Abstract
A patent foramen ovale (PFO) is an embryological remnant. Hypoxia in the setting of a PFO is generally attributed to pulmonary hypertension resulting in an increase in right atrial pressure and mixing of venous blood from the right atrium with blood in the left atrium resulting in a right-to-left interatrial shunt (RLIAS), thus deoxygenating it. We present a case of a 64-year-old male with a past medical history of coronary artery disease (CAD) who presented with two weeks of dyspnea on exertion and intermittent chest pressure. He was found to be hypoxic at 87% (normal >95%) with largely normal workup except for left anterior descending (LAD) stenosis, which was stented, and a PFO that was found on transesophageal echocardiogram with normal pulmonary artery pressure (PAP). This case of hypoxia in the setting of a PFO without pulmonary hypertension puts into question the pathophysiology of hypoxia in a PFO and RLIAS.
Keywords: left heart cath, right heart cath, transthoracic echocardiogram, echocardiogram, right to left atrioventricular shunt, hypoxia, patent foramen ovale
Introduction
A patent foramen ovale (PFO) is fairly common and occurs as an embryological remnant when the foramen ovale fails to close [1]. In the embryological stage, the foramen ovale creates a physiologic right-to-left interatrial shunt (RLIAS). Upon delivery, spontaneous ventilation results in an instant increase in pulmonary blood flow with an increased venous return to the left atrium increasing pressures on the foramen ovale, allowing for the fusion of the membranes which is composed of a septum primum and secundum. A deficiency in portions of this septum results in a PFO.
Although generally asymptomatic, PFOs have been associated with a variety of medical disorders including cerebrovascular accidents, transient ischemic attacks, migraines, decompression syndrome, and systemic desaturation. Initially, a PFO provides left-to-right interatrial shunting since the left atrial pressure is greater than that of the right atrium. Eventually, some patients may develop Eisenmenger syndrome resulting in RLIAS allowing for deoxygenated blood returning to the right atrium to shunt through the left atrium and is ejected into the systemic circulation. Cases like ours highlight the occurrence of hypoxia and RLIAS in a patient without pulmonary hypertension, suggesting an alternative mechanism of hypoxia in RLIAS.
The five main mechanisms of hypoxia are hypoventilation, ventilation-perfusion mismatch, right-to-left shunts (may be anatomic or physiologic), diffusion limitations, and reduced inspired oxygen tension [2]. Hypoventilation may occur in the setting of central nervous system (CNS) depression, obesity hypoventilation, impaired neuronal conduction, muscular weakness (such as in myasthenia gravis or severe hypothyroidism), or poor chest wall elasticity. CNS depression may occur in the setting of drug overdose or structural CNS lesions. Poor chest wall elasticity may be seen in conditions such as kyphoscoliosis and flail chest. Ventilation-perfusion (V/Q) mismatch generally occurs when there is an imbalance of the pulmonary blood supply and ventilation. Hypoxia that is due to V/Q mismatch generally improves with supplemental oxygen. Conditions that cause this include obstructive lung disease, interstitial disease, emphysema, heart failure, or pulmonary vascular disease such as pulmonary emboli. Right-to-left shunt is discussed above and occurs when blood travels from the right to left atrium without being oxygenated, causing severe V/Q mismatch. Anatomic shunts may include atrial septal defects, PFOs, pulmonary arteriovenous malformations, and hepatopulmonary syndrome. Physiologic shunts include atelectasis and alveolar filling diseases, such as with red blood cells, white blood cells, fluid, protein, or other tissue cells. Diffusion limitation occurs when the alveoli are inflamed or fibrose. Reduced oxygen-inspired tension occurs in areas of reduced oxygen saturation, such as at elevated altitudes. In the setting of hypoxia, there is insufficient oxygen for cells to meet their metabolic demands.
Hypoxia is diagnosed by pulse oximetry and generally presents with dyspnea on exertion. The past medical history is an important component in determining the cause and should include the history of pulmonary or cardiac disease. A thorough history also includes current medications, focusing on opioids and benzodiazepines, as well as illicit drugs. Any active symptoms should be addressed. Conditions that cause impaired neuronal conduction such as amyotrophic lateral sclerosis, Guillain-Barre syndrome, cervical spine injury, phrenic nerve paralysis can all result in hypoxia and should be examined [2]. A patient's weight could be an indicator of possible obesity hypoventilation syndrome or obstructive sleep apnea. Physical exam should pay special attention to the chest wall, examining for kyphosis or flail chest, and pulmonary exam, which may demonstrate crackles or wheezing. Laboratory studies should include arterial blood gasses, comprehensive blood count, comprehensive metabolic panel, and thyroid function tests. A chest x-ray and echocardiogram should be obtained. An echocardiogram can show an atrial septal defect or PFO as well as assess pulmonary artery pressure to determine the presence of pulmonary hypertension. A V/Q scan or computed tomography angiography (CTA) chest can also be obtained if there is a concern for pulmonary embolism.
Case presentation
A 64-year-old male with a past medical history of coronary artery disease (CAD) presented to our institution with progressive dyspnea on exertion and intermittent chest pressure of two weeks duration. His medical history was notable for CAD with stent placement to the left anterior descending artery (LAD) six months prior to presentation and obstructive sleep apnea. Social history was notable for his job in coal mining for two years. He was a non-smoker.
On admission, his vital signs were normal except for his oxygen saturation, which was 87% on room air. Physical examination did not reveal any abnormalities. Laboratory investigations were unremarkable with normal hemoglobin and hematocrit levels. A computer tomography angiography (CTA) of the chest did not reveal evidence of pulmonary embolism or other abnormalities. Ventilation-perfusion scan showed normal perfusion. Pulmonary function tests were normal. Right and left heart catheterization revealed critical proximal LAD stenosis, normal cardiac output, and index by thermodilution. Findings are seen in Table 1 and revealed normal pulmonary capillary wedge pressure (PCWP), left ventricular end-diastolic pressure (LVEDP), and pulmonary artery pressure (PAP). A drug-eluting stent (DES) was placed in the LAD. A transthoracic and transesophageal echocardiogram with agitated saline showed evidence of a PFO with right-to-left shunting by evidence of color flow Doppler (Figure 1) with an enlarged right atrium and right ventricle.
Table 1. Measured pressures during right heart catheterization .
| Measured value | Normal range | |
| Pulmonary capillary wedge pressure (PCWP) | 12 mmHg | 4-12 mmHg |
| Left ventricular end-diastolic pressure (LVEDP) | 12 mmHg | 4- 12 mmHg |
| Pulmonary artery systolic pressure | 32 mmHg | 8-25 mmHg |
| Pulmonary artery diastolic pressure | 15 mmHg | 8-15 mmHg |
| Mean pulmonary artery pressure | 22 mmHg | < 20 mmHg (elevated when >25 mmHg at rest) |
| Right atrial pressure | 10 mmHg | 2-6 mmHg |
| Right ventricle systolic pressure | 13 mmHg | 20-30 mmHg |
| Right ventricle diastolic pressure | 10 mmHg | 3-7 mmHg |
Figure 1. Transesophageal Echocardiogram (TEE) with yellow circle showing the RLIAS with evidence of PFO .
RLIAS: right-to-left interatrial shunt; PFO: patent foramen ovale
The patient’s hypoxia was attributed to RLIAS in the absence of other causative factors. He underwent successful closure of the PFO with subsequent resolution of hypoxia.
Discussion
Our workup was negative except for a PFO and RLIAS. RLIAS in PFOs generally occurs when chronic left-to-right shunting results in pulmonary hypertension increasing right atrial pressures until they rise above left atrial pressures, a condition called Eisenmenger syndrome. Since our patient did not have pulmonary hypertension, this put into question the mechanism of RLIAS in his PFO. One proposed theory of RLIAS in patients with PFO without evidence of pulmonary hypertension is the presence of a remnant eustachian valve (EV). One study found that 70% of patients with PFO continue to have an EV, which is a remnant of the embryonic right valve of the sinus venosus. In fetal circulation, the EV is physiologic and directs oxygenated blood from the inferior vena cava across the PFO and into the systemic circulation. If present in an adult, this may allow for preferential blood flow towards the PFO and resultant RLIAS [3]. RLIAS may also occur in the setting of certain anatomical abnormalities in the absence of pulmonary hypertension such as pneumonectomy [4], diaphragm paralysis, kyphoscoliosis, the elevation of the right hemidiaphragm [5], dilation of the ascending aorta [5], and obstructive sleep apnea. Platypnea-orthodeoxia can also occur in patients with PFO and presents as dyspnea and hypoxia that occur when patients change from a supine to an upright position [6,7]. This is due to the physiological increase in right atrial pressure in the setting of a change in position or Valsalva maneuver, causing a reversal in blood flow and a transient RLIAS ultimately resulting in hypoxia.
PFOs are diagnosed using an echocardiogram with bubbles or with contrast. In a bubble study, agitated saline is first injected into the body during the study. The study is positive when contrast is noted to be in the left atrium during early ventricular systole. A transesophageal echocardiogram (TEE) is then performed to confirm the PFO as well as to characterize its anatomy and dimensions, in order to assess its suitability for device closure.
Indications for PFO closure include cryptogenic strokes with a high risk of paradoxical embolism (RoPE) scores, decompression syndrome, platypnea-orthodeoxia syndrome, and shunt-induced cyanosis. In patients with a PFO who present with a cryptogenic stroke, the RoPE score is a convenient tool for estimating the probability that a stroke is associated with a PFO, rather than it being an incidental finding. A score greater than 7 indicates a high probability of association. One important contraindication of PFO closure is irreversible pulmonary hypertension due to the risk of decompensation of the right ventricular function and a resultant drop in cardiac output after closure [8]. Generally, percutaneous closure is implemented unless other defects are present that require intervention. It is generally safe, but like all procedures has risks including arrhythmias, infection, device migration, or hemorrhage in the setting of a traumatic puncture of the coronary vessels. One study found in patients with a PFO who have normal right-sided pressures, percutaneous PFO closure may result in marked improvement of their symptoms [9].
Conclusions
PFOs are common in the general population and may result in marked hypoxia in the setting of RLIAS. The pathophysiology of RLIAS in PFOs generally occurs in the setting of pulmonary hypertension and increased right atrial pressure in a condition called Eisenmenger syndrome. Our patient with a PFO and a normal pulmonary artery pressure (PAP) with a negative workup for other causes of hypoxia suggests alternative pathophysiology that is less well understood. Normal pulmonary pressures in these patients, therefore, should not dissuade further intervention with percutaneous PFO closure in patients with hypoxia since closure has shown to improve both hypoxia and quality of life.
The content published in Cureus is the result of clinical experience and/or research by independent individuals or organizations. Cureus is not responsible for the scientific accuracy or reliability of data or conclusions published herein. All content published within Cureus is intended only for educational, research and reference purposes. Additionally, articles published within Cureus should not be deemed a suitable substitute for the advice of a qualified health care professional. Do not disregard or avoid professional medical advice due to content published within Cureus.
This research was supported (in whole or in part) by HCA (Hospital Corporation of America) Healthcare and/or an HCA Healthcare-affiliated entity. The views expressed in this publication represent those of the author(s) and do not necessarily represent the official views of HCA Healthcare or any of its affiliated entities.
Human Ethics
Consent was obtained or waived by all participants in this study
References
- 1.Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea. Shanoudy H, Soliman A, Raggi P, Liu JW, Russell DC, Jarmukli NF. https://doi.org/10.1378/chest.113.1.91. Chest. 1998;113:91–96. doi: 10.1378/chest.113.1.91. [DOI] [PubMed] [Google Scholar]
- 2.Theodore AC. UpToDate. Waltham, Massachusetts: UpToDate; 2022. Measures of oxygenation and mechanisms of hypoxemia. [Google Scholar]
- 3.Persisting eustachian valve in adults: relation to patent foramen ovale and cerebrovascular events. Schuchlenz HW, Saurer G, Weihs W, Rehak P. J Am Soc Echocardiogr. 2004;17:231–233. doi: 10.1016/j.echo.2003.12.003. [DOI] [PubMed] [Google Scholar]
- 4.Patent foramen ovale and platypnea after pneumonectomy (Article in German) Buss J, Grimm V, Huck K, Jaschke W, Heene DL. Dtsch Med Wochenschr. 1992;117:1874–1880. doi: 10.1055/s-2008-1062523. [DOI] [PubMed] [Google Scholar]
- 5.Right hemidiaphragmatic elevation with a right-to-left interatrial shunt through a patent foramen ovale: a case report and literature review. Ghamande S, Ramsey R, Rhodes JF, Stoller JK. Chest. 2001;120:2094–2096. doi: 10.1378/chest.120.6.2094. [DOI] [PubMed] [Google Scholar]
- 6.Orthodeoxia-platypnea due to intracardiac shunting--relief with transcatheter double umbrella closure. Landzberg MJ, Sloss LJ, Faherty CE, et al. Cathet Cardiovasc Diagn. 1995;36:247–250. doi: 10.1002/ccd.1810360312. [DOI] [PubMed] [Google Scholar]
- 7.Platypnea-orthodeoxia: an unusual indication for surgical closure of a patent foramen ovale. Murray KD, Kalanges LK, Weiland JE, Binkley PF, Howanitz EP, Galbraith TA, Myerowitz PD. J Card Surg. 1991;6:62–67. doi: 10.1111/j.1540-8191.1991.tb00565.x. [DOI] [PubMed] [Google Scholar]
- 8.To close or not to close: contemporary indications for patent foramen ovale closure. Zier LS, Sievert H, Mahadevan VS. https://doi.org. Expert Rev Cardiovasc Ther. 2016;14:1235–1244. doi: 10.1080/14779072.2016.1224178. [DOI] [PubMed] [Google Scholar]
- 9.Patent foramen ovale and hypoxemia. Mojadidi MK, Ruiz JC, Chertoff J, et al. https://doi.org/ Cardiol Rev. 2019;27:34–40. doi: 10.1097/CRD.0000000000000205. [DOI] [PubMed] [Google Scholar]