Skip to main content
. 2022 Mar 8;11:e75568. doi: 10.7554/eLife.75568

Table 1. Summary of cryogenic electron microscopy (cryo-EM) data collection and image processing parameters.

Dataset RyR1ACP/EGTA closed RyR1ACP/Ca22+A inactivated RyR1ACP/Ca22+A inactivated class1 RyR1ACP/Ca22+A inactivated class2 RyR1ACP/Ca22+A inactivated class3 RyR1ACP/Ca22+A inactivated CDTM RyR1ACP/Ca22+A open RyR1ACP/Ca22+A open CDTM RyR1ACP/Ca22+B inactivated RyR1ACP/Ca22+B open
Data acquisition
Microscope/detector Krios/K2 Krios/K3 Krios/K2
Voltage (kV) 300 300 300
Magnification 130,000 81,000 130,000
Defocus range (μm) –1.2 to –2.2 –1.25 to –2.5 –1.25 to –2.5
Pixel size (Å) (calibrated) 1.06 (1.07) 1.08 (1.105) 1.06 (1.07)
Total electron dose (e/Å2) 70 70 70
Exposure time (s) 12 4.4 14
Number of frames 60 50 50
Total number of Micrographs 1959 10,002 1346
Image processing
Total number of particles selected 52,856 311,258 35,554
Final number of particles 21,551 90,530 79,277 159,444 71,499 90,530 14,012 14,012 14,669 4160
Reconstruction symmetry C4 C4 C1 C1 C1 C4 C4 C4 C4 C4
Map resolution, FSC (0.143) (Å) (symmetry expanded map) 4.3 (3.9) 3.8 (3.5) 3.7 3.3 3.8 3.5 4.6 (4.0) 4.4 4.1 (3.8) 5.8
Map sharpening B-factor (Å2) (symmetry expanded map) –132 –150 (–144) –125 –102 –123 –142 –168 (–135) –144 –111(–89) –148
EMDB ID 22616 22597 25828 25831 25830 25832 25828* 25829 25829* 25833 -
*

Submitted as an additional map.