Abstract

TFET based label-free biosensors are fast, sensitive and more power efficient as compared to CMOS biosensors, which are prone to short channel effects (SCEs). However, literature is flooded with various TFET biosensors that have become the reason of dilemma for researchers during pandemic situations like COVID-19. Therefore, in this work, a physically doped (PD), charge plasma (CP) and electrically doped (ED) dielectric modulated (DM) TFET based label-free biosensors are compared, which cover almost the entire range of doping and junctionless devices. Also, we found that the ED based TFET biosensors provide better current sensitivities of 5.10 × 107, 4.77 × 108 and 7.11 × 108 for biomolecules with K=12, positive charge= 1 × 1013 C/cm2 and negative charge= -1 × 1013 C/cm2 respectively. Hence, ED-DM-TFET based biosensors can act as promising candidates to provide better detection and identification quality.

Keywords: TFET, Biosensor, Physically doped (PD), Charge plasma (CP), Electrically doped (ED)

Author Contributions

All the authors have contributed to the design, investigation, conceptualization and formal analysis. and design. Author Arpita Biswas prepared the first draft of the manuscript after perfroming the simulation study and validation. Author Chithraja Rajan edited the manuscript after data analysis and validation. D P Samajdar commented on the manuscript and supervised the entire work. All the authors read and approved the final version of the manuscript.

Data Availability

Not applicable.

Code Availability

Not Applicable.

Declarations

Consent to Participate

All the authors contributed voluntarily to this work.

Consent for Publication

In accordance with the copyright transfer or open access rules.

Conflict of Interest

The authors declare that they have no conflict of interest. 

Ethics Approval

Not Applicable.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Arpita Biswas, Email: arpitabiswas18919@gmail.com.

Chithraja Rajan, Email: rajan.chithraja@gmail.com.

Dip Prakash Samajdar, Email: dipprakash010@gmail.com.

References

  • 1.Drosten C, Drosten S, Preiser W, Werf SVD, Brodt HR, Becker S. Identification of a novel coronavirus in patients with severe acute respiratory syndrome. N Engl J Med. 2003;348(20):1967–1976. doi: 10.1056/NEJMoa030747. [DOI] [PubMed] [Google Scholar]
  • 2.Ali M, Zaki SV, Boheemen TM, Bestebroer ADME, Osterhau, Ron AM, Fouchier Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia. N Engl J Med. 2012;367(19):1814–1820. doi: 10.1056/NEJMoa1211721. [DOI] [PubMed] [Google Scholar]
  • 3.Fuk-Woo Chan J, Yuan S, Kok K-H, Kai-Wang K, To H, Chu J, Yang FX, et al. A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster. Lancet. 2020;395(10223):514–523. doi: 10.1016/S0140-6736(20)30154-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Priyadarshi K, Nag VL, Kombade SP, Gadepalli RS, Misra S, Singh K. Molecular diagnosis of COVID-19: an update and review. Ann Natl Acad Med Sci (India) 2020;3:126–137. [Google Scholar]
  • 5.Kalra S, Kumar MJ, Dhawan A. Reconfigurable FET biosensor for a wide detection range and electrostatically tunable sensing response. IEEE Sens J. 2019;20(5):2261. doi: 10.1109/JSEN.2019.2952333. [DOI] [Google Scholar]
  • 6.Gandhi R, Chen Z, Singh N, Banerjee K 2011 Vertical Si-nanowire n-type tunneling FETs with low subthreshold swing (≤= 50 mV/decade) at room temperature,. IEEE Electron Device Letters 32(4):437-439. 10.1109/LED.2011.2106757
  • 7.Dixit A, Samajdar DP, Chauhan V (2021) Sensitivity Analysis of a Novel Negative Capacitance FinFET for Label-Free Biosensing IEEE Transactions on Electron Devices. 68(10):5204–5210. 10.1109/TED.2021.3107368
  • 8.Rajan C, Samajdar DP. Design principles for a novel lightweight configurable PUF using a reconfigurable FET. IEEE Trans Electron Devices. 2020;67(12):5797–5803. doi: 10.1109/TED.2020.3030868. [DOI] [Google Scholar]
  • 9.Saha P, Dash DK, Sarkar SK (2019) Nanowire reconfigurable FET as biosensor: Based on dielectric modulation approach. Solid-State Electron 161. 10.1016/j.sse.2019.107637
  • 10.Ghosh C, Dwivedi SMMD, Ghosh A, Dalal A, Mondal A. A novel Ag nanoparticles/TiO 2 nanowires-based photodetector and glucose concentration detection. Appl Phys A. 2019;125(12):1–9. doi: 10.1007/s00339-019-3108-5. [DOI] [Google Scholar]
  • 11.Dwivedi SMMD, Ghosh A, Deepthy S, Maji M, Lahiri R, Mondal S, Ghosh C, Dalal A, Mondal A, Ghosh M (2020) Detection technique for vitamin D 3 using Er-doped TiO 2 nanowire-based UV photodetector. J Nanophotonics 14(4):046001. 10.1117/1.JNP.14.046001
  • 12.Thanihaichelvan MSN, Surendran T, Kumanan U, Sutharsini P, Ravirajan R, Valluvanhhi T, Tharsika (2021) Selective and electronic detection of COVID-19 (Coronavirus) using carbon nanotube field effect transistor-based biosensor: A proof-of-concept study. Mater Today: Proc. 10.1016/j.matpr.2021.05.011 [DOI] [PMC free article] [PubMed]
  • 13.Yadav S, Gedam A, Tirkey S (2020) A dielectric modulated biosensor for SARS-CoV-2. IEEE Sens J. 10.1109/JSEN.2020.3019036
  • 14.Seo G, Lee G, Kim MJ, Baek S-H, Choi M, Ku KB, Lee C-S, et al. Rapid detection of COVID-19 causative virus (SARS-CoV-2) in human nasopharyngeal swab specimens using field-effect transistor-based biosensor. ACS Nano. 2020;14(4):5135–5142. doi: 10.1021/acsnano.0c02823. [DOI] [PubMed] [Google Scholar]
  • 15.Fathi-Hafshejani P, Azam N, Wang L, Kuroda MA, Hamilton MC, Hasim S, Mahjouri-Samani M (2021)Two-dimensional-material-basedfield-effect transistor biosensor for detecting COVID-19 virus (SARS-CoV-2). ACS Nano 15(7):11461–11469 [DOI] [PubMed]
  • 16.Verma M, Tirkey S, Yadav S, Sharma D, Yadav DS. Performance assessment of a novel vertical dielectrically modulated TFETbased biosensor. IEEE Trans Electron Devices. 2017;64(9):3841–3848. doi: 10.1109/TED.2017.2732820. [DOI] [Google Scholar]
  • 17.Agnihotri SK, Samajdar DP, Rajan C, Yadav AS, Gnanesh G (2020) Performance analysis of gate engineered dielectrically modulated TFET biosensors. Int J Electron :1–16. 10.1080/00207217.2020.1793407
  • 18.Lodhi A, Rajan C, Behera AK, Samajdar DP, Soni D, Yadav DS. Sensitivity and sensing speed analysis of extended nano-cavity and source over electrode in Si/SiGe based TFET biosensor. Appl Phys A. 2020;126(11):1–8. doi: 10.1007/s00339-020-04008-0. [DOI] [Google Scholar]
  • 19.Soni D, Sharma D (2019) Design of NW TFET biosensor for enhanced sensitivity and sensing speed by using cavity extension and additional source electrode. Micro Nano Lett 14(8):901-905. 10.1049/mnl.2018.5733
  • 20.Mahalaxmi M, Acharya B, Mishra GP (2020) Design and analysis of dual-metal-gatedouble-cavitycharge-plasma-TFET as a label free biosensor. IEEE Sens J 20(23):13969-13975. 10.1109/JSEN.2020.2979016
  • 21.Singh D, Pandey S, Nigam K, Sharma D, Yadav DS, Kondekar P. A charge-plasma-baseddielectric-modulated junctionless TFET for biosensor label-free detection. IEEE Trans Electron Devices. 2016;64(1):271. doi: 10.1109/TED.2016.2622403. [DOI] [Google Scholar]
  • 22.Yadav S, Madhukar R, Sharma D, Aslam M, Soni D, Sharma N (2018) A new structure of electrically doped TFET for improving electronic characteristics. Appl Phys A 124(7):517-526. 10.1007/s00339-018-1930-9
  • 23.Sharma D, Singh D, Pandey S, Yadav S, Kondekar PN. 2017. “Comparative analysis of full-gate and short-gate dielectric modulated electrically doped Tunnel-FET based biosensors. [DOI]
  • 24.Raad BR, Tirkey S, Sharma D, Kondekar P. A new design approach of dopingless tunnel FET for enhancement of device characteristics. IEEE Trans Electron Devices. 2017;64(4):1830–1836. doi: 10.1109/TED.2017.2672640. [DOI] [Google Scholar]
  • 25.Chandan BV, Nigam K, Rajan C, Sharma D. A fair comparison of the performance of charge plasma and electrostatic tunnel FETs for low-power high-frequency applications. J Comput Electron. 2019;18(4):1201–1206. doi: 10.1007/s10825-019-01388-2. [DOI] [Google Scholar]
  • 26.Boucart K, Ionescu AM. Double-gate tunnel FET with high- gate dielectric. IEEE Trans Electron Devices. 2007;54(7):1725–1733. doi: 10.1109/TED.2007.899389. [DOI] [Google Scholar]
  • 27.latikhameneh H, Ameen TA, Klimeck G, Appenzeller J, Rahman R. Dielectric engineered tunnel field-effect transistor. IEEE Electron Device Lett. 2015;36(10):1097–1100. doi: 10.1109/LED.2015.2474147. [DOI] [Google Scholar]
  • 28.Bandi V, et al. Junctionless based dielectric modulated electrically doped tunnel FET based biosensor for label-free detection. Micro Nano Lett. 2017;13(4):452–456. [Google Scholar]
  • 29.Wadhwa G, Raj B (2018) Label free detection of biomolecules using charge-plasma-based gate underlap dielectric modulated junctionless TFET,” J Electron Mater 47(8):4683-4693
  • 30.Rupam G et al (2019) Comparative analysis of circular gate TFET and Heterojunction TFET for dielectric-modulated label-free biosensing. IEEE Sens J 19(21):9600-9609
  • 31.Noor SL, Khan MZ (2017) Application of nanocavity embedded dual metal double gate TFET in biomolecule detection,” In Humanitarian Technology Conference (R10-HTC) IEEE Region, pp 345–348
  • 32.Shafi N, Sahu C, Periasamy C, Singh J (2017) SiGe source charge plasma TFET for biosensing applications,” In Nanoelectronic and Information Systems (iNIS). 2017 IEEE International Symposium, pp 93–98

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Citations

  1. Sharma D, Singh D, Pandey S, Yadav S, Kondekar PN. 2017. “Comparative analysis of full-gate and short-gate dielectric modulated electrically doped Tunnel-FET based biosensors. [DOI]

Data Availability Statement

Not applicable.

Not Applicable.


Articles from Silicon are provided here courtesy of Nature Publishing Group

RESOURCES