COVID-19 cases are putting pressure on healthcare systems all around the world. Due to the lack of available testing kits, it is impractical for screening every patient with a respiratory ailment using traditional methods (RT-PCR). In addition, the tests have a high turn-around time and low sensitivity. Detecting suspected COVID-19 infections from the chest X-ray might help isolate high-risk people before the RT-PCR test. Most healthcare systems already have X-ray equipment, and because most current X-ray systems have already been computerized, there is no need to transfer the samples. The use of a chest X-ray to prioritize the selection of patients for subsequent RT-PCR testing is the motivation of this work. Transfer learning (TL) with fine-tuning on deep convolutional neural network-based ResNet50 model has been proposed in this work to classify COVID-19 patients from the COVID-19 Radiography Database. Ten distinct pre-trained weights, trained on varieties of large-scale datasets using various approaches such as supervised learning, self-supervised learning, and others, have been utilized in this work. Our proposed iNat2021_Mini_SwAV_1k model, pre-trained on the iNat2021 Mini dataset using the SwAV algorithm, outperforms the other ResNet50 TL models. For COVID instances in the two-class (Covid and Normal) classification, our work achieved 99.17% validation accuracy, 99.95% train accuracy, 99.31% precision, 99.03% sensitivity, and 99.17% F1-score. Some domain-adapted (ImageNet_ChestXray14) and in-domain (ChexPert, ChestX-ray14) models looked promising in medical image classification by scoring significantly higher than other models.

Keywords: Deep learning, Transfer learning, ResNet50, COVID-19

1. Introduction

In December 2019, Wuhan, China, was the first person to develop a novel corona viral disease (called COVID-19). So far, millions and thousands of deaths have been confirmed worldwide [1]. A 2019 coronavirus disease (COVID-19) due to serious coronavirus acute syndrome 2 (SARS-CoV-2) has become a pandemic and widely spread around the world. The COVID-19 outbreak has affected many aspects, such as everyday life, public health, and the world economy. The World Health Organization announced on 28 June 2020 that more than 10 million confirmed COVID-19 cases have been reported in the world and over 499,000 persons have died. Furthermore, in China, approx. 6.47 (range 1.66–10) [2], in South Korea 2.6 [3], and in Iran 4.7 [4] in the basic reproductive (R0), are defined as the average number of secondary cases born by an infected individual, which indicates that there is a serious spread of COVID-19. Due to the non-availability of specific therapeutic drugs or COVID-19 vaccines [5], the main priority is to stop the spread of COVID-19 through the testing of many suspicious cases and isolation from the community of the infected. As per Chinese government’s most recent guidelines, the diagnosis of COVID-19 should be validated by a reverse transcription-polymerase chain reaction (RT-PCR). In terms of sensitivity, however, RT-PCR may not be high enough. False negatives can also occur when there is a lack of virus quantities in the sample; therefore, several times before the test is finally confirmed, it may be necessary [6], [7], [8]. As a result, rapid and precise diagnostic procedures or instruments are required to battle SARS-CoV-2 as soon as possible.

Chest CT is a routine pneumonia imagery tool that provides an advantage for COVID-19 diagnosis. Most COVID-19 patients show similar characteristics on CT images, such as opacity of the ground glass, pulmonary consolidation, and/or peripheral-lung changes [9], [10]. Whilst chest CT may be an early screening method for COVID-19, this and other kinds of infectious and inflammatory lung illness have significant imaging similarities. It is therefore not easy to distinguish between COVID-19 and other viral pneumonia. Radiologists can also take a long time to identify the characteristics. In addition, manual reading of CT images is a long and tiring task, leading to human error in turn. Thus, technology using automated analysis based on artificial intelligence (AI) can assist radiologists in the analysis of COVID-19 from CT images.

The important achievement in AI is deep learning (DL) [11]. The convolutional neural network (CNN) is one of the typical DL architectures [12]. Because of its strong characteristics [13], [14], [15], [16], [17], CNN has been widely applied in the health sector. CNN techniques can help in the accurate detection and classification of COVID-19 along with the implementation of radiological imaging [18]. Recent CNN images of COVID-19 and Non-COVID-19 have been classified using a CT-Classification approach [19], [20], [21], [22].

Our experiment utilized the transfer learning (TL) [12] method on a well-known CNN model named ResNet50 to build our COVID-19 detection model. We used 10 different pre-trained weights and all of those ResNet50 model’s weights trained on different image datasets. We utilized those pre-trained weights and applied the transfer learning approach on a different chest X-ray images dataset for classifying Covid or Normal patients. Some pre-trained models performed very well and we found some insights on the TL approach for medical images classification system especially on chest X-ray images. We applied to fine-tune on ResNet50 model for better performance. This work achieves over 99% accuracy for classifying Covid and Normal patients on chest X-ray images. The contribution of our work is as follows:

  • We propose a fine-tuned ResNet50 model applying transfer learning technique with ten different pre-trained weights for classifying COVID-19 from chest X-ray images.

  • We have modified ResNet50 model by adding extra two fully connected layers than the default ResNet50 model for applying fine tuning in our task.

  • We conduct experiments on the COVID-19 Radiography dataset utilizing pre-trained weights trained on varieties of large-scale datasets and comparison with existing models to show the effectiveness of the proposed model.

The remainder of the paper is structured as follows. In Section 2, we presented a quick literature review. The proposed methodology is stated in Section 3, which also explains experimental Setup, Model Training, and Evaluation. The result analysis and discussions are presented in Section 4. Finally, Section 5 concludes the paper.

2. Literature review

Recently, many researchers did the research in medical sector especially medical image processing techniques. They used machine learning (ML) techniques and DL techniques and so on. ML tools are widely accepted as a prominent tool to improve the prediction and diagnosis of many diseases [23], [24]. However, to obtain better ML models, efficient extraction techniques are needed. In medical imaging systems, DL models are therefore widely accepted as they can automatically extract features or use some pre-trained networks like ResNet [25]. In [26], the VGG16 model is proposed for classifying COVID-19 pneumonia and non-COVID-19 pneumonia on the chest X-ray images. In [27], the authors used the pulmonary nodules in CT images through a multifaceted convolution network. The deep networks [28] are used to segment abdominal CT images by deep opponents. The authors used 3-D CNN in Chest CT for the detection of chest nodules [29]. In order to classify the coronary artery plaque and stenosis in the Coronary CT, authors applied a classification procedure using recurrent CNN [30]. A new CNN model was proposed for chest X-ray image classification [31]. As pre-trained CNN models are known to present practical problems, the authors developed a shallow CNN architecture. The authors have used a 12-class chest X-ray image dataset with a measured accuracy of 86%. Nardelli et al. [32] used CNN 3-D to categorize chest CT pulmonary artery-vein. To classify CT-images of interstitial lung disease a deep CNN was applied [33]. A TL approach was applied on VGG16 and ResNet50 models for classifying COVID-19, pneumonia infection and, no infection [34]. The study showed 97.67% accuracy using the VGG16 TL model on the Covid-19 radiography dataset. A deep CNN CoroNet [35] was proposed and showed 89% accuracy on chest X-ray images for 4-class classification including COVID-19 class. DarkCovidNet [18], a deep model was proposed on chest X-ray images. A deep CNN DeTraC [36] model was proposed to classify COVID-19 chest X-ray images and showed 93.1% accuracy.

Unlike the above studies, in this work, we propose a fine-tuned ResNet50 model applying transfer learning technique for effectively classifying COVID-19 from chest X-ray images, where we have modified ResNet50 model by adding extra two fully connected layers than the default ResNet50 model.

3. Proposed methodology

In this work, we proposed a transfer learning method to classify Covid vs Normal patients from chest X-ray images by utilizing various pre-trained ResNet50 TL models weights. A diagram of the proposed method is depicted in Fig. 1.

Fig. 1.

Fig. 1

A block diagram of the proposed methodology.

Chest X-ray images dataset is used and we split the dataset randomly into train and test (validation) sets. Data transformation is applied without data augmentation. Ten different pre-trained ResNet50 model weights are used which are trained on different types of natural and medical images dataset. ResNet50 [37] model has loaded with these pre-trained weights with fine-tuning the model for better performance. Then training and evaluation are applied on these ResNet50 fine-tuned TL models. After training and evaluation are performed, we compare these TL models and propose the best ResNet50 fine-tuned TL model. Finally, chest X-ray images are input into the proposed model and, it provides the predicted output as either Covid or Normal using binary classification.

3.1. Dataset description

The researchers used the COVID-19 Radiography Database to carry out experiments [38], [39]. A team of researchers and collaborators with medical doctors created this database from multiple international sources at different timescales [14], [40], [41], [42]. There are four categories (Covid, Lung Opacity, Viral Pneumonia, and Normal) of chest X-ray (CXR) images in this database. All images are of 299 × 299 pixel resolution and in Portable Network Graphics (PNG) file format. The images are in gray-scale having three channels that contain repeated RGB values.

Table 1 presents the number of images of different classes in the COVID-19 Radiography Database. The numbers of images are not balanced for all four concept classes. Two classes out of four classes comprising Covid and Normal are used in our work. To create a balanced dataset, we select a subset of the Normal class.

Table 1.

COVID-19 radiography database.

Covid Lung opacity Viral pneumonia Normal Total
3616 6012 1345 10 192 21 165

Table 2 presents the number of images used for the train and test (validation) set of two different classes. We divided the datasets into two sets train set and test or validation set by selecting images randomly with proportions 80% and 20%, respectively. The train set is used for model training and the test set is used for validating the model. Some Covid and Normal patients CXR images of this dataset are shown in Fig. 2, Fig. 3.

Table 2.

Dataset splitting of Covid and Normal images into train and test set.

Set Covid Normal Total
Train 2892 2917 5809
Test 723 730 1453
Total 3615 3647 7262

Fig. 2.

Fig. 2

Example of Covid CXR images of COVID-19 Radiography Database.

Fig. 3.

Fig. 3

Example of Normal CXR images of COVID-19 Radiography Database.

Data preprocessing, augmentation, and transformation are important parts of some computer vision models. In our experiment, no data augmentation techniques are applied. We only applied a transformation to resize the images to 224 × 224 pixel resolution from 299 × 299 pixel resolution for the ResNet50 model.

3.2. ResNet50 TL model and pre-trained weights

One of the well-known models which perform very well in different computer vision problems is ResNet [37]. Some of the others are VGG [43], DenseNet [44], Inception v3 [45], AlexNet [46], MobileNet [47], GoogLeNet [48] etc. These models are trained on a vast amount of datasets with various categories of images. Transfer learning techniques can utilize these pre-trained models weights on different computer vision problems with limited resources (dataset and computing resources). In this work, we utilized 10 different pre-trained weights of the ResNet50 model to carry out transfer learning on the limited medical images dataset (COVID-19 Radiography Database). In the following parts, we have described the architecture of the ResNet50 TL model and 10 different pre-trained weights. ResNet50 model is a CNN model consisting of 50 layers. The architecture of the ResNet50 model including fine-tuning configuration for ResNet50 TL is depicted in Fig. 4.

Fig. 4.

Fig. 4

Fine tuned ResNet50 TL architecture.

Also the architecture for proposed fine-tuned ResNet50 TL presented in Table 3.

Table 3.

Architecture for proposed fine-tuned ResNet50 TL. Building blocks are shown in brackets, with the numbers of blocks stacked. Downsampling is performed by conv3_1, conv4_1, and conv5_1 with a stride of 2.

Layer name Output size Layer
conv1 112 × 112 7 × 7, 64, stride 2

conv2_x 56 × 56 3 × 3 max pool, stride 2
[1 × 1, 64
3 × 3, 64
1 × 1, 256] ×3

conv3_x 28 × 28 [1 × 1, 128
3 × 3, 128
1 × 1, 512] ×4

conv4_x 14×14 [1×1, 256
3 × 3, 256
1 × 1, 1024] ×6

conv5_x 7 × 7 [1 × 1, 512
3 × 3, 512
1 × 1, 2048] ×3

fc1 1 × 1 Average pool
in_features = 2048, out_features = 2048

fc2 1 × 1 Dropout 0.5
in_features = 2048, out_features = 2048

fc3 1 × 1 relu, dropout 0.5
in_features = 2048, out_features=2

There are a series of convolutional (conv) layers in ResNet50 architecture. First conv layer is made of 7 × 7 kernel size and 64 different kernels with a stride size of 2. Then 3 × 3 max pooling with the stride of size 2 is applied. In the next convolution, there are three conv layers (1 × 1, 64 kernels), (3 × 3, 64 kernels) and (1 × 1, 256 kernels) respectively and these three layers are repeated in total 3 times. In the same process, three conv layers (1 × 1, 128 kernels), (3 × 3, 128 kernels) and (1 × 1, 512 kernels) respectively are repeated four times; three conv layers (1 × 1, 256 kernels), (3 × 3, 256 kernels) and (1 × 1, 1024 kernels) respectively are repeated six times and another three conv layers (1 × 1, 512 kernels), (3 × 3, 512 kernels) and (1 × 1, 2048 kernels) respectively are repeated 3 times. Then average polling (avg pool) is applied. Most of the hidden layers use Batch Normalization, and ReLU followed by a conv layer. The final layer of the original ResNet50 model is a fully connected (fc) layer with 1000 out-features (for 1000 class). We fine-tune the ResNet50 model by replacing this fc layer with a set of fc layers. The first fc layer has 2048 out-features, then dropout with a probability of 0.5 is applied. The second fc layer is the same as the first fc layer. After the second fc layer, ReLU and dropout with probability 0.5 are applied. The final fc layer consists of 2048 in-features and only 2 out-features for two-class classification (Covid vs Normal).

In this work, we experimented with transfer learning of 10 different pre-trained weights of the ResNet50 model. These pre-trained weights are generated from different datasets. These datasets have many variations. As we are experimenting with medical images datasets. Medical images (chest X-rays) are very different than other real-world images. Researchers are experimenting on various aspects of transfer learning for medical images like chest X-rays and CT scan images. Supervised transfer learning model trained on ImageNet dataset has been frequently used in medical image analysis. The recent study [49] proposed that pre-trained models on fine-grained data are suitable for medical analysis and continual pre-training can reduce the domain gap between natural and medical images. The iNat and NeWT are two large-scale fine-grained natural image data collections. Researchers explored different questions and carried out various analyses on iNat2021, NeWT, and ImageNet datasets as well as showed the strengths and weaknesses of various methods for transferability of supervised and self-supervised learning [50]. A brief description of pre-trained weights used in our experiments are listed below:

3.2.1. ChestX-ray14

This pre-trained weight is an in-domain ResNet50 model trained on the ChestX-ray14 dataset [51] consists of 112K frontal-view chest X-ray images of 30K unique patients. The detailed information on this pre-trained weight can be found in Taher et al. [49].

3.2.2. ChexPert

This pre-trained weight is an in-domain ResNet50 model trained on a large-scale publicly available ChexPert dataset [52] consisting of 224K chest X-ray images of 65K patients. The detail about this pre-trained weight can be found in Taher et al. [49].

3.2.3. ImageNet

This pre-trained weight is the ResNet50 model trained on a well-known ImageNet dataset [53]. These pre-trained weights are loaded from the PyTorch framework’s pre-trained models collection (torch.utils.model_zoo).

3.2.4. ImageNet_ChestXray14

A domain-adapted pre-trained ResNet50 model’s weight. This model was trained on two different datasets. Firstly, the model was initialized with pre-trained ImageNet weight and then again trained on the ChestX-ray14 dataset [49].

3.2.5. ImageNet_ChexPert

This is also a domain-adapted pre-trained ResNet50 model’s weight trained on two different datasets. The model was initialized with pre-trained ImageNet weight and then again trained on the ChexPert dataset [49].

3.2.6. iNat2021_Supervised

The iNat2021 [50] is a large-scale natural world dataset consisting of 2.7M images of 10K different species. This pre-trained supervised ResNet50 model’s weight was collected. This pre-trained weight was downloaded manually from the given source on that paper and the wight file name was inat2021_supervised_large.pth.tar. The model was initialized with pre-trained ImageNet weight and then trained on the iNat2021 dataset.

3.2.7. iNat2021_Supervised_From_Scratch

This pre-trained supervised ResNet50 model’s weight was also collected from the same source [50] as iNat2021_Supervised. But this model only trained on the iNat2021 dataset instead of initializing with pre-trainedImageNet weight.inat2021_supervised_large_from_scratch.pth.tar was the name of the pre-trained weight file.

3.2.8. iNat2021_Mini_SwAV_1k

The iNat2021 Mini [50] is a smaller (500K images) version of the iNat2021 dataset that contains 50 training images per species. This pre-trained ResNet50 model utilized a self-supervised SwAV algorithm [54] while training on the iNat2021 Mini dataset. The pre-trained weight is collected from the same source paper as iNat2021_Supervised and iNat2021_Supervised_From_Scratch. The file name of the pre-trained weight was inat2021_swav_mini_1000_ep.pth.

3.2.9. MoCo_v1

One of the self-supervised learning (SSL) methods is MoCo (Momentum Contrast) v1. This is a contrastive learning method. The pre-trained ResNet50 model’s weight which is trained on the ImageNet dataset utilizing MoCo v1 was collected [55]. This weight was trained over 200 epochs.

3.2.10. MoCo_v2

The SSL method MoCo_v2 is the improved version of MoCo_v1. The pre-trained ResNet50 TL model’s weight which is trained on the ImageNet dataset utilizing MoCo_v2 was collected from these [55], [56] research paper. This weight was trained over 800 epochs.

All these pre-trained ResNet50 model weights are used to initialize our ResNet50 TL models. After initializing these pre-trained weights, we trained our models on the COVID-19 Radiography dataset.

3.3. Experimental setup, training, and evaluation

Model training and evaluation tasks are performed on Google Colaboratory with GPU runtime. We make use of PyTorch, an open-source machine learning package created largely by Facebook’s AI Research department. PyTorch data loader is used to load the data with a batch size of 32. We use the same configuration and same dataset for all models. Datasets are downloaded from Kaggle datasets (COVID-19 Radiography Database) using Kaggle API. Google drive is used for storing the dataset’s file names as well as trained models checkpoints.

The repeated training technique is taken for several epochs. We trained all models 50 epochs. The training dataset is used for model training, and the test dataset is used for model evaluation. In each epoch, we calculate the cross-entropy loss on the train and test set. We use Adam [57] optimizer with a learning rate of 0.001, betas of (0.9, 0.999), eps of 1e08, weight decay of 0. Table 4 presents hyperparameters of our experimental setup.

Table 4.

Hyperparameters of ResNet50 TL model.

Parameters Parameters value
Batch size 32
Optimizer Adam
Learning rate 0.001
Betas (0.9, 0.999)
Eps 1e−08
Weight decay 0
Criterion Cross Eentropy Loss

The train and validation loss depicted in Fig. 5 gives us an overview of how the model trained over a series of epochs. We see the train and validation loss of most of the models are very close to and overlap each other. But iNat2021_Mini_SwAV_1k model shows a different picture. The validation loss is increased over epochs while the training loss decreased slightly. Although the initial loss is very little compared to other models. On the other hand, MoCo_v2 and ImageNet do not show improvement over a higher number of epochs. Another thing we noticed is that decreasing rate of loss was very high in the initial stages (fewer epochs) and this rate becomes almost constant on higher epochs. This could be because of the transfer learning technique with pre-trained weights.

Fig. 5.

Fig. 5

Train and validation loss of different ResNet50 TL models.

Train and validation accuracy of different models are depicted in Fig. 6. It shows that most of the models reaches their highest accuracy very quickly because of transfer learning with pre-trained weights. No overfitting is shown up in any models. MoCo_v1 shows a fluctuation of validation accuracy at the 29th epoch where it sharply decreases the validation accuracy. We can also see a similar pattern in Chest_Xray14 but the accuracy difference is smaller than MoCo_v1. On the other hand, we see an interesting pattern on ImageNet and MoCo_v2 models that validation accuracy is higher than train accuracy but does not overlap like iNat2021_Supervised and iNat2021_Supervised_From_Scratch. The opposite picture we can see in ChexPert, ImageNet_ChestXray14, and iNat2021_Mini_SwAV_1k models where train accuracy is higher than validation accuracy but the difference of those accuracies are little.

Fig. 6.

Fig. 6

Train and validation accuracy of different ResNet50 TL models.

Fig. 7, shows a comparative summary of train and validation losses as well as train and validation accuracies of all models. If we compare train loss of different models, it shows that iNat2021_Mini_SwAV_1k comes first in terms of lowest loss and MoCo_v2 and ImageNet come last over 50 epochs of training. In terms of validation loss, we can see iNat2021_Mini_SwAV_1k achieves the lowest loss in the fewer number of epochs but the loss increases gradually in higher epochs. ChexPert and ImageNet_ChestXray14 compete with each other for the lowest loss and MoCo_v2 and ImageNet competes for the highest loss. In terms of training and validation accuracy, iNat2021_Mini_SwAV_1k comes first with the highest accuracy, and MoCo_v2 and, ImageNet come last with lower accuracies. Hence, it shows that iNat2021_Mini_SwAV_1k, ImageNet_ChestXray14, and ChexPert models perform very well with higher training and validation accuracy.

Fig. 7.

Fig. 7

Train and validation losses and accuracies of all ResNet50 TL models.

4. Result analysis and discussion

Confusion Matrix, Precision, Recall, F1 Score, and Accuracy are the standard evaluation method for the classification model. As the name suggests, the Confusion Matrix gives us a matrix as output and describes the complete performance of the model [58]. It has four terminologies including True Positive (TP), False Positive (FP), False Negative (FN), and True Negative (TN).

Precision is the number of correctly identified cases among all the identified cases.

Precision,P=TP/(TP+FP) (1)

Recall is the number of correctly identified cases from all the positive representations.

Recall,R=TP/(TP+FN) (2)

F1 Score is the harmonic average of precision and recall.

F1Score,F1=2×(P×R)/(P+R) (3)

Accuracy, on the other hand, can be define as the ratio of corrected predictions to the total input samples.

Accuracy=(Numberofcorrectpredictions)/(Totalnumberofpredictionsmade) (4)

The confusion matrix of the evaluation of all models is shown in Fig. 8. It shows that iNat2021_Mini_SwAV_1k correctly identified Covid and Normal (without COVID-19) with 99% samples. ChexPert classified Covid with 99% and Normal with 98% samples correctly. ImageNet_ChestXray14 classified Covid with 99% and Normal with 97% samples correctly. And ChestX-ray14 classified Covid with 98% and Normal with 97% samples correctly. On the other hand, MoCo_v2 and ImageNet scores are very low compared to other models. We can conclude that the iNat2021_Mini_SwAV_1k achieves the highest score among all other models.

Fig. 8.

Fig. 8

Confusion Matrix of ResNet50 TL models.

Various standard evaluation scores are shown in Table 5, where column Support represents the number of samples is used during evaluation. The evaluation has been done on the test dataset which contains 1453 chest X-ray images where 723 Covid class and 730 Normal class. The precision, recall, and f1-score are calculated both for the Covid class and Normal class.

Table 5.

Various scores calculated in test dataset for different ResNet50 TL model where Pre = Precision, Re = Recall, F1 = F1-score, Sup = Support, Acc = Accuracy, INCXR14 =ImageNet_ChestXray14, INCxP =ImageNet_ChexPert, iNSup =iNat2021_Supervised, iNSupFS =iNat2021_Supervised_From_Scratch, iNMSwAV =iNat2021_Mini_SwAV_1k.

Model Class Pre Re F1 Sup Acc
ChestX-ray14 Covid 0.9791 0.9737 0.9764 723 0.9766
Normal 0.9741 0.9795 0.9768 730
ChexPert Covid 0.9861 0.9834 0.9848 723 0.9849
Normal 0.9836 0.9863 0.9850 730
ImageNet Covid 0.8394 0.7953 0.8168 723 0.8224
Normal 0.8073 0.8493 0.8278 730
INCXR14 Covid 0.9902 0.9737 0.9819 723 0.9821
Normal 0.9744 0.9904 0.9823 730
INCxP Covid 0.9650 0.9544 0.9597 723 0.9601
Normal 0.9553 0.9658 0.9605 730
iNSup Covid 0.9635 0.9488 0.9561 723 0.9566
Normal 0.9501 0.9644 0.9572 730
iNSupFS Covid 0.9696 0.9710 0.9703 723 0.9704
Normal 0.9712 0.9699 0.9705 730
iNMSwAV Covid 0.9931 0.9903 0.9917 723 0.9917
Normal 0.9904 0.9932 0.9918 730
MoCo_v1 Covid 0.9411 0.9281 0.9345 723 0.9353
Normal 0.9297 0.9425 0.9361 730
MoCo_v2 Covid 0.7974 0.8382 0.8173 723 0.8135
Normal 0.8312 0.7891 0.8096 730

Table 5 shows that the iNat2021_Mini_SwAV_1k model achieves the highest precision, recall, f1-score, and accuracy score among all models. Also, the scores are very promising. The precision, recall and f1-score are 99.31%, 99.03% and 99.17% respectively for Covid class and 99.04%, 99.32% and 99.18% respectively for Normal class including 99.17% validation accuracy. That means all the evaluation scores are above 99%. On the other hand, ImageNet and MoCo_v2 have gotten minimum scores amongst other models. Although ImageNet_ChestXray14, ChexPert and ChestX-ray14 have achieved above 97% f1-score, the ImageNet_ChestXray14 identified covid class over complete samples 99% correctly.

Table 6 shows the maximum, minimum, and average accuracy as a summary of all TL models during training and validation. From the table, we can summarize that the iNat2021_Mini_SwAV_1k model has reached the highest position by achieving maximum train (99.95%) and validation (99.52%) accuracy among other models.

Table 6.

Accuracy summary of different ResNet50 TL models during 50 epochs of training where Acmx = Maximum Accuracy, Acmn = Minimum Accuracy, Avacy = Average Accuracy, E = epoch, INCXR14 =ImageNet_ChestXray14, INCxP =ImageNet_ChexPert, iNSup =iNat2021_Supervised, iNSupFS =iNat2021_Supervised_From_Scratch, iNMSwAV =iNat2021_Mini_SwAV_1k.

Model Set Acmx Acmx
at E
Acmn Acmn
at E
Avacy
of 50E
ChestX-ray14 Train 0.9764 47 0.8988 1 0.9688
Test 0.9780 36 0.9456 3 0.9696
ChexPert Train 0.9886 30 0.9107 1 0.9810
Test 0.9862 41 0.5038 1 0.9701
ImageNet Train 0.8024 44 0.6729 1 0.7925
Test 0.8259 31 0.7688 1 0.8123
INCXR14 Train 0.9904 34 0.9206 1 0.9823
Test 0.9828 46 0.5561 2 0.9644
INCxP Train 0.9583 18 0.8879 1 0.9519
Test 0.9621 43 0.6965 1 0.9514
iNSup Train 0.9494 42 0.8666 1 0.9419
Test 0.9566 24 0.7770 1 0.9467
iNSupFS Train 0.9594 31 0.8816 1 0.9506
Test 0.9711 42 0.9284 6 0.9611
iNMSwAV Train 0.9995 39 0.9363 1 0.9951
Test 0.9952 23 0.9140 1 0.9892
MoCo_v1 Train 0.9379 44 0.8179 1 0.9289
Test 0.9353 45 0.8665 29 0.9256
MoCo_v2 Train 0.8027 42 0.7447 1 0.7917
Test 0.8135 47 0.5045 1 0.7961

4.1. Comparison result

Several numbers of research have been done for the identification and classification of COVID-19 in recent years. Researchers are trying to find out a better way to solve this problem. We examined and compared our suggested model with an existing similar work in this part shown in Table 7.

Table 7.

Comparison of the proposed model using similar existing studies.

SN Reference Method Accuracy (%)
01 [59] COVIDX-Net 90
02 [60] MADE-based CNN 94.65 ±2.1
03 [61] VGG16 80
04 [62] Deep CNN 93
05 [63] UNet3D Deep Network 90.80
06 [21] ResNet + Location Attention 86.70
07 [36] DeTraC Deep CNN 93.1
08 [34] VGG16 97.67
09 Proposed iNat2021_Mini_SwAV_1k (Fine-tuned ResNet50) 99.17

The above-related studies proposed different approaches to carry out the solution for classifying COVID-19 from medical images. Our work has achieved 99.17% validation accuracy on the COVID-19 Radiography dataset. Ten different pre-trained ResNet50 are used in this work. Among them, the iNat2021_Mini_SwAV_1k model shows excellent performance.

5. Conclusion and future work

In this paper, we have presented a fine-tuned ResNet50 model applying transfer learning technique for effectively classifying COVID-19 from chest X-ray images. For this, we have modified the ResNet50 model by adding extra two fully connected layers than the default ResNet50 model. We have utilized ten different pre-trained weights, trained on varieties of large-scale datasets applying various methods such as supervised learning, self-supervised learning, etc. Among these ResNet50 TL models, the iNat2021_Mini_SwAV_1k model performs excellent that was pre-trained on the iNat2021 Mini dataset with the SwAV algorithm. Our work achieved 99.17% validation accuracy, 99.95% train accuracy, the precision of 99.31%, recall of 99.03%, and an F1-score of 99.17% for covid cases in the two-class classification (Covid and Normal). Some domain-adapted (ImageNet_ChestXray14) and in-domain (ChexPert, ChestX-ray14) models showed promising importance in medical image classification by achieving relatively better scores than models only trained on ImageNet dataset. As future work, we can conduct further studies to present a qualitative representation of transfer knowledge to our model and detect the region of interest of COVID-19 in medical images.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

  • 1.Mahase E. 2020. Coronavirus: covid-19 has killed more people than SARS and MERS combined, despite lower case fatality rate. [DOI] [PubMed] [Google Scholar]
  • 2.Tang B., Wang X., Li Q., Bragazzi N.L., Tang S., Xiao Y., Wu J. Estimation of the transmission risk of the 2019-nCoV and its implication for public health interventions. J Clin Med. 2020;9(2):462. doi: 10.3390/jcm9020462. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Tang B., Xia F., Bragazzi N.L., McCarthy Z., Wang X., He S., Sun X., Tang S., Xiao Y., Wu J. Lessons drawn from China and South Korea for managing COVID-19 epidemic: insights from a comparative modeling study. ISA Trans. 2021 doi: 10.1016/j.isatra.2021.12.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Ahmadi A., Fadaei Y., Shirani M., Rahmani F. Modeling and forecasting trend of COVID-19 epidemic in Iran until may 13, 2020. Med J Islamic Repub Iran. 2020;34:27. doi: 10.34171/mjiri.34.27. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Gao Q., Bao L., Mao H., Wang L., Xu K., Yang M., Li Y., Zhu L., Wang N., Lv Z., et al. Development of an inactivated vaccine candidate for SARS-CoV-2. Science. 2020;369(6499):77–81. doi: 10.1126/science.abc1932. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Corman V.M., Landt O., Kaiser M., Molenkamp R., Meijer A., Chu D.K., Bleicker T., Brünink S., Schneider J., Schmidt M.L., et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Eurosurveillance. 2020;25(3) doi: 10.2807/1560-7917.ES.2020.25.3.2000045. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Chu D.K., Pan Y., Cheng S.M., Hui K.P., Krishnan P., Liu Y., Ng D.Y., Wan C.K., Yang P., Wang Q., et al. Molecular diagnosis of a novel coronavirus (2019-nCoV) causing an outbreak of pneumonia. Clin Chem. 2020;66(4):549–555. doi: 10.1093/clinchem/hvaa029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Zhang N., Wang L., Deng X., Liang R., Su M., He C., Hu L., Su Y., Ren J., Yu F., et al. Recent advances in the detection of respiratory virus infection in humans. J Med Virol. 2020;92(4):408–417. doi: 10.1002/jmv.25674. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Ai T., Yang Z., Hou H., Zhan C., Chen C., Lv W., Tao Q., Sun Z., Xia L. Correlation of chest CT and RT-PCR testing for coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases. Radiology. 2020;296(2):E32–E40. doi: 10.1148/radiol.2020200642. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Wang S., Kang B., Ma J., Zeng X., Xiao M., Guo J., Cai M., Yang J., Li Y., Meng X., et al. A deep learning algorithm using CT images to screen for corona virus disease (COVID-19) Eur Radiol. 2021:1–9. doi: 10.1007/s00330-021-07715-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Sarker I.H. AI-based modeling: Techniques, applications and research issues towards automation, intelligent and smart systems. SN Comput Sci. 2022:1–20. doi: 10.1007/s42979-022-01043-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Sarker I.H. Deep learning: a comprehensive overview on techniques, taxonomy, applications and research directions. SN Comput Sci. 2021;2(6):1–20. doi: 10.1007/s42979-021-00815-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Choe J., Lee S.M., Do K.-H., Lee G., Lee J.-G., Lee S.M., Seo J.B. Deep learning–based image conversion of CT reconstruction kernels improves radiomics reproducibility for pulmonary nodules or masses. Radiology. 2019;292(2):365–373. doi: 10.1148/radiol.2019181960. [DOI] [PubMed] [Google Scholar]
  • 14.Kermany D.S., Goldbaum M., Cai W., Valentim C.C., Liang H., Baxter S.L., McKeown A., Yang G., Wu X., Yan F., et al. Identifying medical diagnoses and treatable diseases by image-based deep learning. Cell. 2018;172(5):1122–1131. doi: 10.1016/j.cell.2018.02.010. [DOI] [PubMed] [Google Scholar]
  • 15.Negassi M., Suarez-Ibarrola R., Hein S., Miernik A., Reiterer A. Application of artificial neural networks for automated analysis of cystoscopic images: a review of the current status and future prospects. World J Urol. 2020:1–10. doi: 10.1007/s00345-019-03059-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Wang P., Xiao X., Brown J.R.G., Berzin T.M., Tu M., Xiong F., Hu X., Liu P., Song Y., Zhang D., et al. Development and validation of a deep-learning algorithm for the detection of polyps during colonoscopy. Nat Biomed Eng. 2018;2(10):741–748. doi: 10.1038/s41551-018-0301-3. [DOI] [PubMed] [Google Scholar]
  • 17.Yan Q., Wang B., Gong D., Luo C., Zhao W., Shen J., Shi Q., Jin S., Zhang L., You Z. 2020. COVID-19 chest CT image segmentation–a deep convolutional neural network solution. arXiv preprint arXiv:2004.10987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Ozturk T., Talo M., Yildirim E.A., Baloglu U.B., Yildirim O., Acharya U.R. Automated detection of COVID-19 cases using deep neural networks with X-ray images. Comput Biol Med. 2020;121 doi: 10.1016/j.compbiomed.2020.103792. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Ardakani A.A., Kanafi A.R., Acharya U.R., Khadem N., Mohammadi A. Application of deep learning technique to manage COVID-19 in routine clinical practice using CT images: Results of 10 convolutional neural networks. Comput Biol Med. 2020;121 doi: 10.1016/j.compbiomed.2020.103795. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Li L., Qin L., Xu Z., Yin Y., Wang X., Kong B., Bai J., Lu Y., Fang Z., Song Q., et al. Artificial intelligence distinguishes COVID-19 from community acquired pneumonia on chest CT. Radiology. 2020 doi: 10.1148/radiol.2020200905. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Xu X., Jiang X., Ma C., Du P., Li X., Lv S., Yu L., Ni Q., Chen Y., Su J., et al. A deep learning system to screen novel coronavirus disease 2019 pneumonia. Engineering. 2020;6(10):1122–1129. doi: 10.1016/j.eng.2020.04.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Chen J., Wu L., Zhang J., Zhang L., Gong D., Zhao Y., Chen Q., Huang S., Yang M., Yang X., et al. Deep learning-based model for detecting 2019 novel coronavirus pneumonia on high-resolution computed tomography. Sci Rep. 2020;10(1):1–11. doi: 10.1038/s41598-020-76282-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Shukla P.K., Shukla P.K., Sharma P., Rawat P., Samar J., Moriwal R., Kaur M. Efficient prediction of drug–drug interaction using deep learning models. IET Syst Biol. 2020;14(4):211–216. doi: 10.1049/iet-syb.2019.0116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Kaur M., Gianey H.K., Singh D., Sabharwal M. Multi-objective differential evolution based random forest for e-health applications. Modern Phys Lett B. 2019;33(05) [Google Scholar]
  • 25.Yu Y., Lin H., Meng J., Wei X., Guo H., Zhao Z. Deep transfer learning for modality classification of medical images. Information. 2017;8(3):91. [Google Scholar]
  • 26.Nishio M., Noguchi S., Matsuo H., Murakami T. Automatic classification between COVID-19 pneumonia, non-COVID-19 pneumonia, and the healthy on chest X-ray image: combination of data augmentation methods. Sci Rep. 2020;10(1):1–6. doi: 10.1038/s41598-020-74539-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Setio A.A.A., Ciompi F., Litjens G., Gerke P., Jacobs C., Van Riel S.J., Wille M.M.W., Naqibullah M., Sánchez C.I., Van Ginneken B. Pulmonary nodule detection in CT images: false positive reduction using multi-view convolutional networks. IEEE Trans Med Imaging. 2016;35(5):1160–1169. doi: 10.1109/TMI.2016.2536809. [DOI] [PubMed] [Google Scholar]
  • 28.Xia K., Yin H., Qian P., Jiang Y., Wang S. Liver semantic segmentation algorithm based on improved deep adversarial networks in combination of weighted loss function on abdominal CT images. IEEE Access. 2019;7:96349–96358. [Google Scholar]
  • 29.Pezeshk A., Hamidian S., Petrick N., Sahiner B. 3-D convolutional neural networks for automatic detection of pulmonary nodules in chest CT. IEEE J Biomed Health Inf. 2018;23(5):2080–2090. doi: 10.1109/JBHI.2018.2879449. [DOI] [PubMed] [Google Scholar]
  • 30.Zreik M., Van Hamersvelt R.W., Wolterink J.M., Leiner T., Viergever M.A., Išgum I. A recurrent CNN for automatic detection and classification of coronary artery plaque and stenosis in coronary CT angiography. IEEE Trans Med Imaging. 2018;38(7):1588–1598. doi: 10.1109/TMI.2018.2883807. [DOI] [PubMed] [Google Scholar]
  • 31.Kesim E., Dokur Z., Olmez T. 2019 scientific meeting on electrical-electronics & biomedical engineering and computer science (EBBT) IEEE; 2019. X-ray chest image classification by a small-sized convolutional neural network; pp. 1–5. [Google Scholar]
  • 32.Nardelli P., Jimenez-Carretero D., Bermejo-Pelaez D., Washko G.R., Rahaghi F.N., Ledesma-Carbayo M.J., Estépar R.S.J. Pulmonary artery–vein classification in CT images using deep learning. IEEE Trans Med Imaging. 2018;37(11):2428–2440. doi: 10.1109/TMI.2018.2833385. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Shin H.-C., Roth H.R., Gao M., Lu L., Xu Z., Nogues I., Yao J., Mollura D., Summers R.M. Deep convolutional neural networks for computer-aided detection: CNN architectures, dataset characteristics and transfer learning. IEEE Trans Med Imaging. 2016;35(5):1285–1298. doi: 10.1109/TMI.2016.2528162. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Das A.K., Kalam S., Kumar C., Sinha D. TLCoV-An automated Covid-19 screening model using transfer learning from chest X-ray images. Chaos Solitons Fractals. 2021;144 doi: 10.1016/j.chaos.2021.110713. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Khan A.I., Shah J.L., Bhat M.M. CoroNet: A deep neural network for detection and diagnosis of COVID-19 from chest x-ray images. Comput Methods Programs Biomed. 2020;196 doi: 10.1016/j.cmpb.2020.105581. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Abbas A., Abdelsamea M.M., Gaber M.M. Classification of COVID-19 in chest X-ray images using DeTraC deep convolutional neural network. Appl Intell. 2021;51(2):854–864. doi: 10.1007/s10489-020-01829-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.He K, Zhang X, Ren S, Sun J. Deep residual learning for image recognition. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2016, p. 770–8.
  • 38.Chowdhury M.E., Rahman T., Khandakar A., Mazhar R., Kadir M.A., Mahbub Z.B., Islam K.R., Khan M.S., Iqbal A., Al Emadi N., et al. Can AI help in screening viral and COVID-19 pneumonia? IEEE Access. 2020;8:132665–132676. [Google Scholar]
  • 39.Rahman T., Khandakar A., Qiblawey Y., Tahir A., Kiranyaz S., Kashem S.B.A., Islam M.T., Al Maadeed S., Zughaier S.M., Khan M.S., et al. Exploring the effect of image enhancement techniques on COVID-19 detection using chest X-ray images. Comput Biol Med. 2021;132 doi: 10.1016/j.compbiomed.2021.104319. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Vayá M.d.l.I., Saborit J.M., Montell J.A., Pertusa A., Bustos A., Cazorla M., Galant J., Barber X., Orozco-Beltrán D., García-García F., et al. 2020. Bimcv covid-19+: a large annotated dataset of RX and CT images from covid-19 patients. arXiv preprint arXiv:2006.01174. [Google Scholar]
  • 41.Cohen J.P., Morrison P., Dao L., Roth K., Duong T.Q., Ghassemi M. 2020. Covid-19 image data collection: Prospective predictions are the future. arXiv preprint arXiv:2006.11988. [Google Scholar]
  • 42.Haghanifar A., Majdabadi M.M., Choi Y., Deivalakshmi S., Ko S. 2020. Covid-cxnet: Detecting covid-19 in frontal chest x-ray images using deep learning. arXiv preprint arXiv:2006.13807. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Simonyan K., Zisserman A. 2014. Very deep convolutional networks for large-scale image recognition. arXiv preprint arXiv:1409.1556. [Google Scholar]
  • 44.Huang G, Liu Z, Van Der Maaten L, Weinberger KQ. Densely connected convolutional networks. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2017, p. 4700–8.
  • 45.Szegedy C, Vanhoucke V, Ioffe S, Shlens J, Wojna Z. Rethinking the inception architecture for computer vision. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2016, p. 2818–26.
  • 46.Krizhevsky A. 2014. One weird trick for parallelizing convolutional neural networks. arXiv preprint arXiv:1404.5997. [Google Scholar]
  • 47.Sandler M, Howard A, Zhu M, Zhmoginov A, Chen L-C. Mobilenetv2: Inverted residuals and linear bottlenecks. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2018, p. 4510–20.
  • 48.Szegedy C, Liu W, Jia Y, Sermanet P, Reed S, Anguelov D, Erhan D, Vanhoucke V, Rabinovich A. Going deeper with convolutions. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2015, p. 1–9.
  • 49.Hosseinzadeh Taher M.R., Haghighi F., Feng R., Gotway M.B., Liang J. Domain adaptation and representation transfer, and affordable healthcare and ai for resource diverse global health. Springer; 2021. A systematic benchmarking analysis of transfer learning for medical image analysis; pp. 3–13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Van Horn G, Cole E, Beery S, Wilber K, Belongie S, Mac Aodha O. Benchmarking representation learning for natural world image collections. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition; 2021, p. 12884–93.
  • 51.Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM. Chestx-ray8: Hospital-scale chest x-ray database and benchmarks on weakly-supervised classification and localization of common thorax diseases. In: Proceedings of the IEEE conference on computer vision and pattern recognition; 2017, p. 2097–106.
  • 52.Irvin J, Rajpurkar P, Ko M, Yu Y, Ciurea-Ilcus S, Chute C, Marklund H, Haghgoo B, Ball R, Shpanskaya K et al. Chexpert: A large chest radiograph dataset with uncertainty labels and expert comparison. In: Proceedings of the AAAI conference on artificial intelligence, Vol. 33; 2019, p. 590–7.
  • 53.Deng J., Dong W., Socher R., Li L.-J., Li K., Fei-Fei L. 2009 IEEE conference on computer vision and pattern recognition. Ieee; 2009. Imagenet: A large-scale hierarchical image database; pp. 248–255. [Google Scholar]
  • 54.Caron M., Misra I., Mairal J., Goyal P., Bojanowski P., Joulin A. 2020. Unsupervised learning of visual features by contrasting cluster assignments. arXiv preprint arXiv:2006.09882. [Google Scholar]
  • 55.He K, Fan H, Wu Y, Xie S, Girshick R. Momentum contrast for unsupervised visual representation learning. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition; 2020, p. 9729–38.
  • 56.Chen X., Fan H., Girshick R., He K. 2020. Improved baselines with momentum contrastive learning. arXiv preprint arXiv:2003.04297. [Google Scholar]
  • 57.Kingma D.P., Ba J. 2014. Adam: A method for stochastic optimization. arXiv preprint arXiv:1412.6980. [Google Scholar]
  • 58.Islam M.M., Kashem M.A., Uddin J. Fish survival prediction in an aquatic environment using random forest model. Int J Artif Intell ISSN. 2021;2252(8938):8938. [Google Scholar]
  • 59.Hemdan E.E.-D., Shouman M.A., Karar M.E. 2020. Covidx-net: A framework of deep learning classifiers to diagnose covid-19 in x-ray images. arXiv preprint arXiv:2003.11055. [Google Scholar]
  • 60.Singh D., Kumar V., Yadav V., Kaur M. Deep neural network-based screening model for COVID-19-infected patients using chest X-ray images. Int J Pattern Recognit Artif Intell. 2021;35(03) [Google Scholar]
  • 61.Sahinbas K., Catak F.O. Data science for COVID-19. Elsevier; 2021. Transfer learning-based convolutional neural network for COVID-19 detection with X-ray images; pp. 451–466. [Google Scholar]
  • 62.Jamil M., Hussain I., et al. 2020. Automatic detection of COVID-19 infection from chest X-ray using deep learning. MedRxiv. [Google Scholar]
  • 63.Zheng C., Deng X., Fu Q., Zhou Q., Feng J., Ma H., Liu W., Wang X. 2020. Deep learning-based detection for COVID-19 from chest CT using weak label. MedRxiv. [Google Scholar]

Articles from Informatics in Medicine Unlocked are provided here courtesy of Elsevier

RESOURCES