Abstract
Background
Management of mental workload is a key aspect of safety in anaesthesia but there is no gold-standard tool to assess mental workload, risking confusion in clinical and research use of such tools.
Objective
This review assessed currently used mental workload assessment tools.
Methods
A systematic literature search was performed on the following electronic databases; Cochrane, EMBASE, MEDLINE, SCOPUS and Web of Science. Screening and data extraction were performed individually by two authors. We included primary published papers focusing on mental workload assessment tools in anaesthesia.
Results
A total of 2331 studies were screened by title, 32 by full text and 24 studies met the inclusion criteria. Six mental workload measurement tools were observed across included studies. Reliability for the Borg rating scales and Vibrotactile device was reported in two individual studies. The rest of the studies did not record reliability of the tool measurements used. Borg rating scales, NASA-TLX and task-oriented mental work load measurements are subjective, easily available, readily accessible and takes a few minutes to complete. However, the vibrotactile and eye-tracking methods are objective, require more technical involvement, considerable time for the investigator and moderately expensive, impacting their potential use.
Conclusion
We found that the measurement of mental workload in anaesthesia is an emerging field supporting patient and anaesthetist safety. The self-reported measures have the best evidence base.
Keywords: workload, over load, anaesthesia, anaesthetist
Introduction
Mental workload has been defined in terms of level of attention and resources required to meet objective and subjective performance criteria of an individual task, which may be mediated by task demands, external support and past experience.1 It has been identified as key performance factor in various complex working environments.2 Anaesthetists work in an environment where mental workload may impact on safety through slips, lapses and conflict.3 Managed workload may have an impact on job satisfaction within the operating team and provide cost-effective care. Studies4 5 have demonstrated that workload may lead to increase anaesthetist stress (in part an imbalance between workload and resources),6 burnout and fatigue. Both aviation and nuclear industries report associations between mental workload, system performance and safety.7 8
Mitigating effects of workload/capacity mismatch requires understanding of temporal, individual and contextual-sensitive changes in workload. However, although it might relatively be easy to identify times of increased or reduced mental workload, it is not a trivial issue to reliably quantify this.9 Several methods have been proposed to measure anaesthesia workload based on metrics used in other industries, but to date none of the assessment tools available has been considered standard for use across healthcare. While it is unlikely that any single tool will ever be optimal for all situations, it is important for researchers and practitioners to understand what various tools can and cannot be expected to do when used or reported in studies.
Current mental workload measurements are conceived from four parallel conceptual frameworks (scoring/task oriented, task performance, response time capabilities and physiological changes). Criteria of methods are detailed intable 1. Subjective task-oriented methodologies are multidimensional constructs of subscales that include: mental, physical, temporal demand, frustrations, effort and performance. The theory of such tools is that combination of specific elements is more likely to describe the workload experienced by most operators doing the tasks7; and most importantly, the operator is the best individual to rank/score how difficult the task is perceived. Other tools work from the premise that if a primary (clinical) task is associated with high level of workload, limited spare mental capacity will be available. This will be observed by delays in reacting to a secondary task analogous to a computer slowing down if it has insufficient memory or processing power. It may also be observed in error rates or time taken for the primary tasks themselves. Physiological measurement tools assume that increases in mental workload are associated with observable changes in physiology, mediated via the autonomic nervous system.10 This review assesses the theoretical framework and supporting data for currently used mental workload assessment tools in the anaesthetic environment, in order to allow researchers and practitioners to understand the relative merits of the available tools.
Table 1.
Criteria for workload measurement methods9
| Criteria | Explanation |
| Simplicity and usability | Minimum equipment, non-intrusive/non interference with performance, acceptable to subjects |
| Availability | Timely and sufficiently rapid for use |
| Performance characteristics | Sensitivity to changes, selectively sensitive, insensitive to other task demands, inter-rater and intrarater reliability, adequate floor and ceiling effects, face validity |
| Diagnostic | Indicating the source of workload variation |
Methods
A systematic literature search was performed across five databases; Cochrane, EMBASE (via Ovid platform), MEDLINE (via Ovid platform), SCOPUS and Web of Science. The search strategy was piloted and tailored to the individual databases. A combination of Medical Subject Headings (MeSH) and free text terms was used to increase sensitivity for identification of potential studies. Search terms used ([workload* OR work load* OR over load* OR taskload* OR burnout* OR stress* OR anxiety* OR fatigue] AND ([anaesthesia* OR anaesthetist* OR anaesthesiology*]) were initially run individually and then combined in each database. References list of identified papers and previous reviews were checked for further data and citing articles were also sought from Google Scholar.
We included primary published research papers focusing on mental workload assessment tools used in anaesthesia and/or impact of workload on anaesthetists and patient safety up to February 2018. Studies in other languages were considered if an English translation version was available. We excluded reviews, descriptive articles, letters to the editor and opinions.
Data extraction
DA and TM both performed the search strategy and independently identified potential studies for inclusion at abstract stage. Data extraction was performed individually with disagreements resolved by the discussion and involvement of a third researcher (IM). Data extracted from individual studies included: sample size, study region, date of study, validity and reliability of workload measurement tool. Data are reported as presented in the studies. Due to heterogeneity of study results presentation, populations and tools used, no attempt has been made to pool data.
Results
Overview
Primary search produced 2388 articles. A total of 2313 studies were screened by title after removal of duplicates; 40 were eligible for abstract screening. Thirty-two studies were considered for full-text analysis and 2411–34 met the inclusion criteria with outcomes given with adequate data to assess study results. Most studies screened at full-text phase looked at effects of workload in general, not its measurement and therefore were excluded.35–42 Flow chart of study selection is detailed in figure 1.
Figure 1.

Flow diagram of included and excluded studies.
Characteristics of included studies are outlined in the online supplementary appendix 1.
bmjstel-2017-000263.supp1.pdf (235.1KB, pdf)
Types of mental workload measurement tools
Six mental workload measurement tools were identified (table 2). Rating scales of workload were used in 16 of these 24 studies. The Borg rating (6 to 20) scale was used in nine19–22 24–28 and NASA-TLX in five13 15 28 30 32. Gaba and Lee23 used a bespoke rating scale and Vredenburgh et al 33 used a survey instrument, both similar to NASA-TLX. Analysis of primary task performance (tasks required as part of anaesthesia care) was assessed in four studies,11 12 23 33 and performance of secondary tasks (arithmetic) was reported in three studies.23 29 34 Of the 24 studies, 11 assessed only one of the four concepts (scoring/task-oriented: 2, task performance: 5, response time capabilities: 2 and physiological changes: 2); 10 studies assessed scoring and response times, 2 scoring and physiology; 1 study assessed scoring, response time capabilities and physiology. Vigilance was assessed in 13 studies using either the vibrotactile device13–16 or response to a randomly illuminated light20–22 24–27 34 or alarm sound response latency.32 Physiological monitoring was reported in five papers17–19 22 28 from three studies. Pupil responses were reported in two papers from the same study17 19 and one from a different study.18
Table 2.
Tools used to measure mental workload in anaesthesia
| Tools | Measurement | Outcome |
| Borg workload | Self-reported workload score | 6 (no exertion), 20 (maximum exertion) |
| NASA-Task Load Index | Self-rating workload chart in six subscales mental, physical, temporal demand, frustration, effort and performance/success | Score ranges from 0 (minimal) to 10 (maximum possible) |
| Tasks | Response time | Primary task (response to task-related demands) Secondary task performance (measure of spare capacity) Absolute response time of mathematical addition task The rate of correct answers to the mathematical questions every 5 s |
| Vibrotactile device | Response time to a vibration on the upper arm | Absolute response time (ms) Response time (ms) above statistically derived ‘threshold’ |
| Eye-tracking device (EyeSeeCam) | Pupil diameter and eye movements | Absolute (mm) and change in pupil diameter Mean duration (seconds) of fixation episodes Amplitude (degrees) of saccades |
| Autonomic responses | Heart rate Respiratory rate |
Absolute and relative changes in HR Heart rate variability: time, frequency and entropy-derived metrics |
Type of tools used for each study are outlined in the online supplementary appendix 2.
bmjstel-2017-000263.supp2.pdf (193.7KB, pdf)
The Borg rating scale is widely used to assess workload in anaesthesia. It assess workload using a perceived exertion numerical scale from 6 (no exertion at all) to 20 (maximum exertion). Its use in anaesthesia settings such as clinical environments, simulated critical incidents and non-simulated critical incidents showed similar results. Essentially, during routine cases of anaesthesia, the Borg rating scale showed an increase in workload values during induction and emergency compared with maintenance. Similarly, comparatively high Borg rating values were observed during complex and moderate cases compared with simple cases. More experienced anaesthetists appeared to have spare mental capacity during standardised primary anaesthetic tasks as observed in their reporting of lower workload values from standardised incidents in comparison with less experienced anaesthetists. It could be argued the Borg scale is unidimensional and do not explicitly differentiate between physical and mental workload. Nevertheless, observed results from its use across included studies support the Borg rating scale to be an effective tool workload measurement tool.
The NASA-TLX workload measurement tool uses six categories: effort; mental demand; physical demand; temporal demand; frustration and performance to measure workload. Variations in NASA-TLX were comparable with the Borg rating scale and/or physiological monitoring tools,18 28 when both tools were used. When used with physiological measuring tools, significant positive correlation was observed between physiological outcome measures (heart rate, heart rate variability and pupil size) and NASA-TLX scores.28 For NASA-TLX domains across all included studies, higher workload scores were consistently observed in temporal, mental and physical domains not changed. However, there were inconsistent results for the frustration and performance domains across studies.
Tasks were used in two ways. First, accuracy of completion of a primary tasks (directly related to anaesthesia care) was used as a measure of workload. Alternatively, a secondary task was used to increase workload and/or assesses spare capacity. A positive correlation between subjective workload and primary workload density was reported.20 21
Workload assessment using secondary task measurements reported high levels of workload.
Alarm response latency (using either a light or vibrotactile device) was used to measure vigilance among anaesthetists. Response latency increased significantly at times of increased workload, whether during routine or crisis induced variation. The results of increasing workload with secondary tasks was inconsistent. Some studies reported a statistically significant increase in mean response time and others not; this may have been due to individuals’ performance variability (interindividual variation).
Physiological workload measurement tools uses physiological responses as a surrogate marker of mental workload including the assessment of subjects’ visual focus of attention. Heart rate alone had inconsistent relationship with workload with marked interindividual variability. More advanced metrics of autonomic function (derived from heart rate variability) showed better discriminative ability in one study.28 Pupil changes were inconsistently related to workload with marked interindividual variability.
Reliability
Two studies reported reliability of the tools’ measurement used. One study16 reported reliability (α=0.922) for the vibrotactile device. Another study27 reported reliability of the Borg scale which found to be moderate (concordance coefficient=0.55). Several studies20–22 25 26 reported moderate to good correlation between self-reported and observer workload rating using the Borg scale.
Discussion
Four techniques of measuring mental workload were found in our review: scoring, task performance, response time capabilities and physiological measures. The Borg rating scale measuring method was the most commonly used method and showed consistent association with expected variations in workload. Correlation between self-reported and observed rating was moderate to good.
Areas with increased workload such as the emergency department, intensive care unit and operating room are associated with a significantly higher rate of medical errors compared with other departments.43 While less well studied compared with other high-risk industries, mental workload among anaesthetists is presumably related to incidents and recovery from human error.44 Observed results support the concept that anaesthesia is similar to other high-risk industries such as aviation and nuclear power where human behaviour has positive and negative impacts on safety and performance. Workload is believed to be a key contributing factor for human error.3 NASA-TLX and Borg scale mental workload measurements are subjective cognitive workload measures that can be performed with a paper and a pencil and are easily available, readily accessible and only take a few minutes to complete.7 They have been widely studied and used in other settings.9 The NASA-TLX questionnaire has been extensively validated in the aviation and nuclear industries. It has been found to have diagnostic capability for subjective overload.45 It does not interfere with primary tasks and affords opportunity for operators’ individual perception of workload to be explored in depth. The Borg rating scale was the single most common measure used in the identified studies. It consistently demonstrates discriminant ability between expected contexts of varying workload: phases of anaesthesia, routine versus and non-routine-simulated scenarios.
The interpretation and ability of these scores to quantify performance is uncertain. Subjectivity is integral to the approach1 and it is unclear whether they are measuring mental workload or ‘stress’.46 All of the studies reported individual NASA-TLX subscales as well as the weighted summary score though formal analysis was less commonly carried out. Qualitatively, the temporal and mental domains were consistently associated with workload and physical domains not. Results were inconsistent for the frustration and performance domains, suggesting that NASA-TLX should be reported at domains level.
Vigilance (response latency) and physiological data are objective methods that require more technical involvement, considerable time for investigator and are moderately expensive. Physiological measurement methods are perceived as complex, intrusive and less likely to be part of daily routine use.47 With advances in technology, equipment is becoming much more portable, capable and acceptable.9 The vibrotactile device is unobtrusive and allows operators to move easily and can be freely used in different clinical practice settings without interfere with normal working practice. However, the definition of delay or threshold varies between studies which hampers interpretation.
Eye tracking provides objective surrogate measures of physiological responses (pupil diameter) and other behaviours. However, pupil diameter varies by individual, light intensity, time of day and caffeine, all of which are relevant to anaesthetists. Studies in aviation found that the influence of mental effort on eye movement measurement is highly reliant on specific task characteristics48 and therefore it is not suitable to use as a method to assess workload in aviation.
Heart rate appears to be inconsistent in its ability to discriminate workload. Advances in technology allow relatively straightforward and unobstrusive multimodal monitoring of autonomic physiology through chest harnesses. Johnstone et al 49 reported that this multivariable technology was demonstrated to be reliable and valid in a laboratory setting. However, in the workplace, interindividual variability, therapeutic drug use, caffeine and physical workload all potentially act as confounders. Changes within a low physical load situation may be reflective of mental workload, but this ideal may not exist in most scenarios where mental workload coincides with increased movement.
Study limitations
Presentation of results and the methods used to generate or infer differences in workload differed across the studies, making direct comparisons difficult. There were limited data comparing tools in the same setting.
Despite the attraction of objective measurement, some approaches directly interfere with clinical practice, making their widespread use questionable.
Self-reported measures have theoretical problems: subjectivity, lack of clarity of what is actually being measured and time delay. But on the evidence presented in this review, they do appear to have validity for measuring workload. They are sensitive to changes in workload in a variety of contexts and seem acceptable to users.
Conclusion
The measurement of mental workload in anaesthesia is an emerging field supporting patient and anaesthetist safety. Self-reported measures have the best evidence base to date.
Footnotes
Contributors: DSA and IKM made substantial contributions to conception and design of the study. DSA and TCM created search strategies and data extraction. DSA participated in drafting the article and IKM in revising it critically for important intellectual content. IKM gave final approval of the version to be submitted.
Funding: The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.
Competing interests: This work forms part of DA’s PhD thesis, which is supported by scholarship from the Libyan Ministry of Higher Education and university of Zawia. TCM was a PhD student supported by a grant from the Sir Jules Thorn Charitable Trust. IKM is a member of the NICE topic expert group for Quality Standards for hip fracture, Deputy Director of the National Institute of Academic Anaesthesia (NIAA) Research Council and holds grants from the National Institute for Health Research and the Association of Anaesthetists of Great Britain & Ireland and Royal College of Anaesthetists through the NIAA for trials in hip fracture.
Provenance and peer review: Not commissioned; externally peer reviewed.
References
- 1. Young MS, Stanton NA. Mental workload: theory, measurement, and application. Karwowski W, eds. International encyclopedia of ergonomics and human factors. 1. London: Taylor & Francis, 2001:507–9. [Google Scholar]
- 2. Wickens CD. Multiple resources and mental workload. Hum Factors 2008;50:449–55. 10.1518/001872008X288394 [DOI] [PubMed] [Google Scholar]
- 3. Glavin RJ. Drug errors: consequences, mechanisms, and avoidance. Br J Anaesth 2010;105:76–82. 10.1093/bja/aeq131 [DOI] [PubMed] [Google Scholar]
- 4. Lindfors PM, Nurmi KE, Meretoja OA, et al. On-call stress among Finnish anaesthetists. Anaesthesia 2006;61:856–66. 10.1111/j.1365-2044.2006.04749.x [DOI] [PubMed] [Google Scholar]
- 5. Nyssen AS, Hansez I, Baele P, et al. Occupational stress and burnout in anaesthesia. Br J Anaesth 2003;90:333–7. 10.1093/bja/aeg058 [DOI] [PubMed] [Google Scholar]
- 6. Bakker AB, Demerouti E. The Job demands‐resources model: state of the art. J Manag Psychol 2007;22:309–28. 10.1108/02683940710733115 [DOI] [Google Scholar]
- 7. Hart SG. Nasa-Task Load Index (NASA-TLX); 20 Years Later. Proc Hum Factors Ergon Soc Annu Meet 2006;50:904–8. 10.1177/154193120605000909 [DOI] [Google Scholar]
- 8. Hwang S-L, Yau Y-J, Lin Y-T, et al. Predicting work performance in nuclear power plants. Saf Sci 2008;46:1115–24. 10.1016/j.ssci.2007.06.005 [DOI] [Google Scholar]
- 9. Cain B. A review of the mental workload literature. 2007. http://www.dtic.mil/dtic/tr/fulltext/u2/a474193.pdf (accessed on 25 Jul 2016).
- 10. O’Donnell R, Eggemeier F. In: Boff K, Kaufman L, Thomas JP, eds. Workload assessment methodology handbook of perception and human performance. New York: Wiley, 1986. [Google Scholar]
- 11. Byrne AJ, Sellen AJ, Jones JG. Errors on anaesthetic record charts as a measure of anaesthetic performance during simulated critical incidents. Br J Anaesth 1998;80:58–62. 10.1093/bja/80.1.58 [DOI] [PubMed] [Google Scholar]
- 12. Byrne AJ, Sellen AJ, Jones JG, et al. Effect of videotape feedback on anaesthetists' performance while managing simulated anaesthetic crises: a multicentre study. Anaesthesia 2002;57:176–9. 10.1046/j.1365-2044.2002.02361.x [DOI] [PubMed] [Google Scholar]
- 13. Byrne AJ, Oliver M, Bodger O, et al. Novel method of measuring the mental workload of anaesthetists during clinical practice. Br J Anaesth 2010;105:767–71. 10.1093/bja/aeq240 [DOI] [PubMed] [Google Scholar]
- 14. Byrne AJ, Murphy A, McIntyre O, et al. The relationship between experience and mental workload in anaesthetic practice: an observational study. Anaesthesia 2013;68:1266–72. 10.1111/anae.12455 [DOI] [PubMed] [Google Scholar]
- 15. Byrne A, Tweed N, Halligan C. A pilot study of the mental workload of objective structured clinical examination examiners. Med Educ 2014;48:262–7. 10.1111/medu.12387 [DOI] [PubMed] [Google Scholar]
- 16. Davis DH, Oliver M, Byrne AJ. A novel method of measuring the mental workload of anaesthetists during simulated practice. Br J Anaesth 2009;103:665–9. 10.1093/bja/aep268 [DOI] [PubMed] [Google Scholar]
- 17. Schulz CM, Schneider E, Fritz L, et al. Eye tracking for assessment of workload: a pilot study in an anaesthesia simulator environment. Br J Anaesth 2011;106:44–50. 10.1093/bja/aeq307 [DOI] [PubMed] [Google Scholar]
- 18. Schulz CM, Skrzypczak M, Schneider E, et al. Assessment of subjective workload in an anaesthesia simulator environment: reliability and validity. Eur J Anaesthesiol 2011;28:502–5. 10.1097/EJA.0b013e328344836e [DOI] [PubMed] [Google Scholar]
- 19. Schulz CM, Schneider E, Kohlbecher S, et al. The influence of anaesthetists' experience on workload, performance and visual attention during simulated critical incidents. J Clin Monit Comput 2014;28:475–80. 10.1007/s10877-013-9443-8 [DOI] [PubMed] [Google Scholar]
- 20. Weinger MB, Herndon OW, Zornow MH, et al. An objective methodology for task analysis and workload assessment in anesthesia providers. Anesthesiology 1994;80:77–92. 10.1097/00000542-199401000-00015 [DOI] [PubMed] [Google Scholar]
- 21. Weinger MB, Herndon OW, Gaba DM. The effect of electronic record keeping and transesophageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia. Anesthesiology 1997;87:144–55. 10.1097/00000542-199707000-00019 [DOI] [PubMed] [Google Scholar]
- 22. Weinger MB, Reddy SB, Slagle JM. Multiple measures of anesthesia workload during teaching and nonteaching cases. Anesth Analg 2004;98:1419–25. 10.1213/01.ANE.0000106838.66901.D2 [DOI] [PubMed] [Google Scholar]
- 23. Gaba DM, Lee T. Measuring the workload of the anesthesiologist. Anesth Analg 1990;71:354–61. 10.1213/00000539-199010000-00006 [DOI] [PubMed] [Google Scholar]
- 24. Slagle JM, Weinger MB. Effects of intraoperative reading on vigilance and workload during anesthesia care in an academic medical center. Anesthesiology 2009;110:275–83. 10.1097/ALN.0b013e318194b1fc [DOI] [PubMed] [Google Scholar]
- 25. Slagle JM, Porterfield ES, Lorinc AN, et al. Prevalence of potentially distracting noncare activities and their effects on vigilance, workload, and nonroutine events during anesthesia care. Anesthesiology 2018;128:44–54. 10.1097/ALN.0000000000001915 [DOI] [PubMed] [Google Scholar]
- 26. Merry AF, Webster CS, Hannam J, et al. Multimodal system designed to reduce errors in recording and administration of drugs in anaesthesia: prospective randomised clinical evaluation. BMJ 2011;343:d5543–019. 10.1136/bmj.d5543 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Merry AF, Hannam JA, Webster CS, et al. Retesting the hypothesis of a clinical randomized controlled trial in a simulation environment to validate anesthesia simulation in error research (the VASER Study). Anesthesiology 2017;126:472–81. 10.1097/ALN.0000000000001514 [DOI] [PubMed] [Google Scholar]
- 28. Martin J, Schneider F, Kowalewskij A, et al. Linear and non-linear heart rate metrics for the assessment of anaesthetists' workload during general anaesthesia. Br J Anaesth 2016;117:767–74. 10.1093/bja/aew342 [DOI] [PubMed] [Google Scholar]
- 29. Sato H, Miyashita T, Kawakami H, et al. Influence of mental workload on the performance of anesthesiologists during induction of general anesthesia: a patient simulator study. Biomed Res Int 2016;2016:1–5. 10.1155/2016/1058750 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Prottengeier J, Petzoldt M, Jess N, et al. The effect of a standardised source of divided attention in airway management: A randomised, crossover, interventional manikin study. Eur J Anaesthesiol 2016;33:195–203. 10.1097/EJA.0000000000000315 [DOI] [PubMed] [Google Scholar]
- 31. Garden AL, Robinson BJ, Kappus LJ, et al. Fifteen-hour day shifts have little effect on the performance of taskwork by anaesthesia trainees during uncomplicated clinical simulation. Anaesth Intensive Care 2012;40:1028–34. [DOI] [PubMed] [Google Scholar]
- 32. de Man FR, Erwteman M, van Groeningen D, et al. The effect of audible alarms on anaesthesiologists' response times to adverse events in a simulated anaesthesia environment: a randomised trial. Anaesthesia 2014;69:598–603. 10.1111/anae.12640 [DOI] [PubMed] [Google Scholar]
- 33. Vredenburgh AG, Weinger MB, Williams KJ, et al. Developing a technique to measure anesthesiologists' real-time workload. Proceedings of the human factors and ergonomics society annual meeting. Los Angeles, CA:SAGE Publications Sage CA, 2000. [Google Scholar]
- 34. Cao CG, Weinger MB, Slagle J, et al. Differences in day and night shift clinical performance in anesthesiology. Hum Factors 2008;50:276–90. 10.1518/001872008X288303 [DOI] [PubMed] [Google Scholar]
- 35. Notcutt WG, Down MP. Anaesthetists and stress. Anaesthesia 1996;51:1072–3. 10.1111/j.1365-2044.1996.tb15010.x [DOI] [Google Scholar]
- 36. Peltola L, Mayer J, Cook J, et al. Increased anaesthetic workload associated with increased maternal age. Int J Obstet Anesth 2012;21:100–1. 10.1016/j.ijoa.2011.08.003 [DOI] [PubMed] [Google Scholar]
- 37. Chiron B, Michinov E, Olivier-Chiron E, et al. Job satisfaction, life satisfaction and burnout in French anaesthetists. J Health Psychol 2010;15:948–58. 10.1177/1359105309360072 [DOI] [PubMed] [Google Scholar]
- 38. Willoughby L, Morgan R. Neuroanaesthetists' experience of workload-related issues and long-duration cases. Anaesthesia 2005;60:151–4. 10.1111/j.1365-2044.2004.04061.x [DOI] [PubMed] [Google Scholar]
- 39. Carvalho B, Coghill J. Obstetric anaesthesia workload and time of day. Int J Obstet Anesth 2004;13:126–7. 10.1016/j.ijoa.2003.09.007 [DOI] [PubMed] [Google Scholar]
- 40. Hagau N, Pop RS. Prevalence of burnout in Romanian anaesthesia and intensive care physicians and associated factors. J Rom Anest Terap Int 2012;19:117–24. [Google Scholar]
- 41. Howard SK, Gaba DM, Smith BE, et al. Simulation study of rested versus sleep-deprived anesthesiologists. Anesthesiology 2003;98:1345–55. 10.1097/00000542-200306000-00008 [DOI] [PubMed] [Google Scholar]
- 42. Caldiroli D, Molteni F, Sommariva A, et al. Upper limb muscular activity and perceived workload during laryngoscopy: comparison of Glidescope(R) and Macintosh laryngoscopy in manikin: an observational study. Br J Anaesth 2014;112:563–9. 10.1093/bja/aet347 [DOI] [PubMed] [Google Scholar]
- 43. Cao A, Chintamani KK, Pandya AK, et al. NASA TLX: software for assessing subjective mental workload. Behav Res Methods 2009;41:113–7. 10.3758/BRM.41.1.113 [DOI] [PubMed] [Google Scholar]
- 44. Leedal JM, Smith AF. Methodological approaches to anaesthetists' workload in the operating theatre. Br J Anaesth 2005;94:702–9. 10.1093/bja/aei131 [DOI] [PubMed] [Google Scholar]
- 45. Soekkha HM. Aviation Safety: Human factors, system engineering, flight operations, economics, strategies, management: VSP, 1997. [Google Scholar]
- 46. Meshkati N. Heart rate variability and mental workload assessment. Adv Cogn Psychol 1988;52:101–15. 10.1016/S0166-4115(08)62384-5 [DOI] [Google Scholar]
- 47. Schulz CM, Schneider E, Fritz L, et al. Visual attention of anaesthetists during simulated critical incidents. Br J Anaesth 2011;106:807–13. 10.1093/bja/aer087 [DOI] [PubMed] [Google Scholar]
- 48. De Rivecourt M, Kuperus MN, Post WJ, et al. Cardiovascular and eye activity measures as indices for momentary changes in mental effort during simulated flight. Ergonomics 2008;51:1295–319. 10.1080/00140130802120267 [DOI] [PubMed] [Google Scholar]
- 49. Johnstone JA, Ford PA, Hughes G, et al. Bioharness(™) multivariable monitoring device: Part. II: reliability. J Sports Sci Med 2012;11:409–17. [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
bmjstel-2017-000263.supp1.pdf (235.1KB, pdf)
bmjstel-2017-000263.supp2.pdf (193.7KB, pdf)