Langmuir-Based Modeling Produces Steady Two-Dimensional Simulations of Capacitive Deionization via Relaxed Adsorption-Flow Coupling

Johan Nordstrand , Joydeep Dutta †,‡,*
PMCID: PMC8945368  PMID: 35257585

Abstract

graphic file with name la1c02806_0010.jpg

The growing world population creates an ever-increasing demand for fresh drinkable water, and many researchers have discovered the emerging capacitive deionization (CDI) technique to be highly promising for desalination. Traditional modeling of CDI has focused on charge storage in electrical double layers, but recent studies have presented a dynamic Langmuir (DL) approach as a simple and stable alternative. We here demonstrate, for the first time, that a Langmuir-based approach can simulate CDI in multiple dimensions. This provides a new perspective of different physical pictures that could be used to describe the detailed CDI processes. As CDI emerges, effective modeling of large-scale and pilot CDI modules is becoming increasingly important, but such a modeling could also be especially complex. Leveraging the stability of the DL model, we propose an alternative fundamental approach based on relaxed adsorption-flow computations that can dissolve these complexity barriers. Literature data extensively validate the findings, which show how the Langmuir-based approach can simulate and predict how key changes in operational and structural conditions affect the CDI performance. Crucially, the method is tractable for simple simulations of large-scale and structurally complex systems. Put together, this work presents new avenues for approaching the challenges in modeling CDI.

Introduction

As the world population continues to grow, the global need for freshwater provision will steadily increase.1 Due to the tiny fraction (<1%) of readily available freshwater in rivers, lakes, and groundwater,2 it is imperative to tap into the abundantly available saline water bodies by constructing effective desalination technologies,311 such as the emerging capacitive deionization (CDI)1217 technique.

A CDI device comprises two porous electrodes separated by a non-conducting spacer. During desalination, an applied potential precisely extracts salt ions from the water to adsorb them inside the spacious electrodes18 (Figure 1). The process is strongly susceptible to changes in operational and structural conditions, such as the voltage,1921 ion concentration2224 and composition,2535 flow rate,36,37 electrode material,3847 electrode modifications,40,48 device structure,4954 flow mode,55,56 and presence of ion-selective membranes.16,32,57 Also, the ion-concentration dependency makes the intracellular dynamics important.18 Thus, researchers have developed models that capture some of this spatial information, such as in 1D,5860 partial 2D,61 or full 2D.18,62

Figure 1.

Figure 1

Illustration of a flow-between CDI cell.18 The cell comprises two porous electrodes separated by a spacer region. The applied voltage effectively pulls the ions and makes them adsorb onto the electrodes.

Most modern modeling of CDI focuses on how ions are stored in electric double layers (EDLs) on an electrode surface, for example, the modified Donnan (mD)12,13,18,22 model. However, while proponents of such models have argued that this is the only correct approach (ref (13), Figure 12), multiple earlier works have achieved surprisingly accurate results when using a simple Langmuir isotherm to describe equilibrium adsorption.6369 This raised the question of whether the results were merely a coincidence, a numerical effect, or if the Langmuir model has physical relevance for the CDI system. Investigating this, we recently introduced a dynamic Langmuir (DL) model.24 The work presented the surprising results that Langmuir-based modeling could generate both accurate and physically meaningful results, at equilibrium24,30,33 and in the 0D setting.23,70

This work will build on those results by investigating if a Langmuir-based approach can simulate detailed microscopic results or if the approach is only valid on the macroscale. Thus, we derive and implement a DL model in 2D. While earlier authors on 2D modeling have noted that such models can be “unsteady”,18 the early DL approach had a decoupled framework that enhanced the stability in lower dimensions.23,24,70 Thus, we develop two decoupled approaches that could enhance the stability of spatial CDI modeling to demonstrate the underlying stabilizing principles. The first is based on an older circuit-modeling framework, while the other uses the new DL model. Crucially, the work emphasizes the extra stability that the Langmuir-based modeling can bring and its implications for the modeling of upscaled devices.

Theory

Complex and heavily coupled systems can be computationally difficult to solve. Therefore, the theory section will present equations that are required to implement the two decoupled modeling approaches. The first is based on circuit modeling, while the second uses the DL model.

Randles Circuit

As we begin to describe CDI modeling, a simple model that comes to mind is an electrical circuit (Figure 2).71

Figure 2.

Figure 2

Schematic showing the Randles-circuit representation of a CDI system. The capacitance C determines the charge storage capacity, the parallel resistance R2 represents leakages, and the series resistance R1 represents all effects limiting the charging rate.

In the Randles circuit, the capacitive element C firmly determines the maximum charge storage capacity, while the resistive component R2 conversely determines the charge that uselessly leaks past the electrodes. This leaves the R1 series resistance, which collectively describes the ion diffusion, electrode kinetics, and solution resistance. The importance of this picture is that it will allow for a compact description of the CDI charging in 0D.

The equations below show the specific charging dynamics depending on the charging state and the applied voltage (eqs 13).

graphic file with name la1c02806_m001.jpg 1
graphic file with name la1c02806_m002.jpg 2
graphic file with name la1c02806_m003.jpg 3

In these equations, q is the charge on the capacitor and Uext is the total potential. Also, Ui, Ii, and Ri are the potential, current, and resistance across the components i = {1, 2, 3} as shown in Figure 2. Equation 1 stems from the parallel connection, eq 2 is related to the serial connection, and eq 3 represents the conservation of charge. The point here is that the Randles circuit can simulate charging as a self-contained unit. Hence, coupling it with a description of the charge–adsorption relationship would make it possible to describe ion adsorption on the electrodes.72

Dynamic Langmuir Model

An alternative approach to the Randles circuit is the DL model. This work will demonstrate the performance of both within the relaxed-coupling framework.

The original Langmuir-adsorption model describes the adsorption rate of gas molecules on plain surfaces (eq 4).73 The equilibrium version of this expression is the classic Langmuir isotherm (eq 5).

graphic file with name la1c02806_m004.jpg 4
graphic file with name la1c02806_m005.jpg 5

In these equations, θ is the fractional surface coverage, kads and kdes are constants, (1 – θ) corresponds to the fraction of free sites, pA is the partial pressure, KL = kads/kdes is a constant, and subscript e denotes the corresponding equilibrium quantity. The insight here is that we can view adsorption processes as a balance between adsorption and desorption strengths. Also, the total adsorption can be limited by the total effective number of surface sites. These ideas will be important in the following sections.

Here, substituting pA for the concentration c allows the isotherm to incorporate ion adsorption in liquids as well.74 Thus, researchers have subsequently noted that it comfortably describes the concentration dependence of electroadsorption of ions in CDI.6369 Because it works for describing ionic concentrations during CDI, later work successfully altered and extended the classical Langmuir isotherm into a DL model.23,24,30 This means that the DL model can widely and precisely predict CDI performances over a broad range of operational and structural conditions.23,24,30

The DL model starts from a similar idea to the classic Langmuir adsorption but assumes that the core mechanisms have shifted from passive gas adsorption to electrically mediated adsorption of charged species. Here, eq 6 thus shows the adsorption rate for charged species. The corresponding modified expression for net adsorption is shown in eq 7.

graphic file with name la1c02806_m006.jpg 6
graphic file with name la1c02806_m007.jpg 7

In the equations above, c is the concentration, σ is the concentration of charged species (σ = zc, z is the valency), S is the effective number of sites, and subscript ads denotes a corresponding adsorbed quantity. Also, β0 and β1 are constants, and c0 is the initial concentration. The interpretation here is that all charges are driven to absorb by the voltage, but only the net adsorption is valuable for desalination. A variety of effects can cause non-ideal charge efficiency.55 Because these effects have a varying impact, we consider coion expulsion as the major effect, and coions can be present either to neutralize the fixed charge on the electrodes25 (the term with β0) or passively through the solution concentration (the term with β1c0). These effects make the applied voltage expel coions rather than adsorbing the counterions, which reduces the effective number of sites for adsorption.

Here, it is worthwhile to stop and consider the physical picture. Previous models in CDI commonly consider adsorption onto EDLs in the tiny micropores. For instance, the mD model notes that the pore sizes are so small compared to the ions that the EDL heavily overlaps (see the picture in ref (22)), so the main contribution to the capacitance is the tightly packed Stern layer.18 In analogy, the DL model describes the same adsorption but in terms of the effective number of electroadsorption sites that the Stern layer corresponds to.

Based on the expression above, the isotherm expression looks somewhat different in CDI. The expression for the charge storage has the classic Langmuir trend but the expression for the net adsorption must include the losses.

graphic file with name la1c02806_m008.jpg 8
graphic file with name la1c02806_m009.jpg 9
graphic file with name la1c02806_m010.jpg 10

In the equations above, Σ is the specific charge storage, Γ is the specific adsorption, and Λ is the charge efficiency. The conversion parameters listed are the Faraday constant F, the electrode density ρ, and the molar weight Mv. Also, the model parameters A, B, D, λ0, and λ1 (including the variations with ′ and ″) are constants. The reason the external voltage appears in the expressions above is that the sites S are proportional to the applied voltage. Note that the voltage also affects the A parameters through the same relationship (see eqs 7 and 8). The point here is that the expression provides a simple and decoupled method of describing charge and adsorption. For instance, the adsorption is negligible if S < (β0 + β1c0). Thus, when solving for the equilibrium state, the specific charge storage is proportional to the applied voltage, while the specific ion adsorption varies linearly with the applied voltage. Despite the various parameters presented to make the expression decoupled, note that the entire system has only three degrees of freedom.

Previous 2D-coupled CDI research has profitably examined diluted ionic concentration (low c) conditions and shown that 2D spatially resolved modeling can be important to examine in this regime. Therefore, it is interesting to look at what the DL model would correspond to under such conditions (eqs 1113).

graphic file with name la1c02806_m011.jpg 11
graphic file with name la1c02806_m012.jpg 12
graphic file with name la1c02806_m013.jpg 13

The new parameters in these expressions are the constant ks = kadsS and the baseline voltage U0, which are system-dependent parameters. The derivation follows from the full expression by setting the initial concentration to zero. For comparison, low pressure pA in the Langmuir isotherm means KLpA ≪ 1, making the adsorption increase proportionally to the pressure. Similarly, the same effect can be seen in the DL model (see Figure 2 in ref (24)). Here, low concentration means kadsczkdes and β1c0 ≪ β0.

Earlier work has demonstrated that a system-identification method can directly extract all model parameters based on dynamics extracted from the experimental data.23,70,71 However, having equilibrium data could simplify the extraction process. Let us consider experimentally determined conditions as cads,cal (experimental calibration adsorption) and Λcal at Ucal. Then, eq 13 makes U0 = Ucal(1 – Λcal) and, because ċads = 0 at equilibrium, kdes = ksc0(UcalU0)/cads,cal. Thus, ks is the system’s only remaining unknown parameter, which COMSOL’s optimization module confidently extracts using the entire time-series data.

Flow Modeling

The previous sections showed two separate modeling approaches for systematically deducing the local adsorption rate in a typical CDI device. The next step is to couple an adsorption model to a flow-dependent ion-transport model in order to mimic the real-life situation.

Let us, therefore, begin to focus on ion transport. The core principle of transport is the mass transport equation, which states that the change in concentration depends on the difference between the concentration flow in and out of a region. In a well-stirred container, the same principle holds for a bulk volume, which leads to a 0D description of the flow.

graphic file with name la1c02806_m014.jpg 14
graphic file with name la1c02806_m015.jpg 15
graphic file with name la1c02806_m016.jpg 16

Here, j is the ion flux, Q is the flow rate, the total concentration is denoted ctot = c + cads, and ν is the free volume for the water in the device. The idea here is that it is possible to reduce a fully spatial model to lower dimensions by assuming that the concentration is approximately uniform across these dimensions. Hence, the impact of the flow rate depends on how quickly the total volume in the device is exchanged with new water.

An interesting feature of the modeling approach is that it could be implemented in any dimensionality. The adsorption equations (such as eq 12) are completely local, so there is no strict requirement that the model must include certain spatial information. Rather, the spatial dimension that is included allows the model to describe changes in adsorption rate and concentration along that dimension. Thus, a 0D assumes equal adsorption or concentration everywhere. A 1D model assumes equal adsorption and concentration throughout the depth and either length or thickness of the device. Finally, a 2D model would assume homogeneity throughout the depth and a 3D model would include all spatial dimensions. In this work, we will focus on 2D modeling.

Methods

Implementation

As this work’s primary goal is to effectively model 2D systems through a relaxed adsorption-flow coupling, two separate approaches will be provided.

In the first approach, a decoupled method superimposes separately solved adsorption and flow problems. While this may initially seem like a naive approach, the findings in the result section made us realize that it yields surprisingly accurate computations while, crucially, achieving the computational stability required for large-scale modeling. This finding arises largely because the separate adsorption calculation still contains components representing size-dependent effects, such as R1 representing diffusion-limited adsorption rates (Figure 2).

In practice, the Randles circuit could be used to simulate adsorption by fitting its parameters to cell-dependent current data in combination with measuring the charge efficiency. Alternatively, a 0D adsorption-flow approach can fit the Randles circuit to combined the current and adsorption data. Because the model is now fitted, it can predict the 0D time-varying adsorption and simulate the effects of varying operational or structural conditions. Subsequently, having the adsorption prediction means a full-2D COMSOL flow simulation can uniformly use it as an input reaction rate to reliably simulate the relaxed coupled process.

The second approach holistically simulates adsorption and flow together and loosely couples them by softly relaxing the computational complexity. This relaxation is achieved in two ways by practically integrating the DL electroadsorption model (eq 12) into the COMSOL’s reaction module. First, the DL model locally determines the adsorption using ordinary differential equations (ODE), in contrast to previous models that compute potential and ion-concentration distributions in extensive connected partial differential equations (PDE).18,62 The “relaxed” part of relaxed coupling here means that the model is fully 2D while using less spatial information, enhancing computational stability. Second, we simplifyingly assume that the adsorption–desorption constants are uniform throughout the electrode volume, which limits the system’s degrees of freedom. This also lets system-identification methods automatically extract the model parameters.

Simulations

In this work, the 0D computation was implemented in MATLAB (Figures 3 and 4). Within MATLAB, the system-identification toolbox implements a non-linear gray-box estimation (nlgreyest), which allows the user to automatically find the model parameters that yield the best fit to one or more sets of time-series data. For this, it requires a model formulation and fitting data. Here, we use the Randles circuit (Figure 2) with the formulation from eqs 13.

Figure 3.

Figure 3

Equilibrium performance of a flow-between CDI cell, with experimental data from ref (18). Model lines show the fit to data, assuming the relationship between capacitance and adsorption as in eqs 8 and 9. (a) Specific charge storage and salt adsorption. (b) Charge efficiency for the charge and adsorption in (a) (eq 13).

Figure 4.

Figure 4

Using the known capacitance and charge efficiency from Figure 3, a system-identification method can fit the rest of the model parameters to voltage-dependent time-varying performance. Here, the Randles model was fitted to data for all voltages simultaneously. All experimental data from ref (18). (a) Time-varying charge storage. (b) Time-varying total adsorption.

For the coupling, the implementation in COMSOL handles all flow simulations and adsorption-flow couplings using the standard framework for “Reacting Flow in Porous Media”. Thus, the Brinkman equations solve the free- and porous-media flow inside the cell (“Brinkman Equations”), while mass transport equations determine the ionic movement (“Transport of Diluted Species in Porous Media”).

The “Reactions” interface under “Transport of Diluted Species in Porous Media” calculates salt adsorption by treating it as a reaction in which the free ion concentration was converted to the adsorbed ion concentration. The decoupled model uses an “Interpolation Function” to generate a time-dependent adsorption rate based on previously externally calculated adsorption rates. The loosely coupled DL-based model instead uses ODEs and a data envelopment analysis “Domain ODE and DEA” module to implement a distributed differential formulation (eq 12) to track the total adsorption separately from the free concentration. In the latter case, the “Optimization” module automatically generates the best adsorption rate constant based on the uploaded reference data.

Validation Data

The result section extensively examines and validates the model using data from reports in the literature. Among these reports, we primarily considered the seminal work by Hemmatifar et al. because it is the major report on full 2D coupling for CDI using finite-element simulations.18

Results and Discussion

Full 2D modeling often uses extensive sets of coupled PDEs to simulate the device performance.18,62 However, the complexities18 can limit the possible parameter-extraction methods and poor convergence can cause programs to crash. This lack of stability constrains the model’s practical usefulness for feasibly predicting the performance, especially of large-scale and complex CDI structures. In contrast, this section will procedurally demonstrate how partially or fully decoupling the adsorption and flow dramatically enhances stability while maintaining effective modeling accuracy.

Flow-Independent Modeling

Equilibrium Charge and Adsorption

This section seeks to validate the core model before moving to coupled simulations. For the equilibrium case, the DL model predicts that the stored charge increases proportionally with the voltage through the voltage-induced sites. Similarly, the adsorption increases linearly with the voltage but the electrode must overcome a blockage before being able to achieve net adsorption. The results show that the equilibrium DL model accurately fits the equilibrium charge (eq 8, Figure 3a), adsorption (eq 9, Figure 3b), and charge efficiency (eq 10, Figure 3b), without introducing any notion of water flow or ionic transport.

Specifically, the average error magnitude is 1.8 C/g or 1.1 mg/g. The absolute error is fairly constant, so the relative error decreases for higher voltages (e.g., 25 to 8% for the adsorption). The average relative error magnitude is 17.2% for the charge and 14.5% for the adsorption.

Compared to the previous study with the mD model,18 the performance of the DL model is slightly better for describing the experimental results. On the one hand, the mD model includes more details that allow it to describe the performance below 0.4 V in more detail. On the other hand, the linear trends in the DL model are less sensitive to the non-constant capacitive effects at higher voltages, leading to an overall better agreement with data.

Time-Varying Charge and Adsorption

This section continues from the last section by showing that the Randles circuit (in addition to the DL model) can simulate time-dependent performance. The core Randles circuit represents the time-varying adsorption through a resistive element (Figure 2). Thus, flow-dependent effects, such as slow diffusion limiting the adsorption rate, are represented as increased resistance.

Using the equilibrium data in Figure 3 to determine the capacitance and charge efficiency, the Randles circuit directly fits the resistance parameters to accurately capture these experimental time variations (Figure 4). There are some discrepancies between the model and experimental performance, which correspond directly to the non-linear capacitance in the equilibrium data. However, the key point to notice is that the time-dependent trends are accurately captured without introducing detailed coupled flow-adsorption calculations.

Quantitatively, the error in adsorption at equilibrium (120 min) is 13.7% at 0.4 V, 12.2% at 0.6 V, 9.4% at 0.8 V, and 10.3% at 1.0 V. These error rates are stable at around 10% after t = 20 min. The corresponding values for the charge are 25.2% at 0.4 V, 14.6% at 0.6 V, 7.9% at 0.8 V, and 15.8% at 1.0 V. These errors are also somewhat stable during the process.

Compared to previous mD modeling results,18 the modeling here shows better agreement with data. A minor effect comes from the better agreement at the equilibrium level (Figure 3). However, the main reason is that the circuit model is better at describing the overall time scales of charging and adsorption, whereas the mD model predicted too slow charging for the same data set. Hence, the Randles circuit managed well to describe the overall rate-limiting factors (the circuit resistance), and the system-identification process produced great values for the model parameters.

Flow Modeling

FEM software has the advantage of being able to simulate the flow inside the device even if the device structure is complex. In CDI, the relative permeability of the spacer and electrode will have a significant impact on the flow pathway. Figure 5a shows that all flow goes through the spacer regions if that region is just an air gap. This agrees with previous findings.18Figure 5b instead shows that most of the flow passes the electrode if the spacer is less permeable than the electrodes. This is the expected result based on the permeabilities, and a further discussion of similar flow pathways is presented in ref (53).

Figure 5.

Figure 5

(a) Image shows simulated flow based on the cell structure and operational conditions in ref (18). (a, inset) To give a sense of proportion, the inset shows the flow-between cell in (a) with equal x- and y-axis scaling. (b) Simulated flow corresponding to the cellulose spacer in ref (49) being used instead of an air gap as in ref (18). The results suggest that the relative permeability between the spacer and the electrode is crucial for determining the flow path.18

Coupled Modeling

Adsorption Source in 0D

The previous sections demonstrate that it is possible to simulate flow and adsorption separately with reasonable results. However, the adsorption model did not contain any spatial information about what is actually going on in different parts of the device. To add this feature, the simplest way of coupling them to start investigating spatial adsorption/transport processes would be to superimpose the adsorption on the flow simulation.

That is, knowing the total adsorption rate (Figure 4) and the flow distribution (Figure 5), one method of weak coupling is to assume a uniform adsorption distribution across the electrode. This simplified approach neglects detailed localized variations but, because the correct total current and adsorption are used as the input, the model accurately still captures the global effluent-concentration trends (Figure 6a,b). Instead, the neglected detailed variation may cause the model to continue uniformly removing ions even if the adsorption should locally slow down because the concentration is depleted at that location. While this might initially seem like an error, notice that a locally unreasonably low concentration becomes a clear indicator of a concentration shock (Figure 6c). This means the weakly coupled model fulfills the stated goal of identifying concentration shocks while yielding good detailed results for non-starved conditions and being globally accurate.

Figure 6.

Figure 6

(a) Effluent ion concentration for a flow-between CDI cell, experimental data from ref (18). (b) Knowing the total time-dependent adsorption from Figure 4 lets us use this adsorption as an input source in a flow model to predict the effluent ion concentration. (c) For highest voltage (1 V),18 the decoupled model suggests that a uniformly distributed adsorption would abruptly cause complete local depletion after only 2 min, which means the low concentration would severely limit the real system’s effective adsorption rate.

The relative error across all voltages is 5.9%. On a detailed view, the errors are 2.1% at 0.4 V, 2.4% at 0.6 V, 9.4% at 0.8 V, and 8.4% at 1.0 V. This suggests that starvation makes the problem harder to solve accurately. Either way, the point is the model massively reduces the complexity of computing the 2D transport problem and can enable computations that would otherwise cause the simulation to crash.

Compared to the earlier work on the mD model,18 the results here are similar. The experimental results suggest that the lowest concentration is reached at the same time independent of the initial concentration, and the new model captures this part slightly better. As for the experimental data, it is also a bit smoother in the 20–80 min timeframe, which could be linked to the enhanced stability.

Adsorption ODE and Optimization

For the next step, providing partial coupling between the adsorption and the spatial information could improve the detailed resolution and predictive value for new operations and systems.

Let us, therefore, focus on the spatially resolved DL model. The advantage of the DL model is that it uses ODEs instead of PDEs like the previous models (eq 12). This means the adsorption rate depends only on the local concentration and adsorption. Thus, the COMSOL module for chemical reactions can be used to smoothly integrate the spatially resolved DL model with a water-flow simulation, which means that the salt adsorption in CDI is effectively treated as a chemical reaction in a porous catalyst. This also allows the COMSOL’s Optimization module to automatically estimate the unknown parameters from the calibration data.

An interesting feature in systems with lower ionic concentrations is that the adsorption phase becomes slower,18 which can be seen in the experimental data of Figure 7a from the desalination and regeneration phases. Here, previous 0D work in the DL model could not capture this effect23,70 but the spatially resolved DL model accurately captures this effect because the ion concentration now locally determines the DL adsorption rate (eq 12, Figure 7). Crucially, this demonstrates that a Langmuir-based approach can be relevant for modeling CDI in 2D and has distinct advantages over comparable methods.

Figure 7.

Figure 7

(a) Model fit of the spatially integrated DL model (eq 12) to experimental data from ref (18). (b) Simulated ion-concentration distribution inside the cell at the point of the lowest effluent concentration. (c) Fitted DL model accurately predicts the effluent concentration at 0.4 V for the same device.

Compared to the previous work on the mD model,18 both models have good performance but seem to be a bit too slow at reaching the lowest/highest points. The mD model was symmetrically slower in both the desalination and regeneration phases, while the DL model just underestimated the speed in the regeneration phase. Similar issues with the time scale can also be seen in other works, such as ref (37).

Scaling Up CDI

Because loose coupling increases computational stability, the two presented methods open up modeling studies of complex CDI architectures. Consider an architecture with two stacked cells of the type investigated previously, with open inlet, outlet, and separator regions (the same as refs (53) and (75)). Due to the complex flows inside the system, such a setup is a good application for a model with relaxed coupling to boost stability.

For the decoupled circuit model, the total 0D adsorption relates to a single-cell calibration because two identical cells adsorb about twice as much as one. This principle readily extends to other variations for which the 0D adsorption can be predicted, such as voltage, ion concentration, and electrode asymmetry. Similarly, changes in flow rates or flow patterns are computed separately.

With more spatial information, the fitted DL model from Figure 7c steadily simulates the behavior of the two-cell systems (Figure 8a,b). Notably, the pressure drop in the parallel system is only a quarter of the corresponding serial pressure drop,53 while the difference in desalination performance is minuscule (Figure 8c). This means the parallel system requires less pumping pressure for the same output, which makes it energetically superior. Figure 8c also interestingly shows that the global effluent-concentration performance for the single-cell module is practically the same as the corresponding larger system, where the flow rate is doubled as well as the size. Thus, the performance depends mainly on the global replacement rate Qcell (Q is the flow rate and νcell is the cell-free volume), which means a 0D model could also be effective for predicting the non-starved performance of larger modular systems.

Figure 8.

Figure 8

Simulation uses a fitting of the DL model to 0.4 V data from the flow-between device in ref (18), for a single cell. The simulation then evaluates the performance ofo a serial/parallel module with twice the size and flow rate. Note that the arrows show the flow directions, which are through the stacks and uniform across the length of the devices. (a,b) Module’s interior ion concentration at the point of lowest effluent concentration, for a serial and parallel flow, respectively. (c) Effluent concentration for the experimental single-cell module and the simulated two-cell serial/parallel modules with the double-flow rate.

Limitations and Prospects

This work has found two approaches to beneficially relax complexities of 2D modeling in CDI, and below follows a discussion on the limitations and prospects of these methods.

One may reflect that the cell’s interior structure is required to realistically calculate ion adsorption. This is partially true because modeling adsorption through 0D calculations should normally miss system aspects related to size, such as diffusion-limited adsorption rates at low ionic concentrations. However, as the Randles series resistance represents all rate-limiting effects, the resistance varies depending on the operating conditions, meaning that the 0D adsorption model accurately fits the adsorption dynamics even at low ionic concentrations. Thus, more accurately, the practical limitation of the 0D model is that it neglects the resistance differences between starved and normal conditions, which could reduce the predictive value over large variations in the inlet concentration. One way of handling this could be to adopt a concentration-dependent resistance formulation.76

Another feature that separates the presented approach is that both models assume that the governing equations are the same throughout the cell. However, some specific changes, such as increasing the electrode thickness, may non-linearly alter the total adsorption, which corresponds to a change in the per-volume adsorption and desorption constants. This means researchers implementing this method should consider if, and how, changes in operational and structural conditions affect the system parameters. The current work has explicitly investigated global variations in voltage and flow rate, local variations in ion concentrations, and cell-count upscaling. For future work, literature reports additionally provide ample inspiration for how to address changes in voltage,23,24 flow rate,23 concentration,23,24 electrode size,24 electrode surface modifications,24 and multi-ion solutions.30

Conclusions

Because interest in the applications of CDI is growing, 2D-modeling of large-scale interconnected CDI devices is becoming increasingly important. The dominant 2D-modeling approaches today employ computationally complex 2D-PDE systems for predicting ion adsorption in small devices.18,62 Therefore, we have proposed and validated a relaxed adsorption-flow coupling approach. The relaxation allows simulations to reach the state-of-the-art modeling accuracy with enhanced stability that greatly expands its tractability for realistic large-scale modeling. This work also demonstrated that a Langmuir-based approach can simulate internal and global dynamics of the desalination process with CDI devices.

The present work discovered two routes to achieving relaxed 2D coupling. In the first approach, a 0D method separately calculates the ion adsorption, which is then uniformly integrated into a general flow simulation. Experimental data show that the model generates surprisingly accurate global results and can reliably identify concentration shocks that limit the effective adsorption rate. In the second approach, a localized steady ODE model for adsorption holistically combines with the background water-flow simulation. Thus, the modeling structure firmly relaxes the calculations, which means it reliably extends to large-scale CDI systems with varying concentrations and complex flows.

Acknowledgments

The authors would like to thank the Swedish Research Council (Diary no. 2018-05387) and J. Gust. Richert Foundation (Diary no. 2020-00584) for funding the work.

The authors declare no competing financial interest.

Notes

The data and COMSOL model underlying this study are openly available in Mendeley Data at Nordstrand, Johan (2022), “COMSOL Model for: Langmuir-Based Modeling Produces Steady Two-Dimensional Simulations of Capacitive Deionization via Relaxed Adsorption-Flow Coupling”, Mendeley Data, V1, doi: 10.17632/b55r8ybmdp.1.

References

  1. WWAP (United Nations World Water Assessment Programme)/UN-Water . United Nations World Water Development Report 2018 Nature-Based Solutions Water, 2018.
  2. Gleick P. H.Water in Crisis: A Guide to the World’s Fresh Water Resources; Oxford University Press: Oxford, 1993. [Google Scholar]
  3. Ghaffour N.; Missimer T. M.; Amy G. L. Technical review and evaluation of the economics of water desalination: Current and future challenges for better water supply sustainability. Desalination 2013, 309, 197–207. 10.1016/j.desal.2012.10.015. [DOI] [Google Scholar]
  4. Alghoul M. A.; Poovanaesvaran P.; Sopian K.; Sulaiman M. Y. Review of brackish water reverse osmosis (BWRO) system designs. Renewable Sustainable Energy Rev. 2009, 13, 2661–2667. 10.1016/j.rser.2009.03.013. [DOI] [Google Scholar]
  5. Islam M. S.; Sultana A.; Saadat A. H. M.; Islam M. S.; Shammi M.; Uddin M. K. Desalination Technologies for Developing Countries: A Review. J. Sci. Res. 2018, 10, 77–97. 10.3329/jsr.v10i1.33179. [DOI] [Google Scholar]
  6. Lee K. P.; Arnot T. C.; Mattia D. A review of reverse osmosis membrane materials for desalination-Development to date and future potential. J. Membr. Sci. 2011, 370, 1–22. 10.1016/j.memsci.2010.12.036. [DOI] [Google Scholar]
  7. Greenlee L. F.; Lawler D. F.; Freeman B. D.; Marrot B.; Moulin P.; Ce P. Reverse osmosis desalination: Water sources, technology, and today’s challenges. Water Res. 2009, 43, 2317–2348. 10.1016/j.watres.2009.03.010. [DOI] [PubMed] [Google Scholar]
  8. Strathmann H. Electrodialysis, a mature technology with a multitude of new applications. DES 2010, 264, 268–288. 10.1016/j.desal.2010.04.069. [DOI] [Google Scholar]
  9. Mcginnis R. L.; Elimelech M. Energy requirements of ammonia-carbon dioxide forward osmosis desalination. Desalination 2007, 207, 370–382. 10.1016/j.desal.2006.08.012. [DOI] [Google Scholar]
  10. Kim T.; Gorski C. A.; Logan B. E. Low Energy Desalination Using Battery Electrode Deionization. Environ. Sci. Technol. Lett. 2017, 4, 444–449. 10.1021/acs.estlett.7b00392. [DOI] [Google Scholar]
  11. Rommerskirchen A.; Ohs B.; Hepp K. A.; Femmer R.; Wessling M. Modeling Continuous Flow-Electrode Capacitive Deionization Processes with Ion-Exchange Membranes. J. Membr. Sci. 2018, 546, 188–196. 10.1016/j.memsci.2017.10.026. [DOI] [Google Scholar]
  12. Porada S.; Zhao R.; Van Der Wal A.; Presser V.; Biesheuvel P. M. Review on the Science and Technology of Water Desalination by Capacitive Deionization. Prog. Mater. Sci. 2013, 58, 1388–1442. 10.1016/j.pmatsci.2013.03.005. [DOI] [Google Scholar]
  13. Suss M. E.; Porada S.; Sun X.; Biesheuvel P. M.; Yoon J.; Presser V. Water Desalination via Capacitive Deionization: What Is It and What Can We Expect from It?. Energy Environ. Sci. 2015, 8, 2296–2319. 10.1039/C5EE00519A. [DOI] [Google Scholar]
  14. Anderson M. A.; Cudero A. L.; Palma J. Capacitive Deionization as an Electrochemical Means of Saving Energy and Delivering Clean Water. Comparison to Present Desalination Practices: Will It Compete?. Electrochim. Acta 2010, 55, 3845–3856. 10.1016/j.electacta.2010.02.012. [DOI] [Google Scholar]
  15. Yu T.-H.; Shiu H.-Y.; Lee M.; Chiueh P.-T.; Hou C.-H. Life Cycle Assessment of Environmental Impacts and Energy Demand for Capacitive Deionization Technology. Desalination 2016, 399, 53–60. 10.1016/j.desal.2016.08.007. [DOI] [Google Scholar]
  16. Długołęcki P.; van der Wal A. Energy Recovery in Membrane Capacitive Deionization. Environ. Sci. Technol. 2013, 47, 4904–4910. 10.1021/es3053202. [DOI] [PubMed] [Google Scholar]
  17. Han L.; Karthikeyan K. G.; Gregory K. B. Energy Consumption and Recovery in Capacitive Deionization Using Nanoporous Activated Carbon Electrodes. J. Electrochem. Soc. 2015, 162, E282–E288. 10.1149/2.0431512jes. [DOI] [Google Scholar]
  18. Hemmatifar A.; Stadermann M.; Santiago J. G. Two-Dimensional Porous Electrode Model for Capacitive Deionization. J. Phys. Chem. C 2015, 119, 24681–24694. 10.1021/acs.jpcc.5b05847. [DOI] [Google Scholar]
  19. Demirer O. N.; Naylor R. M.; Rios Perez C. A.; Wilkes E.; Hidrovo C. Energetic Performance Optimization of a Capacitive Deionization System Operating with Transient Cycles and Brackish Water. Desalination 2013, 314, 130–138. 10.1016/j.desal.2013.01.014. [DOI] [Google Scholar]
  20. Jande Y. A. C.; Kim W. S. Desalination Using Capacitive Deionization at Constant Current. Desalination 2013, 329, 29–34. 10.1016/j.desal.2013.08.023. [DOI] [Google Scholar]
  21. Wang L.; Lin S. Membrane Capacitive Deionization with Constant Current vs Constant Voltage Charging: Which Is Better?. Environ. Sci. Technol. 2018, 52, 4051–4060. 10.1021/acs.est.7b06064. [DOI] [PubMed] [Google Scholar]
  22. Biesheuvel P. M.; Porada S.; Levi M.; Bazant M. Z. Attractive Forces in Microporous Carbon Electrodes for Capacitive Deionization. J. Solid State Electrochem. 2014, 18, 1365–1376. 10.1007/s10008-014-2383-5. [DOI] [Google Scholar]
  23. Nordstrand J.; Laxman K.; Myint M. T. Z.; Dutta J. An Easy-to-Use Tool for Modeling the Dynamics of Capacitive Deionization. J. Phys. Chem. A 2019, 123, 6628–6634. 10.1021/acs.jpca.9b05503. [DOI] [PubMed] [Google Scholar]
  24. Nordstrand J.; Dutta J. Dynamic Langmuir Model: A Simpler Approach to Modeling Capacitive Deionization. J. Phys. Chem. C 2019, 123, 16479–16485. 10.1021/acs.jpcc.9b04198. [DOI] [PubMed] [Google Scholar]
  25. Biesheuvel P. M.Activated Carbon Is an Electron-Conducting Amphoteric Ion Adsorbent. 2015, arXiv:1509.06354. [Google Scholar]
  26. Hassanvand A.; Chen G. Q.; Webley P. A.; Kentish S. E. A Comparison of Multicomponent Electrosorption in Capacitive Deionization and Membrane Capacitive Deionization. Water Res. 2018, 131, 100–109. 10.1016/j.watres.2017.12.015. [DOI] [PubMed] [Google Scholar]
  27. Chen Z.; Zhang H.; Wu C.; Wang Y.; Li W. A study of electrosorption selectivity of anions by activated carbon electrodes in capacitive deionization. Desalination 2015, 369, 46–50. 10.1016/j.desal.2015.04.022. [DOI] [Google Scholar]
  28. Zhao R.; van Soestbergen M.; Rijnaarts H. H. M.; van der Wal A.; Bazant M. Z.; Biesheuvel P. M. Time-Dependent Ion Selectivity in Capacitive Charging of Porous Electrodes. J. Colloid Interface Sci. 2012, 384, 38–44. 10.1016/j.jcis.2012.06.022. [DOI] [PubMed] [Google Scholar]
  29. Seo S.-J.; Jeon H.; Lee J. K.; Kim G.-Y.; Park D.; Nojima H.; Lee J.; Moon S.-H. Investigation on removal of hardness ions by capacitive deionization (CDI) for water softening applications. Water Res. 2010, 44, 2267–2275. 10.1016/j.watres.2009.10.020. [DOI] [PubMed] [Google Scholar]
  30. Nordstrand J.; Dutta J. Simplified Prediction of Ion Removal in Capacitive Deionization of Multi-Ion Solutions. Langmuir 2020, 36, 1338–1344. 10.1021/acs.langmuir.9b03571. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Tang W.; Kovalsky P.; Cao B.; Waite T. D. Investigation of Fluoride Removal from Low-Salinity Groundwater by Single-Pass Constant-Voltage Capacitive Deionization. Water Res. 2016, 99, 112–121. 10.1016/j.watres.2016.04.047. [DOI] [PubMed] [Google Scholar]
  32. Tang W.; He D.; Zhang C.; Waite T. D. Optimization of Sulfate Removal from Brackish Water by Membrane Capacitive Deionization (MCDI). Water Res. 2017, 121, 302–310. 10.1016/J.WATRES.2017.05.046. [DOI] [PubMed] [Google Scholar]
  33. Nordstrand J.; Dutta J. Predicting and Enhancing the Ion Selectivity in Multi-Ion Capacitive Deionization. Langmuir 2020, 36, 8476–8484. 10.1021/acs.langmuir.0c00982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Fan C.-S.; Tseng S.-C.; Li K.-C.; Hou C.-H. Electro-Removal of Arsenic(III) and Arsenic(V) from Aqueous Solutions by Capacitive Deionization. J. Hazard. Mater. 2016, 312, 208–215. 10.1016/j.jhazmat.2016.03.055. [DOI] [PubMed] [Google Scholar]
  35. Tang W.; Kovalsky P.; He D.; Waite T. D. Fluoride and Nitrate Removal from Brackish Groundwaters by Batch-Mode Capacitive Deionization. Water Res. 2015, 84, 342–349. 10.1016/j.watres.2015.08.012. [DOI] [PubMed] [Google Scholar]
  36. Wang C.; Song H.; Zhang Q.; Wang B.; Li A. Parameter Optimization Based on Capacitive Deionization for Highly Efficient Desalination of Domestic Wastewater Biotreated Effluent and the Fouled Electrode Regeneration. Desalination 2015, 365, 407–415. 10.1016/j.desal.2015.03.025. [DOI] [Google Scholar]
  37. Mutha H. K.; Cho H. J.; Hashempour M.; Wardle B. L.; Thompson C. V.; Wang E. N. Salt Rejection in Flow-between Capacitive Deionization Devices. Desalination 2018, 437, 154–163. 10.1016/j.desal.2018.03.008. [DOI] [Google Scholar]
  38. Xu X.; Li J.; Li Y.; Ni B.; Liu X.; Pan L.. Selection of Carbon Electrode Materials. Interface Science and Technology; Elsevier Ltd.: San Diego, 2018; Vol. 24, pp 65–83. [Google Scholar]
  39. Laxman K.; Myint M. T. Z.; Bourdoucen H.; Dutta J.; Dutta J. Enhancement in Ion Adsorption Rate and Desalination Efficiency in a Capacitive Deionization Cell through Improved Electric Field Distribution Using Electrodes Composed of Activated Carbon Cloth Coated with Zinc Oxide Nanorods. Appl. Mater. Interfaces 2014, 6, 10113–10120. 10.1021/am501041t. [DOI] [PubMed] [Google Scholar]
  40. Laxman K.; Myint M. T. Z.; Khan R.; Pervez T.; Dutta J. Improved Desalination by Zinc Oxide Nanorod Induced Electric Field Enhancement in Capacitive Deionization of Brackish Water. Desalination 2015, 359, 64–70. 10.1016/j.desal.2014.12.029. [DOI] [Google Scholar]
  41. Laxman K.; Myint M. T. Z.; Khan R.; Pervez T.; Dutta J. Effect of a Semiconductor Dielectric Coating on the Salt Adsorption Capacity of a Porous Electrode in a Capacitive Deionization Cell. Electrochim. Acta 2015, 166, 329–337. 10.1016/j.electacta.2015.03.049. [DOI] [Google Scholar]
  42. Suss M. E.; Baumann T. F.; Worsley M. A.; Rose K. A.; Jaramillo T. F.; Stadermann M.; Santiago J. G. Impedance-Based Study of Capacitive Porous Carbon Electrodes with Hierarchical and Bimodal Porosity. J. Power Sources 2013, 241, 266–273. 10.1016/j.jpowsour.2013.03.178. [DOI] [Google Scholar]
  43. Suss M. E.; Baumann T. F.; Bourcier W. L.; Spadaccini C. M.; Rose K. A.; Santiago J. G.; Stadermann M. Capacitive Desalination with Flow-through Electrodes. Energy Environ. Sci. 2012, 5, 9511. 10.1039/c2ee21498a. [DOI] [Google Scholar]
  44. Porada S.; Bryjak M.; Van Der Wal A.; Biesheuvel P. M. Effect of Electrode Thickness Variation on Operation of Capacitive Deionization. Electrochim. Acta 2012, 75, 148–156. 10.1016/j.electacta.2012.04.083. [DOI] [Google Scholar]
  45. Li H.; Zou L.; Pan L.; Sun Z. Using Graphene Nano-Flakes as Electrodes to Remove Ferric Ions by Capacitive Deionization. Sep. Purif. Technol. 2010, 75, 8–14. 10.1016/j.seppur.2010.07.003. [DOI] [Google Scholar]
  46. Wang G.; Ling Y.; Qian F.; Yang X.; Liu X.-X.; Li Y. Enhanced Capacitance in Partially Exfoliated Multi-Walled Carbon Nanotubes. J. Power Sources 2011, 196, 5209–5214. 10.1016/j.jpowsour.2011.02.019. [DOI] [Google Scholar]
  47. Vafakhah S.; Guo L.; Sriramulu D.; Huang S.; Saeedikhani M.; Yang H. Y. Efficient Sodium-Ion Intercalation into the Freestanding Prussian Blue/Graphene Aerogel Anode in a Hybrid Capacitive Deionization System. ACS Appl. Mater. Interfaces 2019, 11, 5989–5998. 10.1021/acsami.8b18746. [DOI] [PubMed] [Google Scholar]
  48. Gao X.; Omosebi A.; Landon J.; Liu K. Enhancement of Charge Efficiency for a Capacitive Deionization Cell Using Carbon Xerogel with Modified Potential of Zero Charge. Electrochem. Commun. 2014, 39, 22–25. 10.1016/j.elecom.2013.12.004. [DOI] [Google Scholar]
  49. Laxman K.; Husain A.; Nasser A.; Al Abri M.; Dutta J. Tailoring the Pressure Drop and Fluid Distribution of a Capacitive Deionization Device. Desalination 2019, 449, 111–117. 10.1016/j.desal.2018.10.021. [DOI] [Google Scholar]
  50. Santos C.; Lado J. J.; García-Quismondo E.; Soria J.; Palma J.; Anderson M. A. Maximizing Volumetric Removal Capacity in Capacitive Deionization by Adjusting Electrode Thickness and Charging Mode. J. Electrochem. Soc. 2018, 165, E294–E302. 10.1149/2.1011807jes. [DOI] [Google Scholar]
  51. Rommerskirchen A.; Linnartz C. J.; Müller D.; Willenberg L. K.; Wessling M. Energy Recovery and Process Design in Continuous Flow-Electrode Capacitive Deionization Processes. ACS Sustainable Chem. Eng. 2018, 6, 13007–13015. 10.1021/acssuschemeng.8b02466. [DOI] [Google Scholar]
  52. Tang W.; Liang J.; He D.; Gong J.; Tang L.; Liu Z.; Wang D.; Zeng G. Various Cell Architectures of Capacitive Deionization: Recent Advances and Future Trends. Water Res. 2019, 150, 225–251. 10.1016/j.watres.2018.11.064. [DOI] [PubMed] [Google Scholar]
  53. Nordstrand J.; Dutta J. Design Principles for Enhanced Up-Scaling of Flow-through Capacitive Deionization for Water Desalination. Desalination 2021, 500, 114842. 10.1016/j.desal.2020.114842. [DOI] [Google Scholar]
  54. Tan C.; He C.; Fletcher J.; Waite T. D. Energy Recovery in Pilot Scale Membrane CDI Treatment of Brackish Waters. Water Res. 2020, 168, 115146. 10.1016/j.watres.2019.115146. [DOI] [PubMed] [Google Scholar]
  55. Hawks S. A.; Knipe J. M.; Campbell P. G.; Loeb C. K.; Hubert M. A.; Santiago J. G.; Stadermann M. Quantifying the Flow Efficiency in Constant-Current Capacitive Deionization. Water Res. 2018, 129, 327–336. 10.1016/j.watres.2017.11.025. [DOI] [PubMed] [Google Scholar]
  56. Shang X.; Cusick R. D.; Smith K. C. A Combined Modeling and Experimental Study Assessing the Impact of Fluid Pulsation on Charge and Energy Efficiency in Capacitive Deionization. J. Electrochem. Soc. 2017, 164, E536–E547. 10.1149/2.0841714jes. [DOI] [Google Scholar]
  57. Choi J.-H.; Yoon D.-J. The Maximum Allowable Charge for Operating Membrane Capacitive Deionization without Electrode Reactions. Sep. Purif. Technol. 2019, 215, 125–133. 10.1016/j.seppur.2019.01.003. [DOI] [Google Scholar]
  58. Rica R. A.; Ziano R.; Salerno D.; Mantegazza F.; Bazant M. Z.; Brogioli D. Electro-Diffusion of Ions in Porous Electrodes for Capacitive Extraction of Renewable Energy from Salinity Differences. Electrochim. Acta 2013, 92, 304–314. 10.1016/j.electacta.2013.01.063. [DOI] [Google Scholar]
  59. Guyes E. N.; Shocron A. N.; Simanovski A.; Biesheuvel P. M.; Suss M. E. A One-Dimensional Model for Water Desalination by Flow-through Electrode Capacitive Deionization. Desalination 2017, 415, 8–13. 10.1016/j.desal.2017.03.013. [DOI] [Google Scholar]
  60. Perez C. A. R.; Demirer O. N.; Clifton R. L.; Naylor R. M.; Hidrovo C. H. Macro Analysis of the Electro-Adsorption Process in Low Concentration NaCl Solutions for Water Desalination Applications. J. Electrochem. Soc. 2013, 160, E13–E21. 10.1149/2.025303jes. [DOI] [Google Scholar]
  61. Porada S.; Borchardt L.; Oschatz M.; Bryjak M.; Atchison J. S.; Keesman K. J.; Kaskel S.; Biesheuvel P. M.; Presser V. Direct Prediction of the Desalination Performance of Porous Carbon Electrodes for Capacitive Deionization. Energy Environ. Sci. 2013, 6, 3700–3712. 10.1039/c3ee42209g. [DOI] [Google Scholar]
  62. Nordstrand J.; Dutta J. A new automated model brings stability to finite-element simulations of capacitive deionization. Nano Sel. 2021, 1–15. 10.1002/nano.202100270. [DOI] [Google Scholar]
  63. Li H.; Lu T.; Pan L.; Zhang Y.; Sun Z. Electrosorption Behavior of Graphene in NaCl Solutions. J. Mater. Chem. 2009, 19, 6773–6779. 10.1039/b907703k. [DOI] [Google Scholar]
  64. Li H.; Pan L.; Lu T.; Zhan Y.; Nie C.; Sun Z. A Comparative Study on Electrosorptive Behavior of Carbon Nanotubes and Graphene for Capacitive Deionization. J. Electroanal. Chem. 2011, 653, 40–44. 10.1016/j.jelechem.2011.01.012. [DOI] [Google Scholar]
  65. Wang L.; Wang M.; Huang Z.-H.; Cui T.; Gui X.; Kang F.; Wang K.; Wu D. Capacitive Deionization of NaCl Solutions Using Carbon Nanotube Sponge Electrodes. J. Mater. Chem. 2011, 21, 18295. 10.1039/c1jm13105b. [DOI] [Google Scholar]
  66. Ryoo M.-W.; Kim J.-H.; Seo G. Role of Titania Incorporated on Activated Carbon Cloth for Capacitive Deionization of NaCl Solution. J. Colloid Interface Sci. 2003, 264, 414–419. 10.1016/S0021-9797(03)00375-8. [DOI] [PubMed] [Google Scholar]
  67. Gabelich C. J.; Tran T. D.; Suffet I. H. M. Electrosorption of Inorganic Salts from Aqueous Solution Using Carbon Aerogels. Environ. Sci. Technol. 2002, 36, 3010–3019. 10.1021/es0112745. [DOI] [PubMed] [Google Scholar]
  68. Li H.; Pan L.; Zhang Y.; Zou L.; Sun C.; Zhan Y.; Sun Z. Kinetics and Thermodynamics Study for Electrosorption of NaCl onto Carbon Nanotubes and Carbon Nanofibers Electrodes. Chem. Phys. Lett. 2010, 485, 161–166. 10.1016/j.cplett.2009.12.031. [DOI] [Google Scholar]
  69. Wang G.; Qian B.; Dong Q.; Yang J.; Zhao Z.; Qiu J. Highly Mesoporous Activated Carbon Electrode for Capacitive Deionization. Sep. Purif. Technol. 2013, 103, 216–221. 10.1016/j.seppur.2012.10.041. [DOI] [Google Scholar]
  70. Nordstrand J.; Dutta J. Flexible modeling and control of capacitive-deionization processes through a linear-state-space dynamic Langmuir model. npj Clean Water 2021, 4, 1–7. 10.1038/s41545-020-00094-y. [DOI] [Google Scholar]
  71. Nordstrand J.; Dutta J. An Extended Randles Circuit and a Systematic Model-Development Approach for Capacitive Deionization. J. Electrochem. Soc. 2021, 168, 013502. 10.1149/1945-7111/abd82f. [DOI] [Google Scholar]
  72. Nordstrand J.; Dutta J. Basis and Prospects of Combining Electroadsorption Modeling Approaches for Capacitive Deionization. Physics 2020, 2, 309–324. 10.3390/physics2020016. [DOI] [Google Scholar]
  73. Langmuir I. The Adsorption of Gases on Plane Surfaces of Glass, Mica and Platinum. J. Am. Chem. Soc. 1918, 40, 1361–1403. 10.1021/ja02242a004. [DOI] [Google Scholar]
  74. Azizian S.; Eris S.; Wilson L. D. Re-Evaluation of the Century-Old Langmuir Isotherm for Modeling Adsorption Phenomena in Solution. Chem. Phys. 2018, 513, 99–104. 10.1016/j.chemphys.2018.06.022. [DOI] [Google Scholar]
  75. Nordstrand J.; Joydeep D.. Relaxed Adsorption-Flow Coupling Enables Stable COMSOL Multiphysics Modeling of Upscaled Capacitive Deionization. COMSOL Conference 2020 Grenoble; COMSOL: Grenoble, 2020.
  76. Ramachandran A.; Oyarzun D. I.; Hawks S. A.; Campbell P. G.; Stadermann M.; Santiago J. G. Comments on “Comparison of Energy Consumption in Desalination by Capacitive Deionization and Reverse Osmosis”. Desalination 2019, 461, 30–36. 10.1016/j.desal.2019.03.010. [DOI] [Google Scholar]