Multiphoton interference is an important phenomenon in modern quantum mechanics and experimental quantum optics, and it is fundamental for the development of quantum information science and technologies. Over the last three decades, several theoretical and experimental studies have been performed to understand the essential principles underlying such interference and to explore potential applications. Recently, the two-photon interference (TPI) of phase-randomized weak coherent states has played a key role in the realization of long-distance quantum communication based on the use of classical light sources. In this context, we investigated TPI experiments with weak coherent pulses at the single-photon level and quantitatively analyzed the results in terms of the single- and coincidence-counting rates and one- and two-photon interference-fringe shapes. We experimentally examined the Hong–Ou–Mandel-type TPI of phase-randomized weak coherent pulses to compare the TPI effect with that of correlated photons. Further experiments were also performed with two temporally- and spatially separated weak coherent pulses. Although the observed interference results, including the results of visibility and fringe shape, can be suitably explained by classical intensity correlation, the physics underlying the TPI effect needs to be interpreted as the interference between the two-photon states at the single-photon level within the utilized interferometer. The results of this study can provide a more comprehensive understanding of the TPI of coherent light at the single-photon level.

Subject terms: Quantum optics, Quantum optics

Introduction

The observation of two-photon interference (TPI), particularly, the Hong–Ou–Mandel (HOM) effect1, is fundamental for understanding the superposition principle in quantum mechanics2, as well as for the development of photonic quantum information technologies such as linear optical quantum computing3, quantum communication4, and quantum metrology5. In general, the observation of the HOM effect via the superposition of two individual photons at a beam splitter is considered to be a highly reliable method for verifying the indistinguishability of distinct photons611. Subsequent to the seminal work by Hong, Ou, and Mandel, many TPI experiments have been extensively performed by employing highly correlated photon pairs, to study the fundamental physics underlying two-photon correlations and to explore quantum technologies12. The TPI effect is usually interpreted as the interference between the two indistinguishable two-photon amplitudes within the utilized interferometers. Among these, remarkable HOM-type TPI experiments have been performed by employing various types of input states such as two temporally separated photons13,14, the superposed state in polarizations and frequencies of input photons15,16, and two photons distributed in spatially separated paths17.

Meanwhile, HOM-type TPI experiments have been performed with classical light sources such as the weak coherent and fluorescent light beams for measurement of the coherence time and pulse width of ultrafast optical pulses, which are based on the second-order intensity-correlation and photon-coincidence counting techniques1820. Further studies have been performed to demonstrate classical analogue of the HOM effect and to simulate the quantum optical phenomena by using classical light sources2125. More recently, the measurement of high-visibility HOM fringes with weak coherent light at the single photon level has played a key role in the practical implementation of measurement-device-independent quantum key distribution protocols2631.

To date, most HOM-type TPI experiments with weak coherent states have been performed using the Mach–Zehnder and polarization-based Michelson interferometers by employing a phase randomization mechanism introduced in one of the interferometer arms3238. In this case, the TPI effect observed via coincidence measurement with two single-photon detectors (SPDs), even at the single-photon level, can also be described classically by intensity correlation. Consequently, the observed visibility bound of 0.5 has been particularly referred to emphasize the classical effect of the HOM-type TPI of coherent light. However, this approach based on intensity correlation does not consider the two-photon amplitudes contributing to the TPI effect at the single photon level. Moreover, when considering the intensity correlation, the observed interference-visibility does not change whatever the intensity involved in the experiment. In practice, the observed TPI-visibility shows the dependence of the mean-photon number in input state33,34. Therefore, the physics underlying the interference effect observed even with classical light needs to be understood in the quantum framework as it originate from the interference of the two indistinguishable two-photon amplitudes at the single-photon level.

In this context, in this paper, we report the experimental demonstrations of the TPI of weak coherent pulses. In particular, the HOM-type TPI experiment with phase-randomized weak coherent pulses is examined to compare the TPI effect at the single-photon level with that of correlated photons. We quantitatively analyze the results, including the single- and coincidence-counting rates, based on the statistical properties of the coherent state and the interference fringe originating from the two-photon state at the single-photon level. Moreover, further experiments with two temporally- and spatially separated weak coherent pulses are performed to emphasize the TPI resulting from the two-photon states within the utilized interferometer.

Results

Two-photon interference of weak coherent light

The coherent state of light is represented by the linear superposition of the photon-number states as

α=e-α22n=0αnn!n, 1

where n denotes the number of photons and α2=n the average photon number. Consequently, the probability of n photons being measured within a certain time interval is given by

Pn=nnn!e-n, 2

which represents the Poisson distribution. Upon considering the two weak coherent pulses, regardless of whether the two photons originate from two independent sources or from a common source (Fig. 1), the probability of simultaneously finding the number of photons n1 and n2 from the two pulses can be expressed as the product of the two corresponding probabilities. Owing to the statistical property of the coherent state, when the two pulses have the same mean photon number, the probability of simultaneously finding only one photon from each source is equal to the sum of the probabilities of finding two photons from only one source. Thus, we have

P1,1=P2,0+P0,2=n2e-2nforn1=n2=n. 3

Figure 1.

Figure 1

Two types of experimental schemes for realizing the two-photon interference of weak coherent pulses. The two photons contributing to the interference originate from (a) two independent sources or (b) a common source. BS, beam splitter; M, mirror; PZT, piezoelectric transducer; D, single-photon detector.

This relation implies that the two methods, shown in Fig. 1, for preparing weak coherent pulses for the TPI experiment are equivalent in terms of photon statistics except for the spectral property.

Here, we consider low-intensity coherent light to examine the TPI effect at the single-photon level. For a weak coherent pulse with mean photon number n, the ratio of Pn to Pn+1 as a function of n is given by Pn/Pn+1=n+1/n, which implies that the contribution of more than two photons in the TPI experiment can be ignored for very low values of mean photon number n. Figure 2 shows the statistical property of the weak coherent light: Fig. 2a shows photon-number distribution Pn of the coherent light as a function of the photon number with mean photon number n=0.01, whereas Fig. 2b shows the ratio of Pn to Pn+1 as a function of n. Under this condition, the ratios of P1/P2 and P2/P3 become 200 and 300, respectively. In our TPI experiment employing coincidence counting with two SPDs, the detection probability of one-photon component P1 was not considered, although an extremely large number of photons contributed to the single-photon counting events.

Figure 2.

Figure 2

(a) Photon-number distribution Pn of coherent light as a function of the number of photons with mean photon number n=0.01. (b) Ratio of Pn to Pn+1 as a function of n.

Here, we consider a Mach–Zehnder interferometer (MZI) to perform the TPI experiment with two weak coherent states α1 and α2, as shown in Fig. 1b, which corresponds to the standard setup for observing the HOM-type TPI by employing phase-randomized weak coherent light. Considering that the weak coherent pulse in the single-photon level incident on the MZI contains only two photons (n=2), two types of two-photon states are generated in the two interferometer arms. One corresponds to the case of two incoming photons traveling through common MZI path, which is similar to the path-entangled state formed with two single photons (or the N00N state with N=2, 2,0+0,2). The other corresponds to the case in which two photons travel separately through different MZI paths, 1,1. Consequently, the two-photon state within the MZI can be expressed as

Ψn=2=122102-ei2ϕ0122+121112, 4

where the subscripts indicate the two MZI paths and ϕ is the relative phase difference between the two paths. As is well known, the first term in Eq. (4) contributes to the highly phase-sensitive TPI similar to the case of the path-entangled two-photon states formed by two single photons. In contrast, the second term indicates phase-insensitive HOM interference. Here, the two photons in the path-correlated state contribute individually to the single-photon interference because each photon interferes only with itself and does not interfere with the other.

The single- and coincidence-counting rates, ND1/D2 and ND1&D2, respectively, as functions of the relative path-length difference Δx in the MZI are given by35

ND1/D2Δx=12ND1, max./D2, max.1±cosϕexp-12Δx2σ2, 5

and

ND1&D2Δx=ND1&D2, max.1-121+cos2ϕexp-Δx2σ2, 6

where ND1, max./D2, max. and ND1&D2, max. represent the maximum single and coincidence counting rates, respectively, ϕ=2πΔx/λ the relative phase difference between the two interferometer arms, and σ the Gaussian width of the fringe envelope. In particular, the TPI fringe corresponding to coincidence counting in Eq. (6) can be separated into two fringes as ND1&D2Δx=12ND1&D2, max.1-cos2ϕexp-Δx2σ2 and ND1&D2Δx=12ND1&D2, max.1-exp-Δx2σ2. Here, the former fringe results from the path-correlated state (N00N) and the latter from the two-photon state with two separated photons (HOM)39.

Figure 3 shows the one- and two-photon interference fringes of weak coherent pulses arising from the two-photon states expressed in Eq. (4). Here, we assumed a coherent pulse with a Gaussian-shaped spectral property (σ = 0.35 mm) and a center wavelength of 775 nm. From the Poisson distribution with n=2 and n=0.01 in Eq. (2), when the repetition rate of the weak coherent pulses is 20 MHz, the non-photon-number-resolving SPD at one of the MZI-output ports records the maximum number of counting events of 0.99 kHz, as shown in Fig. 3a,d. The TPI fringes shown in Fig. 3b,e include two distinct TPI fringes originating from the two two-photon states expressed in Eq. (4); thus, this fringe can be separated into two coexisting fringes, as shown in Fig. 3c. Although the two fringes cannot be extracted from a single measurement, these two events do not affect each other.

Figure 3.

Figure 3

One- and two-photon interference fringes with weak coherent light with detection probability of two-photon component P2 for mean photon number n=0.01. (a) One-photon interference fringes recorded at the two single-photon detectors D1 and D2. (b) Two-photon coincidence fringe composed of the fringes caused by the two two-photon states 2102-ei2ϕ0122 (N00N) and 1112 (HOM), as shown in (c). (df) Interference fringes for Δx0.

Here, the registered single- and coincidence-counting rates in Fig. 3a,b originate from the P2 contribution of only the input pulse for a given mean photon number n. Therefore, the average single and coincidence counting rates at the two SPDs D1 and D2 for the Δxxcoh. condition are given by

ND1/D2Δxxcoh.=ND1&D2Δxxcoh.=P22f=n24e-nf, 7

where f represents the repetition rate of the weak coherent pulses and xcoh. is the coherence length. However, the two SPDs record photons from both the P1 and P2 contributions, and the average single-counting rates for the Δxxcoh. condition are given by

ND1/D2Δxxcoh.=P1+P22f=142n+n2e-nf, 8

From the Poisson distribution in Eq. (2), we obtain P1=9.9×10-3 and P2=4.95×10-5 for n=0.01; therefore, the maximally observable single- and coincidence-counting rates for f=20MHz are calculated to be ND1, max./D2, max.198.99kHz and ND1&D2, max.0.495kHz, respectively.

Next, we consider a TPI experiment with phase-randomized weak coherent pulses. In this case, the relative phase relation between the two paths of the MZI in Fig. 1b needs to be randomized within a short length range by using a phase modulator or piezoelectric transducer (PZT) mounted on mirror M2. Consequently, the terms corresponding to the phase-sensitive interference fringes do not appear in Eqs. (5) and (6). Thus, the phase-insensitive HOM-type TPI fringe revealed only by coincidence counting can be expressed as

ND1&D2Δx=ND1&D2, max.1-12exp-Δx2σ2. 9

This equation indicates that the maximally observable TPI fringe visibility is limited to 0.5, because the two photons in the phase-sensitive path-correlated state are randomly divided between the two output ports of the MZI and consequently contribute to a constant coincidence regardless of the path-length difference. It is noteworthy that the interference effect and the fringe shape due to the 1112 state in Eq. (4) are identical to those of conventional HOM experiments with two time-correlated single photons, as shown in Fig. 3c.

Two-photon interference experiment with weak coherent pulses

We next consider weak coherent pulses at the single-photon level, wherein each pulse does not include more than two photons because the multiphoton contributions to the TPI fringe visibility can be effectively ignored under the experimental condition of a very low mean photon number n1. As mentioned above, the one-photon events per input pulse are not considered in the two-photon coincidence count, although a large number of photons contribute to the single-counting rates in the experiment.

Figure 4 shows the experimental setup used to observe the one-photon interference (OPI) and TPI fringes of weak coherent pulses. Single-mode fiber (SMF)-coupled weak coherent pulse trains are injected into the polarization-based Michelson interferometer shown in Fig. 4, which is equivalent to the MZI setup shown in Fig. 1b; however, the Michelson interferometer has an experimental facility for optical alignments to achieve spatial-mode overlap. Pulse-mode coherent light is generated in a mode-locked fiber laser with a 3.5 ps pulse duration at a 775 nm center wavelength and a 20 MHz repetition rate. The laser pulses are highly attenuated to the single-photon level by means of a variable neutral-density filter (VNDF) and subsequently coupled into a single-mode fiber. The interference filter (775-nm center-wavelength and 1-nm bandwidth) and linear polarizer are used to define the spectral and polarization properties, respectively. Two interfering coherent pulses are prepared using a half-wave plate (H1) with its axis oriented at 22.5° followed by a polarizing beam splitter (PBS1). Two quarter-wave plates (Qs) with their axes oriented at 45° are placed in the two interferometer arms to rotate the polarization direction. Thus, the two spatial modes (1 and 2) in Eq. (6) are defined based on the two polarization directions in this experiment employing the polarization-based Michelson interferometer. The second half-wave plate (H2) with its axis oriented at 22.5°, and PBS2 play the role of BS2 of the MZI shown in Fig. 1b. Two output photons are coupled to the SMF via coupling optics FC1 and FC2 and finally detected by SPDs D1 and D2.

Figure 4.

Figure 4

Experimental setup to observe the two-photon interference of weak coherent pulses. VNDF, variable neutral density filter; IF, interference filter; P, linear polarizer; H, half-wave plate; Q, quarter-wave plate; PBS, polarizing beam splitter; M, mirror; PZT, piezoelectric transducer; FC, Single-mode fiber coupler; D, single-photon detector; & coincidence counting circuit. Δx refers to the path-length difference between the two interferometer arms.

First, we examine the interference fringes and counting rates (Fig. 3). In our setup, to measure the OPI and TPI fringes of weak coherent pulses, path-length difference Δx between the two interferometer arms was adjusted by moving mirror M1, which was mounted on a motorized translation stage. Figure 5 shows the measured OPI and TPI fringes as a function of path-length difference Δx. Upon adjusting the VNDF, we estimated the average single (ND1 and ND2)- and coincidence (ND1&D2)-counting rates at SPDs D1 and D2 as ~ 300 kHz and ~ 4.5 kHz (Fig. 5a,b, respectively) for a large path-length-mismatch condition (Δxxcoh.). Here, the measured single-counting rates in Fig. 5a,c originate from both P1 and P2 of the input pulse for a given mean photon number n. In contrast, the coincidence-counting rate in Fig. 5b,d can originate only from P2. Assuming ideal conditions (lossless optical system and SPDs with unity detection efficiency), n is estimated to be ~ 0.0305. Moreover, for weak coherent light, all coincidence-counting events are caused by accidental coincidences within the resolving time35. Therefore, the coincidence can be straightforwardly calculated using two single-counting events as ND1&D2=ND1ND2/f. Here, the single-counting events (ND1 and ND2) include the photons that originate from both the P1 and P2 contributions of the input pulse. The fringe visibilities observed in the single-counting rates are 0.94 ± 0.01 and 0.99 ± 0.01, as estimated from the observed fringes at Δx0, as shown in Fig. 5c. The full-width at half maximum (FWHM) value of the fringe envelope is estimated to be ~ 0.94 mm, which is determined by the interference filter used in the experiment.

Figure 5.

Figure 5

One- and two-photon interference fringes of weak coherent pulses. (a) Single (ND1, ND2)- and (b) coincidence (ND1&D2)-counting rates as functions of path-length difference Δx (step size of 2 μm). (c,d) Interference fringes measured at Δx0.

Meanwhile, the TPI fringe is simultaneously observed in coincidence counting, as shown in Fig. 5b. As mentioned above, the observed TPI fringe includes two kinds of TPI fringes: the N00N-state fringe due to the path-correlated two-photon state and the HOM fringe due to the two photons separated along the two interferometer arms, as indicated in Eq. (4) and Fig. 3c. For the exact estimation of the TPI fringe shape and visibility, it is necessary to recall that the TPI fringe of weak coherent light is fully expressed by the accidental coincidence-counting rates as a function of the path-length difference35, ND1Δx×ND2Δx/f. Therefore, the TPI fringe in Eq. (6) can be expressed as

ND1&D2Δx=ND1&D2, max.1+V1-V2cosϕexp-12Δx2σ2-12V1V21+cos2ϕexp-Δx2σ2, 10

where V1 and V2 represent the fringe visibilities observed for the single-counting rates, as shown in Fig. 5c. For V1=V2, Eq. (10) reduces to Eq. (6). From the theoretical fit to the data points in Fig. 5d, V1 and V2 were found to be 0.95 ± 0.01 and 0.99 ± 0.01, respectively, which agree well with the values in Fig. 5c. This result clearly shows that the TPI of weak coherent light should be interpreted by means of the two-photon state in the single-photon picture rather than the classical intensity correlation. The FWHM of the TPI-fringe envelope was estimated to be ~ 0.58 mm, which is 1/2 times narrower than that of the OPI fringe.

Next, we examined the case in which the relative phase between the two weak coherent pulses was randomized. To observe the phase-insensitive HOM-type TPI fringe, path-length difference Δx is introduced by moving mirror M1, while mirror M2 is affixed to the PZT actuator to randomize the relative phase between the two paths. Phase randomization was originally introduced to ensure that the experimental setup in Fig. 1b is equivalent to that in Fig. 1a, which can effectively make the phase-sensitive interference of two photons in the path-correlated state disappear in the single-and coincidence-counting rates shown in Fig. 3a,c, respectively. Therefore, the oscillatory fringes are invisible in single and coincidence counts, as shown in Fig. 5a,c, as well as the coincidence counts in Fig. 5b,d. Figure 6 shows the experimental TPI results of the phase-randomized weak coherent pulses. The HOM-dip-like TPI fringe with only the 1112 state is shown in Fig. 6b. From the theoretical fitting, the coincidence-dip fringe visibility and FWHM are found to be 0.48 ± 0.01 and 0.57 ± 0.01 mm, respectively.

Figure 6.

Figure 6

(a) Single (ND1, ND2)- and (b) coincidence (ND1&D2)-counting rates as functions of the path-length difference when the interferometer arms are phase-randomized.

Two-photon interference of temporally separated weak coherent pulses in a phase-randomized interferometer

Nest we consider two temporally well-separated weak coherent pulses at the single-photon level, wherein each pulse does not include more than two photons. When two such sequential weak coherent pulses are incident on the MZI shown in Fig. 1b or the polarization-based Michelson interferometer shown in Fig. 4, a pairwise two-photon state contributing to the HOM effect can be generated within the two interferometer arms. Here, we ignore the case in which two sequential pulses traverse the same path because this two-photon state does not contribute to the TPI in a phase-randomized interferometer. In this regard, it has been recently demonstrated that the pairwise two-photon state with two temporally separated weak coherent photons yields the same HOM fringe as that with the conventional two-photon state32. In this work, we performed a HOM-type TPI experiment by employing temporal post-selection by adjusting the coincidence time window in comparison with the temporal separation between sequential pulses. For this purpose, two sequential weak coherent pulses as input two-photon states were prepared with orthogonal polarizations, Ψ=a^Ha^VΔtαH,αV.

Figure 7 shows the experimental setup in this case. Two temporally separated weak coherent pulses are prepared before their incidence on the phase-randomized interferometer by using an optical delay line, and the selective coincidence counting of the separated pulses is performed by introducing an electrical delay line after one of the SPDs. In our experiment, the optical delay time (Δt) between sequential pulses was fixed at 8 ns, which corresponds to an optical delay of 2.4 m in free space. The electrical delay time (Δτd) and coincidence time window (TR) were set to (0 ns, 8 ns) and (4 ns, 10 ns), respectively, for the post-selection of the interfering two-photon states. The pairwise two-photon state related to the HOM interference is generated through the two optical paths of the polarization-based Michelson interferometer as a^Ha^VΔt1/2a^1,Ha^2,VΔt-a^2,Va^1,HΔt. The operating principle of the interferometer is the same as that in Fig. 4, except for the temporal separation between the two photons contributing to the TPI.

Figure 7.

Figure 7

Experimental setup to observe the two-photon interference of temporally separated weak coherent pulses. Temporal separation between two sequential pulses is introduced by applying an optical delay, and the temporal post-selection of the interfering two-photon states is performed by the application of an electrical delay (Δτd) and a variable coincidence time window. Δx is used for varying the path-length difference between the two interferometer arms to observe interference fringes.

Figure 8 shows the experimental results for single- and coincidence-counting rates as functions of path-length difference Δx. For Δτd = 0 and TR = 4 ns, the two SPDs measure two photons in the same pulse, and the coincidence-counting circuit records the TPI fringes caused by each pulse. Therefore, the same TPI fringe as in Fig. 6b is observed; however, but the coincidence-counting rate is decreased by half for the same condition of the single-counting rates, as shown in Fig. 8a,b. This is because the corresponding coincidence-counting rate is given by ND1&D2Δxxcoh.=P2/2×2f, where P2=n/22/2×e-n/2. In contrast, for Δτd = 8 ns and TR = 4 ns, the TPI fringe of the pairwise two-photon state can be observed by temporal post-selection in the coincidence-counting circuit. Under this condition, each SPD detects only one photon in each pulse, and the coincidence-counting rate is decreased by one quarter. In this case, the coincidence-counting event arises from P1,1Δt=P1P1Δt, where P1=P1Δt=n/2×e-n/2 as expressed in Eq. (3). Therefore, the corresponding coincidence-counting rate is given by ND1&D2Δxxcoh.=P1P1Δt/4×f, and the HOM fringe shows coincidence-peak pattern instead of a dip, because the two photons traversing the two interferometer arms are distinguishable in terms of polarization in a given temporal mode. To confirm the temporal post-selection for the observation of the TPI fringe of the pairwise two-photon state, we chose a wider coincidence-counting window than the temporal separation of the sequential pulses (TR = 10 ns). In this case, the coincidence-counting circuit records the two TPI fringes simultaneously, as shown in Fig. 8b. The resulting coincidence is given by 2P2f or n/22e-n/2f, and the interference fringe does not vary with the path-length difference.

Figure 8.

Figure 8

Single (ND1, ND2)- and coincidence (ND1&D2)-counting rates as functions of the path-length difference for two temporally separated input photons (Δt = 8 ns). (a,b) Measurements were performed with (Δτd = 8 ns) and without (Δτd = 0) temporal filtering for a coincidence resolving time window of TR = 4 ns. (c,d) Measurements were performed with Δτd = 8 ns and TR = 10 ns.

Two-photon interference of spatially separated weak coherent pulses in two phase-randomized interferometers

Figure 9 shows the experimental setup used to observe the HOM-type TPI of two spatially separated weak coherent pulses, which were prepared using a beam splitter (BS0) followed by a pair of balanced MZIs. In our experiment, we considered the case where only one photon traverses each MZI to show that the TPI effect originates from the two-photon state at the single-photon level and, consequently, is observed via coincidence detection by SPDs D1 and D3 and D2 and D3. Here, the phase shifter (PS) is a thin glass plate with a thickness of ~ 0.2 mm, which is used to introduce a small optical path delay in one of the four interferometer arms. The two PZTs are used to eliminate the OPI corresponding to the single-counting rate by introducing phase randomization. The two output photons from the interferometers are coupled to SMF couplers and finally detected by SPDs to register single and coincidence counts in the counting electronics.

Figure 9.

Figure 9

Experimental setup to observe the two-photon interference of spatially separated weak coherent pulses (WCPs). Two balanced Mach–Zehnder interferometers are positioned after a beam splitter (BS0). BS, 50:50 beam splitter; PS, phase shifter; D, single-photon detector. Phase randomization is synchronously performed by the two PZTs, and Δx1 and Δx2 simultaneously introduce path-length differences between the two interferometer arms in the two spatially separated interferometers.

In this experiment, the necessary conditions for the observation of the HOM-type fringe are the synchronization of the phase randomization and simultaneous change in path-length differences Δx1 and Δx2 in the two interferometers. In actual experiments, to realize these technical requirements, the two balanced MZIs are constructed of a single polarization-based Michelson interferometer, in which the two optical paths for the spatially separated individual interferometers share common optical components, such as mirrors, wave plates, and polarizing beam splitters.

The experimental results demonstrating the HOM-type TPI effect observed with the two spatially separated interferometers are shown in Fig. 10. The two data sets corresponding to each two-fold coincidence counting with two detectors D1 and D3 and D2 and D3, are obtained simultaneously. During the experiment, the single-counting rates in all the SPDs were maintained constant with varying path-length differences. In the figures, the filled squares, diamonds, and circles correspond to the phase shifts of Δϕ=0, Δϕ=π/2, and Δϕ=π, respectively, and the solid lines represent the theoretical curve fits. From the curve fitting, the HOM-fringe visibilities were obtained to be V13 = 0.48 ± 0.01 and V23 = 0.48 ± 0.01 for Δϕ=0 and Δϕ=π, respectively. For Δϕ=π/2, we could not observe any fringe pattern as the path length was varied. As shown in Fig. 10, there is a transition between the HOM peak and dip fringes according to the relative phase between the two amplitudes. For Δx=0 in Fig. 10a, the coincidence counting rate as a function of the rotation angle (θ) of the thin glass plate is given by ND1&D3θ=ND1&D3,1+V13cos2π/λd-t, where ND1&D3, denotes the coincidences for Δxxcoh. and λ the center wavelength (see the insets in Fig. 10a,b). The increase in path-length difference d with an increase in θ can be expressed as d=t/cossin-1n0sinθ/n, where t denotes the thickness of the glass and n0n is the refractive index of air (glass).

Figure 10.

Figure 10

Experimental results relating to the two-photon interference of spatially separated weak coherent pulses. Coincidences are measured with two detectors (a) D1 and D3, and (b) D2 and D3 as functions of path-length difference Δx=Δx1+Δx2 for two spatially separated input photons. Coincidence fringes for each combination of the two detectors are obtained with a relative phase shift between the two two-photon amplitudes. Insets in (a) and (b) indicate the coincidence counts measured as functions of the rotation angle of the thin glass plate, which introduces an additional relative phase shift between the two interfering amplitudes.

To comprehensively understand the experimental results, it is helpful to consider the two-photon amplitudes in both the spatially separated MZIs and the conventional single MZI shown in Fig. 1b. In our experiment, it is assumed that the phase randomization in the two MZIs is actively synchronized by the two PZTs and path-length differences Δx1 and Δx2 that are simultaneously introduced as Δx=Δx1+Δx2, with Δx1=Δx2. In this case, the two interfering two-photon amplitudes, contributing to the HOM-type TPI, can be considered as two pairs of amplitudes along four separated paths, which correspond to a^a1a^b2BS2a^D1a^D3 and a^a2a^b1BS2a^D1a^D3. We note here that the coincidence events by the two-photon amplitudes a^a1a^a2 and a^b1a^b2 do not afford the TPI fringe, because the synchronized phase randomizations by the two PZTs are performed in paths a1 and a2 of the two MZIs. Consequently, the phase-insensitive HOM-type TPI fringe is only observed without the introduction of any relative phase relation between the two amplitudes a^a1a^b2 and a^a2a^b1. However, if we introduce an additional phase shift Δϕ in one of the four paths (for example, path b2), the measured coincidences reveal an oscillation between the HOM peak and dip fringes as a function of the phase shift, as shown in Fig. 10.

Next, we consider the case in which the two interfering two-photon amplitudes corresponding to Fig. 9 overlap in the two paths of the single MZI (a1=a2=a, b1=b2=b, and Δx1=Δx2=Δx) shown in Fig. 1b. In this case, the two-photon amplitudes contributing to coincidence detection by SPDs D1 and D2 should be considered including BS2, that is, a^aa^bBS2(t-t)a^D1a^D2 and a^aa^bBS2(r-r)a^D1a^D2, where t and r denote the transmission and reflection of the two photons at BS2, respectively. Indeed, the conventional single MZI scheme corresponds to a folded version of that shown in Fig. 9. As a result, to observe the HOM-type TPI of weak coherent light in two spatially separated MZIs, it is necessary to satisfy the experimental conditions in such a manner that the two-photon amplitudes in a single MZI contribute to the observation of the HOM interference. Although the observed HOM-type TPI fringe with the two spatially separated MZIs can be fully explained by the classical intensity correlation with respect to the limited maximum visibility of 0.5 and the fringe shape, the interference effect including the coincidence-counting rate and the related two-photon state may need to be understood as a consequence of the two-photon correlation at the single-photon level or the interference of two indistinguishable two-photon amplitudes.

Discussion

The TPI of highly correlated photon pairs is interpreted as the interference between the two indistinguishable two-photon amplitudes within the utilized interferometers. When the similar experiment is performed by employing weak coherent light at the single photon level, the physics underlying the interference effect needs to be understood in the quantum framework as it originate from the interference of the two indistinguishable two-photon amplitudes at the single-photon level. In this context, we experimentally demonstrated the observation of the TPI of weak coherent pulses and quantitatively analyzed the experimental results considering the single- and coincidence-counting rates based on the statistical property of the coherent state and the interference fringe originating from the two-photon state at the single-photon level. In particular, the HOM-type TPI experiment was performed by employing a phase-randomization mechanism, and further experiments were performed utilizing two temporally- and spatially separated weak coherent pulses.

From the statistical property of the coherent light with a very low mean photon-number n0.03, we clearly confirmed in the experiments that the observed TPI fringe corresponding to the coincidence-counting events with varying path-length differences originated from the two-photon component in the input pulse. The observed TPI fringe shape and visibility can also be explained by multiplying the two single-photon counting events; in this case, the result is similar to the classical TPI fringe given by the classical intensity correlation function. Moreover, we showed that the HOM-type TPI fringe visibility is limited to 0.5 owing to the path-correlated two-photon state that does not contribute to the interference fringe but only to the random coincidence-counting event caused by the active phase-randomization mechanism.

When the two input photons contributing to the TPI are temporally and spatially well-separated, the observed TPI is more clearly explained by the two two-photon amplitudes formed with separated weak coherent pulses at the single-photon level. According to Dirac’s famous statement on single-photon interference40, and its two-photon analogy41, if each single-photon or photon-pair interferes only with itself, then individual single photons contributing to the TPI do not necessarily have to travel through a common interferometer with spatiotemporal overlap. In other words, individual photons can separately traverse the interferometer arms to exhibit TPI via the coincidence measurement of two single-photon counting events. For the TPI experiment with weak coherent pulses traveling through the two spatially separated MZIs, when the interferometric scheme is configured in such a manner that the two interfering photons traverse as if through a common interferometer, the observed TPI fringe shows the same feature as the fringe obtained in the single-MZI scheme, except for an additional phase shift introduced into the interfering two-photon states. As a result, the observed TPI fringe shows HOM-type bunching and splitting depending on the relative phase shift between the two two-photon amplitudes contributing to the interference effect.

Although the TPI of weak coherent light, especially the fringe shape and visibility bound, can be described classically by intensity correlation, we emphasize that the observed interference effect should be considered as the interference between two alternative two-photon states constituted in the two interferometer arms when we consider the weak coherent pulse at the single-photon level. We believe that our results can provide more comprehensive understanding of the TPI of weak coherent light at the single-photon level.

Acknowledgements

This work was supported by the National Research Foundation of Korea (NRF) (Nos. 2021R1A2B5B03002377, 2020M3E4A1080030 and 2020R1I1A1A01072979) and the Ministry of Science and ICT (MSIT), Korea, under the Information Technology Research Center (ITRC) support program (IITP-2021-2020-0-01606) supervised by the Institute of Information & Communications Technology Planning & Evaluation (IITP). This work was also supported in part under the research program (Nos. 2019-106 and 2020-081) by the affiliated institute of ETRI.

Author contributions

H.K., O.K. and H.S.M. conceived the project. H.K. designed the experimental setup and performed the experiments. H.K., O.K. and H.S.M. discussed the results and contributed to the writing of the manuscript.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Hong CK, Ou ZY, Mandel L. Measurement of subpicosecond time intervals between two photons by interference. Phys. Rev. Lett. 1987;59:2044–2046. doi: 10.1103/PhysRevLett.59.2044. [DOI] [PubMed] [Google Scholar]
  • 2.Greenberger DM, Horne MA, Zeilinger A. Multiparticle interferometry and the superposition principle. Phys. Today. 1993;46:22–29. doi: 10.1063/1.881360. [DOI] [Google Scholar]
  • 3.Kok P, Munro WJ, Nemoto K, Dowling JP, Milburn GJ. Linear optical quantum computing with photonic qubits. Rev. Mod. Phys. 2007;79:135–174. doi: 10.1103/RevModPhys.79.135. [DOI] [Google Scholar]
  • 4.Yuan ZS, et al. Entangled photons and quantum communication. Phys. Rep. 2010;497:1–40. doi: 10.1016/j.physrep.2010.07.004. [DOI] [Google Scholar]
  • 5.Dowling JP. Quantum optical metrology-the lowdown on high-N00N states. Contemp. Phys. 2008;49:125–143. doi: 10.1080/00107510802091298. [DOI] [Google Scholar]
  • 6.Kaltenbaek R, Blauensteiner B, Żukowski M, Aspelmeyer M, Zeilinger A. Experimental interference of independent photons. Phys. Rev. Lett. 2006;96:240502. doi: 10.1103/PhysRevLett.96.240502. [DOI] [PubMed] [Google Scholar]
  • 7.Sanaka K, Pawlis A, Ladd TD, Lischka K, Yamamoto Y. Indistinguishable photons from independent semiconductor nanostructures. Phys. Rev. Lett. 2009;103:053601. doi: 10.1103/PhysRevLett.103.053601. [DOI] [PubMed] [Google Scholar]
  • 8.Lettow R, et al. Quantum interference of tunably indistinguishable photons from remote organic molecules. Phys. Rev. Lett. 2010;104:123605. doi: 10.1103/PhysRevLett.104.123605. [DOI] [PubMed] [Google Scholar]
  • 9.Sipahigil A, et al. Quantum interference of single photons from remote nitrogen-vacancy centers in diamond. Phys. Rev. Lett. 2012;108:143601. doi: 10.1103/PhysRevLett.108.143601. [DOI] [PubMed] [Google Scholar]
  • 10.Toyoda K, Hiji R, Noguchi A, Urabe S. Hong–Ou–Mandel interference of two phonons in trapped ions. Nature. 2015;527:74–77. doi: 10.1038/nature15735. [DOI] [PubMed] [Google Scholar]
  • 11.Li J, et al. Hong–Ou–Mandel interference between two deterministic collective excitations in an atomic ensemble. Phys. Rev. Lett. 2016;117:180501. doi: 10.1103/PhysRevLett.117.180501. [DOI] [PubMed] [Google Scholar]
  • 12.Bouchard F, et al. Two-photon interference: The Hong–Ou–Mandel effect. Rep. Prog. Phys. 2021;84:012402. doi: 10.1088/1361-6633/abcd7a. [DOI] [PubMed] [Google Scholar]
  • 13.Pittman TB, et al. Can two-photon interference be considered the interference of two photons? Phys. Rev. Lett. 1996;77:1917–1920. doi: 10.1103/PhysRevLett.77.1917. [DOI] [PubMed] [Google Scholar]
  • 14.Kim H, Lee SM, Moon HS. Two-photon interference of temporally separated photons. Sci. Rep. 2016;6:34805. doi: 10.1038/srep34805. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Kim H, Lee HJ, Lee SM, Moon HS. Highly efficient source for frequency-entangled photon pairs generated in a 3rd-order periodically poled MgO-doped stoichiometric LiTaO3 crystal. Opt. Lett. 2015;40:3061–3064. doi: 10.1364/OL.40.003061. [DOI] [PubMed] [Google Scholar]
  • 16.Kim H, Lee SM, Kwon O, Moon HS. Two-photon interference of polarization-entangled photons in a Franson interferometer. Sci. Rep. 2017;7:5772. doi: 10.1038/s41598-017-06196-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Kim H, Lee SM, Moon HS. Generalized quantum interference of correlated photon pairs. Sci. Rep. 2015;5:9931. doi: 10.1038/srep09931. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Ou ZY, Gage EC, Magill BE, Mandel L. Fourth-order interference technique for determining the coherence time of a light beam. J. Opt. Soc. Am. B. 1989;6:100–103. doi: 10.1364/JOSAB.6.000100. [DOI] [Google Scholar]
  • 19.Miyamoto Y, Kuga T, Baba M, Matsuoka M. Measurement of ultrafast optical pulses with two-photon interference. Opt. Lett. 1993;18:900–902. doi: 10.1364/OL.18.000900. [DOI] [PubMed] [Google Scholar]
  • 20.Baba M, Li Y, Matsuoka M. Intensity interference of ultrashort pulsed fluorescence. Phys. Rev. Lett. 1996;76:4697–4700. doi: 10.1103/PhysRevLett.76.4697. [DOI] [PubMed] [Google Scholar]
  • 21.Kaltenbaek R, Lavoie J, Resch KJ. Classical analogues of two-photon quantum interference. Phys. Rev. Lett. 2009;102:243601. doi: 10.1103/PhysRevLett.102.243601. [DOI] [PubMed] [Google Scholar]
  • 22.Kaltenbaek R, Lavoie J, Biggerstaff DN, Resch KJ. Quantum-inspired interferometry with chirped laser pulses. Nat. Phys. 2008;4:864–868. doi: 10.1038/nphys1093. [DOI] [Google Scholar]
  • 23.Ogawa K, Tamate S, Kobayashi H, Nakanishi T, Kitano M. Time-reversed two-photon interferometry for phase superresolution. Phys. Rev. A. 2013;88:063813. doi: 10.1103/PhysRevA.88.063813. [DOI] [Google Scholar]
  • 24.Ogawa K, Tamate S, Nakanishi T, Kobayashi H, Kitano M. Classical realization of dispersion cancellation by time-reversal method. Phys. Rev. A. 2015;91:013846. doi: 10.1103/PhysRevA.91.013846. [DOI] [Google Scholar]
  • 25.Ogawa K, Kobayashi H, Tomita A. Classical reconstruction of interference patterns of position-wave-vector–entangled photon pairs by the time-reversal method. Phys. Rev. A. 2018;97:023823. doi: 10.1103/PhysRevA.97.023823. [DOI] [Google Scholar]
  • 26.Lo HK, Curty M, Qi B. Measurement-device-independent quantum key distribution. Phys. Rev. Lett. 2012;108:130503. doi: 10.1103/PhysRevLett.108.130503. [DOI] [PubMed] [Google Scholar]
  • 27.Ferreira da Silva T, et al. Proof-of-principle demonstration of measurement-device-independent quantum key distribution using polarization qubits. Phys. Rev. A. 2013;88:052303. doi: 10.1103/PhysRevA.88.052303. [DOI] [Google Scholar]
  • 28.Ferreira da Silva T, Vitoreti D, Xavier GB, Temporão GP, von der Weid JP. Long-distance Bell-state analysis of fully independent polarization weak coherent states. J. Lightwave Technol. 2013;31:2881–2887. doi: 10.1109/JLT.2013.2274615. [DOI] [Google Scholar]
  • 29.Yuan ZL, et al. Interference of short optical pulses from independent gain-switched laser diodes for quantum secure communications. Phys. Rev. Appl. 2014;2:06406. doi: 10.1103/PhysRevApplied.2.064006. [DOI] [Google Scholar]
  • 30.Agnesi C, et al. Hong–Ou–Mandel interference between independent III–V on silicon waveguide integrated lasers. Opt. Lett. 2019;44:271–274. doi: 10.1364/OL.44.000271. [DOI] [PubMed] [Google Scholar]
  • 31.Semenenko H, Sibson P, Thompson MG, Erven C. Interference between independent photonic integrated devices for quantum key distribution. Opt. Lett. 2019;44:275–278. doi: 10.1364/OL.44.000275. [DOI] [PubMed] [Google Scholar]
  • 32.Kim H, Lee SM, Kwon O, Moon HS. Observation of two-photon interference effect with a single non-photon-number resolving detector. Opt. Lett. 2017;42:2443–2446. doi: 10.1364/OL.42.002443. [DOI] [PubMed] [Google Scholar]
  • 33.Chen H, et al. Hong–Ou–Mandel interference with two independent weak coherent states. Chin. Phys. B. 2016;25:020305. doi: 10.1088/1674-1056/25/2/020305. [DOI] [Google Scholar]
  • 34.Moschandreou E, et al. Experimental study of Hong–Ou–Mandel interference using independent phase randomized weak coherent states. J. Lightwave Technol. 2018;36:3752–3759. doi: 10.1109/JLT.2018.2850282. [DOI] [Google Scholar]
  • 35.Kim H, Kwon O, Moon HS. Experimental interference of uncorrelated photons. Sci. Rep. 2019;9:18375. doi: 10.1038/s41598-019-54504-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Arruda FZM, Mahdavifar M, Krop T, Souto Ribeiro PH, Rafsanjani SMH. Observation of two-photon coalescence in weak coherent wave packets. J. Opt. Soc. Am. B. 2020;37:2901–2905. doi: 10.1364/JOSAB.397209. [DOI] [Google Scholar]
  • 37.Kim D, Park J, Jeong T, Kim H, Moon HS. Two-photon interference between continuous-wave coherent photons temporally separated by a day. Photonics Res. 2020;8:338–342. doi: 10.1364/PRJ.376993. [DOI] [Google Scholar]
  • 38.Kim H, Kim D, Park J, Moon HS. Hong–Ou–Mandel interference of two independent continuous-wave coherent photons. Photonics Res. 2020;8:1491–1495. doi: 10.1364/PRJ.393246. [DOI] [Google Scholar]
  • 39.Halder M, et al. Photon-bunching measurement after two 25-km-long optical fibers. Phys. Rev. A. 2005;71:042335. doi: 10.1103/PhysRevA.71.042335. [DOI] [Google Scholar]
  • 40.Dirac PAM. The Principles of Quantum Mechanics. 4. Oxford University; 1958. [Google Scholar]
  • 41.Ou, Z. Y. Investigation of nonclassical and nonlocal effects in fourth-order interference, Ph.D. thesis, University of Rochester (1990).

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES