Abstract
Background:
Our aim was to compare the outcome between suture button (SB) stabilization and syndesmotic screw fixation (SF) in patients with acute syndesmotic diastasis.
Methods:
A systematic literature search up to June 30, 2021, was performed to identify randomized controlled trials (RCTs) comparing outcomes of SB with SF techniques in patients with acute syndesmotic diastasis. We calculated mean differences for continuous outcomes, using the Hartung-Knapp-Sidik-Jonkman method, and odds ratio for dichotomous outcomes, using the Mantel-Haenszel method.
Results:
Eight RCTs involving 569 patients met the inclusion criteria, 1 RCT with level I evidence, and 7 RCTs with level II evidence. The meta-analysis showed that the SB technique had a higher AOFAS score <6 months and 12 months postoperatively (MD = 4.74, 95% CI 1.68-7.80, P = .01; and MD = 5.42, 95% CI 1.50-9.33, P = .02) and reduced the risk of implant irritation (OR = 0.31, 95% CI 0.11-0.89, P = .03), implant failure (OR = 0.06, 95% CI 0.02-0.23, P < .01), and reoperation (OR = 0.43, 95% CI 0.22-0.83, P = .01). The 2 approaches did not differ in further functional outcomes or postoperative complications.
Conclusion:
Because functional outcomes showed no relevant difference between both SB and SF, the advantage of SB appears to be in the lower risk for postoperative complications. The SB technique led to fewer cases of implant irritation, implant failure, and reoperation compared with SF.
Level of Evidence:
Level I, meta-analysis of RCTs.
Keywords: screw, suture button, ankle, diastasis, syndesmosis
Introduction
Ankle injuries are the most common lower extremity injuries. 9 They represent a sequence of bone and/or ligament lesions 23 that lead to acute syndesmotic diastasis (acute syndesmotic instability) in about a quarter of cases.23,33 Adequate surgical treatment of the acute syndesmotic diastasis is of great importance, because otherwise there is a high risk of very limited function of the ankle joint.8,33,43 Being the conventional surgical treatment, syndesmotic screw fixation (SF) is known to be associated with complications such as implant irritation, loosening or breakage, and limited range of motion (ROM).13,41 For these reasons, there have been attempts of alternative methods of surgical treatment such as a dynamic stabilization. The usage of suture buttons (SBs) seems to be a very promising surgical technique for dynamic stabilization of the acute syndesmotic diastasis.30,39 Although some meta-analyses on this topic are available, some do not provide reliable results and others followed poor statistical methods.4,10-12,14,26,29,36,45-47 The specialist literature still has room for high-quality studies on this subject. We formulated the following PICO (population, intervention, control, and outcomes) question: In human participants in acute syndesmotic diastasis injury, is the SB technique superior compared with the SS technique in functional outcome and complications? Furthermore, we examined the consistency of our results with similar meta-analyses.
Methods
Literature Search and Study Selection
We followed the PRISMA-P guidelines. The review protocol was registered with PROSPERO on July 25, 2021, and finally approved on August 27, 2021 (CRD42021269965) at http://www.crd.york.ac.uk/PROSPERO/. We searched PubMed without restrictions to publication date or language up to June 30, 2021, for relevant randomized controlled trials (RCTs), building a BOOLEAN search strategy: [(syndesmotic screw OR screw fixation) AND (ankle fracture OR syndesmosis)]. Furthermore, we searched Google Scholar for relevant RCTs and checked citations of screened studies and reviews. First, we scanned titles and abstracts to select RCTs for further consideration. Then, we scanned the full texts of the selected articles for inclusion. The decision on inclusion of each RCT was determined by the consensus between the 2 independent reviewers (NR and DD).
Inclusion/Exclusion Criteria and Types of Outcome
We included all RCTs that directly compared SB with SF in acute syndesmotic diastasis injuries in human participants. We excluded all RCTs that did not provide outcome of interest and that reported any dynamic stabilization methods other than SB. We measured functional outcome and postoperative complications. Most of the RCTs provided information on the functional outcome, using AOFAS, OMA, or ROM. The American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale from 0 to 100 points is divided into 3 parts describing pain, function, and alignment, with 100 being the best result. 19 The Olerud-Molander Ankle (OMA) scale from 0 to 100 points is a self-reported functional scoring system, with 100 being the best score. 28 We accepted the evaluation of AOFAS and OMA at <6, 6, 12, or ≥24 months postoperatively. We used the time points with the largest number of observations of reported AOFAS and OMA, in case that it was observed more than once <6 or ≥24 months postoperatively. The normal ROM of the ankle joint is approximately 15 degrees for dorsiflexion (extension) and 30 degrees for plantarflexion. 37 It strongly reflects the function of the joint. Complication is defined as a secondary adverse event, or development leads to a more difficult course of therapy. Postoperative complications such as implant irritation, implant failure (including screw breakage), joint malreduction, reoperation (including planned removal), and other complications were investigated.
Data Extraction and Risk of Bias and Level of Evidence Assessment
Two reviewers (NR and DD) extracted the following data: first author, year of publication, number of patients, patient characteristics, follow-up period, implant used, and fracture type. In several cases, standard deviation (SD) had to be calculated by the statistician, because some RCTs reported only the range of numbers. The SD calculation was conducted according to the following formula: (higher range value – lower range value)/4.16,17 In case that the RCTs provided different information on intention to treat (ITT) and per protocol (PP) analysis, we used the numbers from the ITT analysis. We assessed the RCTs for their risk of bias and level of evidence, according to Cochrane’s Risk of Bias 2 (RoB 2) tool and the guidelines of the Centre for Evidence-Based Medicine.3,38
Meta-analysis: Measures of Treatment Effect
In our statistics, the SB group was named “experimental group” and the SF group was named “control group.” We tested both fixed (FE) and random effects (RE) models. RE models provided more reliable results, so we proceeded as follows: We calculated mean differences (MDs) with 95% CIs for continuous outcomes, using the Hartung-Knapp-Sidik-Jonkman method and an RE model. We calculated the odds ratio (OR) and their 95% CIs for dichotomous outcomes, using the Mantel-Haenszel method and an RE model. Study weighting was performed by inverse variance. We calculated prediction intervals to estimate where to expect the next data point sampled. We calculated the t test to determine statistically significant differences between the means of the 2 groups. We used a significance level of P = .05. Heterogeneity was assessed using Cochrane’s Q test (P value <.10 is indicative of heterogeneity) and Higgins test I² (low heterogeneity: <25%, moderate heterogeneity: 25%-75%, and high heterogeneity: >75%). 18 All statistic calculations were conducted by a professional statistician, using the R packages meta and metafor.35,42 We presented our results in Forest, Baujat, and Funnel plots.
Results
Study Identification and Selection
Overall, 1815 studies were found in initial literature search and screened by titles and abstracts according to our predefined inclusion criteria, as noted in the PRISMA flow diagram (Figure 1). After full-text analysis, 7 RCTs left for further consideration.1,6,21,22,31,32,34 Two of them used the same initial data.1,32 We included the study that gave us more information and had the lower risk of bias. 32 Furthermore, we identified 1 more RCT by citation search 5 and by search of Google Scholar, 14 leaving a total of 8 RCTs for inclusion in final meta-analysis.5,6,14,21,22,31,32,34
Figure 1.
PRISMA flow diagram.
Characteristics of the RCTs
Table 1 shows the main characteristics of the 8 included RCTs. These studies were published between 2009 and 2020, altogether involving 569 patients. Two hundred seventy-eight of the included patients (average age 40.6 years) were operated with SB, and 291 of the included patients (average age 40 years) were operated with SF. The sample size of these trials ranged from 24 to 113 patients, and the follow-up period ranged from 12 to 60 months. Four of 8 RCTs did not report SD.5,14,31,32 All studies were published in English language. The follow-up period ranged from 12 to 60 months. The RCTs included all kind of ankle injuries (fractures and ligament ruptures) leading to acute syndesmotic diastasis, requiring operative treatment. Table 2 shows the summarized risk of bias assessment. One study of 8 was an anonymized RCT with a level I evidence 6 ; the other 7 studies were non anonymized RCTs with level II evidence.5,14,21,22,31,32,34
Table 1.
Main Characteristics of the 8 Included RCTs.
| Sample Size, n | Surgical Approach, n | Age, y, Mean (SD) | Gender, male/Female, n | Follow-up Period, mo | Implant Used | Planned Implant Removal | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Study | Pts | SB | SF | SB | SF | SB | SF | SB | SF | SB | SF | |
| Coetzee and Ebeling (2009) 5 | 24 | 12 | 12 | 35 (9) | 38 (9) | 9/3 | 8/4 | 27 | 27 | 2 tightrope, except of 1 with 1 tightrope | 4.0-mm, 4.5-mm, and 6.5-mm screws | No |
| Colcuc et al (2018) 6 | 54 | 26 | 28 | 35 (11) | 39 (11) | 19/7 | 22/6 | 12 | 12 | 1 knotless tightrope | One 3.5-mm screw, 4 cortices | Planned screw removal |
| Giza et al (2019) 14 | 65 | 32 | 33 | 38 (15) | 31 (9) | 8/24 | 9/24 | 12 | 12 | 1 or 2 tightropes, knotless or not | 1 or 2 screws | No |
| Kortekangas et al (2015) 21 | 43 | 21 | 22 | 46 (15) | 44 (16) | 13/8 | 14/8 | 36 | 39 | 1 tightrope | One 3.5-mm screw, 3 cortices | No |
| Laflamme et al (2015) 22 | 70 | 34 | 36 | 40 (15) | 39 (12) | 25/9 | 26/10 | 12 | 12 | 1 tightrope | One 3.5-mm screw, 3 cortices | No |
| Raeder et al (2020) 31 | 113 | 55 | 58 | 44 (15) | 48 (14) | 35/20 | 30/38 | 24 | 24 | 1 knotless tightrope | One 3.5-mm screw, 3 cortices | No |
| Raeder et al (2020) 32 | 97 | 48 | 49 | 46 (15) | 43 (16) | 34/14 | 30/19 | 60 | 60 | 1 tightrope | One 4.5-mm screw, 4 cortices | Planned screw removal |
| Sanders et al (2019) 34 | 103 | 50 | 53 | 41 (12) | 38 (14) | 39/11 | 38/15 | 12 | 12 | 1 knotless tightrope | Two 3.5-mm screws, 3 cortices | 8 of 53 SF patients had planned screw removal |
Abbreviations: Pts, patients; SB, suture button; SF, screw fixation; RCT, randomized controlled trials.
Table 2.
Risk of bias summary.
| Random sequence generation (selection bias) | Allocation concealment (selection bias) | Blinding of participants and personnel (performance bias) | Incomplete outcome data (attrition bias) | Selective reporting (reporting bias) | Other bias | Overall risk of bias |
|---|---|---|---|---|---|---|
| ||||||
Abbreviations: Y, yes; N, no; U, unclear.
Functional Outcomes
AOFAS
AOFAS score <6 months postoperatively
Data on 399 patients (including 195 patients with SB and 204 patients with SF) were pooled from 5 RCTs. Compared with the SF group, the AOFAS <6 months postoperatively was 4.7 points higher in the SB group (MD = 4.74, 95% CI 1.68-7.80, I2 = 27%, P = .01; Figure 2).
Figure 2.
Forest plot of functional outcome (AOFAS and OMA) between SB and SF techniques. AOFAS, American Orthopaedic Foot & Ankle Society score; IV, inverse variance; OMA, Olerud-Molander Ankle score.
AOFAS score 6 months postoperatively
Data on 423 patients (including 207 patients with SB and 216 patients with SF) were pooled from 6 RCTs. There was no difference in AOFAS scores 6 months postoperatively between the SB and SF groups (MD = 0.63, 95% CI −3.11 to 4.36, I2 = 75%, P = .68; Figure 2).
AOFAS score 12 months postoperatively
Data on 423 patients (including 207 patients with SB and 216 patients with SF) were pooled from 6 RCTs. Compared with the SF group, the AOFAS scores 12 months postoperatively was 5.4 points higher in the SB group (MD = 5.42, 95% CI 1.50-9.33, I2 = 88%, P = .02; Figure 2).
AOFAS score ≥24 months postoperatively
Data on 234 patients (including 115 patients with SB and 119 patients with SF) were pooled from 3 RCTs. There was no difference in AOFAS ≥24 months postoperatively between the SB and SF groups (MD = 5.60, 95% CI −7.41 to 18.60, I2 = 98%, P = .21; Figure 2).
OMA
OMA score <6 months postoperatively
Data on 324 patients (including 158 patients with SB and 166 patients with SF) were pooled from 4 RCTs. There was no difference in OMA score <6 months postoperatively between the SB and SF groups (MD = 4.81, 95% CI −5.45 to 15.08, I2 = 68%, P = .23; Figure 2).
OMA score 6 months postoperatively
Data on 324 patients (including 158 patients with SB and 166 patients with SF) were pooled from 4 RCTs. There was no difference in OMA score 6 months postoperatively between the SB and SF groups (MD = 6.17, 95% CI −5.70 to 18.05, I2 = 88%, P = .20; Figure 2).
OMA score 12 months postoperatively
Data on 480 patients (including 234 patients with SB and 246 patients with SF) were pooled from 6 RCTs. There was no difference in OMA score 12 months postoperatively between the SB and SF groups (MD = 4.00, 95% CI −0.96 to 8.96, I2 = 90%, P = .09; Figure 2).
OMA score ≥24 months postoperatively
Data on 253 patients (including 124 patients with SB and 129 patients with SF) were pooled from 3 RCTs. There was no difference in OMA score ≥24 months postoperatively between the SB and SF groups (MD = 0.98, 95% CI −26.96 to 25.00, I2 = 93%, P = .89; Figure 2).
ROM
Dorsiflexion 6 months postoperatively
Data on 207 patients (including 101 patients with SB and 106 patients with SF) were pooled from 3 RCTs. There was no difference in dorsiflexion 6 months postoperatively between the SB and SF groups (MD = 1.44, 95% CI −1.29 to 4.17, I2 = 0%, P = .15; Figure 3).
Figure 3.
Forest plot of functional outcome (ROM) between the SB and SF techniques. IV, inverse variance; ROM, range of motion.
Dorsiflexion ≥ 12 months postoperatively
Data on 304 patients (including 149 patients with SB and 155 patients with SF) were pooled from 4 RCTs. There was no difference in dorsiflexion ≥12 months postoperatively between the SB and SF groups (MD = −0.84, 95% CI −5.44 to 3.77, I2 = 89%, P = .60; Figure 3).
Plantarflexion 6 months postoperatively
Data on 207 patients (including 101 patients with SB and 106 patients with SF) were pooled from 3 RCTs. There was no difference in plantarflexion 6 months postoperatively between the SB and SF groups (MD = 0.61, 95% CI −9.52 to 10.73, I2 = 66%, P = .82; Figure 3).
Plantarflexion ≥12 months postoperatively
Data on 304 patients (including 149 patients with SB and 155 patients with SF) were pooled from 4 RCTs. There was no difference in plantar flexion ≥12 months postoperatively between the SB and SF groups (MD = 1.62, 95% CI −4.86 to 8.10, I2 = 51%, P = .48; Figure 3).
Complications
Implant irritation
Data on 472 patients (including 230 patients with SB and 242 patients with SF) were pooled from 7 RCTs. Compared with the SF group, the frequency of risk for implant irritation was lower in the SB group (OR = 0.31, 95% CI 0.11-0.89, I2 = 22%, P = .03; Figure 4).
Figure 4.
Forest plot of complications rates between the SB and SF techniques. MH, Mantel-Haenszel.
Implant failure
Data on 401 patients (including 196 patients with SB and 205 patients with SF) were pooled from 6 RCTs. Compared with the SF group, the frequency of risk for implant failure was lower in the SB group (OR = 0.06, 95% CI 0.02-0.23, I2 = 0%, P < .01; Figure 4).
Joint malreduction
Data on 545 patients (including 266 patients with SB and 279 patients with SF) were pooled from 7 RCTs. There was no difference in the frequency of joint malreduction between the SB and SF groups (OR = 0.55, 95% CI 0.27-1.11, I2 = 25%, P = .10; Figure 4).
Reoperation
Data on 369 patients (including 180 patients with SB and 189 patients with SF) were pooled from 6 RCTs. Compared with the SF group, the frequency of risk for reoperation was lower in the SB group (OR = 0.43, 95% CI 0.22-0.83, I2 = 0%, P = .01; Figure 4).
Other complications
Data on 401 patients (including 196 patients with SB and 205 patients with SF) were pooled from 6 RCTs. There was no difference in the frequency of other complications between the SB and SF groups (OR = 1.12, 95% CI 0.32-3.86, I2 = 31%, P = .86; Figure 4).
Baujat and Funnel plots are given in the supplemental material
Discussion
Eight RCTs with 569 patients were included in this meta-analysis. The SB group consisted of 278 patients, and the SF group consisted of 291 patients. One study among 8 was an anonymized RCT with a level I evidence, 6 the other 7 studies were nonanonymized RCTs with level II evidence.5,14,21,22,31,32,34 The value of this meta-analysis results from the limitation of inclusion criteria to RCTs and use of high-quality statistical methods. It offers the highest sample size of all RCT meta-analyses11,15,29,36 on this topic (Table 3). However, our meta-analysis concentrated only on decisive outcome parameters in order to maintain transparency of the results. SB showed slightly better functional results. The main advantage of SB is in the lower risk for postoperative complications compared with SF. The SB technique had fewer cases of implant irritation, implant failure, and reoperation. Joint malreduction and other complications showed no difference between SB and SF.
Table 3.
Comparison with related meta-analyses.
| Meta-analysis (year) | Sample Size | Studies Included | Comment |
|---|---|---|---|
| Chen et al (2019) 4 | 397 | 3 RCTs 6 non-RCTs |
Almost same studies included as Fan et al (2019) 10 and Gan et al (2019) 12 |
| Fan et al (2019) 10 | 420 | 3 RCTs 7 non-RCTs |
Same studies included as Gan et al (2019) 12 |
| Gan et al (2019) 12 | 282 | 5 RCTs | Same RCTs included as Onggo et al (2020)
29
Shimozono et al (2019), 36 different sample size, partly different results |
| Gan et al (2019) 12 | 420 | 3 RCTs 7 non-RCTs |
Same studies included as Fan et al (2019) 10 |
| Grassi et al (2020) 15 | 335 | 7 RCTs | All types of dynamic fixation techniques |
| McKenzie et al (2019) 26 | 275 | 2 RCTs 4 non-RCTs |
Lowest sample size |
| Onggo et al (2020) 29 | 280 | 5 RCTs | Same RCTs included as Gan et al (2019),
12
Shimozono et al (2019), 36 different sample size, partly different results |
| Shimozono et al (2019) 36 | 285 | 5 RCTs | Same RCTs included as Gan et al (2019),
12
Onggo et al (2020), 29 different sample size, partly different results |
| Xie et al (2018) 45 | 539 | 5 RCTs 6 non-RCTs |
– |
| Xu et al (2021) 46 | 654 | 6 RCTs 6 non-RCTs |
Highest sample size |
| Zhang et al (2017) 47 | 390 | 3 RCTs 6 non-RCTs |
Almost same studies included as Fan et al (2019) 10 and Gan et al (2019) 12 |
Abbreviation: RCT, randomized controlled trial.
We measured the functional outcome with information on AOFAS and OMA scores and ROM. SB showed slightly better functional results. The AOFAS score <6 months postoperatively was 4.7 points higher and 12 months postoperatively 5.4 points higher in the SB group compared with the SF group. AOFAS scores 6 and ≥ 24 months postoperatively, OMA score, and ROM showed no difference between the SB and SF groups. The minimal clinically important difference is the smallest change in patient outcome that would require a change in patient management. 24 Because there are no fixed reference values for the ankle with regard to the minimal clinically important difference, we can only estimate that a difference of about 5 does not seem clinically relevant. Therefore, it is questionable whether a change in the surgical techniques by the operators is justified on the basis of functional outcome.
Our findings showed major differences in postoperative complications regarding implant irritations, implant failure, and reoperation. The incidence of implant irritations occurred in 3% of patients operated with the SB technique and in 11% of patients operated with the SF technique. Local tissue irritation is a frequent reason for implant removal in cases with SF. Furthermore, it is believed that the SB knot is more tolerable for the tissue than the screw head. The incidence of implant failure occurred in 0% of patients operated with SB technique and in 18% of patients operated with the SF technique, which is a very obvious advantage for the SB technique. The fact that the SB implant is flexible and the SF is rigid might play a role in regard to implant failure. Some studies have shown it is possible to initiate full weightbearing earlier following SB technique.7,27,40 Earlier full weightbearing might cause screw breakage before the syndesmosis healing process is complete. Malreduction of the syndesmosis is a very important predictor of the long-term outcome after treatment of ankle fractures. 43 However, we did not find any difference in malreduction between the 2 groups. In this context, however, 1 detail must be taken into account. The study by Raeder et al 32 had a very high contribution to the overall result, as it is obvious from the Baujat plot (see supplemental material), which had a study weight of 34.5% (see Figure 4). The results of this study differ significantly from the rest of the included RCTs with regard to malreduction. The incidence of syndesmotic malreduction occurred in 58% of patients operated with the SB technique and in 53% of patients operated with the SF technique in the RCT by Raeder et al. 32 It occurred in 5% of patients operated with SB technique and in 14% of patients operated with the SF technique in the rest of the included RCTs. The very high incidence of syndesmotic malreduction in both SB and SF groups examined in the RCT by Raeder et al 32 might be explained by the fact that their research group determined the radiologic position of the syndesmosis by CT scan. In addition, this study had the longest follow-up period. The incidence of reoperation occurred in 9% of patients operated with the SB technique and in 14% of patients operated with the SF technique. The higher reoperation rate is certainly a consequence of the higher complication rate with the SF technique than the SB technique. Other complications did not show any difference between the SB and SF techniques. There is 1 possible complication that neither RCT might have considered. Is it conceivable that the SB construct stretches or even erodes into the bone over time. A broken screw is very clearly visible in conventional radiographs; the elongation within the SB construct is less visible. A fairer and more accurate comparison would be the assessment of the radiologic diastase between the 2 constructs under CT scan. Another major point of discussion is that some of the included RCTs had planned screw removal6,32,34 and others did not.5,14,21,22,31 This acts as a confounding factor on the outcome parameters “reoperation” and “implant failure.” However, it must be said that the planned screw removal still is a reoperation with all the associated risks. If a screw removal is not planned, a screw breakage after achieving full weightbearing is not unlikely. However, this must also be viewed critically, as a delayed diastasis can also occur in due course after screw breakage.
By making an overview of related meta-analyses, some peculiarities catch the eye (Table 3). There are 4 related RCT meta-analyses.11,15,29,36 First of all, the 2019 meta-analysis by Grassi et al 15 included 335 patients from 7 RCTs providing information on all types of dynamic stabilization techniques.1,5,6,21,22,25,44 Two of them reported results of surgery by wire cerclages 25 and elastic hook plates. 44 Therefore, the results are comparable to a limited extent. However, the 2019 meta-analysis by Grassi et al 15 found that dynamic fixation of syndesmotic injuries reduced the risk of complications and reoperation and improved clinical outcomes as compared to static screw fixation. Three further related RCT meta-analyses11,29,36 included exactly the same 5 RCTs.1,5,6,21,22 All of these RCTs were found in our literature search. However, we excluded one of them, namely, the 2018 RCT by Andersen et al 1 that used the same initial data as another RCT 32 we found. Therefore, we included the RCT that gave us more information and had the lower risk of bias, namely, the 2020 RCT by Raeder et al. 32 Furthermore, we found 3 more RCTs14,31,34 that were not found in the related RCT meta-analyses.11,15,29,36 When comparing the 3 meta-analysis, it is immediately noticeable that although the same RCT were included, different statements were made regarding the sample size, namely, 282 patients in the 2020 meta-analysis by Gan et al, 11 280 patients in the 2020 meta-analysis by Onggo et al, 29 and 285 patients by Shimozono et al in 2019. 36 A very important limitation of the 2019 RCT meta-analysis by Shimozono et al 36 was that the authors performed statistics using an FE model. The authors should have avoided FE models because such models underperform in the presence of any heterogeneity. RE models are more conservative, provide better estimates with wider CIs, and the results are more scientifically generalizable.2,20 However, the 2019 RCT meta-analysis by Shimozono et al 36 found that the SB technique improved functional outcomes and reduced the risk of implant breakage and joint malreduction as compared to the SF technique. The 2020 meta-analysis by Gan et al 11 and the 2020 meta-analysis by Onggo et al 29 were performed using RE models. Onggo et al 29 even tested FE and RE models as we did in our study. When comparing the 2 RCT meta-analyses, it is noticeable that in addition to different total sample sizes, different data were extracted for AOFAS and OMA scores 12 months postoperatively and DF and PF 6 months postoperatively, leading to different results and partly different conclusions. Another difference between both meta-analyses is that the 2020 meta-analysis by Onggo et al 29 distinguished between types of postoperative complications, whereas the 2020 meta-analysis by Gan et al 11 presented postoperative complications as one single outcome parameter. However, the 2020 meta-analysis by Onggo et al 29 found that the SB technique improved AOFAS score 12 months postoperatively and reduced the risk for implant failures compared with the SF technique. The 2020 meta-analysis by Gan et al 11 stated that the SB technique improved functional outcomes and reduced the risk for overall postoperative complications compared with the SF technique.
When comparing the non-RCT meta-analyses,4,10,12,26,45,46,47 it is again noticeable that several of them included exactly the same studies, namely, the 2019 meta-analysis by Fan et al 10 and the 2019 meta-analysis by Gan et al, 12 or almost the same studies, namely, the 2019 meta-analysis by Chen et al 4 and the 2017 meta-analysis by Zhang et al. 47 The 2019 meta-analysis by McKenzie et al 26 had a very small sample size considering that it was not limited to RCTs. Considering good scientific practice, some of these meta-analyses were unnecessary to publish. However, their overall results were in consistency with the results of the RCT meta-analyses.
We identified the following limitations of this meta-analysis: first, this meta-analysis did not consider the possible influence of the operating surgeon and the use of different implant brands; second, there are differences between the included RCTs in the number, positioning, and size of screws and the number of SBs used; third, there are differences between the included RCTs in ankle injury patterns; fourth, the information on postoperative complications was collected at different time points among the included RCTs; fifth, in some RCTs, there was planned implant removal and in others not, which influences the outcome parameter “reoperation.” All of these points might have an impact on the results. Nevertheless, there are still not enough RCTs to conduct a meta-analysis taking into account these limitations.
Conclusions
Our overall findings suggested slightly better outcomes of SB compared with SF. Because functional outcomes showed no relevant difference between SB and SF, the advantage of SB appears to be a lower risk for postoperative complications. The SB technique was found to have fewer cases of implant irritation, implant failure, and reoperation compared with SF.
Supplemental Material
Supplemental material, sj-zipx-1-fao-10.1177_24730114211061405 for Comparison of Outcomes Between Suture Button Technique and Screw Fixation Technique in Patients With Acute Syndesmotic Diastasis: A Meta-analysis of Randomized Controlled Trials by Nikolai Ramadanov, Simon Bueschges and Dobromir Dimitrov in Foot & Ankle Orthopaedics
Footnotes
Author Note: Nikolai Ramadanov author is now affiliated to Center of Orthopaedics and Traumatology, University Hospital Brandenburg an der Havel, Brandenburg Medical School Theodor Fontane, Germany.
Ethical Approval: Ethical approval was not sought for the present study because this is a systematic review and meta-analysis.
Declaration of Conflicting Interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. ICMJE forms for all authors are available online.
Funding: The author(s) received no financial support for the research, authorship, and/or publication of this article.
ORCID iD: Nikolai Ramadanov, MD,
https://orcid.org/0000-0003-4669-8187
Supplemental Material: Supplementary material is available online with this article.
References
- 1. Andersen MR, Frihagen F, Hellund JC, Madsen JE, Figved W. Randomized trial comparing suture button with single syndesmotic screw for syndesmosis injury. J Bone Joint Surg Am. 2018;100:2-12. doi: 10.2106/JBJS.16.01011. [DOI] [PubMed] [Google Scholar]
- 2. Brockwell SE, Gordon IR. A comparison of statistical methods for meta-analysis. Stat Med. 2001;20(6):825-840. doi: 10.1002/sim.650. [DOI] [PubMed] [Google Scholar]
- 3. Centre for Evidence-Based Medicine. Levels of evidence (March 2009). Accessed July 8, 2011. http://www.cebm.net/index.aspx?o=1025
- 4. Chen B, Chen C, Yang Z, Huang P, Dong H, Zeng Z. To compare the efficacy between fixation with tightrope and screw in the treatment of syndesmotic injuries: a meta-analysis. Foot Ankle Surg. 2019;25(1):63-70. doi: 10.1016/j.fas.2017.08.001. [DOI] [PubMed] [Google Scholar]
- 5. Coetzee JC, Ebeling PB. Treatment of syndesmoses disruptions: A prospective, randomized study comparing conventional screw fixation vs TightRope® fiber wire fixation – medium term results. SA Othop J. 2009;8(1):6. [Google Scholar]
- 6. Colcuc C, Blank M, Stein T, Raimann F, Weber-Spickschen S, Fischer S, Hoffmann R. Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device. Knee Surg Sports Traumatol Arthrosc. 2018;26(10):3156-3164. doi: 10.1007/s00167-017-4820-3. [DOI] [PubMed] [Google Scholar]
- 7. Cottom JM, Hyer CF, Philbin TM, Berlet GC. Treatment of syndesmotic disruptions with the Arthrex TightRope: a report of 25 cases. Foot Ankle Int. 2008;29(8):773-780. doi: 10.3113/FAI.2008.0773. [DOI] [PubMed] [Google Scholar]
- 8. de-Las-Heras Romero J, Alvarez AML, Sanchez FM, et al. Management of syndesmotic injuries of the ankle. EFORT Open Rev. 2017;2(9):403–409. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Elsoe R, Ostgaard SE, Larsen P. Population-based epidemiology of 9767 ankle fractures. Foot Ankle Surg. 2018;24(1):34–39. [DOI] [PubMed] [Google Scholar]
- 10. Fan X, Zheng P, Zhang YY, Hou ZT. Dynamic fixation versus static fixation in treatment effectiveness and safety for distal tibiofibular syndesmosis injuries: a systematic review and meta-analysis. Orthop Surg. 2019;11(6):923-931. doi: 10.1111/os.12523 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Gan K, Xu D, Hu K, Wu W, Shen Y. Dynamic fixation is superior in terms of clinical outcomes to static fixation in managing distal tibiofibular syndesmosis injury. Knee Surg Sports Traumatol Arthrosc. 2020;28(1):270-280. doi: 10.1007/s00167-019-05659-0. [DOI] [PubMed] [Google Scholar]
- 12. Gan K, Zhou K, Hu K, Lu L, Gu S, Shen Y. Dynamic fixation versus static fixation for distal tibiofibular syndesmosis injuries: a meta-analysis. Med Sci Monit. 2019;25:1314-1322. doi: 10.12659/MSM.913324. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Gardner MJ, Demetrakopoulos D, Briggs SM, Helfet DL, Lorich DG. Malreduction of the tibiofibular syndesmosis in ankle fractures. Foot Ankle Int. 2006;27(10):788–792. [DOI] [PubMed] [Google Scholar]
- 14. Giza E, Oliver T, Kreulen C, et al. A prospective, randomized suture-button vs screw syndesmotic fixation. Foot Ankle Orthop. 2019;4(4). doi: 10.1177/2473011419S00185. [DOI] [Google Scholar]
- 15. Grassi A, Samuelsson K, D’Hooghe P, et al. Dynamic stabilization of syndesmosis injuries reduces complications and reoperations as compared with screw fixation: a meta-analysis of randomized controlled trials. Am J Sports Med. 2020;48(4):1000-1013. doi: 10.1177/0363546519849909. [DOI] [PubMed] [Google Scholar]
- 16. Higgins JPT, Deeks J. Selecting studies and collecting data. In: Higgins JPT, Green S, eds. Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0. The Cochrane Collaboration; 2011:chap 7. [Google Scholar]
- 17. Higgins JPT, Deeks J, Altman D. Special topics in statistics. In: Higgins JPT, Green S. eds. Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0. The Cochrane Collaboration; 2011:chap 16. [Google Scholar]
- 18. Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med. 2002;21:1539–1558. [DOI] [PubMed] [Google Scholar]
- 19. Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M. Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int. 1994;15(7):349-353. [DOI] [PubMed] [Google Scholar]
- 20. Kontopantelis E, Reeves D. Performance of statistical methods for meta-analysis when true study effects are non-normally distributed: a simulation study. Stat Methods Med Res. 2012;21(4):409-426. doi: 10.1177/0962280210392008. [DOI] [PubMed] [Google Scholar]
- 21. Kortekangas T, Savola O, Flinkkilä T, et al. A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography. Injury. 2015;46(6):1119-1126. doi: 10.1016/j.injury.2015.02.004. [DOI] [PubMed] [Google Scholar]
- 22. Laflamme M, Belzile EL, Bédard L, van den Bekerom MP, Glazebrook M, Pelet S. A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture. J Orthop Trauma. 2015;29(5):216-223. doi: 10.1097/BOT.0000000000000245. [DOI] [PubMed] [Google Scholar]
- 23. Lauge-Hansen N. Ligamentous ankle fractures; diagnosis and treatment. Acta Chir Scand. 1949;97(6):544-550. [PubMed] [Google Scholar]
- 24. Maltenfort MG. The minimally important clinical difference. Clin Spine Surg. 2016;29(9):383. doi: 10.1097/BSD.0000000000000446. [DOI] [PubMed] [Google Scholar]
- 25. Massobrio M, Antonietti G, Albanese P, Necci F. Operative treatment of tibiofibular diastasis: a comparative study between transfixation screw and reabsorbable cerclage. Preliminary result. Clin Ter. 2011;162(6):e161-e167. [PubMed] [Google Scholar]
- 26. McKenzie AC, Hesselholt KE, Larsen MS, Schmal H. A systematic review and meta-analysis on treatment of ankle fractures with syndesmotic rupture: suture-button fixation versus cortical screw fixation. J Foot Ankle Surg. 2019;58(5):946-953. doi: 10.1053/j.jfas.2018.12.006. [DOI] [PubMed] [Google Scholar]
- 27. Naqvi GA, Shafqat A, Awan N. Tightrope fixation of ankle syndesmosis injuries: clinical outcome, complications and technique modification. Injury. 2012;43(6):838-842. doi: 10.1016/j.injury.2011.10.002. [DOI] [PubMed] [Google Scholar]
- 28. Olerud C, Molander H. A scoring scale for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg. 1984;103(3):190-194. [DOI] [PubMed] [Google Scholar]
- 29. Onggo JR, Nambiar M, Phan K, et al. Suture button versus syndesmosis screw constructs for acute ankle diastasis injuries: a meta-analysis and systematic review of randomised controlled trials. Foot Ankle Surg. 2020;26(1):54-60. doi: 10.1016/j.fas.2018.11.008. [DOI] [PubMed] [Google Scholar]
- 30. Petscavage JM, Perez F, Khorashadi L, Richardson ML. Tightrope walking: a new technique in ankle syndesmosis fixation. Radiol Case Rep. 2010;5(1):354. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Raeder BW, Stake IK, Madsen JE, et al. Randomized trial comparing suture button with single 3.5 mm syndesmotic screw for ankle syndesmosis injury: similar results at 2 years. Acta Orthop. 2020;91(6):770-775. doi: 10.1080/17453674.2020.1818175. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Raeder BW, Figved W, Madsen JE, Frihagen F, Jacobsen SB, Andersen MR. Better outcome for suture button compared with single syndesmotic screw for syndesmosis injury: five-year results of a randomized controlled trial. Bone Joint J. 2020;102-B(2):212-219. doi: 10.1302/0301-620X.102B2.BJJ-2019-0692.R2. [DOI] [PubMed] [Google Scholar]
- 33. Sagi HC, Shah AR, Sanders RW. The functional consequence of syndesmotic joint malreduction at a minimum 2-year follow-up. J Orthop Trauma. 2012;26(7):439–443. [DOI] [PubMed] [Google Scholar]
- 34. Sanders D, Schneider P, Taylor M, Tieszer C, Lawendy AR; Canadian Orthopaedic Trauma Society. Improved reduction of the tibiofibular syndesmosis with TightRope compared with screw fixation: results of a randomized controlled study. J Orthop Trauma. 2019;33(11):531-537. doi: 10.1097/BOT.0000000000001559. [DOI] [PubMed] [Google Scholar]
- 35. Schwarzer G. Meta: An R package for meta-analysis. R News. 2007;7(3):40-45. [Google Scholar]
- 36. Shimozono Y, Hurley ET, Myerson CL, Murawski CD, Kennedy JG. Suture button versus syndesmotic screw for syndesmosis injuries: a meta-analysis of randomized controlled trials. Am J Sports Med. 2019;47(11):2764-2771. doi: 10.1177/0363546518804804. [DOI] [PubMed] [Google Scholar]
- 37. Soucie JM, Wang C, Forsyth A, et al. ; Hemophilia Treatment Center Network. Range of motion measurements: reference values and a database for comparison studies. Haemophilia. 2011;17(3):500-507. doi: 10.1111/j.1365-2516.2010.02399.x. [DOI] [PubMed] [Google Scholar]
- 38. Sterne JAC, Savović J, Page MJ, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. 2019. BMJ. 366:14898. www.riskofbias.info(10.01.2020) [DOI] [PubMed] [Google Scholar]
- 39. Thornes B. Ankle syndesmosis injuries treated with the TightRope TM suture button kit technique. Foot Ankle Surg. 2006;5(1):1 [Google Scholar]
- 40. Thornes B, Shannon F, Guiney AM, Hession P, Masterson E. Suture-button syndesmosis fixation: accelerated rehabilitation and improved outcomes. Clin Orthop Relat Res. 2005;431:207-212. [PubMed] [Google Scholar]
- 41. van den Bekerom MP, Hogervorst M, Bolhuis HW, van Dijk CN. Operative aspects of the syndesmotic screw: review of current concepts. Injury. 2008;39(4):491–498. [DOI] [PubMed] [Google Scholar]
- 42. Viechtbauer W. Conducting meta-analyses in R with the metafor package. 2010. J Stat Softw. 36(3):1-48. [Google Scholar]
- 43. Weening B, Bhandari M. Predictors of functional outcome following transsyndesmotic screw fixation of ankle fractures. J Orthop Trauma. 2005;19(2):102-108. doi: 10.1097/00005131-200502000-00006. [DOI] [PubMed] [Google Scholar]
- 44. Xian H, Miao J, Zhou Q, Lian K, Zhai W, Liu Q. Novel elastic syndesmosis hook plate fixation versus routine screw fixation for syndesmosis injury. J Foot Ankle Surg. 2018;57(1):65-68. doi: 10.1053/j.jfas.2017.08.007. [DOI] [PubMed] [Google Scholar]
- 45. Xie L, Xie H, Wang J, et al. Comparison of suture button fixation and syndesmotic screw fixation in the treatment of distal tibiofibular syndesmosis injury: a systematic review and meta-analysis. Int J Surg. 2018;60:120-131. doi: 10.1016/j.ijsu.2018.11.007. [DOI] [PubMed] [Google Scholar]
- 46. Xu K, Zhang J, Zhang P, et al. Comparison of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury: a meta-analysis. J Foot Ankle Surg. 2021;60(3):555-566. doi: 10.1053/j.jfas.2020.08.005. [DOI] [PubMed] [Google Scholar]
- 47. Zhang P, Liang Y, He J, Fang Y, Chen P, Wang J. A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury. BMC Musculoskelet Disord. 2017;18(1):286. doi: 10.1186/s12891-017-1645-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Supplemental material, sj-zipx-1-fao-10.1177_24730114211061405 for Comparison of Outcomes Between Suture Button Technique and Screw Fixation Technique in Patients With Acute Syndesmotic Diastasis: A Meta-analysis of Randomized Controlled Trials by Nikolai Ramadanov, Simon Bueschges and Dobromir Dimitrov in Foot & Ankle Orthopaedics




