Intravenous contrast medium extravasation: systematic review and updated ESUR Contrast Media Safety Committee Guidelines

Giles Roditi 1,#, Nadir Khan 1,#, Aart J van der Molen 2, Marie-France Bellin 3, Michele Bertolotto 4, Torkel Brismar 5, Jean-Michel Correas 6, Ilona A Dekkers 2, Remy W F Geenen 7, Gertraud Heinz-Peer 8, Andreas H Mahnken 9, Carlo C Quattrocchi 10, Alexander Radbruch 11, Peter Reimer 12, Laura Romanini 13, Fulvio Stacul 14, Henrik S Thomsen 15, Olivier Clément 16,
PMCID: PMC9038843  PMID: 35175378

Abstract

Need for a review

Guidelines for management and prevention of contrast media extravasation have not been updated recently. In view of emerging research and changing working practices, this review aims to inform update on the current guidelines.

Areas covered

In this paper, we review the literature pertaining to the pathophysiology, diagnosis, risk factors and treatments of contrast media extravasation. A suggested protocol and guidelines are recommended based upon the available literature.

Key Points

• Risk of extravasation is dependent on scanning technique and patient risk factors.

• Diagnosis is mostly clinical, and outcomes are mostly favourable.

• Referral to surgery should be based on clinical severity rather than extravasated volume.

Supplementary Information

The online version contains supplementary material available at 10.1007/s00330-021-08433-4.

Keywords: Contrast media, Extravasation of diagnostic and therapeutic materials, Risk factors, Prevention and treatments

Introduction

Contrast media extravasation (CMEX) is a complication where there is leakage of intravenously administered contrast agents (either iodine or gadolinium-based), into the surrounding soft-tissues [1]. This can vary in severity from minor discomfort to compartment syndrome, skin ulceration and necrosis. A recent observational study of 142,651 participants undergoing CT scans showed a CMEX incidence of 0.23% [2] whilst a systematic review by Behzadi et al. accounting for 17 studies in 1,104,872 patients found CMEX rates of 0.2% [3]. Rates of serious CMEX seem much lower, only described in case reports and case series [47] although this probably reflects under-reporting.

CMEXs are thought to be one of the most frequent adverse events in radiology but are much less studied than others such as contrast-associated acute kidney injury [810]. Whilst CMEX does not usually lead to significant morbidity, the rare, serious complications of compartment syndrome, skin ulceration and tissue necrosis are important to recognise [46]. Furthermore, even what may be clinically regarded as minor CMEX will be perceived as important by the patient and contribute to feelings of dissatisfaction at a stressful time since “something has gone wrong” with their care.

Previous guidelines around CMEX from the Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) published in 2002 related to older contrast injection protocols [1]. Since then, several prospective studies investigating CMEX risk factors and management as well as systematic reviews have been published [2, 3, 1113]. In this paper, we aim to inform update of the CMSC guidelines by performing a systematic review and provide recommendations.

Methodology

Authors prepared seven clinical questions in Patient–Intervention–Comparison–Outcome (PICO) format [14]. A systematic literature search of PubMed and Scopus from 1 January 1990 through to 6 February 2021 with MeSH terms as described in the search strategy (Appendix 1) was performed by a radiology trainee (N.K.) with previous meta-analysis experience and a radiology consultant (G.R.). Abstracts were reviewed for relevance, references scrutinised and cross-referenced. Only articles in English pertaining to intravenous CMEX in context of CT and MRI were considered. References from previous CMSC guidelines were included. CMEXs associated with contrast-enhanced ultrasound were excluded as no cases have been reported in the literature [1517]. Studies assessing intra-arterial CMEX and non-contrast media-based extravasation were also excluded (Fig. 1 flow-chart of article selection and final number of articles).

Fig. 1.

Fig. 1

Search and selection procedures

Risk of bias of each study included was graded according to National Institutes of Health (NIH) study quality assessment tools. The strength of recommendation of different risk factors, diagnosis, detection and management of CMEX were graded according to OCEBM Levels of Evidence Working Group “The Oxford 2011 Level of Evidence” (Appendices 2 and 3). Characteristics, risk of bias and levels of evidence for each included study are outlined in Appendix 4.

Studies were synthesised and summarised narratively.

What are the pathophysiologic mechanisms of CMEX?

Three main processes underpin the mechanisms of CMEX [18]. The first model describes fluid escaping into perivascular tissue through extraluminal dislocation or break of the catheter tip. The second model describes a leak through the puncture site of a correctly placed cannula leading to extravasation. The third model envisages shear stresses and total pressure from the jet at the vessel wall directly leading to vessel disruption and extravasation [19].

The degree to which tissue damage occurs due to CMEX is dependent on the CM used (osmolality, cytotoxicity and extravasated volume) plus location of the cannula; more damage occurs with involvement of tight sub-fascial compartments compared to looser subcutaneous layers [20]. An acute inflammatory response which peaks up to 48 h after injection can be followed by several weeks of chronic inflammation [21]. However, the majority resolve in 2–4 days with resorption of CM extravasate thought to be primarily by the lymphatic system [13].

Consequently, much research has been based on preventing cannula dislodgement and exploring the impact of variables that increase risk of leakage from the puncture site.

How to detect extravasation?

With CMEX contrast escapes and infiltrates the interstitium during injection. This is mostly a clinical diagnosis and routine use of imaging is not indicated for its detection.

Non-physicians are usually first responders to CMEX, i.e. radiology technicians/radiographers and healthcare support workers. Hence, it is recommended that imaging departments follow a protocol which allows identification of at-risk patients, easy detection of CMEX, awareness of monitoring needs and effective management of extravasation by a wide range of staff [22]. As an excerpt from multiple publications, the following algorithm is proposed (Table 1). Outpatients with extravasation should be kept under observation in the department until a physician is satisfied that signs and symptoms are resolving such that intervention will not be needed and the patient allowed home.

Table 1.

Recognition and diagnosis of contrast media extravasation

Grade of recommendation*
Instruct the patient to report any pain or swelling, during or after injection D
Observe for signs of extravasation directly both during and following injection plus, and directly palpate the cannula insertion site C
During Contrast media infusion observe for any alerts on the contrast injection system and observe the patient for signs of distress. Observe monitoring scans for expected contrast arrival and completed scans for enhancement B
Mark out affected area when contrast media extravasation occurs B
Assess severity of any extravasation:
  Mild Minor erythema or swelling, no skin changes
  Moderate Skin blistering, progressive oedema and/or ulceration. These will require close monitoring and physician assessment is advised to assess for any neurovascular compromise by checking peripheral pulse and sensation distal in the affected limb
  Severe Any neurovascular compromise, signs of tissue necrosis or compartment syndrome. This would require urgent surgical attention e.g. emergency fasciotomy

*Grade of recommendation (see Appendix 2)

We summarise three main ways of detecting CMEX in Table 2.

Table 2.

 Detection of contrast media extravasation

1. Direct Patient Observation: Technician/radiographer in room or video monitoring as well as self-reporting by the patient. Observation of monitoring scans for expected contrast arrival and completed scans for enhancement.

2. Pressure Monitoring: Power-injectors for contrast media (CM) administration now have pressure monitoring systems with graphic displays and flow profile previews which can automatically or semi-automatically stop the CM injection if increased resistance or faults within the system are encountered. One of the promoted benefits of this technology is CM extravasation prevention/minimisation although no published studies have specifically explored their impact to date.

3. Extravasation detection accessories: Some vendors have developed sensors to detect CM extravasation amongst other capabilities.

Many vendors have developed Extravasation Detection Accessories (EDA) which are sensors that allow detection and interruption of automated injection in the event of an extravasation. Dykes et al. demonstrated the use of EDA resulted in smaller volumes of CMEX when they occurred compared to when no EDA was utilised (1,085 CMEX events in 454,497 CT exams across 58 radiology practices) [23]. However, incidence of CMEX did not change and importantly some large volume extravasations still occurred with 28 patients suffering 50–99 ml of CMEX and 4 patients experiencing > 100 ml of extravasate (unlike studies by Powell et al. and Birnbaum et al.). However, with multiple centres, it was difficult to compare the performance of different EDAs against each other since the centres used different EDAs (types not specified) [23].

One quality improvement project and three case-series have investigated EDA use; each assessed a different device [2427]. Two studies only published preliminary results and did not specify sensitivity or specificity [28, 29]. These devices rather than fully preventing extravasation are designed to detect it early and so prevent a mild extravasation from becoming moderate or even severe. A summary of the clinically tested EDA devices is provided in Appendix 5.

Is documentation of extravasation needed?

Proper documentation of CMEX is crucial [12]; at the patient level, this allows early recognition of deterioration and aids interpretation across a broad range of healthcare staff. More broadly, documentation at an institutional level allows auditing which can improve local working practices. Dykes et al. showed that the rates of observed CMEX reduced as a result of multi-institution audit; however, they did not impact the volume of extravasate when extravasation did occur [23].

With severe extravasations, imaging documentation may be helpful [30]. Plain radiographs with 2 orthogonal views, 2-plane CT topogram or indeed cross-sectional images with the CT or MRI scanner before removing the patient from scanner table are recommended to assess for compartmentalisation (subfascial vs subcutaneous) and extent of extravasate [21, 31].

What are the risk factors for extravasation?

Technique related

Peripheral IV cannula type, size and location

Six studies evaluated the influence of the physical properties of cannulae; none were prospective randomised trials. A pseudo-randomised trial compared between a fenestrated 20G and a non-fenestrated 18G cannula which showed no effect on CMEX rates or volume [32]. Furthermore, retrospective cohort studies have shown that extravasation rates were higher with 22G compared to 20G and 18G cannulas, but no significant difference between 18 and 20G cannulas [3335]. In addition, these studies have reported no difference in extravasate volume between the use of different cannula sizes. In a paediatric prospective cohort study, there was no effect of cannula size on CMEX [36]. Location of the peripheral cannula was an important risk factor in three studies with higher rates of extravasation when placed in a vein in the dorsum of hand compared to an antecubital fossa vein. However, higher volume of extravasate was observed with injections in antecubital fossa versus hand veins despite the higher incidence at the hand/wrist, likely related to use of higher flow rates and delayed recognition of CMEX at the antecubital fossa. Overall, injection sites in the lower limbs and small distal veins are less optimal.

CVCs, PICCs and power injectable ports

Central venous catheters (CVC—tunnelled or non-tunnelled), totally implantable vascular access devices, haemodialysis catheters and peripherally inserted central catheters (PICCs) are increasingly used for patients in critical care, on chemotherapy or long-term antibiotics. Of course these patients often require regular cross-sectional imaging with IV contrast. Power injector compatible versions of these have been shown to be safe [37], with a low 1% reported risk of adverse incident. Each type of catheter has maximal flow rate and pressure limits detailed by the manufacturer. However, there remains variability in practice and persistent concern regarding complications due to potentially high pressures achieved using pump injections of CM and how very few catheters have been studied for use with power injectors [38, 39]. Although rare, extravasation from central catheters can lead to significant morbidity, i.e. mediastinal extravasation, haematoma and cardiac arrhythmias.

Prior to the advent of power-injectable CVCs, the Medical and Healthcare Products Regulatory Agency (MHRA) in the UK published recommendations regarding rates and volumes for CM injections. However, these have been withdrawn and current advice is to follow specific manufacturer guidance. Plumb and Murphy recommended a maximum flow rate of 2.0 ml/s for CVC and to use the distal lumen if a multi-lumen CVC is in place [37]. A CT topogram is a good method to quickly evaluate catheter tip positioning post CM administration. Overall, extravasation injury is extremely rare with the main concern pertaining to mispositioning and tube integrity. Power injectable TIVADs have a growing role; a retrospective study did not find any incidence of CMEX in 307 patients studied over 4 years with injection rates of 3–5 ml/s employed. Although the evidence base for the use of these power injectable ports is limited, there has been no CMEX demonstrated [40]. Another retrospective study found similar findings [41] whilst Rigsby et al. also found pressure-limited power injection through central lines in children to be safe (no complications, 63 patients aged 0.3–22 years) [42].

Power injection compared to manual injection via peripherally inserted IV cannula

Sinan et al. did not find any significant difference in extravasation rates in patients receiving CM via power injection vs. manual injection [34]. A study by Barrera et al. of power injectors in children also found low rates of extravasation and long-term injury [43]. Preparation of the injector system is key to minimise the risk and departments should follow a standard protocol, i.e. correct alignment and clearing of syringe and pressure tubing.

Infusion rate and volume of CM

Six studies have assessed rate and volume impact on CMEX. A randomised controlled trial by Kok et al. demonstrated no significant difference in CMEX when assessing different flow rates (8.3 ml/s, 6.7 ml/s and 5.4 ml/s) [44]. However, different CM were used to ensure equivalent iodine delivery rate and load remained constant. Furthermore, a major confounding variable was that catheter size was not kept constant. Findings from other research groups [34, 34, 45, 46] are similar with the caveat that all have confounding factors of different cannula sizes and type of CM used. Whilst Wienbeck et al. found a statistically significant increase of extravasate volume with the use of high flow rates, Moreno et al. showed the converse of reduced extravasate volumes with higher flow rates [46]. The use of EDAs in this study appeared to reduce volumes of extravasate at higher rate injections.

Cannula insertion technical factors

A non-randomised retrospective study found higher rates of extravasation in patients who had ultrasound-guided cannula insertion (3.6%) vs. standard insertion (0.3%). However, the numbers of patients in each group were drastically different—364 in the ultrasound-guided cannula inserted group and 896 in the standard cannula inserted group (2% of a random sample of 40,143 patients). The difference in results in this study is likely due to confounding variables; i.e. prior failure of standard insertion and with deeper veins there is potentially a shorter length of intravascular cannula hence greater potential for dislodgement upon injection [47]. The type of healthcare worker who inserts the IV cannula was investigated by Sinan et al. which showed that CMEX rates were higher when inserted by non-radiology staff (0.3%) as compared to radiology staff (0.2%). However, this difference did not demonstrate statistical significance and a number of confounders could explain this difference [34]. Another study evaluated extravasation between newly inserted cannula vs. use of an existing cannula for CM injection with a difference in rates and a reduced volume of extravasate observed with those freshly sited (40.6 ml vs. 63.1 ml, p = 0.0005) [46], despite older cannulae being checked for flush efficacy. Therefore, consideration should be given to placing a new cannula for at-risk patients to reduce potential impact of any extravasation.

Chemical properties of CM

Three main contrast media properties have been studied in relation to CMEX: osmolarity, charge and viscosity.

Osmolarity—A relationship has been demonstrated between higher osmolarity CM (600, 1500 and 2100 mOsm/kg H2O) and cellular lysis which is thought to be a factor in the degree of tissue damage caused by extravasation. This has only been studied in animal models where old ionic CM (such as sodium and meglumine ioxithalamate) was used [48, 49]. Human clinical studies with non-ionic CM are lacking.

Ionicity—Charge can influence extravasation in that ionic CMs are thought to increase complications; however, ionic IBCMs are no longer used for intravenous studies. Studies have shown that non-ionic IBCMs (such as Iopamidol 300 and 370, and iohexol 300 and 350) are well tolerated in humans [30, 49, 50]. On the other hand, most GBCAs are ionic so this can potentially play a role in the severity of extravasation injury although volumes used are much lower and again human clinical studies are lacking.

Viscosity—This is thought to influence the likelihood of extravasation occurring. A computational fluid dynamics study by Sakellariou et al. demonstrated the potential for increased incidence of extravasation with more viscous CM, especially in CT angiography when performed with smaller peripheral cannulas [19]. A viscosity of > 9.4 mPa·s demonstrated increased risk of extravasation in the study by Hwang et al. [2]. An inverse relationship exists between viscosity and temperature in liquids; hence, warmed CMs are less viscous and offer lower resistance. Davenport et al. evaluated the role of warming CM to 37 degrees vs. CM at ambient temperature in > 20,000 patient contrast injection trialled with two contrast media. There was no significant difference in CMEX incidence between warmed versus ambient temperature Iopamidol 300. However, the higher viscosity Iopamidol 370 had an increased incidence of CMEX that was reduced (becoming similar to that with the lower viscosity CM) when the CM was warmed. There was, however, no effect on the volume of extravasate when CMEX occurred [51]. A recent study evaluating safety of Iomeprol 400, when warmed to 37 degrees, reported CME rate of 0.71% out of a total of 3,514 injections, with site and/or size of cannula not influencing CMEX rates [52]. However, the authors found inability to aspirate blood through the cannula significantly correlated with incidence of CMEX.

Overall, this suggests that using CM with lower viscosity and/or warming CM and/or diluting/mixing CM with saline has a preventative role in CMEX.

Gadolinium based contrast agents

There is much less data on rates of CMEX for MRI; the incidence of CMEX is reported as approximately 0.06% with no serious complications described—likely due to low infusion rates and lower CM volumes compared to IBCM uses. Theoretically, the extravasation of GBCAs could lead to oedema, necrosis or haemorrhage, potentially exacerbated due to their ionicity and higher osmolarity when compared to IBCM, although this does not seem to be borne out in practice [3, 48].

Patient-related factors

Based on a meta-analysis of 356,582 patients by Ding et al., females and older patients (> 60 years) are at greater risk of developing CMEX; however, gender and age have no impact on the volume of CM extravasation when it does occur [11]. In-patients are at an increased risk compared to those having outpatient scans, especially intravenous drug users and patients with recent hospitalisation [11]. Further risk factors include those patients with an inability to communicate, fragile veins, compromised venous and/or lymphatic drainage and obesity [1].

It is suggested based on the risk factors discussed in Table 3 that the measures outlined in Table 4 will greatly reduce the chances of extravasation occurring and minimise severity when it occurs.

Table 3.

Risk factors

Technique Patient

• Less optimal injection sites including lower limb and small distal veins

• Large volume of contrast medium

• High osmolarity contrast media

• Viscous contrast media

• Inability of patient to communicate

• Fragile or damaged veins

• Compromised lymphatic and/or venous drainage

• Obesity

Table 4.

Preventative and minimisation measures

Grade of recommendation*
Meticulous cannula insertion technique using an appropriate size upper arm vein is preferred C
An appropriately sized cannula for the vein and anticipated flow rate B
Test injection with saline prior to contrast administration D
Warming of the contrast medium, especially for higher viscosity compounds B
Minimising the volume of contrast administered based upon the indication and patient size B
Use of correct flow rates and pressures appropriate to the specific catheter, especially when using central venous catheters B
Effective detection protocol which allows early diagnosis, this ranges from direct observation to considering use of extravasation detection accessories in high-risk patients B

*Grade of recommendation (see Appendix 2)

What are the proposed treatments?

The untreated sequelae of severe CMEX are as follows: increased intra-compartmental pressure (compartment syndrome), with subsequent risk of ischemia due to venous congestion and low arterial gradient causing disproportionate necrosis, severe neurovascular compromise or even limb loss. Treatments to avoid these serious complications can be divided into passive conservative measures and more active therapies (Table 5).

Table 5.

Treatment of contrast media extravasation (CMEX)

Mechanisms and discussion of evidence
Conservative Treatments
  Aspiration of contrast whilst cannula still in place prior to removal. This reduces the volume of contrast extravasate and reduce pressure [57].
  Raise the affected limb if possible. Minimise oedema by reducing hydrostatic pressure and promoting drainage [58].
  Cooling of the region.A cold compress 15 to 60 minutes three times per day for a period of 3 to 4 days [1]. Anti-inflammatory effect via vasoconstriction and is widely recommended when treating CMEX [1, 13, 59].
  Warming of the region. Controversially, some think that cooling can delay resorption of extravasate, and warming can lead to vasodilation hence increasing contrast media (CM) resorption. Hastings-Tolsma et al. conducted studies with saline, assessing extravasation by the effect of both warming and cooling extremities [60]. No significant difference was observed between groups in terms of surface area induration, or evidence of extravasate taking longer to resorb when warm solution was applied.
  Heparin ointment dressing with cooling (where the dermis is intact). Anecdotal use has been suggested in a recent review paper by Mandlik et al. [12].
  Topical non-steroidal anti-inflammatory drugs (NSAIDs). Evidence only pertains to the analgesic effects on acute pain and not specifically extravasation [61].
Invasive treatments
  Hyaluronic acid injection (HYLA). Dose of between 5–250 Units is thought to be most effective [15]. This mucopolysaccharide is injected directly into the site of CMEX and is thought to work by enzymatically cleaving structures of the interstitium thus promoting resorption into vessels and lymphatics. Limited evidence supporting its use [62]. Indeed, some data does not support its use as some animal models have shown an increased inflammatory response [63]. Overall, not considered routine treatment (only off-label use e.g. inoperable patients with compartment syndrome due to CMEX).
  Aspiration & irrigation: essentially “wash-out” using stab incisions around the area of concern under local anaesthetic and extravasate aspirated with blunt suction cannulas. This is followed by irrigation (performed within 6 hours). There is variation as to the exact technique, based on a retrospective study by Gault in 96 patients with extravasation,  44 were successfully treated [64]. However, only 1 patient had a CMEX (others being chemotherapy agents etc.) meaning it may be less applicable to CMEX. Further case series of 11 patients by Vandeweyer et al. described successful use, although this was with high osmolarity, ionic agents [65]. Overall, this is a mechanistically plausible method but without strong evidence base for routine use.
  Manual squeezing technique: manual expression of extravasate after various punctures/stab incisions (e.g. 5–10 stabs with 18G needle). Study by Tsai et al. of 8 cases who developed vascular compromise with 50 - 80 ml of non-ionic, low osmolarity extravasate demonstrated satisfactory healing using this method [66]. A similar study by Kim et al. with 23 cases (no control group) of extravasate > 50 ml also showed satisfactory response after 1 week follow-up although there was immediate temporary mild blistering [67]. A similar technique whereby multiple stab incisions were made for large volume extravasations was found to be successful in a case report by Raveendran et al. [68] Similar to other techniques, limited data available to support use of this, but the simplicity is attractive and more comparative data would help assess efficacy.
  Fasciotomy and compartment release Considered the definitive surgical treatment when a CMEX is complicated by neurovascular compromise or compartment syndrome. A retrospective study by Fallscheer et al., identified seven patients required fasciotomy [54]. Delay to refer to plastic surgery by >300 minutes is the greatest risk factor contributing to complications post-operatively.

Studies assessing conservative methodologies to treat extravasation events are few and not of robust quality in terms of applicability for radiology, i.e. laboratory-based studies or investigations of extravasation of cytotoxic drugs rather than contrast media. Most recommendations are based on “good clinical practice”. The aim of conservative measures is to reduce the morbidity associated with CMEX. The evidence base for use of invasive treatments is limited with mostly retrospective studies, small case numbers, lack of control groups, data based on older CM or even not CMEX.

It is important that clear instructions to the patient who has suffered CMEX are given regarding when to seek additional medical care if there are worsening symptoms. A patient information leaflet is recommended, available in the languages appropriate for the institution. Patients should be warned about red flag signs and symptoms which are as follows:

  • Increased swelling or pain

  • Increased redness

  • Change in sensation in the affected limb

  • Skin ulceration or blistering

In Table 6, we outline a suggested protocol for the management of contrast media extravasations.

Table 6.

Suggested protocol for management of contrast media extravasation

Grade of recommendation*
Conservative
• Stop injection and scan—classify as mild, moderate, or severe D
• Accurate documentation, demarcate area affected and consult responsible physician C
• Mild cases: limb elevation, ice packs, monitor patient 2–4 hourly. If improving, then discharge. If no improvement, then requires surgical opinion C
• Radiographic documentation for moderate and severe cases—two orthogonal views or cross-sectional imaging can help assess compartmentalization and extent of extravasation C
• Record extravasation as a complication in radiology report and the local incident reporting system C
• Patient information leaflet should be given to patient C
• Follow-up appointment, if necessary D
Active
• If severe injury (e.g. neurovascular compromise, compartment syndrome, tissue necrosis) suspected then urgently seek advice of a surgeon B
• Surgical opinion also recommended for extravasate > 150 ml C

*Grade of recommendation (see Appendix 2)

When to get a surgical consult?

Compartment syndrome is the most serious among the consequences of CMEX. It is extremely rare with less than 12 cases reported in a recent literature review however must be suspected if patient complains of severe pain and/or neurovascular compromise [53]. Signs which would necessitate fasciotomy being painful active flexion, passive extension, neurosensory disturbance and increasing swelling. Locations which are most at risk are volar forearm and the hand. Whilst a radiologist can attend to mild cases, in more severe cases, a surgeon should be urgently consulted, and fasciotomy should be performed within 2 h to avoid muscle necrosis and nerve damage. Surgery performed within 90 to 300 min has been reported to conserve all extremities with favourable prognosis [54]. Sbitany et al. in a study of 102 cases of CMEX used a threshold of 30 ml extravasate as a referral prompt [55] and none required surgery, even in the 10% with > 100 ml CMEX volume. Wang et al. reported similar findings where even extravasate volumes of up to 150 ml of non-ionic IBCM were conservatively managed, suggesting no discrete threshold extravasate volume should be set [56]. Dykes et al. suggest that larger extravasated volumes correlate with moderate-to-severe injuries, but the data does not support using a volume threshold to determine surgical referral or more aggressive management [23]. Nevertheless, in unusual cases with very large volumes of extravasate (> 150 ml), the consensus remains that surgical consult is appropriate.

Overall, the decision to refer for surgical intervention should be a clinical one—i.e. based on red flag signs and symptoms, rather than arbitrary CMEX volumes.

Conclusion

This review highlights the key up-to-date evidence pertaining to CMEX summarising the important risk factors and a systematic approach to management. Whilst this review has been all encompassing, there are some limitations. Heterogeneity of the studies included in the paper have made performing a meta-analysis tricky and often difficult to compare data across different types of studies. Most of the studies are retrospective and with rates of CMEX being generally low, there are inadequately statically powered studies. There have been technological changes in CT and MRI, especially with use of non-ionic CM, increased understanding of the risk factors and use of EDAs as well as systems which halt injection if problems are encountered during infusion, all of which inform update on the previous guidelines. However, there remain important areas where further research would be merited. There is no data available on patient experience of CMEX and this is an important impact to explore as the patient may refuse to have CM in the future. Long-term follow-up of patients after CMEX and prospective trials with CMEX interventions are also not well-researched. Important questions to ask are appropriate time interval when to re-scan after a CMEX, impact on workflow and cost implications.

Supplementary Information

Below is the link to the electronic supplementary material.

Abbreviations

CM

Contrast media

CMEX

Contrast media extravasation

CT

Computed tomography

EDA

Extravasation detection accessory

GBCA

Gadolinium-based contrast agent

IBCM

Iodine-based contrast media

IV

Intravenous

MeSH

Medical subject headings

MRI

Magnetic resonance imaging

OCEBM

Oxford Centre for Evidence-Based Medicine*

Funding

The authors state that this work has not received any funding.

Declarations

Guarantor

The scientific guarantor of this publication is Olivier Clément.

Conflict of interest

The authors of this manuscript declare relationships with the following companies:

Giles Roditi: none.

Nadir Khan: none.

Aart J. van der Molen: Bayer Healthcare.

Marie-France Bellin: none.

Michele Bertolotto: none.

Torkel Brismar: none.

Jean-Michel Correas: Bracco, Guerbet.

Ilona A. Dekkers: none.

Remy W.F. Geenen: none.

Gertraud Heinz-Peer: none.

Andreas H. Mahnken: none.

Carlo C. Quattrocchi: none.

Alexander Radbruch: Bracco, Guerbet, Bayer, GE.

Peter Reimer: none.

Laura Romanini: none.

Fulvio Stacul: none.

Henrik S. Thomsen: pending.

Olivier Clément: Bracco, Guerbet, Bayer Healthcare.

M.F.B., T.B. and F.S. are members of the European Radiology Editorial Board. They have not taken part in the review or selection process of this article.

Statistics and biometry

One of the authors has significant statistical expertise (Ilona Dekkers).

Informed consent

Not applicable.

Ethical approval

Not applicable.

Study subjects or cohorts overlap

Not applicable.

Methodology

• retrospective

Footnotes

*OCEBM Levels is a critical appraisal tool designed by an international group which allows evaluation of the strength of evidence for a range of clinical questions, i.e. prevalence, accuracy of diagnostic tests, prognosis, therapeutic effects, rare and common harms, and usefulness of screening.

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Giles Roditi and Nadir Khan Both contributed equally to this work

References

  • 1.Bellin M-F, Jakobsen JA, Tomassin I, et al. Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol. 2002;12:2807–2812. doi: 10.1007/s00330-002-1630-9. [DOI] [PubMed] [Google Scholar]
  • 2.Hwang EJ, Shin C-I, Choi YH, Park CM. Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans. Eur Radiol. 2018;28:5368–5375. doi: 10.1007/s00330-018-5507-y. [DOI] [PubMed] [Google Scholar]
  • 3.Heshmatzadeh Behzadi A, Farooq Z, Newhouse JH, Prince MR (2018) MRI and CT contrast media extravasation. Medicine (Baltimore) 97.10.1097/MD.0000000000010055 [DOI] [PMC free article] [PubMed]
  • 4.Wilson BG. Contrast media-induced compartment syndrome. Radiol Technol. 2011;83:63–77. [PubMed] [Google Scholar]
  • 5.Benson LS, Sathy MJ, Port RB. Forearm compartment syndrome due to automated injection of computed tomography contrast material. J Orthop Trauma. 1996;10:433–436. doi: 10.1097/00005131-199608000-00012. [DOI] [PubMed] [Google Scholar]
  • 6.Belzunegui T, Louis CJ, Torrededia L, Oteiza J. Extravasation of radiographic contrast material and compartment syndrome in the hand: a case report. Scand J Trauma Resusc Emerg Med. 2011;19:9. doi: 10.1186/1757-7241-19-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Alami Z, Nasri S, Ahid S, Kacem HH (2015) Extravasation of contrast medium during CT examination: an observational case-control study. Pan Afr Med J 20. 10.11604/pamj.2015.20.89.3276 [DOI] [PMC free article] [PubMed]
  • 8.Kyung E-J, Ryu J-H, Kim E-Y (2013) Evaluation of adverse reactions to contrast media in the hospital. Br J Radiol 86.10.1259/bjr.20130418 [DOI] [PMC free article] [PubMed]
  • 9.van der Molen AJ, Reimer P, Dekkers IA, et al. Post-contrast acute kidney injury - Part 1: definition, clinical features, incidence, role of contrast medium and risk factors : Recommendations for updated ESUR Contrast Medium Safety Committee guidelines. Eur Radiol. 2018;28:2845–2855. doi: 10.1007/s00330-017-5246-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.van der Molen AJ, Reimer P, Dekkers IA, et al. Post-contrast acute kidney injury. Part 2: risk stratification, role of hydration and other prophylactic measures, patients taking metformin and chronic dialysis patients. Eur Radiol. 2018;28:2856–2869. doi: 10.1007/s00330-017-5247-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Ding S, Meystre NR, Campeanu C, Gullo G. Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions. JBI Database System Rev Implement Rep. 2018;16:87–116. doi: 10.11124/JBISRIR-2017-003348. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Mandlik V, Prantl L, Schreyer AG. Contrast media extravasation in CT and MRI - a literature review and strategies for therapy. Rofo. 2019;191:25–32. doi: 10.1055/a-0628-7095. [DOI] [PubMed] [Google Scholar]
  • 13.Hrycyk J, Heverhagen JT. Boehm I (2019) What you should know about prophylaxis and treatment of radiographic and magnetic resonance contrast medium extravasation. Acta Radiol. 1987;60:496–500. doi: 10.1177/0284185118782000. [DOI] [PubMed] [Google Scholar]
  • 14.Guyatt GH, Oxman AD, Kunz R, et al. GRADE guidelines: 2. Framing the question and deciding on important outcomes. J Clin Epidemiol. 2011;64:395–400. doi: 10.1016/j.jclinepi.2010.09.012. [DOI] [PubMed] [Google Scholar]
  • 15.Dijkmans PA, Visser CA, Kamp O. Adverse reactions to ultrasound contrast agents: is the risk worth the benefit? Eur J Echocardiogr. 2005;6:363–366. doi: 10.1016/j.euje.2005.02.003. [DOI] [PubMed] [Google Scholar]
  • 16.Rosado E, Riccabona M. Off-label use of ultrasound contrast agents for intravenous applications in children: analysis of the existing literature. J Ultrasound Med. 2016;35:487–496. doi: 10.7863/ultra.15.02030. [DOI] [PubMed] [Google Scholar]
  • 17.Hu C, Feng Y, Huang P, Jin J (2019) Adverse reactions after the use of SonoVue contrast agent. Medicine (Baltimore) 98.10.1097/MD.0000000000017745 [DOI] [PMC free article] [PubMed]
  • 18.Lewis GB, Hecker JF. Radiological examination of failure of intravenous infusions. Br J Surg. 1991;78:500–501. doi: 10.1002/bjs.1800780437. [DOI] [PubMed] [Google Scholar]
  • 19.Sakellariou S, Li W, Paul MC, Roditi G. Rôle of contrast media viscosity in altering vessel wall shear stress and relation to the risk of contrast extravasations. Med Eng Phys. 2016;38:1426–1433. doi: 10.1016/j.medengphy.2016.09.016. [DOI] [PubMed] [Google Scholar]
  • 20.Selek H, Ozer H, Aygencel G, Turanli S. Compartment syndrome in the hand due to extravasation of contrast material. Arch Orthop Trauma Surg. 2007;127:425–427. doi: 10.1007/s00402-006-0238-y. [DOI] [PubMed] [Google Scholar]
  • 21.Tonolini M, Campari A, Bianco R. Extravasation of radiographic contrast media: prevention, diagnosis, and treatment. Curr Probl Diagn Radiol. 2012;41:52–55. doi: 10.1067/j.cpradiol.2011.07.004. [DOI] [PubMed] [Google Scholar]
  • 22.Cleary N, McNulty JP, Foley SJ, Kelly E. An investigation into current protocols and radiographer opinions on contrast extravasation in Irish CT departments. Radiography (Lond) 1995. 2017;23:e87–e92. doi: 10.1016/j.radi.2017.05.009. [DOI] [PubMed] [Google Scholar]
  • 23.Dykes TM, Bhargavan-Chatfield M, Dyer RB. Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol. 2015;12:183–191. doi: 10.1016/j.jacr.2014.07.021. [DOI] [PubMed] [Google Scholar]
  • 24.Birnbaum BA, Nelson RC, Chezmar JL, Glick SN. Extravasation detection accessory: clinical evaluation in 500 patients. Radiology. 1999;212:431–438. doi: 10.1148/radiology.212.2.r99au14431. [DOI] [PubMed] [Google Scholar]
  • 25.Nelson RC, Anderson FA, Birnbaum BA, et al. Contrast media extravasation during dynamic CT: detection with an extravasation detection accessory. Radiology. 1998;209:837–843. doi: 10.1148/radiology.209.3.9844684. [DOI] [PubMed] [Google Scholar]
  • 26.Powell CC, Li JM, Rodino L, Anderson FA. A new device to limit extravasation during contrast-enhanced CT. AJR Am J Roentgenol. 2000;174:315–318. doi: 10.2214/ajr.174.2.1740315. [DOI] [PubMed] [Google Scholar]
  • 27.Saade C, Brennan P. Clinical implementation of the new MEDRAD XDS contrast extravasation detector for multidetector computed tomography. J Med Imaging Radiat Sci. 2011;42:179–182. doi: 10.1016/j.jmir.2011.05.003. [DOI] [PubMed] [Google Scholar]
  • 28.Hoff L, Brabrand K, Andersen NB, Medhus S. Monitoring X-ray contrast agent injections with Doppler ultrasound. IEEE Ultrason Symp. 2008;2008:13–16. [Google Scholar]
  • 29.Teo M, Ong C, Ying A, Hng M (2015) Extravasation of contrast medium during CT scanning – tracking and reduction of rate of extravasation. https://posterng.netkey.at/esr/viewing/index.php?module=viewing_poster&task=viewsection&pi=126853&ti=422983&si=1478&searchkey=. Accessed 16 Oct 2019
  • 30.Cohan RH. Considering large-volume intravenous injections of iodinated contrast media for contrast-enhanced CT (head and body) AJR Am J Roentgenol. 1995;164:1292. doi: 10.2214/ajr.164.5.7717251. [DOI] [PubMed] [Google Scholar]
  • 31.Tonolini M. Contrast medium extravasation: the importance of radiographic assessment. Curr Probl Diagn Radiol. 2016;45:236–237. doi: 10.1067/j.cpradiol.2016.02.002. [DOI] [PubMed] [Google Scholar]
  • 32.Johnson PT, Christensen GM, Fishman EK. I.v. contrast administration with dual source 128-MDCT: a randomized controlled study comparing 18-gauge nonfenestrated and 20-gauge fenestrated catheters for catheter placement success, infusion rate, image quality, and complications. AJR Am J Roentgenol. 2014;202:1166–1170. doi: 10.2214/AJR.13.11730. [DOI] [PubMed] [Google Scholar]
  • 33.Wienbeck S, Fischbach R, Kloska SP, et al. Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. AJR Am J Roentgenol. 2010;195:825–829. doi: 10.2214/AJR.09.3739. [DOI] [PubMed] [Google Scholar]
  • 34.Sinan T, Al-Khawari H, Chishti FA, Al Saeed OM, Sheikh M (2005) Contrast media extravasation: manual versus power injector. Med Princ Pract 14:107–110 [DOI] [PubMed]
  • 35.Schwab SA, Uder M, Anders K, et al. Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study. Rofo. 2009;181:355–361. doi: 10.1055/s-0028-1109181. [DOI] [PubMed] [Google Scholar]
  • 36.Amaral JG, Traubici J, BenDavid G, et al. Safety of power injector use in children as measured by incidence of extravasation. AJR Am J Roentgenol. 2006;187:580–583. doi: 10.2214/AJR.05.0667. [DOI] [PubMed] [Google Scholar]
  • 37.Plumb AAO, Murphy G. The use of central venous catheters for intravenous contrast injection for CT examinations. Br J Radiol. 2011;84:197–203. doi: 10.1259/bjr/26062221. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Buijs SB, Barentsz MW, Smits MLJ, et al. Systematic review of the safety and efficacy of contrast injection via venous catheters for contrast-enhanced computed tomography. Eur J Radiol Open. 2017;4:118–122. doi: 10.1016/j.ejro.2017.09.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Radiological Society of the Netherlands (2019) Guideline safe use of contrast media part 2. Radiological Society of the Netherlands, Utrecht. https://www.radiologen.nl/sites/default/files/secties/abdominale/richtlijnen/guideline_safe_use_of_contrast_media_part_2.pdf. Accessed 26 Oct 2020
  • 40.Alexander MD, Morrison HL. Power-injectable ports: safety during placement, therapeutic use, and contrast administration during computed tomography procedures. J Vasc Access. 2012;13:432–437. doi: 10.5301/jva.5000074. [DOI] [PubMed] [Google Scholar]
  • 41.Goltz JP, Machann W, Noack C, et al. Feasibility of power contrast injections and bolus triggering during CT scans in oncologic patients with totally implantable venous access ports of the forearm. Acta Radiol. 2011;52:41–47. doi: 10.1258/ar.2010.100238. [DOI] [PubMed] [Google Scholar]
  • 42.Rigsby CK, Gasber E, Seshadri R, et al. Safety and efficacy of pressure-limited power injection of iodinated contrast medium through central lines in children. AJR Am J Roentgenol. 2007;188:726–732. doi: 10.2214/AJR.06.0104. [DOI] [PubMed] [Google Scholar]
  • 43.Barrera CA, White AM, Shepherd AM, et al. Contrast Extravasation using power injectors for contrast-enhanced computed tomography in children: frequency and injury severity. Acad Radiol. 2019 doi: 10.1016/j.acra.2019.04.008. [DOI] [PubMed] [Google Scholar]
  • 44.Kok M, Mihl C, Hendriks BMF, et al. Patient comfort during contrast media injection in coronary computed tomographic angiography using varying contrast media concentrations and flow rates: results from the EICAR trial. Invest Radiol. 2016;51:810–815. doi: 10.1097/RLI.0000000000000284. [DOI] [PubMed] [Google Scholar]
  • 45.Shaqdan K, Aran S, Thrall J, Abujudeh H. Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: a report on 502,391 injections. Clin Radiol. 2014;69:1264–1272. doi: 10.1016/j.crad.2014.08.004. [DOI] [PubMed] [Google Scholar]
  • 46.Moreno CC, Pinho D, Nelson RC, et al. Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate. J Comput Assist Tomogr. 2013;37:286–288. doi: 10.1097/RCT.0b013e31828211da. [DOI] [PubMed] [Google Scholar]
  • 47.Rupp JD, Ferre RM, Boyd JS, et al. Extravasation risk using ultrasound-guided peripheral intravenous catheters for computed tomography contrast administration. Acad Emerg Med. 2016;23:918–921. doi: 10.1111/acem.13000. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Cohan RH, Leder RA, Herzberg AJ, et al. Extravascular toxicity of two magnetic resonance contrast agents. Preliminary experience in the rat. Invest Radiol. 1991;26:224–226. doi: 10.1097/00004424-199103000-00005. [DOI] [PubMed] [Google Scholar]
  • 49.Cohan RH, Ellis JH, Garner WL. Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology. 1996;200:593–604. doi: 10.1148/radiology.200.3.8756899. [DOI] [PubMed] [Google Scholar]
  • 50.Miles SG, Rasmussen JF, Litwiller T, Osik A. Safe use of an intravenous power injector for CT: experience and protocol. Radiology. 1990;176:69–70. doi: 10.1148/radiology.176.1.2353114. [DOI] [PubMed] [Google Scholar]
  • 51.Davenport MS, Wang CL, Bashir MR, et al. Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37°C. Radiology. 2012;262:475–484. doi: 10.1148/radiol.11111282. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Stroeder J, Fries P, Raczeck P, et al. Prospective safety evaluation of automated iomeprol 400 injections for CT through peripheral venous cannulas. Clin Radiol. 2020;75:396.e1–396.e6. doi: 10.1016/j.crad.2019.12.013. [DOI] [PubMed] [Google Scholar]
  • 53.van Veelen NM, Link B-C, Donner G, et al. Compartment syndrome of the forearm caused by contrast medium extravasation: a case report and review of the literature. Clin Imaging. 2020;61:58–61. doi: 10.1016/j.clinimag.2020.01.013. [DOI] [PubMed] [Google Scholar]
  • 54.Fallscheer P, Kammer E, Roeren T, Meuli-Simmen C. Injury to the upper extremity caused by extravasation of contrast medium: a true emergency. Scand J Plast Reconstr Surg Hand Surg. 2007;41:26–32. doi: 10.1080/02844310601088221. [DOI] [PubMed] [Google Scholar]
  • 55.Sbitany H, Koltz PF, Mays C, et al. CT contrast extravasation in the upper extremity: strategies for management. Int J Surg Lond Engl. 2010;8:384–386. doi: 10.1016/j.ijsu.2010.06.002. [DOI] [PubMed] [Google Scholar]
  • 56.Wang CL, Cohan RH, Ellis JH, et al. Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections. Radiology. 2007;243:80–87. doi: 10.1148/radiol.2431060554. [DOI] [PubMed] [Google Scholar]
  • 57.Khan MS, Holmes JD (2002) Reducing the morbidity from extravasation injuries. Ann Plast Surg 48:628–632; discussion 632. 10.1097/00000637-200206000-00011 [DOI] [PubMed]
  • 58.Nicola R, Shaqdan KW, Aran S, et al. Contrast media extravasation of computed tomography and magnetic resonance imaging: management guidelines for the radiologist. Curr Probl Diagn Radiol. 2016;45:161–164. doi: 10.1067/j.cpradiol.2015.08.004. [DOI] [PubMed] [Google Scholar]
  • 59.Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiogr Rev Publ Radiol Soc N Am Inc 35:1738–1750 [DOI] [PubMed]
  • 60.Hastings-Tolsma MT, Yucha CB, Tompkins J, et al. Effect of warm and cold applications on the resolution of i.v. infiltrations. Res Nurs Health. 1993;16:171–178. doi: 10.1002/nur.4770160304. [DOI] [PubMed] [Google Scholar]
  • 61.Massey T, Derry S, Moore RA, McQuay HJ (2010) Topical NSAIDs for acute pain in adults. Cochrane Database Syst Rev CD007402. 10.1002/14651858.CD007402.pub2 [DOI] [PMC free article] [PubMed]
  • 62.Federle MP, Chang PJ, Confer S, Ozgun B. Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology. 1998;206:637–640. doi: 10.1148/radiology.206.3.9494479. [DOI] [PubMed] [Google Scholar]
  • 63.McAlister WH, Kissane JM. Comparison of soft tissue effects of conventional ionic, low osmolar ionic and nonionic iodine containing contrast material in experimental animals. Pediatr Radiol. 1990;20:170–174. doi: 10.1007/BF02012965. [DOI] [PubMed] [Google Scholar]
  • 64.Gault DT. Extravasation injuries. Br J Plast Surg. 1993;46:91–96. doi: 10.1016/0007-1226(93)90137-Z. [DOI] [PubMed] [Google Scholar]
  • 65.Vandeweyer E, Heymans O, Deraemaecker R. Extravasation injuries and emergency suction as treatment. Plast Reconstr Surg. 2000;105:109–110. doi: 10.1097/00006534-200001000-00019. [DOI] [PubMed] [Google Scholar]
  • 66.Tsai YS, Cheng SM, Ng SP, et al. Squeeze maneuver: an easy way to manage radiological contrast-medium extravasation. Acta Radiol. 2007;48:605–607. doi: 10.1080/02841850701324094. [DOI] [PubMed] [Google Scholar]
  • 67.Kim SM, Cook KH, Lee IJ, et al. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions. Int Wound J. 2017;14:430–434. doi: 10.1111/iwj.12628. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 68.Raveendran S, Rajendra Benny K, Monica S, et al. Multiple Stab incisions and evacuation technique for contrast extravasation of the hand and forearm. J Hand Surg. 2019;44:71.e1–71.e5. doi: 10.1016/j.jhsa.2018.08.009. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials


Articles from European Radiology are provided here courtesy of Springer

RESOURCES