Binder-free printed PEDOT wearable sensors on everyday fabrics using oxidative chemical vapor deposition

Michael Clevenger 1,, Hyeonghun Kim 1,, Han Wook Song 2, Kwangsoo No 3, Sunghwan Lee 1,*
PMCID: PMC8519566  PMID: 34652946

Health-monitoring sensors directly fabricated on disposable wears using oxidative chemical vapor deposition.

Abstract

Polymeric sensors on fabrics have vast potential toward the development of versatile applications, particularly when the ready-made wearable or fabric can be directly coated. However, traditional coating approaches, such as solution-based methods, have limitations in achieving uniform and thin films because of the poor surface wettability of fabrics. Herein, to realize a uniform poly(3,4-ethylenedioxythiophene) (PEDOT) layer on various everyday fabrics, we use oxidative chemical vapor deposition (oCVD). The oCVD technique is a unique method capable of forming patterned polymer films with controllable thicknesses while maintaining the inherent advantages of fabrics, such as exceptional mechanical stability and breathability. Utilizing the superior characteristics of oCVD PEDOT, we succeed in fabricating blood pressure– and respiratory rate–monitoring sensors by directly depositing and patterning PEDOT on commercially available disposable gloves and masks, respectively. Those results are expected to pave efficient and facile ways for skin-compatible and affordable sensors for personal health care monitoring.

INTRODUCTION

With the upsurge of interest in health monitoring systems and noninvasive human/machine interfaces, wearable and stretchable electronic devices have been extensively studied in the past decade (16). In particular, wearable sensors that are capable of extracting important bioinformation such as body temperature (5), blood pressure (BP) (3), or respiratory patterns (6) from the human body without the aid of medical experts and immobile instruments have demonstrated particular promise for the development of future portable health care systems. While the development of these sensory devices are specifically tailored and specialized depending on which types of bioinformation are being analyzed, or where the intended location of the sensor is being placed, the flexibility and robustness of these sensors must be ensured to guarantee the compatibility of the device on any location of the human body and the prolonged service despite undergoing the mechanical stress and strain caused by daily motion (16).

In an effort to provide flexibility, elastomers such as polyimide, polydimethylsiloxane, or fabrics have been adopted as device substrates (16). Among them, fabrics have shown tremendous advantages in remarkable stability, skin compatibility, and breathability and in being lightweight (79). Moreover, if a sensor is able to be directly fabricated onto ready-made wearables, such as clothes, gloves, or disposable masks, then one can monitor their health status with minimized inconvenience. However, owing to the rough nature of the fabric surface, high porosity, and surface hydrophobicity, the formation of a uniform sensing film on the fabric has been regarded as a daunting task compared to developing films on flat and rigid substrates. This issue is especially noticed when using solution-processed conductive polymers, which are one of the most commonly used materials for wearable sensors, because the thin-film formation of the materials relies on a liquid-phase deposition technique and its processing requirements such as surface wetting. Solution-based techniques, such as in situ chemical polymerization (1012), dip-coating (1316), or drop-casting methods (17, 18) have been used for coating a polymeric film onto a fabric. However, these conventional methods have been limited because of the requirements of suitable surface wettability and required chemical functional groups on the fabrics for binding liquid-phase monomers or dispersed polymers in a solvent. In addition, the harsh conditions required for the liquid-based methods, such as necessary acid treatment or annealing processing temperatures higher than 150°C (14, 19), have become another factor limiting the types of candidates for sensor substrates. Furthermore, the usage of additives, such as binders, that are often used for improving conformability of versatile fabrics, ultimately failed to maintain the inherent advantages of the fabrics (e.g., breathability or skin compatibility), as well as ultimately lower the conductivity because of the insulating nature of the binder (2022).

Oxidative chemical vapor deposition (oCVD) has recently emerged as an innovative and unique method for synthesizing conductive polymer films with superior conductivity (2325). Functionally, the conductive polymer films are synthesized through the polymerization of a vaporized monomer and oxidizing agent. The vapor-phase reagents uniformly coat the whole surface of any substance regardless of surface morphology and wetting properties, enabling highly uniform polymer layers on virtually any substrates. The outstanding step coverage facilitated by the oCVD technique has been a breakthrough for a wide range of research fields such as light-emitting diodes (26), lithium-ion batteries (27), or redox-flow batteries (28), where oCVD polymers have been conformally coated on vertically aligned nanowires or porous media. However, for wearable sensors, there has been limited progress to date.

Herein, we use the oCVD technique for creating a conformal poly(3,4-ethylenedioxythiophene) (PEDOT) layer on multiple fabrics (nylon, polyester, and cotton) and disposable wearables (commercially available glove and mask) for sensory devices without any binders or additives. The oCVD technique is capable of creating a highly conductive PEDOT film where thickness is readily controllable from ~10 nm to thicker than 1 μm by varying the deposition time. Moreover, the mechanical stability, breathability, and lightness of fabrics are consistent even after the PEDOT coating, implying that oCVD PEDOT is notably promising as an active material for potential wearable devices. On the basis of the unique properties associated with oCVD-deposited PEDOT, we fabricate prototype resistive sensors by directly printing PEDOT on a commercially available disposable glove and mask, made of polymer fabrics such as polypropylene or polyester. The sensors successfully demonstrate capabilities of extracting BP information and respiratory rates in real time with remarkable precision. This is the first report proving the usability of the oCVD method on fabric-based sensors, thus paving the way for developing versatile health care devices.

RESULTS

Schematic of oCVD and characterization of oCVD PEDOT deposited on fabrics

The oCVD technique offers clear advantages over solution-based polymer-coating methods because of its ability to conformally coat complex geometries regardless of surface functionalities (e.g., hydrophobicity). Shown in Fig. 1A, a schematic of the oCVD chamber illustrates the gas-phase deposition process. EDOT monomers are vaporized and metered into the chamber via a needle valve, in which the monomers react with sublimated FeCl3 (oxidizing agent). The structure of the oCVD reactors is further described in fig. S1. Through step-growth polymerization, PEDOT chains are deposited onto the upside-down substrate. The substrates can be mounted in a way in which shadow masking is possible to selectively exposed areas. An example of this can be viewed in Fig. 1B, where a Purdue “P” was patterned onto polyester fabric via oCVD deposition of PEDOT, as well as line patterns onto medical gauze.

Fig. 1. Characterization of oCVD PEDOT.

Fig. 1.

(A) Schematic of the oCVD process. (B) Photo image of patterned oCVD PEDOT on fabrics: polyester (left) and gauze (right). (C) FTIR spectra of oCVD PEDOT–deposited on silicon and polyester substrates. a.u., arbitrary units. (D) Conductivity and bendability of oCVD PEDOT–deposited on polyester with different thicknesses and deposition temperatures. (E) Breathability test of bare and oCVD PEDOT–coated fabric. Photo credit: Hyeonghun Kim, Purdue University.

Figure 1C shows Fourier-transform infrared (FTIR) spectra. Comparison between PEDOT films deposited on fabric and Si substrates shows clear similarities of peak locations, indicating that oCVD PEDOT was well synthesized on fabric. The peak located at a wavelength of ~1550 nm is related to C═C stretching indicative of standard PEDOT films in the thiophene ring and is observed in PEDOT on both fabric and Si substrates. Peak presence at ~1425 nm on both fabric and Si substrates indicates both C─C and C─H bonds, characteristic of PEDOT films. The additional presence of the C─O bond located at ~1350 nm is shared between the films deposited on both substrates. Strong peaks shown at ~1080, 1110, and 1160 nm represent prominent C─O─C bonding, indictive of the ethylenedioxy group. In short, FTIR spectra of oCVD PEDOT films identified the characteristic chemical bonds of C═C, C─C, C─H, S, and C─O─C, which are coincided with previous works, solidifying the claim of successful PEDOT deposition on a fabric substrate (29, 30).

To confirm the mechanical flexibility of PEDOT films, we conducted bending tests on fabric samples coated with various-thickness oCVD PEDOT films deposited at different substrate temperatures. For the bending test, the samples were bent 180° to generate high stress and strain on the fabrics, and their sheet resistances were measured every cycle. Values of sheet resistance (Rs) were then converted to the comparable term conductivity, which is regarded as nominal compared to standard conductivity measurements on flat surfaces, using the equation σ = 1/(Rs × t) with the film thickness t. PEDOT deposited on fabric was shown to maintain its conductive performance more than 100 bending cycles (Fig. 1D). This exemplifies PEDOT’s excellent mechanical flexibility and resilience to bending and strain cycles that typical wearable fabrics would undergo.

Comparing PEDOT films (~200 nm thick) deposited at various temperatures, the conductivity of PEDOT notably increases with higher substrate temperatures. To investigate the temperature effect in more detail, we investigated the conductivity of PEDOT, grown on flat glass substrates at various deposition temperatures from 50° to 130°C. From this investigation, fig. S2 demonstrates that the conductivity increases linearly below 100°C. FTIR (fig. S3) and atomic force microscopy (fig. S4) analysis of the films substantiate that high deposition temperatures lead to a longer conjugation length and larger grain-like structures of oCVD PEDOT films, both of which are eligible factors to increase the conductivity of the polymer (3032). Moreover, the uniform coverage of the oCVD PEDOT on fabrics could be achieved even as the thickness of the polymer is up to 1 μm (fig. S5).

A breathability test was conducted to determine whether the air permeability of the fabrics is compromised because of the coated PEDOT film on the fabric. The test consisted of covering and sealing vials filled with deionized water with bare fabric or oCVD PEDOT–deposited fabric of varying thicknesses. The vials were then heated via a hot plate to encourage water evaporation. The resulting water vapor would then permeate through the fabrics into the surrounding environment. To track the amount of water released, we measured the mass of the water at specific intervals across 48 hours. The relationship of remaining water mass in the vials to time can be shown in Fig. 1E. From the figure, the rate of evaporation for bare fabric can be found to be ~0.036 g hour−1. oCVD PEDOT’s rate was found to be ~0.031 g hour−1, showing a negligible change in breathability from bare fabric to oCVD PEDOT–deposited fabric. Among oCVD PEDOT fabrics, no clear difference is seen between fabrics of varying thicknesses, showcasing oCVD PEDOT’s ability to maintain fabric breathability regardless of film thickness. This consistent high breathability indicates the enhanced versatility of oCVD PEDOT for wearable devices as film thickness can be adjusted per application without having to consider the effect on breathability.

Comparison between oCVD PEDOT and solution-processed PEDOT:PSS

To visualize the clear benefits of the oCVD deposition technique over traditional solution-based processing, we applied oCVD PEDOT and solution-processed PEDOT:polystyrene sulfonate (PSS) (deposited via dip coating) on three different fabric types: nylon, polyester, and cotton. We selected a standard PEDOT:PSS solution as a representative material for a solution process, considering its same polymer backbone structure as oCVD PEDOT. As shown in Fig. 2A, the oCVD process succeeded in coating uniform films on all the fabrics. However, the dip-casting process failed at uniform coating on hydrophobic fabrics like nylon and polyester. While there is a slight increase in wettability for PEDOT:PSS deposited on cotton fabrics, the resulting films are still highly nonuniform as evidenced by the uneven coloration indicating thickness variation across the film.

Fig. 2. Comparison between oCVD PEDOT and PEDOT:PSS.

Fig. 2.

(A) Photo images of fabrics (nylon, polyester, and cotton) coated by oCVD PEDOT and PEDOT:PSS. The insets demonstrate a droplet of PEDOT:PSS solution on each fabric, representing the fabric’s hydrophobicity. (B) Uniformity tests: fabricating multiple electrode pairs on PEDOT-coated polyesters using silver paste with a channel width of 6 mm and different channel lengths from 6 to 30 mm. (C) SEM images of oCVD PEDOT and PEDOT:PSS on polyester before and after bending 100 cycles. (D) Resistance change during the bending tests. Photo credit: Hyeonghun Kim, Purdue University.

Simple rectangular channels were created on fabric using both oCVD PEDOT and PEDOT:PSS to compare the spatial uniformity between the oCVD PEDOT and solution-based PEDOT:PSS films (a detailed method is described in the Supplementary Materials with fig. S6). In this case, channel length was varied between 6 and 30 mm while channel width was kept constant. As shown in Fig. 2B, oCVD PEDOT clearly follows standard channel-length modulation practices, as the resistance scales linearly with channel length with minimal error among multiple samples. However, PEDOT:PSS fabric showed a much larger variation in resistance and the lack of a linear trend with the channel length, indicating that the solution-based coating does not yield uniform conductance of the film grown on fabric, compared to the oCVD PEDOT. It is expected that any polymer solutions are difficult to be uniformly coated on various substrates because of the material-dependent wettability issues. In contrast, the vapor-phase oCVD process is capable of uniform polymer coating virtually on any type of substrates including fabric, thus having greater benefits for fabricating fabric-based devices.

Scanning electron microscopy (SEM) images of oCVD PEDOT and PEDOT:PSS deposited onto polyester fabrics are shown before and after bending in Fig. 2C. SEM images were taken to confirm the conformality of oCVD PEDOT films on fabric threads versus the nonuniformity consistently observed in PEDOT:PSS throughout this study. The threads in PEDOT:PSS films are substantially bridged by the PEDOT:PSS coating, reducing the open pore ratio of fabric and critically limiting the breathability. oCVD PEDOT, on the other hand, shows clear conformality, both before and after 100 bending cycles. PEDOT:PSS, however, shows notable film tearing and separation from threads after bending, leading to overall lack of uniformity and performance of PEDOT:PSS when compared to oCVD PEDOT. The notable uniformity difference between oCVD PEDOT and PEDOT:PSS could be also identified for nylon and cotton fabrics as shown in fig. S6.

To confirm the mechanical flexibility of oCVD PEDOT, we conducted bending tests to examine the change in overall resistance, and therefore conductivity of oCVD PEDOT films throughout bending. The results were compared to those of traditional solution-processed PEDOT:PSS. From the plot in Fig. 2C, it can be seen that throughout bending, oCVD PEDOT maintains its nearly identical resistance level, and therefore conductivity with only a 4% deviation across all cycles from its initial measurement. PEDOT:PSS, however, showed a 400% increase in resistance, indicating consequential amounts of degradation. The occurrence of this degradation can be clearly explained by the tendency for PEDOT:PSS films to tear and separate, as shown in Fig. 2D. The mechanical flexibility and reliable conductivity performance of oCVD PEDOT, despite undergoing multiple bending cycles, highlights the efficacy of the oCVD vapor-phase deposition technique and its ability to conformally coat complex geometries with high film uniformity.

Wearable sensors using oCVD PEDOT

The oCVD PEDOT having demonstrated exceptional conformability on fabrics, and stability has much potential to be implemented as an active material for sensor applications. Here, we fabricated prototype wearable sensors by directly depositing oCVD PEDOT onto commercially available disposable gloves and masks. Figure 3A demonstrates a schematic and a photograph (inset) for a pressure sensor printed on a glove of which thread consists of a mixture of polyester and polyethylene. The tip of the index finger was covered by patterned oCVD PEDOT of 1.5 cm of length and 0.5 cm of width. The ends of the PEDOT were then connected with copper electrode tape connected to a source meter.

Fig. 3. oCVD PEDOT on the glove for BP sensor.

Fig. 3.

(A) Schematic and photo image of oCVD PEDOT sensor fabricated on a polyester glove. (B) Transient current curve, recorded at 0.1 V under applying a pressure of 1.8 kPa. The inset demonstrates current change occurring under a pressure of 200 Pa. (C) Current change occurring under different pressure. The slope represents the sensitivity of the sensor. (D) Response and (E) recovery times, measured applying 1.8 kPa. (F) Schematic showing a working mechanism of the oCVD PEDOT pressure sensor. (G to J) BP measurements. (G) The radial artery BP recording by placing the sensor on the wrist and (H) an extended image of it showing a single pulse, (I) the carotid artery BP recording by placing the sensor on the neck, and (J) an extended image of it showing a single pulse. Photo credit: Hyeonghun Kim, Purdue University.

The current change, recorded at a bias of 0.1 V, was investigated under a wide range of pressures (Fig. 3, B to E). The sensitivity tests were conducted by pressing the PEDOT film with a weight-loaded slide glass. The current markedly increased by 1400% when 1.8 kPa of pressure is applied to the center of the PEDOT film (Fig. 3B). Even when undergoing a minute pressure of 200 Pa (the inset of Fig. 3B), a significant response was still observable (200% change). The current drops, occurring from the moment of pressing and releasing, were attributed to transitory charge generation caused by the triboelectric effect between the glass and the PEDOT surface (fig. S8) (33). In general, the triboelectric phenomenon takes place in a short moment (<10 ms) and rapidly reaches an equilibrium state. Therefore, as shown in fig. S8, the sensing response (current variation, recorded at the equilibrium state) was not appreciably disturbed by the triboelectric effect. The sensitivity is defined as δ(∆I/I0)/δP, where I0 is the initial current and ∆I is the current change (%) induced by applying pressure (P). The oCVD PEDOT sensor demonstrated a notable sensitivity of 8 kPa−1, which is enough to use the oCVD-based fabric sensor for the measurement of various bioinformation from the human body (Fig. 3C). As a important figure of merit for pressure sensors, we also measured the operation rates of the PEDOT sensor. The response time is defined as the time period required for the current level to reach 90% of the saturation state as pressure is applied, while the recovery time is the time period to reach 10% of the saturation level after the pressure is removed (Fig. 3D). Response and recovery times of 260 and 30 ms, respectively, were recorded while applying and releasing an approximate pressure of 1.8 kPa. It should be noted that the performance of oCVD PEDOT sensors is comparable to previously reported resistive devices based on conductive polymers (table S1) (3447), even without any additives or sophisticated device structure in our sensors.

The working principle of the oCVD PEDOT sensor is described in Fig. 3F. As with other typical fabrics, the glove consists of “warp” and “weft” threads, one of which wraps the other in the vertical direction. When the oCVD process is initiated, the gas-phase monomers and oxidizing agents cover every open facet of the yarn, and the PEDOT layer uniformly coats the exposed surfaces. In contrast, the adhered region between warp and weft (denoted as the shaded region), which is too compact to permit the access of the gas molecules, is not coated by the conductive PEDOT film and still remains a nonconductive region. With no pressure applied, the selective surface covering makes the current flow in the fabric only through the internal path on each thread. When pressure is applied, the flexible PEDOT-coated threads are structurally deformed as shown in the right of Fig. 3F. Compared to the unpressured state, the deformation increases the contact area of the PEDOT films between the warp and weft, which creates an additional current path. In this case, the current flows not only through a single thread but also through multiconductive paths from the crossover between threads. This is the operational mechanism of the oCVD PEDOT–based fabric sensor where the overall conductivity is proportional to the applied pressure (Fig. 3C). Moreover, the elasticity of polymers is high enough to rapidly restore the crossover state to an unpressured state once the pressure is removed, enabling the fast recovery behavior as shown in Fig. 3E.

On the basis of the high sensitivity and fast response rates, the oCVD PEDOT sensor was expected to qualify for tracking BP information. The pressure range (<2 kPa), used for investigating the sensitivity of our sensor, is much lower compared to an actual BP that is in a range of 10 to 16 kPa (80 to 120 mmHg). However, the pivotal goal of the glove sensor in this research is to identify a BP pattern measuring the associated pressure changes from a pulse at the wrist or neck under a mild pressing condition. Using this mild pressure condition, a user is equipped with the device with minimal inconvenience, unlike conventional cuff-type BP instruments that compress an arm or wrist until blood flow is blocked. Pang et al. (48) used an ultralight strain-gauge sensor and fixed it gently on a wrist to monitor a BP pattern. They succeeded in tracking the pattern information in real time with minimized discomfort although the recorded pressure value was in a range of 500 Pa, much less than that of the actual BP. Likewise, we targeted to measure BP patterns under a similarly mild pressing condition, for which we chose the polyethylene fabric because of its readily deformative characteristic under low pressures.

Figure 3G demonstrates regular pulse patterns, which were measured by placing the fabric sensor onto the radial artery located in the wrist. The radial artery pulse consists of two particular components (Fig. 3H); one (P1) is caused by the main BP from the first beat of the pulse, and the other (P2) represents the reflected peak wave from the secondary beat. The radial artery augmentation index (AI), defined as a ratio of the peak intensities (P1/P2), has been studied as an indicative sign for diagnosing cardiovascular diseases. The AI estimated from the oCVD PEDOT sensor was 0.55, within the normal range of a healthy 20- to 30-year-old individual (4951). In addition, the oCVD PEDOT sensor succeeded in extracting the BP patterns from the neck to measure carotid artery pressure. The carotid AI value (0.38) was slightly lower than that of radial artery pulse and consistent with reported clinical trials (51). Those results substantiate the capability of the glove sensor to extract meaningful BP information from multiple points in the human body without the aid of medical experts and immobile instruments. To test the stability and endurance of our sensors, we submitted PEDOT-coated fabrics to repeated standard use tests and abrasion cycles. The standard use test consisted of applying our sensor to the skin in concurrence with the typical use outlined for the BP sensor. For the abrasion cycles, the surface of the PEDOT film was repeatedly rubbed against the skin to examine the potential of wear. Each of these tests was conducted across 200 cycles, where the current change was recorded after pressure removal at a voltage of 0.1 V. The results, which can be viewed in fig. S9, showed no degradation of base current after undergoing all 200 cycles of abrasion and standard use, showcasing the endurance capabilities of our sensors.

Respiratory rate is a crucial physiological indicator capable of diagnosing severe respiratory diseases such as cardiopulmonary arrest, chronic heart failure, or pneumonia. In particular, with a marked surge of coronavirus diesease 2019, handy and affordable sensors equipped with disposable masks have been extensively demanded. In this regard, we fabricated the oCVD PEDOT sensor on a conventional, commercially available, disposable mask, consisting of two nonwoven fabrics (a mixture of Spandex and polypropylene) and a melt-blown filter (polypropylene) interposed between them (Fig. 4A). It should be noted that the oCVD technique provides an exceptional capability to directly form a uniform and thin patterned PEDOT film (~100 nm) on the mask without any secondary assembling processes.

Fig. 4. oCVD PEDOT on the mask for respiratory rate sensor.

Fig. 4.

(A) Schematic and photo images of oCVD PEDOT sensor fabricated on a disposable mask. The top images demonstrate a schematic of the mask sensor and an actual sensor image; the bottom photo images represent the instant deformation of the mask during inhalation and exhalation. (B) Breath patterns measured at an initial state (left), after 10-min exercise (middle), and further 10-min break (right). A single respiratory pattern, measured at (C) the normal and (D) as soon as after the exercise. Photo credit: Michael Clevenger and Hyeonghun Kim, Purdue University.

Figure 4B compares current change, recorded at a bias of 0.1 V, before and after 5-min exercise (running). The signal of the mask sensor is susceptible to environmental conditions and the facial shape of the subject. Besides, the base current is expected to gradually shift during long-term use. Therefore, for the practical use of the sensor, the current fluctuation, affected by the exterior reasons, should be corrected on the basis of a proper signal processing algorithm to automatically extract respiratory information. The procedure for the data processing is described in the Supplementary Materials with fig. S11 in more detail. The initial rate was 16 to 20 min−1, which is raised up to 40 to 42 min−1 after running. The pattern was completely restored after enough rest time (>10 min). A single breath pulse for each state is described in Fig. 4 (C and D). For both normal and running states, inhalation caused a current drop that is recovered during exhalation. The period was shortened from 3.0 to 3.8 s to 1.4 to 1.5 s after exercise, and the amount of current change for each cycle was far beyond the noise level of our sensor, ensuring a precise measurement. With the standard respiratory rate for an adult being between 12 and 20 min−1, and the abnormal rate being either below 12 min−1 or above 25 min−1 (5255), by showcasing the clear change in rate from 16 to 20 min−1 to 40 to 42 min−1 after running and then a decrease back to 12 to 14 min−1, the mask sensor has shown the capability to measure the respiration rate and to detect the difference between normal and abnormal ranges, which is an important factor in identifying potential illnesses associated with abnormal respiratory rate including, but not limited to, lung degradation, anxiety, fever, and cardiac conditions (5255).

To identify the working principle of the mask sensor in more detail, we conducted additional electrical measurements (fig. S10) that emulate the working environment of the mask sensor. For a case where the sensor is placed on a compact glass slide and its two ends fixated (fig. S10B), the vertical pressing (1 kPa) on the sensor did not cause a substantial current rise (fig. S10C), contrary to the glove sensor (Fig. 3). For the glove sensor, which is much more sensitive to applied vertical pressure, the current increment is attributed to the contact resistance variation between the warp and weft threads, accompanied by the structural deformation of those threads. However, the nonwoven outer fabric in the mask, which is previously compressed during its manufacturing process, consists of too compactly stacked threads (the inset of fig. S10A) to be transformed under mild pressure. Thus, the mask sensor was relatively insensitive to the applied vertical pressure.

Instead, if the two ends of the sensor were only attached to glass substrates while the center part was free-standing as shown in fig. S10D, then the pressure applied on the center of the fabric caused the current drop (fig. S10E) of which the amount of variation was 8.5 times more than that of the first case (fig. S10, B and C). The underlying principle of the current change for the second case is based on the elongation of the fabric induced by the pressure. The electrical resistance of the PEDOT-coated outer nonwoven fabric, consisting of compactly stacked threads, is determined by the combination of the internal resistance of each PEDOT-coated thread and the contact resistance between them. During the elongation, some of the conjunction points between threads are disconnected, bringing about a depression of charge transport through the interthread path that is related to the contact resistance; thus, the pronounced current drop that appeared during the pressing.

When the mask is equipped and fixated around the face, an air gap exists around the nostrils and mouth. The softness of fabrics allows shrinkage and recovery of the space accompanied by the instant structural deformation of the mask during repeated respiration. Considering the inhalation process, the air gap is gradually curtailed, and the center of the mask is bent inward (the bottom of Fig. 4A), which is similar to the deformation described in fig. S10D. As discussed above, some conjunction points between the PEDOT-coated threads are detached during the elongation caused by the inhalation, resulting in an incremental change of the contact resistance between the PEDOT layers. As exhalation initiates, the deformation and change in conductivity from the induced gap are recovered to that of the normal condition. Thus, a repeatable breathing pattern can be electronically recorded by the real-time measurement of resistance of the PEDOT-coated layer.

DISCUSSION

Herein, we explored the conformability of the oCVD method on multiple fabrics (nylon, polyester, and cotton). The vapor-phase injection of reactants enables a uniform coating on any substrate regardless of their porosity or hydrophobicity. The thickness of the coating is controllable from 10 to thicker than 1000 nm by varying deposition time and temperature. Notably, compared to a dip-casting method using the PEDOT:PSS solution, the oCVD PEDOT’s bendability was exceptionally superior while maintaining the inherent advantages of fabrics such as breathability. On the basis of the outstanding features of oCVD PEDOT as an active material for wearable devices, we fabricated two prototype sensors by directly patterning and depositing PEDOT on a commercially available disposable glove and mask. The glove sensor successfully served as a precise pressure sensor, capable of extracting BP information from the radial or carotid artery by simply touching the wrist or neck. The respiratory rate–monitoring sensor, printed on the disposable mask, was able to monitor breathing patterns in real time. To the best of our knowledge, this is the first report of vapor-printing sensors directly fabricated on ready-made masks. The utilization of the oCVD technique, paired with the conjugated polymer PEDOT, has proven to be certainly advantageous in terms of strong adhesion between the sensing layer and wearable fabrics, contrary to conventional approaches of which the sensory parts need to be prepared separately first and then assembled later on the resulting wearable. Therefore, the oCVD process is a groundbreaking addition toward the development of wearable devices in ready-made clothes (or masks) that can monitor personal health care information without the aid of medical experts and immobile instruments.

While the scope of our paper was the development of low-cost disposable sensors, which were intended to limit any potential spread of contagious diseases and therefore did not require a washing capability, the challenge of longevity is definitely of great consideration. Because most polymers are typically not known for their resistance to large amounts of direct water and detergent contact like general electrical components, the initial focus of this research was made on manufacturing one-time sensors. However, we are considering potential methods to mitigate this challenge through the examination of gas-phase passivation, film thickness modulation, or composite film generation compatible with the oCVD process using additional substances better suited for increased longevity when facing washing cycles. We believe that the progress would broaden the application of the CVD polymer technique into versatile wearable electronic applications.

MATERIALS AND METHODS

oCVD process

oCVD PEDOT thin films were deposited on glass, silicon (Si), and fabric substrates using a custom reactor (fig. S1) that is an enclosed sealed chamber that maintains conditions to allow for vapor-phase polymerization. EDOT (97%; Sigma-Aldrich) monomer vapors were metered into the chamber using a needle valve after being heated to 130°C to vaporize. Iron chloride oxidizing agent (FeCl3, reagent grade; Sigma-Aldrich), stored in a crucible in the main chamber, was sublimated by heating the crucible to 180°C at a ramping rate of approximately 10°C/min. The working pressure was maintained as 2 × 10−3 torr through the adjustment of the flow rate of the needle valve. Once both the vaporized monomer and the oxidizing agent were introduced and a consistent chamber pressure was achieved, the deposition was initiated by opening the main shutter that covers the substrate. The substrate was maintained at a constant specified temperature (30° to 100°C), dependent on the sample, and the thickness was controlled by varying the deposition time. Last, the PEDOT-coated samples were rinsed with methanol (J.T.Baker) for 10 min to remove unreacted FeCl3 and EDOT monomers and dried in a vacuum desiccator to completely evaporate the methanol solvent. Once completely dried, PEDOT-coated silicon samples were measured for thickness using a FilmSense FS-1 Ellipsometer. This thickness measurement was used as the nominal thickness for all PEDOT-coated fabric samples deposited concomitantly with the silicon samples (56, 57). Comparing the nominal thickness with the cross-sectional SEM images, directly obtained from PEDOT-coated nylon samples (fig. S12), revealed less than a 5% difference in thickness and therefore clearly validated the indirect thickness monitoring approach used in this study.

PEDOT:PSS coating on fabrics

Fabrics, precleaned by isopropyl alcohol (IPA), were dip-casted into a PEDOT:PSS solution (PH 1000, Ossila) for 30 min to adsorb the required amount of polymers. The samples were then annealed on a 50°C hot plate for 30 min and stored in a vacuum desiccator for a day to eliminate the residual solvents.

Materials characterization

Functional groups on PEDOTs were analyzed by FTIR spectroscopy (Nexus 670 ThermoNicolet Spectrometer) with an Attenuated Total Reflection accessory. PEDOT films on fabrics were observed using a Thermo Fisher Scientific Teneo scanning electron microscope. The breathability test consisted of filling vials with 3 ml of deionized water. The fabric samples were then placed over the top opening of the vials and sealed around the edge through rubber banding. The vials were then placed equidistant from each other on a hot plate heated to 120°C. Breathability was then calculated via the change in total mass from the evaporation of the water across the test.

Sensor fabrication and characterization

After deposition of PEDOT on fabrics (disposable glove and mask) with a prepatterned shadow mask, two separated copper electrode tabs were bonded on the conductive polymer. Silver paste and carbon tape were interposed between the copper and polymer films to more tightly fix them and minimize electrical noise. The sensor measurements were conducted using a source meter (Agilent 4155B). Alligator clips were used to connected the sensor with the source meter, and the measurement was implemented at a bias of 0.1 V.

Acknowledgments

Funding: This work was partially supported by the U.S. National Science Foundation (NSF) Award no. ECCS-1931088. S.L. and H.W.S. acknowledge the support from the Improvement of Measurement Standards and Technology for Mechanical Metrology (grant no. 20011028) by KRISS. K.N. was supported by Basic Science Research Program (NRF-2021R11A1A01051246) through the NRF Korea funded by the Ministry of Education.

Author contributions: S.L., M.C., and H. K. conceived the study. M.C. prepared the materials. H.K. fabricated the devices. M.C. and H.K. performed the measurements. M.C., H.K., H.W.S., and K.N. analyzed the data. M.C., H.K., and S.L. wrote the manuscript, with input from H.W.S. and K.N.

Competing interests: The authors declare that they have no competing interests.

Data and materials availability: All data needed to evaluate the conclusions in the paper are present in the paper and/or the Supplementary Materials.

Supplementary Materials

This PDF file includes:

Section S1

Table S1

Figs. S1 to S12

References

REFERENCES AND NOTES

  • 1.Wang C., Xia K., Wang H., Liang X., Yin Z., Zhang Y., Advanced carbon for flexible and wearable Electronics. Adv. Mater. 31, 1801072 (2019). [DOI] [PubMed] [Google Scholar]
  • 2.Amjadi M., Kyung K.-U., Park I., Sitti M., Stretchable, skin-mountable, and wearable strain sensors and their potential applications: A review. Adv. Funct. Mater. 26, 1678–1698 (2016). [Google Scholar]
  • 3.Liu Y., Pharr M., Salvatore G. A., Lab-on-skin: A review of flexible and stretchable electronics for wearable health monitoring. ACS Nano 11, 9614–9635 (2017). [DOI] [PubMed] [Google Scholar]
  • 4.Nag A., Mukhopadhyay S. C., Kosel J., Wearable flexible sensors: A review. IEEE Sensors J. 7, 3949–3960 (2017). [Google Scholar]
  • 5.Li Q., Zhang L.-N., Tao X.-M., Ding X., Review of flexible temperature sensing networks for wearable physiological monitoring. Adv. Healthc. Mater. 6, 1601371 (2017). [DOI] [PubMed] [Google Scholar]
  • 6.Servati A., Zou L., Wang Z. J., Ko F., Servati P., Novel flexible wearable sensor materials and signal processing for vital sign and human activity monitoring. Sensors 17, 1622 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Seyedin S., Zhang P., Naebe M., Qin S., Chen J., Wanga X., Razal J. M., Textile strain sensors: A review of the fabrication technologies, performance evaluation and applications. Mater. Horiz. 6, 219–249 (2019). [Google Scholar]
  • 8.Heo J. S., Eom J., Kim Y.-H., Park S. K., Recent progress of textile-based wearable electronics: A comprehensive review of materials, devices, and applications. Small 14, 1703034 (2018). [DOI] [PubMed] [Google Scholar]
  • 9.Acar G., Ozturk O., Golparvar A. J., Elboshra T. A., Böhringer K., Yapici M. K., Wearable and flexible textile electrodes for biopotential signal monitoring: A review. Electronics 8, 479 (2019). [Google Scholar]
  • 10.Opwis K., Knittel D., Gutmann J. S., Oxidative in situ deposition of conductive PEDOT:PTSA on textile substrates and their application as textile heating element. Synth. Met. 162, 1912–1918 (2012). [Google Scholar]
  • 11.Hebeish A., Farag S., Sharaf S., Shaheen T. I., Advancement in conductive cotton fabrics through in situ polymerization of polypyrrole-nanocellulose composites. Carbohydr. Polym. 151, 96–102 (2012). [DOI] [PubMed] [Google Scholar]
  • 12.Tissera N. D., Wijesena R. N., Rathnayake S., de Silva R. M., de Silva K. M. N., Heterogeneous in situ polymerization of polyaniline (PANI) nanofibers on cotton textiles: Improved electrical conductivity, electrical switching, and tuning properties. Carbohydr. Polym. 186, 35–44 (2018). [DOI] [PubMed] [Google Scholar]
  • 13.Pani D., Dessì A., Saenz-Cogollo J. F., Barabino G., Fraboni B., Bonfiglio A., Fully textile, PEDOT:PSS based electrodes for wearable ECG monitoring systems. IEEE Trans. Biomed. Eng. 63, 540–548 (2016). [DOI] [PubMed] [Google Scholar]
  • 14.Ding Y., Invernale M. A., Sotzing G. A., Conductivity trends of PEDOT-PSS impregnated fabric and the effect of conductivity on electrochromic textile. ACS Appl. Mater. Interfaces 2, 1588–1593 (2010). [DOI] [PubMed] [Google Scholar]
  • 15.Ahmed A., Jalil M. A., Hossain M. M., Moniruzzaman M., Adak B., Islam M. T., Parvez M. S., Mukhopadhyay S., A PEDOT:PSS and graphene-clad smart textile-based wearable electronic joule heater with high thermal stability. J. Mater. Chem. C 8, 16204–16215 (2020). [Google Scholar]
  • 16.Ding Y., Yang J., Tolle C. R., Zhu Z., Flexible and compressible PEDOT:PSS@Melamine conductive sponge prepared via one-step dip coating as piezoresistive pressure sensor for human motion detection. ACS Appl. Mater. Interfaces 10, 16077–16086 (2018). [DOI] [PubMed] [Google Scholar]
  • 17.Nuramdhani I., Jose M., Samyn P., Adriaensens P., Malengier B., Deferme W., Mey G. D., Langenhove L. V., Charge-discharge characteristics of textile energy storage devices having different PEDOT:PSS ratios and conductive yarns configuration. Polymer 11, 345 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.del Agua I., Mantione D., Ismailov U., Sanchez-Sanchez A., Aramburu N., Malliaras G. G., Mecerreyes D., Ismailova E., DVS-crosslinked PEDOT:PSS free-standing and textile electrodes toward wearable health monitoring. Adv. Mater. Technol. 3, 1700322 (2018). [Google Scholar]
  • 19.Shi H., Liu C., Jiang Q., Xu J., Effective approaches to improve the electrical conductivity of PEDOT:PSS: A review. Adv. Electron. Mater. 1, 1500017 (2015). [Google Scholar]
  • 20.Åkerfeldt M., Strååt M., Walkenström P., Electrically conductive textile coating with a PEDOT-PSS dispersion and a polyurethane binder. Text. Res. J. 83, 618–627 (2013). [Google Scholar]
  • 21.Tadesse M. G., Mengistie D. A., Chen Y., Wang L., Loghin C., Nierstrasz V., Electrically conductive highly elastic polyamide/lycra fabric treated with PEDOT:PSS and polyurethane. J. Mater. Sci. 54, 9591–9602 (2019). [Google Scholar]
  • 22.Ryan J. D., Mengistie D. A., Gabrielsson R., Lund A., Müller C., Machine-washable PEDOT:PSS dyed silk yarns for electronic textiles. ACS Appl. Mater. Interfaces 9, 9045–9050 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.K. K. Gleason, CVD Polymers: Fabrication of Organic Surfaces and Devices (John Wiley & Sons, 2015). [Google Scholar]
  • 24.Gharahcheshmeh M. H., Tavakoli M. M., Gleason E. F., Robinson M. T., Kong J., Gleason K. K., Tuning, optimization, and perovskite solar cell device integration of ultrathin poly(3,4-ethylenedioxythiophene) films via a single-step all-dry process. Sci. Adv. 5, eaay0414 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Gharahcheshmeh M. H., Gleason K. K., Device fabrication based on oxidative chemical vapor deposition (oCVD) synthesis of conducting polymers and related conjugated organic materials. Adv. Mater. Interfaces 6, 1801564 (2019). [Google Scholar]
  • 26.Krieg L., Meierhofer F., Gorny S., Leis S., Splith D., Zhang Z., von Wenckstern H., Grundmann M., Wang X., Hartmann J., Margenfeld C., Clavero I. M., Avramescu A., Schimpke T., Scholz D., Lugauer H.-J., Strassburg M., Jungclaus J., Bornemann S., Spende H., Waag A., Gleason K. K., Voss T., Toward three-dimensional hybrid inorganic/organic optoelectronics based on GaN/oCVD-PEDOT structures. Nat. Commun. 11, 5092 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Xu G.-L., Liu Q., Lau K. K. S., Liu Y., Liu X., Gao H., Zhou X., Zhuang M., Ren Y., Li J., Shao M., Ouyang M., Pan F., Chen Z., Amine K., Chen G., Building ultraconformal protective layers on both secondary and primary particles of layered lithium transition metal oxide cathodes. Nat. Energy 4, 484–494 (2019). [Google Scholar]
  • 28.Gharahcheshmeh M. H., Wan C. T.-C., Gandomi Y. A., Greco K. V., Forner-Cuenca A., Chiang Y.-M., Brushett F. R., Gleason K. K., Ultrathin conformal oCVD PEDOT coatings on carbon electrodes enable improved performance of redox flow batteries. Adv. Mater. Interfaces 7, 2000855 (2020). [Google Scholar]
  • 29.Lee S., Gleason K. K., Enhanced optical property with tunable band gap of cross-linked PEDOT copolymers via oxidative chemical vapor deposition. Adv. Funct. Mater. 25, 85–93 (2015). [Google Scholar]
  • 30.Drewelow G., Wook Song H., Jiang Z.-T., Lee S., Factors controlling conductivity of PEDOT deposited using oxidative chemical vapor deposition. Appl. Surf. Sci. 501, 144105 (2020). [Google Scholar]
  • 31.Im S. G., Gleason K. H., Systematic control of the electrical conductivity of Poly(3,4-ethylenedioxythiophene) via oxidative chemical vapor deposition. Macromolecuels 40, 6552–6556 (2007). [Google Scholar]
  • 32.Lee S., Paine D. C., Gleason K. K., Heavily doped poly(3,4-ethylenedioxythiophene) thin films with high carrier mobility deposited using oxidative CVD: Conductivity stability and carrier transport. Adv. Funct. Mater. 24, 7187–7196 (2014). [Google Scholar]
  • 33.Liu S., Hua T., Luo X., Lam N. Y., Tao X.-M., Li L., A novel approach to improving the quality of chitosan blended yarns using static theory. Text. Res. J. 85, 1022–1034 (2015). [Google Scholar]
  • 34.Beccatelli M., Villani M., Gentile F., Bruno L., Seletti D., Nikolaidou D. M., Culiolo M., Zappettini A., Coppedè N., All-polymeric pressure sensors based on PEDOT:PSS-modified polyurethane foam. ACS Appl. Polym. Mater. 3, 1563–1572 (2021). [Google Scholar]
  • 35.Zhao P., Zhang R., Tong Y., Zhao X., Zhang T., Tang Q., Liu Y., Strain-discriminable pressure/proximity sensing of transparent stretchable electronic skin based on PEDOT:PSS/SWCNT electrodes. ACS Appl. Mater. Interfaces 12, 55083–55093 (2020). [DOI] [PubMed] [Google Scholar]
  • 36.Li Z., Zhang S., Chen Y., Ling H., Zhao L., Luo G., Wang X., Hartel M. C., Liu H., Xue Y., Haghniaz R., Lee K., Sun W., Kim H., Lee J., Zhao Y., Zhao Y., Emaminejad S., Ahadian S., Ashammakhi N., Dokmeci M. R., Jiang Z., Khademhosseini A., Gelatin methacryloyl-based tactile sensors for medical wearables. Adv. Funct. Mater. 30, 2003601 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Chen T., Zhang S.-H., Lin Q.-H., Wang M.-J., Yang Z., Zhang Y.-L., Wang F.-X., Sun L.-N., Highly sensitive and wide-detection range pressure sensor constructed on a hierarchical-structured conductive fabric as a human–machine interface. Nanoscale 12, 21271–21279 (2020). [DOI] [PubMed] [Google Scholar]
  • 38.Lee J. J., Gandla S., Lim B., Kang S., Kim S., Lee S., Kim S., Alcohol-based highly conductive polymer for conformal nanocoatings on hydrophobic surfaces toward a highly sensitive and stable pressure sensor. NPG Asia Mater. 12, 65 (2020). [Google Scholar]
  • 39.Tseng Y.-T., Lin Y.-C., Shih C.-C., Hsieh H.-C., Lee W.-Y., Chiu Y.-C., Chen W.-C., Morphology and properties of PEDOT:PSS/soft polymer blends through hydrogen bonding interaction and their pressure sensor application. J. Mater. Chem. C 8, 6013–6024 (2020). [Google Scholar]
  • 40.Sun L., Jiang S., Xiao Y., Zhang W., Realization of flexible pressure sensor based on conductive polymer composite via using electrical impedance tomography. Smart Mater. Struct. 29, 055004 (2020). [Google Scholar]
  • 41.Li Y., Jiang C., Han W., Extending the pressure sensing range of porous polypyrrole with multiscale microstructures. Nanoscale 12, 2081–2088 (2020). [DOI] [PubMed] [Google Scholar]
  • 42.Wang J.-C., Karmakar R. S., Lu Y.-J., Chan S.-H., Wu M.-C., Lin K.-J., Chen C.-K., Wei K.-C., Hsu Y.-H., Miniaturized flexible piezoresistive pressure sensors: Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) copolymers blended with graphene oxide for biomedical applications. ACS Appl. Mater. Interfaces 11, 34305–34315 (2019). [DOI] [PubMed] [Google Scholar]
  • 43.Wang Z., Si Y., Zhao C., Yu D., Wang W., Sun G., Flexible and washable poly(ionic liquid) nanofibrous membrane with moisture proof pressure sensing for real-life wearable electronics. ACS Appl. Mater. Interfaces 11, 27200–27209 (2019). [DOI] [PubMed] [Google Scholar]
  • 44.Tsai Y.-J., Wang C.-M., Chang T.-S., Sutradhar S., Chang C.-W., Chen C.-Y., Hsieh C.-H., Liao W.-S., Multilayered Ag NP-PEDOT-paper composite device for human-machine interfacing. ACS Appl. Mater. Interfaces 11, 10380–10388 (2019). [DOI] [PubMed] [Google Scholar]
  • 45.Oh J., Kim J.-H., Park K. T., Jo K., Lee J.-C., Kim H., Son J. G., Coaxial struts and microfractured structures of compressible thermoelectric foams for self-powered pressure sensors. Nanoscale 10, 18370–18377 (2018). [DOI] [PubMed] [Google Scholar]
  • 46.Kweon O. Y., Lee S. J., Oh J. H., Wearable high-performance pressure sensors based on three-dimensional electrospun conductive nanofibers. NPG Asia Mater. 10, 541–551 (2018). [Google Scholar]
  • 47.Qi K., He J., Wang H., Zhou Y., You X., Nan N., Shao W., Wang L., Ding B., Cui S., A highly stretchable nanofiber-based electronic skin with pressure-, strain-, and Flexion-Sensitive properties for health and motion Monitoring. ACS Appl. Mater. Interfaces 9, 42951–42960 (2017). [DOI] [PubMed] [Google Scholar]
  • 48.Pang C., Lee G.-Y., Kim T., Kim S. M., Kim H. N., Ahn S.-H., Suh K.-Y., A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres. Nat. Mater. 11, 795–801 (2012). [DOI] [PubMed] [Google Scholar]
  • 49.Nichols W. W., Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. Am. J. Hypertens. 18, 3S–10S (2005). [DOI] [PubMed] [Google Scholar]
  • 50.Park J., Kim J., Hong J., Lee H., Lee Y., Cho S., Kim S.-W., Kim J. J., Kim S. Y., Ko H., Tailoring force sensitivity and selectivity by microstructure engineering of multidirectional electronic skins. NPG Asia Mater. 10, 163–176 (2018). [Google Scholar]
  • 51.Dagdeviren C., Su Y., Joe P., Yona R., Liu Y., Kim Y.-S., Huang Y. A., Damadoran A. R., Xia J., Martin L. W., Huang Y., Rogers J. A., Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring. Nat. Commun. 5, 4496 (2014). [DOI] [PubMed] [Google Scholar]
  • 52.Al-Khalidi F. Q., Saatchi R., Burke D., Elphick H., Tan S., Respiration rate monitoring methods: A review. Pediatr. Pulmonol. 46, 523–529 (2011). [DOI] [PubMed] [Google Scholar]
  • 53.Fleming S., DPhil T., Stevens R., Heneghan C., Plüddemann A., Maconochie I., Tarassenko L., Mant D., Normal ranges of heart rate and respiratory rate in children from birth to 18 years of age: A systematic review of observational studies. Lancet 377, 1011–1018 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Kelly S. D., Ramsay M. A. E., Respiratory rate monitoring: Characterizing performance for emerging technologies. Anesth. Analg. 119, 1246–1248 (2014). [DOI] [PubMed] [Google Scholar]
  • 55.Rodríguez-Molinero A., Narvaiza L., Ruiz J., Gálvez-Barrón C., Normal respiratory rate and peripheral blood oxygen saturation in the elderly population. J. Am. Geriatr. Soc. 61, 2238–2240 (2013). [DOI] [PubMed] [Google Scholar]
  • 56.Kovacik P., Hierro G., Livernois W., Gleason K. K., Scale-up of oCVD: Large-area conductive polymer thin films for next-generation electronics. Mater. Horiz. 2, 221–227 (2015). [Google Scholar]
  • 57.Allison L. K., Andrew T. L., A wearable all-fabric thermoelectric generator. Adv. Mater. Technol. 4, 1800615 (2019). [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Section S1

Table S1

Figs. S1 to S12

References


Articles from Science Advances are provided here courtesy of American Association for the Advancement of Science

RESOURCES