Skip to main content
Case Reports in Gastroenterology logoLink to Case Reports in Gastroenterology
. 2022 Mar 25;16(1):135–139. doi: 10.1159/000522252

Endoscopic Removal of a Denture Lining Material Stuck in the Duodenum

Makoto Eizuka a,b,*, Yosuke Toya a, Manami Miura b, Hiroshi Takahashi b, Takayuki Matsumoto a
PMCID: PMC9035964  PMID: 35528776

Abstract

A 52-year-old woman visited our hospital with a complaint of upper abdominal pain. Abdominal computed tomography did not show any lesion responsible for the pain. However, esophagogastroduodenoscopy identified a pale, pink-colored, U-shaped foreign body stuck in the descending part of the duodenum. We removed it by gently pulling forward in an antegrade fashion with the use of a snare. Duodenography after the removal did not show any sign of leakage to the abdominal cavity or to the retroperitoneum. The foreign body was found to be a denture lining material equipped 3 days previously.

Keywords: Foreign bodies in the gastrointestinal tract, Denture lining material, Endoscopic removal

Introduction

Foreign bodies in the gastrointestinal tract may cause bleeding, mucosal ulcerations, and perforations, all of which may require urgent treatment [1, 2, 3]. There are various types of foreign body in the gastrointestinal tract such as press-through-pack medications, food, bones, and metals [4, 5, 6, 7].

They often remain in the gastrointestinal tract, predominantly in the esophagus, followed by the stomach. However, there are only a few reports of foreign bodies in the duodenum [4, 5, 6, 7]. Furthermore, a certain proportion of foreign bodies in the gastrointestinal tract cannot be removed endoscopically because of their size, hardness, and sharpness [2, 5]. We herein report a case of a denture lining material stuck in the descending part of the duodenum, which could be removed endoscopically without any complication.

Case Presentation

A 52-year-old woman visited our hospital with a complaint of upper abdominal pain. Physical examination revealed tenderness in the epigastric region without rebound tenderness. Laboratory data showed no abnormalities except for mild anemia. Abdominal computed tomography (CT) did not show any lesion responsible for the pain (Fig. 1). However, esophagogastroduodenoscopy identified a pale, and pink-colored, foreign body stuck in the descending part of the duodenum (Fig. 2a). Because CT did not show any sign suggestive of perforation, we decided to remove it endoscopically. We first grabbed the center of the foreign body by an electrocautery snare (SD-6L-1, Olympus, Tokyo, Japan) and then gently pulled the snare forward in an antegrade fashion (Fig. 2b). We took the foreign body out of the mouth by grabbing the tip with the snare. After the removal, we performed duodenography with the use of iodined contrast material, which did not show any sign of leakage to the abdominal cavity or to the retroperitoneum (Fig. 3). The removed foreign body was a 70 mm-sized, pale, and pink hard resin, which was bent like a hairpin (Fig. 4).

Fig. 1.

Fig. 1

Abdominal CT did not show any lesion responsible for the pain.

Fig. 2.

Fig. 2

a EGD identified a pale, pink-colored, U-shaped foreign body stuck in the duodenum. b We grabbed the center of the foreign body by electrocautery snare and gently pulled out. EGD, esophagogastroduodenoscopy.

Fig. 3.

Fig. 3

After removal, we added duodenography, which did not show any sign of leakage to the abdominal cavity or to the retroperitoneum.

Fig. 4.

Fig. 4

Foreign body was a 70 mm-sized, pale, and pink hard resin that was bent like a hairpin.

A detailed checkup of her illness revealed that she had been visiting a dentist and that she ingested something hard a few days before her abdominal pain occurred. We thus consulted the dentist, who testified that the foreign body was a denture lining material.

Discussion

It has been well known that foreign bodies in the gastrointestinal tract can cause serious complications. They often are retained in the esophagus and may be endoscopically removable, according to their hardness and sharpness [2, 5].

In our case, the denture lining material was found as a foreign body in the duodenum. The material is routinely used to fill the gap when the denture does not fit the gingiva [8]. It is made of a fluorine-based methacrylic acid-based monomer, and the clay-like composition transforms to a resin after approximately 5 min at room temperature [9, 10].

Dentures and dental instruments are often found as foreign bodies in the gastrointestinal tract [4, 5, 6, 7]. It has been reported that the ingestion of dentures and dental instruments is triggered by dental procedures, accidental swallowing, and tracheal intubation [11]. Among dentures and dental instruments, crowns and bridges are the most common foreign bodies. Those foreign bodies often remain in the esophagus and the stomach, and they are found as radiopaque substances [11].

Saltiel et al. [6] reported that radiographic visibility is associated with the high success rate of endoscopic removal for foreign bodies. In our case, however, CT failed to identify the foreign body, probably because of radiolucency of the material. Our case suggests that it may be important to confirm a history of the ingestion of dentures and dental instruments to diagnose gastrointestinal foreign bodies even if CT fails to indicate signs of foreign bodies.

Intestinal perforation due to gastrointestinal foreign body occurs predominantly in the terminal ileum and in the sigmoid colon [12]. The small intestine is thought to be at a higher risk of perforation induced by sharp and hard foreign bodies than the remaining gastrointestinal tract because of its narrow lumen and thin wall [13]. With regards to dental materials, Mizuno et al. [11] reported that immediate intervention and appropriate selection of devices, such as forceps, snare, and nets, are essential for the removal. In our case, we applied a snare for the removal of stuck denture lining material without adverse event. While the foreign body was apparently penetrating the duodenal wall, there was not any clinical, endoscopic, or radiographic sign of duodenal perforation.

The uneventful clinical course may partly be explained by the anatomical specificity of the duodenum, which is surrounded by firm retroperitoneum. Time duration for a few days from the ingestion until removal of the material may also account for the less severe retroperitoneal inflammation.

In conclusion, we encountered a case of a denture lining material stuck in the duodenum, which could be removed endoscopically without adverse events. Foreign bodies in the duodenum may be candidates for endoscopic removal even if they are stuck in the duodenal lumen.

Statement of Ethics

As this paper is a single case report, it has not been approved by the Ethics Committee. Written informed consent was obtained from the patient for the publication of this case report and any accompanying images. Research complies with the guidelines for human studies and was conducted ethically in accordance with the World Medical Association Declaration of Helsinki. This study protocol was reviewed, and the need for approval was waived by the IRB at Iwate Medical University.

Conflict of Interest Statement

The authors declare that they have no conflicts of interests.

Funding Sources

The authors have no funding sources to disclose.

Author Contributions

E.M. and T.Y. contributed to writing this manuscript. M.M. and T.H. were involved in the patient's treatment. T.M. contributed to supervising the writing of the manuscript. All the authors contributed to the diagnosis, the treatment, and the clinical management of the patient. All the authors read and approved the final manuscript.

Data Availability Statement

The authors confirm that the data supporting the findings of this study are available within the article.

References

  • 1.Webb WA. Management of foreign bodies of the upper gastrointestinal tract. Gastroenterology. 1988;94:204–16. doi: 10.1016/0016-5085(88)90632-4. [DOI] [PubMed] [Google Scholar]
  • 2.Cha MH, Sandooja R, Khalid S, Lao N, Lim J, Razik R. Complication rates in emergent endoscopy for foreign bodies under different sedation modalities: A large single-center retrospective review. World J Gastrointest Endosc. 2021;13((2)):45–55. doi: 10.4253/wjge.v13.i2.45. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Geraci G, Sciume C, Di Carlo G, Picciurro A, Modica G. Retrospective analysis of management of ingested foreign bodies and food impactions in emergency endoscopic setting in adults. BMC Emerg Med. 2016;16:42. doi: 10.1186/s12873-016-0104-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Wang X, Su S, Chen Y, Wang Z, Li Y, Hou J, et al. The removal of foreign body ingestion in the upper gastrointestinal tract: a retrospective study of 1,182 adult cases. Ann Transl Med. 2021;9:502. doi: 10.21037/atm-21-829. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Limpias Kamiya KJ, Hosoe N, Takabayashi K, Hayashi Y, Sun X, Miyanaga R, et al. Endoscopic removal of foreign bodies: a retrospective study in Japan. World J Gastrointest Endosc. 2020;12:33–41. doi: 10.4253/wjge.v12.i1.33. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Saltiel J, Molinsky R, Lebwohl B. Predictors of outcomes in endoscopies for foreign body ingestion: a cross-sectional study. Dig Dis Sci. 2020;65:2637–43. doi: 10.1007/s10620-019-06033-3. [DOI] [PubMed] [Google Scholar]
  • 7.Hong KH, Kim YJ, Kim JH, Chun SW, Kim HM, Cho JH. Risk factors for complications associated with upper gastrointestinal foreign bodies. World J Gastroenterol. 2015;21:8125–31. doi: 10.3748/wjg.v21.i26.8125. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Mack PJ. Denture soft lining materials: clinical indications. Aust Dent J. 1989;34:454–8. doi: 10.1111/j.1834-7819.1989.tb00704.x. [DOI] [PubMed] [Google Scholar]
  • 9.Kasuga Y, Takahashi H, Akiba N, Minakuchi S, Matsushita N, Hishimoto M. Basic evaluation on physical properties of experimental fluorinated soft lining materials. Dent Mater J. 2011;30:45–51. doi: 10.4012/dmj.2010-084. [DOI] [PubMed] [Google Scholar]
  • 10.Hayakawa I, Akiba N, Keh E, Kasuga Y. Physical properties of a new denture lining material containing a fluoroalkyl methacrylate polymer. J Prosthet Dent. 2006;96:53–8. doi: 10.1016/j.prosdent.2006.05.012. [DOI] [PubMed] [Google Scholar]
  • 11.Mizuno KI, Takahashi K, Tominaga K, Nishigaki Y, Sato H, Ikarashi S, et al. Endoscopic removal of ingested dentures and dental instruments: a retrospective analysis. Gastroenterol Res Pract. 2016;2016:3537147. doi: 10.1155/2016/3537147. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Goh BK, Chow PK, Quah HM, Ong HS, Eu KW, Ooi LL, et al. Perforation of the gastrointestinal tract secondary to ingestion of foreign bodies. World J Surg. 2006;30:372–7. doi: 10.1007/s00268-005-0490-2. [DOI] [PubMed] [Google Scholar]
  • 13.Ma T, Zheng W, An B, Xia Y, Chen G. Small bowel perforation secondary to foreign body ingestion mimicking acute appendicitis: Case report. Medicine. 2019;98:e16489. doi: 10.1097/MD.0000000000016489. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The authors confirm that the data supporting the findings of this study are available within the article.


Articles from Case Reports in Gastroenterology are provided here courtesy of Karger Publishers

RESOURCES