Skip to main content
Journal of Clinical Medicine logoLink to Journal of Clinical Medicine
. 2021 Nov 25;10(23):5524. doi: 10.3390/jcm10235524

Efficacy and Safety of Video-Laryngoscopy versus Direct Laryngoscopy for Double-Lumen Endotracheal Intubation: A Systematic Review and Meta-Analysis

Katarzyna Karczewska 1, Szymon Bialka 2, Jacek Smereka 3,4, Maciej Cyran 4,5, Grazyna Nowak-Starz 6, Jaroslaw Chmielewski 7, Michal Pruc 4, Pawel Wieczorek 4,8, Frank William Peacock 9, Jerzy Robert Ladny 10, Lukasz Szarpak 4,11,*
Editor: Daniel L Herr
PMCID: PMC8658072  PMID: 34884226

Abstract

The available meta-analyses have inconclusively indicated the advantages of video-laryngoscopy (VL) in different clinical situations; therefore, we conducted a systematic review and meta-analysis to determine efficacy outcomes such as successful first attempt or time to perform endotracheal intubation as well as adverse events of VL vs. direct laryngoscopes (DL) for double-lumen intubation. First intubation attempt success rate was 87.9% for VL and 84.5% for DL (OR = 1.64; 95% CI: 0.95 to 2.86; I2 = 61%; p = 0.08). Overall success rate was 99.8% for VL and 98.8% for DL, respectively (OR = 3.89; 95%CI: 0.95 to 15.93; I2 = 0; p = 0.06). Intubation time for VL was 43.4 ± 30.4 s compared to 54.0 ± 56.3 s for DL (MD = −11.87; 95%CI: −17.06 to −6.68; I2 = 99%; p < 0.001). Glottic view based on Cormack–Lehane grades 1 or 2 equaled 93.1% and 88.1% in the VL and DL groups, respectively (OR = 3.33; 95% CI: 1.18 to 9.41; I2 = 63%; p = 0.02). External laryngeal manipulation was needed in 18.4% cases of VL compared with 42.8% for DL (OR = 0.28; 95% CI: 0.20 to 0.40; I2 = 69%; p < 0.001). For double-lumen intubation, VL offers shorter intubation time, better glottic view based on Cormack–Lehane grade, and a lower need for ELM, but comparable first intubation attempt success rate and overall intubation success rate compared with DL.

Keywords: double-lumen tube, endotracheal intubation, one-lung ventilation, systematic review, meta-analysis, randomized controlled trials

1. Introduction

The increasing development of thoracoscopic procedures is inevitably associated with the use of single-lung ventilation. Such a strategy allows, on one hand, to expose the surgical field while maintaining ventilation of the non-operated lung [1]. One of several methods of providing single-lung ventilation, currently considered the gold standard, is the use of double-lumen endotracheal tubes (DLTs) [2]. The application of DLTs, due to their large diameter or the need for a rotational insertion technique, is associated with a significant risk of prolonged intubation, intubation failure, and airway trauma [3,4]. On the other hand, studies have confirmed that the use of video-laryngoscopes (VL), compared with traditional laryngoscopy, improves the visibility of anatomical structures during intubation [5]. VLs facilitate intubation with a traditional tube in cases of both “normal” and difficult airways [6]. However, the available meta-analyses have inconclusively indicated the advantages of VL in different clinical situations [7,8,9,10].

Therefore, we conducted this systematic review and meta-analysis to determine the efficacy outcomes such as successful first attempt and time to perform endotracheal intubation as well as adverse events of VLs vs. direct laryngoscopes (DL) for double-lumen intubation.

2. Materials and Methods

This systematic review and meta-analysis was performed in accordance with the criteria outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement (Table S2) [11]. Due to the study design (meta-analysis), neither institutional review board approval nor patient informed consents were required.

2.1. Search Strategy

Two reviewers (KK and JS) independently performed a comprehensive literature search using the PubMed, Scopus, Web of Science, and Cochrane Central Register of Controlled Trials databases. The most recent search was conducted on 30 September 2021. Terms related to double-lumen endotracheal intubation were applied: “double-lumen”, “laryngoscopy”, “video-laryngoscopy”, and “direct laryngoscopy”. Additionally, we performed a manual search and review of the references listed in the retrieved articles. All references were saved in an EndNote (EndNote, Inc., Philadelphia, PA, USA) library used to identify duplicates.

2.2. Study Selection Criteria

The studies included in this meta-analysis met the following PICOS criteria: (1) Participants: intubated adult patients; (2) Intervention: endotracheal intubation by using a DLT with video-laryngoscopes; (3) Comparison: endotracheal intubation by using a DLT with Macintosh direct laryngoscope; (4) Outcomes: detailed information concerning first intubation attempt success rate, overall intubation success rate, intubation time, glottic view, external laryngeal manipulation (ELM), and adverse events; and (5) Study design: randomized controlled trials. The exclusion criteria were as follows: (1) studies involving pediatric patients; (2) non-RCTs; (3) editorials; (4) conference abstracts; and (5) guidelines.

2.3. Data Extraction

Two reviewers (MC and KK) independently extracted data from the identified eligible studies by using a specifically designed data extraction form in Microsoft ExcelTM (Microsoft Corp., Redmond, WA, USA). Another author cross-checked these data before analysis (LS).

The following data were extracted from each study: first intubation attempt success rate, overall intubation success rate, intubation time, glottic view, and ELM. We also analyzed the adverse events that occurred during tracheal intubation. Where there were suspected discrepancies in the data, we contacted the relevant authors directly.

2.4. Risk of Assessment Bias

We applied a revised tool to assess the risk of bias in randomized trials (RoB-2) [12] to evaluate the risk of bias of the included studies. The RoB-2 tool examines five bias domains: (1) bias arising from the randomization process; (2) bias due to deviations from intended intervention; (3) bias due to missing outcome data; (4) bias in the measurement of the outcome; and (5) bias in the selection of the reported results. The risk of bias in each of these domains can be rated as “high”, “some concerns”, or “low”. The overall RoB-2 judgment at the domain and study level was attributed in accordance with the criteria specified in the RobVis tool [13]. The risk of bias was determined independently by two reviewers (KK and MC); disagreements were resolved by a third reviewer (LS) if necessary.

2.5. Statistical Analysis

The meta-analysis was entirely conducted with Review Manager software, version 5.4 (Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark) and the Stata 14 software (StataCorp. LP, College Station, TX, USA). The significance level for all statistical tests was p <  0.05 (two-tailed). For dichotomous data, we used odds ratios (ORs) as the effect measure with 95% confidence intervals (CIs), and for continuous data, we applied mean differences (MDs) with 95% CI. When a continuous outcome was reported in a study as median, range, and interquartile range, we estimated means and standard deviations with the use of a formula described by Hozo et al. [14]. For meta-analysis, we utilized the random effects model (assuming a distribution of effects across studies) to weigh estimates of studies in proportion to their significance [15]. Heterogeneity was determined with the I2 statistic, in which the results ranged from 0% to 100%. Heterogeneity was interpreted as not observed when I2 = 0%, low when I2 = 25%, medium when I2 = 50%, and high when I2 = 75% [16,17].

Subgroup analyses were performed on first intubation success rate, overall success rate, time to intubation; glottic view, and ELM were investigated by separating the VL types. Videolaryngoscopes, depending on the construction, were divided into the following groups: Macintosh blade VLs, channeled VLs, and video-tubes and scopes.

3. Results

3.1. Characteristics of Studies Included in the Meta-Analysis

The initial literature search yielded 761 citations, and further two citations were identified through manual citation and a reference search of relevant articles (Figure 1). After excluding duplicate studies, 539 articles remained. After screening the titles and abstracts of all the retrieved articles, 473 papers were excluded. Then, the full texts were reviewed, and 32 studies were excluded because they did not involve Macintosh direct laryngoscope as a comparator group, consisted of manikin trials, involved different interventions, or were reviews or meta-analyses. Ultimately, 25 studies [18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42] published in the period of 2010–2021 were included in this meta-analysis.

Figure 1.

Figure 1

Database search and selection of studies according to PRISMA guidelines.

These 25 studies included 2154 adult patients (Table 1 and Table S1). A detailed characterization of the patients in the VL and DL groups is presented in Supplementary Digital File in Table S3 and Figures S1 and S2. Each study was screened for risk of bias and for methodological quality with the Cochrane Collaboration’s tool for assessing the risk of bias (Figures S5 and S6). All studies met the criteria for high-quality randomized controlled trials.

Table 1.

Summary characteristics of the included studies.

Study Country Study Design Intubation Method No. of
Patients
Age Sex, Male BMI ASA
I or II
Bakshi et al., 2019 India RCT McGrath 37 46.9 (17) 25 (67.6%) 21.8 (3) 37 (100%)
Macintosh 37 49.8 (16) 23 (62.2%) 23.0 (3) 37 (100%)
Bensghir et al., 2010 France RCT X-Lite 34 41.8 (9) 28 (82.3%) 24 (2.9) 34 (100%)
Macintosh 34 44.6 (10) 29 (85.3%) 22.98 (2.19) 34 (100%)
Chen et al., 2017 China RCT Disposcope 27 59.5 (12.9) 9 (33.3%) 24.3 (3.0) NS
Macintosh 27 61.0 (11.4) 11 (40.7%) 23.8 (3.1) NS
El-Tahan et al., 2018 Saudi Arabia RCT GlideScope 34 39.9 (17.52) 26 (76.5%) NS 20 (58.8%)
Airtraq 35 33.8 (13.37) 31 (88.6%) NS 19 (54.3%)
KingVision 32 31.3 (14.8) 27 (84.4%) NS 20 (62.5%)
Macintosh 32 27.5 (9.83) 19 (59.4%) NS 22 (68.8%)
Hamp et al., 2015 Austria RCT Airtraq 17 56.8 (10.6) 9 (52.9%) NS 16 (94.1%)
Macintosh 20 63.4 (9.3) 11 (55.0%) NS 18 (90.0%)
Heir et al., 2018 USA RCT ETView 38 NS 28 (73.7%) 29.8 NS
Macintosh 42 NS 19 (45.2%) 27.0 NS
Hsu et al., 2012 Taiwan RCT GlideScope 30 40.1 (18.7) 7 (23.3%) 21.3 (3.4) 30 (100%)
Macintosh 30 37.2 (15.4) 11 (36.7%) 23.0(5.6) 30 (100%)
Hsu et al., 2013 Taiwan RCT Trachway stylet 30 40 (15) 20 (66.7%) 21 (4) NS
Macintosh 30 47 (15) 22 (73.3%) 23 (4) NS
Huang et al., 2020 China RCT GlideScope 29 58.45 (8.8) 11 (37.9%) 23.33 (3.29) 29 (100%)
C-MAC 30 57.2 (9.6) 18 (60.0%) 22.82 (2.67) 30 (100%)
Macintosh 30 54.57 (11.78) 20 (66.7%) 24.32 (3.78) 30 (100%)
Kido et al., 2015 Japan RCT McGrath 25 66.6 (11.3) 15 (60.0%) 22.3 (3.2) 13 (52.0%)
Macintosh 25 67.9 (15.0) 16 (64.0%) 21.9 (4.6) 11 (44.0%)
Levy-Faber et al., 2015 Izrael RCT VivaSight 35 68 (61–74) 21 (60.0%) NS 19 (54.3%)
Macintosh 36 67 (61–75) 18 (50.0%) NS 20 (55.6%)
Lin et al., 2012 China RCT CEL-100 83 58.2 (9.6) 55 (66.3%) 22.9 (2.7) 76 (91.6%)
Macintosh 82 57.6 (9.4) 52 (63.4%) 23.1 (2.8) 76 (92.7%)
Liu et al., 2018 China RCT VivaSight 26 39.5 (13.5) 16 (61.5%) 22.9 (3.1) NS
Macintosh 29 40.0 (13.3) 18 (62.1%) 23.6 (3.6) NS
Maharaj et al., 2006 Ireland RCT AirTraq 30 43.8 (16.8) 11 (36.7%) 27.1 (6.1) NS
Macintosh 30 41.1 (16.9) 11 (36.7%) 27.7 (5.7) NS
Mathew et al., 2021 India RCT C-MAC 44 36.3 29 (65.9%) 22.1 42 (95.5%)
Macintosh 43 40.4 28 (65.1%) 22.5 39 (90.7%)
Onifade et al., 2020 USA RCT VivaSight 25 55.3 (6.6) 11 (44.0%) 27.5 (2.8) 4 (16.0%)
Macintosh 25 53.5 (5.2) 13 (52.0%) 28.7 (1.6) 4 (16.0%)
Risse et al., 2020 Germany RCT GlideScope 34 66.3 (4.9) 25 (73.5%) 25.9 (1.4) 10 (29.4%)
Macintosh 31 59.3 (3.8) 25 (80.6%) 26.6 (1.9) 10 (32.3%)
Russell et al., 2013 Canada RCT GlideScope 35 59 (12) 15 (42.9%) 26 (5) 8 (22.9%)
Macintosh 35 62 (14) 18 (51.4%) 26 (4) 5 (14.3%)
Schuepbach et al., 2015 Switzerland RCT VivaSight 19 57 (17) 9 (47.4%) 23 (4) 11 (57.9%)
Macintosh 20 63 (10) 10 (50.0%) 24 (3) 8 (40.0%)
Shah et al., 2016 India RCT C-MAC 30 54.57 (11.06) 22 (73.3%) NS 30 (100%)
Macintosh 30 52.13 (12.69) 20 (66.7%) NS 30 (100%)
Wasem et al., 2013 Germany RCT AirTraq 30 63 (10) 22 (73.3%) 27.4 (2.8) 16 (53.3%)
Macintosh 30 55 (19) 19 (63.3%) 27.1 (6.2) 17 (56.7%)
Xu et al., 2015 China RCT SOS stylet 30 50.1 (11.1) 14 (46.7%) 23.4 (3.0) 26 (86.7%)
Macintosh 30 46.3 (16.1) 17 (56.7%) 24.0 (4.9) 27 (90.0%)
Yang et al., 2013 Republic of Korea RCT Optiscope 198 55.5 (9.7) 140 (70.7%) 23.2 (2.9) NS
Macintosh 199 56.5 (9.0) 150 (75.4%) 23.4 (3.1) NS
Yao et al., 2015 China RCT McGrath 48 47.6 (13.8) 33 (68.8%) 22.0 (3.4) 47 (97.9%)
Macintosh 48 47.8 (16.3) 33 (68.8%) 21.9 (3.0) 44 (91.7%)
Yi et al., 2013 China RCT GlideScope 35 NS NS NS NS
Macintosh 35 NS NS NS NS
Yao et al., 2018 Korea RCT McGrath 22 47.5 (2.9) 14 (63.6%) NS 22 (100%)
Macintosh 22 49.3 (2.6) 14 (63.6%) NS 22 (100%)

Legend: NS: Not specified; RCT: Randomized controlled trial.

3.2. First Intubation Attempt Success Rate

A total of 23 studies reported the first intubation attempt success rate. Pooled analysis revealed the first attempt success rate of 87.9% in VL compared with 84.5% for DL (OR = 1.64; 95% CI: 0.95 to 2.86; I2 = 61%; p = 0.08).

Subgroup analysis showed that the first intubation success rate for VL with a Macintosh shape blade compared with the standard Macintosh laryngoscope varied and amounted to 85.9% and 83.6%, respectively (OR = 1.93; 95% CI: 0.82 to 4.51; I2 = 72%; p = 0.13; Figure 2). In turn, intubation with video tubes or scopes was associated with a statistically significantly higher first intubation success rate than intubation with DL (91.5% vs. 84.9%) (OR = 1.86; 95% CI: 1.16 to 2.99; I2 = 0%; p = 0.01). An inverse relationship was observed in the subgroup of channeled laryngoscopes: intubation with these devices compared with DL was associated with a lower first intubation success rate (82.9% vs. 89.0%) (OR = 0.61; 95% CI: 0.15 to 2.45; I2 = 47%; p = 0.49).

Figure 2.

Figure 2

Forest plot of first intubation attempt success rate among video-laryngoscope and direct-laryngoscope groups. The center of each square represents the weighted odds ratios for individual trials, and the corresponding horizontal line stands for a 95% confidence interval. The diamonds represent pooled results. Legend: CI = confidence interval; DL = direct laryngoscopy; OD = odds ratio; VL = video-laryngoscopy.

3.3. Overall Intubation Success Rate

Overall success rate was reported in 16 studies and equaled 99.8% for VL and 98.8% for DL (OR = 3.89; 95% CI: 0.95 to 15.93; I2 = 0; p = 0.06).

Subgroup analysis established a 100% overall intubation success rate for VL with a Macintosh shaped blade and for DL. Additionally, for channeled laryngoscopes and DL comparison, the overall success rate was 100% in both groups. On the other hand, the overall success rate with video tubes and scopes turned out to be 99.4% compared with 97.5% for DL (OR = 3.89; 95% CI: 0.95 to 15.93; I2 = 0%; p = 0.06).

3.4. Intubation Time

Mean intubation time for VL equaled 43.4 ± 30.4 s and was statistically significantly shorter than that with DL: 54.0 ± 56.3 s (MD = −11.87; 95% CI: −17.06 to −6.68; I2 = 99%; p < 0.001).

In the Macintosh blade laryngoscope subgroup, mean time of intubation amounted to 55.7 ± 30.4 s for VL and 48.6 ± 21.2 s for DL (MD = 5.80; 95% CI: 1.60 to 10.01; I2 = 97%; p = 0.007; Figure 3). In the channeled laryngoscope subgroup, intubation time was 38.3 ± 31.0 s for VL compared with 40.1 ± 28.5 s for DL (MD = −0.90; 95% CI: −12.55 to 10.74; I2 = 87%; p = 0.88). In the subgroup of video tubes and scopes, mean intubation time with VL equaled 28.3 ± 22.2 s and was statistically significantly shorter than that with DL: 65 ± 82.2 s (MD = −59.17; 95% CI: −76.91 to −41.43; I2 = 100%; p < 0.001).

Figure 3.

Figure 3

Forest plot of time to intubation in video-laryngoscope and direct-laryngoscope groups. The center of each square represents the weighted mean differences for individual trials, and the corresponding horizontal line stands for a 95% confidence interval. The diamonds represent pooled results. Legend: CI = confidence interval; MD = mean difference.

3.5. Glottic View

Glottic view in accordance with Cormack–Lehane grade was reported in 15 studies. Good view, defined as Cormack–Lehane grade 1 or 2, varied in the VL and DL groups and equaled 93.1% and 88.1%, respectively (OR = 3.33; 95% CI: 1.18 to 9.41; I2 = 63%; p = 0.02).

In the Macintosh blade subgroup analysis, VL resulted in better visualization of the glottis than DL (96.5% vs. 87.8%) (OR = 5.40; 95% CI: 1.99 to 14.66; I2 = 45%; p < 0.001; Figures S3 and S4). The same relationship was observed in the channeled VL subgroup (75.6% vs. 63%, respectively) (OR = 4.78; 95% CI: 0.17 to 135.25; I2 = 80%; p = 0.36).

In the subgroup of video tubes and scopes, glottic visualization at Cormack–Lehane category grades 1–2 was observed in 92.9% for VL and 93.5% for DL (OR = 0.94; 95% CI: 0.30 to 2.99; I2 = 0%; p = 0.92).

3.6. External Laryngeal Manipulation

Ten studies reported ELM during the intubation process. Pooled analysis revealed that ELM was needed in 18.4% cases of VL compared with 42.8% in the DL group (OR = 0.28; 95% CI: 0.20 to 0.40; I2 = 69%; p < 0.001).

Subgroup analysis showed that ELM was less often required with VL than with DL in the Macintosh blade VL group (21.4% vs. 44.3%) (OR = 0.27; 95% CI: 0.12 to 0.60; I2 = 74%; p = 0.001), the channeled VL group (10.8% vs. 29.0%) (OR = 0.23; 95% CI: 0.03 to 1.97; I2 = 54%; p = 0.18), and the group of video tubes and scopes (0% vs. 46.7%) (OR = 0.02; 95% CI: 0.00 to 0.33; p = 0.007).

3.7. Adverse Events

Intubation with VL and DL exhibited a comparable rate of adverse events. A full list of the analyzed adverse events is presented in Table 2.

Table 2.

Pooled analysis of adverse events reported in the included trials.

Type of Adverse Event No. of Studies Events/Participants Events Heterogeneity between Trials p-Value for Differences across Groups
VL DL RR 95% CI p-Value I2
Statistic
Oral bleeding 10 35/400
(8.8%)
52/373 (13.9%) 0.67 0.37 to 1.20 0.14 34% 0.18
Blood on laryngoscope blade 5 10/180
(5.6%)
10/176
(5.7%)
0.93 0.33 to 2.65 0.29 19% 0.90
Bronchospasm 5 0/162
(0.0%)
4/163
(2.5%)
0.19 0.02 to 1.60 0.97 0% 0.13
Sore throat 15 149/640
(23.3%)
174/549
(31.7%)
0.86 0.67 to 1.09 <0.001 79% 0.22
Hoarseness 13 118/554
(21.3%)
140/459
(30.5%)
0.80 0.57 to 1.13 <0.001 83% 0.21
Desaturation 6 10/246
(4.1%)
24/241
(10.0%)
0.48 0.18 to 1.26 0.22 30% 0.13
Cardiac arrhythmia 3 6/98
(6.1%)
12/95
(12.6%)
0.52 0.17 to 1.56 0.28 16% 0.24
Lip trauma 3 4/170
(2.4%)
1/98
(10.2%)
2.07 0.34 to 12.76 0.57 0% 0.43
Dental trauma 6 0/290
(0.0%)
0/193
(0.0%)
NE NE NA NA NA
Esophageal intubation 4 0/187
(0.0%)
7/185
(3.8%)
0.13 0.02 to 0.98 0.90 0% 0.05
Cuff rupture 5 14/288
(4.9%)
14/217
(6.5%)
0.84 0.23 to 3.12 0.11 51% 0.80
Tube misplacement 5 30/190
(15.8%)
10/162
(6.2%)
1.99 0.94 to 4.19 0.35 8% 0.07

Legend: VL: video-laryngoscopy; DL: direct laryngoscopy; NE: not estimable; NA: not applicable; RR: risk ratio.

4. Discussion

The analysis of the success rate of the first intubation attempt, described in 26 studies (n = 2154), showed higher values in the VL group than for DL. However, there was no statistical significance, but only a trend toward significance (p = 0.07). These results contrasted with the data obtained by Liu et al., who investigated 1215 patients and confirmed a significant superiority of video devices (VL or video-stylet) over Macintosh laryngoscope (OR = 2.77; 95% CI: 1.92 to 4.00; p < 0.00001) [43]. The same authors showed no differences in subgroup analysis depending on the type of the video device used. In contrast, they maintained that intubation with video tubes or scopes was associated with a statistically significantly higher first attempt success rate than intubation with DL. An analysis of the total intubation success and failure rates revealed no significant differences between VL and DL (p = 006). However, the involved 17 randomized clinical trials exhibited low homogeneity values. Endotracheal intubation with DLTs, due to their specificity, is more difficult than that with standard equipment; therefore, it is important to maximize the probability of intubation, especially during the first attempt. For this purpose, the use of video tubes or scopes is recommended first.

One of the fundamental factors of perioperative safety is the duration of endotracheal intubation. Prolonged apnea time can lead to significant hypoxia with its consequences. Patients undergoing thoracic surgery are special cases. On one hand, they usually present with pulmonary diseases (e.g., chronic obstructive pulmonary disease, bronchial asthma, pneumoconiosis), which are initially associated with a high risk of hypoxemia and low oxygen reserve. As mentioned earlier, the use of DLT is a priori associated with prolonged intubation due to the device specificity. Our meta-analysis confirmed the superiority of VL over DL for significantly shorter DLT intubation times. It should be noted that differences in intubation time are unsure due to the very high heterogeneity of the data (I2 > 90%) and this problem also applies to other meta-analyses. Different data were provided by Liu et al., who demonstrated no significant difference in intubation time between any video device and the Macintosh laryngoscope [43]. This, as the authors themselves indicate, may have been influenced by a high level of heterogeneity when reporting intubation times across randomized controlled trials. In our study, as in the analysis by Kim et al., the use of video tubes or scopes was associated with significantly shorter intubation times [44].

The safety of endotracheal intubation and occurrence of adverse events are particularly influenced by the degree of laryngeal visualization and the need for external manipulation within the larynx. The use of VL allowed better glottic visualization (rated 1 and 2 on the Cormack–Lehane scale), and the need for ELM was described significantly less often. Subgroup analysis showed no need for ELM with video tubes or scopes.

DLT intubation involves several consecutive steps. First, the laryngeal entry is visualized; then, the bronchial tip is inserted behind the vocal cords; the tube is advanced toward the tracheal bifurcation; and, finally, the bronchial end of the tube is placed in the appropriate main bronchus [45]. The duration of this procedure is significantly longer than that of single-tube intubation and depends on many factors including visualization of the laryngeal entry. The technique is also associated with a higher risk of adverse events. Perioperative oral trauma with bleeding, damage to teeth and cheeks, distention, bronchospasm, and cardiac arrhythmias as well as postoperative sore throat and hoarseness are some of the complications related to endotracheal intubation [46,47]. During intubation with DLT, the risk of these complications is significantly higher, and esophageal intubation or tube displacement are particularly associated with this procedure [46]. In the material analyzed, DL was related to a higher risk of unintended esophageal intubation and, at the same time, a lower risk (but not statistically significant, p = 0.06) of tube misplacement. However, the homogeneity of the randomized controlled trials included in the study was low. The presented data are consistent with those provided by Liu et al., who confirmed that the use of VL was associated with a higher incidence of tube misplacement [43]. The occurrence of other adverse events such as oral bleeding, bronchospasm, sore throat, hoarseness, desaturation, cardiac arrhythmia, lip trauma, dental trauma, and cuff rupture was not associated with any of the intubation techniques used. These results, when compared with the available meta-analyses, are conflicting. In both studies by Liu et al. [43] and Kim et al. [44], the use of VL brought about a lower risk of intubation complications. Of these, the use of video-stylets was associated with a lower incidence of the described adverse events [44]. These discrepancies may be influenced by, among other factors, the lack of particular VL subgroup analysis in our study.

There are some limitations of our study that should be considered. These are due to several factors that affect the obtained results. The first limitation is the relatively small study group in most of the analyzed publications. Another problem is that in the majority of the publications, only patients with normal airways were included and studies were limited to a specific patient population. In some studies, intubation was performed by physicians experienced in endotracheal intubation. Another limitation is the use of specific types of DLTs. Moreover, it should be mentioned that due to the small number of studies using channeled-laryngoscopes, the conclusions on channeled-laryngoscopes were based on only 82 patients.

5. Conclusions

For double-lumen endotracheal intubation, VL offers shorter intubation time, better glottic view in accordance with Cormack–Lehane grade, and lower need for ELM, but comparable first intubation attempt success rate and overall intubation success rate compared with DL.

Acknowledgments

The study was supported by the ERC Research Net and by the Polish Society of Disaster Medicine.

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/jcm10235524/s1, Table S1: Methodology characteristics among the included trials, Table S2: PRISMA Checklist, Table S3: Polled analysis of patient characteristics, Figure S1: Distribution of American Society of Anesthesiologists grades among 1305 patients, Figure S2: Distribution of Mallampati class among 1795 patients, Figure S3: Forest plot of Cormack–Lehane grades 1 or 2 in video-laryngoscope and direct-laryngoscope groups, Figure S4: Distribution of glottis visualization in Cormack–Lehane grades among 1500 patients, Figure S5: A summary table of the review authors’ judgements for each risk of bias item for each randomized study, Figure S6: A plot of the distribution of the review authors’ judgements across randomized studies for each risk of bias item.

Author Contributions

Conceptualization, K.K. and L.S.; Methodology, K.K. and L.S.; Software, J.C. and G.N.-S.; Validation, L.S., J.S. and K.K.; Formal analysis, K.K., S.B. and J.R.L.; Investigation, K.K., L.S., M.P. and P.W.; Resources, L.S. and M.C.; Data curation, K.K. and L.S.; Writing—original draft preparation, K.K., S.B., J.S. and L.S.; Writing—review and editing, F.W.P. and the rest of the authors; Visualization, K.K. and L.S.; Supervision, L.S.; Project administration, K.K.; Funding acquisition, J.R.L. and L.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Rapchuk I.L., Kunju S., Smith I.J., Faulke D.J. A six-month evaluation of the VivaSightTM video double-lumen endotracheal tube after introduction into thoracic anaesthetic practice at a single institution. Anaesth. Intensive Care. 2017;45:189–195. doi: 10.1177/0310057X1704500208. [DOI] [PubMed] [Google Scholar]
  • 2.Karczewska K., Smereka J., Szarpak L., Ruetzler K., Bialka S. Efficacy of double-lumen intubation performed by paramedics on patients with lung damage. Experimental, pilot simulation trial. Disaster Emerg. Med. J. 2020;5:7–11. doi: 10.5603/DEMJ.a2020.0001. [DOI] [Google Scholar]
  • 3.Zhong T., Wang W., Chen J., Ran L., Story D.A. Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: A randomized, prospective trial. Anaesth. Intensive Care. 2009;37:441–446. doi: 10.1177/0310057X0803600601. [DOI] [PubMed] [Google Scholar]
  • 4.Liu H., Jahr J.S., Sullivan E., Waters P.F. Tracheobronchial rupture after double-lumen endotracheal intubation. J. Cardiothorac. Vasc. Anesth. 2004;18:228–233. doi: 10.1053/j.jvca.2004.01.003. [DOI] [PubMed] [Google Scholar]
  • 5.Smereka J., Ladny J.R., Naylor A., Ruetzler K., Szarpak L. C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: A manikin trial. Am. J. Emerg. Med. 2017;35:1142–1146. doi: 10.1016/j.ajem.2017.03.030. [DOI] [PubMed] [Google Scholar]
  • 6.Szarpak L., Smereka J., Ladny J.R. Comparison of Macintosh and Intubrite laryngoscopes for intubation performed by novice physicians in a difficult airway scenario. Am. J. Emerg. Med. 2017;35:796–797. doi: 10.1016/j.ajem.2017.01.005. [DOI] [PubMed] [Google Scholar]
  • 7.Suppan L., Tramer M.R., Niquille M., Grosgurin O., Marti C. Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: Systematic review and meta-analysis of randomized controlled trials. Br. J. Anaesth. 2016;116:27–36. doi: 10.1093/bja/aev205. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Sun Y., Lu Y., Huang Y., Jiang H. Pediatric video laryngoscope versus direct laryngoscope: A meta-analysis of randomized controlled trials. Pediatr. Anesth. 2014;24:1056–1065. doi: 10.1111/pan.12458. [DOI] [PubMed] [Google Scholar]
  • 9.De Jong A., Molinari N., Conseil M., Coisel Y., Pouzeratte Y., Belafia F., Jung B., Chanques G., Jaber S. Video laryngoscopy versus direct laryngoscopy for orotracheal intubation in the intensive care unit: A systematic review and meta-analysis. Int. Care Med. 2017;40:629–639. doi: 10.1007/s00134-014-3236-5. [DOI] [PubMed] [Google Scholar]
  • 10.Maslanka M., Smereka J., Proc M., Robak O., Attila K., Szarpak L., Ruetzler K. Airtraq® versus Macintosh laryngoscope for airway management during general anesthesia: A systematic review and meta-analysis of randomized controlled trials. Disaster Emerg. Med. J. 2021;6:1–9. doi: 10.5603/DEMJ.a2021.0001. [DOI] [Google Scholar]
  • 11.Page M.J., McKenzie J.E., Bossuyt P.M., Boutron I., Hoffmann T.C., Mulrow C.D., Shamseer L., Tetzlaff J.M., Akl E.A., Brennan S.E., et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. doi: 10.1136/bmj.n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Sterne J.A.C., Savović J., Page M.J., Elbers R.G., Blencowe N.S., Boutron I., Cates C.J., Cheng H.-Y., Corbett M.S., Eldridge S.M., et al. RoB 2: A revised tool for assessing risk of bias in randomized trials. BMJ. 2019;366:l4898. doi: 10.1136/bmj.l4898. [DOI] [PubMed] [Google Scholar]
  • 13.McGuinness L.A., Higgins J.P.T. Risk-of-bias VISualization (robvis): An R package and Shiny web app for visualizing risk-of-bias assessments. Res. Syn. Meth. 2020;12:55–61. doi: 10.1002/jrsm.1411. [DOI] [PubMed] [Google Scholar]
  • 14.Hozo S.P., Djulbegovic B., Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med. Res. Methodol. 2005;5:13. doi: 10.1186/1471-2288-5-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Cochrane Cochrane Handbook for Systematic Reviews of Interventions. 2019. [(accessed on 1 July 2019)]. Available online: www.training.cochrane.org/handbook.
  • 16.Higgins J.P.T., Thompson S.G., Deeks J.J., Altman D.G. Measuring inconsistency in meta-analyses. BMJ. 2003;327:557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Szarpak L., Rafique Z., Gasecka A., Chirico F., Gawel W., Hernik J., Kaminska H., Filipiak K.J., Jaguszewski M.J., Szarpak L. A systematic review and meta-analysis of effect of vitamin D levels on the incidence of COVID-19. Cardiol. J. 2021;28:647–654. doi: 10.5603/CJ.a2021.0072. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Bakshi S.G., Gawri A., Divat J.V. McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes: A randomised control trial. Indian J. Anaesth. 2019;63:456–461. doi: 10.4103/ija.IJA_48_19. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Bensghir M., Alaoui H., Azendour H., Drissi M., Elwali A., Meziane M., Lalaoui J.S., Akhaddar A., Kamili K.D. Faster double-lumen tube intubation with the videolaryngoscope than with a standard laryngoscope. Can. J. Anaesth. 2010;57:980–984. doi: 10.1007/s12630-010-9372-7. [DOI] [PubMed] [Google Scholar]
  • 20.Chen P.T., Ting C.K., Lee M.Y., Cheng H.W., Chan K.H., Chang W.K. A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope® with conventional blind placement. Anaesthesia. 2017;72:1097–1106. doi: 10.1111/anae.13984. [DOI] [PubMed] [Google Scholar]
  • 21.El-Tahan M.R., Khidr A.M., Gaarour I.S., Alshadwi S.A., Alghamdi T.A., Al’ghamdi A. A Comparison of 3 Videolaryngoscopes for Double-Lumen Tube Intubation in Humans by Users With Mixed Experience: A Randomized Controlled Study. J. Cardiothorac. Vasc. Anesth. 2018;32:277–286. doi: 10.1053/j.jvca.2017.08.009. [DOI] [PubMed] [Google Scholar]
  • 22.Hamp T., Stumpner T., Grubhofer G., Ruetzler K., Thell R., Hager H. Haemodynamic response at double lumen bronchial tube placement—Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial. Heart Lung Vessel. 2015;7:54–63. [PMC free article] [PubMed] [Google Scholar]
  • 23.Heir J.S., Guo S.-L., Purugganan R., Jackson T.A., Sekhon A.K., Mirza K., Lasala J., Feng L., Cata J.P. A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic Surgery. J. Cardiothorac. Vasc. Anesth. 2018;32:267–274. doi: 10.1053/j.jvca.2017.05.016. [DOI] [PubMed] [Google Scholar]
  • 24.Hsu H.T., Chou S.H., Wu P.J., Tseng K.Y., Kuo Y.W., Chou C.Y., Cheng K.I. Comparison of the GlideScope videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation. Anaesthesia. 2012;67:411–415. doi: 10.1111/j.1365-2044.2011.07049.x. [DOI] [PubMed] [Google Scholar]
  • 25.Hsu H.T., Chou S.H., Chen C.L., Tseng K.Y., Kuo Y.W., Chen M.K., Cheng K.I. Left endobronchial intubation with a double-lumen tube using direct laryngoscopy or the Trachway video stylet. Anaesthesia. 2013;68:851–855. doi: 10.1111/anae.12340. [DOI] [PubMed] [Google Scholar]
  • 26.Huang P., Zhou R., Lu Z., Hang Y., Wang S., Huang Z. GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: A randomized, controlled, prospective trial. BMC Anesthesiol. 2020;20:119. doi: 10.1186/s12871-020-01012-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Kido H., Komasawa N., Matsunami S., Kusaka Y., Minami T. Comparison of McGRATH MAC and Macintosh laryngoscopes for double-lumen endotracheal tube intubation by anesthesia residents: A prospective randomized clinical trial. J. Clin. Anesth. 2015;27:476–480. doi: 10.1016/j.jclinane.2015.05.011. [DOI] [PubMed] [Google Scholar]
  • 28.Levy-Faber D., Malyanker Y., Nir R.-R., Best L.A., Barak M. Comparison of VivaSight double-lumen tube with a conventional double-lumen tube in adult patients undergoing video-assisted thoracoscopic surgery. Anaesthesia. 2015;70:1259–1263. doi: 10.1111/anae.13177. [DOI] [PubMed] [Google Scholar]
  • 29.Lin W., Li H., Liu W., Cao L., Tan H., Zhong Z. A randomised trial comparing the CEL-100 videolaryngoscope(TM) with the Macintosh laryngoscope blade for insertion of double-lumen tubes. Anaesthesia. 2012;67:771–776. doi: 10.1111/j.1365-2044.2012.07137.x. [DOI] [PubMed] [Google Scholar]
  • 30.Liu H.-H., Dong F., Liu J.-Y., Wei J.-Q., Huang Y.-Q., Wang Y., Zhou T., Ma W.-H. The use of ETView endotracheal tube for surveillance after tube positioning in patients undergoing lobectomy, randomized trial. Medicine. 2018;97:e13170. doi: 10.1097/MD.0000000000013170. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Mathew A., Chandy J., Punnoose J., Gnanamuthu B.R., Jeyseelan L., Sahajanandan R. A randomized controlled study comparing CMAC video laryngoscope and Macintosh laryngoscope for insertion of double lumen tube in patients undergoing elective thoracotomy. J. Anaesthesiol. Clin. Pharmacol. 2021;37:266–271. doi: 10.4103/joacp.JOACP_79_20. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Onifade A., Lemon-Riggs D., Smith A., Pak T., Pruszynski J., Reznik S., Moon T.S. Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube-a randomized controlled trial. J. Thorac. Dis. 2020;12:6533–6541. doi: 10.21037/jtd-20-1595. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Risse J., Schubert A.-K., Wiesmann T., Huelshoff A., Stay D., Zentgraf M., Kirschbaum A., Wulf H., Feldmann C., Meggiolaro K.M. Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery—A randomised controlled clinical trial. BMC Anesthesiol. 2020;20:150. doi: 10.1186/s12871-020-01067-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Russell T., Slinger P., Roscoe A., McRae K., Van Rensburg A. A randomised controlled trial comparing the GlideScope() and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia. 2013;68:1253–1258. doi: 10.1111/anae.12322. [DOI] [PubMed] [Google Scholar]
  • 35.Schuepbach R., Grande B., Camen G., Schmidt A.R., Fischer H., Sessler D.I., Seifert B., Spahn D.R., Ruetzler K. Intubation with VivaSight or conventional left-sided double-lumen tubes: A randomized trial. Can. J. Anaesth. 2015;62:762–769. doi: 10.1007/s12630-015-0329-8. [DOI] [PubMed] [Google Scholar]
  • 36.Shah S.B., Bhargava A.K., Hariharan U., Mittal A.K., Goel N., Choudhary M. A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients. Indian J. Anaesth. 2016;60:312–318. doi: 10.4103/0019-5049.181591. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Wasem S., Lazarus M., Hain J., Festl J., Kranke P., Roewer N., Lange M., Smul T.M. Comparison of the Airtraq and the Macintosh laryngoscope for double-lumen tube intubation: A randomised clinical trial. Eur. J. Anaesthesiol. 2013;30:180–186. doi: 10.1097/EJA.0b013e32835fe574. [DOI] [PubMed] [Google Scholar]
  • 38.Xu T., Li M., Guo X.Y. Comparison of Shikani optical stylet and Macintosh laryngoscope for double-lumen endotracheal tube intubation. Beijing Da Xue Xue Bao Yi Xue Ban. 2015;47:853–857. [PubMed] [Google Scholar]
  • 39.Yang M., Kim J.A., Ahn H.J., Choi J.W., Kim D.K., Cho E.A. Double-lumen tube tracheal intubation using a rigid video-stylet: A randomized controlled comparison with the Macintosh laryngoscope. Br. J. Anaesth. 2013;111:990–995. doi: 10.1093/bja/aet281. [DOI] [PubMed] [Google Scholar]
  • 40.Yao W.L., Wan L., Xu H., Qian W., Wang X.R., Tian Y.K., Zhang C.H. A comparison of the McGrath® Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy. Anaesthesia. 2015;70:810–817. doi: 10.1111/anae.13040. [DOI] [PubMed] [Google Scholar]
  • 41.Yi J., Huang Y., Luo A. Comparison of GlideScope video-laryngoscope and Macintosh laryngoscope for double-lumen tube intubation. Chin. J. Anesthesiol. 2013;33:201–204. [Google Scholar]
  • 42.Yoo J.Y., Park S.Y., Kim J.Y., Kim M., Haam S.J., Kim D.H. Comparison of the McGrath videolaryngoscope and the Macintosh laryngoscope for double lumen endobronchial tube intubation in patients with manual in-line stabilization: A randomized controlled trial. Medicine. 2018;97:e0081. doi: 10.1097/MD.0000000000010081. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Liu T.T., Li L., Wan L., Zhang C.H., Yao W.L. Video laryngoscopy vs. Macintosh laryngoscopy for double-lumen tube intubation in thoracic surgery: A systematic review and meta-analysis. Anaesthesia. 2018;73:997–1007. doi: 10.1111/anae.14226. [DOI] [PubMed] [Google Scholar]
  • 44.Kim Y.S., Song J., Lim B.G., Lee I.O., Won Y.J. Different classes of videoscopes and direct laryngoscopes for double-lumen tube intubation in thoracic surgery: A systematic review and network meta-analysis. PLoS ONE. 2020;15:e0238060. doi: 10.1371/journal.pone.0238060. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Yao W.L., Zhang C.H. Macintosh laryngoscopy for double-lumen tube placement—A reply. Anaesthesia. 2015;70:1206–1208. doi: 10.1111/anae.13227. [DOI] [PubMed] [Google Scholar]
  • 46.El-Boghdadly K., Bailey C.R., Wiles M.D. Postoperative sore throat: A systematic review. Anaesthesia. 2016;71:706–717. doi: 10.1111/anae.13438. [DOI] [PubMed] [Google Scholar]
  • 47.Ham S.Y., Kim J., Oh Y.J., Lee B., Shin Y.S., Na S. Risk factors for peri-anaesthetic dental injury. Anaesthesia. 2016;71:1070–1076. doi: 10.1111/anae.13560. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

Not applicable.


Articles from Journal of Clinical Medicine are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES