Abstract
Parahisian pacing (PHP) is a useful maneuver during electrophysiology study of supraventricular tachycardia (SVT) especially when the tachycardia is non-sustained. Various responses during PHP can differentiate between the routes of VA conduction (VAC). In a case of WPW syndrome with orthodromic re-entrant tachycardia, we encountered various responses which one must be cognizant about to avoid erroneous conclusions. Along with para-hisian capture and only ventricular capture, simultaneous atrial capture (SAC) and pure His capture were also noted. Moreover, during pure-His capture underlying distal antegrade right bundle branch block (RBBB) was encountered making it an intriguing case.
Keywords: Parahis pacing maneuver, Parahisian pacing, Simultaneous atrial capture
1. Case
A 40-year-old gentleman underwent electrophysiology study for WPW syndrome with recurrent orthodromic atrioventricular re-entrant tachycardia. A right anterior accessory pathway (AP) was ablated close to the septum anterior to His catheter (Appendix 1AB). During the study, parahisian pacing (PHP) was performed before and after ablation to determine the route of VA conduction (VAC). It is important to mention that the CS decapolar catheter could not be placed fully deep inside, hence CS-12 was located near middle CS whereas the CS-34 was 2–3 cm inside proximal CS. Another decapolar catheter was placed on the atrial aspect of tricuspid annulus, with RA-5 bipole near high right atrium (HRA) (Appendix 1AB). PHP was performed at 600 ms cycle length (PCL) starting at 20 mA current @ 2 ms pulse width. Keeping the PCL and catheter position fixed, the current output was gradually reduced in a stepwise manner when various responses were noted. What are the responses observed in Fig. 2 and Fig. 3?
Fig. 2.
Electrodes shown from top to bottom are four surface ECGs (1, aVF, V4, V1), CS12 (Middle CS) to CS34 (proximal), His distal and proximal, roving mapping catheter (MAP) right atrium RA 5 (proximal, near high RA) to RA 1 (distal, lower RA). A: First beat is A + H + V capture. Second beat is A + H capture. Adjacent atrial electrogram (marked as ‘A’) was noticeable along with the delayed separate ventricular EGM in the second beat (best seen in MAPp, marked as V). B: First beat is H + V with shorter SA. Second beat is H with a longer SA. However, the VA remains the same (red line). Longer SA (i.e HA here) during H with fixed VA suggest extra-nodal response via an accessory pathway. In addition, the atrial electrogram adjacent to pacing spike (A) is distinctly absent in Fig. 2B, as compared to the second beat of Figs. 1B and Fig. 2A. Underlying RBBB also got unmasked.
Fig. 3.
Electrodes shown from top to bottom are four surface ECGs (1, aVF, V4, V1), CS12 (Middle CS) to CS34 (proximal), His distal and proximal, roving mapping catheter (MAP) right atrium RA-5 (proximal, near high RA) to RA-1 (distal bipole, lower RA). A: Post-RFA para-his pacing: The wider first beat with myocardial capture had longer SA than narrower second beat (parahis capture, H + V) with identical atrial activation sequence. Hence, this VA conduction is via AV node. B: The catheter position and electrogram just before the maneuver shows a large A-EGM almost equal to V-EGM.
2. Commentary
In the subsequent discussion- His plus myocardium, only myocardial capture, pure His capture and simultaneous atrial captures are annotated as H + V, V, H, A + V respectively [1]. The ideal way to differentiate H + V vs. V capture is by analyzing whether His-signal is obscured inside or released from the ventricular signal on the second His catheter [2,3]. However, in our case they were concluded on the basis of QRS morphology and width as His release was not well appreciated.
In Fig. 1A, the first beat represented a V only capture (QRS width 138 ms) and second beat was a H + V (i.e. Para-His capture, QRS width −114 ms) capture. The atrial activation sequence remained identical suggesting only one route for VAC. The Stimulus-A electrogram (SA) measurements were also identical. This would be called an extra-nodal response. This proves the presence of an AP, although participation of the AP in supraventricular tachycardia cannot be ascertained from PHP maneuver.
Fig. 1.
Electrodes shown from top to bottom are four surface ECGs (1, aVF, V4, V1), CS12 (Middle CS) to CS34 (proximal), His distal and proximal, roving mapping catheter (MAP) right atrium RA 5 (proximal, near high RA) to RA 1 (distal). Measurements in msec. A: First beat is wider V capture beat and second beat is narrower H + V beat. The atrial activation sequence and SA measurements are similar in both beats suggestive of extra-nodal VAC. B: Both beats have V capture but the first beat also shows SAC (A + V) which got released in the next beat having true VAC.
Fig. 1B shows (at a different time during the same pacing protocol as Fig. 1A) V capture in both beats (QRS – 138 ms). A very short SA (40 ms in CS-12, 50 ms in HRA) was recorded in the first beat. The differentials of such a short SA are – (i) simultaneous or direct atrial capture (SAC) (A + V), (ii) Capture of ventricular end of AP. To validate SAC: if the pacing catheter is advanced slightly towards the ventricle and the VA interval becomes substantially longer, then it indicates that the very short VA interval was most likely due to SAC [3]. Another way to validate SAC is by looking for atrial electrograms immediately adjacent to the pacing spike at the catheter near the pacing bipole (MAPp and HisP here), although sometimes it is difficult to discriminate from V-EGM recorded nearly at the same time [4]. However, if anytime pure his capture (H) without any local myocardial capture can be achieved with (H + A) and without SAC (H) (also encountered in this case, described below), the difference of EGM attached to pacing spike could be compared to delineate presence or absence of atrial electrogram, respectively [4]. An easier and practical way to validate SAC, is to look for SA prolongation when the QRS morphology remains unchanged, as happened in the second beat (V) (Fig. 1B). Among the common responses during PHP, nodal response can also have prolongation of VA, but only during concomitant QRS widening and/or His-EGM release (if visible). In our case, nodal response was ruled out as the SA interval widened in spite of identical QRS width in the second beat. Hence, everything was suggestive of A + V in the first beat. Moreover, a short SA of <60 or 70 ms on the proximal CS or high right atrial electrodes respectively, is highly suggestive of SAC by itself as shown in an earlier study [5]. ‘Intermittent’ direct AP capture, an extremely rare finding, however cannot be ruled out from above observations.
Subsequently, Fig. 2A shows 2 similar but non-identical QRS. The QRS width is slightly narrower in the second beat. Both QRS are having an isoelectric interval. However, a close look at V4 shows slurring suggesting a probable H + V capture. The isoelectric interval is longer in the second beat, likely pointing towards H capture. The convincing proof was evident from intracardiac electrograms having late V-EGM recorded separately from the pacing artefact in the second beat (best appreciated in MAPd). Additional finding noted was SAC in both the beats (A + H + V and A + H). Unless this is promptly recognized there could be a mistaken consideration of the wider beat as V and narrower beat as H + V. In certain situations such errors can lead to a misdiagnosis [3]. Moreover, as the ventricular EGM of the second beat is delayed and recorded separately from the pacing spike, it rendered an opportunity to properly analyze the adjacent atrial electrogram (marked with ‘A’) in MAPp further confirming A + H.
The next intriguing observation noted in Fig. 2B during the PHP was prolongation of SA during H (second beat) as compared to H + V (first beat). This resulted in 38–45 ms increment in SA (i.e = HA here). In contrast, the VA interval was fixed (76 ms) during both the beats with similar atrial activation pattern. Fixed VA and variable HA again suggested an accessory pathway just from these 2 beats. An additional interesting observation was made when the underlying RBBB got unmasked during H (Fig. 2B). We believe, the prolongation of SA by 38–45 ms in second beat was exaggerated due to the underlying RBBB as during H the impulse has to travel down via left bundle (LB) followed by trans-septal conduction and then VAC via right sided AP. Interestingly, even during this pure H capture (second beat of Fig. 3B) the VAC did not show nodal response, but rather took a longer but still relatively faster route via the AP (Route A in Appendix 2). VAC over AV node (Route B in Appendix 2) might have taken place concomitantly, but was too slow to get reflected in the electrograms. This speculation is supported by post-ablation long VA time during nodal response (Fig. 3A).
To summarize, this single case illustrates several pitfalls and challenges encountered during PHP manoeuvre. We speculate, many of these happened because the pacing bipole (His-D) was more proximate to the atrial side of the proximal His region (Fig. 3B). We believe, unwarranted findings like SAC might be avoided by placing the pacing catheter at a more preferable distal His region [2,3]. Pure H capture, a rare finding, can confound the interpretations if not recognized by subtle differences from H + V capture. Having a dedicated RV apex and RV base catheter can help identify H with the EGMs in the former preceding the latter. When identified correctly, H capture can offer important electrophysiological insights in deciphering the route of VAC.
Funding
None.
Data availability statement
All raw data and recording during the case are available for review.
Declaration of competing interest
None.
Consent has been taken from the patient.
Acknowledgement
We sincerely thank Dr. Amit Vora and eminent IHRS members for their valuable inputs. We also wish to extend our regards to Dr. Ayan Kar for helping us to develop the schematic diagram.
Footnotes
Peer review under responsibility of Indian Heart Rhythm Society.
Supplementary data to this article can be found online at https://doi.org/10.1016/j.ipej.2021.08.001.
Appendix A. Supplementary data
The following are the Supplementary data to this article:
1A: Fluoroscopy image of successful site in right anterior oblique 30-degree projection.
1B: Fluoroscopy image of successful ablation site in left anterior oblique 35-degree projection. Also notice the CS and RA catheter position.
Schematic diagram showing faster VA conduction through longer route: left bundle trans-septal conduction AP (Route A), than slower VA conduction via AV node (Route B) during pure H capture.
References
- 1.Obeyesekere M.N., Leong-Sit P., Gula L.J., Klein G.J. Seven manifestations of para-hisian pacing. J Cardiovasc Electrophysiol. 2012;23(9):1035–1036. doi: 10.1111/j.1540-8167.2011.02242.x. Epub 2011 Dec 15, PMID: 22172055. [DOI] [PubMed] [Google Scholar]
- 2.Hirao K., Otomo K., Wang X. Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node. Circulation. 1996;94:1027–1035. doi: 10.1161/01.cir.94.5.1027. [DOI] [PubMed] [Google Scholar]
- 3.Sheldon S.H., Li H.-K., Asirvatham S.J., McLeod C.J. Parahisian pacing: technique, utility, and pitfalls. J Intervent Card Electrophysiol. 2014 Aug;40(2):105–116. doi: 10.1007/s10840-014-9908-9. [DOI] [PubMed] [Google Scholar]
- 4.Sunny S. Self-published digital book; 2019. Po. Warren Jackman's art of war: a snipers approach to catheter ablation; p. 11. Chapter1. [Google Scholar]
- 5.Obeyesekere M., Leong-Sit P., Skanes A. Determination of inadvertent atrial capture during para-Hisian pacing. Circulation. Arrhythmia and Electrophysiology. 2011;4:510–514. doi: 10.1161/CIRCEP.111.963058. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
1A: Fluoroscopy image of successful site in right anterior oblique 30-degree projection.
1B: Fluoroscopy image of successful ablation site in left anterior oblique 35-degree projection. Also notice the CS and RA catheter position.
Schematic diagram showing faster VA conduction through longer route: left bundle trans-septal conduction AP (Route A), than slower VA conduction via AV node (Route B) during pure H capture.
Data Availability Statement
All raw data and recording during the case are available for review.