Abstract
Critical care echocardiography has become fundamental in diagnosis, management, and monitoring of patients in shock. Transesophageal echocardiography has gained importance, particularly in critically ill patients under mechanical ventilation. We describe echocardiographic findings concerning a patient admitted with confusion, pulmonary edema, hypotension, and systolic murmur at apex.
Keywords: circulatory shock, critical care echocardiography, endocarditis, hemodynamic monitoring, transesophageal echocardiography
Consensus on circulatory shock and hemodynamic monitoring suggests that echocardiography is the preferred modality for initial evaluation. Cardiac causes of acute pulmonary edema with normal LVEF include significant valvular pathology.

1. INTRODUCTION
Critical care echocardiography has become fundamental in diagnosis, management, and monitoring of patients in shock. Consensus on circulatory shock and hemodynamic monitoring suggests that echocardiography is the preferred modality for initial evaluation. 1 Transesophageal echocardiography (TEE) has gained importance, particularly in critically ill patients under mechanical ventilation. 2
2. CASE PRESENTATION
We present a case of a 65‐year‐old female patient admitted with confusion, pulmonary edema, hypotension, and systolic murmur at apex. Blood tests revealed elevated CRP (56 mg/L) with hyperleukocytosis (16,400/µl), renal failure (MDRD: 23/ml/min/1.73 m²), hepatitis (ALT: 1017 IU/L), elevated NT‐proBNP (>35,000 pg/ml), and hyperlactatemia (4.0 mmol/L). Transthoracic echocardiography demonstrated a severe mitral regurgitation. After stabilization, TEE was performed for its incremental value in terms of diagnosis and hemodynamic monitoring.
3. RESULTS
TEE illustrated the mechanism of the multiple‐valve disease, which was not clearly defined by transthoracic examination. The mitral valve disease was characterized by a perforation of the anterior mitral valve leaflet (AMVL) with a 9‐mm defect responsible for a severe and eccentric mitral regurgitation, as documented by the presence of a convergence flow over the hole of the mitral valve (Figure 1A). 3D imaging showed a well‐circumscribed hole in the A2 segment (Figure 1B; Video S1; Supplementary Material). TEE aortic valve assessment revealed a moderate aortic regurgitation with a bulky vegetation (12 × 3 mm) attached to the right cusp and prolapsing toward the left ventricle (Figure 1C). Hemodynamic assessment demonstrated a normal LVEF with elevated LV filling pressure (early mitral inflow velocity (E) to early diastolic mitral annular tissue velocity (E′) ratio: E/E′ > 15), pulmonary hypertension (systolic pulmonary artery pressure: 50 mm Hg + central venous pressure), and no respiratory variation in superior vena cava diameter. After diagnosis, the treatment consisted of broad‐spectrum antibiotics infusion after repeated blood cultures, diuretic therapy to achieve negative fluid balance and surgical management with double valve replacement. Unfortunately, the patient fell into refractory septic shock with multiple organ failure and deceased 48 h later.
FIGURE 1.

Panel A. 9‐mm defect of the AMVL due to perforation seen by 2D TEE from the apical 4‐chamber view. Panel B. Perforated AMVL seen by 3D TEE in the “surgeon's view.” Panel C. Mobile vegetation attached to the right aortic cusp and prolapsing toward the left ventricle with a moderate aortic regurgitation
4. CONCLUSION
Critical care echocardiography is a key in characterizing shock states. Cardiac causes of acute pulmonary edema with normal LVEF and elevated left atrial pressure include significant valvular pathology. We illustrated by 3D TEE technology a bi‐valvular infective endocarditis complicated with mitral leaflet perforation and moderate aortic regurgitation. This case report demonstrates that 3D ultrasound imaging provides additional information when more detailed analysis of cardiac structures is required.
CONFLICT OF INTEREST
The authors have no conflicts of interest to declare.
AUTHOR CONTRIBUTIONS
All authors have made substantial contribution to the preparation of this manuscript. JH acquired the images, interpreted the data, and drafted the manuscript. FF performed literature search. PFL made critical revision and approved the final manuscript.
CONSENT
Written informed consent was obtained from the patient to publish this report for educational/research purposes in accordance with the journal's patient consent policy.
Supporting information
Video S1
Supplementary Material
ACKNOWLEDGEMENTS
We gratefully acknowledge the work of members of our hospital who facilitated this work.
Higny J, Forêt F, Laterre P‐F. Three‐dimensional critical care transesophageal echocardiography: A bedside tool in the diagnosis and management of shock. Clin Case Rep. 2021;9:e05164. doi: 10.1002/ccr3.5164
DATA AVAILABILITY STATEMENT
The datasets generated during the current report are available from the corresponding author on reasonable request.
REFERENCES
- 1. Cecconi M, De Backer D, Antonelli M, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795‐1815. doi: 10.1007/s00134-014-3525-z [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Slama MA, Novara A, Van de Putte P, et al. Diagnostic and therapeutic implications of transesophageal echocardiography in medical ICU patients with unexplained shock, hypoxemia, or suspected endocarditis. Intensive Care Med. 1996;22(9):916‐922. doi: 10.1007/BF02044116 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Video S1
Supplementary Material
Data Availability Statement
The datasets generated during the current report are available from the corresponding author on reasonable request.