Abstract
Background/Aim: Despite the popularity of contrast enhanced spectral mammography (CESM), univocal classification of the background parenchymal enhancement (BPE), a bilateral enhancement of the normal breast parenchyma after contrast administration, is lacking. The present study aimed to evaluate the application of BPE Breast Imaging Reporting and Data System Magnetic Resonance (BI-RADS-MR) score for the CESM BPE. Moreover, a pictorial review of four different cases with CESM is provided.
Patients and Methods: A single-center, retrospective study from a prospectively maintained database of all women undergoing digital mammography (DM) and CESM in our institution between 2016 and 2019. DM and CESM were classified by two experienced radiologists.
Results: No statistically significant difference between DM breast density and BPE CESM classification was found. Agreement between readers ranged from substantial to almost perfect.
Conclusion: BIRADS-RM score for the CESM BPE represents a handy option for radiologists with high inter-reader and DM agreement.
Keywords: Contrast enhanced spectral mammography, background parenchymal enhancement, breast imaging-reporting and data system, breast cancer, breast glandular density
Breast cancer (BC) is the leading cause of neoplasm affecting 2.1 million women per year worldwide (1). Despite the epidemiologic burden, deep knowledge of cancer biology, early detection and reduction of surgical impact have provided steady improvement in long term outcomes in the recent years (2-4).
In Europe, early detection has been provided through mammographic screening programs, which alone provided reduction in morbidity related with locally advanced breast cancer (LABC) diagnosis, and cancer-specific mortality between 12% and 58% (5,6), with reduction of locoregional lymph nodes involved (7,8) and distant metastasis (9,10).
However, during screening when mammography is not sufficient, additional second level imaging such as digital breast tomosynthesis, ultrasound, magnetic resonance (MR) and/or contrast enhanced spectral mammography (CESM) are required (11).
Within the last few years, CESM gained popularity as a diagnostic technique for BC detection. When compared with breast MR, CESM is a faster and cheaper technique, which is characterized by greater patients’ comfort (12). Additionally, it has also been proven that CESM has a very low learning curve for imaging specialists (13).
Thanks to these advantage, current CESM indication shifted from second level imaging alternative to MR in case of contraindication (e.g., patients with metallic prosthesis or claustrophobic) to evaluate inconclusive findings on mammography, and assess breast symptoms, cancer staging, and the response to neoadjuvant chemotherapy (12,14). Moreover, a recent use as an alternative examination to MR for high-risk screening has also been reported (13-15).
Regarding the method, CESM can be performed using two different techniques, temporal subtraction (between pre- and post-contrast acquisition) and dual-energy subtraction. The latter one combines an iodinated contrast agent with dual-energy subtraction technique, consisting of a pair of low-energy and high-energy images acquired after contrast administration and used to construct the final combined image (16).
Contrast agent administration, which is selectively concentrated in the tumor bed due to tumor tissue neo-angiogenesis, provides better neoplasm visualization compared to the traditional mammography (12).
However, CESM limitations consist of artefacts in patients with breast implants (17,18), the radiation dose associated with CESM, and the background parenchymal enhancement (BPE) phenomenon. BPE, previously described in RM, is a bilateral enhancement of the normal breast parenchyma after contrast administration, depending on tissue venous blood pool and its permeability to the contrast agent.
Despite the fact that the BPE phenomenon has already been studied and higher grade BPE has been associated with higher risk of BC (16), univocal BPE in CESM classification is lacking. Therefore, the aim of the present study was to assess a proposal of classification of BPE in CESM and a pictorial review of our case series.
Patients and Methods
Study design and patient selection. A single-center, retrospective study from a prospectively maintained database was designed. The local Institutional Review Board waived the need of a formal approval due to the retrospective design. Patients with higher risk of BC development according to the Gail Score (>15% lifetime risk) (19) were enrolled in our high risk screening program with mammography and CESM between 2016 and 2019. Before admission in the high-risk screening program, our patients routinely sign written informed consent for retrospective study. If digital mammography (DM) or CESM was not performed in our facility, patients were excluded from the analysis.
All exams were blindly evaluated by two experienced radiologists with 15 years of interpretation experience in mammography and five years in CESM, who are not routinely involved in our high-risk screening program.
DM was graded separately according to the breast imaging reporting and data system (BI-RADS) density classification as predominantly fatty (BIRADS 1), scattered fibroglandular (BIRADS 2), heterogeneously dense (BIRADS 3), or extremely dense (BIRADS 4) (20).
After evaluation of DM, blind evaluation of CESM was performed. BPE in CESM was firstly defined as absent or present. When BPE CESM was detected, BPE was classified as BI-RADS-RM score according to localization (symmetric or asymmetric) and amount [absent, grade 1 (minimal), grade 2 (mild), grade 3 (moderate) or grade 4 (marked)] (21).
When radiologists assigned different scores in DM evaluation, collegial discussions were performed in order to obtain unique CESM BPE classification and unique BPE CESM evaluation.
CESM protocol. In our clinical practice, DM is routinely performed with GE Healthcare Dual Energy Mammography System (Milan, Italy). Moreover, our high-risk screening protocol of CESM was performed with GE Healthcare Dual Energy Mammography System after intravenous administration of 1.5 ml of iohexol Omnipaque 350 (GE, Shanghai, PR China) per kilogram of body weight at an injection rate of 3 ml/s. Once the injection was completed, the patient was positioned to acquire the first mammographic image, which was obtained approximately 2.5 minutes after injection. All four images (craniocaudal and mediolateral oblique images of each breast) were obtained within 5 minutes. For each view, a low-energy exposure (26-30 kVp) and a high-energy exposure (45-49 kVp) were acquired. A recombination algorithm was used to subtract the unenhanced breast tissue and provided a subtracted image on which areas of contrast enhancement were highlighted. The low-energy exposure images were used to determine breast density. All four views were used for BPE evaluation.
Statistical analysis. All data were recorded onto an EXCEL database (Microsoft, Redmond, WA, USA). Dummy variables reported as numbers and percentages: Chi-squared and Fisher’s exact tests for statistical significance were performed. Variables with a p-value <0.05 were considered statistically significant.
A ĸ coefficient was calculated to assess pairwise agreement between each pairing of the two readers for categorization of BPE and assessment of overall agreement; the mean ĸ value was calculated from these pairs. Strength of ĸ agreement was defined as less than 0.00, poor; 0.00-0.20, slight; 0.21-0.40, fair; 0.41-0.60, moderate; 0.61-0.80, substantial; and 0.81-1.00, almost perfect.
Results
Among 170 patients, who performed CESM in the study period, 15 were excluded: five patients performed CESM as assessment of neoadjuvant chemotherapy response and 10 patients performed DM and CESM as postoperative follow-up. Consequently, the final cohort consisted of 155 patients.
Regarding the DM pattern, 65/155 (42%) were classified in BIRADS 1, 28/155 (18%) in BIRADS 2, 51/155 (33%) in BIRADS 3, and 11/155 (7%) in BIRADS 4. CESM BPE showed that 38/155 (25%) were BPE absent, 55/155 (35%) BPE grade 1, 30/155 (20%) BPE grade 2, 22/155 (14%) BPE grade 3, and 10/155 (6%) BPE grade 4. No statistically significant difference between DM breast density and CESM BPE was found (p>0.05).
Overall agreement for categorization of BPE among the readers ranged from substantial to almost perfect (ĸ=0.60-0.96) with a mean ĸ value of 0.743. As pictorial review, we present 4 examples of different BPE.
Clinical cases.
Case No 1: Contrast-enhanced spectral mammography characterized by minimal BPE. A 59-year-old woman was called back to our institute to perform CESM in order to investigate a palpable lump, located at the upper outer quadrant of the left breast, neither identified by DM nor by ultrasound examination (US). Breast composition, defined by the visually estimated content of fibro-glandular dense tissue was classified as BI-RADS C.
Mammography (MG) showed a micronodular glandular pattern, spread bilaterally. Cranio-caudal (CC) and medio-lateral oblique (MLO) CESM projections didn’t show focal contrast enhancement bilaterally and documented a minimal BPE (Figure 1).
Figure 1. Case 1: 59-year-old woman DM and CESM with palpable lump in the upper outer quadrant of the left breast; DM and CESM. A, C: CC and MLO DM of fibro-glandular density tissue (BI-RADS C) B, D: CC and MLO CESM projections with minimal BPE (grade 1). DM: Digital mammography; BI-RADS: breast imaging-reporting and data system; BPE: background parenchymal enhancement; CC: craniocaudal projection; MLO: mediolateral oblique projection; CESM: contrast enhanced spectral mammography.

Case No 2: Contrast-enhanced spectral mammography characterized by mild BPE. A 62-year-old woman performed a CESM because of high familiarity risk. She was claustrophobic so she refused MR. Past medical history reported transthoracic repair of Morgagni’s hernia (22). DM breast density was graded as high BI-RADS C. CESM didn’t show any pathologic findings; small scattered areas of enhancement attributed to a mild CESM BPE were identified (Figure 2).
Figure 2. Case 2: 62-year-old woman high risk screening for BC; DM and CESM. A, C: CC and MLO digital mammography of fibroglandular density tissue (BI-RADS C) B, D: CC and MLO CESM projections with mild BPE (grade 2). BC: Breast cancer; BI-RADS: breast imaging-reporting and data system; BPE: background parenchymal enhancement; CC: craniocaudal projection; DM: digital mammography; MLO: mediolateral oblique projection; CESM: contrast enhanced spectral mammography.

Case No 3: Contrast-enhanced spectral mammography characterized by moderate BPE. A 54-year-old woman performed a CESM as a diagnostic integration DM and US. Past medical history included kidney transplant in 2015, one abortion (23), and percutaneous coronary intervention (PTCA) after non-ST elevation myocardial infarction (NSTEMI) (24). Moreover, the patient reported irregular menstrual cycles and secretions from the left nipple. The patient’s breast density DM was defined as high (BI-RADS C/D). CESM showed a widespread progressive and persistent enhancement in absence of focal pathological enhancement. These imaging features were compatible with moderate CESM BPE (Figure 3).
Figure 3. Case 3: 54-year-old II level CESM as II level imaging after DM and US; DM and CESM. A, C: CC and MLO digital mammography of high-density tissue (BI-RADS C-D). B, D: CC and MLO CESM projections with moderate BPE (grade 3). BI-RADS: Breast imagingreporting and data system; BPE: background parenchymal enhancement; CC: craniocaudal projection; DM: digital mammography; MLO: mediolateral oblique projection; MLO: mediolateral oblique projection; US: ultrasound; CESM: contrast enhanced spectral mammography.

Case No 4: Contrast-enhanced spectral mammography characterized by marked BPE. A 48-year-old woman performed a CESM as a diagnostic integration DM and US. Patient’s past medical history included Hepatitis C treated using a direct-acting antiviral (DAA) drug (25). The patient’s breast density was high BI-RADS D. Because to the familiar risk, the patient was enrolled in our BC screening program with CESM.
CESM showed multiple focal areas of early and persistent enhancement, with micro and macronodular patterns, spread bilaterally across all quadrants. These imaging features were compatible with marked CESM BPE (Figure 4).
Figure 4. 48-year-old II level CESM as II level imaging after DM and US; DM and CESM. A, C: CC and MLO digital mammography of high breast density tissue (BI-RADS D). B, D: CC and MLO CESM projections with marked BPE (grade 4). BI-RADS: Breast imaging-reporting and data system; BPE: background parenchymal enhancement; CC: craniocaudal projection; DM: digital mammography; MLO: mediolateral oblique projection; US: ultrasound contrast; CESM: contrast enhanced spectral mammography.

Discussion
CESM, firstly introduced in 2003 as alternative techniques to MR, is currently gaining popularity thanks to its feasibility, compliance of patients, and shorter procedural time (12). When compared with breast MR, CESM has higher specificity and negative predictive value (NPV) (100%), but a lower sensitivity (88%) and a positive predictive value (PPV) of 76% (16).
Because to the shorter learning curve (13), many authors have proposed this imaging method as a solving tool for inconclusive findings on screening mammography, which is limited by the glandular density. Moreover, concerning cancer staging, CESM has repeatedly shown a comparable sensitivity value but a higher specificity compared to MR, which nowadays represents the gold standard (13,16,26). Despite this popularity, due to the novelty of the procedure, standardized lexicon, recommendations, and classification are missing in CESM, as for CESM BPE. Moreover, after the first wave of COVID-19 pandemic (27,28), unification of the classifications of the CESM technique is even more urgent to provide a faster approach, with a potential reduction in the time spent in hospitals by patients and an access of a greater number of patients to diagnostic procedures (29,30).
BPE, the bilateral enhancement of the normal breast parenchyma after contrast administration, was firstly described in MR. Higher grade of BPE has been related to many factors such as radiotherapy and breast density, and hormone levels (26). Other factors linked to higher grade of BPE are the phase of menstrual cycle for women in the reproductive age, premenopausal status, and hormonal therapy (31). For this reason, some authors recommend performing MR between days 7-14 to minimize the masking effect in cancer detection (32).
Recently Sogani et al. showed that CESM BPE is comparable to MR BPE and is influenced in the same way by different and already known factors; moreover they reported a moderate intra-reader and inter-reader agreement (31). Furthermore, BPE is an important imaging aspect to evaluate, considering that it has been demonstrated to be an independent predictor of breast cancer risk, proportional to its grading. CESM BPE could be useful as an additional risk factor to detect women who need close surveillance. In a recent analysis, CESM BPE was more strongly correlated to cancer risk than other known risk factors, such as mammographic breast density, MR BPE, and fibroglandular volume (32).
As mentioned before, a common CESM BPE lexicon is still lacking and some authors suggested to use BIRADS-RM score for the MR BPE, with a visual score of the enhancement volume (minimal, mild, moderate, marked) and of its symmetric or asymmetric localization (21). In the present study, BIRADS-RM score for the CESM BPE represented a handy option for radiologists with high intra- and inter-reader agreement and early experience in CESM.
We are aware that our research has some limitations. First, the retrospective and monocentric design may have influenced our results and no recommendations in clinical practice may rise from this analysis. However, the prospectively maintained database and the blind revision may have led to a reduction in this bias. In our pictorial essay, through a review of our clinical cases and a retrospective analysis, we proposed four different stages of CESM BPE from minimal to marked, using the dual-energy subtraction technique. Larger prospective trials may provide useful information on the role of BPE in CESM in terms of clinical outcome.
The state of art is unavoidable considering the emerging importance of this technique in breast cancer diagnosis and follow-up, based on the recent proof that CESM has similar sensitivity to RM and the higher specificity (16).
We consider it worthwhile that future radiologists get increasingly involved with CESM and its correlate imaging tools, as the BPE. This represents one of the most interesting and emerging approaches to evaluate in CESM exams.
Conflicts of Interest
The Authors declare no conflicts of interest regarding this study.
Authors’ Contributions
Study conception and design: Rosaria Meucci and Chiara Adriana Pistolese; Acquisition of data: Tommaso Perretta and Emanuela Beninati; Analysis of data: Federica Di Tosto and Maria Lina Serio; Interpretation of data: Gianluca Vanni, Meucci Rosaria, Perretta Tommaso; Drafting of article: Materazzo Marco, Buonomo Oreste Claudio and Rosaria Meucci; Critical revision: Vanni Gianluca and Marco Pellicciaro; Critical revision of literature: Marco Pellicciaro, Aurelia Caliandro, Rosaria Meucci and Marco Materazzo. Clinical Case data acquisition: Emanuela Beninati, Federica Di Tosto, Maria Lina Serio, and Aurelia Caliandro. All the Authors read and approved the final version of the manuscript.
Acknowledgements
The work was partially financially supported by the Italian Ministry of Health, Rome, Italy.
References
- 1.Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, Bray F. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin. 2021;71(3):209–249. doi: 10.3322/caac.21660. [DOI] [PubMed] [Google Scholar]
- 2.Associazione Italiana di Oncologia Medica: I Numeri del Cancro in Italia, 2019. Available at: https://www.aiom.it/wp-content/uploads/2019/09/2019_Numeri_Cancro-operatori-web.pdf. [Last accessed on December 18, 2021]
- 3.Vanni G, Materazzo M, Perretta T, Meucci R, Anemona L, Buonomo C, Dauri M, Granai AV, Rho M, Ingallinella S, Tacconi F, Ambrogi V, Chiaravalloti A, Schillaci O, Petrella G, Buonomo OC. Impact of awake breast cancer surgery on postoperative lymphocyte responses. In Vivo. 2019;33(6):1879–1884. doi: 10.21873/invivo.11681. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Roselli M, Guadagni F, Buonomo O, Belardi A, Ferroni P, Diodati A, Anselmi D, Cipriani C, Casciani CU, Greiner J, Schlom J. Tumor markers as targets for selective diagnostic and therapeutic procedures. Anticancer Res. 1996;16(4B):2187–2192. [PubMed] [Google Scholar]
- 5.Zielonke N, Gini A, Jansen EEL, Anttila A, Segnan N, Ponti A, Veerus P, de Koning HJ, van Ravesteyn NT, Heijnsdijk EAM, EU-TOPIA consortium Evidence for reducing cancer-specific mortality due to screening for breast cancer in Europe: A systematic review. Eur J Cancer. 2020;127:191–206. doi: 10.1016/j.ejca.2019.12.010. [DOI] [PubMed] [Google Scholar]
- 6.Buonomo O, Cabassi A, Guadagni F, Piazza A, Felici A, Piccirillo R, Atzei GP, Cipriani C, Schiaroli S, Mariotti S, Guazzaroni MN, Cossu E, Simonetti G, Pernazza E, Casciani CU, Roselli M. Radioguided-surgery of early breast lesions. Anticancer Res. 2001;21(3C):2091–2097. [PubMed] [Google Scholar]
- 7.Van Zee KJ, Manasseh DM, Bevilacqua JL, Boolbol SK, Fey JV, Tan LK, Borgen PI, Cody HS 3rd, Kattan MW. A nomogram for predicting the likelihood of additional nodal metastases in breast cancer patients with a positive sentinel node biopsy. Ann Surg Oncol. 2003;10(10):1140–1151. doi: 10.1245/aso.2003.03.015. [DOI] [PubMed] [Google Scholar]
- 8.Ielpo B, Pernaute AS, Elia S, Buonomo OC, Valladares LD, Aguirre EP, Petrella G, Garcia AT. Impact of number and site of lymph node invasion on survival of adenocarcinoma of esophagogastric junction. Interact Cardiovasc Thorac Surg. 2010;10(5):704–708. doi: 10.1510/icvts.2009.222778. [DOI] [PubMed] [Google Scholar]
- 9.Buonomo OC, Caredda E, Portarena I, Vanni G, Orlandi A, Bagni C, Petrella G, Palombi L, Orsaria P. New insights into the metastatic behavior after breast cancer surgery, according to well-established clinicopathological variables and molecular subtypes. PLoS One. 2017;12(9):e0184680. doi: 10.1371/journal.pone.0184680. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Ielpo B, Mazzetti C, Venditti D, Buonomo O, Petrella G. A case of metachronous splenic metastasis from renal cell carcinoma after 14 years. Int J Surg. 2010;8(5):353–355. doi: 10.1016/j.ijsu.2010.04.006. [DOI] [PubMed] [Google Scholar]
- 11.Niell BL, Freer PE, Weinfurtner RJ, Arleo EK, Drukteinis JS. Screening for breast cancer. Radiol Clin North Am. 2017;55(6):1145–1162. doi: 10.1016/j.rcl.2017.06.004. [DOI] [PubMed] [Google Scholar]
- 12.James JJ, Tennant SL. Contrast-enhanced spectral mammography (CESM) Clin Radiol. 2018;73(8):715–723. doi: 10.1016/j.crad.2018.05.005. [DOI] [PubMed] [Google Scholar]
- 13.Lalji UC, Houben IP, Prevos R, Gommers S, van Goethem M, Vanwetswinkel S, Pijnappel R, Steeman R, Frotscher C, Mok W, Nelemans P, Smidt ML, Beets-Tan RG, Wildberger JE, Lobbes MB. Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program: validation of results in a large multireader, multicase study. Eur Radiol. 2016;26(12):4371–4379. doi: 10.1007/s00330-016-4336-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Tennant SL, James JJ, Cornford EJ, Chen Y, Burrell HC, Hamilton LJ, Girio-Fragkoulakis C. Contrast-enhanced spectral mammography improves diagnostic accuracy in the symptomatic setting. Clin Radiol. 2016;71(11):1148–1155. doi: 10.1016/j.crad.2016.05.009. [DOI] [PubMed] [Google Scholar]
- 15.Alexander S, Dulku G, Hashoul S, Taylor DB. Practical uses of contrast-enhanced spectral mammography in daily work: A pictorial review. J Med Imaging Radiat Oncol. 2019;63(4):473–478. doi: 10.1111/1754-9485.12927. [DOI] [PubMed] [Google Scholar]
- 16.Patel BK, Lobbes MBI, Lewin J. Contrast enhanced spectral mammography: a review. Semin Ultrasound CT MR. 2018;39(1):70–79. doi: 10.1053/j.sult.2017.08.005. [DOI] [PubMed] [Google Scholar]
- 17.Buonomo OC, Morando L, Materazzo M, Vanni G, Pistilli G, Palla L, Di Pasquali C, Petrella G. Comparison of round smooth and shaped micro-textured implants in terms of quality of life and aesthetic outcomes in women undergoing breast reconstruction: a single-centre prospective study. Updates Surg. 2020;72(2):537–546. doi: 10.1007/s13304-020-00721-w. [DOI] [PubMed] [Google Scholar]
- 18.Nori J, Gill MK, Vignoli C, Bicchierai G, De Benedetto D, Di Naro F, Vanzi E, Boeri C, Miele V. Artefacts in contrast enhanced digital mammography: how can they affect diagnostic image quality and confuse clinical diagnosis. Insights Imaging. 2020;11(1):16. doi: 10.1186/s13244-019-0811-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Gail MH, Brinton LA, Byar DP, Corle DK, Green SB, Schairer C, Mulvihill JJ. Projecting individualized probabilities of developing breast cancer for white females who are being examined annually. J Natl Cancer Inst. 1989;81(24):1879–1886. doi: 10.1093/jnci/81.24.1879. [DOI] [PubMed] [Google Scholar]
- 20.American College of Radiology , BI-RADS Committee , Morris EA, Comstock CE, Lee CH, Lehman CD, Ikeda DM, Newstead GM. Reston, VA, USA, American College of Radiology. 2013. ACR BI-RADS® atlas, breast imaging reporting and data system. 5th Edition. [Google Scholar]
- 21.Rao AA, Feneis J, Lalonde C, Ojeda-Fournier H. A pictorial review of changes in the BI-RADS fifth edition. Radiographics. 2016;36(3):623–639. doi: 10.1148/rg.2016150178. [DOI] [PubMed] [Google Scholar]
- 22.Ambrogi V, Forcella D, Gatti A, Vanni G, Mineo TC. Transthoracic repair of Morgagni’s hernia: a 20-year experience from open to video-assisted approach. Surg Endosc. 2007;21(4):587–591. doi: 10.1007/s00464-006-9017-7. [DOI] [PubMed] [Google Scholar]
- 23.Framarino-dei-Malatesta M, Derme M, Manzia TM, Iaria G, De Luca L, Fazzolari L, Napoli A, Berloco P, Patel T, Orlando G, Tisone G. Impact of mTOR-I on fertility and pregnancy: state of the art and review of the literature. Expert Rev Clin Immunol. 2013;9(8):781–789. doi: 10.1586/1744666X.2013.824243. [DOI] [PubMed] [Google Scholar]
- 24.Noce A, Canale MP, Capria A, Rovella V, Tesauro M, Splendiani G, Annicchiarico-Petruzzelli M, Manzuoli M, Simonetti G, Di Daniele N. Coronary artery calcifications predict long term cardiovascular events in non diabetic Caucasian hemodialysis patients. Aging (Albany NY) 2015;7(4):269–279. doi: 10.18632/aging.100740. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Guarino M, Viganò L, Ponziani FR, Giannini EG, Lai Q, Morisco F, Special Interest Group on Hepatocellular carcinoma and new anti-HCV therapies” of the Italian Association for the Study of the Liver Recurrence of hepatocellular carcinoma after direct acting antiviral treatment for hepatitis C virus infection: Literature review and risk analysis. Dig Liver Dis. 2018;50(11):1105–1114. doi: 10.1016/j.dld.2018.08.001. [DOI] [PubMed] [Google Scholar]
- 26.Łuczyńska E, Heinze-Paluchowska S, Hendrick E, Dyczek S, Ryś J, Herman K, Blecharz P, Jakubowicz J. Comparison between breast MRI and contrast-enhanced spectral mammography. Med Sci Monit. 2015;21:1358–1367. doi: 10.12659/MSM.893018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Vanni G, Pellicciaro M, Materazzo M, Palombi L, Buonomo OC. Breast cancer diagnosis in Coronavirus-era: alert from Italy. Front Oncol. 2020;10:938. doi: 10.3389/fonc.2020.00938. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Vanni G, Materazzo M, Santori F, Pellicciaro M, Costesta M, Orsaria P, Cattadori F, Pistolese CA, Perretta T, Chiocchi M, Meucci R, Lamacchia F, Assogna M, Caspi J, Granai AV, DE Majo A, Chiaravalloti A, D’Angelillo MR, Barbarino R, Ingallinella S, Morando L, Dalli S, Portarena I, Altomare V, Tazzioli G, Buonomo OC. The effect of Coronavirus (COVID-19) on breast cancer teamwork: a multicentric survey. In Vivo. 2020;34(3 Suppl):1685–1694. doi: 10.21873/invivo.11962. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Buonomo OC, Materazzo M, Pellicciaro M, Caspi J, Piccione E, Vanni G. Tor Vergata University-Hospital in the beginning of COVID-19-era: Experience and recommendation for breast cancer patients. In Vivo. 2020;34(3 Suppl):1661–1665. doi: 10.21873/invivo.11958. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Vanni G, Pellicciaro M, Materazzo M, Bruno V, Oldani C, Pistolese CA, Buonomo C, Caspi J, Gualtieri P, Chiaravalloti A, Palombi L, Piccione E, Buonomo OC. Lockdown of breast cancer screening for COVID-19: Possible scenario. In Vivo. 2020;34(5):3047–3053. doi: 10.21873/invivo.12139. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Sogani J, Morris EA, Kaplan JB, D’Alessio D, Goldman D, Moskowitz CS, Jochelson MS. Comparison of background parenchymal enhancement at contrast-enhanced spectral mammography and breast MR imaging. Radiology. 2017;282(1):63–73. doi: 10.1148/radiol.2016160284. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.King V, Brooks JD, Bernstein JL, Reiner AS, Pike MC, Morris EA. Background parenchymal enhancement at breast MR imaging and breast cancer risk. Radiology. 2011;260(1):50–60. doi: 10.1148/radiol.11102156. [DOI] [PMC free article] [PubMed] [Google Scholar]