Abstract
Background:
Iodine material images (aka iodine basis images) generated from dual energy computed tomography (DECT) have been used to assess potential perfusion defects in the pulmonary parenchyma. However, iodine material images do not provide the needed absolute quantification of the pulmonary blood pool, as materials with effective atomic numbers (Zeff) different from those of basis materials may also contribute to iodine material images, thus confounding the quantification of perfusion defects.
Purpose:
(i) To demonstrate the limitations of iodine material images in pulmonary perfusion defect quantification and (ii) to develop and validate a new quantitative biomarker using effective atomic numbers derived from DECT images.
Methods:
The quantitative relationship between the perfusion blood volume (PBV) in pulmonary parenchyma and the effective atomic number (Zeff) spatial distribution was studied to show that the desired quantitative PBV maps are determined by the spatial maps of Zeff as , where a, b, and β are three constants. Namely, quantitative is determined by Zeff images instead of the iodine basis images. Perfusion maps were generated for four human subjects to demonstrate the differences between conventional iodine material image-based PBV (PBViodine) derived from two-material decompositions and the proposed method.
Results:
Among patients with pulmonary emboli, the proposed maps clearly show the perfusion defects while the PBViodine maps do not. Additionally, when there are no perfusion defects present in the derived PBV maps, no pulmonary emboli were diagnosed by an experienced thoracic radiologist.
Conclusion:
Effective atomic number–based quantitative PBV maps provide the needed sensitive and specific biomarker to quantify pulmonary perfusion defects.
Keywords: dual energy CT, effective atomic number map, functional lung imaging, material decomposition, multienergy CT, pulmonary embolism, pulmonary perfusion imaging, quantitative imaging
1 |. INTRODUCTION
Venous thromboembolism is a major global health concern and an economic burden with approximately 10 million cases occurring each year and a high lifetime risk of 8% after 45 years of age.5 Pulmonary embolism (PE) is a venous thromboembolic event associated with high morbidity and mortality.5 Currently, pulmonary CT angiography (CTA) is the preferred imaging modality for evaluating patients with clinically suspected acute PE.6–17 Pulmonary CTA can also be used for the evaluation of other pulmonary thromboembolic diseases, such as chronic PE and chronic thromboembolic pulmonary hypertension (CTEPH).Pulmonary emboli often manifest as partial or complete intraluminal pulmonary vessel filling defects on pulmonary CTA images and each defect usually presents a sharp interface with the iodinated contrast. However, these radiological features are not specific to pulmonary emboli and can also result from a number of other pathological factors (e.g., the presence of a mucus plug or perivascular edema) and anatomical factors (e.g., vascular bifurcations and misidentification of pulmonary veins), all of which can generate PE-mimicking filling defects on pulmonary CTA images.8 In addition, the success rate and diagnostic accuracy of anatomic imaging with pulmonary CTA drop as the vessel size decreases to the subsegmental level.17 Furthermore, pulmonary CTA only provides anatomic imaging of pulmonary vessels and does not provide a direct assessment of the impact of PE on lung parenchymal perfusion. Also pulmonary CTA neither directly provide prognostic biomarkers of hemodynamic compromise nor identify patients at risk for fatal or other adverse events. The incapability to demonstrate parenchymal perfusion abnormalities remains an important limitation of CTA-based evaluation of pulmonary thromboembolic diseases.
As an alternative to pulmonary CTA, lung ventilation/perfusion (V/Q) scintigraphy and single photon emission computed tomography (SPECT) are used to evaluate pulmonary thromboembolic diseases. For patients with suspected CTEPH or chronic PE, the selection between CTA and nuclear medicine imaging often creates a diagnostic dilemma: CTA provides direct imaging of the embolus itself without parenchymal perfusion information, while nuclear medicine imaging provides functional information without direct proof of emboli. To extricate physicians from this dilemma, patients with suspected CTEPH may need to receive both CTA and nuclear medicine lung imaging, which increases both the overall healthcare cost and the ionizing radiation dose to patients. As a result, there is a compelling unmet clinical need to develop a method for simultaneous pulmonary vessel morphological assessment and parenchymal perfusion assessment without applying separate CT and nuclear medicine scans to the same patient.
Towards providing a “one-stop-shop” solution to morphological and functional lung imaging, prior studies have investigated the use of dynamic CT imaging to extract pulmonary perfusion information. However, this approach has not been clinically accepted resulting from concerns regarding radiation dose:18–20 the effective dose of dynamic chest CT is approximately 7 mSv, compared to 2 mSv for a typical static pulmonary CTA scan.21 Another strategy employed is to use static dual energy CT (DECT) or multienergy CT (MECT) which do not require a prolonged breath-hold or a significant increase in radiation dose.22–29 A DECT scan generates the so-called iodine material images (from iodine–water or iodine–soft tissue–air material decompositions) that can be used as a corollary for pulmonary perfusion blood volume (PBV) maps to depict the location and pattern of pulmonary perfusion defects. For a given pulmonary embolus identified on CTA images, the addition of those iodine material image-based PBV (PBViodine) maps can assist physicians in estimating the probability and severity of tissue damage while providing a prognosis and risk stratification in patients presenting with pulmonary thromboembolic diseases, including typical presentations and those associated with alternate diagnoses, such as COVID-19 pneumonia.7,30–35
However, as shown by a recent survey conducted by the Society of Thoracic Radiology,36 iodine material image-based pulmonary perfusion imaging remains underutilized in clinical practice due to several important limitations. The first important limitation of the iodine material image is that its signal does not necessarily reflect the magnitude of the pulmonary blood pool, as noniodine materials with Zeff different from that of the counterpart basis material (e.g., water) can also contribute to the iodine image signal. This is particularly a problem for pulmonary consolidation and ground-glass opacity (GGO) that may not only have different Zeff (relative to water), but also much higher densities than the normal lung tissue: as shown by the analysis in Section 2.2 and published literature,37–39 those tissues can generate a relatively high signal in PBViodine images which can mislead the evaluation of regional perfusion conditions. The second limitation lies in the fact that DECT-based iodine material images can only provide a relative measurement of PBV. In fact, physicians heavily rely on comparing the iodine intensity across different lung lobes to identify regional perfusion defects. Due to this relative assessment nature, literature on DECT pulmonary perfusion imaging rarely reports the physical units of the pulmonary perfusion maps. This limitation poses a challenge in diagnosing systematic pulmonary defects.
The purpose of this work is to develop a new framework to derive quantitative pulmonary PBV maps from the available DECT data to overcome the current limitations of iodine image-based perfusion assessment and also achieve simultaneous functional and anatomical lung imaging using DECT acquisitions. The method was developed based on the physiological meaning of PBV and the imaging physics of DECT. The main contribution of this work is to show that the quantitative and absolute PBV measurements are determined by the local effective atomic number (Zeff) distribution and can become an intrinsic absolute quantification of the perfused blood pool.
2 |. MATERIALS AND METHODS
2.1 |. Pulmonary PBV from DECT imaging
By definition, as shown in the model presented in Figure 1, PBV is the blood volume perfused into a unit mass of lung tissue in a volume-of-interest (VOI) located at x:
| (1) |
where Vcap(x) denotes the volume of the capillary bed within the VOI and mlung(x) denotes the mass of the lung tissue in the VOI (Figure 1).
FIGURE 1.
An illustration of the concept of pulmonary perfusion blood volume (PBV). For a given volume-of-interest (VOI) in the lung parenchyma, its PBV is given by the ratio between the volume occupied by the capillaries (Vcap) and the mass of the lung tissue in the VOI (mlung). mlung = Vlungρlung, where Vlung and ρlung are the VOI volume and the lung tissue density, respectively. By definition, PBV is independent of the injected iodine concentration
In practice, it is difficult to directly measure the volume of the capillary bed within a VOI due to the limited spatial resolution of CT relative to the capillary size. Therefore, PBV must be determined from other quantities measurable in CT images. Using the mass conservation principle, as shown by the derivations presented in Appendix I, Equation (1) can be recast into the following form:
| (2) |
where ρlung(x) denotes the mass density of the lung tissue in the VOI at x, is the concentration of the injected iodine at the feeding pulmonary artery, and ρI(x) is the iodine concentration in the VOI. The key difference between Equations (1) and (2) is that the three quantities in Equation (2) are, in principle, measurable using DECT imaging technology. For example, ρI(x) and can be measured based on the signal values of the iodine material image, and ρlung(x) can be measured using the water material image. These measurements do not require the CT to have capillary-level spatial resolution. In reality, however, the signals of the iodine and water material images do not always provide quantitatively accurate iodine concentrations and lung tissue densities. To explain this reason, let’s review the so-called “material decomposition”, in which the linear attenuation coefficient of the VOI at x is decomposed into two material bases as
| (3) |
or three material bases as
| (4) |
Here, E denotes the X-ray energy, and (μ/ρ)I, (μ/ρ)w, and (μ/ρ)air denote the mass attenuation coefficients of pure iodine, water, and air, respectively. The material “water” can also be replaced by a “standard soft tissue material” defined by the CT vendor or the end-user, but the overall working principle remains the same.
2.2 |. Conventional “relative PBV” measurements using iodine basis images
The iodine material image, aI(x), which describes the concentration of “iodine-like” materials, was used in literature24,33,34 as a surrogate for the PBV since it is assumed to be equivalent to ρI(x), the true iodine concentration in the VOI, namely
| (5) |
where κ is a numerical constant. In other words, the iodine material image is assumed to be linearly proportional to the PBV, and ρlung(x) in Equation (2) is assumed to be constant throughout the lungs. However, these assumptions are not well supported by imaging physics as discussed below.
First, the iodine material image, aI(x), does not necessarily provide the accurate iodine concentration distribution, ρI(x), despite the fact that the physical units of aI(x) and ρI(x) are the same (i.e., mg/ml). The actual physical meaning of aI(x) and aw(x) from water–iodine material decompositions are given by the following formulae40,41:
| (6) |
| (7) |
where β is an energy- and material-independent numerical constant, Na is the Avogadro constant, ρe denotes electron density, A denotes the atomic mass number, and Z denotes the atomic number. For example, ZI (=53) and Zw (=7.4) are the atomic numbers of pure iodine and water, respectively. As shown in Appendix II, aI(x) is equal to ρI(x) only under the condition that the VOI is entirely composed of the basis materials. When a voxel contains a foreign material with a Zeff different from those of the basis materials, its contribution to the X-ray attenuation will be assigned to both material basis images. In that case, the assumption that aI(x) is same as ρI(x) inevitably leads to either over- or under-estimation of the PBV.
Second, compared with the PBV formula in Equation (2), using aI as a surrogate for the PBV ignores the dependence of the PBV on the lung tissue density ρlung(x), a quantity that varies spatially in the lung. Therefore, the lack of consideration of the spatially varying ρlung(x) in PBViodine is problematic.
To experimentally demonstrate the possible contribution of consolidation to the iodine material image signal, the Zeff of pulmonary consolidation was experimentally measured using the DECT images (Gemstone Spectral Imaging (GSI), GE Healthcare) of a human subject. Information about the patient and the scan protocol is provided in Table 2 (Subject 1). Ideally, the measurement of the Zeff of pulmonary consolidation should use non-contrast DECT data to avoid the impact of iodine to the Zeff result. Since no non-contrast chest DECT exam is performed at the authors’ institutions, we had to use contrast-enhanced chest DECT: we carefully chose a subject that had both pulmonary consolidation and known acute PE and impaired blood perfusion to the consolidated regions to minimize the influence of the iodine. Measurement of consolidation Zeff was performed in a carefully chosen VOI without perceivable contrast-enhanced vessels as corroborated by the pulmonary CTA images. As shown in Figure 2 and Table 1, Zeff of the consolidated tissue (8.11 [7.91, 8.29]) is indeed higher than that of water (7.42). Therefore, even without any iodine uptake, the consolidation can contribute to the signal of iodine material images. Further, the electron density (ρe) of the consolidated tissue measured by DECT is approximately three times that of the normal lung tissue’s ρe. According to Equation (6), a larger ρe further increases the signal of consolidated tissue in the iodine material image.
TABLE 2.
Subject demographics and scan parameters
| Subject 1 | Subject 2 | Subject 3 | Subject 4 | |
|---|---|---|---|---|
|
| ||||
| Age | 40 | 65 | 68 | 23 |
| BMI | 26.9 | 36.9 | 27.4 | 20.4 |
| Gender | Male | Female | Male | Female |
| Scanner | 750HD | Revolution | Revolution | Revolution |
| Contrast volume (ml) | 100 | 100 | 100 | 100 |
| Contrast type | Isovue370 | Omnipaque300 | Omnipaque300 | Omnipaque300 |
| Helical pitch | 1.375 | 0.992 | 0.992 | 0.992 |
| Beam collimation (mm) | 40 | 80 | 80 | 80 |
| Rotation time | 0.5 | 0.5 | 0.5 | 0.5 |
| mA | 600 | 240 | 200 | 200 |
| Slice thickness (mm) | 2.5 | 1.25 | 1.25 | 1.25 |
FIGURE 2.
Experimental measurement of Zeff and ρe using dual energy CT (DECT) data of an acute pulmonary embolism (PE) patient with extensive bilateral consolidations and clinically proven pulmonary perfusion deficits. The dotted circles indicate volume-of-interests (VOIs) where measurements were performed. These VOIs are located within the consolidations without perceivable iodine uptake as shown by the CT angiography (CTA) maximum intensity projection (MIP) image. The results confirmed that Zeff of the consolidation (8.11 [7.91, 8.29]) is higher than that of water (7.42) and its ρe (0.55 [0.54, 0.56] mol/ml) is more than three times that of the ρe of the normally aerated lung tissue (0.16 [0.10, 0.23] mol/ml)
TABLE 1.
Values of effective atomic number (Zeff), mass density (ρ), and electron density (ρe) of typical materials in the chest
| Material | Air (dry) | Normal lung tissue | Adipose tissue | Water | Muscle | Iodine | Pulmonary consolidation |
|---|---|---|---|---|---|---|---|
|
| |||||||
| Z eff | 7.66 | 7.44 [7.34, 7.46] | 5.82 [5.69, 5.90] | 7.42 | 7.52 [7.42, 7.52] | 53 | 8.11 [7.91, 8.29] |
| ρ (g/ml) | 1.2 × 10−3 | 0.29 [0.17, 0.41] | 0.95 | 1.0 | 1.05 | 4.9 | 0.98 [0.96, 1.00] |
| ρe (mol/ml) | 6.0 × 10−4 | 0.16 [0.10, 0.23] | 0.53 | 0.56 | 0.58 | 2.05 | 0.55 [0.54, 0.56] |
Note: Except for pulmonary consolidation, the values are taken from the NIST Standard Reference Database No. 126 and other published papers.1–4 The values for the pulmonary consolidation were experimentally measured from the human subject image data shown in Figure 2.
As another demonstration, Figure 3 plots low-kV μ values against high-kV μ values for consolidated and normal lung tissues of a human subject. A line connecting the consolidation and normal lung tissue data points has a slope of 1.19 (99% CI [1.17, 1.21]), which is larger than the slope of water (1.14). Because the slope is positively correlated to the effective atomic number,42 this figure implies that compared with normal lung tissues, consolidations contain additional materials with Zeff larger than that of water. All these experimental data support the premise that consolidated lung tissue contributes to the iodine material image and thus PBViodine is not a robust and accurate metric of pulmonary perfusion, as a higher PBViodine value does not necessarily mean a higher blood volume, and a “normal” PBViodine value does not necessarily rule out perfusion defects.
FIGURE 3.
(a) 140 kV contrast-enhanced CT image of a patient showing consolidation in the right lung. Two region-of-interests (ROIs) were drawn on the consolidation and the contralateral normal lung tissue. (b) For each ROI, its mean attenuation coefficient measured in the 80 kV image (μlow) was plotted against the attenuation coefficient measured in the 140 kV image (μhigh). In part (b), the “+” markers indicate individual data points in each ROI while each solid disk marker represents the ROI mean. The black line connecting the data of ROI 1 and ROI 2 has a slope of 1.19 (99% CI [1.17, 1.21]), which is larger than the slope of water (1.14). This implies that compared with the normal lung tissue, the consolidation contains materials with Zeff slightly higher than that of water
2.3 |. Absolute quantification of pulmonary PBV from DECT-based Zeff imaging
Instead of using the iodine material image-based PBViodine, a new metric was developed in this work to quantitatively measure PBV.As shown in Appendix II, the PBV defined in Equation (2) is quantitatively related to the effective atomic number Zeff as follows:
| (8) |
where constants k and b are determined as follows:
| (9) |
A value of 2.94 is widely used in literature for the exponent β.43,44 For the term (iodine concentration in a feeding pulmonary artery), it can be reliability measured from the iodine material image due to the absence of consolidations within the large artery. Equation (8) provides an absolute (rather than relative) measurement of PBV with a physical unit of (ml/g) or (ml/100 g) depending on the user’s preference.
2.4 |. Proof-of-concept human subject evaluation studies
As an initial proof-of-concept evaluation of the proposed quantitative measurement method, pulmonary DECT angiography data of four human subjects were retrospectively collected and processed under IRB approval. Among these subjects, three received DECT on a 256-slice MDCT scanner (Revolution CT,GE Healthcare) equipped with the GSI DECT technology; one subject received DECT on a 64-slice MDCT scanner (Discovery CT750 HD, GE Healthcare) equipped with GSI. The age, gender, BMI, and other relevant information about the DECT exams are listed in Table 2.
2.4.1 |. DECT scan protocol
For scans performed on the 256-slice CT system, the intravenous contrast injection used 100 ml of Iohexol 300 mg I/ml (Omnipaque 300; GE Healthcare) with a 10 ml saline flush, both at a rate of 5 ml/s. A bolus tracking scan (SmartPrep, GE Healthcare) was used to determine the scan timing: once the enhancement in the left atrium exceeded 60 HU, the actual DECT angiography scan was triggered and performed under the helical mode with a helical pitch of 0.992. The scan range extended from the apices of the lung to just below the diaphragm. The X-ray tube potential rapidly switched between 80 and 140 kV while the gantry rotated at a speed of 0.5 s per revolution. The tube current (mA) was adjusted for each subject based on their body size under the guidance of the GSI-assist technology. The beam collimation was 80 mm and the reconstruction slice thickness was 1.25 mm. For the subject who received the DECT on the 64-slice scanner, the beam collimation was 40 mm and the reconstruction slice thickness was 2.5 mm. The contrast injection was 100 ml of Iopamidol 370 mg I/ml (Isovue 370; Bracco Diagnostics Inc.) at a rate of 4 ml/s, followed by 45 ml of saline at 2 ml/s. The bolus tracking scan used a region-of-interest (ROI) placed on the pulmonary artery at the level of carina, and the trigger threshold was 110 HU. Other scan parameters are listed in Table 2.
2.4.2 |. Image processing and data analysis
For the DECT acquisition of each subject, iodine (water) and water (iodine) material images were directly generated by the CT scanner. According to the CT manufacturer, these material images were generated via a two-material (water–iodine) decomposition process without requiring any knowledge of each material’s volume fraction or the volume-conservation assumption. GE DECT systems also provide Zeff maps. If Zeff is not directly available, it can be computed from the water and iodine material images as follows:
where Zw = 7.42, ZI = 53, (z/A)w = 0.555, (z/A)I = 0.418, and β = 2.94.
The iodine concentration of the feeding artery, , was measured by placing an ROI on the pulmonary trunk in the iodine material image. Since the ROI is completely within the iodinated blood, its aI signal can be safely used to estimate the input iodine concentration, . Next, Equation (8) and the measured Zeff and were used to calculate of each pixel within the lungs. The measured was applied to the whole lung regions of a given patient. The calculation of was performed off the CT console on a computer using the Matlab software (version R2020b; Mathworks, Inc.) and the results were saved as RGB DICOM images for radiologist review. For comparison purposes, conventional PBViodine maps were also generated from iodine material images. The lung region of each PBV map was color-coded using the “hot” color map and overlaid on the corresponding grayscale 140 kV equivalent CT image.
A radiologist with 35 years of clinical experience evaluated both and PBViodine maps. For each patient and each type of PBV map, the reader evaluated whether the images demonstrated evidence of perfusion defects, GGOs, consolidations, atelectasis, lung tumors, or other pulmonary abnormalities; the gold-standard diagnosis was established based on clinical and laboratory records, CT and nuclear medicine images (if available), and other relevant imaging results. The diagnostic performance of and PBViodine were compared qualitatively by the experienced radiologist.
3 |. RESULTS
Figures 4–7 show color-coded and PBViodine maps of the patients’ lung regions overlaid on top of the corresponding grayscale CT images. Quantitative measurement results of PBV, material image signals, Zeff, and electron density (ρe) values are summarized in Table 3. In addition, the Supporting Information provides the original water and iodine material images, Zeff maps, and ρe maps without using the color overlay display method.
FIGURE 4.
Images of Subject 1 with clinically proven pneumonia and acute pulmonary embolism. The CT angiography source images in Row 1 show multiple segmental and subsegmental pulmonary emboli (pointed by the arrows) in the vessels that supply the posterior regions of the left and right lungs. The CT images in Row 2 with a wider display range show extensive ground-glass opacity and consolidation in both lungs. maps (color overlay on the grayscale CT image) in Row 3 demonstrated regional perfusion defects in the posterior area of both lungs. In contrast, PBViodine maps (color overlay on the grayscale CT image) in Row 4 do not clearly show the perfusion abnormalities because the consolidated tissue contributed to the iodine material image signal such that the reduction of iodine concentration in the consolidated area was counteracted in PBViodine
FIGURE 7.
Images of a “control case” (Subject 4) without pulmonary embolism and without pulmonary hypertension. The lung regions of PBViodine and maps are color-coded and overlaid on the grayscale CT images
TABLE 3.
Results of quantitative measurements (mean value [first quantile, third quantile]) of the four subjects’ DECT image data
| Subject 1 | |||||
|
| |||||
| Normally aerated | Consolidation | p | |||
|
| |||||
| HU | −769 | [−856, −760] | 37 | [15, 69] | <0.001 |
| aI (mg/ml) | 1.2 | [0.2, 1.5] | 1.2 | [1.0, 1.6] | 0.626 |
| aw (g/ml) | 0.183 | [0.122, 0.202] | 1.015 | [0.998, 1.035] | <0.001 |
| ρe (mol/ml) | 0.108 | [0.072, 0.114] | 0.552 | [0.544, 0.561] | <0.001 |
| Z eff | 9.25 | [8.63, 9.85] | 8.11 | [7.91, 8.29] | <0.001 |
| PBVZeff (mg/100 g) | 29.29 | [17.10, 40.22] | 9.42 | [6.37, 11.98] | 0.001 |
|
| |||||
| Subject 2 | |||||
|
| |||||
| Normally aerated | Ground-glass opacity | p | |||
|
| |||||
| HU | −885 | [−926, −8.76] | −610 | [−640, −568] | <0.001 |
| aI (mg/ml) | 0.9 | [0.4, 1.1] | 1.6 | [1.1, 2.2] | <0.001 |
| aw (g/ml) | 0.091 | [0.065, 0.091] | 0.349 | [0.334, 0.377] | <0.001 |
| ρe (mol/ml) | 0.050 | [0.036, 0.051] | 0.194 | [0.186, 0.210] | <0.001 |
| Z eff | 10.46 | [9.93, 11.11] | 8.83 | [8.79, 9.74] | <0.001 |
| PBVZeff (mg/100 g) | 32.70 | [24.37, 41.46] | 8.78 | [7.66, 14.56] | <0.001 |
|
| |||||
| Subject 3 | |||||
|
| |||||
| Right lung | Left lung with atelectasis | P | |||
|
| |||||
| HU | −517 | [−652, −428] | 197 | [164, 227] | <0.001 |
| aI (mg/ml) | 3.0 | [1.8, 4.2] | 6.7 | [5.8, 7.6] | <0.001 |
| aw (g/ml) | 0.405 | [0.302, 0.457] | 1.022 | [1.013, 1.030] | <0.001 |
| ρe (mol/ml) | 0.226 | [0.168, 0.256] | 0.570 | [0.565, 0.575] | <0.001 |
| Z eff | 10.09 | [9.71, 10.34] | 10.10 | [9.71, 10.34] | 0.096 |
| PBVZeff (mg/100 g) | 32.24 | [19.40, 45.73] | 32.82 | [26.66, 36.51] | 0.566 |
|
| |||||
| Subject 4 | |||||
|
| |||||
| Right lung | Left lung | P | |||
|
| |||||
| HU | −725 | [−778, −713] | −723 | [−767, −699] | 0.840 |
| aI (mg/ml) | 2.7 | [1.9, 3.0] | 2.6 | [1.8, 3.0] | 0.437 |
| aw (g/ml) | 0.206 | [0.174, 0.206] | 0.209 | [0.186, 0.218] | 0.407 |
| ρe (mol/ml) | 0.115 | [0.098, 0.116] | 0.117 | [0.104, 0.122] | 0.389 |
| Z eff | 11.21 | [10.09, 11.67] | 11.13 | [10.04, 11.86] | 0.220 |
| PBVZeff (mg/100 g) | 44.47 | [26.70, 51.02] | 43.13 | [26,00, 54.25] | 0.212 |
Note: The p values were given by two-sample t-tests with the unequal variance assumption.
Figure 4 shows images of Subject 1 with clinically confirmed acute PE and pneumonia. Extensive GGO and consolidation were found in the posterior regions of both the lungs. As shown by this subject’s pulmonary CTA source images in the first row of Figure 4, multiple emboli exist in the pulmonary vessels supplying the posterior lung regions. maps demonstrate regional perfusion defects in the lungs. In comparison, PBViodine maps do not clearly show the perfusion defects. This is because the consolidation and GGO contributed to the iodine material images and counteracted the reduction of iodine uptake in those areas.
Figure 5 shows images of Subject 2 with clinically confirmed PE. The subject has a history of lung infection and consolidations and GGOs within the bilateral upper and right middle lobes. The bilateral lobar, segmental and subsegmental pulmonary emboli can be seen on the pulmonary CTA images in the first row in Figure 5. The PBV maps show a global reduction in blood volume; some regions such as the bilateral upper lobes show severe perfusion defects. Although the PBViodine maps also show regional defects in the upper lobes, they failed to show the systematic reduction in blood perfusion because their values do not provide the quantitative blood volume level and are dependent on extrinsic factors such as the injected iodinated contrast level. The GGOs contributed to the iodine material image signal and reduced the sensitivity of PBViodine maps to perfusion defects.
FIGURE 5.
Images of Subject 2 with clinically confirmed pulmonary embolism. The CT angiography (CTA) source images in Row 1 show bilateral lobar, segmental, and subsegmental pulmonary emboli (arrows). The lung-window CT images in Row 2 show bilateral ground-glass opacities. The bilateral perfusion defects can be visualized more clearly in the maps (color overlay on the grayscale CT image) in Row 3 than the PBViodine maps (color overlay on the grayscale CT image) in Row 4
Figure 6 shows images of Subject 3 who has large left and medium right pleural effusions, loculations in the right oblique fissure, compressive collapse of the left lower lobe, and lung edema with atelectasis in the left lung. However, no PE or pulmonary hypertension was found in this patient. The maps show normal perfusion with an average PBV value of 33 [27, 37] ml/100 g in the left lung and 32 [19, 46] ml/100 g in the right lung. In comparison, the iodine material images of this subject show a much higher signal in the left lung (6.7 [5.8, 7.6] mg/ml) than the right lung (3.0 [1.8, 4.2] mg/ml, p < 0.001). Instead of a greater blood perfusion, the high iodine material image signal of the left lung was actually caused by the lung fluid that has a Zeff different from that of water. If a sub-optimal display range is used for the iodine basis image (fourth column in Figure 6), the right lung may appear hypoperfused compared with the left lung. This example shows a limitation of the iodine image-based relative perfusion measurement and an advantage of the proposed quantitative PBV measurement.
FIGURE 6.
Images of Subject 3 without any pulmonary embolism or pulmonary hypertension. The patient has large pleural effusions and compressive collapse in the left lung. The atelectasis in the left lung significantly elevated the local signal in the iodine material images. Consequently, when an adaptive display range is selected for PBViodine maps, the right lung appears to be hypoperfused compared with the left lung. In contrast, the maps are robust against local density variation and shows a uniform pulmonary perfusion. The lung regions of PBViodine and maps are color-coded and overlaid on the grayscale CT images
Finally, Figure 7 shows images of a “control” case (Subject 4) whose gold-standard clinical diagnosis has ruled out PE, CTEPH, or other lung diseases. For this subject without any consolidation and GGO, both and PBViodine maps show normal pulmonary perfusion signals without any false positives or false negatives. Meanwhile, blood vessels in PBViodine show higher PBViodine signals than the normally aerated lung parenchyma because of the higher electron density of the vessels (see the Supporting Information for the electron density maps). In clinical practice, the much brighter vessels can be distracting for the evaluation of parenchymal perfusions and they are segmented and hidden on PBViodine maps in some products.47,48 In comparison, the proposed map is more homogenous since the definition of PBV in Equation (2) requires a normalization of the local tissue density.
4 |. DISCUSSION
In the current DECT PBViodine method, pulmonary perfusion conditions are estimated using iodine material images generated by applying a two- or three-material decomposition to the acquired DECT data. There are two fundamental pitfalls of this approach. First, as shown in Equation (5), a material with an effective atomic number different from those of the basis materials can be partially assigned to the iodine basis images. Therefore, the iodine material images, aI(x), do not necessarily provide quantitatively accurate iodine density distribution, ρI(x). The difference between aI(x) and ρI(x) can be significant for consolidations and GGOs that have not only a higher Zeff relative to water but also a higher density relative to the normal lung tissue. Second, by definition, PBV is the volume of blood perfused per unit mass of lung tissue (Equation (1)). The iodine material images do not reflect the mass of the lung tissue. One can argue that the signal of aI(x) with a unit of (mg/ml) has a positive correlation with ρI(x) and thus has a positive correlation with PBV according to Equation (2). However, the existence of a positive correlation is not equivalent to quantitatively accurate PBV due to the fact that an important quantity, ρlung(x), in the PBV formula in Equation (2) is not characterized by aI(x).
Due to the two pitfalls of PBViodine, the identification of perfusion defects in PBViodine maps would have to rely heavily on the choice of display window/level, the choice of display color map, the relative difference in color between different lung regions, and the reader’s experience. In addition, as shown by the human subject results in this work, lung regions with consolidations and GGOs can generate a higher PBViodine signal relative to the normally aerated lung regions. In fact, data published in multiple prior studies support the existence of this effect.37–39 For example, in a fast kV switching DECT study of patients with COVID-19 pneumonia and suspected PE, two of the three showcases demonstrated higher iodine material image signal in the consolidation regions than the normally aerated parenchyma regions: one case shows aI value of 6.053 mg/ml in the consolidation, compared to 0.723 mg/ml in the normally aerated region.37 In another dual-source DECT-based study of patients with GGOs, two of the three showcases demonstrated higher aI signals in the GGO regions than normally aerated regions.38 The increased signal of consolidations and GGOs in PBViodine maps can be misleading, as both the reflex pulmonary artery vasoconstriction theory and nuclear medicine perfusion imaging can indicate a decreased (instead of increased) perfusion for consolidations and GGOs.45,46 Due to this limitation of PBViodine, some DECT postprocessing tools exclude consolidation or GGO regions in the final PBViodine maps, despite the strong clinical needs to assess perfusion conditions of these regions, particularly for patients with COVID-19 pneumonia.47,48
In contrast to PBViodine, this work shows that derived from DECT data is a quantitative biomarker of pulmonary perfused blood volume. As shown by the preliminary human subject results presented in Section 4, for patients with acute PE and pneumonia, the quantitative PBV maps clearly demonstrate regional perfusion defects in the area supplied by the embolized vessels, while the iodine material images failed to demonstrate the defects since pneumonia-induced consolidations add a positive signal to the iodine material image to counteract the reduced perfusion in the area. More interestingly, for a patient without PE, but with pleural effusion and atelectasis, the quantitative maps correctly demonstrate normal perfusion and are more specific than iodine image-based relative perfusion maps.
Although Equation (8) provides a formula to calculate from the βth power of Zeff, it is not the only approach to calculate : as shown by Equation (S18) in Appendix II, can also be obtained via a pixel-wise division of the iodine material image by the electron density image, albeit some commercial DECT systems do not directly provide electron density images. Fundamentally speaking, both of the two calculation methods are derived from the definition of PBV and are equivalent. In practice, one can choose either one based on the types of DECT images provided by a given clinical system.
This work has the following limitations. First, only four representative human subject cases were studied to demonstrate the pitfalls of the conventional PBViodine evaluation method and to show the effectiveness of the proposed quantitative metric based on the effective atomic number maps. To fully demonstrate the clinical value of , a large cohort of human subject studies needs to be studied in the future. Second, it is worth emphasizing that derived from DECT data only represents a steady-state perfusion measurement. It does not provide other important hemodynamic information such as pulmonary blood flow. If one desires to obtain a complete set of perfusion measurements including pulmonary flow information, time-resolved CT scans are required for measuring the contrast dynamics of pulmonary vasculature and tissues. Third, the iodine material images and PBViodine maps in this work were generated by commercial CT scanners from a single vendor that uses two-material (water and iodine) decomposition. It is possible that by using three- or multi-material decompositions (especially with one basis material similar to consolidations and GGOs in terms of Zeff), the issues of the iodine material image and PBViodine in quantifying the perfusion of consolidated and GGO regions can be mitigated. However, the selection of the proper basis material can be challenging, considering the Zeff of consolidations and GGOs may vary across patients. How to further improve DECT material decomposition for more accurate pulmonary embolism detection and how PBViodine from improved multi-material decomposition compares to deserve further investigation in the future.
5 |. CONCLUSION
In conclusion, a new quantitative biomarker, , from DECT imaging was developed to quantitatively assess pulmonary PBV. Compared with the relative pulmonary perfusion measurements using iodine images derived from two-material decomposition, the proposed provides a more accurate and robust imaging biomarker of potential pulmonary perfusion defects.
Supplementary Material
ACKNOWLEDGMENTS
This work is partially supported by the National Institutes of Health under grants R01HL153594, U01EB021183-04S1, and 3R01EB020521-04S1.
Funding information
National Institutes of Health, Grant/Award Numbers: R01HL153594, U01EB021183-04S1, 3R01EB020521-04S1
APPENDIX I: PULMONARY PERFUSED BLOOD VOLUME
Using the relationship between mass, mass density, and volume, the PBV formula in Equation (1) can be recast to
| (S1) |
where Vcap(x)∕Vlung(x) denotes the volume fraction of the capillary bed in the VOI at x. When the iodinated contrast medium is injected into the blood stream and the pulmonary capillary bed is perfused with the iodinated blood, the mass of iodine that flows into the VOI in the lung is the same mass of iodine in the capillary bed, namely,
| (S2) |
However, the mass of iodine in the capillary bed is given by the product of iodine concentration in the input artery, ,and the volume of the capillary bed in the VOI, Vcap(x), i.e.,
| (S3) |
Therefore, the averaged concentration of iodinated blood in the lung tissue VOI is given by
| (S4) |
This formula can be re-arranged to obtain the ratio of the capillary bed in the lung tissue VOI as the ratio between the iodine concentration in the VOI and the iodine concentration in the input artery as follows:
| (S5) |
By combining Equations (S1) and (S5), the following equation is obtained for PBV:
| (S6) |
This is the primary result presented in Equation (2) in the main text.
APPENDIX II: PBV MEASUREMENT USING DECT IMAGING
In DECT-based lung perfusion assessment, the iodine basis image, aI(x), is used as a surrogate for iodine concentration ρI(x). The problem with this approach is that the physical meaning of aI(x) is not the same as ρI(x). Instead, its formula is given by40,41
| (S7) |
In which, Zeff is defined as
| (S8) |
Here Zi is the atomic number of the ith constituent material in the VOI at x, and fi is the fraction of electrons associated with the ith material. As shown in Equation (S7), aI(x) is not necessarily the same as ρI(x).They are equal only in the following special case:
Special case: The VOI is entirely composed of iodine and water. Under this special condition,
| (S9) |
where fI denotes the fraction of electrons coming from the iodine atoms. Under the condition in Equation (S9), the formula of aI(x) in Equation (S7) can be written as:
| (S10) |
Aside from the above special case, aI(x) is not the same as ρI(x).To find an alternative way to estimate PBV, the Zeff formula in Equation (S8) can be recast into the following form:
| (S11) |
where fj (j = 2, … n) denotes the electron fraction for non-iodine materials in the VOI. As shown in Table 1, the atomic numbers of non-iodine materials in the lung are relatively similar to Zw and are much smaller than ZI. As a result, the following approximation can be justified:
| (S12) |
Therefore,
| (S13) |
Per the definition of electron fraction, fI(x) can be written as
| (S14) |
where we used the fact that for the majority of tissue materials, Z∕A ≈ 1∕2. Based on both Equations (S13) and (S14):
| (S15) |
The mass of iodine in the VOI, mI(x), is related to Vcap(x) and by
| (S16) |
According to Equations (S15) and (S16) and the PBV formula in Equation (S1),
| (S17) |
This is the desired result presented in Equations (8) and (9) in the main text.
By comparing the formula of in Equation (S17) with the formula of aI(x) in Equation (S7), one can observe that and aI(x) are related by
| (S18) |
Therefore, an alternative method to calculate is to normalize the iodine material image aI(x) by the electron density image ρe(x) and then scale the result by .
Footnotes
CONFLICT OF INTEREST
The authors declare no conflict to disclose.
SUPPORTING INFORMATION
Additional supporting information may be found in the online version of the article at the publisher’s website.
DATA AVAILABILITY STATEMENT
The data supporting the results of this study are available upon reasonable request to the corresponding author.
REFERENCES
- 1.Hubbell JH, Seltze SM.X-ray mass attenuation coefficients. NIST Standard Reference Database 126. 2004. [Google Scholar]
- 2.Yang NC, Leichner PK, Hawkins WG. Effective atomic numbers for low-energy total photon interactions in human tissues. Med Phys. 1987;14(5):759–766. [DOI] [PubMed] [Google Scholar]
- 3.Kim YS. Human tissues – chemical composition and photon dosimetry data. Radiat Res. 1974;57(1):38–45. [PubMed] [Google Scholar]
- 4.Hachenberg T, Lundquist H, Tokics L, Brismar B, Hedenstierna G. Analysis of lung density by computed tomography before and during general anaesthesia. Acta Anaesthesiol Scand. 1993;37(6):549–555. [DOI] [PubMed] [Google Scholar]
- 5.Di Nisio M, van Es N, Büller HR. Deep vein thrombosis and pulmonary embolism. Lancet North Am Ed. 2016;388(10063):3060–3073. [DOI] [PubMed] [Google Scholar]
- 6.ACR. American College of Radiology Appropriateness Criteria®: acute chest pain—suspected pulmonary embolism. 2006. [PubMed]
- 7.Albrecht MH, Bickford MW. State-of-the-art pulmonary CT angiography for acute pulmonary embolism. AJR Am J Roentgenol. 2017;208(3):495–504. [DOI] [PubMed] [Google Scholar]
- 8.Wittram C, Maher MM, Yoo AJ, Kalra MK, Shepard JAO, McLoud TC. CT angiography of pulmonary embolism: diagnostic criteria and causes of misdiagnosis.Radiographics.2004;24(5):1219–1238. [DOI] [PubMed] [Google Scholar]
- 9.Burge AJ, Freeman KD, Klapper PJ, Haramati LB. Increased diagnosis of pulmonary embolism without a corresponding decline in mortality during the CT era. Clin Radiol. 2008;63(4):381–386. [DOI] [PubMed] [Google Scholar]
- 10.Budoff MJ, Dowe D, Jollis JG, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease. J Am Coll Cardiol. 2008;52(21):1724–1732. [DOI] [PubMed] [Google Scholar]
- 11.Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med. 2008;359(22):2324–2336. [DOI] [PubMed] [Google Scholar]
- 12.Redberg RF, Walsh J. Pay now, benefits may follow–the case of cardiac computed tomographic angiography. N Engl J Med. 2008;359(22):2309–2311. [DOI] [PubMed] [Google Scholar]
- 13.Phillips JJ, Straiton J, Staff RT. Planar and SPECT ventilation/perfusion imaging and computed tomography for the diagnosis of pulmonary embolism: a systematic review and meta-analysis of the literature, and cost and dose comparison. Eur J Radiol. 2015;84(7):1392–1400. [DOI] [PubMed] [Google Scholar]
- 14.Moore AJE, Wachsmann J, Chamarthy MR, Panjikaran L, Tanabe Y, Rajiah P. Imaging of acute pulmonary embolism: an update. Cardiovasc Diagn Ther. 2018;8(3):225–243. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Devaraj A, Sayer C, Sheard S, Grubnic S, Nair A, Vlahos I. Diagnosing acute pulmonary embolism with computed tomography: imaging update. J Thorac Imag. 2015;30(3):176–192. [DOI] [PubMed] [Google Scholar]
- 16.Hartmann IJ, Wittenberg R, Schaefer-Prokop C. Imaging of acute pulmonary embolism using multi-detector CT angiography: an update on imaging technique and interpretation. Eur J Radiol. 2010;74(1):40–49. [DOI] [PubMed] [Google Scholar]
- 17.Remy-Jardin M, Pistolesi M, Goodman LR, et al. Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology. 2007;245(2):315–329. [DOI] [PubMed] [Google Scholar]
- 18.Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA. 2007;298(3):317–323. [DOI] [PubMed] [Google Scholar]
- 19.McCollough CH, Primak AN, Saba O, et al. Dose performance of a 64-channel dual-source CT scanner.Radiology.2007;243(3):775–784. [DOI] [PubMed] [Google Scholar]
- 20.Stolzmann P, Scheffel H, Schertler T, et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol. 2008;18:592–599. [DOI] [PubMed] [Google Scholar]
- 21.Wildberger JE, Schoepf UJ, Mahnken AH, et al. Approaches to CT perfusion imaging in pulmonary embolism. Semin Roentgenol. 2005;40(1):64–73. [DOI] [PubMed] [Google Scholar]
- 22.Renapurkar RD, Bolen MA, Shrikanthan S, et al. Comparative assessment of qualitative and quantitative perfusion with dual-energy CT and planar and SPECT-CT V/Q scanning in patients with chronic thromboembolic pulmonary hypertension. Cardiovasc Diagn Ther. 2018;8(4):414–422. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Pontana F, Faivre JB, Remy-Jardin M, et al. Lung perfusion with dual-energy multidetector-row CT (MDCT):feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol. 2008;15(12):1494–1504. [DOI] [PubMed] [Google Scholar]
- 24.Okada M, Kunihiro Y, Nakashima Y, et al. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism. Eur J Radiol.2015;84(1):172–177. [DOI] [PubMed] [Google Scholar]
- 25.Kunihiro Y, Okada M, Matsunaga N. Evaluation of a proper cutoff value on quantitative dual-energy perfusion CT for the assessment of acute pulmonary thromboembolism. Acta Radiol. 2017;58(9):1061–1067. [DOI] [PubMed] [Google Scholar]
- 26.Kong WF, Wang YT, Yin LL, Pu H, Tao KY. Clinical risk stratification of acute pulmonary embolism: comparing the usefulness of CTA obstruction score and pulmonary perfusion defect score with dual-energy CT. Int J Cardiovasc Imag. 2017;33(12):2039–2047. [DOI] [PubMed] [Google Scholar]
- 27.Im DJ, Hur J, Han KH, et al. Acute pulmonary embolism: retrospective cohort study of the predictive value of perfusion defect volume measured with dual-energy CT. AJR Am J Roentgenol. 2017;209(5):1015–1022. [DOI] [PubMed] [Google Scholar]
- 28.Rassouli N,Etesami M,Dhanantwari A, Rajiah P. Detector-based spectral CT with a novel dual-layer technology: principles and applications. Insights Imag. 2017;8(6):589–598. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Sakamoto A, Sakamoto I, Nagayama H, Koike H, Sueyoshi E, Uetani M. Quantification of lung perfusion blood volume with dual-energy CT: assessment of the severity of acute pulmonary thromboembolism. AJR Am J Roentgenol. 2014;203(2):287–291. [DOI] [PubMed] [Google Scholar]
- 30.Zhang L-J, Chai X, Wu S-Y, et al. Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits. Eur Radiol. 2009;19(12):2844. [DOI] [PubMed] [Google Scholar]
- 31.Zhang L-J, Zhao Y-E, Wu S-Y, et al. Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology. 2009;252(1):61–70. [DOI] [PubMed] [Google Scholar]
- 32.Chae EJ, Seo JB, Jang YM, et al. Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. Am J Roentgenol. 2010;194(3):604–610. [DOI] [PubMed] [Google Scholar]
- 33.Bauer RW, Kerl JM, Weber E, et al. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism&–influence of window settings on the diagnosis of underlying pathologies of perfusion defects. Eur J Radiol. 2011;80(3):e476–e482. [DOI] [PubMed] [Google Scholar]
- 34.Lu GM, Zhao YE, Zhang LJ, Schoepf UJ. Dual-energy CT of thelung. Am J Roentgenol. 2012;199(5_supplement):S40–S53. [DOI] [PubMed] [Google Scholar]
- 35.Ko JP, Brandman S, Stember J, Naidich DP. Dual-energy computed tomography: concepts, performance, and thoracic applications. J Thorac Imag. 2012;27(1):7–22. [DOI] [PubMed] [Google Scholar]
- 36.Rajiah P Dual-energy computed tomography in thoracic imaging—current practices and utility: survey of the Society of Thoracic Radiology. J Thorac Imag. 2020;35(2):W43–W50. [DOI] [PubMed] [Google Scholar]
- 37.Le Berre A, Boeken T, Caramella C, et al. Dual-energy CT angiography reveals high prevalence of perfusion defects unrelated to pulmonary embolism in COVID-19 lesions. Insights Imag. 2021;12(1):24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Pontana F, Remy-Jardin M, Duhamel A, Faivre J-B, Wallaert B, Remy J. Lung perfusion with dual-energy multi-detector row CT: can it help recognize ground glass opacities of vascular origin? Acad Radiol. 2010;17(5):587–594. [DOI] [PubMed] [Google Scholar]
- 39.Poschenrieder F, Meiler S, Lubnow M, et al. Severe COVID-19 pneumonia: perfusion analysis in correlation with pulmonary embolism and vessel enlargement using dual-energy CT data. PLoS One. 2021;16(6):e0252478. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Alvarez RE, Macovski A. Energy-selective reconstructions in X-ray computerised tomography. Phys Med Biol. 1976;21(5):733–744. [DOI] [PubMed] [Google Scholar]
- 41.Lehmann LA, Alvarez RE, Macovski A, et al. Generalized image combinations in dual KVP digital radiography. Med Phys. 1981;8(5):659–667. [DOI] [PubMed] [Google Scholar]
- 42.McCollough CH, Boedeker K, Cody D, et al. Principles and applications of multienergy CT: report of AAPM Task Group 291.Med Phys. 2020;47(7):e881–e912. [DOI] [PubMed] [Google Scholar]
- 43.Murty RC. Effective atomic numbers of heterogeneous materials. Nature. 1965;207(4995):398–399. [Google Scholar]
- 44.Spiers FW. Effective atomic number and energy absorption in tissues. Brit J Radiol. 1946;19(218):52–63. [DOI] [PubMed] [Google Scholar]
- 45.Yuan A, Yang P-C, Lee L, et al. Reactive pulmonary artery vasoconstriction in pulmonary consolidation evaluated by color Doppler ultrasonography. Ultrasound Med Biol. 2000;26(1):49–56. [DOI] [PubMed] [Google Scholar]
- 46.Elojeimy S, Cruite I, Bowen S, Zeng J, Vesselle H. Overview of the novel and improved pulmonary ventilation-perfusion imaging applications in the era of SPECT/CT. AJR Am J Roentgenol. 2016;207(6):1307–1315. [DOI] [PubMed] [Google Scholar]
- 47.Ridge CA, Desai SR, Jeyin N, et al. Dual-energy CT pulmonary angiography quantifies vasculopathy in severe COVID-19 pneumonia. Radiol Cardiothorac Imag. 2020;2(5):e200428. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Afat S, Othman AE, Nikolaou K, Gassenmaier S. Dual-energy computed tomography of the lung in COVID-19 patients: mismatch of perfusion defects and pulmonary opacities. Diagnostics. 2020;10(11):870. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The data supporting the results of this study are available upon reasonable request to the corresponding author.







