Abstract
Objective
This study evaluated the influence of silicon dioxide (SiO2) nanoparticles on the flexural strength of heat-polymerized denture base materials.
Background
Nanoparticles have been incorporated into the denture base materials in different proportions to enhance the mechanical properties. Recently, the incorporation of SiO2 nanoparticles at low concentrations has shown promising outcomes.
Materials and Methods
Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) protocol, this study was designed with the following focused question: “Does the addition of SiO2 nanoparticles improve the flexural strength of heat-polymerized acrylic resins?” The inclusion criteria included in-vitro studies that assessed the flexural strength of SiO2 nanoparticle-reinforced heat-polymerized acrylic denture base resins tested according to American Dental Association specifications. The database search involved articles published from 2005 to 2020 on PubMed/MEDLINE, Web of Science, Google Scholar, and Scopus using the following keywords: SiO2, nanosilica, silica oxide, nanoparticles, denture base resin, acrylic resin, polymethyl methacrylate, PMMA, flexural strength, and mechanical properties.
Results
Among 167 studies, five papers fulfilled the inclusion criteria and were added for the data analysis and meta-analysis. Proportions of incorporated SiO2 nanoparticles ranged from 0.25% to 15% and the reported flexural strength values for the reinforced acrylic resin ranged from 41.25 MPa to 124.56 MPa. The meta-analysis revealed no significant effect on the flexural strength between the unmodified and the SiO2 nanoparticle-reinforced acrylic resin.
Conclusion
Therefore, No particular concentration of SiO2 nanoparticles could be recommended for heat-polymerized denture base reinforcement.
Keywords: PMMA, Denture base, Flexural strength, SiO2 nanoparticles, Systematic review, Meta-analysis
1. Introduction
Heat-polymerized acrylic resin is commonly used to fabricate definitive complete and partial removable dental prostheses (Polychronakis et al., n.d.). It has the features of a natural intra-oral appearance; biocompatibility; simple processing, finishing, and polishing techniques; and cost efficiency (Al-Thobity, 2020, Gad et al., 2019b). However, it has low flexural strength and toughness. A prosthesis fracture may ultimately occur under a functional load and repeated masticatory forces (Gad et al., 2020a, Gad et al., 2019c, Kanie et al., 2000).
Several materials and techniques have been employed to reinforce acrylic resin and improve its flexural properties (Ayaz et al., 2014, Gad et al., 2019a, Ozkir et al., 2018). Recently, the incorporation of nanoparticles into acrylic resin has been investigated (Al-Harbi et al., 2019, Bangera et al., 2020, Gad et al., 2019a) The nanoparticle dimensions range from 1 nm to 100 nm, resulting in a high surface area compared with the volume (Ashton, 2009). The reinforcement effect of nanoparticles for acrylic resin depends on the level of particle dispersion, particle size, and silanization (Du and Zheng, 2007). One of the widely used particles is silica (SiO2) nanoparticles. The addition of SiO2 nanoparticles to dental polymers and other dental composites has been revealed to be effective (Gad et al., 2017, Gad et al., 2020b, Hu et al., 2004, Okada et al., 2014). Gad et al. (2020b) found that adding SiO2 nanoparticles at low concentrations (0.25, 0.5 wt%) to the repaired resin substantially improved the flexural strength.
Numerous in vitro studies have assessed the mechanical properties of the SiO2 nanoparticle-reinforced acrylic resin (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Karci et al., 2019, Sodagar et al., 2013). The principal mode, which is pertinent to the loading of acrylic denture bases intraorally and in clinical failure, is the flexural strength test. It represents the highest level of stress within the material before the moment of yield (Chitchumnong et al., 1989). Conducting in vitro studies enables the standardization of the specimens’ preparation, allocation, and assessment, necessitating the comparison of the study variables and outcomes.
To the best of the authors’ knowledge and after reviewing the literature, no studies have yet reviewed the influence of SiO2 nanoparticles on the flexural strength of a heat-polymerized acrylic denture base material. Thus, this systematic review aimed to identify and analyze the effect of the incorporation of SiO2 nanoparticles on the flexural strength of heat-polymerized acrylic resin. The null hypothesis is that the incorporation of SiO2 nanoparticles into acrylic resin has no influence on flexural strength.
2. Materials and methods
2.1. Focused question and study protocol
The study protocol was carried out following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) model (Faggion, 2012). The focused question of this systematic review was formulated following the PICOS model to lead the literature search as follows: Population (P): denture base resin, heat-polymerized acrylic resin, polymethylmethacrylate (PMMA); Intervention (I): silica oxide nanoparticles; Comparison (C): the effect of silica oxide nanoparticles in different proportions compared with the conventional acrylic resin without SiO2 nanoparticles reinforcement; Outcomes (O): the flexural strength values of the SiO2 nanoparticle-reinforced acrylic resin denture base; Study design (S): in vitro laboratory-based studies.
After these elements were analyzed, the investigated PICOS question was as follows: “Does the addition of SiO2 nanoparticles improve the flexural strength of heat-polymerized acrylic resin?
2.2. Eligibility criteria
The inclusion criteria included in vitro studies that assessed the flexural strength of SiO2 nanoparticle-reinforced heat-polymerized acrylic denture base resins and compared it with the conventional acrylic resin (control group). Specimens with an adequate size were described clearly in the study methodology, and the specimens’ dimensions were designed and prepared in accordance with the American Dental Association (ADA) specifications/ISO (International Organization for Standardization) 20795.(“ISO 20795–1:2013. Dentistry – base polymer – part 1:denture base polymers. International Organization for Standardization; 2013,” n.d.) A three-point bending testing was applied using a standardized universal testing machine to assess the flexural strength property, and the results were statistically analyzed.
Studies out of the dentistry field, studies written in a language other than English, and review papers were excluded from this study. Studies that used acrylic resin other than the heat-polymerized acrylic resin, such as microwave polymerized, autopolymerized, and light polymerized, were omitted from this review. Articles that did not report flexural strength and SiO2 nanoparticle reinforcement were not eligible for review and analysis. Research that tested flexural strength using techniques other than the three-point bending strength test was also excluded from this study.
2.3. Search strategy
Electronic scientific databases (PubMed/MEDLINE, Web of Science, Google Scholar, and Scopus) were comprehensively searched to find relevant articles published between January 2005 and September 2020. This search was conducted using a combination of the following keywords: SiO2, nanosilica, silica oxide, nanoparticles, denture base resin, acrylic resin, polymethylmethacrylate, PMMA, flexural strength, and mechanical properties. To ensure that all eligible articles were included, the authors performed a manual search by checking the reference list of relevant review articles.
2.4. Study screening, selection, and management
The authors reviewed the titles to exclude papers that did not fulfill the inclusion criteria. The abstracts were examined for a qualification check whenever the titles were insufficiently illustrative for judgment. After omitting all duplicates, full text publications following the inclusion criteria were retrieved for scrutiny and data extraction. The obtained data from the included studies were tabulated using an electronic format (Microsoft Excel, V14.6.8, Redmond, WA, USA). The data were categorized as follows: authors’ names and year of publication; brand name of nanoparticles; nanoparticles size; silanization; Wt.%; sample size; acrylic resin type/ polymerization cycle; mixing protocol; specimens dimension; testing type/ standard; sample conditioning; mean (SD) of flexural strength (MPa); SEM analysis; and outcome (Appendix A Supplementary Material).
2.5. Risk of bias evaluation
The quality of the intended studies was evaluated and rated following the Consolidated Standards of Reporting Trials (CONSORT) guidelines (Faggion, 2012). After evaluating the studies individually, the parameters were presented as yes or no (Table 1). The Cochrane tool for risk of bias was adopted and modified to fulfill the study objective (Table 2).(Faggion, 2012, Higgins et al., 2011) The following criteria were employed to assess the potential risk of bias: calculation of sample size; selection bias, which is relevant to the sample allocation in the intended study, and concealment; blinding status of the operator; matching of the analysis methods with the ADA/ISO standards; and the reported outcomes. A score of zero was given if the study clearly described the previous criteria. If the data were insufficient or ambiguous, the score given was 1. Once the study undisclosed a particular setting, the score given was 2. Studies obtaining an overall score of 0–3 had a low risk of bias, 4–7 had a moderate risk, and 8–10 had a high risk. The authors performed the assessment separately and discussed it independently to sort out any ambiguity.
Table 1.
Characteristics of included studies based on modified CONSORT criteria.
| Article | Item grade |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2a | 2b | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | |
| Alnamel and Mudhaffer 2014 [32] | Yes | Yes | No | No | No | No | No | No | No | No | Yes | No | Yes | No | No |
| Salman et al 2017 [33] | Yes | Yes | No | No | Yes | No | No | No | No | No | Yes | Yes | Yes | No | No |
| Cevik and Yildirim-Bicer, 2018 [26] | Yes | Yes | Yes | Yes | Yes | No | Yes | No | No | No | Yes | Yes | Yes | No | No |
| Jiangkongkho et al. 2018 [24] | Yes | Yes | Yes | Yes | Yes | No | No | No | No | No | Yes | Yes | Yes | No | No |
| Karci et al 2019 [23] | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No | No | No | Yes | Yes | Yes | No | No |
(1) Structured summary of trial design, methods, results and conclusions, (2a) scientific background and explanation of rationale, (2b) specific objectives and/or hypothesis, (3) the intervention of each group, including how and when it was administered, with sufficient detail to enable replication, (4) completely defined, pre-specified primary and secondary measured of outcome, including how and when they were assessed, (5) how the sample size was determined, (6) method used to generate the random allocation sequence, (7) mechanism used to implement the random allocation sequence, (8) who generated the random allocation, (9) who was blinded after assignment to intervention, (10) statistical methods used to compare groups, (11) results for each group and estimated size of effect and its precision, (12) trial limitations, addressing sources of potential bias, imprecision, and, if relevant multiplicity of analysis, (13) sources of funding and other support, (14) where to full trial protocol can be accessed.16
Table 2.
Risk of bias tool (adapted and modified from Cochrane risk of bias tool).
| Article | Allocation concealment |
Sample size |
Blinding | Assessment methods |
Selective outcome reporting |
Risk of bias |
|---|---|---|---|---|---|---|
| Alnamel and Mudhaffer, 2014 [32] | 1 | 2 | 2 | 2 | 1 | High |
| Salman et al., 2017 [33] | 1 | 2 | 2 | 0 | 0 | Moderate |
| Cevik and Yildirim-Bicer, 2018 [26] | 1 | 2 | 2 | 0 | 0 | Moderate |
| Jiangkongkho et al., 2018 [24] | 1 | 2 | 2 | 0 | 0 | Moderate |
| Karci et al., 2019 [23] | 1 | 0 | 2 | 0 | 0 | Low |
2.6. Statistical analysis
The meta-analysis was conducted based on the study objective to analyze the flexural strength property of the included studies. A random effect model was applied using Review Manager (RevMan version 5.4; The Cochrane Collaboration, 2020). The SiO2 nanoparticle groups subjected to the meta-analysis were 1%, 3%, 5%, and 7%, and the other groups (0.25%, 0.50%, 10%, and 15%) were not included because of inadequate outcomes for comparison. A 95% confidence interval (Z) was used to create the forest plot. The inconsistency I2 test was applied to calculate the heterogeneity between the study results. When the I2 value was greater than 50%, heterogeneity was counted substantial. The funnel plot could not be applied because of the limited number of studies included in the meta-analysis for each nanoparticle proportion (n < 10).
3. Results
3.1. Study selection
The primarily search throughout the four scientific databases yielded 167 scientific publications (Fig. 1). Among them, 23 were duplicates, 81 had irrelevant titles, and 5 were not published in English and thus were excluded. A total of 58 scientific papers were extensively scrutinized for abstract review, and 14 were found to be related to this review question. After scrutinizing these articles, five fulfilled the inclusion criteria and were added in the data analysis, while the remaining nine were excluded because they incorporated with micro-silica, employed acrylic resin other than heat-polymerized, or did not follow the ADA/ISO standards. The methodology, results, and outcomes of these studies are summarized in (Appendix A Supplementary Material).
Fig.1.
Flow chart of the search strategy and study selection following PRISMA protocol.
3.2. Risk of bias
The risk of bias of the intended studies is shown in Table 2. Among the five studies (Alnamel and Mudhaffer, 2014, Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Karci et al., 2019, Salman et al., 2017), one (Alnamel and Mudhaffer, 2014) had a high risk, three (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Salman et al., 2017) had a moderate risk, and one (Karci et al., 2019) had a low risk of bias. The high risk rating was mainly due to the failure to report the sample size calculation, assessment methods, and blinding of investigators. The moderate risk assessment referred to the failure to blind the investigators and to state the method of sample size calculation.
3.3. Qualitative data analysis
All studies included in this review were in vitro laboratory based and used SiO2 nanoparticles in different proportions to reinforce heat-polymerized acrylic denture base resins. The applied sample size was set to 10 specimens for three studies (Alnamel and Mudhaffer, 2014, Karci et al., 2019, Salman et al., 2017) and eight specimens for two studies (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018) for the control and the test groups.
The incorporated weight proportions of SiO2 nanoparticles varied among the studies and ranged from 0.25% to 15% (Jiangkongkho et al., 2018). The incorporated SiO2 nanoparticles were prepared in different sizes, with the smallest at 15 nm (Karci et al., 2019) and the largest at < 100 nm (Alnamel and Mudhaffer, 2014). Salman et al. (Salman et al., 2017) investigated two types of SiO2 nanoparticles: 70-nm crystalline nanosilica sand (NSS) and 50-nm amorphous nanosilica (NS). Three studies (Alnamel and Mudhaffer, 2014, Karci et al., 2019, Salman et al., 2017) did not state whether the nanoparticles were silanized, and two studies (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018) performed the silanization procedure of the SiO2 nanoparticles before their incorporation into the resin. Four studies added the SiO2 nanoparticles into the methylmethacrylate monomer (Alnamel and Mudhaffer, 2014, Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Salman et al., 2017), and one study added it to the PMMA powder before mixing (Karci et al., 2019).
All studies performed the water bath method for heat polymerization. Three studies (Alnamel and Mudhaffer, 2014, Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018) conducted the short cycle, one study (Karci et al., 2019) implemented the long cycle, and one study (Salman et al., 2017) did not describe the heat polymerization technique in detail. Three studies (Alnamel and Mudhaffer, 2014, Jiangkongkho et al., 2018, Salman et al., 2017) conditioned the specimens through water immersion before testing, and two studies did not report it (Cevik and Yildirim-Bicer, 2018, Karci et al., 2019). The results of the studies were diverse regarding the mean value of the flexural strength for both the unmodified and reinforced groups. The lowest value in the control groups was 34.5 MPa (Salman et al., 2017), whereas the highest value was 188.3 MPa (Cevik and Yildirim-Bicer, 2018). Conversely, the highest flexural strength mean value in the reinforced groups was 124.56 MPa (Alnamel and Mudhaffer, 2014) after a 5% SiO2 nanoparticle reinforcement, whereas the lowest value was 41.25 MPa after the incorporation of 3% SiO2 nanoparticles (Salman et al., 2017). Cevik and Yildirim-Bicer, 2018, Salman et al., 2017 (NS) showed a direct relation in which the flexural strength increased once the percentage of the nanoparticles increased, whereas the results of Karci et al. (2019) exhibited a decrease in the flexural strength upon an increase in the nanoparticle percentage. The other studies (Alnamel and Mudhaffer, 2014, Jiangkongkho et al., 2018, Salman et al., 2017) showed a limited increase in flexural strength through the addition of low concentrations of nanoparticles and a decrease in flexural strength when the nanoparticle addition reached the highest tested concentrations.
Four studies (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Karci et al., 2019, Salman et al., 2017) performed SEM analysis to assess the surface characteristics of the control and reinforced specimens. Cevik and Yildirim-Bicer (2018) reported that the addition of 5% nanoparticles did not accompany an eminent cluster of the nanoparticles referred to in the SCA application. Jiangkongkho et al. (2018) found that at high magnification, the nanoparticles acted as a hindrance to prevent or deviate crack propagation. Karci et al. (2019) found that the nanoparticles at a high concentration became agglomerated, and this could explain the lower flexural strength at a high concentration (5%). Salman et al. (Salman et al., 2017) reported a homogenous distribution of nanoparticles that filled the pores in a polymer matrix, formulating a dense structure of PMMA/NS nanocomposites.
3.4. Meta-analysis
Four meta-analyses, including the five studies, were carried out by generating forest plots. Salman et al. (2017) analyzed the two types of nanosilica (NS and NSS) separately. The flexural strength mean values and SD were employed based on the respective SiO2 nanoparticle proportions.
Fig. 2 shows the forest plot for the addition of 1% SiO2 nanoparticles in three studies (Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Karci et al., 2019). The addition of 1% SiO2 nanoparticles had no significant effect on the flexural strength compared with the control group. The mean difference (MD) of this analysis was −19.52, the 95% confidence interval (CI) was − 59.31–20.30, and the total number of specimens was 46. All included studies showed a high level of heterogeneity (I2 inconsistency test was 99%).
Fig.2.
Forest plot for 1% SiO2 reinforcement.
The forest plot in Fig. 3 presents the effect of adding 3% SiO2 nanoparticles in three studies (Alnamel and Mudhaffer, 2014, Karci et al., 2019, Salman et al., 2017), with one study having two types of nanosilica. This nanoparticle proportion did not significantly improve the flexural strength compared with the control group. The MD was 4.82, the 95% CI was − 5.92–15.56, and the total number of specimens was 74. A substantial level of heterogeneity was observed in this analysis (I2 inconsistency test was 93%).
Fig.3.
Forest plot for 3% SiO2 reinforcement.
The meta-analysis of the addition of 5% SiO2 nanoparticles is presented in Fig. 4. The forest plot showed no remarkable increase in flexural strength with the addition of 5% nanoparticles in the unmodified control group. A substantial level of heterogeneity of the included studies was observed (I2 inconsistency test was 98%). The number of studies (Alnamel and Mudhaffer, 2014, Cevik and Yildirim-Bicer, 2018, Jiangkongkho et al., 2018, Karci et al., 2019, Salman et al., 2017) was 5 (with one of them investigating two types of nanosilica), the MD was − 7.02, the 95% CI was − 20.64–6.59, and the total number of specimens was 106.
Fig.4.
Forest plot for 5% SiO2 reinforcement.
Fig. 5 shows the meta-analysis of the effect of adding 7% SiO2 nanoparticles to the acrylic resin in two studies, with one study assessing two types of nanosilica (Alnamel and Mudhaffer, 2014, Salman et al., 2017). A high degree of heterogeneity was observed (I2 inconsistency test was 95%). The addition of 7% SiO2 nanoparticles did not show a substantial enhancement in flexural strength compared with the control group. The MD was 9.60, the 95% CI was − 6.61–25.81, and the total number of specimens was 60.
Fig.5.
Forest plot for 7% SiO2 reinforcement.
4. Discussion
This systematic review was conducted to investigate the influence of SiO2 nanoparticles on the flexural strength of a heat-polymerized acrylic denture base resin. According to the meta-analysis conducted to analyze the effect of the weight proportions (1%, 3%, 5%, and 7%) of four nanoparticles, no significant enhancement was observed in the flexural strength value in the unmodified acrylic resin (control group), although two of these proportions (3% and 7%) had a positive effect based on the effect estimate by increasing the flexural strength values by 4.82 MPa and 9.60 MPa, respectively. Thus, the null hypothesis of this study was accepted. The meta-analysis showed substantial heterogeneity among the included studies based on the I2 inconsistency test ranging from 93% to 99%. This high heterogeneity could be due to variations in the sample size, testing method, size of SiO2 nanoparticles, concentration of SiO2 nanoparticles, silanization process, resin type, resin composition, polymerization cycle of the resin, and the conditioning of the specimens.
The incorporation of SiO2 nanoparticles to the acrylic resin has been suggested to promote the mechanical properties.(Balos et al., 2014, Hu et al., 2004, Lazzara and Milioto, 2010) Balos et al. (Balos et al., 2014) reported that microhardness and fracture toughness were improved at low concentrations. However, increasing the content of SiO2 nanoparticles resulted in the reduction of mechanical properties. Some studies included in this review showed similar effects of flexural strength increasing at low concentrations of SiO2 nanoparticles and decreasing at high levels (Alnamel and Mudhaffer, 2014, Jiangkongkho et al., 2018, Salman et al., 2017). This behavior could be attributed to the fact that the addition of nanoparticles at low concentrations could lead to the distribution of nanoparticles homogenously within the polymer matrix spaces and the creation of an interfacial bond between the nanoparticles and the polymer matrix, which could arrest or deviate the crack and improve flexural strength (Cevik and Yildirim-Bicer, 2018, Hafizah et al., 2013, Karci et al., 2019, Sivaraman et al., 2006).
One of the methods that have been investigated to reduce surface energy and inhibit nanoparticle clustering is the silanization of nanoparticles (Chandra et al., 2008). This method is applied by using an SCA as a dispersing agent, such as γ-methacrylo-propyl-trimethoxysilane, to treat the SiO2 nanoparticles (Kanie et al., 2004). Owing to the functional groups in its chemical structure, the coupling agent can form a strong bond between the SiO2 nanoparticles and the polymer matrix and positively enhance the mechanical properties (Katsikis et al., 2007).
Based on the current ISO protocol, specimens should be immersed in water for 50 ± 2 h at 37 °C prior to flexural strength testing.(“ISO 20795–1:2013. Dentistry – base polymer – part 1:denture base polymers International Organization for Standardization; 2013, n.d.). Two studies (Alnamel and Mudhaffer, 2014, Jiangkongkho et al., 2018) followed the ISO standards, two studies (Cevik and Yildirim-Bicer, 2018, Karci et al., 2019) failed to state the specimens’ conditioning procedure, and one study exceeded the ISO standards (Salman et al., 2017). Salman et al. (2017) left the unreinforced and reinforced specimens in water for 14 days at room temperature prior to testing. The flexural strength value for the control group was 34.5 MPa and that for the reinforced group was 41.25–60 MPa. This reduction in flexural strength can be attributed to the long immersion of the specimens in water, the molecules of which diffuse into the polymer matrix and fill the voids created from leaching out of the water-soluble particles in acrylic resin (Arima et al., 1995, Gad et al., 2020a, Vallittu et al., 1995).
In the studies involved in this review, a considerable variation was found in the polymerization cycle used for the specimens. Moreover Karci et al. (2019), polymerized the specimens using a long curing cycle by keeping the specimens in a water bath at 74 ± 1 °C for 8 h and then boiling for 2 h, whereas other studies used a short curing cycle at different extents. This diversity in curing cycles could have affected the flexural strength of acrylic resin. Seo et al. (2007) found that the polymerization of acrylic resin at 73 °C for 90 min and then at 100 °C as a boiling temperature for 30 min (short cycle) substantially increased the flexural strength compared with the polymerization at 71 °C for 9 h. This effect can be justified by the degree of residual monomer conversion in which the residual monomer content is most likely higher in the long cycle than in the short cycle, consequently affecting the flexural strength of acrylic resin (Azzarri et al., 2003, Gungor et al., 2017, Urban et al., 2007).
This review has some limitations, such as the limited number of studies assessing the effect of SiO2 nanoparticle addition on the flexural strength of heat-polymerized acrylic resin. As the analysis of the review was limited to heat-polymerized acrylic resin, the results cannot be adapted to other types of acrylic resins, such as autopolymerized, light polymerized, and microwave and autoclave polymerization. Moreover, the mechanical properties other than flexural strength were not analyzed.
5. Conclusions
The values of the flexural strength property of SiO2 nanoparticle-reinforced heat-polymerized acrylic resin were diverse among the analyzed studies depending on the concentration, dimension, geometry, and silanization of nanoparticles. The other factors affecting the results were the specimens’ preparation, conditioning of the specimens, polymerization cycle, and testing protocol. The meta-analysis revealed no significant effect on flexural strength between the unmodified and the SiO2 nanoparticle-reinforced acrylic resin. Thus, no particular concentration of SiO2 nanoparticles could be recommended for acrylic resin reinforcement.
Footnotes
Peer review under responsibility of King Saud University.
Supplementary data to this article can be found online at https://doi.org/10.1016/j.sdentj.2021.08.008.
Contributor Information
Ahmad M. Al-Thobity, Email: aalthobity@iau.edu.sa.
Mohammed M. Gad, Email: mmjad@iau.edu.sa.
Appendix A. Supplementary material
The following are the Supplementary data to this article:
References
- Al-Harbi F.A., Abdel-Halim M.S., Gad M.M., Fouda S.M., Baba N.Z., AlRumaih H.S., Akhtar S. Effect of Nanodiamond Addition on Flexural Strength, Impact Strength, and Surface Roughness of PMMA Denture Base. J. Prosthodont. 2019;28(1):e417–e425. doi: 10.1111/jopr.12969. [DOI] [PubMed] [Google Scholar]
- Al-Thobity A.M. The Impact of Polymerization Technique and Glass-Fiber Reinforcement on the Flexural Properties of Denture Base Resin Material. Eur. J. Dent. 2020;14(01):092–099. doi: 10.1055/s-0040-1701922. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Alnamel H.A., Mudhaffer M. The Effect of Silicon Di Oxide Nano - Fillers Reinforcement on Some Properties of Heat Cure Polymethyl Methacrylate Denture Base Material. J. Baghdad Coll. Dent. 2014;26:32–36. doi: 10.12816/0015142. [DOI] [Google Scholar]
- Arima T., Murata H., Hamada T. Properties of highly cross-linked autopolymerizing reline acrylic resins. J. Prosthet. Dent. 1995;73(1):55–59. doi: 10.1016/S0022-3913(05)80273-2. [DOI] [PubMed] [Google Scholar]
- Ashton, H., 2009. The Incorporation of Nanomaterials into Polymer Media, in: Polymer Nanocomposites Handbook. CRC Press. https://doi.org/10.1201/9781420009804-c3.
- Ayaz E.A., Durkan R., Koroglu A., Bagis B. Comparative effect of different polymerization techniques on residual monomer and hardness properties of PMMA-based denture resins. J. Appl. Biomater. Funct. Mater. 2014;12(3):228–233. doi: 10.5301/jabfm.5000199. [DOI] [PubMed] [Google Scholar]
- Azzarri M.J., Cortizo M.S., Alessandrini J.L. Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised. J. Dent. 2003;31(7):463–468. doi: 10.1016/S0300-5712(03)00090-3. [DOI] [PubMed] [Google Scholar]
- Balos S., Pilic B., Markovic D., Pavlicevic J., Luzanin O. Poly(methyl-methacrylate) nanocomposites with low silica addition. J. Prosthet. Dent. 2014;111(4):327–334. doi: 10.1016/j.prosdent.2013.06.021. [DOI] [PubMed] [Google Scholar]
- Bangera M.K., Kotian R., Ravishankar N. Effect of titanium dioxide nanoparticle reinforcement on flexural strength of denture base resin: A systematic review and meta-analysis. Jpn. Dent. Sci. Rev. 2020;56:68–76. doi: 10.1016/j.jdsr.2020.01.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cevik P., Yildirim-Bicer A.Z. The Effect of Silica and Prepolymer Nanoparticles on the Mechanical Properties of Denture Base Acrylic Resin. J. Prosthodont. 2018;27(8):763–770. doi: 10.1111/jopr.2018.27.issue-810.1111/jopr.12573. [DOI] [PubMed] [Google Scholar]
- Chandra A., Turng L.-S., Gopalan P., Rowell R.M., Gong S. Study of utilizing thin polymer surface coating on the nanoparticles for melt compounding of polycarbonate/alumina nanocomposites and their optical properties. Compos. Sci. Technol. 2008;68(3-4):768–776. doi: 10.1016/j.compscitech.2007.08.027. [DOI] [Google Scholar]
- Chitchumnong P., Brooks S.C., Stafford G.D. Comparison of three- and four-point flexural strength testing of denture-base polymers. Dent. Mater. 1989;5(1):2–5. doi: 10.1016/0109-5641(89)90082-1. [DOI] [PubMed] [Google Scholar]
- Du M., Zheng Y. Modification of silica nanoparticles and their application in UDMA dental polymeric composites. Polym. Compos. 2007;28(2):198–207. doi: 10.1002/(ISSN)1548-056910.1002/pc.v28:210.1002/pc.20377. [DOI] [Google Scholar]
- Faggion C.M. Guidelines for Reporting Pre-clinical In Vitro Studies on Dental Materials. J. Evid. Based Dent. Pract. 2012;12:182–189. doi: 10.1016/j.jebdp.2012.10.001. [DOI] [PubMed] [Google Scholar]
- Gad M., Fouda S., Al-Harbi F., Näpänkangas R., Raustia A. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition. Int. J. Nanomedicine. 2017;12:3801–3812. doi: 10.2147/IJN.S130722. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gad M., Rahoma A., Abualsaud R., Al-Thobity A., Akhtar S., Siddiqui I., Al-Harbi F. Influence of artificial aging and ZrO2 nanoparticle-reinforced repair resin on the denture repair strength. J. Clin. Exp. Dent. 2020:e354–e362. doi: 10.4317/jced.56610. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gad M.M., Al-Thobity A.M., Rahoma A., Abualsaud R., Al-Harbi F.A., Akhtar S. Reinforcement of PMMA Denture Base Material with a Mixture of ZrO 2 Nanoparticles and Glass Fibers. Int. J. Dent. 2019;2019:1–11. doi: 10.1155/2019/2489393. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gad M.M., Fouda S.M., ArRejaie A.S., Al-Thobity A.M. Comparative Effect of Different Polymerization Techniques on the Flexural and Surface Properties of Acrylic Denture Bases. J. Prosthodont. 2019;28(4):458–465. doi: 10.1111/jopr.2019.28.issue-410.1111/jopr.12605. [DOI] [PubMed] [Google Scholar]
- Gad M.M., Rahoma A., Abualsaud R., Al‐Thobity A.M., Fouda S.M. Effect of Repair Gap Width on the Strength of Denture Repair: An In Vitro Comparative Study. J. Prosthodont. 2019;28(6):684–691. doi: 10.1111/jopr.2019.28.issue-610.1111/jopr.13091. [DOI] [PubMed] [Google Scholar]
- Gad M.M.A., Abualsaud R., Al-Thobity A.M., Almaskin D.F., AlZaher Z.A., Abushowmi T.H., Qaw M.S., Akhtar S., Al-Harbi F.A. Effect of SiO2 Nanoparticles Addition on the Flexural Strength of Repaired Acrylic Denture Base. Eur. J. Dent. 2020;14(01):019–023. doi: 10.1055/s-0039-1701076. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gungor H., Gundogdu M., Alkurt M., Duymus Z.Y. Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials. Dent. Mater. J. 2017;36:168–173. doi: 10.4012/dmj.2016-023. [DOI] [PubMed] [Google Scholar]
- Hafizah N.N., Mamat M.H., Abidin M.H., Said C.M.S., Rusop M. Bonding and Mechanical Properties of PMMA/TiO2 Nanocomposites. Adv. Mater. Res. 2013;832:700–705. doi: 10.4028/www.scientific.net/AMR.832.700. [DOI] [Google Scholar]
- Higgins, J.P.T., Altman, D.G., Gotzsche, P.C., Juni, P., Moher, D., Oxman, A.D., Savovic, J., Schulz, K.F., Weeks, L., Sterne, J.A.C., 2011. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 343, d5928–d5928. https://doi.org/10.1136/bmj.d5928. [DOI] [PMC free article] [PubMed]
- Hu Y.-H., Chen C.-Y., Wang C.-C. Viscoelastic properties and thermal degradation kinetics of silica/PMMA nanocomposites. Polym. Degrad. Stab. 2004;84(3):545–553. doi: 10.1016/j.polymdegradstab.2004.02.001. [DOI] [Google Scholar]
- ISO 20795-1:2013. Dentistry – base polymer – part 1:denture base polymers. International Organization for Standardization; 2013, n.d.
- Jiangkongkho P., Arksornnukit M., Takahashi H. The synthesis, modification, and application of nanosilica in polymethyl methacrylate denture base. Dent. Mater. J. 2018;37(4):582–591. doi: 10.4012/dmj.2017-142. [DOI] [PubMed] [Google Scholar]
- Kanie T., Arikawa H., Fujii K., Inoue K. Physical and mechanical properties of PMMA resins containing γ-methacryloxypropyltrimethoxysilane. J. Oral Rehabil. 2004;31:166–171. doi: 10.1111/j.1365-2842.2004.01043.x. [DOI] [PubMed] [Google Scholar]
- Kanie T., Fujii K., Arikawa H., Inoue K. Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers. Dent. Mater. 2000;16(2):150–158. doi: 10.1016/S0109-5641(99)00097-4. [DOI] [PubMed] [Google Scholar]
- Karci M., Demir N., Yazman S. Evaluation of Flexural Strength of Different Denture Base Materials Reinforced with Different Nanoparticles. J. Prosthodont. 2019;28(5):572–579. doi: 10.1111/jopr.2019.28.issue-510.1111/jopr.12974. [DOI] [PubMed] [Google Scholar]
- Katsikis N., Zahradnik F., Helmschrott A., Münstedt H., Vital A. Thermal stability of poly(methyl methacrylate)/silica nano- and microcomposites as investigated by dynamic-mechanical experiments. Polym. Degrad. Stab. 2007;92(11):1966–1976. doi: 10.1016/j.polymdegradstab.2007.08.009. [DOI] [Google Scholar]
- Lazzara G., Milioto S. Dispersions of nanosilica in biocompatible copolymers. Polym. Degrad. Stab. 2010;95(4):610–617. doi: 10.1016/j.polymdegradstab.2009.12.007. [DOI] [Google Scholar]
- Okada K., Kameya T., Ishino H., Hayakawa T. A novel technique for preparing dental CAD/CAM composite resin blocks using the filler press and monomer infiltration method. Dent. Mater. J. 2014;33(2):203–209. doi: 10.4012/dmj.2013-329. [DOI] [PubMed] [Google Scholar]
- Ozkir S.E., Yilmaz B., Unal S.M., Culhaoglu A., Kurkcuoglu I. Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate. Eur. J. Dent. 2018;12(01):116–119. doi: 10.4103/ejd.ejd_199_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Polychronakis, N., Yannikakis, S., Zissis, A., n.d. A clinical 5-year longitudinal study on the dimensional changes of complete maxillary dentures. Int. J. Prosthodont. 16, 78–81. [PubMed]
- Salman A.D., Jani G.H., Fatalla A. Comparative Study of the Effect of Incorporating SiO2 Nano-Particles on Properties of Poly methyl Methacrylate Denture Bases. Biomed. Pharmacol. J. 2017;10:1525–1535. doi: 10.13005/bpj/1262. [DOI] [Google Scholar]
- Seo R.S., Vergani C.E., Giampaolo E.T., Pavarina A.C., Machado A.L. Effect of a post-polymerization treatments on the flexural strength and Vickers hardness of reline and acrylic denture base resins. J. Appl. Oral Sci. 2007;15(6):506–511. doi: 10.1590/S1678-77572007000600010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sivaraman P., Chandrasekhar L., Mishra V.S., Chakraborty B.C., Varghese T.O. Fracture toughness of thermoplastic co-poly (ether ester) elastomer—Acrylonitrile butadiene styrene terpolymer blends. Polym. Test. 2006;25(4):562–567. doi: 10.1016/j.polymertesting.2006.03.007. [DOI] [Google Scholar]
- Sodagar A., Bahador A., Khalil S., Saffar Shahroudi A., Zaman Kassaee M. The effect of TiO2 and SiO2 nanoparticles on flexural strength of poly (methyl methacrylate) acrylic resins. J. Prosthodont. Res. 2013;57(1):15–19. doi: 10.1016/j.jpor.2012.05.001. [DOI] [PubMed] [Google Scholar]
- Urban V.M., Machado A.L., Oliveira R.V., Vergani C.E., Pavarina A.C., Cass Q.B. Residual Monomer of Reline Acrylic Resins. Effect of Water-Bath and Microwave Post-Polymerization Treatments. Dent. Mater. 2007;23(3):363–368. doi: 10.1016/j.dental.2006.01.021. [DOI] [PubMed] [Google Scholar]
- Vallittu P.K., Miettinen V., Alakuijala P. Residual monomer content and its release into water from denture base materials. Dent. Mater. 1995;11(5-6):338–342. doi: 10.1016/0109-5641(95)80031-X. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.