Skip to main content
Genes logoLink to Genes
. 2022 Feb 10;13(2):328. doi: 10.3390/genes13020328

Considerations and Suggestions for the Reliable Analysis of miRNA in Plasma Using qRT-PCR

Eunmi Ban 1, Eun Joo Song 1,*
Editors: Giuseppe Iacomino1, Fabio Lauria1
PMCID: PMC8872398  PMID: 35205372

Abstract

MicroRNAs (miRNAs) are promising molecules that can regulate gene expression, and their expression level and type have been associated with early diagnosis, targeted therapy, and prognosis of various diseases. Therefore, analysis of miRNA in the plasma or serum is useful for the discovery of biomarkers and the diagnosis of implicated diseases to achieve potentially unprecedented progress in early treatment. Numerous methods to improve sensitivity have recently been proposed and confirmed to be valuable in miRNA detection. Specifically, quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is an effective and common method for sensitive and specific analysis of miRNA from biological fluids, such as plasma or serum. Despite this, the application of qRT-PCR is limited, as it can be affected by various contaminants. Therefore, extraction studies have been frequently conducted to maximize the extracted miRNA amount while simultaneously minimizing contaminants. Moreover, studies have evaluated extraction efficiency and normalization of the extracted sample. However, variability in results among laboratories still exists. In this review, we aimed to summarize the factors influencing the qualification and quantification of miRNAs in the plasma using qRT-PCR. Factors influencing reliable analysis of miRNA using qRT-PCR are described in detail. Additionally, we aimed to describe the importance of evaluating extraction and normalization for reliable miRNA analysis and to explore how miRNA detection accuracy, especially from plasma, can be improved.

Keywords: qRT-PCR, plasma, miRNA, amplification efficiency

1. Introduction

Circulating microRNAs (miRNAs) are highly stable extracellular molecules that circulate in the bloodstream [1,2]. These circulating miRNAs are approximately 22 nucleotides in length and play an important role in gene regulation by binding to and repressing the activity of specific target messenger RNAs (mRNAs). Profiles of miRNAs in plasma and serum have been found to be altered in cancer and other disease states [3,4]. Numerous studies have reported that specific miRNA expression profiles are associated with pathological conditions such as cardiovascular disease [5], cancer [6] and other diseases [7], which may provide diagnostic and therapeutic value as biomarkers. In previous studies, elevated plasma expression levels of miRNA-499 [8], miRNA-122 [9] and miRNA-155 [10] are known to be associated with AMI, liver injury, and inflammation, respectively. Meanwhile, the plasma expression levels of miRNA-34 [11] and miRNA-23a [12] are known to decrease in solid tumors and lung cancer, respectively.

Therefore, analyses of circulating miRNAs are important for the discovery and study of disease biomarkers that may aid in disease risk assessment, diagnosis, prognosis, and monitoring of treatment responses (Figure 1).

Figure 1.

Figure 1

The number of PubMed search results regarding articles reporting on analyses of circulating miRNAs.

Currently, miRNA levels in biological fluids, tissues, and cells are measured after extraction by commercial RNA extraction kits, such as chloroform–phenol-based extraction [13,14], magnetic bead extraction [15], and column-based extraction [16], followed by microarray [17,18], Northern blotting [19,20], and quantitative reverse-transcription polymerase chain reaction (qRT-PCR) analysis [21,22]. Among these methods, qRT-PCR is widely preferred over other detection methods because of its high sensitivity and specificity for detecting low levels of circulating miRNAs in plasma and serum (Figure 2).

Figure 2.

Figure 2

Methods for endogenous miRNA analysis in plasma or serum compared in terms of the proportions of articles reporting their use among PubMed search results from the past 10 years.

However, in previous studies, plasma miRNA levels have varied according to the laboratories performing the measurements [23,24]. This can mainly be due to differences in sample processing, measurements and data analysis [25,26,27,28]. In general, accurate miRNA measurement using qRT-PCR requires a high-quality sample, especially because of the low concentration of miRNA in plasma. Therefore, to increase the extraction efficiency and consistency of miRNAs analysis obtained from plasma and serum, numerous efforts over several years have focused on various highly sensitive and specific methods of miRNA extraction from plasma [29,30,31]. Additionally, similar efforts targeting data normalization [32,33] and the optimization and assessment of PCR conditions have been pursued to improve the accuracy of PCR measurements [34,35]. However, few reviews have focused on the importance and necessity of evaluating PCR conditions for optimizing extraction conditions.

In this review, which focuses on quantity and quality, we describe factors influencing miRNA measurement in plasma and serum using qRT-PCR. Additionally, we review the advantages of assessing PCR efficiency and normalization to obtain reliable and accurate PCR-based results of miRNA analysis in plasma. This evaluation calls attention to the importance of the assessment of PCR efficiency for optimizing PCR and miRNA extraction conditions.

2. Inconsistent Measurement of miRNA Extracted in Plasma Using qRT-PCR

Since miRNA analysis using qRT-PCR greatly depends on the quality of the miRNA extract, the results of miRNA analysis are different depending on the sampling procedure applied to the same sample. Many researchers have reported this inconsistency in miRNA analysis results, and various efforts are being made to analyze the factors that cause analysis inconsistency during the sample extraction step [31,36,37,38]. Brunet-Vega et al. compared the Cq levels of miRNAs extracted from the same plasma samples using five commercially available miRNA extraction kits [37]. They reported that the levels of the tested miRNAs were similar, but the levels of the spiked-in exogenous miRNAs were different. For this reason, the analyzed endogenous miRNAs were measured differently from the spike-in exogenous miRNAs. Another research group presented differences in the recovery and levels of miRNAs tested using two different miRNA extraction processes [31]. They also showed that the levels of tested miRNAs were affected by various sample treatments during the sample extraction process. Poel et al. also presented the effect of different carriers and pretreatment times on miRNA extraction recovery and showed inconsistent results between studies [38]. These studies recommended the need for standardization of protocols, including sample handling and extraction processes, to reduce the mismatch results of miRNAs in plasma between laboratories and between assays to perform reliable biomarker screening and discovery of miRNAs in plasma samples.

3. Factors Inhibiting Accurate miRNA Measurement in Plasma Using qRT-PCR

miRNA levels in plasma are low—10- and 100-times less than the concentrations in cells and tissues, respectively [39]. Therefore, the reliable and accurate analysis of miRNAs in plasma is a major issue, despite significant developments in the field. Among various analytical methods, qRT-PCR is usually used to analyze circulating miRNA levels in biological fluids, including plasma and serum, owing to its high specificity. However, qRT-PCR analysis can be compromised by various materials, such as matrix and extraction residual reagents in samples, and consequently, miRNA analysis results can vary depending on the purity of the extracted sample. Specifically, the effect of the interference on miRNA analysis in plasma is larger in cells and tissues because of the low abundance of miRNAs in plasma. Therefore, many studies have investigated the interference of miRNA analysis in plasma using qRT-PCR, which is primarily caused by sample components and the residual reagents extracted [36,40].

3.1. Sample Matrix

It is established that interference of qRT-PCR analysis is caused by various components present within the sample matrix. Therefore, for reliable qRT-PCR analysis, a high-purity sample from which components, such as proteins, lipids, and carbohydrates have been removed, must be prepared. The abundance of these confounding components varies significantly according to dietary status, anticoagulant type, as well as sampling and storage conditions [41,42]. Besides matrix components, hemolysis can be a major cause of variation in miRNA levels. Several miRNAs are found in large amounts in red blood cells (RBCs), and they are released from RBCs as a result of hemolysis, thereby increasing the level of certain miRNAs in the blood. However, hemolysis is more difficult to control than other conditions because it occurs frequently during blood sampling. Many authors have reported that miRNA qRT-PCR analysis results differ according to the degree of hemolysis of the sample. Myklebust et al. showed that qRT-PCR miRNA measurement is influenced by hemolysis [43]; in their study, the plasma miRNA concentration increased as the hemolyzed proportion of the sample increased, but the degree of increase depended on the miRNA type. Specifically, miR-16 is one of the most abundant miRNAs in RBCs [44], and many studies have shown that hemolysis may increase miR-16 levels in plasma. This is especially important because, due to its high abundance relative to other miRNAs, miRNA-16 is used as an endogenous reference gene to normalize the data after qRT-PCR analysis. Thus, hemolysis must be taken into consideration for accurate screening of blood miRNA levels. Feng et al. also demonstrated the effect of the sample matrix on miRNA analysis using qRT-PCR [36]. They showed variability in miRNA levels among matrices with varying compositions, including in terms of types or levels of anticoagulant molecules, plasma protein, and lipids, and hemolysis was analyzed using qRT-PCR. The authors showed that the factors influencing the sample matrix (leading to variability in miRNA analysis in plasma using qRT-PCR) are primarily associated with dietary status, anticoagulant selection, and plasma sample storage conditions. Mompeón et al. also demonstrated the effect of hemolysis on miRNA analysis using qRT-PCR, observing that miRNA levels differed between serum and plasma [45]. In addition to differences in sample components and conditions, there may be differences in the degree of interference with qRT-PCR analysis due to extraction efficiency. Variations in analysis results may also be associated with the purity of the prepared sample, which depends on the sample extraction method. For this reason, various sample extraction kits and methods have been developed, and some of these have been reported to reduce intralaboratory and interlaboratory variability. Several research groups have presented and compared commercial RNA extraction kits, and studies related to the standardization of miRNA extraction methods from biological fluids have been conducted [46,47,48]. Column-based extraction kits often obtain high-quality miRNA extracts, and they are associated with lower extraction variation chloroform–phenol-based kits. However, chloroform–phenol-based kits, such as Trizol, are also known for favorable extraction recovery and costs.

3.2. Residual Reagents

For reliable qRT-PCR analysis, it is necessary to minimize any interfering factors using an extraction approach. For this reason, different extraction methods have been developed and applied to measure miRNA in cells, plasma, serum, and tissues. Currently, commercial miRNA extraction kits are largely divided into chloroform–phenol-based reagent kits and column-based extraction kits. Both methods include phenol extraction, which is a long-established approach to extracting nucleotides from biological samples. However, with phenol extraction, residual solvents, including phenol, remain in the final purified RNA sample after extraction and interfere with qRT-PCR-based miRNA analysis as a contaminant [49]. Among this interference caused by extraction reagents, residual phenol not only interferes with PCR analysis, but it can also cause errors in the quantification of RNA extracted from plasma. Specifically, the interference by residual phenol on miRNA analysis in plasma or serum is severe (relative to interference in cells and tissues) because of the low abundance of miRNAs in plasma and serum. For this reason, many researchers have investigated the issue of residual phenol. Spectrometric overestimations caused by residual phenol from extracted RNA yields have frequently led to inaccurate and variable plasma miRNA measurements. This problem is exacerbated by the fact that the wavelengths of RNA and phenol are similar, and the level of RNA in plasma is low compared with residual phenol. Several companies have, therefore, developed nanodrop systems to measure residual phenol concentrations in extracted samples to prevent mismeasurement of the amount or concentration of extracted RNAs by spectrometry [50,51]. Additionally, researchers have developed new systems that are not based on absorbance but that use specific fluorescent dyes for small RNAs to reliably measure extracted miRNAs [52,53]. For circulating biomarker detection analysis, accuracy could be optimized via the use of equal volume inputs rather than the same amount of RNA [54]. In plasma miRNA analysis by qRT-PCR, instead of direct RNA measurements, extraction recovery and analyzed samples are evaluated and normalized using spiked exogenous miRNA.

4. Important Considerations for Reliable miRNA Analysis Using qRT-PCR

Plasma miRNA analysis is an important area of biological and clinical research that is gaining increasing recognition. However, low plasma miRNA levels are associated with miRNA measurement errors and consequent inaccurate analyses [32]. These errors are mainly caused by interference in the sample matrix. Therefore, researchers have attempted to evaluate interference and develop normalization methods to minimize errors caused by such interference.

4.1. Amount of miRNA

Given that highly purified samples are needed for successful qRT-PCR analysis, many researchers have concentrated on developing methods that emphasize extracting high-quality RNA rather than high yields. Column-based extraction kits are often used for RNA extraction from various sample types. However, high quantities of RNA are also needed for reliable miRNA analysis, but it is challenging to efficiently extract RNAs from serum and plasma [55]. For this reason, chloroform–phenol-based extraction is still used to extract miRNAs from plasma, although several researchers have discussed the problems associated with chloroform–phenol-based extraction methods in PCR analysis. Various extraction kits have been compared and investigated [53]. In addition to extraction kits, various trials have been conducted, including comparisons between different modifications of extraction processes (such as the addition of carriers to trigger precipitation or the modification of incubation conditions) to increase extraction recovery without loss of quality. Some research teams have optimized carrier types, concentrations, and incubation conditions to maximize plasma miRNA extraction [56,57].

4.2. Normalization

Similar to other analytical methods, qRT-PCR analysis is subject to variations or errors, including in association with elements such as sample handling and volume measurements. Specifically, qRT-PCR plasma miRNA analysis can be greatly influenced by nutritional status, anticoagulant type, and plasma storage conditions. Therefore, normalization is important to mitigate variations in qRT-PCR analysis. One of methods for normalization of miRNA analysis by qRT-PCR is global normalization, which uses the calculated mean of all miRNAs in a given sample as the normalizer. This method is highly recommended when dealing with large scale miRNA expression profiling studies where several hundreds of miRNAs are analyzed [58]. However, global normalization cannot be applied for small-scale studies. Another popular method is normalization through reference genes. U6 is a small nuclear RNA commonly used as an endogenous internal control to normalize miRNA expression levels in different biological samples, including plasma. However, there is evidence that U6 plasma levels vary under certain conditions [59]. Therefore, various studies have been conducted to identify more reliable reference genes for normalizing endogenous plasma miRNA levels [60,61]. However, evaluations of different reported reference genes have yielded inconsistent findings [33,62,63,64]. Consequently, efforts have led to the identification of an appropriate endogenous miRNA for normalization, accounting for differences in plasma according to various factors, including disease status, sex, and age. External references, such as cel-miR-39-1 for normalization, are also frequently used to correct for extraction recovery and measurement. Zhang et al. showed the accuracy of normalization by reference gene candidates using exogenous miRNA (spiked-in cel-miR-39) as a target (Figure 3).

Figure 3.

Figure 3

Effects of normalization by different reference gene methods on the expression levels of miRNAs from plasma samples of stable coronary artery disease patients and healthy controls (n = 5 in each group). For each group, 2 µL of exogenous cel-miR-39 was spiked into 300 µL plasma. The levels of cel-miR-39 were assessed by qRT-PCR and were normalized to miR-16, miR-6090, miR-4516, miR-484, and RNU6 [62].

Such an approach can eliminate multiple deviations of the experimental process, yielding more robust results. However, the approach also makes the experimental procedure cumbersome, and clinical applications more inconvenient. For example, cel-miR-39 was spiked into serum immediately before RNA extraction, allowing for the control of technical variation. However, the cel-miR-39 recovery was variable, ranging from 1% to 56%, thereby demonstrating the inherent need to take technical variability into account when performing absolute quantification [65]. Additionally, extraction kit-dependent differences in isolation yields across exogenous cel-miRs were reported. Nevertheless, the use of an exogenous cel-miR for normalization and correction presents less variability than strategies based on the concentration of endogenous components, such as the frequently used miR-16-5p [66]. Therefore, the normalization or correction strategy and, to a lesser extent, postanalytical concerns strongly limit the clinical implementation of miRNAs. To date, researchers are yet to establish a robust method of miRNA quantification for qRT-PCR that is clinically easy to implement and universally accepted.

4.3. Amplification Efficiency

In each cycle, qRT-PCR automatically detects the PCR amplification of a specific gene target. In PCR analysis, the number of target sequence molecules should double during each replication cycle, corresponding to 100% amplification efficiency. However, in practice, inappropriate reaction conditions and polymerase inhibition affect primer template annealing, resulting in decreased amplification efficiency and potentially leading to inaccurate conclusions. The assessment of factors affecting amplification efficiency provides information regarding inappropriate or suboptimal reaction conditions, as well as the presence of contaminants interfering with accurate qRT-PCR analysis. Therefore, qRT-PCR assays result in significant uncertainty due to variations in amplification and extraction efficiency [67,68]. For these reasons, several studies have investigated amplification efficiency to improve the accuracy and reliability of qRT-PCR analysis [23,37,69,70,71]. Brunet-Vega et al. demonstrated the necessity of exogenous genes through circulating miRNA profiling analysis using a commercial RNA extraction kit and exogenous genes to control for technical factors affecting final miRNA levels. Additionally, the observation that PCR efficiency reduces the variability of miRNAs circulating between samples should be validated because miRNA analysis in plasma using PCR can be affected by samples and PCR components [37]. Lebuhn et al. also demonstrated interlaboratory variation in qRT-PCR miRNA analysis in terms of amplification efficiency according to qRT-PCR-related factors, including interlaboratory differences in extraction steps [23]. Zununi Vahed and our team have successfully optimized extraction conditions through evaluations of amplification efficiency for reliable endogenous miRNA analysis using qRT-PCR [69,70]. Table 1 shows extraction method-dependent differences in amplification efficiency and quantification cycle (Ct) values of extracted miRNA.

Table 1.

Mean quantification cycle (Ct), PCR efficiency, and correlation–coefficient (R2) values of miR-21 isolation from cell lines, urine, and plasma by different methods.

Method Body Fluids Cell Lines Urine Sediments
Ct E (%) R 2 Slope Ct E (%) R2 Slope Ct E (%) R 2 Slope
KCH3COOH 31.1 ± 0.4 103.54 0.995 −3.24 17.5 ± 0.07 99.5 0.992 −3.33 23.0 ± 0.3 100 0.998 −3.32
PEG4000 33.2 ± 1.0 111.5 0.993 −3.074 20.0 ± 0.13 95.49 0.996 −3.44 25.7 ± 0.45 98 1 −3.37
PEG6000 36.8 ± 0.2 91.99 0.977 −3.53 18.3 ± 0.32 116 0.983 −2.99 28.1 ± 0.74 86 0.976 −3.683
LiCl8M 34.8 ± 0.5 94.17 0.982 −3.47 21.8 ± 0.49 100.46 0.97 −3.31 31.7 ± 0.02 108 0.961 −3.145
Ethanol+LiCl 33.3 ± 0.07 99.46 0.994 −3.34 20.9 ± 0.9 105 0.998 −3.189 25.3 ± 0.62 114 0.993 −3.024
Ethanol 35.0 ± 0.09 120.02 0.979 −2.92 22.4 ± 0.03 98.03 0.991 −3.37 37.8 ± 0.63 105 0.982 −3.189

Data from three biological replicates of cell lines (HT-29 and HUVEC), body fluids (plasma), and urine samples. (Reproduced from [69]).

Svec et al. reported on factors associated with effective amplification efficiency [71]. Given that polymerase inhibition is caused by contaminants transferred from the RNA isolation process or sample matrix, for factors related to PCR reaction conditions, extraction conditions should be evaluated and optimized through assessments of amplification efficiency to reduce contaminants interfering with accurate qRT-PCR analysis. These studies have revealed that contaminants have a greater effect on qRT-PCR-based miRNA analysis from plasma than samples such as cells and tissues due to low levels of plasma miRNAs. Therefore, potential sources of interference in extracted plasma samples must be identified and corrected based on amplification efficiency before conducting qRT-PCR analysis. Reaction conditions such as annealing and primer conditions must first be evaluated and optimized in terms of amplification efficiency to ensure accurate analysis. Importantly, based on the evaluation of amplification efficiency, the specificity and sensitivity of qRT-PCR results can differ by primer type and concentration [72].

5. Discussion

Clinical and pharmaceutical research about plasma or serum miRNAs is becoming increasingly important. Consequently, endogenous plasma miRNA analysis has also become critical. Analysis of endogenous plasma miRNA is conducted using qRT-PCR, but such analyses have shown high variability between different laboratories and individuals [24]. One explanation for this is that miRNA levels in plasma are low, and qRT-PCR analysis is consequently affected by extraction and sample components. Therefore, several studies have investigated reproducible techniques and adjustments applied to miRNA analysis, such as sample extraction and normalization techniques. The high sensitivity of qRT-PCR as an analytical tool is matched by its sensitivity to interference by various factors. Therefore, the optimization of an effective extraction method is a major consideration for reliable PCR analysis, and many published articles report on extraction methods to minimize sample interference. Similarly, normalization and optimization of PCR conditions in terms of amplification efficiency have also been investigated, with consideration of issues, such as hemolysis, as major causes of interference. Specifically, normalization is heavily emphasized as an important factor facilitating reliable evaluation of plasma miRNA. Normally, reference genes are used to normalize endogenous miRNA, while exogenous miRNAs, such as cel-39-1, can also be added to samples to compensate for differences in extraction efficiency between samples [37]. However, these do not reflect extraction recovery because extraction efficiency differs between endogenous and exogenous miRNA, as does the effect of amplification efficiency on the environment of the extracted sample. Therefore, in addition to exogenous miRNA, appropriate reference genes are needed to normalize extracted endogenous miRNA levels, and reference gene selection must be prioritized because some reference genes can differ depending on the sample condition and type. With normalization, the evaluation of amplification efficiency is also crucial for the reliability of qRT-PCR studies [37,73,74]. Sreedharan et al. demonstrated improvements in the reliability of expression data through primer-dependent improvements in amplification efficiency [73]. Variations in primer concentration and annealing temperature, as well as primer design, can affect amplification efficiency and consequently affect the reliability of expression data. Optimization of PCR and extraction conditions through assessments of amplification efficiency might be important determinants of accurate and reliable qRT-PCR analysis of endogenous plasma miRNA.

This review describes the considerable variation and poor reproducibility of qRT-PCR-based plasma miRNA analysis associated with incomplete optimization of extraction and RT-PCR conditions through amplification efficiency and normalization. In the context of evaluating amplification, the use of exogenous and endogenous reference genes for normalization is necessary for the reliable and reproducible quantification of circulating miRNAs in plasma. These factors should be considered when translating the analysis of circulating miRNAs from plasma and serum into validated biomarker-based tests for routine clinical use. However, despite advances, such as the standardization of extraction processes and normalization for reliable qRT-PCR analysis of plasma miRNA, issues remain regarding the accuracy of qRT-PCR analysis due to individual differences in matrix composition. Therefore, as shown in Figure 4, we propose that the optimization of extraction conditions and the evaluation and identification of dependable reference genes (based on assessments of amplification efficiency) are necessary to ensure reliable and robust qRT-PCR-based miRNA analysis necessity for future applications of circulating miRNAs.

Figure 4.

Figure 4

Suggested flowchart for qRT-PCR analysis of plasma miRNA.

6. Conclusions

This review presented factors influencing measurements of miRNAs in plasma/serum including assessment of PCR efficiency and normalization to obtain reliable and accurate PCR-based results of miRNA analysis in plasma. It could suggest the necessity of the assessment of PCR efficiency for the optimization of PCR and miRNA extraction conditions. In this review, the effect of factors related to extraction efficiency such as sample matrix, residual solvent after extraction process and RNA amount was described among various factors influencing measurements of miRNAs using qRT-PCR. These factors may cause inhibitors of qRT-PCR analysis and consequently can lead to inaccurate qRT-PCR analysis. The necessity of amplification efficiency and normalization as another considerable part was reported for reliable and reproducible quantification of circulating miRNAs in plasma using qRT-PCR. From this review, we conclude that the optimization of extraction conditions and selection of reliable reference genes based on assessment of the amplification efficiency should be prioritized for achieving a reliable qRT-PCR-based miRNA analysis in plasma/serum.

Author Contributions

Conceptualization, E.B. and E.J.S.; investigation, E.B.; writing—original draft preparation, E.B.; writing—review and editing, E.B. and E.J.S.; supervision, E.J.S.; project administration, E.J.S.; funding acquisition, E.J.S. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by a National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT (2020R1A4A4079494 and 2019R1A2C2004052), as well as a Korea Basic Science Institute (National Research Facilities and Equipment Center) grant funded by the Ministry of Education (2021R1A6C101A442).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Lindner K., Haier J., Wang D.I., Watson D.J., Hussey R. Hummel, Circulating microRNAs: Emerging biomarkers for diagnosis and prog K. nosis in patients with gastrointestinal cancers. Clin. Sci. 2015;28:1–15. doi: 10.1042/CS20140089. [DOI] [PubMed] [Google Scholar]
  • 2.Mitchell P.S., Parkin R.K., Kroh E.M., Fritz B.R., Wyman S.K., Pogosova-Agadjanyan E.L., Peterson A., Noteboom J., O’Briant K.C., Allen A., et al. Circulating microRNAs as stable blood-based markers for cancer detection. Proc. Natl. Acad. Sci. USA. 2008;105:10513–10518. doi: 10.1073/pnas.0804549105. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Kawaguchi T., Komatsu S., Ichikawa D., Tsujiura M., Takeshita H., Hirajima S., Miyamae M., Okajima W., Ohashi T., Imamura T., et al. Circulating MicroRNAs: A Next-Generation Clinical Biomarker for Digestive System Cancers. Int. J. Mol. Sci. 2016;17:1459. doi: 10.3390/ijms17091459. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Liao T.-L., Chen Y.-M., Hsieh C.-W., Chen H.-H., Lee H.-C., Hung W.-T., Tang K.-T., Chen D.-Y. Upregulation of circulating microRNA-134 in adult-onset Still’s disease and its use as potential biomarker. Sci. Rep. 2017;7:4214. doi: 10.1038/s41598-017-04086-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Zhou S.-S., Jin J.-P., Wang J.-Q., Zhang Z.-G., Freedman J.H., Zheng Y., Cai L. miRNAS in cardiovascular diseases: Potential biomarkers, therapeutic targets and challenges. Acta Pharmacol. Sin. 2018;39:1073–1084. doi: 10.1038/aps.2018.30. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Wu Y., Li Q., Zhang R., Dai X., Chen W., Xing D. Circulating microRNAs: Biomarkers of disease. Clin. Chim. Acta. 2021;516:46–54. doi: 10.1016/j.cca.2021.01.008. [DOI] [PubMed] [Google Scholar]
  • 7.Backes C., Meese E., Keller A. Specific miRNA Disease Biomarkers in Blood, Serum and Plasma: Challenges and Prospects. Mol. Diagn. Ther. 2016;20:509–518. doi: 10.1007/s40291-016-0221-4. [DOI] [PubMed] [Google Scholar]
  • 8.Corsten M.F., Dennert R., Jochems S., Kuznetsova T., Devaux Y., Hofstra L., Wagner D.R., Staessen J.A., Heymans S., Schroen B. MicroRNA-208b and MicroRNA-499 Reflect Myocardial Damage in Cardiovascular Disease. Circ. Cardiovasc. Genet. 2010;3:499–506. doi: 10.1161/CIRCGENETICS.110.957415. [DOI] [PubMed] [Google Scholar]
  • 9.Bandiera S., Pfeffer S., Baumert T.F., Zeisel M.B. miR-122—A key factor and therapeutic target in liver disease. J. Hepatol. 2015;62:448–457. doi: 10.1016/j.jhep.2014.10.004. [DOI] [PubMed] [Google Scholar]
  • 10.Mahesh G., Biswas R. MicroRNA-155: A Master Regulator of Inflammation. J. Interferon. Cytokine Res. 2019;39:321–330. doi: 10.1089/jir.2018.0155. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Zhang L., Liao Y., Tang L. MicroRNA-34 family: A potential tumor suppressor and therapeutic candidate in cancer. J. Exp. Clin. Cancer Res. 2019;38:53. doi: 10.1186/s13046-019-1059-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Hetta H.F., Zahran A.M., Shafik E.A., El-Mahdy R.I., Mohamed N.A., Nabil E.E., Esmaeel H.M., Alkady O.A., Elkady A., Mohareb D.A., et al. Circulating miRNA-21 and miRNA-23a Expression Signature as Potential Biomarkers for Early Detection of Non-Small-Cell Lung Cancer. Microrna. 2019;8:206–215. doi: 10.2174/1573399815666190115151500. [DOI] [PubMed] [Google Scholar]
  • 13.Ban E., Chae D.K., Song E.J. Simultaneous detection of multiple microRNAs for expression profiles of microRNAs in lung cancer cell lines by capillary electrophoresis with dual laser-induced fluorescence. J. Chromatogr. A. 2013;1315:195–199. doi: 10.1016/j.chroma.2013.09.048. [DOI] [PubMed] [Google Scholar]
  • 14.Kroh E., Parkin R., Mitchell P., Tewari M. Analysis of circulating microRNA biomarkers in plasma and serum using quantitative reverse transcription-PCR (qRT-PCR) Methods. 2010;50:298–301. doi: 10.1016/j.ymeth.2010.01.032. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Chen S., Shiesh S.C., Lee G.B., Chen C. Two-step magnetic bead-based (2MBB) techniques for immunocapture of extracellular vesicles and quantification of microRNAs for cardiovascular diseases: A pilot study. PLoS ONE. 2020;15:e0229610. doi: 10.1371/journal.pone.0229610. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Guo Y., Vickers K., Xiong Y., Zhao S., Sheng Q., Zhang P., Zhou W., Flynn C.R. Comprehensive evaluation of extracellular small RNA isolation methods from serum in high throughput sequencing. BMC Genom. 2017;18:50. doi: 10.1186/s12864-016-3470-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Zhu W., Su X., Gao X., Dai Z., Zou X. A label-free and PCR-free electrochemical assay for multiplexed microRNA profiles by ligase chain reaction coupling with quantum dots barcodes. Biosens. Bioelectron. 2014;53:414–419. doi: 10.1016/j.bios.2013.10.023. [DOI] [PubMed] [Google Scholar]
  • 18.Oxnard G.R., Paweletz C.P., Kuang Y., Mach S.L., O’Connell A., Messineo M.M., Luke J.J., Butaney M., Kirschmeier P., Jackman D.M., et al. Noninvasive Detection of Response and Resistance in EGFR-Mutant Lung Cancer Using Quantitative Next-Generation Genotyping of Cell-Free Plasma DNA. Clin. Cancer Res. 2014;20:1698–1705. doi: 10.1158/1078-0432.CCR-13-2482. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Pall G.S., Hamilton A.J. Improved northern blot method for enhanced detection of small RNA. Nat. Protoc. 2008;3:1077–1084. doi: 10.1038/nprot.2008.67. [DOI] [PubMed] [Google Scholar]
  • 20.Huang Q., Mao Z., Li S., Hu J., Zhu Y. A non-radioactive method for small RNA detection by northern blotting. Rice. 2014;7:26. doi: 10.1186/s12284-014-0026-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Xia L., Xia W., Li S., Li W., Chu B. Identification and expression of small non-coding RNA, L10-Leader, in different growth phases of Streptococcus mutans. Nucleic Acid Ther. 2012;22:177–186. doi: 10.1089/nat.2011.0339. [DOI] [PubMed] [Google Scholar]
  • 22.Gharbi S., Khateri S., Soroush M.R., Shamsara M., Naeli P., Mowla S.J. MicroRNA expression in serum samples of sulfur mustard veterans as a diagnostic gateway to improve care. PLoS ONE. 2018;13:e0194530. doi: 10.1371/journal.pone.0194530. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lebuhn M., Derenkó J., Rademacher A., Helbig S., Munk B., Pechtl A., Stolze Y., Prowe S., Schwarz W.H., Schlüter A., et al. DNA and RNA Extraction and Quantitative Real-Time PCR-Based Assays for Biogas Biocenoses in an Interlaboratory Comparison. Bioengineering. 2016;3:7. doi: 10.3390/bioengineering3010007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Kloten V., Neumann M.H., Di Pasquale F., Sprenger-Haussels M., Shaffer J.M., Schlumpberger M., Herdean A., Betsou F., Ammerlaan W., Hällström T.A., et al. Multicenter Evaluation of Circulating Plasma MicroRNA Extraction Technologies for the Development of Clinically Feasible Reverse Transcription Quantitative PCR and Next-Generation Sequencing Analytical Work Flows. Clin. Chem. 2019;65:1132–1140. doi: 10.1373/clinchem.2019.303271. [DOI] [PubMed] [Google Scholar]
  • 25.Kuang J., Yan X., Genders A.J., Granata C., Bishop D.J. An overview of technical considerations when using quantitative real-time PCR analysis of gene expression in human exercise research. PLoS ONE. 2016;13:e0196438. doi: 10.1371/journal.pone.0196438. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Iguchi T., Niino N., Tamai S., Sakurai K., Mori K. Absolute Quantification of Plasma MicroRNA Levels in Cynomolgus Monkeys, Using Quantitative Real-time Reverse Transcription PCR. J. Vis. Exp. 2018;132:e56850. doi: 10.3791/56850. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Binderup H.G., Madsen J.S., Heegaard N.H.H., Houlind K., Andersen R.F., Brasen C.L. Quantification of microRNA levels in plasma—Impact of preanalytical and analytical conditions. PLoS ONE. 2018;13:e0201069. doi: 10.1371/journal.pone.0201069. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Parker V.L., Cushen B.F., Gavriil E., Marshall B., Waite S., Pacey A., Heath P.R. Comparison and optimisation of microRNA extraction from the plasma of healthy pregnant women. Mol. Med. Rep. 2021;23:258. doi: 10.3892/mmr.2021.11897. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Androvic P., Romanyuk N., Urdzikova-Machova L., Rohlova E., Kubista M., Valihrach L. Two-tailed RT-qPCR panel for quality control of circulating microRNA studies. Sci. Rep. 2019;9:4255. doi: 10.1038/s41598-019-40513-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Liu K., Tong H., Li T., Wang X., Chen Y. Research progress in molecular biology related quantitative methods of MicroRNA. Am. J. Transl. Res. 2020;12:3198–3321. [PMC free article] [PubMed] [Google Scholar]
  • 31.Fauth M., Hegewald A.B., Schmitz L., Krone D.J., Saul M.J. Validation of extracellular miRNA quantification in blood samples using RT-qPCR. FASEB BioAdvances. 2019;1:481–492. doi: 10.1096/fba.2019-00018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Gevaert A.B., Witvrouwen L., Vrints C.J., Heidbuchel H., Van Craenenbroeck E.M., Van Laere S.J. MicroRNA profiling in plasma samples using qPCR arrays: Recommendations for correct analysis and interpretation. PLoS ONE. 2018;13:e0193173. doi: 10.1371/journal.pone.0193173. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Faraldi M., Gomarasca M., Sansoni V., Perego S., Banf G., Lombardi G. Normalization strategies differently affect circulating miRNA profile associated with the training status. Sci. Rep. 2019;9:1584. doi: 10.1038/s41598-019-38505-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Mei Q., Li X., Meng Y., Wu Z., Guo M., Zhao Y., Fu X., Han W. A Facile and Specific Assay for Quantifying MicroRNA by an Optimized RT-qPCR Approach. PLoS ONE. 2012;7:e46890. doi: 10.1371/journal.pone.0046890. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Stein E.V., Duewer D.L., Farkas N., Romsos E.L., Wang L., Cole K.D. Steps to achieve quantitative measurements of microRNA using two step droplet digital PCR. PLoS ONE. 2017;12:e0188085. doi: 10.1371/journal.pone.0188085. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Feng X., Liu Y., Wan N. Plasma microRNA detection standardization test. J. Clin. Lab. Anal. 2020;34:e23058. doi: 10.1002/jcla.23058. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Brunet-Vega A., Pericay C., Quílez M.E., Ramírez-Lázaro M.J., Calvet X., Lario S. Variability in microRNA recovery from plasma: Comparison of five commercial kits. Anal. Biochem. 2015;488:28–35. doi: 10.1016/j.ab.2015.07.018. [DOI] [PubMed] [Google Scholar]
  • 38.Poel D., Buffart T.E., Oosterling-Jansen J., Verheul H.M., Voortman J. Evaluation of several methodological challenges in circulating miRNA qPCR studies in patients with head and neck cancer. Exp. Mol. Med. 2018;50:e454. doi: 10.1038/emm.2017.288. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Pritchard C., Cheng H., Tewari M. MicroRNA profiling: Approaches and considerations. Nat. Rev. Genet. 2012;13:358–369. doi: 10.1038/nrg3198. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Dellett M., Simpson M.D.A. Considerations for optimization of microRNA PCR assays for molecular diagnosis. Expert Rev. Mol. Diagn. 2016;16:407–414. doi: 10.1586/14737159.2016.1152184. [DOI] [PubMed] [Google Scholar]
  • 41.Mooney C., Raoof R., El-Naggar H., Sanz-Rodriguez A., Jimenez-Mateos E.M., Henshal D.C. High Throughput qPCR Expression Profiling of Circulating MicroRNAs Reveals Minimal Sex- and Sample Timing-Related Variation in Plasma of Healthy Volunteers. PLoS ONE. 2015;10:e0145316. doi: 10.1371/journal.pone.0145316. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Mussbacher M., Krammer T.L., Heber S., Schrottmaier W.C., Zeibig S., Holthoff H.-P., Pereyra D., Starlinger P., Hackl M., Assinger A. Impact of Anticoagulation and Sample Processing on the Quantification of Human Blood-Derived microRNA Signatures. Cells. 2020;9:1915. doi: 10.3390/cells9081915. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Myklebust M.P., Rosenlund B., Gjengstø P., Bercea B.S., Karlsdottir Á., Brydøy M., Dahl O. Quantitative PCR Measurement of miR-371a-3p and miR-372-p is influenced by hemolysis. Front. Genet. 2019;10:463. doi: 10.3389/fgene.2019.00463. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Merkerova M., Belickova M., Bruchova H. Differential expression of microRNAs in hematopoietic cell lineages. Eur. J. Haematol. 2008;81:304–310. doi: 10.1111/j.1600-0609.2008.01111.x. [DOI] [PubMed] [Google Scholar]
  • 45.Mompeón A., Ortega-Paz L., Vidal-Gómez X., Costa T.J., Pérez-Cremades D., Garcia-Blas S., Brugaletta S., Sanchis J., Sabate M., Novella S., et al. Disparate miRNA expression in serum and plasma of patients with acute myocardial infarction: A systematic and paired comparative analysis. Sci. Rep. 2020;10:5373. doi: 10.1038/s41598-020-61507-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Bryzgunova O., Konoshenko M., Zaporozhchenko I., Yakovlev A., Laktionov P. Isolation of Cell-Free miRNA from Biological Fluids: Influencing Factors and Methods. Diagnostics. 2021;11:865. doi: 10.3390/diagnostics11050865. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Farina N.H., Wood M.E., Perrapato S.D., Francklyn C.S., Stein G.S., Stein J.L., Lian J.B. Standardizing analysis of circulating microRNA: Clinical and biological relevance. J. Cell Biochem. 2014;115:805–811. doi: 10.1002/jcb.24745. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Khan J., Lieberman J.A., Lockwood C.M. Variability in, variability out: Best practice recommendations to standardize pre-analytical variables in the detection of circulating and tissue microRNAs. Clin. Chem. Lab. Med. 2017;55:608–621. doi: 10.1515/cclm-2016-0471. [DOI] [PubMed] [Google Scholar]
  • 49.Schrader C., Schielke A., Ellerbroek L., Johne R. PCR inhibitors—Occurrence, properties and removal. J. Appl. Microbiol. 2012;113:1014–1026. doi: 10.1111/j.1365-2672.2012.05384.x. [DOI] [PubMed] [Google Scholar]
  • 50.Unger C., Lokmer N., Lehmann D., Axmann L.M. Detection of phenol contamination in RNA samples and its impact on qRT-PCR results. Anal. Biochem. 2019;571:49–52. doi: 10.1016/j.ab.2019.02.002. [DOI] [PubMed] [Google Scholar]
  • 51.Lee J.T., Cheung K.M., Leung V.Y. Correction for concentration overestimation of nucleic acids with phenol. Anal. Biochem. 2014;465:179–186. doi: 10.1016/j.ab.2014.08.006. [DOI] [PubMed] [Google Scholar]
  • 52.Garcia-Elias A., Alloza L., Puigdecanet E., Nonell L., Tajes M., Curado J., Enjuanes C., Diaz O., Bruguera J., Marti-Almor J., et al. Defining quantification methods and optimizing protocols for microarray hybridization of circulating microRNAs. Sci. Rep. 2017;7:7725. doi: 10.1038/s41598-017-08134-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Wright K., de Silva K., Purdie A.C., Plain K.M. Comparison of methods for miRNA isolation and quantification from ovine plasma. Sci. Rep. 2020;10:825. doi: 10.1038/s41598-020-57659-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.El-Khoury V., Pierson S., Kaoma T., Bernardin F., Berchem G. Assessing cellular and circulating miRNA recovery: The impact of the RNA isolation method and the quantity of input material. Sci. Rep. 2016;6:19529. doi: 10.1038/srep19529. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.Niu Y., Zhang L., Qiu H., Wu Y., Wang Z., Zai Y., Liu L., Qu J., Kang K., Gou D. An improved method for detecting circulating microRNAs with S-Poly(T) Plus real-time PCR. Sci. Rep. 2015;5:15100. doi: 10.1038/srep15100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Ban E., Chae D.K., Yoo Y.S., Song E.J. An improvement of miRNA extraction efficiency in human plasma. Anal. Bioanal. Chem. 2017;409:6397–6404. doi: 10.1007/s00216-017-0580-7. [DOI] [PubMed] [Google Scholar]
  • 57.Duy J., Koehler J.W., Honko A.N., Minogue T.D. Optimized microRNA purification fromTRIzol-treated plasma. BMC Genomics. 2015;16:95. doi: 10.1186/s12864-015-1299-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Mestdagh P., Van Vlierberghe P., De Weer A., Muth D., Westermann F., Speleman F., Vandesompele J. A novel and universal method for microRNA RT-qPCR data normalization. Genome Biol. 2009;10:R64. doi: 10.1186/gb-2009-10-6-r64. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Xiang M., Zeng Y., Yang R., Xu H., Chen Z., Zhong J., Xie H., Xu Y., Zeng X. U6 is not a suitable endogenous control for the quantification of circulating microRNAs. Biochem. Biophys. Res. Commun. 2014;454:210–214. doi: 10.1016/j.bbrc.2014.10.064. [DOI] [PubMed] [Google Scholar]
  • 60.Donati S., Ciuffi S., Brandi M.L. Human Circulating miRNAs Real-time qRT-PCR-based Analysis: An Overview of Endogenous Reference Genes Used for Data Normalization. Int. J. Mol. Sci. 2019;20:4353. doi: 10.3390/ijms20184353. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Madadi S., Schwarzenbach H., Lorenzen J., Soleimani M. MicroRNA expression studies: Challenge of selecting reliable reference controls for data normalization. Cell Mol. Life Sci. 2019;76:3497–3514. doi: 10.1007/s00018-019-03136-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Zhang Y., Tang W., Peng L., Tang J., Yuan Z. Identification and validation of microRNAs as endogenous controls for quantitative polymerase chain reaction in plasma for stable coronary artery disease. Cardiol. J. 2016;6:694–703. doi: 10.5603/CJ.2016.0109. [DOI] [PubMed] [Google Scholar]
  • 63.Wang X., Zhang X., Yuan J., Wu J., Deng X., Peng J., Wang S., Yang C., Ge J., Zou Y. Evaluation of the performance of serum miRNAs as normalizers in microRNA studies focused on cardiovascular disease. J. Thorac. Dis. 2018;10:2599–2607. doi: 10.21037/jtd.2018.04.128. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 64.Schwarzenbach H., da Silva A.M., Calin G., Pantel K. Which is the accurate data normalization strategy for microRNA quantification? Clin. Chem. 2015;61:1333–1342. doi: 10.1373/clinchem.2015.239459. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.Sanders I., Holdenrieder S., Walgenbach-Brünagel G., von Ruecker A., Kristiansen G., Müller S.C., Ellinger J. Evaluation of reference genes for the analysis of serum miRNA in patients with prostate cancer, bladder cancer and renal cell carcinoma. Int. J. Urol. 2012;19:1017–1025. doi: 10.1111/j.1442-2042.2012.03082.x. [DOI] [PubMed] [Google Scholar]
  • 66.Vigneron N., Meryet-Figuière M., Guttin A., Issartel J.P., Lambert B., Briand M., Louis M.H., Vernon M., Lebailly P., Lecluse Y., et al. Towards a new standardized method for circulating miRNAs profiling in clinical studies: Interest of the exogenous normalization to improve miRNA signature accuracy. Mol. Oncol. 2016;10:981–992. doi: 10.1016/j.molonc.2016.03.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67.Ramshani Z., Zhang C., Richards K., Chen L., Xu G., Stiles B.L., Hill R., Senapati S., Go D.B., Chang H.-C. Extracellular vesicle microRNA quantification from plasma using an integrated microfluidic device. Commun. Biol. 2019;2:189. doi: 10.1038/s42003-019-0435-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 68.Butz H., Patócs A. In: Circulating microRNAs in Disease Diagnostics and Their Potential Biological Relevance. Igaz P., editor. Springer; Basel, Switzerland: 2015. pp. 55–71. [Google Scholar]
  • 69.Zununi Vahed S., Barzegari A., Rahbar Saadat Y., Mohammadi S., Samadi N. A microRNA isolation method from clinical samples. BioImpacts. 2016;6:25–31. doi: 10.15171/bi.2016.04. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Ban E., Kwon H., Seo H.S., Yoo Y.S., Song E.J. Screening of miRNAs in plasma as a diagnostic biomarker for cardiac disease based on optimization of extraction and qRT-PCR condition assay through amplification efficiency. BMC Biotechnol. 2021;21:50. doi: 10.1186/s12896-021-00710-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 71.Svec D., Tichopad A., Novosadova V., Pfaffl M.W., Kubista M. How good is a PCR efficiency estimate: Recommendations for precise and robust qPCR efficiency assessments. Biomol. Detect. Quantif. 2015;3:9–16. doi: 10.1016/j.bdq.2015.01.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 72.Balcells I., Citrera S., Busk P.K. Specific and sensitive quantificative RT-PCR of miRNAs with DNA primers. BMC Biotechnol. 2011;11:70. doi: 10.1186/1472-6750-11-70. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 73.Sreedharan S.P., Kumar A., Giridhar P. Primer design and amplification efficiencies are crucial for reliability of quantitative PCR studies of caffeine biosynthetic N-methyltransferases in coffee. 3 Biotech. 2018;8:467. doi: 10.1007/s13205-018-1487-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 74.Cirera S., Andersen-Ranberg E.U., Langkilde S., Aaquist M., Greda H. Challenges and standardization of microRNA profling in serum and cerebrospinal fluid in dogs suffering from non-infectious infammatory CNS disease. Acta Vet. Scand. 2019;61:57. doi: 10.1186/s13028-019-0492-y. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from Genes are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES