sports discipline |
A large interindividual variability was found for exercise capacity and thermoregulatory responses, whereas no significant association was found between peak core temperature and performance outcomes |
Findings from this study emphasize that it is impossible to offer a ‘one-size-fits-all’ heat mitigation strategy to elite athletes, and underline the importance of determining the individual’s needs for heat acclimatization, cooling interventions and a hydration plan |
Introduction
The 2020 Summer Olympics will be held amidst Tokyo’s summer, characterised by hot [ambient air temperature (Tambient) > 30 °C] and humid [relative humidity (RH) ± 70%] environmental conditions, presumably resulting in the most challenging environmental conditions ever observed during the Olympic (Summer) Games [1, 2]. The combination of environmental heat stress and exercise-induced heat production is likely to exceed the body’s heat-dissipating capabilities [3, 4], resulting in profound core temperature elevations [4–6]. Exercise-induced core temperature elevations may cause substantial reductions in exercise performance [7, 8], and place athletes at risk of developing heat-related illnesses such as heat exhaustion and heat stroke [4, 9, 10].
Previous field studies showed considerable heterogeneity in exercise-induced thermoregulatory responses across athletes [6, 11, 12], but smaller within-participant variations [13]. These findings suggest that thermoregulatory responses during exercise in the heat might be individually determined. Indeed, a pilot study among Olympic sailors reported that some athletes were particularly prone to large performance losses but others to a high end-exercise core temperature [14]. Heat acclimatization and cooling strategies are effective countermeasures to optimize exercise performance in the heat and to minimize the risk of heat-related illnesses [15–17]. However, recommendations are often based on a one-size-fits-all approach, while the needs of an individual athlete for heat mitigation strategies may differ substantially based on their physiological responses to heat stress [18]. Identification of elite athletes with a low heat tolerance is, therefore, of utmost importance to allow timely interventions (i.e., heat acclimatization and cooling strategies) prior to Tokyo 2020 [18].
The aim of the Thermo Tokyo study was to examine the impact of the Tokyo environmental conditions on exercise performance and thermoregulatory responses in non-acclimatized elite athletes. We were specifically interested in the quantification of interindividual variations and differences in physiological and perceptual responses across sport disciplines (skill, power, mixed and endurance), as anthropometric (i.e. body fat and surface to mass ratio) and physiological (i.e. VO2max, peak power output) parameters are known to influence individual responses to heat stress [19] and may differ across sport disciplines [20]. Although observational field studies have a high external validity, such a study design hinders the assessment of heat stress-induced performance loss and prevents a direct comparison across different sport disciplines and different ambient conditions due to a low internal validity. Therefore, we performed a controlled exercise protocol in simulated Tokyo 2020 environmental conditions in the climate chamber of the Dutch Olympic Training Centre.
Methods
Participants
Dutch elite athletes were recruited via TeamNL (the Olympic division of all Dutch sports federations) infrastructures (i.e. via national sports federations, coaches, embedded scientists). Elite athletes ≥ 16 years old and practicing an outdoor sport discipline on an international level were eligible to participate in our study. Exclusion criteria were based on the use of the ingestible temperature capsule: (i) a bodyweight < 36.5 kg, (ii) an implanted electro-medical device, (iii) a history of obstructive/inflammatory bowel disease or surgery, or (iv) a scheduled MRI scan within 5 days of the experiment. Based on the relative isometric and isotonic components of exercise training, participants were classified as endurance, mixed, power or skill athletes (Table 1) [21]. The study was carried out in accordance with the Declaration of Helsinki and was approved by the Medical Ethical Committee of the Radboud University Medical Centre (#2018-4640). All participants gave their written informed consent prior to the testing procedures.
Table 1.
Endurance-trained athletes (N = 27) | Mixed-trained athletes (N = 31) | Power-trained athletes (N = 12) | Skill-trained athletes (N = 35) | p value | All athletes (N = 105) | |
---|---|---|---|---|---|---|
Age, years | 25 ± 6 | 27 ± 4c | 23 ± 3b | 25 ± 5 | 0.029* | 26 ± 5 |
Sex, n (% male) | 12 (44) | 22 (71)d | 7 (58) | 11 (31)b | 0.011* | 52 (50) |
Height, cm | 176 ± 10b | 187 ± 13a,c,d | 176 ± 8b | 177 ± 10b | < 0.001* | 180 ± 12 |
Weight, kg | 65.5 ± 9.4b,c,d | 81.3 ± 13.2a | 78.6 ± 10.0a | 78.9 ± 14.7a | < 0.001* | 76.1 ± 13.9 |
BMI, kg/m2 | 20.9 ± 1.4b,c,d | 23.1 ± 1.5a,c,d | 25.4 ± 1.3a,b | 24.9 ± 3.0a,b | < 0.001* | 23.4 ± 2.7 |
BSA, m2 | 1.81 ± 0.18b,d | 2.07 ± 0.24a | 1.95 ± 0.17 | 1.96 ± 0.22a | < 0.001* | 1.95 ± 0.23 |
Sport disciplines | Mountain biking n = 5, open water swimming n = 2, road cycling n = 7, triathlon n = 13 | 3 x 3 basketball n = 7, beach volleyball n = 8, field hockey n = 15, soccer n = 1 | BMX n = 12 |
Baseball n = 11 Sailing n = 3 Skateboarding n = 1 Softball n = 20 |
Data are presented as mean ± SD or n (%)
BMI body mass index, BSA body surface area
*p < 0.05. Significantly different from (a) endurance-trained athletes, (b) mixed-trained athletes, (c) power-trained athletes, (d) skill-trained athletes
Design
The current study is part of the Thermo Tokyo research project, the rationale and design of which have been described previously [22]. In short, athletes were invited to complete two personalised incremental exercise tests on a cycling ergometer (Lode ergometer, Lode B.V., Groningen, the Netherlands, or Tacx Neo Smart T2800, Tacx B.V., Wassenaar, the Netherlands) in a climate chamber until volitional exhaustion. Exercise tests were conducted in control (Tambient 15.9 ± 1.2 °C, RH 55 ± 6%, ambient vapour pressure 0.99 kPa, absolute humidity 0.0075 kg/m3) and Tokyo (Tambient 31.6 °C ± 1.0, RH 74 ± 5%, ambient vapour pressure 3.45 kPa, absolute humidity 0.0245 kg/m3) environmental conditions. The first exercise test was always conducted in the control condition and an ambient temperature of 15 °C was used to simulate the average ambient temperature during the summer months in the Netherlands. The personalised exercise protocol (i.e. changes in workload over time) obtained during the control condition was subsequently applied to the second exercise test in simulated Tokyo conditions. Through this, the difference between the Tokyo and control condition demonstrates the impact of the Tokyo environment on exercise performance and thermoregulatory responses compared to Dutch reference standards in non-acclimatized athletes. Study visits were separated by > 48 h, and in preparation for each visit, participants were instructed to refrain from strenuous exercise (24 h) and consumption of alcohol or caffeine (12 h). Furthermore, all participants were instructed to eat the same diet from the moment of awakening onwards and to wear the same clothes for both exercise tests, consume their last meal ≥ 3 h preceding the measurements, and consume 500 mL of water ∼ 2 h before arriving at the laboratory. Study visits commenced at the same time of day to avoid any circadian rhythm effects [23]. Participants ingested a gastrointestinal temperature capsule (myTemp, Nijmegen, the Netherlands) ~ 3 h prior to both study visits and were not allowed to drink during the exercise protocol to avoid any interaction with fluid intake [24].
Personalised Exercise Test Protocol
After the participant entered the climate chamber, the bike ergometer was fitted to the participant by adjusting the height, inclination and position of the saddle, and the height and inclination of the handlebar. If a Tacx device was used, the participant’s bike was installed before entering the climate chamber. The ergometer type and settings were the same for both tests. Then, while seated on the ergometer, the 5-min seated rest period was applied and baseline values were obtained during the last minute. Thereafter, athletes started the warm-up phase by exercising at 100 W and were instructed to maintain a pedalling speed of 80–100 revolutions per minute throughout the whole protocol. On the 3-min mark, the initial workload (in W) was gradually adjusted to reach 70% of the individual athlete's maximal heart rate (HR), which was obtained from training data or a previously performed maximal exercise test. Workload adjustments (in W) were performed on the minute marks and repeated (if necessary) until a stable target HR (i.e. 70% HRmax) was reached. Then, the workload was kept equal for the remaining minutes of the 20-min warm-up phase. At the 20-min mark, the incremental phase started and the workload (in W) was increased every 3 min by 5% of the workload corresponding to 70% HRmax. The incremental phase lasted until volitional exhaustion was reached. After exercise cessation, participants had a 3-min active cool-down at a self-selected wattage, followed by a 10-min seated rest. A protocol overview is presented in Supplementary Fig. 1 (OSM) and an example of a personalised protocol is presented in Supplementary Table 1 (OSM).
Measurements
Exercise Performance
Time to exhaustion (TTE) was measured from the start of the warm-up until volitional exhaustion and was expressed in minutes rounded to the nearest integer. Peak power output (PPO) was expressed as an absolute (W) and normalized value (W/kg), and was calculated using the following formula:
Changes in TTE (min) and PPO (W and W/kg) in the Tokyo condition relative to the control condition were calculated using the following formula:
Gastrointestinal Temperature (Tgi)
We used a validated ingestible telemetric temperature capsule system (myTemp, Nijmegen, the Netherlands) [25, 26] to continuously measure Tgi (in °C) at predefined 10-s intervals. The calibration of the myTemp ingestible temperature capsules was performed by the manufacturer (myTemp, Nijmegen, the Netherlands) as additional calibration prior to use has been demonstrated to be unnecessary [25].
Skin Temperature (Tsk)
Wireless temperature recorders (iButton DS1922L, Dallas Semiconductor Corp, USA) were attached to the skin at four distinct locations (i.e. neck, left hand, right shoulder, right shin) [27] using sweat proof Tegaderm Film (Tegaderm, Neuss, Germany) to determine Tsk. Resolution was set at 0.0625 °C and data were continuously collected at 20-s intervals. Weighted averages were calculated according to international standard operations (ISO-9886) [27].
Heart Rate (HR)
HR was measured using a Polar system (Polar V800, Polar Electro Oy, Kempele, Finland) using 1-s intervals.
Whole Body Sweat Rate (WBSR)
Participants’ bodyweight was measured to the nearest 100 g using an electronic weighting scale (Seca robusta 813 scale, Hamburg, Germany) at baseline and directly after finishing the experimental protocol to determine WBSR. Bodyweight measurements were performed in shorts and underwear and the assessment of WBSR did not contain any fluid intake or urine excretion. Dehydration was defined as a bodyweight loss of > 2% [28].
Subjective Measures
Thermal comfort, thermal sensation and rating of perceived exertion (RPE) were ranked on a 4-point [29], 7-point [29] and 15-point scale [30], respectively. Thermal comfort ranged from 1 (comfortable) to 4 (very uncomfortable), Thermal sensation from − 3 (very cold) to 3 (very hot), and RPE from 6 (very very light) to 20 (maximal exertion). Subjective parameters were scored at baseline, every 5 min during the warm-up phase, every 3 min during the incremental phase and every 5 min during the recovery phase.
Environmental Conditions
Tambient and RH were measured using a portable climate-monitoring device (Davis Instruments Inc., Hayward, CA, USA) positioned at table height in the centre of the climate chamber, and the ambient vapour pressure and absolute humidity were calculated accordingly.
Statistical Analysis
Minute averages of Tgi, Tsk and HR were calculated using a customized MATLAB and Statistics Toolbox (2012b, The MathWorks, Inc., Natick, MA, USA) software package. All parameters were visually inspected for normality. Continuous variables were normally distributed and presented as mean ± SD, whereas categorical variables were presented as median [interquartile range (IQR)] or as proportions. Paired-samples t tests were used to compare exercise characteristics and thermoregulatory responses between the control and Tokyo conditions. The Wilcoxon Signed ranks-test was used to compare subjective outcome measures between the control and Tokyo conditions. A one-way ANOVA with Bonferroni post hoc testing was used to compare exercise characteristics and thermoregulatory responses across sport disciplines. Kruskal–Wallis tests with the Dunn-Bonferroni post hoc method were used to compare subjective outcome measures across sport disciplines. Pearson’s correlation analysis was used to assess bi-variate associations. Statistical analyses were performed with SPSS Statistics 25 (IBM Corp, Armonk, NY, USA). Data were considered to be significant if p < 0.05.
Results
Participants
A total of 106 elite athletes from 11 different sport types participated in this study. One participant dropped out due to an ankle injury that was incurred during training and was excluded from further analyses. Participant characteristics of the analytical cohort (n = 105) and detailed information about classification of sport disciplines are presented Table 1. Due to technical difficulties, we missed Tgi observations in seven athletes (n = 3 in the control and n = 4 in the Tokyo condition). The exercise tests were conducted between 20 November 2018 and 30 April 2019 and between 21 October 2019 to 23 January 2020. In addition, two athletes were tested in June 2019 as they were not available earlier due to their intense training schedules. None of the participating athletes conducted a dedicated heat acclimatization program prior to participation and only four athletes reported having some heat exposure but were not acclimatized. The average time between study visits was 8 ± 6 days, with a minimum of 48 h.
Exercise Performance
TTE was 16 ± 8 min shorter in the Tokyo compared to the control condition (Table 2, p < 0.001), corresponding to a 26 ± 11% reduction in exercise performance. Accordingly, PPO declined with 0.5 ± 0.3 W/kg in the Tokyo versus control condition (Table 2, p < 0.001), corresponding to a 16 ± 7% reduction in exercise performance. The reductions in exercise performance were not different across sport disciplines (Fig. 1A, B, Table 3). Nevertheless, large variations in the magnitude of performance reductions between individual athletes were observed (Fig. 1C, D).
Table 2.
Control condition | Tokyo condition | p value | |
---|---|---|---|
Exercise characteristics | |||
Time to exhaustion (min) | 60 ± 14 | 44 ± 10 | < 0.001* |
Peak power output (W) | 230 ± 63 | 193 ± 54 | < 0.001* |
Peak power output (W/kg) | 3.1 ± 1.0 | 2.6 ± 0.8 | < 0.001* |
Resting HR (bpm) | 74 ± 12 | 82 ± 14 | < 0.001* |
Exercise-induced increase in HR (bpm) | 105 ± 14 | 101 ± 15 | 0.005* |
Peak HR (bpm) | 179 ± 12 | 182 ± 11 | < 0.001* |
WBSR (L/h) | 0.8 ± 0.3 | 1.4 ± 0.6 | < 0.001* |
Dehydration (%) | 1.1 ± 0.4 | 1.3 ± 0.5 | < 0.001* |
Thermoregulatory responses | |||
Resting Tgi (°C) | 37.1 ± 0.4 | 37.1 ± 0.4 | 0.23 |
Exercise-induced increase in Tgi (°C) | 1.5 ± 0.5 | 1.8 ± 0.6 | < 0.001* |
Exercise-induced increase rate in Tgi (°C/h) | 1.6 ± 0.5 | 2.5 ± 0.8 | < 0.001* |
Peak Tgi (°C) | 38.7 ± 0.4 | 38.9 ± 0.6 | < 0.001* |
Resting Tsk (°C) | 30.5 ± 0.7 | 33.6 ± 0.7 | < 0.001* |
Exercise-induced increase in Tsk (°C) | 1.8 ± 0.9 | 3.1 ± 0.9 | < 0.001* |
Peak Tsk (°C) | 32.3 ± 1.1 | 36.7 ± 0.6 | < 0.001* |
Subjective outcomes | |||
Resting thermal sensation (au) | − 2 (− 3 to 1) | 1 (0–3) | < 0.001* |
Peak thermal sensation (au) | 3 (0–3) | 3 (2–3) | < 0.001* |
Resting thermal comfort (au) | 2 (1–4) | 1 (1–3) | < 0.001* |
Peak thermal comfort (au) | 4 (1–4) | 4 (2–4) | < 0.001* |
Resting RPE (au) | 6 (6–10) | 6 (6–10) | 0.47 |
Peak RPE (au) | 20 (14–20) | 20 (12–20) | 0.11 |
Data are presented as mean ± SD or median (interquartile range)
au arbitrary units, bpm beats per minute, HR heart rate, RPE rating of perceived exertion, Tgi gastrointestinal temperature, Tsk skin temperature, W watt, WBSR whole body sweat rate
*p < 0.05
Table 3.
Endurance-trained athletes (N = 27) | Mixed-trained athletes (N = 31) | Power-trained athletes (N = 12) | Skill-trained athletes (N = 35) | p value | |
---|---|---|---|---|---|
Exercise characteristics | |||||
Time to exhaustion (min) | |||||
Control (min) | 64 ± 13 | 57 ± 14 | 59 ± 6 | 60 ± 16 | 0.19 |
Tokyo (min) | 47 ± 9 | 40 ± 10 | 44 ± 5 | 45 ± 11 | 0.05 |
Δ (min) | 18 ± 9 | 17 ± 9 | 15 ± 5 | 14 ± 9 | 0.39 |
Δ time to exhaustion (%) | 27 ± 9 | 29 ± 11 | 25 ± 7 | 23 ± 12 | 0.17 |
Peak power output (W) | |||||
Control (W) | 287 ± 50b,c,d | 243 ± 50a,d | 239 ± 51a,d | 171 ± 31a,b,c | < 0.001* |
Tokyo (W) | 238 ± 46b,d | 202 ± 44a,d | 202 ± 44d | 148 ± 30a,b,c | < 0.001* |
Δ (W) | 49 ± 19d | 41 ± 21d | 37 ± 15 | 24 ± 12a,b | < 0.001* |
Δ peak power output (%) | 17 ± 7 | 17 ± 8 | 16 ± 5 | 14 ± 7 | 0.24 |
Normalized peak power output (W/kg) | |||||
Control (W/kg) | 4.4 ± 0.5b,c,d | 3.0 ± 0.4a,d | 3.0 ± 0.4a,d | 2.2 ± 0.5a,b,c | < 0.001* |
Tokyo (W/kg) | 3.7 ± 0.5b,c,d | 2.5 ± 0.3a,d | 2.6 ± 0.3a,d | 1.9 ± 0.4a,b,c | < 0.001* |
Δ (W/kg) | 0.8 ± 0.3b,c,d | 0.5 ± 0.3a,d | 0.5 ± 0.2a | 0.3 ± 0.2a,b | < 0.001* |
Δ normalized peak power output (%) | 17 ± 7 | 17 ± 8 | 16 ± 5 | 14 ± 7 | 0.24 |
Resting HR (bpm) | |||||
Control (bpm) | 72 ± 15 | 71 ± 9c | 82 ± 11b | 77 ± 11 | 0.002* |
Tokyo (bpm) | 75 ± 14c,d | 78 ± 10c | 95 ± 16a,b | 85 ± 13a | < 0.001* |
Δ (bpm) | 3 ± 17 | 7 ± 11 | 12 ± 12 | 9 ± 9 | 0.14 |
Exercise-induced increase in HR (bpm) | |||||
Control (bpm) | 112 ± 15d | 103 ± 11 | 106 ± 11 | 100 ± 13a | 0.007* |
Tokyo (bpm) | 111 ± 12b,c,d | 100 ± 13a | 97 ± 18a | 95 ± 14a | < 0.001* |
Δ (bpm) | 1 ± 18 | 3 ± 13 | 9 ± 14 | 5 ± 10 | 0.33 |
Peak HR (bpm) | |||||
Control (bpm) | 183 ± 10b | 174 ± 9a,c | 188 ± 6b,d | 177 ± 13c | < 0.001* |
Tokyo (bpm) | 186 ± 9b | 178 ± 12a,c | 192 ± 9b,d | 180 ± 11c | 0.001* |
Δ (bpm) | 3 ± 5 | 4 ± 8 | 4 ± 6 | 4 ± 8 | 0.85 |
Thermoregulatory responses | |||||
Resting Tgi (°C) | |||||
Control (°C) | 37.0 ± 0.4c | 37.0 ± 0.3c | 37.4 ± 0.3a,b | 37.2 ± 0.3 | 0.006* |
Tokyo (°C) | 37.1 ± 0.3 | 37.0 ± 0.5 | 37.3 ± 0.3 | 37.2 ± 0.5 | 0.13 |
Δ (°C) | 0.0 ± 0.3 | 0.1 ± 0.4 | 0.1 ± 0.2 | 0.0 ± 0.5 | 0.62 |
Exercise-induced increase in Tgi (°C) | |||||
Control (°C) | 1.7 ± 0.5d | 1.6 ± 0.5 | 1.5 ± 0.3 | 1.4 ± 0.4a | 0.048* |
Tokyo (°C) | 2.3 ± 0.6b,d | 1.7 ± 0.6a | 1.8 ± 0.6 | 1.6 ± 0.5a | < 0.001* |
Δ (°C) | 0.6 ± 0.4d | 0.2 ± 0.5 | 0.3 ± 0.6 | 0.2 ± 0.6a | 0.020* |
Exercise-induced increase rate in Tgi (°C/h) | |||||
Control (°C/h) | 1.7 ± 0.6 | 1.7 ± 0.5 | 1.5 ± 0.3 | 1.5 ± 0.4 | 0.23 |
Tokyo (°C/h) | 3.0 ± 0.9d | 2.6 ± 0.6 | 2.5 ± 0.6 | 2.1 ± 0.5a | < 0.001* |
Δ (°C/h) | 1.4 ± 0.6b,d | 0.9 ± 0.6a | 0.9 ± 0.6 | 0.7 ± 0.6a | < 0.001* |
Peak exercise Tgi (°C) | |||||
Control (°C) | 38.8 ± 0.4 | 38.6 ± 0.5 | 38.9 ± 0.3 | 38.6 ± 0.4 | 0.10 |
Tokyo (°C) | 39.4 ± 0.5b,d | 38.6 ± 0.5a | 39.1 ± 0.5 | 38.8 ± 0.5a | < 0.001* |
Δ (°C) | 0.6 ± 0.4b,d | 0.1 ± 0.4a | 0.2 ± 0.4 | 0.2 ± 0.4a | < 0.001* |
Resting Tsk (°C) | |||||
Control (°C) | 30.5 ± 0.7 | 30.4 ± 0.8 | 30.3 ± 0.6 | 30.6 ± 0.7 | 0.6 |
Tokyo (°C) | 33.7 ± 0.6 | 33.8 ± 0.7 | 33.8 ± 0.6 | 33.3 ± 0.8 | 0.038* |
Δ (°C) | 3.1 ± 0.8 | 3.4 ± 0.9d | 3.5 ± 0.7d | 2.7 ± 0.7b,c | 0.004* |
Exercise-induced increase in Tsk (°C) | |||||
Control (°C) | 2.4 ± 0.8b,d | 1.6 ± 0.7a | 1.7 ± 1.3 | 1.4 ± 0.8a | < 0.001* |
Tokyo (°C) | 3.6 ± 0.7b | 2.8 ± 0.7a | 3.0 ± 0.9 | 3.1 ± 0.9 | 0.004* |
Δ (°C) | 1.1 ± 0.8 | 1.2 ± 1.0 | 1.2 ± 1.0 | 1.8 ± 1.0 | 0.046* |
Peak exercise Tsk (°C) | |||||
Control (°C) | 33.0 ± 1.0b,d | 32.0 ± 1.0a | 32.1 ± 1.5 | 32.0 ± 0.9a | 0.001* |
Tokyo (°C) | 37.3 ± 0.6b,d | 36.6 ± 0.5a | 36.8 ± 0.8 | 36.4 ± 0.5a | < 0.001* |
Δ (°C) | 4.3 ± 1.0 | 4.5 ± 1.0 | 4.7 ± 1.0 | 4.5 ± 0.9 | 0.62 |
Whole body sweat rate (WBSR) | |||||
WBSR (L/h) | |||||
Control (L/h) | 0.9 ± 0.3d | 0.9 ± 0.4d | 0.8 ± 0.3 | 0.7 ± 0.2a,b | 0.001* |
Tokyo (L/h) | 1.6 ± 0.6c,d | 1.7 ± 0.6c,d | 1.1 ± 0.3a,b | 1.0 ± 0.3a,b | < 0.001* |
Δ (L/h) | 0.6 ± 0.3d | 0.8 ± 0.4c,d | 0.3 ± 0.2b | 0.3 ± 0.3a,b | < 0.001* |
Dehydration (%) | |||||
Control (%) | 1.4 ± 0.3b,c,d | 1.0 ± 0.4a | 1.0 ± 0.3a | 0.8 ± 0.3 a | < 0.001* |
Tokyo (%) | 1.8 ± 0.5b,c,d | 1.3 ± 0.3a,d | 1.0 ± 0.3a | 0.9 ± 0.3a,b | < 0.001* |
Δ (%) | 0.3 ± 0.4d | 0.3 ± 0.3d | 0.1 ± 0.3 | 0.1 ± 0.3a.b | < 0.001* |
Subjective measures | |||||
Resting thermal sensation (au) | |||||
Control (au) | − 2 (− 3 to 0) | − 2 (− 3 to 0) | − 2 (− 3 to 1) | − 1 (− 3 to 0) | 0.14 |
Tokyo (au) | 1 (0–3) | 1 (0–2) | 2 (0–3) | 1 (0–2) | 0.80 |
Peak thermal sensation (au) | |||||
Control (au) | 3 (0–3) | 3 (1–3) | 3 (2–3) | 3 (1–3) | 0.20 |
Tokyo (au) | 3 (3–3) | 3 (2–3) | 3 (3–3) | 3 (2–3) | 0.46 |
Resting thermal comfort (au) | |||||
Control (au) | 2 (1–3) | 2 (1–3) | 2 (1–4) | 2 (1–3) | 0.25 |
Tokyo (au) | 1 (1–3)b,d | 1 (1–2)a,c | 2 (1–3)b,d | 1 (1–3)a,c | 0.046* |
Peak thermal comfort (au) | |||||
Control (au) | 4 (1–4) | 4 (1–4) | 4 (2–4) | 3 (2–4) | 0.326 |
Tokyo (au) | 4 (3–4)c | 4 (3–4)c | 4 (4–4)a,b | 4 (2–4) | 0.031* |
Resting RPE (au) | |||||
Control (au) | 6 (6–7) | 6 (6–10) | 6 (6–6) | 6 (6–10) | 0.22 |
Tokyo (au) | 6 (6–8) | 6 (6–8) | 6 (6–6) | 6 (6–10) | 0.20 |
Peak RPE (au) | |||||
Control (au) | 20 (16–20) | 20 (18–20) | 20 (18–20) | 20 (14–20) | 0.29 |
Tokyo (au) | 20 (12–20) | 20 (17–20) | 20 (18–20) | 20 (15–20) | 0.28 |
Data are presented as mean ± SD, n (%), or median (interquartile range)
Δ delta control versus Tokyo condition, au arbitrary units, bpm beats per minute, HR heart rate, RPE rating of perceived exertion, Tgi gastrointestinal temperature, Tsk skin temperature, W watt, WBSR whole body sweat rate
*p < 0.05. Significantly different from (a) endurance-trained athletes, (b) mixed-trained athletes, (c) power-trained athletes, (d) skill-trained athletes
Thermoregulatory Responses
Resting Tgi was comparable across conditions (p = 0.30, Table 2), but larger exercise-induced Tgi increases, higher Tgi rates and higher peak Tgi values were found in the Tokyo versus control condition (all p values < 0.001, Table 2). The distinct pattern in peak Tgi responses was even more evident after standardization for exercise duration (Fig. 2A). Larger interindividual variations in exercise-induced increases in Tgi (range 0.7–3.5 °C vs. 0.7–3.0 °C) and peak Tgi (range 37.6–40.4 °C vs. 37.7–39.7 °C) were found across athletes in the Tokyo condition compared to the control condition (Fig. 3D). Peak Tgi values were moderately correlated across both conditions (Pearson’s r = 0.59, p < 0.001). There were no associations between peak Tgi or exercise-induced increase in Tgi and the relative changes in TTE or PPO (Fig. 4). Furthermore, endurance-trained athletes demonstrated greater exercise-induced increases in Tgi (Table 3) and reached higher peak Tgi values (Fig. 3B) compared to mixed- and skill-trained athletes in the Tokyo condition. Moreover, endurance-trained athletes demonstrated a higher Tgi rate in the Tokyo condition compared to skill-trained athletes (Table 3). Additional comparisons of thermoregulatory responses across sport disciplines are presented in Table 3.
Resting Tsk, exercise-induced increase in Tsk, and peak Tsk were higher in the Tokyo versus the control condition (all p values < 0.001, Table 2, Fig. 2B). Exercise-induced increases in Tsk, and peak Tsk were higher in endurance-trained athletes compared to mixed- and skill-trained athletes across both conditions (Table 3).
Heart Rate, Whole Body Sweat Rate and Subjective Outcomes
Resting HR was higher in the Tokyo versus control condition (p < 0.001, Table 2), increased during both conditions (Fig. 2C), whereas greater exercise-induced increases and higher peak values were found in the Tokyo versus control condition (both p < 0.001, Table 2). Sport discipline-specific differences in resting HR, exercise-induced increases in HR and peak HR were observed in both conditions (Table 3).
WBSR and dehydration levels were higher in the Tokyo versus control condition (both p < 0.001, Table 2). Endurance and mixed athletes demonstrated a higher WBSR compared to power athletes in the Tokyo condition (Table 3). Relative losses in total body weight were the highest in endurance trained athletes compared to mixed-, power- and skill-trained athletes in both conditions (Table 3).
Peak thermal sensation and peak thermal comfort scores deteriorated in the Tokyo compared to the control condition (all ps < 0.001, Table 2). Maximum RPE did not differ across conditions (p = 0.11). Higher peak thermal comfort scores were observed in power-trained athletes compared to endurance- and mixed-trained athletes (Table 3).
Discussion
The current study provides a unique insight into the changes in exercise performance and thermoregulatory responses among a large and heterogeneous cohort of elite athletes exercising in hot and humid environmental conditions as compared to control conditions. As expected, larger exercise-induced increases in Tgi were observed in the Tokyo versus control condition. The magnitude of these thermoregulatory responses was more prominent in endurance-trained athletes compared to mixed- and skill-trained athletes, whereas thermal perception was more affected in power-trained athletes. More importantly, a dramatic loss in exercise performance was found (− 26 ± 11%), independent of sports discipline. Also, large interindividual variations were present for peak Tgi and performance loss, whereas no association was found between these outcome measures. Findings from this study indicate that the Tokyo environmental conditions have a significant impact on the thermoregulatory responses and performance capacity of Dutch elite athletes. The magnitude of physiological responses to heat is highly variable across individuals, underlining the need for individualized heat mitigation strategies to optimize exercise performance and to minimize the potential risk of heat illness in preparation for the Tokyo Olympics.
Exercise Performance
TTE declined by 26 ± 11% in the Tokyo condition, with 25% of the athletes demonstrating a performance loss > 35%. The magnitude of this decrement is lower compared to previous lab-based studies in low-to-moderate-trained individuals (range − 29% to − 48%) [8, 31–33]. Study-specific differences in exercise protocol, intensity (absolute workload), duration and environmental conditions may contribute to the observed variability of heat-induced performance loss. Alternatively, regular exposure to high-volume and/or high-intensity exercise training is known to induce partial heat acclimatization [34–36], which could explain the attenuated heat-induced performance loss in elite athletes compared to low-to-moderate-trained individuals who were primarily tested in previous studies. Two of our participants even demonstrated an improved exercise capacity in the heat. A case-by-case review revealed no abnormalities in physiological responses or exercise performance parameters, highlighting that the continuum of changes in exercise performance in the heat ranges from large decrements to small improvements. Taken together, exercise in the heat induces large reductions in performance for the majority of elite athletes.
Thermoregulatory Responses
A larger increase in Tgi was observed in the Tokyo versus control condition. This finding aligns with our hypothesis and observations from previous studies [8, 37, 38], as the hot and humid environmental conditions narrow the heat transfer gradients between the skin surface and the ambient environment, attenuating the possibility of dissipating heat generated by skeletal muscles [39]. The high humidity and the lack of wind speed further limit the possibility of evaporation, resulting in a significantly lower heat-loss potential [40]. The limited heat-loss potential in the Tokyo condition resulted in a distinct pattern in time-dependent changes of Tgi across conditions (Fig. 2A). Increases in Tgi level-off after 20 min in the control condition, whereas a continuous rise until exercise cessation is observed in the Tokyo condition. These findings may indicate uncompensatable heat stress in the Tokyo condition [41], which might result in severe hyperthermia and an increased risk for heat illness if exercise is performed at higher absolute workloads and/or continued for a longer time.
Subjective Measures
Power-trained athletes reported higher rest and peak thermal comfort scores compared to endurance- and mixed-trained athletes. This is an interesting observation as thermal perception can affect exercise performance independent of core temperature changes [42, 43]. Skin temperature is the primary driver of thermal comfort during exercise in the heat [29, 44], but peak exercise Tsk was lower in power versus endurance athletes and comparable between power- and mixed-trained athletes. On the other hand, the difference in peak exercise Tsk between the control and Tokyo conditions was the largest for power-trained athletes (Table 3), but this value did not significantly differ from other athlete groups. Alternatively, body composition is known to impact thermal comfort scores [45]. Power athletes had a higher body mass index (BMI; 25.4 ± 1.3 kg/m2) compared to endurance- (20.9 ± 1.4 kg/m2) and mixed-trained athletes (20.9 ± 1.4 kg/m2, p < 0.001), which may contribute to the difference in thermal perception scores [45]. Nevertheless, we must also acknowledge that performance loss was not different for power athletes, so their worse thermal comfort score did not result in an additional attenuation of exercise performance in the heat.
Interindividual Variations
We observed large interindividual variations in thermoregulatory responses with a peak Tgi ranging from 37.6 to 40.4 °C in the Tokyo condition. Although the level of hyperthermia was moderate for the whole cohort (peak Tgi 38.9 ± 0.6 °C) and aligned with previous observations in literature [8, 31–33], substantial differences were found across sport disciplines. Endurance-trained athletes showed larger increases (2.3 ± 0.6 °C) and higher peak values of Tgi (39.4 ± 0.5 °C) compared to mixed- (1.7 ± 0.6 °C and 38.6 ± 0.5 °C) and skill- (1.6 ± 0.5 °C and 38.8 ± 0.5 °C) trained athletes. The difference in absolute peak workload (and associated metabolic heat production) per unit mass between endurance (3.7 ± 0.5 W/kg) mixed- (2.5 ± 0.3 W/kg) and skill-trained athletes (1.9 ± 0.4 W/kg) is likely responsible for this finding [46] as exercise duration was comparable across groups (Table 1). Therefore, endurance-trained athletes were in an uncompensatable state for a longer period compared to other groups, given the higher workload per unit mass. In contrast to the thermoregulatory responses, no differences in performance decrements were observed across sport disciplines. This observation suggests that endurance-trained athletes may have a better heat tolerance compared to other sport disciplines. The lack of an overall association between peak Tgi and performance outcomes (Fig. 4) further substantiates this hypothesis as within-subject variations in Tgi are known to impact performance capacity [47], but between-subject variations may reflect differences in heat tolerance instead. Taken together, the magnitude of physiological responses is highly variable across elite athletes in simulated Tokyo 2020 conditions, emphasizing the importance of testing athletes to determine their individual needs for specific heat-mitigation measures.
Individualized Countermeasures
The large interindividual variations, the differences observed across sport disciplines, and the absence of a significant association between Tgi and performance indicators emphasize that it is impossible to offer a ‘one-size-fits-all’ heat-mitigation strategy to elite athletes. Participants in the present study were non-acclimatized, indicating that the physiological responses represent a worst-case scenario, but also highlight a large window of opportunity to improve thermoregulation and exercise performance in the heat. Heat acclimatization is the most important countermeasure one can adopt [48], and must be implemented in the training plan of an athlete [15, 18]. Cooling interventions [16, 17, 49] and hydration strategies [50] are other effective measures to attenuate the deleterious effects of exercise in the heat. Each heat-mitigation strategy should be individualized based on the athlete’s thermophysiological responses and performance losses during exercise in the heat, and must be practiced during training and competition prior to the Olympic Games.
Strengths and Limitations
Our study used a well-controlled maximal exercise protocol and included a unique and large group of 105 elite athletes, in order to provide a comprehensive insight into the effects of the Tokyo environmental conditions on thermoregulatory responses and exercise performance. However, some limitations should be taken into account. First, a possible weakness of our study is the lack of a randomized study design, as the first exercise test was always conducted in the control condition to obtain the heart rate-based personalized exercise protocol (i.e. changes in workload over time) for both conditions. We preferred this approach over a time-trial performance protocol, as the latter may induce additional variability in performance and pacing levels in athletes inexperienced in such types of exercise (e.g., field hockey, sailing, beach volleyball) due to learning effects [51]. We also considered adding a familiarization session to our protocol, allowing randomization of the two other sessions. However, representatives of TeamNL and sports federations advised against such an approach due to the busy training schedules of elite athletes and the impracticability of exposing them to multiple exercise tests within a short period. Therefore, we deliberately chose the current approach that allows us to use personalized protocols, and obtain thermoregulatory responses and performance outcomes by two study visits only. Second, athletes were not allowed to drink during the exercise protocol to avoid interference with the measurements of the ingestible temperature capsule [24], but this may also have exaggerated the effect of heat on thermoregulation and performance due to accelerated dehydration [52]. Third, the exercise protocol does not reflect the nature of sport-specific activities and related (behavioural) thermoregulatory responses, limiting the external validity and potentially a direct translation to field settings. However, outcomes of our standardized exercise test have a high internal validity and may aid coaches in specifically collecting field data in athletes with abnormal responses, such as a large performance loss or high peak Tgi, which aligns with the goal of the Thermo Tokyo study.
Conclusion
Exercise performance was severely affected among non-acclimatized elite athletes exercising in a hot and humid environment as evidenced by a 26 ± 11% lower time to exhaustion. We also observed larger increases of core temperature and skin temperature in the Tokyo versus the control condition, with aggravated responses in endurance athletes (greater exercise-induced increases in Tgi and peak Tgi) and power athletes (deteriorated thermal perception). The magnitude of performance loss and thermoregulatory responses were highly variable across individuals, whereas no association was found between these outcome measures. These findings emphasize the importance of extensive testing of elite athletes to determine their individual needs for heat mitigation strategies (i.e. heat acclimatization, cooling interventions, hydration plan). Such an approach will likely contribute to safe and maximal exercise performance during the challenging environmental conditions of the Tokyo 2020 Olympic Games and other future competitions in challenging hot and humid environments.
Supplementary Information
Below is the link to the electronic supplementary material.
Acknowledgements
The authors would like to thank the participating athletes (including their coaches and staff) for their participation and dedication to the study. The authors would also like to thank NOC*NSF and Sport Science and Innovation Centre Papendal for their valuable assistance with the recruitment and data collection, and for the use of their climate chamber. We recognize the excellent assistance of Sam Ballak, Lars Bouten, Dominique ten Haaf, Iris Hesen, Bregina Kersten, Joep van Kesteren, Sophie Kroesen, Meijke Linders and Malou Nuijten with data collection for the present study.
Declarations
Funding
This work was funded by a ZonMW Grant (#546001003) as part of the Thermo Tokyo project.
Conflict of interest
Yannick de Korte, Coen Bongers, Maria Hopman and Thijs Eijsvogels declare that they have no competing interests.
Availability of data and material
Data are available upon reasonable request.
Author contributions
JQK and TMHE were involved in the conception of the study design and protocol. JQK, CCWGB and TMHE were involved in the data collection. JQK analysed the data and was responsible for initial writing and drafting of the article. CCWGB, MTEH and TMHE critically revised the manuscript. The final manuscript was approved by all authors.
Ethics approval
The study was approved by the Medical Ethics Committee of the Radboud University Medical Centre (#2018-4640).
Consent to participate
All participants gave written informed consent prior to the testing procedure.
Consent for publication
Not required.
@YannickdeKorte, @BongersCoen, @ThijsEijsvogels.
References
- 1.Gerrett N, Kingma BRM, Sluijter R, Daanen HAM. Ambient conditions prior to Tokyo 2020 Olympic and Paralympic Games: considerations for acclimation or acclimatization strategies. Front Physiol. 2019;10(414):414. doi: 10.3389/fphys.2019.00414. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Kakamu T, Wada K, Smith DR, Endo S, Fukushima T. Preventing heat illness in the anticipated hot climate of the Tokyo 2020 Summer Olympic Games. Environ Health Prev Med. 2017;22(1):68. doi: 10.1186/s12199-017-0675-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Sawka MN, Leon LR, Montain SJ, Sonna LA. Integrated physiological mechanisms of exercise performance, adaptation, and maladaptation to heat stress. Compr Physiol. 2011;1(4):1883–1928. doi: 10.1002/cphy.c100082. [DOI] [PubMed] [Google Scholar]
- 4.American College of Sports M. Armstrong LE, Casa DJ, Millard-Stafford M, Moran DS, Pyne SW, et al. American College of Sports Medicine position stand. Exertional heat illness during training and competition. Med Sci Sports Exerc. 2007;39(3):556–572. doi: 10.1249/MSS.0b013e31802fa199. [DOI] [PubMed] [Google Scholar]
- 5.Cheuvront SN, Haymes EM. Thermoregulation and marathon running: biological and environmental influences. Sports Med (Auckland, NZ) 2001;31(10):743–762. doi: 10.2165/00007256-200131100-00004. [DOI] [PubMed] [Google Scholar]
- 6.Racinais S, Moussay S, Nichols D, Travers G, Belfekih T, Schumacher YO, et al. Core temperature up to 41.5 masculineC during the UCI Road Cycling World Championships in the heat. Br J Sports Med. 2019;53(7):426–429. doi: 10.1136/bjsports-2018-099881. [DOI] [PubMed] [Google Scholar]
- 7.Nybo L, Rasmussen P, Sawka MN. Performance in the heat-physiological factors of importance for hyperthermia-induced fatigue. Compr Physiol. 2014;4(2):657–689. doi: 10.1002/cphy.c130012. [DOI] [PubMed] [Google Scholar]
- 8.Galloway SD, Maughan RJ. Effects of ambient temperature on the capacity to perform prolonged cycle exercise in man. Med Sci Sports Exerc. 1997;29(9):1240–1249. doi: 10.1097/00005768-199709000-00018. [DOI] [PubMed] [Google Scholar]
- 9.Bouchama A, Knochel JP. Heat stroke. N Engl J Med. 2002;346(25):1978–1988. doi: 10.1056/NEJMra011089. [DOI] [PubMed] [Google Scholar]
- 10.Casa DJ, DeMartini JK, Bergeron MF, Csillan D, Eichner ER, Lopez RM, et al. National Athletic Trainers' Association Position Statement: exertional heat illnesses. J Athl Train. 2015;50(9):986–1000. doi: 10.4085/1062-6050-50.9.07. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Veltmeijer MT, Eijsvogels TM, Thijssen DH, Hopman MT. Incidence and predictors of exertional hyperthermia after a 15-km road race in cool environmental conditions. J Sci Med Sport. 2015;18(3):333–337. doi: 10.1016/j.jsams.2014.04.007. [DOI] [PubMed] [Google Scholar]
- 12.Racinais S, Ihsan M, Taylor L, Cardinale M, Adami PE, Alonso JM, et al. Hydration and cooling in elite athletes: relationship with performance, body mass loss and body temperatures during the Doha 2019 IAAF World Athletics Championships. Br J Sports Med. 2021 doi: 10.1136/bjsports-2020-103613. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Veltmeijer MT, Thijssen DH, Hopman MT, Eijsvogels TM. Within-subject variation of thermoregulatory responses during repeated exercise bouts. Int J Sports Med. 2015;36(8):631–635. doi: 10.1055/s-0034-1398676. [DOI] [PubMed] [Google Scholar]
- 14.van Delden M, Bongers C, Broekens D, Daanen HAM, Eijsvogels TMH. Thermoregulatory burden of elite sailing athletes during exercise in the heat: a pilot study. Temperature (Austin, Tex) 2019;6(1):66–76. doi: 10.1080/23328940.2018.1540964. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Racinais S, Alonso JM, Coutts AJ, Flouris AD, Girard O, Gonzalez-Alonso J, et al. Consensus Recommendations on Training and Competing in the Heat. Sports Med (Auckland, NZ) 2015;45(7):925–938. doi: 10.1007/s40279-015-0343-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Bongers CCWG, de Korte JQ, Infographic Eijsvogels T. Keep it cool and beat the heat: cooling strategies for exercise in hot and humid conditions. Br J Sports Med. 2021;55(11):643–644. doi: 10.1136/bjsports-2020-102294. [DOI] [PubMed] [Google Scholar]
- 17.Bongers CC, Thijssen DH, Veltmeijer MT, Hopman MT, Eijsvogels TM. Precooling and percooling (cooling during exercise) both improve performance in the heat: a meta-analytical review. Br J Sports Med. 2015;49(6):377–384. doi: 10.1136/bjsports-2013-092928. [DOI] [PubMed] [Google Scholar]
- 18.Racinais S, Ihsan M. Why should I test my athletes in the heat several months before Tokyo 2020? Br J Sports Med. 2020;54(12):700–701. doi: 10.1136/bjsports-2020-102082. [DOI] [PubMed] [Google Scholar]
- 19.Havenith G, van Middendorp H. The relative influence of physical fitness, acclimatization state, anthropometric measures and gender on individual reactions to heat stress. Eur J Appl Physiol Occup Physiol. 1990;61(5):419–427. doi: 10.1007/BF00236062. [DOI] [PubMed] [Google Scholar]
- 20.Misner JE, Boileau RA, Massey BH, Mayhew JL. Alterations in the body composition of adult men during selected physical training programs. J Am Geriatr Soc. 1974;22(1):33–38. doi: 10.1111/j.1532-5415.1974.tb02156.x. [DOI] [PubMed] [Google Scholar]
- 21.Pelliccia A, Sharma S, Gati S, Back M, Borjesson M, Caselli S, et al. 2020 ESC Guidelines on sports cardiology and exercise in patients with cardiovascular disease. Eur Heart J. 2021;42(1):17–96. doi: 10.1093/eurheartj/ehaa605. [DOI] [PubMed] [Google Scholar]
- 22.de Korte JQ, Bongers CCWG, Hopman MTE, Teunissen LPJ, Jansen KMB, Kingma BRM, et al. Performance and thermoregulation of Dutch Olympic and Paralympic athletes exercising in the heat: Rationale and design of the Thermo Tokyo study: the journal Temperature toolbox. Temperature. 2021 doi: 10.1080/23328940.2021.1925618. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Weinert D, Waterhouse J. The circadian rhythm of core temperature: effects of physical activity and aging. Physiol Behav. 2007;90(2–3):246–256. doi: 10.1016/j.physbeh.2006.09.003. [DOI] [PubMed] [Google Scholar]
- 24.Wilkinson DM, Carter JM, Richmond VL, Blacker SD, Rayson MP. The effect of cool water ingestion on gastrointestinal pill temperature. Med Sci Sports Exerc. 2008;40(3):523–528. doi: 10.1249/MSS.0b013e31815cc43e. [DOI] [PubMed] [Google Scholar]
- 25.Bongers C, Hopman MTE, Eijsvogels TMH. Validity and reliability of the myTemp ingestible temperature capsule. J Sci Med Sport. 2018;21(3):322–326. doi: 10.1016/j.jsams.2017.06.006. [DOI] [PubMed] [Google Scholar]
- 26.Bongers C, Daanen HAM, Bogerd CP, Hopman MTE, Eijsvogels TMH. Validity, reliability, and inertia of four different temperature capsule systems. Med Sci Sports Exerc. 2018;50(1):169–175. doi: 10.1249/MSS.0000000000001403. [DOI] [PubMed] [Google Scholar]
- 27.Standard I. 9886 . Ergonomics—evaluation of thermal strain by physiological measurements. 2. International Standard Organization; 2004. pp. 1–21. [Google Scholar]
- 28.Sawka MN, Noakes TD. Does dehydration impair exercise performance? Med Sci Sports Exerc. 2007;39(8):1209–1217. doi: 10.1249/mss.0b013e318124a664. [DOI] [PubMed] [Google Scholar]
- 29.Gagge AP, Stolwijk JAJ, Hardy JD. Comfort and thermal sensations and associated physiological responses at various ambient temperatures. Environ Res. 1967;1(1):1–20. doi: 10.1016/0013-9351(67)90002-3. [DOI] [PubMed] [Google Scholar]
- 30.Borg G. Perceived exertion as an indicator of somatic stress. Scand J Rehabil Med. 1970;2(2):92–98. [PubMed] [Google Scholar]
- 31.Girard O, Racinais S. Combining heat stress and moderate hypoxia reduces cycling time to exhaustion without modifying neuromuscular fatigue characteristics. Eur J Appl Physiol. 2014;114(7):1521–1532. doi: 10.1007/s00421-014-2883-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Mitchell JB, Rogers MM, Basset JT, Hubing KA. Fatigue during high-intensity endurance exercise: the interaction between metabolic factors and thermal stress. J Strength Cond Res. 2014;28(7):1906–1914. doi: 10.1519/JSC.0000000000000319. [DOI] [PubMed] [Google Scholar]
- 33.Rowland T, Garrison A, Pober D. Determinants of endurance exercise capacity in the heat in prepubertal boys. Int J Sports Med. 2007;28(1):26–32. doi: 10.1055/s-2006-924142. [DOI] [PubMed] [Google Scholar]
- 34.Ravanelli N, Coombs GB, Imbeault P, Jay O. Maximum skin wettedness after aerobic training with and without heat acclimation. Med Sci Sports Exerc. 2018;50(2):299–307. doi: 10.1249/MSS.0000000000001439. [DOI] [PubMed] [Google Scholar]
- 35.Shvartz E, Shapiro Y, Magazanik A, Meroz A, Birnfeld H, Mechtinger A, et al. Heat acclimation, physical fitness, and responses to exercise in temperate and hot environments. J Appl Physiol Respir Environ Exerc Physiol. 1977;43(4):678–683. doi: 10.1152/jappl.1977.43.4.678. [DOI] [PubMed] [Google Scholar]
- 36.Ely BR, Ely MR, Cheuvront SN, Kenefick RW, Degroot DW, Montain SJ. Evidence against a 40 degrees C core temperature threshold for fatigue in humans. J Appl Physiol (1985) 2009;107(5):1519–1525. doi: 10.1152/japplphysiol.00577.2009. [DOI] [PubMed] [Google Scholar]
- 37.Tucker R, Rauch L, Harley YX, Noakes TD. Impaired exercise performance in the heat is associated with an anticipatory reduction in skeletal muscle recruitment. Pflugers Arch. 2004;448(4):422–430. doi: 10.1007/s00424-004-1267-4. [DOI] [PubMed] [Google Scholar]
- 38.Periard JD, Racinais S. Performance and pacing during cycle exercise in hyperthermic and hypoxic conditions. Med Sci Sports Exerc. 2016;48(5):845–853. doi: 10.1249/MSS.0000000000000839. [DOI] [PubMed] [Google Scholar]
- 39.Périard JD, Racinais S. Heat stress in sport and exercise: thermophysiology of health and performance. Springer; 2019. [Google Scholar]
- 40.Vanos JK, Grundstein AJ. Variations in athlete heat-loss potential between hot-dry and warm-humid environments at equivalent wet-bulb globe temperature thresholds. J Athl Train. 2020;55(11):1190–1198. doi: 10.4085/1062-6050-313-19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Cheung SS, McLellan TM, Tenaglia S. The thermophysiology of uncompensable heat stress. Physiological manipulations and individual characteristics. Sports Med (Auckland, NZ). 2000;29(5):329–359. doi: 10.2165/00007256-200029050-00004. [DOI] [PubMed] [Google Scholar]
- 42.Tucker R, Marle T, Lambert EV, Noakes TD. The rate of heat storage mediates an anticipatory reduction in exercise intensity during cycling at a fixed rating of perceived exertion. J Physiol. 2006;574(Pt 3):905–915. doi: 10.1113/jphysiol.2005.101733. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Schlader ZJ, Simmons SE, Stannard SR, Mundel T. Skin temperature as a thermal controller of exercise intensity. Eur J Appl Physiol. 2011;111(8):1631–1639. doi: 10.1007/s00421-010-1791-1. [DOI] [PubMed] [Google Scholar]
- 44.Nakamura M, Yoda T, Crawshaw LI, Yasuhara S, Saito Y, Kasuga M, et al. Regional differences in temperature sensation and thermal comfort in humans. J Appl Physiol (1985) 2008;105(6):1897–1906. doi: 10.1152/japplphysiol.90466.2008. [DOI] [PubMed] [Google Scholar]
- 45.Schweiker M, Huebner GM, Kingma BRM, Kramer R, Pallubinsky H. Drivers of diversity in human thermal perception—a review for holistic comfort models. Temperature (Austin, Tex). 2018;5(4):308–342. doi: 10.1080/23328940.2018.1534490. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Cramer MN, Jay O. Selecting the correct exercise intensity for unbiased comparisons of thermoregulatory responses between groups of different mass and surface area. J Appl Physiol (1985) 2014;116(9):1123–1132. doi: 10.1152/japplphysiol.01312.2013. [DOI] [PubMed] [Google Scholar]
- 47.Ely BR, Cheuvront SN, Kenefick RW, Sawka MN. Aerobic performance is degraded, despite modest hyperthermia, in hot environments. Med Sci Sports Exerc. 2010;42(1):135–141. doi: 10.1249/MSS.0b013e3181adb9fb. [DOI] [PubMed] [Google Scholar]
- 48.Racinais S, Alonso JM, Coutts AJ, Flouris AD, Girard O, Gonzalez-Alonso J, et al. Consensus recommendations on training and competing in the heat. Br J Sports Med. 2015;49(18):1164–1173. doi: 10.1136/bjsports-2015-094915. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Taylor L, Carter S, Stellingwerff T. Cooling at Tokyo 2020: the why and how for endurance and team sport athletes. Br J Sports Med. 2020;54(21):1243–1245. doi: 10.1136/bjsports-2020-102638. [DOI] [PubMed] [Google Scholar]
- 50.Periard JD, Eijsvogels T, Daanen HAM, Racinais S. Hydration for the Tokyo Olympics: to thirst or not to thirst? Br J Sports Med. 2021;55(8):410–411. doi: 10.1136/bjsports-2020-102803. [DOI] [PubMed] [Google Scholar]
- 51.Corbett J, Barwood MJ, Parkhouse K. Effect of task familiarisation on distribution of energy during a 2000 m cycling time trial. Br J Sports Med. 2009;43(10):770–774. doi: 10.1136/bjsm.2008.056416. [DOI] [PubMed] [Google Scholar]
- 52.Sawka MN, Cheuvront SN, Kenefick RW. Hypohydration and human performance: impact of environment and physiological mechanisms. Sports Med (Auckland, NZ). 2015;45(Suppl 1):S51–60. doi: 10.1007/s40279-015-0395-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.