An 83-year-old woman presented to our clinic with a persistent wound drainage after removal of a baker's cyst located in her right knee. She underwent total knee arthroplasty (TKA) 6 months prior and had several weeks of discomfort in the popliteal region. Magnetic resonance imaging of the knee showed a large baker's cyst with a slightly enhanced synovial signal in the knee. Open removal of the baker's cyst was performed. The wound did not heal after surgery, and a revision was performed 12 d later. Biopsy samples were obtained, and empiric antibiotic treatment with amoxicillin/clavulanate was started. Serratia marcescens grew in three out of three biopsy samples, and antibiotic therapy was streamlined to intravenous cefepime. A total of 7 d later, treatment was switched to oral ciprofloxacin. The patient was then referred to our institution due to persistent compromised wound healing in the setting of presumed superficial infection, which possibly required a muscle flap.
On physical examination, there were no local signs of inflammation, though watery fluid secretion from the popliteal wound was observed. Periprosthetic joint infection (PJI) was diagnosed based on the presence of the draining sinus near the prosthetic implant. Diagnostic arthrocentesis with an arthrography (methylene blue and contrast medium injection into the knee) was performed. The dispersion of the radiopaque substance under fluoroscopy is illustrated in Fig. 1a. The next day, the leakage of methylene blue through the popliteal wound was observed (Fig. 1b and c), proving the communication to the knee joint.
Figure 1.

(a) Dispersion of the contrast medium under fluoroscopy. (b, c) Leakage of methylene blue through the popliteal wound. © University Hospital of Basel.
Surgical site infection can be categorized as being superficial, deep and organ/space (National Healthcare Safety Network, 2021). However, this categorization is inappropriate when there is an implant in place. A superficial wound infection over a foreign body is an implant-associated infection until proven otherwise (Berbari et al., 1998). The use of intra-articular methylene blue dye is an old fashioned, but still useful, method to confirm the extent of a sinus tract (Ziv et al., 2009).
Disclaimer
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Ethical statement
The patient gave informed consent to publish the case and her pictures.
Data availability
No data sets were used in this article.
Author contributions
SMH, PS and MC drafted the initial work and reviewed and revised the paper. All authors approved the final paper, as submitted, and agreed to be accountable for all aspects of the work.
Competing interests
Some authors are members of the editorial board of . The peer-review process was guided by an independent editor, and the authors have also no other competing interests to declare. Martin Clauss is the treasurer of the European Bone and Joint Infection Society (EBJIS).
Review statement
This paper was edited by Bryan Springer and reviewed by two anonymous referees.
References
- Berbari EF, Hanssen AD, Duffy MC, Steckelberg JM, Ilstrup DM, Harmsen WS, Osmon DR. Risk Factors for Prosthetic Joint Infection: Case-Control Study. Clin Infect Dis. 1998;27:1247–1254. doi: 10.1086/514991. [DOI] [PubMed] [Google Scholar]
- Surgical Site Infection Event (SSI) [Internet] National Healthcare Safety Network; [3 November 2021]. 2021. available at: https://www.cdc.gov/nhsn/pdfs/pscmanual/9pscssicurrent.pdf . [Google Scholar]
- Ziv YB, Kardosh R, Debi R, Backstein D, Safir O, Kosashvili Y. An Inexpensive and Accurate Method for Hip Injections Without the Use of Imaging. J Clin Rheumatol. 2009;15:103–105. doi: 10.1097/RHU.0b013e318190fa20. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
No data sets were used in this article.