Abstract
To assess the multicenter clinical outcomes of the implantation of hole implantable collamer lens (Hole ICL, ICL KS-AquaPORTTM; STAAR Surgical, Nidau, Switzerland) in patients of 45 years or more. We retrospectively assessed the surgery’s safety, efficacy, predictability, stability, and adverse events before surgery and after the surgery at 1 week; 1, 3, and 6 months; and 1 year, followed by once every year for approximately 2.2 years. A total of 118 eyes of 65 patients aged 45–65 years with myopic refractive errors ranging from − 2.13 to − 18.75 diopters (D) underwent hole ICL implantation and routine postoperative examinations. The average observation period was 2.2 ± 1.0 years. The safety and efficacy indices were 1.08 ± 0.21 and 0.87 ± 0.25, respectively. Manifest refraction changes of − 0.20 ± 0.43 D occurred from 1 month to the final visit after ICL implantation. Eight eyes (6.8%) developed asymptomatic anterior subcapsular cataract (ASC) immediately after surgery, and three eyes (2.5%) developed clinically significant symptomatic nuclear cataracts during the follow-up period. According to our experience, hole ICL implantation offered favorable outcomes in all measures of safety, efficacy, predictability, and stability, even in middle-aged patients, during the 2.2-year observation period.
Subject terms: Health care, Quality of life, Medical research, Outcomes research
Introduction
The posterior chamber phakic intraocular implantable collamer lens (ICL) with a central port (Hole ICL, ICL KS-AquaPORT, STAAR Surgical, Nidau, Switzerland) was first implanted by Kimiya Shimizu in 20071, and the number of ICL surgeries has significantly increased since then due to improved safety. The conventional ICL (before V4 models) had two major problems: (1) Iridectomy was required because the ICL interfered with the intraocular aqueous circulation, and if the iridectomy was incomplete, pupillary block occurred in rare cases2. (2) Risk of metabolic cataract progression due to poor circulation of aqueous humor, particularly in cases with low vault (< 230 μm)3, high levels of myopia4, and an advanced age (over 40 years old)4.
When compared to conventional ICLs (V4 and earlier models), hole ICL has a 0.36-mm hole in the center of the lens, which is designed to allow the aqueous humor in the eye to circulate naturally. Therefore, the abovementioned complications of conventional ICL have significantly improved5. Due to the risk of cataracts and presbyopia in conventional ICL, the surgical indication for ICL in Japan is 21–45 years of age. However, there are patients aged over 45 years who wish to undergo ICL surgery. Since the extended depth of focus ICL (EVO Viva, STAAR Surgical, Nidau, Switzerland) also obtained the CE mark in July 2020, it is expected that the number of patients aged ≥ 45 years will be increasing further in the future. Therefore, in this multicenter study, we evaluated the safety and efficacy of the clinical outcomes after hole ICL implantation in patients aged ≥ 45 years in Japan.
Results
Study population
Preoperative patient demographics are summarized in Table 1. All patients were followed up for more than 1 year, and the observation period was 2.2 ± 1.0 years (range 1–3 years).
Table 1.
Characteristic | Mean ± SD |
---|---|
Observation period (years) | 2.2 ± 1.0 years (range 1 to 3 years) |
Age (years) | 48.9 ± 4.2 years (range 45 to 65 years) |
Gender (% female) | 47.5% |
Manifest spherical equivalent (D) | − 9.15 ± 3.59 D (range − 2.13 to − 18.75 D) |
Manifest cylinder (D) | 1.11 ± 1.25 D (range 0.00 to 6.00 D) |
Log MAR UDVA | 1.41 ± 0.26 (range 0.52 to 2.00 ) |
Log MAR CDVA | − 0.15 ± 0.10 (range − 0.30 to 0.22 ) |
White-to-white distance (mm) | 11.7 ± 0.4 mm (range 10.9 to 12.8 mm) |
Anterior chamber depth (mm) | 2.99 ± 0.27 mm (range 2.51 to 4.19 mm) |
Mean keratometric readings (D) | 43.9 ± 1.4 D (range 39.6 to 47.1 D) |
Central cornea thickness (μm) | 541 ± 39 μm (range 452 to 651 μm) |
Intraocular pressure (mmHg) | 13.6 ± 2.5 mmHg (range 8 to 21 mmHg) |
Endothelial cell density (cells/mm2) | 2752 ± 263 cells/mm2 (range 2153 to 3401 cells/mm2) |
Log MAR logarithm of the minimal angle of resolution, UDVA uncorrected distance visual acuity, CDVA corrected distance visual acuity.
Safety outcomes
The log MAR CDVA at 1 week, 1 month, 3 months, 1 year, and the final visit (average: 2.2 years) after surgery was − 0.18 ± 0.08, − 0.18 ± 0.09, − 0.18 ± 0.10, − 0.017 ± 0.09, and 0.17 ± 0.09, respectively. The safety index (mean postoperative CDVA/ mean preoperative CDVA) at 1 week, 1 month, 3 months, 1 year, and the final visit after surgery was 1.10 ± 0.24, 1.10 ± 0.23, 1.11 ± 0.22, 1.08 ± 0.22, and 1.08 ± 0.21, respectively. At the final visit, 62 eyes (52.5%) showed no change in CDVA, 38 eyes (32.2%) gained one line, 1 eye (0.8%) gained two lines, 17 eyes (14.4%) lost one line, and no eye (0%) lost two or more lines.
Effectiveness outcomes
To evaluate the efficacy of the procedure, we evaluated eyes in which the target refraction was emmetropia (N = 73 eyes). The log MAR UDVA at 1 week, 1 month, 3 months, 1 year, and the final visit (average: 2.2 years) after surgery was − 0.10 ± 0.18, − 0.10 ± 0.17, − 0.10 ± 0.17, − 0.09 ± 0.16, and − 0.07 ± 0.17, respectively. The efficacy index (mean postoperative UDVA/ mean preoperative CDVA) was 0.95 ± 0.29, 0.94 ± 0.28, 0.93 ± 0.28, 0.91 ± 0.26, and 0.87 ± 0.25 at 1 week, 1 month, 3 months, 1 year, and the final visit after surgery, respectively. At 1 week, 1 month, 3 months, 1 year, and the final visit after surgery, 96%, 97%, 96%, 96%, and 96% of eyes, respectively, had UDVAs of 20/40 or better, and 90%, 88%, 90%, 89%, and 86% of eyes, respectively, had UDVAs of 20/20 or better.
Predictability
At 1 week, 1 month, 3 months, 1 year, and the final visit (average: 2.2 years) after surgery, 80%, 82%, 83%, 80%, and 78% of eyes, respectively, were within ± 0.5 D, and 94%, 96%, 93%, 97%, and 93% of eyes, respectively, were within ± 1.0 D of the attempted correction (Fig. 1).
Stability
At 1 week, 1 month, 3 months, 1 year, and the final visit (average: 2.2 years) after surgery, the mean manifest spherical equivalent was − 0.35 ± 0.69, − 0.40 ± 0.65, − 0.37 ± 0.68, − 0.48 ± 0.68, and − 0.61 ± 0.71 D, respectively (ANOVA, p = 0.03). Multiple comparisons revealed significant differences between measurements made at 1 week after surgery and at the final visit after surgery (Tukey–Kramer test, p = 0.03). The changes in manifest refraction from 1 month to 1 year and from 1 month to the final visit were − 0.06 ± 0.31 and − 0.20 ± 0.43 D, respectively.
Intraocular pressure
The IOP showed no significant change from 13.6 ± 2.5 mmHg before the surgery to 14.1 ± 3.2, 13.4 ± 2.4, 13.4 ± 2.6, 13.9 ± 2.8, and 13.9 ± 3.1 mmHg at 1 week, 1 month, 3 months, 1 year, and the final visit (average: 2.2 years) after surgery, respectively (ANOVA, p = 0.21). No significant increase in IOP occurred in any case during the observation period.
Endothelial cell density
The endothelial cell density significantly decreased from 2752 ± 263cells/mm2 preoperatively to 2700 ± 260 cells/mm2 at the final visit (average: 2.2 years) postoperatively (Paired t-test, p = 0.01). The mean percentage of endothelial cell loss was1.6 ± 8.1% (range from − 28.0 to + 25.6%) at the final visit (2.2 years postoperatively).
Secondary surgeries/adverse events
There were no intraoperative complications, and all implantations were uneventful. Of the 118 eyes examined, 8 eyes (6.8%) developed asymptomatic anterior subcapsular cataract (ASC), but all eyes had a CDVA of 20/20 or better (Table 2). In most cases, ASCs occurred immediately after surgery. Case 1 developed ASC immediately after ICL exchange due to an excessive high vault. ASC occurred under the hole position of the ICL (Fig. 2), possibly due to the excessive suction of the ophthalmic viscosurgical device between the ICL and the crystalline lens through this hole using an irrigation and aspiration tip. The ASC may have been caused due to the contact between the ICL and the anterior surface of the lens during irrigation and aspiration. However, the ASC did not progress thereafter. Only three eyes (2.5%) developed clinically significant nuclear cataracts postoperatively, and these patients complained of poor visibility (double vision and myopic change) (Fig. 3). Simultaneous lens extraction and phacoemulsification with intraocular lens (IOL) implantation were successfully performed in these three eyes, and the patients had improved vision and no other complaints after the surgery. All eyes had high myopia (long axial length) (Table 3). In Table 3, Case 1 underwent binocular cataract surgery with a difference of a few years. The left eye in Case 2 was not indicated for ICL implantation because of a previous history of optic neuritis and poor corrected visual acuity. Subsequently, Case 2 underwent cataract surgery in both eyes at the same time. Of the 46 cases in which toric ICL was used, deteriorating UDVA, changing refraction, or an axis rotation of 10° or more occurred in two eyes (4.3%) postoperatively, which required ICL repositioning. Three eyes (2.5%) underwent ICL exchange due to excessive high vault. No pigment dispersion glaucoma, pupillary block, or any other vision-threatening complications were seen throughout the follow-up period. Table 4 shows the clinical outcomes based on each target refractive power. The results were divided into three target refractive power categories, with no significant differences in the safety and the predictability metrics.
Table 2.
Case 1 | Case 2 | Case 3 | Case 4 | Case 5 | Case 6 | |||
---|---|---|---|---|---|---|---|---|
Right eye | Left eye | Left eye | Left eye | Right eye | Right eye | Left eye | Right eye | |
Age | 50 | 50 | 59 | 54 | 46 | 53 | 53 | 47 |
Gender | Female | Female | Female | Female | Female | Male | Male | Male |
Time of onset | Immediately after surgery (ICL exchange) | Immediately after surgery (ICL exchange) | Immediately after surgery | Immediately after surgery | Immediately after surgery | Immediately after surgery | Immediately after surgery | Post-Op 6 months |
Pre. SE (D) | − 6.1 | − 6.5 | − 18.3 | − 11.6 | − 14.8 | − 16.0 | − 12.5 | − 13.3 |
Pre. CDVA | 30/20 | 30/20 | 20/20 | 12/20 | 40/20 | 24/20 | 20/20 | 24/20 |
CDVA (Final Visit) | 20/20 (2 years) | 20/13 (2 years) | 20/16 (1 year) | 20/25 (1 year) | 20/13 (3 years) | 20/16 (2 years) | 20/16 (2 years) | 20/13 (3 years) |
Vault (CT) | 0.6 | 0.4 | 0.6 | 0.7 | 1.0 | 0.5 | 0.3 | 0.6 |
SE spherical equivalent, CDVA corrected distance visual acuity, CT corneal thickness.
Table 3.
Case 1 | Case 2 | ||
---|---|---|---|
Right eye | Left eye | Right eye | |
Age | 46 | 46 | 52 |
Gender | Male | Male | Female |
Pre. CDVA | 40/20 | 30/20 | 24/20 |
Pre. SE (D) | − 12.3 | − 13.0 | − 11.8 |
Pre. vault (CT) | 0.7 | 1.3 | 1.1 |
Pre. axial length (mm) | 30.1 | 30.2 | 27.5 |
Time to cataract surgery | 4.3 years | 2.1 years | 2.9 years |
CDVA (final visit) | 24/20 | 20/20 | 20/20 |
SE (D) | − 0.25D | − 2.50D | − 1.75D |
Types of cataracts | Nuclear | Nuclear | Nuclear |
CDVA corrected distance visual acuity, SE spherical equivalent, CT corneal thickness.
Table 4.
Pre-UDVA | Pre-CDVA | Pre-SE (D) | Target ref (D) | Post-UDVA | Safety index | Efficacy index | Post-SE (D) | Predictability (± 1.0D) | |
---|---|---|---|---|---|---|---|---|---|
Bilateral Emmetropia (N = 54eyes) | 1.38 ± 0.27 | − 0.15 ± 0.11 | − 9.14 ± 3.70 | − 0.10 ± 0.19 | − 0.07 ± 0.18 | 1.11 ± 0.22 | 0.88 ± 0.26 | − 0.40 ± 0.57 | 93% |
Monovision (N = 26eyes DE:13/NDE:13) | DE 1.37 ± 0.22 NDE: 1.44 ± 0.24 | DE: − 0.16 ± 0.06 NDE: − 0.16 ± 0.07 | DE: − 8.05 ± 3.65 NDE: − 8.55 ± 3.84 | DE: − 0.31 ± 0.24 NDE: − 1.14 ± 0.41 | DE: − 0.03 ± 0.21 NDE: 0.21 ± 0.32 | DE: 1.09 ± 0.17 NDE: 1.06 ± 0.18 | DE: 0.80 ± 0.24 NDE: 0.52 ± 0.30 | DE: − 0.37 ± 0.42 NDE: − 1.10 ± 0.73 | DE: 100% NDE: 100% |
Bilateral Intentional-Undercorrection (N = 26eyes) | 1.46 ± 0.20 | − 0.16 ± 0.09 | − 10.17 ± 2.94 | − 0.78 ± 0.33 | 0.08 ± 0.22 | 1.02 ± 0.20 | 0.65 ± 0.29 | − 0.80 ± 0.63 | 92% |
UDVA uncorrected distance visual acuity, CDVA corrected distance visual acuity, SE spherical equivalent, DE dominant eye, NDE non-dominant eye.
Discussion
In this multicenter study, we confirmed excellent results in all measures of safety, efficacy, predictability, and stability of hole ICL implantation in patients older than 45 years throughout the follow-up period of 1 year or more.
Conventional ICLs (before V4 models) have been reported to have good long-term clinical outcomes9–12. However, conventional ICL has two drawbacks. One is the need for iridectomy, and the other is the progression of ASC after ICL implantation. Inappropriate iridectomy rarely resulted in pupillary block2. The incidence of ASC ranged from 1.1 to 5.9%5, and the probability of requiring cataract surgery for vision loss ranged from 0 to 1.8%5. The risk of cataract progression was particularly high in patients with an advanced age (over 40 years old)4, high myopia (less than − 12.0 D)4, and low vault (< 230 μm)3. However, with the advent of the hole ICL, these risks have been greatly reduced and safety has been improved13.
A meta-analysis of hole ICL13 reported a safety index of 1.15 (range: 1.01–1.42, average follow-up period: 13.2 months) and that only 0.2% of eyes lost two or more lines of CDVA, while 95.5% maintained or gained lines of CDVA; the change in CDVA before and after surgery was also good. To date, only one case of pupillary block has been reported after hole ICL implantation14, but this case was unique in that the central port of the ICL was blocked with viscoelastic and inflammatory debris. Visually significant cataract has not been reported in patients implanted with hole ICL13. The incidence of asymptomatic ASC opacities was 0.49%, but none of the reports had any cases of ICL removal and cataract surgery because of vision loss13.
In this multicenter study, the patients were aged 45 years or older and were at a high risk of developing cataract with conventional ICL4. There are only a few reports6–8 on the postoperative outcomes after hole ICL implantation in middle-aged and older patients, which are summarized in Table 5. All previous reports6–8 had short observation periods and small sample sizes. In this study, the mean observation period was 2.2 years (cases with more than 1 year of follow-up), and the safety index was 1.08. None of the eyes lost two or more lines of CDVA, and 85.6% maintained or gained lines of CDVA. This multicenter study demonstrated a 6.8% (8/118) incidence of secondary surgical intervention with an average follow-up period of 2.2 years. Two eyes required rotation of a toric ICL, and three eyes exchanged the ICL due to excessive high vault (> 1000 μm). Three eyes (2.5%) developed clinically significant nuclear cataracts postoperatively, and simultaneous lens extraction and phacoemulsification with IOL implantation were successfully performed. These three eyes also had preoperative mild cataracts of G1.5 to G2 (Emery–Little classification). All cases of nuclear cataract had CDVA > 20/20, but cataract surgery was performed due to decreased UDVA. The prediction of IOL power for cataract surgery in ICL implanted eyes is good15, and the patients are also satisfied with their vision. All patients with nuclear cataracts in this study had high myopia with an axial length of ≥ 27.5 mm, which may have influenced the results16.
Table 5.
Author | Observation period (number of cases) | Age (min, max) | UDVA (log MAR) | CDVA (log MAR) | ± 1.0D (% of eyes) | Post.op SE (D) | ECD (cells/mm2) (% of loss) | Cataract |
---|---|---|---|---|---|---|---|---|
Tañá-Rivero et al.6 | 1 year (33 eyes) | 43.5 ± 4.5 (40, 56) | 0.88 ± 0.16 (decimal) | 0.96 ± 0.09 (decimal) | 93.9 | − 0.09 ± 0.47 | 2516 ± 234 (2.04) | 0% |
Kamiya et al.7 | 6 months (34 eyes) | 46.1 ± 4.2 (40, 53) | − 0.04 ± 0.18 | − 0.19 ± 0.09 | 100 |
DE: − 0.08 ± 0.17 NDE: − 0.65 ± 0.29 |
– | 0% |
Takahashi et al.8 | 6 months (42 eyes) | 45.0 ± 3.8 (40, 53) | − 0.03 ± 0.20 | − 0.19 ± 0.08 | 100 | – | – | 0% |
Current study | 2.2 years (118 eyes) | 48.9 ± 4.2 (45, 65) | − 0.07 ± 0.17 | − 0.17 ± 0.09 | 93 | − 0.61 ± 0.71 | 2700 ± 260 (1.6) |
6.8%: Asymptomatic ASC cases 2.5%: Symptomatic NC cases |
UDVA uncorrected distance visual acuity, CDVA corrected distance visual acuity, SE spherical equivalent, endothelial cell density, DE dominant eye, NDE non-dominant eye, ASC anterior subcapsular cataract, NC nuclear cataract, Log MAR logarithm of the minimal angle of resolution.
Asymptomatic ASC opacities occurred in 6.8% (8/118) of cases. This is a high rate compared to previous reports17–19, but seven eyes developed ASC opacities immediately after surgery. In these cases, the ASC was localized just below the central port of the lens, suggesting that it was caused by an intraoperative irrigation technique. The suction hole was vigorously directed toward the central hole during irrigation and aspiration, and we thought that the ASC was caused by the contact of the anterior surface of the lens with the posterior surface of the ICL during aspiration. Steinwender et al.20 reported similar cases and noted that after changing the surgical technique to a very gentle irrigation and keeping the cannula near the main incision, more than 90 phakic IOL implantations were performed in the clinic during a follow-up period of 14 months, with no further occurrence of ASC. This may imply that ASC can easily occur by mechanical contact with the lens in older patients, since no ASCs have been observed in young patients using this technique. In this study, patients with asymptomatic ASC opacities did not have ASC progression or CDVA decline and did not require additional surgery.
As a limitation to this study, we believe that a longer follow-up is necessary. In addition, we could not measure the objective postoperative vault because not all hospitals had anterior segment optical coherence tomography. Further, we included some cases with shallow anterior chamber depth (> 2.5 mm) based on previous reports21. In the future, we believe that a more detailed investigation of the relationship between ICL size and postoperative complications is desirable.
In conclusion, this multicenter study supports the view that hole ICL implantation offered good results in all measures of safety, efficacy, predictability, and stability in patients over 45 years old during the 2.2-year observation period. However, we must be careful of mechanical lens contact associated with intraoperative manipulation in older patients. In addition, since nuclear cataracts may occur with aging in patients with severe myopia, prior explanation is important. The number of ICL surgeries in middle-aged and elderly patients is expected to increase in the future, and we hope that the results of this study will be of help to these patients.
Methods
This was a multicenter study performed at Kitasato University, Nagoya Eye Clinic, Sapia Tower Eye Clinic, and Sanno Hospital in Japan. A total of 118 eyes of 65 consecutive patients (males: 62eyes and females: 56 eyes) who underwent implantation of hole ICL for the correction of myopia and myopic astigmatism and regularly returned for postoperative examination were included in this retrospective observational study. In this study, 106 eyes of 53 patients were operated on both eyes, and 12 eyes were operated on only one eye. The inclusion criteria for this surgical technique were as follows: unsatisfactory correction with spectacles or contact lenses, ≥ 45 years of age, stable refraction for at least 6 months, myopia ranging from − 2.0 to − 20.0 diopters (D), anterior chamber depth ≥ 2.5 mm, endothelial cell density ≥ 2000 cells/mm2, no history of ocular surgery, progressive corneal degeneration, cataract, glaucoma or uveitis, and follow-up of ≥ 1 year. Eyes with keratoconus were excluded from the study by using the keratoconus screening test of Placido disk videokeratography (TMS-2, Tomey, Nagoya, Japan). Before surgery, the horizontal white-to-white distance and anterior chamber depth (from the corneal endothelium to the anterior surface of the lens) were measured using a scanning-slit topograph (Orbscan IIz, Bausch & Lomb, Rochester, US), and the axial length was measured using partial coherence laser interferometry (IOL Master; Carl Zeiss AG, Oberkochen, Germany). Before surgery and 1 day; 1 week; 1, 3, and 6 months; and 1, 2, and 3 years after surgery, we determined the following: logarithm of the minimal angle of resolution (log MAR) of uncorrected distance visual acuity (UDVA), log MAR of corrected distance visual acuity (CDVA), manifest refraction (spherical equivalent), intraocular pressure (IOP), endothelial cell density, mean keratometric reading, and axial length, in addition to the usual slit-lamp biomicroscopic and fundoscopic examinations. The size of ICL was selected based on the nomogram provided by the manufacturer (STAAR Surgical).
The study was approved by the Institutional Review Board of International University of Health and Welfare (21-S-10) and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all patients after explanation of the nature and possible consequences of the study.
Implantable collamer lens power calculation
ICL power calculation was performed by the manufacturer (STAAR Surgical) using a modified vertex formula. In this study, we set the target refractive power taking presbyopia into account, as described previously6–8. The target refractive power was emmetropia in 50.9% (54/106), monovision in 24.5% (26/106), and intentional under-correction in 24.5% (26/106). The target refractive power was individually determined by contact lens simulation and the patient's lifestyle. These groupings by the target refractive power were individually performed by each case in which both eyes were operated.
Implantable collamer lens surgical procedure
All ICL implantation surgeries were performed using a standardized method in all surgical centers. After topical anesthesia, ICL was inserted through a 3-mm clear corneal incision using an injector cartridge (STAAR Surgical) after placement of a viscosurgical device (Opegan; Santen, Osaka, Japan) into the anterior chamber. The ICL was placed in the posterior chamber, the viscosurgical device was completely washed out of the anterior chamber with a balanced salt solution, and a myotic agent was instilled. All surgeries were uneventful, and no intraoperative complication was observed. After surgery, steroids (0.1% betamethasone; Rinderon; Shionogi, Osaka, Japan) and antibiotics (0.3% levofloxacin; Cravit; Santen, Osaka, Japan) were topically administered four times daily for two weeks, and the dose was gradually reduced thereafter.
Statistical analysis
All statistical analyses were performed using StatView version 5.0 (SAS, Cary, NC, USA). One-way analysis of variance (ANOVA) was used to analyze the time course of changes, along with the Tukey–Kramer test for multiple comparisons. The paired t-test was used to compare the pre- and post-surgical data. The Pearson correlation coefficient was used to assess the correlation between the changes in manifest spherical equivalent and axial length. The results are expressed as mean ± standard deviation, and a value of p < 0.05 was considered statistically significant.
Author contributions
All authors compiled the data from each institution and prepared the paper in A.I. and K.K. Finally, K.S. supervised the paper.
Competing interests
Dr. Shimizu is a consultant to STAAR Surgical. The remaining authors indicate no financial conflict of interest.
Footnotes
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Shimizu K, Kamiya K, Igarashi A, Shiratani T. Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia. Br. J. Ophthalmol. 2012;96(3):409–412. doi: 10.1136/bjophthalmol-2011-300148. [DOI] [PubMed] [Google Scholar]
- 2.Bylsma SS, Zalta AH, Foley E, Osher RH. Phakic posterior chamber intraocular lens pupillary block. J. Cataract. Refract. Surg. 2002;28(12):2222–2228. doi: 10.1016/S0886-3350(02)01303-2. [DOI] [PubMed] [Google Scholar]
- 3.Schmidinger G, Lackner B, Pieh S, Skorpik C. Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients. Ophthalmology. 2010;117(8):1506–1511. doi: 10.1016/j.ophtha.2009.12.013. [DOI] [PubMed] [Google Scholar]
- 4.Sanders DR. Anterior subcapsular opacities and cataracts 5 years after surgery in the visian implantable collamer lens FDA trial. J. Refract. Surg. 2008;24(6):566–570. doi: 10.3928/1081597X-20080601-04. [DOI] [PubMed] [Google Scholar]
- 5.Packer M. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens. Clin. Ophthalmol. 2016;10:1059–1077. doi: 10.2147/OPTH.S111620. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Tañá-Rivero P, Pastor-Pascual F, Crespo M, Rodríguez-Prats JL, Muñoz-Tomás JJ, Montés-Micó R. Posterior-chamber phakic intraocular lens implantation in patients over 40 years of age. J. Ophthalmol. 2020;2020(29):7457902. doi: 10.1155/2020/7457902. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Kamiya K, Takahashi M, Takahashi N, Shoji N, Shimizu K. Monovision by implantation of posterior chamber phakic intraocular lens with a central hole (hole ICL) for early presbyopia. Sci. Rep. 2017;7(1):11302. doi: 10.1038/s41598-017-11539-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Takahashi M, Kamiya K, Shoji N, Kato S, Igarashi A, Shimizu K. Intentional undercorrection by implantation of posterior chamber phakic intraocular lens with A central hole (hole ICL) for early presbyopia. Biomed. Res. Int. 2018;2018:6158520. doi: 10.1155/2018/6158520. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Moya T, Javaloy J, Montés-Micó R, Beltrán J, Muñoz G, Montalbán R. Implantable collamer lens for myopia: assessment 12 years after implantation. J. Refract. Surg. 2015;31(8):548–556. doi: 10.3928/1081597X-20150727-05. [DOI] [PubMed] [Google Scholar]
- 10.Igarashi A, Shimizu K, Kamiya K. Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Am. J. Ophthalmol. 2014;157(3):532–539. doi: 10.1016/j.ajo.2013.11.006. [DOI] [PubMed] [Google Scholar]
- 11.Choi JH, Lim DH, Nam SW, Yang CM, Chung ES, Chung TY. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia. J. Cataract. Refract. Surg. 2019;45(11):1555–1561. doi: 10.1016/j.jcrs.2019.06.015. [DOI] [PubMed] [Google Scholar]
- 12.Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y. Posterior chamber phakic intraocular lens implantation for the correction of myopia and myopic astigmatism: a retrospective 10-year follow-up study. Am. J. Ophthalmol. 2019;206:1–10. doi: 10.1016/j.ajo.2019.04.024. [DOI] [PubMed] [Google Scholar]
- 13.Packer M. The implantable collamer lens with a central port: review of the literature. Clin. Ophthalmol. 2018;27(12):2427–2438. doi: 10.2147/OPTH.S188785. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Senthil S, Choudhari NS, Vaddavalli PK, Murthy S, Reddy JC, Garudadri CS. Etiology and management of raised intraocular pressure following posterior chamber phakic intraocular lens implantation in myopic eyes. PLoS ONE. 2016;11(11):e0165469. doi: 10.1371/journal.pone.0165469. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Kamiya K, Shimizu K, Igarashi A, Aizawa D, Ikeda T. Clinical outcomes and patient satisfaction after Visian Implantable Collamer Lens removal and phacoemulsification with intraocular lens implantation in eyes with induced cataract. Eye (London) 2010;24(2):304–309. doi: 10.1038/eye.2009.87. [DOI] [PubMed] [Google Scholar]
- 16.Haarman AEG, Enthoven CA, Tideman JWL, Tedja MS, Verhoeven VJM, Klaver CCW. The complications of myopia: a review and meta-analysis. Investig. Ophthalmol. Vis. Sci. 2020;61(4):49. doi: 10.1167/iovs.61.4.49. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Shimizu K, Kamiya K, Igarashi A, Kobashi H. Long-term comparison of posterior chamber phakic intraocular lens with and without a central hole (hole ICL and conventional ICL) implantation for moderate to high myopia and myopic astigmatism: consort-compliant article. Medicine (Baltimore) 2016;95(14):e3270. doi: 10.1097/MD.0000000000003270. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Karandikar S, Bhandari V, Reddy J. Outcomes of implantable collamer lens V4 and V4c for correction of high myopia—a case series. Nepal. J. Ophthalmol. 2015;7(14):164–172. doi: 10.3126/nepjoph.v7i2.14967. [DOI] [PubMed] [Google Scholar]
- 19.Fernández-Vigo JI, Macarro-Merino A, Fernández-Vigo C, De-Pablo-Gómez-de-Liaño L, Fernández-Pérez C, García-Feijóo J, Fernández-Vigo JÁ. Impacts of implantable collamer lens V4c placement on angle measurements made by optical coherence tomography: two-year follow-up. Am. J. Ophthalmol. 2018;186:171–172. doi: 10.1016/j.ajo.2017.10.034. [DOI] [PubMed] [Google Scholar]
- 20.Steinwender G, Varna-Tigka K, Shajari M, Kohnen T. Anterior sub capsular cataract caused by forceful irrigation during implantation of a posterior chamber phakic intraocular lens with a central hole. J. Cataract. Refract. Surg. 2017;43(7):969–974. doi: 10.1016/j.jcrs.2017.03.045. [DOI] [PubMed] [Google Scholar]
- 21.Kamiya K, Shimizu K, Igarashi A, Kitazawa Y, Kojima T, Nakamura T, Ichikawa K. Posterior chamber phakic intraocular lens implantation in eyes with an anterior chamber depth of less than 3 mm: a multicenter study. Sci. Rep. 2018;8:13322. doi: 10.1038/s41598-018-31782-y. [DOI] [PMC free article] [PubMed] [Google Scholar]