Skip to main content
BMJ Open Access logoLink to BMJ Open Access
. 2021 Mar 29;31(1):23–30. doi: 10.1136/bmjqs-2021-013015

Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals

Vineet Chopra 1,2,3,, Megan O'Malley 1,3, Jennifer Horowitz 1,3, Qisu Zhang 1,3, Elizabeth McLaughlin 1,3, Sanjay Saint 1,2, Steven J Bernstein 3, Scott Flanders 1,3
PMCID: PMC8685627  PMID: 33782091

Abstract

Background

The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) provides evidence-based criteria for peripherally inserted central catheter (PICC) use. Whether implementing MAGIC improves PICC appropriateness and reduces complications is unknown.

Methods

A quasiexperimental study design to implement MAGIC in 52 Michigan hospitals was used. Data were collected from medical records by trained abstractors. Hospital performance on three appropriateness criteria was measured: short-term PICC use (≤5 days), use of multilumen PICCs and PICC placement in patients with chronic kidney disease. PICC appropriateness and device complications preintervention (January 2013 to December 2016) versus postintervention (January 2017 to January 2020) were compared. Change-point analysis was used to evaluate the effect of the intervention on device appropriateness. Logistic regression and Poisson models were fit to assess the association between appropriateness and complications (composite of catheter occlusion, venous thromboembolism (VTE) and central line-associated bloodstream infection (CLABSI)).

Results

Among 38 592 PICCs, median catheter dwell ranged from 8 to 56 days. During the preintervention period, the mean frequency of appropriate PICC use was 31.9% and the mean frequency of complications was 14.7%. Following the intervention, PICC appropriateness increased to 49.0% (absolute difference 17.1%, p<0.001) while complications decreased to 10.7% (absolute difference 4.0%, p=0.001). Compared with patients with inappropriate PICC placement, appropriate PICC use was associated with a significantly lower odds of complications (OR 0.29, 95% CI 0.25 to 0.34), including decreases in occlusion (OR 0.25, 95% CI 0.21 to 0.29), CLABSI (OR 0.61, 95% CI 0.46 to 0.81) and VTE (OR 0.40, 95% CI 0.33 to 0.47, all p<0.01). Patients with appropriate PICC placement had lower rate of complications than those with inappropriate PICC use (incidence rate ratio 0.987, 95% CI 0.98 to 0.99, p<0.001).

Conclusions

Implementation of MAGIC in Michigan hospitals was associated with improved PICC appropriateness and fewer complications. These findings have important quality, safety and policy implications for hospitals, patients and payors.

Keywords: critical care, healthcare quality improvement, hospital medicine, nosocomial infections

Introduction

Because they can be inserted at the bedside, are safer to insert than other central venous catheters and facilitate transitions of care, peripherally inserted central catheters (PICCs) have become one of the most prevalent vascular access devices in US hospitals.1 2 Like other central venous catheters, however, PICCs are associated with infectious and non-infectious risks including venous thromboembolism (VTE) and central line-associated bloodstream infection (CLABSI).3–6 Additionally, PICC occlusion remains one of the most common device-complications and leads to delays in treatment, increase in cost and in some cases, PICC replacement.7 8

One strategy to avoid PICC-related adverse events is to only place the device when it is appropriate: that is, when the benefits of use outweigh risks. The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) offers an evidence-based strategy to inform clinicians on when it is appropriate to place a PICC.9 Developed by a multidisciplinary panel, MAGIC provides appropriateness ratings for PICC use, taking into account duration of therapy, the type of infusion being delivered and the indication for treatment. Interventions using MAGIC have demonstrated more appropriate PICC use and a decrease in central line days and device utilisation.10 However, whether implementing MAGIC reduces device-related complications is not known. Improving PICC appropriateness while also reducing complications would make a compelling case for implementing MAGIC in hospitals.

In partnership with a statewide safety-focused collaborative, we designed a multimodal intervention to assess the impact of MAGIC on PICC appropriateness and device-associated complications.

Methods

Study, setting and design

We used data from the Michigan Hospital Medicine Safety (HMS) Consortium from 1 January 2013 to 13 January 2020 to examine the association between PICC appropriateness and major PICC-related complications (composite of CLABSI, VTE and catheter occlusion). A collaborative quality initiative funded by Blue Cross Blue Shield of Michigan and Blue Care Network, a core initiative of HMS is focused on measuring and improving PICC use and outcomes in participating hospitals.11 The design and setting of this project and the consortium have been previously described.12 13 Beginning 1 January 2013, trained abstractors at each hospital collected data using a defined protocol, sampling frame and standardised template. Hospitalised medical patients who received PICCs while admitted to a general medical ward or intensive care unit (ICU) during clinical care were eligible for inclusion. Patients were excluded if they were under the age of 18 years, pregnant, admitted to a non-medicine service (eg, surgery) or in observation status. Every 14 days, each hospital collected detailed data on the first 17 eligible patients that received a PICC at their facility, with at least 7 PICCs placed in an ICU setting. All patients were prospectively followed until the PICC was removed, a major complication or death occurred or 30-day elapsed following insertion (whichever occurred first). Follow-up occurred via a combination of medical record review (eg, chart abstraction) and telephone calls at 7, 14 and 30 days. To ensure data quality and integrity, annual data audits were performed at each participating hospital by the HMS coordinating centre at the University of Michigan.

Patient, provider and device data

Patient characteristics (eg, demographics, comorbidities, medications, physical findings, imaging and laboratory results) were abstracted from hospital medical records. For patients with more than one PICC, the first PICC was included and subsequent devices were excluded (n=2988). PICC characteristics, including indication for insertion, catheter gauge, number of lumens and insertion attempts, were abstracted from the physician order, the vascular access nurse insertion note or the radiology provider insertion note, as available. Provider characteristics, including the specialty of the attending physician and the operator that inserted the PICC were collected from medical records. In addition, data regarding consultation with specialists prior to PICC insertion (eg, nephrologists for PICC use in patients with chronic kidney disease (CKD)) were also recorded.

Implementation strategy and intervention design

To improve PICC appropriateness, we designed and implemented an evidence-based, pay-for-performance intervention based on MAGIC. We informed our intervention using theory-based guidance and used a Type 1 hybrid effectiveness implementation strategy, which focused on the effectiveness outcomes of an intervention, while exploring the ‘implementability’ of the same.14 The intervention was based on three targets aimed at corresponding appropriateness criteria: reducing short term PICC use (<5 days), decreasing use of multilumen devices and avoiding PICC placement in patients with CKD (defined as an estimated glomerular filtration rate <45 mL/min/1.73 m2), unless approved by a nephrologist prior to insertion. To reach these targets, hospitals were given access to a toolkit that consisted of: (a) an online learning platform;15 (b) access to subject matter experts; (c) knowledge sharing at quarterly in-person meetings and (d) feedback on performance via a central website. The toolkit included educational materials, summaries of best practices and peer-reviewed publications, electronic order-set templates, policies and protocols based on MAGIC, strategies to empower vascular access teams to make device decisions and tactics to engage subspecialists such as nephrologists and infectious diseases to approve PICC use in appropriate settings. The toolkit was introduced 1 January 2017 and is available online at: https://www.improvepicc.com/implementation.html. To complement the toolkit, quarterly in-person meetings where unblinded hospital performance data related to performance on appropriateness targets, examples of innovations and best practices across hospitals and challenges and solutions were featured. Participating sites received annual payments for their quality improvement efforts, with partial to full payment based on performance on each of the three criteria.

Assessing PICC appropriateness and PICC-related complications

We assessed PICC appropriateness at the hospital level, based on whether or not devices placed at the site met all three appropriateness criteria. Data from 52 hospitals were included in the analysis preintervention and postintervention; however, given changes within the collaborating hospitals throughout the study period with some hospitals dropping out of HMS and others joining the collaborative, hospital-level analysis was restricted to 41 hospitals that participated throughout the intervention. Within each hospital, appropriateness assessments were made on the patient level such that overall hospital performance was calculated and shared via the online platform. To control for competing risk, patients who died during the period of review were excluded from the analysis. Complications per PICC were measured at each hospital using standardised definitions and included catheter occlusion, VTE and CLABSI.13 Catheter occlusion was defined as documentation of failure to aspirate, flush the catheter and/or use of tissue plasminogen activator for catheter-related indications.8 VTE was defined as clinically suspected deep vein thrombosis (DVT) and/or pulmonary embolism (PE) not present at the time of PICC placement subsequently confirmed via imaging (ultrasonography or venogram for DVT; CT, high-probability ventilation-perfusion scan or pulmonary angiogram for PE). CLABSI was defined in accordance with the CDC’s National Healthcare Safety Network criteria or if ‘CLABSI’, ‘line bactaeremia’ or, ‘line sepsis’ were documented in the medical record.16 As with appropriateness, rates of complications were shared with hospitals via an online dashboard and quarterly in-person meetings. This report focuses on effectiveness outcomes; the assessment of implementation fidelity, barriers and facilitators is ongoing.

Statistical analysis

We performed two main analyses. First, to evaluate the effect of the intervention on PICC appropriateness and complications, we used change-point analysis and the associated cumulative sum (CUSUM) method as described by Taylor et al.17 18 This approach uses a mean-shift model with CIs obtained through bootstrap analysis so as to provide robust estimation of outcomes in relation to intervention onset. This method was preferable to a Poisson or mixed effects logistic approach because our interest was to identify change points in relation to the intervention, rather than compare means across an a priori assigned time point. Second, to examine the association between appropriateness and complications (composite of occlusion, VTE and CLABSI), we fit multilevel mixed effects logistic regression (accounting for patients nested within hospitals) and mixed effects Poisson models (accounting for rate of events) adjusted for patient-level, device-level and facility-level covariates. Results were expressed as ORs and incidence rate ratios (IRRs) with corresponding 95% CI.

All analyses were performed in Stata, V.16 (Stata, College Station, Texas, USA). A two-sided p<0.05 was considered significant.

Results

From 1 January 2013 to 13 January 2020, data from 41738 PICCs placed in 38 592 unique patients in 52 hospitals were available for analysis. Across hospitals, a majority of patients that received PICCs were men (51.3%), with a median age of 64 years and a median Charlson comorbidity score of 3. The top three indications for PICC insertion were intravenous antibiotics (51.9%), difficult access/need for blood draws (20.3%) and medications requiring central access (11.7%); the indication for insertion was not documented for 3598 (9.3%) PICCs. Among PICCs sampled, 10 953 (28.4%) were placed in ICU settings. Most PICCs were inserted by vascular access teams (n=26 644 (69.0%)), but some were placed by interventional radiologists (n=7171 (18.6%)).

Compared with patients with appropriate PICC use, patients with inappropriate PICC use were younger (63.3 vs 64.5 years), more likely to be black (21.9% vs 18.8%) and women (52.5% vs 43.0%, all p<0.001). With respect to category of appropriateness, 82.1% of PICCs were inappropriate because multilumen PICCs were inserted where a single lumen device would have been sufficient, 29.2% were placed for ≤5 days and 25.9% were placed in patients with CKD (table 1).

Table 1.

Demographic, clinical and device characteristics for all patients that received peripherally inserted central catheters (stratified by PICC appropriateness)

Total
(n=38 592)
Appropriate placement
(n=15 128)
Inappropriate placement
(n=23 464)
P value
Demographics
Age, median (IQR) 64 (52.9–74.8) 64.5 (53.4–75.2) 63.3 (52.1–74.1) <0.001
Women, n (%) 18 809 (48.7%) 6501 (43.0%) 12 308 (52.5%) <0.001
Race, n (%)
White 28 540 (74.0%) 11 466 (75.8%) 17 074 (72.8%) <0.001
Black 7975 (20.7%) 2838 (18.8%) 5137 (21.9%) <0.001
Unknown 799 (2.1%) 280 (1.9%) 519 (2.2%) 0.015
Other 1278 (3.3%) 544 (3.6%) 734 (3.1%) 0.012
Clinical characteristics
Charlson Comorbidity Score, median (IQR) 3 (1–5) 3 (2–5) 3 (1–4) <0.001
Body mass index, median (IQR) 28.8 (24–35.3) 28.9 (24–35.6) 28.7 (24.1–35) 0.111
Comorbidities, n (%)
History of cancer 8593 (22.3%) 2669 (17.6%) 5924 (25.2%) <0.001
History of COPD 9540 (24.7%) 3006 (19.9%) 6534 (27.8%) <0.001
History of CHF 10 001 (25.9%) 2944 (19.5%) 7057 (30.1%) <0.001
History of MI 5813 (15.1%) 1786 (11.8%) 4027 (17.2%) <0.001
History of arthritis 2227 (5.8%) 812 (5.4%) 1415 (6%) 0.006
History of DVT 5244 (13.6%) 1923 (12.7%) 3321 (14.2%) <0.001
History of PE 2704 (7.0%) 940 (6.2%) 1764 (7.5%) <0.001
History of lung disease 15 600 (40.4%) 5048 (33.4%) 10 552 (45%) <0.001
History of severe illness 9962 (25.8%) 1398 (9.2%) 8564 (36.5%) <0.001
History of pneumonia 10 778 (27.9%) 3274 (21.6%) 7504 (32%) <0.001
History of sepsis 16 430 (42.6%) 7263 (48%) 9167 (39.1%) <0.001
History of CVA/TIA 6271 (16.2%) 2051 (13.6%) 4220 (18%) <0.001
History of osteomyelitis 5329 (13.8%) 3753 (24.8%) 1576 (6.7%) <0.001
History of cellulitis 7124 (18.5%) 4467 (29.5%) 2657 (11.3%) <0.001
Cerebrovascular disease 5822 (15.1%) 1926 (12.7%) 3896 (16.6%) <0.001
Dementia 2945 (7.6%) 1109 (7.3%) 1836 (7.8%) 0.074
Diabetes—complicated 8427 (21.8%) 3777 (25%) 4650 (19.8%) <0.001
Diabetes—uncomplicated 7137 (18.5%) 2641 (17.5%) 4496 (19.2%) <0.001
Hypertension 25 931 (67.2%) 10 025 (66.3%) 15 906 (67.8%) 0.002
Mild liver disease 2473 (6.4%) 935 (6.2%) 1538 (6.6%) 0.143
Severe CKD 13 398 (34.7%) 3935 (26%) 9463 (40.3%) <0.001
Peripheral vascular disease 6079 (15.8%) 2669 (17.6%) 3410 (14.5%) <0.001
Active cancer 2568 (6.7%) 513 (3.4%) 2055 (8.8%) <0.001
Laboratory values, median (IQR)
Haemoglobin 10.3 (8.8–11.8) 10.1 (8.6–11.7) 10.6 (9.2–12) <0.001
White blood cell count 9 (6.6–12.3) 9.5 (6.8–13.3) 8.3 (6.4–10.9) 0.377
Platelets (×109 per litre) 237 (170–322) 221 (156–302) 263 (194–352) <0.001
eGFR 61 (54–93) 60 (41–87) 77 (60–101) 0.006
International normalised ratio 1.14 (1.02–1.31) 1.14 (1.03–1.33) 1.14 (1.02–1.3) 0.702
Device characteristics
PICC days, median (IQR) 17 (7–30) 10 (5–28) 30 (15–35) <0.001
Gauge (Fr), median (IQR) 5 (4–5) 5 (5–5) 4 (4–4) <0.001
Number of lumens, n (%)
Single 19 322 (50.1%) 15 128 (100%) 4194 (17.9%) <0.001
Double 15 785 (40.9%) 15 785 (67.3%)
Triple 3483 (9.0%) 3483 (14.8%)
Quadruple 2 (0.0%) 2 (0.0%)
Dwell time ≤5 days, n (%) 6860 (17.8%) 6860 (29.2%)
PICC in patients with CKD, n (%) 6084 (15.8%) 6084 (25.9%)
Indications for PICCs, n (%)
Antibiotics 20 048 (51.9%) 12 342 (81.6%) 7706 (32.8%) <0.001
Blood transfusion or blood products 179 (0.5%) 14 (0.1%) 165 (0.7%) <0.001
Chemotherapy 1270 (3.3%) 129 (0.9%) 1141 (4.9%) <0.001
Difficult access/blood draws 7844 (20.3%) 1292 (8.5%) 6552 (27.9%) <0.001
Medications requiring central access 4533 (11.7%) 731 (4.8%) 3802 (16.2%) <0.001
Multiple incompatible fluids 803 (2.1%) 26 (0.2%) 777 (3.3%) <0.001
Parenteral nutrition 2691 (7%) 190 (1.3%) 2501 (10.7%) <0.001
Medication requiring central access per hospital policy 98 (0.3%) 9 (0.1%) 89 (0.4%) <0.001
Unknown 3598 (9.3%) 884 (5.8%) 2714 (11.6%) <0.001
ICU setting, N (%) 10 953 (28.4%) 852 (5.6%) 10 101 (43%) <0.002
Operator/Inserter, N (%)
Vascular access team 26 644 (69.0%) 10 666 (70.5%) 15 978 (68.1%) <0.001
Interventional Radiology 7171 (18.6%) 2679 (17.7%) 4492 (19.1%) <0.001
Site-level characteristics
Bed size, median (IQR) 380 (273–584) 391 (283–632) 379 (250–537) <0.001
Total number of discharges, median (IQR) 19 591 (12 453–29763) 19 591 (13 245–29763) 19 307 (10 873–29763) <0.001
Teaching hospital, % 37 367 (96.8%) 14 471 (95.7%) 22 896 (97.6%) <0.001
Non-profit, % 31 401 (81.4%) 12 479 (82.5%) 18 922 (80.6%) <0.001
For-profit, % 2381 (6.2%) 1069 (7.1%) 1312 (5.6%) <0.001
Government, % 3137 (8.1%) 796 (5.3%) 2341 (10.0%) <0.001

BMI, body mass index; CHF, congestive heart failure; CKD, chronic kidney disease; CLABSI, central line-associated bloodstream infection; COPD, Chronic Obstructive Pulmonary Disease; CVA/TIA, cerebrovascular accident/transient ischaemic attack; CVC, central venous catheter; DVT, deep vein thrombosis; eGFR, estimated glomerular filtration rate; IBS, irritable bowel syndrome; ICU, intensive care unit; MI, Myocardial Infarction; PE, pulmonary embolism; PICC, peripherally inserted central catheter.

Preintervention appropriateness and frequency of complications

In the preintervention period, most PICCs placed were double-lumen devices (n=10 156, 46.0%), followed by single-lumen (n=9354, 42.4%) and triple-lumen catheters (n=2571, 11.6%). The median duration of PICC use across hospitals was 13.5 days (range: 8–56.5 days).

In the preintervention period, the baseline frequency of inappropriate PICC use (composite of <5 days, multilumen use or PICC use in patients with CKD) was 68.1% (31.8%–96.3% across hospitals). The proportion of PICCs that were inappropriate varied as follows: dwell time ≤5 days 20.9% (5.4%–36.0% across hospitals); multilumen catheters 57.6% (7.1%–93.9% across hospitals) and use in CKD 17.3% (0.2%–28.9% across hospitals).

The baseline frequency of complications was 14.7% (median 2.0%–31.0% across hospitals). The frequency of catheter occlusion was 10.6% (0.5%–27.0% across hospitals), CLABSI 1.8% (0.0%–5.2% across hospitals) and VTE 3.3% (0.0%–8.5% across hospitals).

Postintervention appropriateness and frequency of complications

Following implementation, inappropriate PICC use decreased from 68.1% to 51.0% (absolute reduction=17%, p<0.001; range of absolute decrease 17.3%–80.5% across hospitals). Overall, improvement in appropriateness ranged from −5.2% (one hospital) to +70.3% across 41 hospitals (figure 1). Use of multilumen devices improved the most, decreasing from 57.6% preintervention to 39.6% postintervention (absolute reduction=18%, p<0.001; range of absolute decrease 3.8%–74.4% across hospitals). Similarly, for PICC dwell ≤5 days, improvement from 20.9% preintervention to 13.6% postintervention was observed (absolute reduction=7.3%, p<0.001; range of absolute decrease 3.6%–27.3% across hospitals). For PICC use in CKD, appropriateness improved from 17.3% preintervention to 13.7% postintervention (absolute reduction=3.6%, range of absolute improvement 0.0%–29.0% across hospitals, p<0.001).

Figure 1.

Figure 1

Bar graph illustrating per cent of PICCs meeting all 3 Appropriateness Criteria in 41 Michigan Hospitals (preintervention vs postintervention). PICC, peripherally inserted central catheter.

During the study, PICC-related complications decreased from 14.7% to 10.7% (p=0.001, 0.0%–26.6% across hospitals postintervention). Across hospitals, reductions in complication events preintervention versus postintervention ranged from −15.4% to +9.2% (figure 2). Catheter occlusion improved the most, decreasing from 10.6% to 7.4% (p<0.001, 0.0% to 25.0% across hospitals). Similarly, VTE decreased from 3.3% to 2.5% (p<0.001, 0.0% to 8.7% across hospitals). Specifically, upper-extremity DVT decreased from 2.0% to 1.4% (p<0.001, –1.3% to 3.9% across hospitals). CLABSI decreased from 1.8% to 1.4% (p=0.015, 0.0% to 4.1% across hospitals).

Figure 2.

Figure 2

Bar graph illustrating per cent of PICCs with complications in 41 Michigan Hospitals (preintervention vs postintervention). PICC, peripherally inserted central catheter.

Association between intervention and outcomes

Using CUSUM, change points were identified at February 14, 2017 (95% CI (14 January 2017 to 17 March 2017)) for appropriateness and 15 May 2017 (95% CI (3 January 2017 to 28 March 2017)) for PICC-associated complications. For both change points, the bootstrapped estimates were smaller than the original CUSUM estimate >99% of the time, providing strong evidence that rates of appropriateness and complications changed during this period (online supplemental figure).

Supplementary data

bmjqs-2021-013015supp001.pdf (94.1KB, pdf)

Association between appropriateness and complications

Following adjustment, compared with patients with inappropriate PICC placement, appropriate PICC use was associated with a significantly lower odds of major complications (OR 0.29, 95% CI 0.25 to 0.34). Reductions were observed for all major complications, including catheter occlusion (OR 0.25, 95% CI 0.21 to 0.29), CLABSI (OR 0.61, 95% CI 0.46 to 0.81), VTE (OR 0.40, 95% CI 0.33 to 0.47) and upper-extremity DVT (OR 0.40, 95% CI 0.32 to 0.49, all p<0.001) (table 2). Greater PICC appropriateness was associated with fewer complications (OR 0.72, 95% CI 0.60 to 0.86; Pearson correlation=−0.26, p<0.001 for both). In a Poisson model examining association between appropriateness and complications, patients with appropriate PICC placement experienced a lower rate of major complications than those with inappropriate PICCs (IRR 0.987, 95% CI 0.98 to 0.99, p<0.001).

Table 2.

Association between catheter appropriateness and risk of complications

Appropriate PICC placement (n=15 128), no. (%) Inappropriate PICC placement (n=23 464), no. (%) OR (95% CI) P value
Occlusion 572 3.78% 2998 12.78% 0.25 (0.21 to 0.29) <0.001
CLABSI 136 0.90% 490 2.09% 0.61 (0.46 to 0.81) 0.001
VTE 214 1.41% 925 3.94% 0.40 (0.33 to 0.47) <0.001
All complications 884 5.84% 4130 17.60% 0.29 (0.25 to 0.34) <0.001

Mixed-effects logistic model including hospital random effects and year fixed effects. All models control for patient characteristics (sex, age, Charlson Comorbidity Score, BMI, history of cancer, indication of current CVC at time of PICC placement, line duration).

BMI, body mass index; CLABSI, central line-associated bloodstream infection; CVC, central venous catheter; PICC, peripherally inserted central catheter; VTE, venous thromboembolism.

Discussion

In this multicentre quasiexperimental interventional study, MAGIC implementation in 52 Michigan hospitals was associated with improved PICC appropriateness. Moreover, compared with inappropriate PICC use, appropriate PICC use was associated with a reduction in major complications (OR 0.29, 95% CI 0.25 to 0.34; IRR 0.987, 95% CI 0.98 to 0.99, p<0.001). Given the large number of included hospitals and reduction in the incidence of costly, morbid and potentially lethal complications, broader use of MAGIC in hospitals appears warranted.

Appropriateness criteria have been in use since the 1970s and have traditionally focused on providing guidance on best practices when evidence is unclear or uncertain. These criteria have also been used by policymakers to assess quality of care, inform financial reimbursement and payment and assess the value of services provided to patients. Few appropriateness-based criteria, however, have moved from a theoretical realm (ie, what should be done) to daily clinical practice (ie, what is done). A notable exception is the American College of Radiology Appropriateness Criteria guidance, which has translated recommendations into computerised decision support at the point-of-care using a designated platform (ACR Select).19 At inception, MAGIC was created using a similar approach: recommendations such as limiting the number of lumens or not placing PICCs in patients with CKD are meaningful and accessible to ordering providers. Importantly, while ACR and other appropriateness criteria have focused primarily on reducing healthcare costs, MAGIC also aimed at preventing complications. The recommendation to avoid short-term PICC use is a prime example as alternative, lower risk devices, may be used for this period.

While limited, data showing that MAGIC can be used to assess appropriateness and improve practice are promising and growing. In a study by Swaminathan et al, MAGIC implementation using a combination of education and feedback at a single site reduced PICC complications compared with control sites.10 In a study by investigators in Ontario, applying MAGIC to measure appropriateness of catheter use in a provincial database was found to be feasible with a substantial proportion of PICCs deemed either uncertain or inappropriate—suggesting room for improving quality of care.20 Similarly, a national study of Medicare recipients found that the publication of MAGIC was associated with reductions in overall PICC use in the US.21 The present study advances these findings by showing a significant association between PICC appropriateness and complications across multiple hospitals. In addition, the structured MAGIC implementation yielded significant increase in appropriateness of PICC use and a contemporaneous decrease in complications.10 22 Moreover, using our current data, a ‘back of the envelope’ estimate on potential financial impact suggests substantial savings may be realised as a result of MAGIC. Assuming costs of $145 for catheter occlusion, $15 000 per episode of VTE and $12 000 for CLABSI, we estimated savings of $2.9 million from prevention of complications and an estimated $231 675 savings on average for an individual hospital.8 13 23 Notably, the degree of improvement at individual hospitals was variable with some experiencing dramatic change and others, less so. To gain a greater understanding of which aspects of implementation (eg, the quality of the delivery of the intervention at each site, use of ordersets versus clinical champions and programme differentiation) contributed to our findings, a combination of site visits and qualitative work is ongoing. We anticipate that these qualitative aspects will lend greater insight into what works, what doesn’t and why for hospitals interested in implementing MAGIC.

Our study has limitations. First, given the quality improvement nature of the work, we used an observational study design without a control group. Thus, secular trends or unmeasured confounding may influence our findings. However, to counteract this aspect, we used rigorous analysis including assessment of temporarily of change in relation to introduction of the intervention for confirmation. Second, although models were fully adjusted and we used multiple analyses that included hospital and patient characteristics, our data can only show association—not causation between PICC appropriateness and major complications. Third, patients were included from select hospitals in Michigan that agreed to participate in our initiative and received financial compensation for the same. Given the size of our intervention and inclusion of multiple hospitals (representing close to 80% of all hospital beds in Michigan), we have no reason to believe that this would introduce systematic bias in patient outcomes. However, it is possible that hospital engagement and pay for performance amplified the impact of our intervention. As our interventions targeted process issues such as number of lumens and dwell time, payments were relatively small and the included hospitals represent the majority of all acute care settings in the State of Michigan, we believe our findings are generalisable. Finally, we do not know which of our intervention components was the ‘active ingredient(s)’ in achieving our results; however, qualitative work to better understand this aspect is ongoing.

Our study also has important strengths. To our knowledge, this is the first study showing that implementing MAGIC can lead to both improved catheter appropriateness and patient outcomes. Our findings also suggest that reduction in PICC complications across sites may have substantial economic implications for hospitals, with estimated savings from reduced complications potentially summing to over US$8M8 23–25 In an era of publicly reported measures and resource limitations, the business case to turn to MAGIC as a platform to improving safety and reducing costs in vascular access is therefore compelling. Second, the implementation toolkit used to deploy MAGIC is online and available to the public; it can thus be used by other hospitals, creating a novel and timely resource to improve PICC safety beyond this work.15 Third, because implementation was associated with reduction in costly complications such as VTE and CLABSI, our findings have substantial quality and safety implications for hospitals struggling with these two events. Finally, we used robust methods to validate our findings including those focused on temporality of outcomes related to the intervention and mixed models taking into account clinically relevant confounders. This rigour gives us confidence that our findings are replicable outside our collaborative, especially if the impetus to improve vascular device outcomes in a given hospital is substantial.

In conclusion, our intervention based on MAGIC led to improved PICC appropriateness and reduced patient harm across thousands of patients. Wider use and adoption of MAGIC as a resource to measure, evaluate and improve PICC safety appears warranted.

Footnotes

Twitter: @vineet_chopra

Contributors: All authors contributed to the study design, data analysis and interpretation and manuscript drafting and revision.

Funding: Blue Cross/Blue Shield of Michigan and Blue Care Network supported data collection at each participating site and funded the data coordinating centre but had no role in study concept, interpretation of findings or in the preparation, final approval or decision to submit the manuscript.

Provenance and peer review: Not commissioned; externally peer reviewed.

Supplemental material: This content has been supplied by the author(s). It has not been vetted by BMJ Publishing Group Limited (BMJ) and may not have been peer-reviewed. Any opinions or recommendations discussed are solely those of the author(s) and are not endorsed by BMJ. BMJ disclaims all liability and responsibility arising from any reliance placed on the content. Where the content includes any translated material, BMJ does not warrant the accuracy and reliability of the translations (including but not limited to local regulations, clinical guidelines, terminology, drug names and drug dosages), and is not responsible for any error and/or omissions arising from translation and adaptation or otherwise.

Data availability statement

Given the quality improvement nature, data collected for the study will not be made available to others. However, our online toolkit is available to the public at https://www.improvepicc.com/implementation.html. More details can be found at https://mi-hms.org/quality-initiatives/peripherally-inserted-central-catheter-picc-use-initiative.

Ethics statements

Patient consent for publication

Not required.

Ethics approval

As the purpose of this state-wide collaborative is to measure and improve the quality of existing care practices, this study was assigned a 'not regulated' status.

References

  • 1. Climo M, Diekema D, Warren DK, et al. Prevalence of the use of central venous access devices within and outside of the intensive care unit: results of a survey among hospitals in the prevention epicenter program of the centers for disease control and prevention. Infect Control Hosp Epidemiol 2003;24:942–5. 10.1086/502163 [DOI] [PubMed] [Google Scholar]
  • 2. Meyer BM. Developing an alternative workflow model for peripherally inserted central catheter placement. J Infus Nurs 2012;35:34–42. 10.1097/NAN.0b013e31823bc8fd [DOI] [PubMed] [Google Scholar]
  • 3. Chopra V, Anand S, Hickner A, et al. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis. Lancet 2013;382:311–25. 10.1016/S0140-6736(13)60592-9 [DOI] [PubMed] [Google Scholar]
  • 4. Ajenjo MC, Morley JC, Russo AJ, et al. Peripherally inserted central venous catheter-associated bloodstream infections in hospitalized adult patients. Infect Control Hosp Epidemiol 2011;32:125–30. 10.1086/657942 [DOI] [PubMed] [Google Scholar]
  • 5. Chopra V, Flanders SA, Saint S. The problem with peripherally inserted central catheters. JAMA 2012;308:1527–8. 10.1001/jama.2012.12704 [DOI] [PubMed] [Google Scholar]
  • 6. Greene MT, Flanders SA, Woller SC, et al. The association between PICC use and venous thromboembolism in upper and lower extremities. Am J Med 2015;128:986–93. 10.1016/j.amjmed.2015.03.028 [DOI] [PubMed] [Google Scholar]
  • 7. Chopra V, Smith S, Swaminathan L, et al. Variations in peripherally inserted central catheter use and outcomes in Michigan hospitals. JAMA Intern Med 2016;176:548–51. 10.1001/jamainternmed.2015.8402 [DOI] [PubMed] [Google Scholar]
  • 8. Smith SN, Moureau N, Vaughn VM, et al. Patterns and predictors of peripherally inserted central catheter occlusion: the 3P-O study. J Vasc Interv Radiol 2017;28:749–56. 10.1016/j.jvir.2017.02.005 [DOI] [PubMed] [Google Scholar]
  • 9. Chopra V, Flanders SA, Saint S, et al. The Michigan appropriateness guide for intravenous catheters (magic): results from a Multispecialty panel using the RAND/UCLA appropriateness method. Ann Intern Med 2015;163:S1–40. 10.7326/M15-0744 [DOI] [PubMed] [Google Scholar]
  • 10. Swaminathan L, Flanders S, Rogers M, et al. Improving PICC use and outcomes in hospitalised patients: an interrupted time series study using magic criteria. BMJ Qual Saf 2018;27:271–8. 10.1136/bmjqs-2017-007342 [DOI] [PubMed] [Google Scholar]
  • 11. Michigan Hospital Medicine Safety Consortium . Peripherally inserted central catheter initiative, 2020. Available: https://mi-hms.org/quality-initiatives/peripherally-inserted-central-catheter-picc-use-initiative
  • 12. Chopra V, Kaatz S, Conlon A, et al. The Michigan risk score to predict peripherally inserted central catheter-associated thrombosis. J Thromb Haemost 2017;15:1951–62. 10.1111/jth.13794 [DOI] [PubMed] [Google Scholar]
  • 13. Herc E, Patel P, Washer LL, et al. A model to predict Central-Line-Associated bloodstream infection among patients with peripherally inserted central catheters: the MPC score. Infect Control Hosp Epidemiol 2017;38:1155–66. 10.1017/ice.2017.167 [DOI] [PubMed] [Google Scholar]
  • 14. Landes SJ, McBain SA, Curran GM. An introduction to effectiveness-implementation hybrid designs. Psychiatry Res 2019;280:112513. 10.1016/j.psychres.2019.112513 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Peripherally inserted central catheter (PICC) quality improvement toolkit, 2021. Michigan Hospital medicine safety Consortium. Available: https://www.improvepicc.com/implementation.html [Accessed 25 Feb 2021].
  • 16. Bloodstream infection event (central line-associated BloodstreamInfection and non-central line-associated bloodstream infection). CDC bloodstream infection/device associated infection module, 2020. Available: https://www.cdc.gov/nhsn/pdfs/pscmanual/4psc_clabscurrent.pdf
  • 17. Taylor WA. Change-Point analysis: a powerful new tool for detecting changes, 2010. Available: https://variation.com/wp-content/uploads/change-point-analyzer/change-point-analysis-a-powerful-new-tool-for-detecting-changes.pdf
  • 18. Aylin P, Best N, Bottle A, et al. Following Shipman: a pilot system for monitoring mortality rates in primary care. Lancet 2003;362:485–91. 10.1016/S0140-6736(03)14077-9 [DOI] [PubMed] [Google Scholar]
  • 19. American College of Radiology ACR Appropriateness Criteria® . Radiologic management of central venous access, 2020. Available: https://acsearch.acr.org/docs/3094281/Narrative/
  • 20. Verma AA, Kumachev A, Shah S, et al. Appropriateness of peripherally inserted central catheter use among general medical inpatients: an observational study using routinely collected data. BMJ Qual Saf 2020;29:905–11. 10.1136/bmjqs-2019-010463 [DOI] [PubMed] [Google Scholar]
  • 21. Lindquester WS, Dhangana R, Warhadpande S, et al. Effects of the magic guidelines on PICC placement volume: advanced practice provider and physician trends amongst Medicare beneficiaries from 2010-2018. AJR Am J Roentgenol 2020. 10.2214/AJR.20.23704. [Epub ahead of print: 26 Aug 2020]. [DOI] [PubMed] [Google Scholar]
  • 22. Rogers M, Flanders S, McLaughlin E. Applying magic to improve PICC appropriateness in 42 Michigan hospitals. Abstract published at hospital medicine 2019, March 24-27, National harbor, MD. Abstract 10. Available: https://shmabstracts.org/abstract/applying-magic-to-improve-picc-appropriateness-in-42-michigan-hospitals/
  • 23. Evans RS, Sharp JH, Linford LH, et al. Reduction of peripherally inserted central catheter-associated DVT. Chest 2013;143:627–33. 10.1378/chest.12-0923 [DOI] [PubMed] [Google Scholar]
  • 24. Warren DK, Quadir WW, Hollenbeak CS, et al. Attributable cost of catheter-associated bloodstream infections among intensive care patients in a nonteaching Hospital. Crit Care Med 2006;34:2084–9. 10.1097/01.CCM.0000227648.15804.2D [DOI] [PubMed] [Google Scholar]
  • 25. Al-Rawajfah OM, Hewitt JB, Stetzer F, et al. Length of stay and charges associated with health care-acquired bloodstream infections. Am J Infect Control 2012;40:227–32. 10.1016/j.ajic.2011.03.014 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary data

bmjqs-2021-013015supp001.pdf (94.1KB, pdf)

Data Availability Statement

Given the quality improvement nature, data collected for the study will not be made available to others. However, our online toolkit is available to the public at https://www.improvepicc.com/implementation.html. More details can be found at https://mi-hms.org/quality-initiatives/peripherally-inserted-central-catheter-picc-use-initiative.