The Serological Sciences Network (SeroNet) for COVID-19: Depth and Breadth of Serology Assays and Plans for Assay Harmonization

Amy B Karger 1,*, James D Brien 2, Jayne M Christen 3, Santosh Dhakal 4, Troy J Kemp 3, Sabra L Klein 4, Ligia A Pinto 3, Lakshmanane Premkumar 5, John D Roback 6, Raquel A Binder 7, Karl W Boehme 8, Suresh Boppana 9,10, Carlos Cordon-Cardo 11, James M Crawford 12, John L Daiss 13, Alan P Dupuis II 14, Ana M Espino 15, Adolfo Firpo-Betancourt 11, Catherine Forconi 7, J Craig Forrest 8, Roxie C Girardin 14, Douglas A Granger 16, Steve W Granger 16, Natalie S Haddad 17, Christopher D Heaney 18, Danielle T Hunt 14, Joshua L Kennedy 19,20, Christopher L King 21, Florian Krammer 22, Kate Kruczynski 18, Joshua LaBaer 23, F Eun-Hyung Lee 17, William T Lee 14,24, Shan-Lu Liu 25, Gerard Lozanski 26, Todd Lucas 27, Damodara Rao Mendu 11, Ann M Moormann 7, Vel Murugan 23, Nkemakonam C Okoye 12, Petraleigh Pantoja 28,#a, Anne F Payne 14, Jin Park 23, Swetha Pinninti 9, Amelia K Pinto 2, Nora Pisanic 18, Ji Qiu 23, Carlos A Sariol 28,29, Viviana Simon 22, Lusheng Song 23, Tara L Steffen 2, E Taylor Stone 2, Linda M Styer 14,24, Mehul S Suthar 30, Stefani N Thomas 1, Bharat Thyagarajan 1, Ania Wajnberg 31, Jennifer L Yates 14,24, Kimia Sobhani 32
PMCID: PMC8902887  PMID: 35262095

Abstract

Background:

In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and “to develop, validate, improve, and implement serological testing and associated technologies.” SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization.

Methods:

To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data.

Results:

SeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards.

Conclusions:

SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.

Introduction

The National Cancer Institute (NCI) Serological Sciences Network for COVID-19, or SeroNet, was launched on October 8, 2020, as a collaborative initiative to expand research on immune responses to SARS-CoV-2. SeroNet is comprised of investigators from 25 US biomedical research institutions, working in partnership with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center, which is managed by the FNLCR.1 Of the 25 participating research institutions, 8 are designated as Serological Sciences Centers of Excellence (funded by U54 grants), 13 are funded with U01 grants to carry out specific research projects related to COVID-19 immunity, and 4 institutions are funded by subcontracts and are designated as Serological Sciences Network Capacity Building Centers.1

One of the primary goals of this partnership is “to develop, validate, improve, and implement serological testing and associated technologies.”1 To this end, SeroNet formed a working group, the Serology Assays, Samples, and Materials Operations Group (abbreviated as “Serology Assay Ops”), in December 2020 to allow for coordinated development and collaborative sharing of serology assay procedures, and to establish processes for harmonizing and standardizing methodologies using reference materials across institutions. Establishing harmonized and standardized SARS-CoV-2 serological assays can allow cross-comparison and pooling of research study results and facilitate clinical interpretation of results for patient care.

While there are 85 serological assays approved by the FDA for emergency use,2 the quick development of assays has led to the lack of harmonized cut-offs and reporting units. Furthermore, there are no consensus guidelines on reporting standards or clarity on the clinical interpretation and relevance of results. This has created a complex landscape for interpreting both research and clinical serological assay results. For example, several studies have reported on heterogeneity in serological assay performance that would have a significant impact on research study conclusions and clinical interpretations related to longitudinal serosurveillance.36 Specifically, certain assays demonstrate reduced sensitivity over time after an initial SARS-CoV-2 infection diagnosis. Muecksch et al. reported that the Abbott SARS-CoV-2 anti-Nucleocapsid IgG assay dropped from a peak sensitivity of 98% at 21 – 40 days post-PCR diagnosis, to around 70% when patients were tested ≥ 81 days post-diagnosis, whereas the Roche Elecsys SARS-CoV-2 anti-Nucleocapsid total antibody assay and Siemens SARS-CoV-2 anti-receptor-binding domain (RBD) total antibody assay both maintained high sensitivity (95 – 100%) on the same set of serial samples. Narowski et al. also found a significant decline in the longitudinal sensitivity of their lab-developed nucleocapsid assay in a study of healthcare workers.6 Perez-Saez et al. similarly demonstrated that the rates of sero-reversion at least 8 months after the initial infection differed greatly depending on the serological assay used.4 While the sero-reversion rate of the EuroImmun semiquantitative anti-S1 IgG ELISA was 26%, the rate was significantly lower for the Roche anti-Nucleocapsid total antibody assay (1.2%) and the Roche semiquantitative anti-RBD total antibody assay (0%).4 Additionally, numerous studies rely on neutralization assays as gold standard methods for determining the functional relevance of ligand-binding methods, but comparison studies have demonstrated variability in results for live-virus neutralization, pseudovirus neutralization, and surrogate neutralization assays (e.g., ACE2 inhibition assays),79 raising the importance of assay harmonization and standardization across laborartories.

Therefore, SeroNet aims to address these knowledge gaps in SARS-CoV-2 serological assay research by establishing collaborative initiatives to characterize, compare, and harmonize SARS-CoV-2 serological assays. This manuscript describes the depth and breadth of serological assays developed and implemented within the SeroNet consortium, and outlines a proposed process to establish assay traceability to the U.S. SARS-CoV-2 serology standard reference material and to the WHO International Standard (WHO IS 20/136) for these diverse assays, with the ultimate goal of establishing harmonized reporting standards. This will facilitate cross-comparison of results and provide clarity for their clinical interpretation, including in response to circulating SARS-CoV-2 variants.

Methods

Compilation of data on SeroNet serological assays

SeroNet institutions were queried by email between January and July 2021 and asked to complete a comprehensive serological assay survey to describe serological assays developed or implemented at their institution. The survey requested information on assay and sample type(s), instrument platform and reagents, data output, antibody isotype(s) detected, targeted antigens and virus strain(s), assay performance, cut-offs, use of standards and quality controls, method comparison studies, regulatory status, current use/applications for assays, and publications using each assay.

Protocol for establishing traceability of serology assays to the U.S. SARS-CoV-2 serology standard and First WHO International Standard for anti-SARS-CoV-2 immunoglobulin

FNLCR developed a recommended protocol for SeroNet institutions to establish serology assay traceability to the U.S. SARS-CoV-2 Serology Standard. In short, for enzyme-linked immunosorbent assay platforms (ELISA), the U.S. SARS-CoV-2 standard is measured on the same 96-well plate as the daily assay standard, run as serial dilutions in triplicate and quadruplicate respectively (Figure 1). Standard curves are constructed for both the U.S. SARS-CoV-2 Serology standard and daily assay standard. A test of parallelism and linearity between the two dose-response curves is then performed to ensure that immunoaffinity differences or matrix effects do not prevent accurate calibration with the U.S. SARS-CoV-2 Serology Standard. Units based on the U.S. SARS-CoV-2 serology standard can then be assigned to the assay daily standard, to harmonize assays and units for results reporting. For non-plate-based assay platforms, similar dilution-based standard curves are constructed.

Figure 1:

Figure 1:

Example plate map for assay calibration set-up

Numbers indicate suggested serial dilutions. Serial dilutions of primary and secondary calibrators (reference materials) are plated in triplicate, and the daily internal assay standard is plated in quadruplicate.

C_STD: Daily internal assay standard

STD-C1, C2, and C3: Primary calibrator (primary reference material or standard)

STD-T1, T2, and T3: Secondary calibrator (secondary reference material or standard)

NEG: Negative control sample

PC1: Positive control sample 1

PC2: Positive control sample 2

Traceability of the FNLCR standard to the First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136) was established, to allow SeroNet assays to convert U.S. Serology Standard units to WHO IS units. The WHO IS 20/136 is a freeze-dried equivalent of 0.25 mL of pooled plasma from 11 individuals with a history of SARS-CoV-2 infection. Once reconstituted the WHO standard has an arbitrary unitage of 1000 binding antibody units (BAU)/mL. Eight serial dilutions of the U.S. SARS-CoV-2 serology standard and WHO IS 20/136 were run in triplicate. Parallel line analysis, which included tests for parallelism and linearity, was utilized to assign WHO IS 20/136 standard units to the U.S. SARS-CoV-2 serology standard; this will allow SeroNet institutions to convert U.S. SARS-CoV-2 serology standard units to WHO standard units for serological methods.

Results

SeroNet Serology Assay data

Of the 25 institutions involved with SeroNet, 23 institutions reported performing between one to seven serology assays, and provided descriptive and performance data. Serology assay data were also obtained from the Frederick National Laboratory for Cancer Research (FNLCR) and National Institute of Standards and Technology (NIST), both of which collaborate with SeroNet. Collectively, Seronet institutions reported development of 27 in-house ELISA methods (Table 1).6,1026 The majority of ELISA methods were developed for testing of serum and/or plasma, with additional methods available for testing dried blood spots (DBS), saliva/oral fluid, and breast milk. Two methods have been granted FDA EUA approval, 3 methods are pending FDA EUA, 4 methods are validated for high-complexity testing in a CLIA-certified laboratory, and 18 methods are for research-use only (RUO). Diagnostic sensitivity and specificity for in-house ELISA methods ranged from 67.4 – 100 % and 90 – 100%, respectively.

Table 1:

Laboratory-developed singleplex ELISA assays

Sample Type Antigen Isotype Assay Sensitivity & Specificity Center/Institution References Regulatory Status
Serum, Plasma, Dried Plasma samples RBD IgG (IgA/IgM being eval) Day 0–7 after infection: Sensitivity 73.01%; Day 8–14 after infection: Sensitivity 100%; Day ≥ 15 after infection: Sensitivity 100%; Specificity (n=388 samples collected prior to COVID-19 pandemic): 97.68% Emory University PMID: 32835303 FDA EUA granted
Serum, Plasma RBD and Spike IgG, IgM, IgA Sensitivity 95%, Specificity 100% (n=38 positive, n=74 negative sera tested) Mount Sinai PMID: 32302069, PMID: 32511441, PMID: 33142304 FDA EUA granted
Serum, Plasma, Saliva RBD Total Ig, with IgG, IgM, IgA titers Overall sensitivity 82.5%, overall specificity 100% (n=300); At > 14 days from symptom onset, sensitivity 100%, specificity 100% (n=261); University of Minnesota PMID: 32791053, PMID: 33539808 Assays validated in a high-complexity testing CLIA laboratory
Serum, Plasma RBD IgG, IgM Sensitivity: 91% for RBD IgG 15–21 days post onset of symptoms, 100% >21 days post-onset of symptoms; 90% for RBD IgM 15–21 days post onset of symptoms, 100% >21 days post-onset of symptoms. Specificity: 99.75% for RBD IgG, 100% for RBD IgM Stanford University PMID: 33288645 Assays validated in a high-complexity testing CLIA laboratory
Serum, Plasma RBD-ACE2 Total IgG that blocks RBD-ACE2 binding N/A, used as a follow-up assay in seropositive specimens Stanford University PMID: 33288645 Assay validated in a high-complexity testing CLIA laboratory
Serum, Plasma RBD IgG, IgM + IgG Sensitivity 98% (n=181), Specificity 98.9% (n=181). University of Puerto Rico PMID: 34696403,
https://www.biorxiv.org/content/10.1101/2020.06.11.146332v2
Assay validated in a high-complexity testing CLIA laboratory
Serum, Plasma Spike IgG Sensitivity 98.3% (n=60), Specificity 99.3% (n=150) Frederick National Laboratory NR RUO
Serum, Plasma Spike IgM Sensitivity 93.8% (n=30), Specificity 97.6% (n=80) Frederick National Laboratory NR RUO
Serum, Plasma Nucleocapsid IgG Sensitivity 97% (n=34), Specificity 100% (n=99) Frederick National Laboratory NR RUO
Serum, Plasma Nucleocapsid IgM NR Frederick National Laboratory NR RUO
Serum, Plasma, Saliva RBD Total Ig Sensitivity 95% (n=259; 9 or more days after symptom onset), Specificity 96% (n=535) University of North Carolina PMID: 32527802, 35090596 FDA EUA pending
Serum, Plasma, Saliva Spike NTD Total Ig Sensitivity = 92% (n=259; 9 or more days after symptom onset), Specificity = 94% (n=535) University of North Carolina PMID: 35090596 FDA EUA pending
Serum Spike, RBD IgG NR CVVR/BIDMC/Harvard PMID: 34107529 RUO
Serum, Plasma, Breast milk RBD IgG, IgA, IgM NR CVVR/BIDMC/Harvard PMID: 33983379, PMID: 33893169 RUO
Serum, Plasma Spike IgG Sensitivity 100%, Specificity 98.8% Tulane University NR RUO
Serum, Plasma RBD IgG NR Tulane University NR RUO
Serum, Plasma Nucleocapsid IgG NR Tulane University NR RUO
Plasma, Serum Spike, RBD IgM, IgG, IgA Spike: IgG (Sensitivity 96.6%, Specificity 96.7%); IgA (Sensitivity 99.3%, Specificity 90%); IgM (Sensitivity 97.9%, Specificity 100%). RBD: IgG (Sensitivity 97.3%, Specificity 100%); IgA (Sensitivity 99.3%, Specificity 96.7%); IgM (Sensitivity 97.9%, Specificity 96.7%). IgG data based on n=126 convalescent plasma donors, n=30 pre-pandemic samples; IgM/IgA data based on n=20 hospitalized, n=30 pre-pandemic samples. Johns Hopkins University PMID: 32764200 RUO
Serum, Plasma Spike (ECD), RBD IgG NR University of Texas-Austin PMID: 32910806 RUO
Serum, Plasma RBD IgG Sensitivity 100% (n=155), Specificity 96.5% (n=133) Arizona State University NR RUO
Serum, DBS RBD IgG, IgM Sensitivity 97% (n=39), Specificity 100% (n=37) University of Arkansas for Medical Sciences PMID: 34478478,
https://www.medrxiv.org/content/10.1101/2021.08.04.21261592v3
RUO
Serum, DBS RBD, Spike, Nucleocapsid IgG, IgM Sensitivity 97% (n=39), Specificity 100% (n=37) University of Arkansas for Medical Sciences PMID: 34478478,
https://www.medrxiv.org/content/10.1101/2021.08.04.21261592v3
RUO
Serum, Plasma, Breast milk RBD, Spike, Nucleocapsid IgG, IgM, IgA 97% Sensitivity (n=114), Specificity 99% University of Alabama-Birmingham NR RUO
Serum, Plasma RBD, Nucleocapsid, Spike Trimer IgG, IgA RBD: Sensitivity (70.9% for IgG, 74.4% for IgA) and Specificity (100% for both IgG and IgA); Nucleocapsid: Sensitivity (81.4% for IgG, 77.9% for IgA) and Specificity (98.5% for IgG, 100% for IgA); Spike Trimer: Sensitivity (67.4% for both IgG and IgA) and Specificity (98.5% for IgG, 100% for IgA). Data based on PCR confirmed COVID-19 hospitalized patients (n=86) and negative pre-pandemic samples (n=65). University of Massachusetts Chan Medical School PMID: 32780998 RUO
Serum, Plasma Nucleocapsid IgG Sensitivity 100% (n=44), Specificity 99.5% (n=202) The Ohio State University PMID: 33035201 FDA EUA pending
Serum Nucleocapsid IgG NR The Ohio State University NR RUO
Oral fluid Nucleocapsid IgG Sensitivity 92% (n=24), Specificity 98% (n=85) Salimetrics NR RUO

ACE2: Angiotensin converting enzyme-2; BIDMC: Beth Israel Deaconess Medical Center; CLIA: Clinical Laboratory Improvement Amendments; CVVR: Center for Virology and Vaccine Research; DBS: Dried blood spots; ECD: Extracellular domain; EUA: Emergency Use Authorization; FDA: Food and Drug Administration; NR: Not reported; NTD: N-terminal domain; PMID: PubMed Identifier; RBD: receptor binding domain; RUO: research use only

Eight institutions reported development or use of multiplex or protein arrays for antibody detection (Table 2).2737 Sample types include serum, plasma, DBS, saliva, and bronchoalveolar lavage (BAL) fluid. Diagnostic sensitivity and specificity for multiplex and protein array methods range from 85 – 98.8 % and 95.2 – 100 %, respectively. Neutralization assays were developed by 9 institutions, with sample types including serum, plasma, BAL fluid, nasal wash, DBS, and breast milk (Table 3).15,24,29,3850 Assays fall into three mechanistic categories – competitive binding assays, pseudotyped neutralization assays, and live virus neutralization assays. The competitive binding assay measures the ability of antibodies to block interactions between the SARS-CoV-2 receptor binding domain and human ACE2 receptor. Virus pseudotype neutralization assays, mainly HIV- and VSV-based, use full length spike incorporated in the viral particle to measure the capability of neutralizing antibodies to block viral entry into the target cells. SARS-CoV-2 live virus plaque or focus reduction neutralization assays measure the ability of neutralizing antibodies to block the spreading infection of authentic SARS-COV-2 in cell culture. Diagnostic sensitivity and specificity for neutralization methods developed within SeroNet range from 93 – 100 % and 97 – 100 %, respectively. Lastly, 9 institutions report use of 12 commercial serology methods (Table 4). Commercial methods detect IgG, IgM, and/or total Ig to spike, RBD, and/or nucleocapsid antigens in serum or plasma. Of the commercial methods in use, 10 are FDA EUA approved, 1 is pending FDA EUA, and 1 is RUO.

Table 2:

Laboratory-developed multiplex assays

Sample Type Antigen Isotype Assay Sensitivity & Specificity Center/Institution References Regulatory Status
DBS, Serum Spike S1, Nucleocapsid IgG Sensitivity: DBS 94% for symptomatic (n=774 samples collected >20 days after PCR+ result) 85% for asymptomatic (n=115 samples collected >20 days after PCR+ result), Specificity: DBS 99% (n=730), Serum 99% (n=701) Wadsworth PMID: 32648546
PMID: 34319133
NYS CLEP-approved
Serum, Plasma, DBS Spike, Nucleocapsid, RBD Total Ig Sensitivity >97%, Specificity 99% Wadsworth PMID: 33104179 FDA EUA granted; NYS CLEP-approved
Serum, Plasma, DBS Spike, Nucleocapsid, RBD IgG, IgM, IgA Sensitivity >97%, Specificity 99% Wadsworth PMID: 34151306 NYS CLEP-approved; FDA EUA pending
Oral fluid, Serum, Plasma Spike, RBD, Nucleocapsid IgG, IgM, IgA Oral fluid IgG assay sensitivity 98.8% ≥ 15 days post symptom onset (n=81), specificity 100% (n=127) Johns Hopkins University, Supporting Michigan State University PMID: 33067270,
34695724
Oral fluid assays validated in a high-complexity testing CLIA laboratory; Serum/plasma RUO
Serum, Plasma, BAL, DBS Spike, RBD (different variants), Nucleocapsid IgG Sensitivity >97% sensitivity (n=89), Specificity 99% (n=260) Case Western Reserve University PMID: 33993265 RUO
Serum, Plasma, Saliva, BAL Spike, RBD, Nucleocapsid IgA Sensitivity >98%, Specificity 99% Case Western Reserve University PMID: 33993265 RUO
Serum, Plasma Spike IgG Sensitivity ≥ 93%, Specificity 100% NIST PMID: 33800363 RUO
Serum, Plasma RBD IgG Sensitivity ≥ 93%, Specificity 100% NIST PMID: 33800363 RUO
Serum, Plasma RBD, Nucleocapsid IgG Nucleocapsid Sensitivity 90.3% (n=155) and Specificity 98.0% (n=133); RBD Sensitivity 90.1% (n=155) and Specificity 97.0% (n=133) Arizona State University NR FDA EUA pending
Serum Spike, Nucleocapsid, RBD IgG, IgM, IgA NR Yale PMID: 33171100 RUO
Serum Alpha, Beta, Gamma, and Delta variants (Spike, RBD) IgG, IgM, IgA NR Yale PMID: 31229590 RUO
Saliva Spike, Nucleocapsid, RBD IgG Sensitivity: Nucleocapsid 97.7%, RBD 92.9%, Spike 98.8%; Specificity: Nucleocapsid 95.2%, RBD 96.4%, Spike 97.6%. (Combined Nucleocapsid & Spike sensitivity 96.5%, specificity 98.8%) Salimetrics NR RUO
Serum, Plasma Spike S1, S1-RBD, Nucleocapsid, S1-NTD IgG, IgA, IgM (combined) IgG, IgA, IgM (individual) Sensitivity: combined antigens and isotypes 99%; S1-RBD combined isotypes 99%, S1-RBD IgG 99%; Specificity: combined antigens and isotypes 99%, S1-RBD combined isotypes 99%, S1-RBD IgG 99%. During the acute phase, Sensitivity 92%, Specificity 99%. Emory/MicroB-plex PMID: 34001652 RUO

BAL: Bronchoalveolar lavage; CLIA: Clinical Laboratory Improvement Amendments; DBS: Dried blood spots; EUA: Emergency use authorization; FDA: Food and Drug Administration; NIST: National Institute of Standards and Technology; NR: Not reported; NYS CLEP: New York State Clinical Laboratory Evaluation Program; PCR: Polymerase chain reaction; PMID: PubMed Identifier; RBD: Receptor binding domain; RUO: Research use only

Table 3:

Neutralization assays

Sample Type Antibody Neutralization Assay Type Assay Sensitivity & Specificity Center/Institution References Regulatory Status
Serum, Plasma, BAL HIV Lentiviral Vector Sensitivity 100%, Specificity 100%, using SeroNet FNLCR blinded reference panel set (n=110) The Ohio State University PMID: 33035201 RUO
Serum, Plasma Live Virus Neutralization Assay (microneutralization) NR Mount Sinai PMID: 32585083
PMID: 33115920
RUO
Serum, Plasma, BAL Live Virus Neutralization Assay (FRNT) Sensitivity 93%, Specificity 100% Saint Louis University PMID: 34100029
PMID: 33326500
RUO
Serum, Plasma, BAL Live Virus Neutralization Assay (FRNT/FRNT-mNG/PRNT) NR Emory PMID: 33215858. RUO
Serum, Plasma, DBS Live Virus Neutralization Assay (PRNT) PRNT50: Sensitivity 100%, Specificity 97%; PRNT90: Sensitivity 97%, Specificity 100% Wadsworth PMID: 33104179
PMID: 33417696
NYS CLEP-approved (serum and plasma)
Serum, plasma, breast milk VSV Pseudotype Particle based assay NR University of Alabama Birmingham NR RUO
Serum, Plasma, Nasal Washes TCID50 Neutralization Assay NR Johns Hopkins University PMID: 34253053
PMID: 33571169
PMID: 33571162
PMID: 33427749
PMID: 33139419
PMID: 32764200
RUO
Serum, Plasma ACE2 Competitive Binding Assay Sensitivity 93.8% Specificity 99.4% University of Puerto Rico PMID: 34100029 RUO
Serum, plasma Lentiviral based pseudovirus assay for Wuhan D614G, Brazil, South Africa, and Delta variants. Assay performed in CHO/ACE2 cells. Sensitivity 100%, Specificity 100% Tulane PMID: 33306985 RUO

ACE2: Angiotensin converting enzyme-2; BAL: Bronchoalveolar lavage; CHO: Chinese hamster ovary; DBS: Dried blood spots; EUA: Emergency use authorization; FDA: Food and Drug Administration; FNLCR: Frederick National Laboratory for Cancer Research; FRNT: Focus reduction neutralization test; HIV: Human immunodeficiency virus; mNG: mNeonGreen; NR: Not reported; NYS CLEP: New York State Clinical Laboratory Evaluation Program; PMID: PubMed Identifier; PRNT: Plaque reduction neutralization test; RUO: Research use only; TCID: Tissue culture infectious dose; VSV: Vesicular stomatitis virus

Table 4:

Commercial assays

Instrument/Assay Antigen Isotype Center/Institution Regulatory Status
Abbott Alinity Spike IgM Mount Sinai FDA EUA granted
Abbott Architect Spike, Nucleocapsid IgG Cedars-Sinai* FDA EUA granted
Beckman Coulter Access Spike IgG Arizona State University FDA EUA granted
Beckman Coulter Access Spike IgM Arizona State University FDA EUA granted
DiaSorin Liaison Spike IgG Feinstein/Northwell, Kaiser, The Ohio State University FDA EUA granted
DiaSorin Liaison Spike IgM Feinstein/Northwell FDA EUA granted
Kantaro SeroKlir Spike, RBD IgG Mount Sinai FDA EUA granted
Kantaro Quantitative SARS-CoV-2 Spike, RBD IgG Mount Sinai FDA EUA pending
Meso Scale Discovery Spike, Nucleocapsid IgG, IgM University of Alabama - Birmingham, CVVR/BIDMC/Harvard, Johns Hopkins University, Stanford RUO
Roche Elecsys Anti-SARS-CoV-2 Nucleocapsid Total Ig University of Minnesota, Feinstein/Northwell FDA EUA granted
Roche Elecsys Anti-SARS-CoV-2 S RBD Total Ig University of Minnesota, Feinstein/Northwell FDA EUA granted
Siemens Atellica Spike Total Ig Kaiser, The Ohio State University FDA EUA granted
*

Samples sent to Abbott Diagnostics for testing

BIDMC: Beth Israel Deaconess Medical Center; CVVR: Center for Virology and Vaccine Research; EUA: Emergency use authorization; FDA: Food and Drug Administration; RBD: Receptor binding domain; RUO: Research use only

Establishment of SeroNet assay traceability to the U.S. SARS-CoV- 2 Serology Standard and First WHO International Standard for anti-SARS-CoV-2 Immunoglobulin

Units for the U.S. SARS-CoV-2 Serology standard were initially established by FNLCR based on measurements performed by eight laboratories (Table 5). Subsequently, FNLCR further established traceability of the U.S. SARS-CoV-2 Serology standard to the WHO IS 20/136 by using four FNLCR ligand binding serology assays, with assessment of neutralization tested at NIAID’s Integrated Research Facility (IRF) (Table 5). The U.S. SARS-CoV-2 serology standard was made available to the public in December 2020. Thus far, there have been 124 requests for U.S. SARS-CoV-2 standard material, and 19 requests for the reference panel samples.

Table 5:

Units assigned to the U.S. SARS-CoV-2 Serology Standard

Units assigned by FNLCR WHO-calibrated units
Functional activity Spike & Nucleocapsid IgM Spike & Nucleocapsid IgG Functional activity Spike IgG Nucleocapsid IgG Spike IgM Nucleocapsid IgM
200 NU/mL 100 BAU/mL 1200 BAU/mL 815 IU/mL 764 BAU/mL 681 BAU/mL 246 BAU/mL 1037 BAU/mL

FNLCR: Frederick National Laboratory for Cancer Research; WHO: World Health Organization; NU/mL: Neutralizing Units per milliliter; BAU/mL: Binding Assay Units per milliliter; IU/mL: International units per milliliter

Discussion

SeroNet has collectively established a diverse array of methodologies for measurement of SARS-CoV-2 antibodies in a variety of biological fluids. Methods include laboratory-developed ELISAs, multiplex assays, and neutralization assays, most used for research-only purposes, as well as commercial assays available for patient care or research studies. Assays have been developed to test unique sample types, including DBS, saliva/oral fluid, breast milk, nasal washes, and bronchoalveolar lavage fluid. Binding assays identify IgM, IgG, IgA, and/or total antibodies to nucleocapsid, spike, RBD and/or N-terminal domain (NTD) antigens, and neutralization assays rely on three methods to quantify antibodies with functional neutralizing activity. This diversity of assay methods allows for robust investigation of multiple aspects of the serological response to SARS-CoV-2 infection and vaccination, and for cross-comparison of assay performance across platforms and institutions within SeroNet.

With the rapid development of numerous methods for serological assessment, as exemplified by the depth and breadth of assays within SeroNet, it is critical to establish assay harmonization and standardized reporting units to facilitate cross-comparison of results across studies, as well as for streamlined meta-analyses. To this end, FNLCR has provided the U.S. SARS-CoV-2 serology standard reference material, which has traceability to the First WHO International Standard for anti-SARS-CoV-2 Immunoglobulin, to SeroNet sites performing serological assays, to allow establishment of standardized reporting of results in binding antibody units (BAU) per mL traceable to the WHO standard. These efforts may more rapidly facilitate the establishment of a universal cut-off as a correlate of protection, which will be critical to broaden the clinical utility of serological testing for patient care, will allow vaccine trials to transition to an immunogenicity endpoint rather than morbidity or mortality endpoints (immuno-bridging), and will guide decisions regarding optimal scheduling of future vaccine doses to optimize protective efficacy for the general immunocompetent population and susceptible immunocompromised sub-populations.

In summary, SeroNet is well-positioned to rapidly and collaboratively advance our understanding of the immune response to both SARS-CoV-2 infection and vaccination, with ongoing evaluation of serological responses to SARS-CoV-2 variants of concern. The collective effort of institutions involved with SeroNet, to both establish diverse and complementary serological assays, and establish traceability of these diverse assays to the WHO standard, will allow for comprehensive investigation of immune responses and facilitate pooled analyses within the SeroNet consortium. This will enable achievement of the ultimate goal – establishment of a universal correlate of protection cut-off, which will provide a foundation for broader clinical use of serologic testing, as a guide for future decisions on scheduling of COVID-19 vaccine boosters, as well as for general assessment of COVID-19 vaccine immune responses against vaccine viruses and newly evolving variants of concern.

Acknowledgments

Funding sources.

Funded by NCI Contract No. 75N91019D00024, Task Order No. 75N91021F00001, award numbers 21X089 (J.L., V.M., J.P., J.Q., L.S.), 21X090 (J.M.C., N.C.O.), 21X091 (A.B.K., S.N.T., B.T.), and 21X092 (C.C-C., A.F-B., F.K., D.R.M., V.S., A.W.); and NCI Grants U54CA260591 (K.S.), U01CA260469 (T.L., D.A.G., S.W.G., C.D.H., K.K., N.P.), U54CA260543 (L.P.), U54CA260582 (S-L.L., G.L.), U54CA260492 (S.L.K., S.D.), U54CA260563 (F.E-H.L., M.S.S., N.S.H., J.L.D., J.D.R.), U01CA260541 (J.D.B., A.K.P., T.L.S., E.T.S., C.A.S., P.P., A.M.E.), U01CA260526 (K.W.B., J.C.F., J.L.K.), U01CA261276 (R.A.B., C.F., A.M.M.), U01CA260539 (C.L.K.), U01CA260508 (L.M.S., A.P.D., R.C.G., D.T.H., W.T.L., J.L.Y., A.F.P.), U01CA260462 (S.B., S.P.).

Potential conflicts of interest.

A.B.K. is a consultant for Roche Diagnostics and has received research support from Siemens Healthcare Diagnostics and Kyowa Kirin Pharmaceutical Development. J.D.B., A.K.P., E.T.S., and T.L.S. have received research support from Altimmune. J.D.R. and M.S.S. are co-inventors on a patent filed by Emory University covering the serology assay described in this manuscript. M.S.S. serves on the advisory board for Moderna and Ocugen. F.E.L. is the founder of MicroB-plex, Inc. J.L.D. is the CSO of MicroB-plex, Inc. N.S.H. has been a senior scientist at MicroB-plex, Inc. F.E.L. has research grants from the Gates Foundation and Genentech, is on the SAB of Be Biopharma, Inc., and received royalties from BLI, Inc., as an inventor for the plasma cell survival media. S.B. has research support from Merck and Pfizer, and is a member of the CMV Vaccine Advisory Committees of Merck and Moderna. S.P. has research support from Moderna. D.A.G. is the Chief Scientific and Strategy Advisor of Salimetrics, LLC. S.W.G. is the Chief Scientific Officer of Salimetrics, LLC. Mount Sinai has licensed serological assays to commercial entities and has filed for patent protection for serological assays. The Icahn School of Medicine at Mount Sinai has filed patent applications relating to the COVID-19 serological assay (“Serology Assay”) and NDV-based SARS-CoV-2 vaccines which list F.K. (“Serology Assay”, vaccines), V.S. (“Serology Assay”), A.F-B. (“Serology Assay”), D.R.M. (“Serology Assay”), and C.C-C. (“Serology Assay”) as co-inventors. The foundational “Serology Assay” intellectual property (IP) was licensed by the Icahn School of Medicine at Mount Sinai to commercial entities including Kantaro Biosciences, a company in which Mount Sinai has a financial interest. All remaining authors report no relevant conflicts of interest.

References

  • 1.NCI Serological Sciences Network for COVID-19 (SeroNet). Accessed December 2, 2021. https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serologicalsciences-network
  • 2.In Vitro Diagnostics EUAs - Serology and Other Adaptive Immune Response Tests for SARS-CoV-2. Food and Drug Administration (FDA). Accessed December 2, 2021. https://www.fda.gov/medicaldevices/coronavirus-disease-2019-covid-19-emergency-use-authorizations-medical-devices/in-vitrodiagnostics-euas-serology-and-other-adaptive-immune-response-tests-sars-cov-2
  • 3.Muecksch F, Wise H, Batchelor B, et al. Longitudinal Serological Analysis and Neutralizing Antibody Levels in Coronavirus Disease 2019 Convalescent Patients. J Infect Dis. 02 13 2021;223(3):389–398. doi: 10.1093/infdis/jiaa659 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Perez-Saez J, Zaballa ME, Yerly S, et al. Persistence of anti-SARS-CoV-2 antibodies: immunoassay heterogeneity and implications for serosurveillance. Clin Microbiol Infect. Nov 2021;27(11):1695.e7–1695.e12. doi: 10.1016/j.cmi.2021.06.040 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Muecksch F, Wise H, Templeton K, et al. Longitudinal variation in SARS-CoV-2 antibody levels and emergence of viral variants: implications for the ability of serological assays to predict immunity. medRxiv. Jul 07 2021;doi: 10.1101/2021.07.02.21259939 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Narowski TM, Raphel K, Adams LE, et al. SARS-CoV-2 mRNA vaccine induces robust specific and cross-reactive IgG and unequal neutralizing antibodies in naive and previously infected people. Cell Rep. Jan 20 2022:110336. doi: 10.1016/j.celrep.2022.110336 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Sholukh AM, Fiore-Gartland A, Ford ES, et al. Evaluation of Cell-Based and Surrogate SARS-CoV-2 Neutralization Assays. J Clin Microbiol. 09 20 2021;59(10):e0052721. doi: 10.1128/JCM.00527-21 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.von Rhein C, Scholz T, Henss L, et al. Comparison of potency assays to assess SARS-CoV-2 neutralizing antibody capacity in COVID-19 convalescent plasma. J Virol Methods. 02 2021;288:114031. doi: 10.1016/j.jviromet.2020.114031 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Olbrich L, Castelletti N, Schälte Y, et al. Head-to-head evaluation of seven different seroassays including direct viral neutralisation in a representative cohort for SARS-CoV-2. J Gen Virol. 10 2021;102(10)doi: 10.1099/jgv.0.001653 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Röltgen K, Powell AE, Wirz OF, et al. Defining the features and duration of antibody responses to SARS-CoV-2 infection associated with disease severity and outcome. Sci Immunol. 12 07 2020;5(54)doi: 10.1126/sciimmunol.abe0240 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Alter G, Yu J, Liu J, et al. Immunogenicity of Ad26.COV2.S vaccine against SARS-CoV-2 variants in humans. Nature. 08 2021;596(7871):268–272. doi: 10.1038/s41586-021-03681-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Amanat F, Stadlbauer D, Strohmeier S, et al. A serological assay to detect SARS-CoV-2 seroconversion in humans. medRxiv. Apr 16 2020;doi: 10.1101/2020.03.17.20037713 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Arthur JM, Forrest JC, Boehme KW, et al. Development of ACE2 autoantibodies after SARS-CoV-2 infection. PLoS One. 2021;16(9):e0257016. doi: 10.1371/journal.pone.0257016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Collier AY, McMahan K, Yu J, et al. Immunogenicity of COVID-19 mRNA Vaccines in Pregnant and Lactating Women. JAMA. 06 15 2021;325(23):2370–2380. doi: 10.1001/jama.2021.7563 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Klein SL, Pekosz A, Park HS, et al. Sex, age, and hospitalization drive antibody responses in a COVID-19 convalescent plasma donor population. J Clin Invest. 11 02 2020;130(11):6141–6150. doi: 10.1172/JCI142004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Premkumar L, Segovia-Chumbez B, Jadi R, et al. The receptor binding domain of the viral spike protein is an immunodominant and highly specific target of antibodies in SARS-CoV-2 patients. Sci Immunol. 06 11 2020;5(48)doi: 10.1126/sciimmunol.abc8413 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Salazar E, Kuchipudi SV, Christensen PA, et al. Convalescent plasma anti-SARS-CoV-2 spike protein ectodomain and receptor-binding domain IgG correlate with virus neutralization. J Clin Invest. 12 01 2020;130(12):6728–6738. doi: 10.1172/JCI141206 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Seegmiller JC, Kokaisel EL, Story SJ, et al. Method comparison of SARS-CoV-2 serology assays involving three commercially available platforms and a novel in-house developed enzyme-linked immunosorbent assay. Clin Biochem. Dec 2020;86:34–35. doi: 10.1016/j.clinbiochem.2020.08.004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Stadlbauer D, Amanat F, Chromikova V, et al. SARS-CoV-2 Seroconversion in Humans: A Detailed Protocol for a Serological Assay, Antigen Production, and Test Setup. Curr Protoc Microbiol. 06 2020;57(1):e100. doi: 10.1002/cpmc.100 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Stadlbauer D, Tan J, Jiang K, et al. Repeated cross-sectional sero-monitoring of SARS-CoV-2 in New York City. Nature. 02 2021;590(7844):146–150. doi: 10.1038/s41586-020-2912-6 [DOI] [PubMed] [Google Scholar]
  • 21.Suthar MS, Zimmerman MG, Kauffman RC, et al. Rapid Generation of Neutralizing Antibody Responses in COVID-19 Patients. Cell Rep Med. Jun 23 2020;1(3):100040. doi: 10.1016/j.xcrm.2020.100040 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Thomas SN, Altawallbeh G, Zaun CP, et al. Initial determination of COVID-19 seroprevalence among outpatients and healthcare workers in Minnesota using a novel SARS-CoV-2 total antibody ELISA. Clin Biochem. Apr 2021;90:15–22. doi: 10.1016/j.clinbiochem.2021.01.010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Vidal SJ, Collier AY, Yu J, et al. Correlates of Neutralization against SARS-CoV-2 Variants of Concern by Early Pandemic Sera. J Virol. 06 24 2021;95(14):e0040421. doi: 10.1128/JVI.00404-21 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Zeng C, Evans JP, Pearson R, et al. Neutralizing antibody against SARS-CoV-2 spike in COVID-19 patients, health care workers, and convalescent plasma donors. JCI Insight. 11 19 2020;5(22)doi: 10.1172/jci.insight.143213 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Sariol CAA, Pantoja P, Serrano-Collazo C, et al. Function Is More Reliable than Quantity to Follow Up the Humoral Response to the Receptor-Binding Domain of SARS-CoV-2-Spike Protein after Natural Infection or COVID-19 Vaccination. Viruses. 09 30 2021;13(10)doi: 10.3390/v13101972 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Roy V, Fischinger S, Atyeo C, et al. SARS-CoV-2-specific ELISA development. J Immunol Methods. 2020 Sep - Oct 2020;484–485:112832. doi: 10.1016/j.jim.2020.112832 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Rosenberg ES, Tesoriero JM, Rosenthal EM, et al. Cumulative incidence and diagnosis of SARSCoV-2 infection in New York. Ann Epidemiol. 08 2020;48:23–29.e4. doi: 10.1016/j.annepidem.2020.06.004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Styer LM, Hoen R, Rock J, et al. High-Throughput Multiplex SARS-CoV-2 IgG Microsphere Immunoassay for Dried Blood Spots: A Public Health Strategy for Enhanced Serosurvey Capacity. Microbiol Spectr. 09 03 2021;9(1):e0013421. doi: 10.1128/Spectrum.00134-21 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Lee WT, Girardin RC, Dupuis AP, et al. Neutralizing Antibody Responses in COVID-19 Convalescent Sera. J Infect Dis. 01 04 2021;223(1):47–55. doi: 10.1093/infdis/jiaa673 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Yates JL, Ehrbar DJ, Hunt DT, et al. Serological analysis reveals an imbalanced IgG subclass composition associated with COVID-19 disease severity. Cell Rep Med. Jul 20 2021;2(7):100329. doi: 10.1016/j.xcrm.2021.100329 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Pisanic N, Randad PR, Kruczynski K, et al. COVID-19 Serology at Population Scale: SARS-CoV-2-Specific Antibody Responses in Saliva. J Clin Microbiol. 12 17 2020;59(1)doi: 10.1128/JCM.02204-20 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Canaday DH, Carias L, Oyebanji OA, et al. Reduced BNT162b2 mRNA vaccine response in SARSCoV-2-naive nursing home residents. Clin Infect Dis. May 16 2021;doi: 10.1093/cid/ciab447 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Tian L, Elsheikh EB, Patrone PN, et al. Towards Quantitative and Standardized Serological and Neutralization Assays for COVID-19. Int J Mol Sci. Mar 08 2021;22(5)doi: 10.3390/ijms22052723 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Su Y, Chen D, Yuan D, et al. Multi-Omics Resolves a Sharp Disease-State Shift between Mild and Moderate COVID-19. Cell. 12 10 2020;183(6):1479–1495.e20. doi: 10.1016/j.cell.2020.10.037 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Xhangolli I, Dura B, Lee G, Kim D, Xiao Y, Fan R. Single-cell Analysis of CAR-T Cell Activation Reveals A Mixed T. Genomics Proteomics Bioinformatics. 04 2019;17(2):129–139. doi: 10.1016/j.gpb.2019.03.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Heaney CD, Pisanic N, Randad PR, et al. Comparative performance of multiplex salivary and commercially available serologic assays to detect SARS-CoV-2 IgG and neutralization titers. J Clin Virol. 12 2021;145:104997. doi: 10.1016/j.jcv.2021.104997 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Haddad NS, Nguyen DC, Kuruvilla ME, et al. One-Stop Serum Assay Identifies COVID-19 Disease Severity and Vaccination Responses. Immunohorizons. 05 17 2021;5(5):322–335. doi: 10.4049/immunohorizons.2100011 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Amanat F, White KM, Miorin L, et al. An In Vitro Microneutralization Assay for SARS-CoV-2 Serology and Drug Screening. Curr Protoc Microbiol. 09 2020;58(1):e108. doi: 10.1002/cpmc.108 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Wajnberg A, Amanat F, Firpo A, et al. Robust neutralizing antibodies to SARS-CoV-2 infection persist for months. Science. 12 04 2020;370(6521):1227–1230. doi: 10.1126/science.abd7728 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Hassert M, Geerling E, Stone ET, et al. mRNA induced expression of human angiotensin-converting enzyme 2 in mice for the study of the adaptive immune response to severe acute respiratory syndrome coronavirus 2. PLoS Pathog. 12 2020;16(12):e1009163. doi: 10.1371/journal.ppat.1009163 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Vanderheiden A, Edara VV, Floyd K, et al. Development of a Rapid Focus Reduction Neutralization Test Assay for Measuring SARS-CoV-2 Neutralizing Antibodies. Curr Protoc Immunol. 12 2020;131(1):e116. doi: 10.1002/cpim.116 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Girardin RC, Dupuis AP, Payne AF, et al. Temporal Analysis of Serial Donations Reveals Decrease in Neutralizing Capacity and Justifies Revised Qualifying Criteria for Coronavirus Disease 2019 Convalescent Plasma. J Infect Dis. 03 03 2021;223(5):743–751. doi: 10.1093/infdis/jiaa803 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Dhakal S, Ruiz-Bedoya CA, Zhou R, et al. Sex Differences in Lung Imaging and SARS-CoV-2 Antibody Responses in a COVID-19 Golden Syrian Hamster Model. mBio. 08 31 2021;12(4):e0097421. doi: 10.1128/mBio.00974-21 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Morgenlander WR, Henson SN, Monaco DR, et al. Antibody responses to endemic coronaviruses modulate COVID-19 convalescent plasma functionality. J Clin Invest. 04 01 2021;131(7)doi: 10.1172/JCI146927 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Ogega CO, Skinner NE, Blair PW, et al. Durable SARS-CoV-2 B cell immunity after mild or severe disease. J Clin Invest. 04 01 2021;131(7)doi: 10.1172/JCI145516 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Kared H, Redd AD, Bloch EM, et al. SARS-CoV-2-specific CD8+ T cell responses in convalescent COVID-19 individuals. J Clin Invest. 03 01 2021;131(5)doi: 10.1172/JCI145476 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Patel EU, Bloch EM, Clarke W, et al. Comparative Performance of Five Commercially Available Serologic Assays To Detect Antibodies to SARS-CoV-2 and Identify Individuals with High Neutralizing Titers. J Clin Microbiol. 01 21 2021;59(2)doi: 10.1128/JCM.02257-20 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Röltgen K, Nielsen SCA, Arunachalam PS, et al. mRNA vaccination compared to infection elicits an IgG-predominant response with greater SARS-CoV-2 specificity and similar decrease in variant spike recognition. medRxiv. Apr 07 2021;doi: 10.1101/2021.04.05.21254952 [DOI] [Google Scholar]
  • 49.Pegu A, O’Connell S, Schmidt SD, et al. Durability of mRNA-1273-induced antibodies against SARS-CoV-2 variants. bioRxiv. May 16 2021;doi: 10.1101/2021.05.13.444010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Weissman D, Alameh MG, de Silva T, et al. D614G Spike Mutation Increases SARS CoV-2 Susceptibility to Neutralization. Cell Host Microbe. 01 13 2021;29(1):23–31.e4. doi: 10.1016/j.chom.2020.11.012 [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from medRxiv are provided here courtesy of Cold Spring Harbor Laboratory Preprints

RESOURCES