Abstract
Biosensors with high sensitivity, selectivity and a low limit of detection, reaching nano/picomolar concentrations of biomolecules, are important to the medical sciences and healthcare industry for evaluating physiological and metabolic parameters. Over the last decade, different nanomaterials have been exploited to design highly efficient biosensors for the detection of analyte biomolecules. The discovery of graphene has spectacularly accelerated research on fabricating low-cost electrode materials because of its unique physical properties, including high specific surface area, high carrier mobility, high electrical conductivity, flexibility, and optical transparency. Graphene and its oxygenated derivatives, including graphene oxide (GO) and reduced graphene oxide (rGO), are becoming an important class of nanomaterials in the field of biosensors. The presence of oxygenated functional groups makes GO nanosheets strongly hydrophilic, facilitating chemical functionalization. Graphene, GO and rGO nanosheets can be easily combined with various types of inorganic nanoparticles, including metals, metal oxides, semiconducting nanoparticles, quantum dots, organic polymers and biomolecules, to create a diverse range of graphene-based nanocomposites with enhanced sensitivity for biosensor applications. This review summarizes the advances in two-dimensional (2D) and three-dimensional (3D) graphene-based nanocomposites as emerging electrochemical and fluorescent biosensing platforms for the detection of a wide range of biomolecules with enhanced sensitivity, selectivity and a low limit of detection. The biofunctionalization and nanocomposite formation processes of graphene-based materials and their unique properties, surface functionalization, enzyme immobilization strategies, covalent immobilization, physical adsorption, biointeractions and direct electron transfer (DET) processes are discussed in connection with the design and fabrication of biosensors. The enzymatic and nonenzymatic reactions on graphene-based nanocomposite surfaces for glucose- and cholesterol-related electrochemical biosensors are analyzed. This review covers a very broad range of graphene-based electrochemical and fluorescent biosensors for the detection of glucose, cholesterol, hydrogen peroxide (H2O2), nucleic acids (DNA/RNA), genes, enzymes, cofactors nicotinamide adenine dinucleotide (NADH) and adenosine triphosphate (ATP), dopamine (DA), ascorbic acid (AA), uric acid (UA), cancer biomarkers, pathogenic microorganisms, food toxins, toxic heavy metal ions, mycotoxins, and pesticides. The sensitivity and selectivity of graphene-based electrochemical and fluorescent biosensors are also examined with respect to interfering analytes present in biological systems. Finally, the future outlook for the development of graphene based biosensing technology is outlined.
Biosensors with high sensitivity, selectivity and a low limit of detection, reaching nano/picomolar concentrations of biomolecules, are important to the medical sciences and healthcare industry for evaluating physiological and metabolic parameters.
1. Introduction
Biosensors with high sensitivity, able to detect femto- or pico-molar concentrations of analyte molecules, are of paramount importance not only in biomedical applications such as glucose monitoring and clinical diagnostics1 but also in the agriculture2 and food industries3 and environmental monitoring.4,5 The development of highly sensitive devices and new approaches that can provide efficient point-of-care testing with high accuracy and low cost is an urgent need in the healthcare industry.6–8 In addition, in vivo biosensors have received attention since they enable the long-term monitoring of target analytes within live cells with high sensitivity, selectivity and biocompatibility.9,10 Notably, biosensor research is considered to be an important field since it covers a wide range of sensing capabilities, including pulse, heart rate, blood pressure, body motions, blood oxygen level, glucose, cholesterol, antibodies, nucleic acids, proteins, cancer cells, toxins in food products, and heavy metals in drinking water.11–13 Numerous approaches have been explored, including colorimetric biosensors,14 potentiometric biosensors,15 electrochemical biosensors,16 fluorescent biosensors,17 and Raman spectroscopy-based platforms.18 Compared with other detection methods, an electrochemistry-19,20 and fluorescence-based21 approach offers a much less expensive, more facile and highly sensitive detection method, which enables the monitoring of different analytes, fast response–recovery times and very low detection limits.22
After the discovery of buckminsterfullerene (C60) molecules in 1985, the field of nanotechnology focused intently on developing new materials and devices within the 1–100 nm scale because nanoscale materials show unique chemical and physical properties compared to their counterpart bulk materials.23 A wide variety of nanoscale materials have been developed, including zero-dimensional (0D) nanoparticles (such as metallic and semiconducting nanoparticles),24,25 one-dimensional (1D) nanostructures (nanowires, nanorods, nanotubes),26 and two-dimensional (2D) nanostructures including graphene nanosheets (GNs), transition metal dichalcogenides (TMDs), etc.,27 with substantial progress on their synthesis, processing, characterization and potential applications. Over the past two decades, these nanoscale materials have been used in many applications, including light-emitting diodes, memory devices, communication devices, magnetic disks, solar cells, batteries, fuel cells, supercapacitors, and catalysts.28,29 Interfacing with various probe biomolecules has been studied in order to develop highly sensitive biosensors with significantly enhanced sensitivity.30 Due to the size and unprecedented physical properties of these nanomaterials, the development of biosensors with extremely small dimensions and substantially improved performance is possible, introducing new opportunities in the development and commercialization of next-generation biosensors for biomedicine and healthcare fields.31
Since the initial isolation of graphene from bulk graphite and characterization in 2004 by Geim and Novoselov,32 intensive research efforts have been directed toward 2D graphene nanomaterials and their potential applications.33–36 Graphene (GR) is a 2D sheet of carbons with atomic thickness that exhibits unique electrical, optical, mechanical and thermal properties.37 Graphene nanosheets can be easily exfoliated from earth-abundant graphite and are considered allotropically similar to fullerenes and carbon nanotubes. Graphene can be easily processed into single-layer, few-layer or multi-layer nanosheets,38 stretchable ultrathin films,39 papers,40 nanoribbons,41 and foams.42,43 Single-layer graphene nanosheets exhibit a high mechanical strength with a Young's modulus of 1.1 TPa,40 thermal conductivity of ∼5000 W m K−1,44 high carrier mobility (200 000 cm2 V−1 s−1),45 high optical transparency toward visible light (∼2.3% absorption)46 and a large specific surface area (2630 m2 g−1).47 As a result, graphene-based materials (GBMs) have been explored for a wide range of applications, including bulk-heterojunction48 and dye-sensitized solar cells,49 energy storage devices,50 electronic skin and touchscreen-panel devices,51 field effect transistors,52 light-emitting diodes (LEDs),53 gas and chemical sensors,54 nanomedicine,37 drug delivery,55 and many other applications.56 Graphene and its oxidized derivatives, such as graphene oxide (GO), which contain various oxygen functional groups (hydroxyl, carboxyl and epoxy functional groups), have emerged for potential use in biosensors.57 The presence of these functional groups makes GO sheets strongly hydrophilic and allows the integration of various types of inorganic nanoparticles, including noble metals, metal oxides, semiconducting nanoparticles, quantum dots (QDs), and nanoclusters (NCs), to enhance the performance of sensors based on them.58,59 Moreover, the reduction of GO into reduced GO (rGO) results in a high density of defects that leads to high electrochemical activity compared with that of CVD-grown graphene, which is particularly useful for developing electrochemical biosensors. Graphene-based nanocomposites also inherit unique morphological structures and properties useful for sensing.60 The 3D interconnected hierarchical structures of graphene nanocomposites facilitate the diffusion of different types of biomolecules and preserve their biocatalytic functions to optimize biosensing functionality.61–63 Graphene-based hybrids with polymers64,65 and surface-decorated metal nanoparticles58 have been explored for biosensing due to their excellent biocompatibility, high surface area, and site-selective conjugation with biomolecules.
Various nanostructures have been explored for biosensors, including the detection of glucose and hydrogen peroxide,66 cancer biomarkers,67–69 nucleic acids,11 antibodies,70 heavy metals,71,72 pathogenic bacteria,73 and many other targets19,74–77 However, no comprehensive review focused on a wide range of electrochemical and fluorescent biosensors utilizing graphene-based nanocomposites is yet available in the literature. There are no reviews on graphene-based fluorescent biosensors. Therefore, this review is intended to summarize the recent advances in both electrochemical and fluorescent biosensors based on graphene nanocomposites, including graphene, GO, rGO/polymer nanocomposites, graphene/inorganic NP nanocomposites, 3D graphene integrated with various metal/metal oxide nanoparticles, and polymer hydrogel networks. Biosensor systems to detect glucose, hydrogen peroxide (H2O2), cholesterol, dopamine (DA), ascorbic acid (AA), uric acid (UA), nucleic acids (NAs), cofactors nicotinamide adenine dinucleotide (NADH) and adenosine triphosphate (ATP), cancer biomarkers, pathogens, food toxins, metal ions and pesticides are discussed. The discussion focuses primarily on advances in enzymatic and nonenzymatic electrochemical platforms as well as conceptual advances in fluorescent biosensing and amplified detection techniques. The selectivity of graphene-based electrochemical and fluorescent biosensors are also examined in biological systems with respect to interfering analytes. This review will provide a single reference source for researchers in biosensors, graphene, materials science, nanotechnology, chemistry, and electrochemistry. Therefore, this review will attract a wide range of audiences from diverse research areas and stimulate further interest in graphene-based biosensors for future sensor industries.
2. Graphene-based nanocomposites
Numerous strategies have been developed for the synthesis of graphene.37,57,78–81 The synthesis of graphene and its graphene oxide (GO) and reduced graphene oxide (rGO) derivatives is illustrated in Fig. 1A. Four different routes have been commonly used to prepare graphene, namely, epitaxial growth on SiC or metals,82 chemical exfoliation of graphite,83 liquid-phase ultrasonic exfoliation of graphite powder,83 and chemical vapor deposition (CVD).84 In addition to these approaches, graphene nanosheets have been prepared by the electrochemical exfoliation of ionic liquid-functionalized graphite85 and by electrical arc discharge between two graphitic electrodes86,87 Though the CVD process is considered a primary route to synthesize high-quality, large-area graphene nanosheets of different layers and sizes, CVD-grown graphene nanosheets exhibit relatively low electrocatalytic activity due to the low number of structural defects. The physicochemical properties and surface features of graphene can be effectively altered by using nitrogen (N), boron (B), phosphorus (P), and sulfur (S) heteroatom doping.88 Numerous approaches have been used for chemical doping, including in situ doping, where the synthesis and doping of graphene are achieved simultaneously, for example, in CVD, ball milling, and bottom-up synthetic techniques. The highly controlled S-doped graphene (S-GR) nanostructure prepared by the ball milling technique is shown in Fig. 1B.
Graphene oxide (GO) consists of hydrophobic sp2- and sp3-bonded carbon and different oxygen-containing functional groups including hydroxyl (–OH), carbonyl, epoxy and carboxyl (–COOH) groups on the basal plane as well as at the edges of GO nanosheet.91,92 Similar to graphene, GO also exhibits unique electronic, electrochemical, thermal, and mechanical properties and can be developed into flexible, transparent, and biocompatible nanosheets due to its hydrophilic nature. The availability of functional groups on GO nanosheets facilitates their interaction with a wide range of biomolecules, which is highly advantageous for developing biosensors.78,93,94 GO nanosheets have been synthesized by the Brodie, Staudenmaier, and Hummers methods and by modified versions thereof.95,96 Furthermore, the reduction of GO into reduced GO (rGO) can be accomplished by reducing the GO employing chemical, electrochemical, high-temperature thermal annealing, and ultra-violet irradiation methods.91,96–99 The rGO also exhibits excellent properties; including solvent dispersibility; electrical, optical, and mechanical properties; and thermal stability comparable to those of graphene and GO nanosheets. Graphene quantum dots (GQDs) have also appeared as a novel class of zero-dimensional (0D) graphene derivatives possessing unique properties with quantum confinement and edge effects for biosensor applications.100–108
The hybridization of GBMs with different types of organic polymers, metal nanoparticles and surface functionalities with diverse enzymes and proteins is quite useful in developing new biosensors.64,109,110 In particular, both GO and rGO have been extensively used for developing nanocomposite-based biosensors because of their reactive oxygen functional groups and surface defects, which permit the controlled nucleation and growth of metal, metal oxides and semiconductor nanoparticles. Liu et al.63 developed bioconjugate assemblies of various nanoparticles such as AuNPs, AgNPs, PtNPs, PdNPs and latex using the bovine serum albumin (BSA)-based reduction and decoration of GO nanosheets (Fig. 2). The density of AuNPs in the BSA-GO nanocomposite was controlled by adjusting the concentration of BSA protein. Various synthetic approaches, including chemical methods and hydrothermal, electrochemical, and ex situ strategies, have been developed to prepare graphene- and nanoparticle-based nanocomposites by fine tuning the nanoparticle size, shape, distribution, and functionality over graphene, GO and rGO.58
3. Graphene-based electrochemical biosensors
3.1. Glucose biosensors
Diabetes is one of the most common diseases, affecting millions of people worldwide. In 2017, according to the International Diabetes Federation (IDF), 425 million adults were affected by diabetes and this number is expected to rise to 629 million cases of diabetes by 2045.111 The physiological level of blood glucose after a minimum of 8 hours of fasting (pre-meal) determines the prevalence of diabetes; fasting blood glucose level in the 70 to 99 milligrams per deciliter (mg dL−1) (from 3.9 mmol L−1 to 5.4 mmol L−1) range is considered normal, while blood glucose level from 100 mg dL−1 to 125 mg dL−1 (from 5.6 mmol L−1 to 6.9 mmol L−1) is considered prediabetes, and a blood glucose level of 126 mg dL−1 (7.0 mmol L−1) or higher indicates the existence of the diabetes (https://medlineplus.gov/ency/article/003482.htm). The accurate and rapid detection of blood glucose is of critical importance for continuous point-of-care glucose monitoring and clinical diagnosis of diabetes.6 Since the first report of a glucose oxide (GOx)-based enzyme electrode by Clark and Lyons et al.112 for monitoring blood glucose levels, there has been a growing demand for reliable devices for diabetes control; the need for the fabrication of electrochemical biosensors that are capable of label-free real-time monitoring of blood glucose levels with high sensitivity and resolution has been documented in the literature.113
The development of electrochemical glucose sensors to date can be categorized into three generations.114 In the first generation of glucose enzyme electrodes, the measurements relied on the oxygen consumed by the enzyme-catalyzed reaction. Specifically, an enzymatic reaction occurred between glucose and the GOx enzyme electrode in the presence of oxygen, producing hydrogen peroxide (H2O2), and the glucose level was monitored through the amount of enzymatically generated H2O2.115 The second generation witnessed the utilization of electrical mediators to facilitate electron transfer process between the flavin adenine dinucleotide (FAD) active site of GOx and the electrode's surface, a process called mediated electron transfer (MET).115 However, MET-based glucose sensors have several disadvantages; for example, the mediator lowers the total energy of the system and affects the operational stability. Ultimately, third-generation enzymatic biosensors have been developed with no mediator to achieve direct electron transfer (DET) between FAD-GOx and the electrode surface. However, several challenges still exist related to the achievement of DET for accurate and reliable glucose monitoring with operational stability.113 Numerous nanostructured materials have been employed as electrode materials for the fabrication of electrochemical glucose biosensors with greatly enhanced DET processes due to their unique optical and electronic properties.116–119 In particular, carbon nanotubes (CNTs)116,120–123 carbon nanodots (CNDs),117 porous carbon,124 graphene,125 and GQDs126 are preferred as ideal nanostructures for the effective immobilization of enzymes and for the improvement of DET characteristics. Among them, graphene and GO are particularly attractive as promising electrode materials for the immobilization of enzymes and electrochemical glucose biosensing.127,128 Graphene is highly advantageous compared to other materials due to its high specific surface area (2630 m2 g−1 for single-layer graphene), excellent electronic properties and biocompatibility.57,129,130
3.1.1. Surface functionalization
The surface functionalization of graphene often plays a key role in the precise control of the electronic surface states, which could help bringing the detection targets onto the graphene surface through specific molecular interactions and widen its applicability in biosensing.127 The surface functionalization of graphene significantly affects its electrical properties. Moreover, the chemical reduction of GO into rGO with different defect densities, numbers of layers and oxygen concentrations influences the electrochemical behavior and glucose biosensor performance.131 Doping with semiconducting nitrogen (N), boron (B), sulfur (S), fluorine (F) and hydrogen (H) has a profound impact on the physical and chemical properties of graphene, resulting in improved sensitivity.75,132,133
3.1.2. Enzyme immobilization strategies on graphene
The immobilization of enzymes on a solid support is one of the key steps in the fabrication of enzymatic biosensors with high sensitivity, selectivity, stability and confined electron transport between the enzymes and the electrode surface.79 The enzyme immobilization method can affect the enzyme loading, biocatalytic activity and operational stability.134 Different nanostructured materials have been successfully used for the effective immobilization of glucose oxidase (GOx) and their glucose-sensing ability. CNTs and graphene have been extensively studied due to their unique catalytic and electronic properties.135 The high specific surface area and availability of abundant functional groups in graphene and GO make them ideal substrates for modulating enzyme activity and stability.136,137 Different immobilization strategies have been developed for effectively immobilizing enzymes on graphene-based materials.127,138 There are two main approaches for achieving efficient enzyme immobilization: simple physical adsorption (noncovalent) and covalent immobilization.79
3.1.3. Physical adsorption
Noncovalent immobilization on GO or the simple physical adsorption of enzymes on graphene occurs through physical forces such as van der Waals, ionic and hydrophobic interactions. The immobilization procedure consists of simple deposition of the enzyme onto the graphene surface; thus, the sp2-hybridized carbon network is not affected, and the electrical properties of GO are preserved. Specifically, the supramolecular interaction of aromatic molecules can be achieved by the π–π stacking of pyrene derivatives for noncovalent immobilization. However, due to the weak physical interaction between the enzyme and the graphene surface, the electron transfer characteristics, catalytic function and operational stability are highly affected.76
3.1.4. Covalent immobilization
Covalent immobilization can be achieved by modifying GO with different organic linker molecules containing reactive functional groups, which enables the direct covalent conjugation of the enzymes to the GO surface. The covalent immobilization reactions are formed in two main steps. The functionalization of amine groups139,140 and carboxylic groups141,142 on graphene results in covalent bonding between the organic functional groups and the oxygenated groups of GO, which is followed by the conjugation of amine groups of the enzyme with chemically activated amine or carboxylic groups in the second step through bifunctional cross-linker molecules. In general, either 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) or N-hydroxysuccinimide (NHS) is used for carboxylated graphene, while glutaraldehyde is utilized for amino-functionalized graphene.127 The covalent immobilization of the enzyme prevents the inactivation of catalytic functions that might occur in the case of direct physical adsorption and electrically wires the active cofactor of the enzyme to the GO surface. However, covalent immobilization strategies significantly alter the native graphene lattice structure by converting carbon bonding from sp2 to sp3, which markedly decreases the electronic properties of graphene.79 The electroactive enzyme surface density (Γ, mol cm−2) on the modified electrode can be evaluated by:143
Γ = Q/nFA | 1 |
where Q is the charge involved in the reaction (obtained by integrating the anodic peak and dividing by the scan rate), n is the number of transferred electrons (n = 2), F is the Faraday constant, and A represents the geometric area of an electrode.
3.1.5. Graphene-based electrochemical enzymatic glucose biosensors
Enzyme-based electrochemical glucose sensors have attracted significant attention over the past 40 years because of their high selectivity, simplicity, and sensitivity.16 Most of the clinically available systems for monitoring blood glucose levels depend on bioelectrodes based on the glucose oxidase enzyme (GOx).144 Enhanced electrical contact of redox enzymes with the electrode surface is of fundamental interest for the development of mediator-free third-generation electrochemical glucose biosensors with high sensitivity and selectivity.134,145 Depending on the graphene derivative, the conductivity and electrocatalytic activity can differ significantly. For example, the electrical properties of graphene can change upon reduction to GO or rGO as well as upon chemical functionalization.146 Graphene-based materials provide a large specific surface area, excellent electrochemical properties, biocompatibility and plentiful oxygenated functional groups such as hydroxyl, carbonyl, carboxyl and epoxy groups, all of which facilitate the effective immobilization of redox enzymes through either physical adsorption or covalent conjugation for subsequent glucose sensing.79 Graphene-based nanocomposites have been widely used to fabricate enzymatic glucose biosensors, as summarized in Table 1 in terms of their sensitivity, linear detection range and the lowest limit of detection (LOD).147–187
Enzymatic electrochemical glucose biosensors developed from graphene nanocomposite-based electrodes and their sensitivity, concentration range, LOD, and heterogeneous electron transfer rate constant (Ks) between GOx enzyme and the modified graphene electrodesa.
Graphene-based nanocomposites | Linear range | Sensitivity (μA mM−1 cm−2) | Limit of detection (LOD) | K m (mM) | K s (s−1) | Ref. |
---|---|---|---|---|---|---|
GR/CS nanocomposite | 0.08–12 mM | 37.93 | 0.02 mM | — | 2.83 | 147 |
Nf/PdNPs@rGO-APTES//GOx | 3 μM to 4.57 mM | 234.1 | 0.91 μM | — | — | 148 |
GR/AuNPs/CS nanocomposite | 2–10 mM | 0.55 | 180 μM | — | — | 149 |
Sulfonated GR/AuNPs/CS nanocomposite | 0.5–22.2 mM | 6.51 | 0.13 mM | 1.96 | — | 150 |
GR/DNA/AuNPs | 0.8–50 μM | 0.00244 | 0.3 μM | — | — | 151 |
GQDs/GOx | 0.005–1.27 mM | 0.085 | 1.73 μM | 0.76 | 1.12 | 126 |
Reduced carboxyl GR/GOx | 2–18 mM | 7 | 0.02 mM | — | — | 152 |
3D porous GR/GOx | 0.02–3.2 mM | 6.82 | 1.7 μM | — | 6.05 | 153 |
3D porous GR–CS composites | 0.14–7.0 mM | 11.2 | 17.5 μM | — | — | 154 |
rGO/ZnO hybrid | 0.2–6.6 mM | 13.7 | 0.2 μM | 2.2 | 7.55 | 155 |
rGO/ZrO2 NPs | 0.29–14 mM | 11.65 | 0.13 mM | — | 5.03 | 156 |
rGO/PtPd NPs | 2–12 mM | 0.024 | 0.001 mM | — | — | 157 |
rGO/AgNPs | 0.5–12.5 mM | 3.84 | 0.16 mM | — | 5.27 | 158 |
PDDA-capped AuNPs/GR/MWCNTs | 5–175 μM | 29.72 | 4.8 μM | 2.09 | 11.18 | 159 |
GO/AuNPs | 1–8 mM | 0.835 | 10 μM | 0.144 | 5.35 | 160 |
rGO/Fe3O4 NPs | 0.5–12 mM | — | 0.05 mM | — | — | 161 |
rGO/PLL/MnO2 NPs | 0.04–10 mM | 46.36 | 0.02 mM | — | 4.92 | 162 |
GR–CNTs/ZnO hybrid nanostructure | 10 μM to 6.5 mM | 5.36 | 4.5 μM | — | 5.554 | 163 |
MWCNTs/GO nanocomposite | 0.05–23.2 | 0.266 | 28 μM | — | 11.22 | 164 |
Py-NHS ester-modified graphite NPs | 0–2.2 mM | 0.729 | 50 μM | — | — | 165 |
AuNPs/GR/CNTs nanocomposite | 10 μM to 2 mM | 0.695 | 4.1 μM | 10.5 | 3.36 | 166 |
Au-MWCNTs–GR hybrid composite | 50 μM to 20 mM | — | 2.48 μM | 1.07 | — | 167 |
3D GR/CNTs hybrid | 2–8 mM | 19.31 | 0.5 mM | — | 9.0 | 168 |
Pt nanospheres/flexible GR sheets | 10 μM to 10 mM | 150.8 | 1 μM | — | — | 169 |
CS-rGO-AuNPs hybrids | 15 μM to 2.13 mM | 102.4 | 1.7 μM | 4.33 | — | 170 |
Fe3O4 NPs/CS-GR | Up to 26 mM | 5658 | 16 μM | — | — | 171 |
rGO-activated carbon/PtNPs | 0.002–10 mM | — | 2 μM | — | — | 172 |
rGO/β-cyclodextrin composite | 50 μM to 3.0 mM | 59.74 | 59.74 μM | 1.78 | 3.8 | 173 |
rGO/C60 composite | 0.1–12.5 mM | 55.97 | 35 μM | 4.4 | 2.92 | 174 |
AuNPs/GO nanocomposites | 0.3–20 mM | 42 | 0.3 mM | — | 8.3 | 175 |
GR/Cu nanocubes | 25 μM to 4 mM | 5432.2 | 250 nM | — | — | 176 |
rGO/GOx | 0.1–1 mM | 9.60 | 5.8 μM | — | — | 177 |
rGO/GOx | 1.4 and 9.5 mM | 2.47 | 13.4 μM | — | — | 178 |
GR/polyethyleneimine-AuNPs hybrid | 1–100 μM | 93 | 0.32 μM | — | 5.4 | 125 |
PANI-modified SnO2/rGO | 0.1 nM to 5 μM | 96.1 | 0.26 nM | — | — | 179 |
MnO2/GR composite | 0.04–2 mM | 3.3 | 10 μM | — | 2.57 | 180 |
rGO/polyethyleneimine (PEI) | 0.01 μM to 15.5 mM | 0.00334 | 5 μM | 4.09 | — | 181 |
CVD-grown GR | 0.2–9.8 mM | 0.087 | 0.12 μM | — | — | 182 |
Fe3O4/rGO nanocomposite | 0.05–1 mM | 5.9 | 0.1 μM | 0.16 | 13.78 | 183 |
PAA-rGO/VS-PANI/LuPc2/GOx | 2–12 mM | 15.31 | 25 μM | 17.05 | — | 201 |
Fc-CS/SWNTs/GOD/3DGR foam | 5.0 μM to 19.8 mM | — | 1.2 μM | — | — | 184 |
rGO/Fe3O4 nanocomposite | 0.5–10 mM | 2.645 | 106.5 μM | — | 2.03 | 185 |
AuNPs/rGO | 2–10 mM | 18.73 | 0.9 nM | 2.63 | 2.51 | 186 |
PtNPs/rGO | 2–10 mM | 27.51 | 1.21 μM | 3.43 | 3.05 | 187 |
Abbreviations used: APTES: (3-aminopropyl)triethoxysilane, PEDOT: poly(3,4-ethylenedioxythiophene), PAA: polyacrylic acid, PEI: polyethyleneimine, PANI: polyaniline, VS-PANI: vinyl-substituted polyaniline, MWCNTs: multiwalled carbon nanotubes, CS: chitosan, Nf: Nafion, QDs: quantum dots. PDDA: poly(diallyldimethylammonium chloride), Py-NHS: 1-pyrenebutyric acid N-hydroxysuccinimide ester. LuPc2: lutetium phthalocyanine, Fc: ferrocene.
An example of the enzymatic glucose biosensor is discussed here. Qi et al.175 used AuNPs decorated GO nanosheet for developing a glucose sensor by attaching AuNPs on to the surface of GO nanosheet via a benzene (Ph) bridge employing aryldiazonium salt chemistry. The schematic biosensor fabrication process is depicted in Fig. 3. GO-Ph-AuNPs nanocomposite was attached to 4-aminophenyl modified glassy carbon electrode (GCE). Thereafter, the GCE/GO-Ph-AuNPs nanocomposite was functionalized with 4-carboxyphenyl (CP) and GOx was covalently attached to form the GCE/GO-Ph-AuNPs-CP/GOx based glucose sensor. The sensor showed a linear range of 0.3–20 mM, and sensitivity of 42 μA mM−1 cm−2 for glucose detection as well as fast electron transfer and enzyme turnover rates of 8.3 and 112/s, respectively. The GCE/GO-Ph-AuNPs-CP/GOx sensor also exhibited a high selectivity toward glucose detection because almost no amperometric current was noticed for 100 mM of dopamine (DA), ascorbic acid (AA), uric acid (UA), acetaminophen (AP), fructose, lactose, and galactose interfering analytes compared to 10 mM of glucose concentration. The GCE/GO-Ph-AuNP-CP/GOx-based sensor was also used to detect in real time the glucose changes occurring during growth of two cell lines, where glucose uptake rate of 8.8 fmol per min per cell for human umbilical vein endothelial cells (HUVECs) and 15.5 fmol per min per cell for human cervical cancer HeLa cell lines was measured. The GCE/GO-Ph-AuNP-CP/GOx sensor showed long-term stability by retaining 90.3% initial current density after 10 days storage at 4 °C due to the strongly entrapped GOx on AuNPs and covalent bonding between the sensor interfaces.
3.1.6. Direct electron transfer (DET)
Accomplishing DET in amperometric glucose biosensors is of significant interest for the fabrication of third-generation electrochemical biosensors without mediators. The direct electrical wiring of immobilized GOx enables the detection of glucose at low potentials that are little more positive than the redox potential of GOx.188 Significant work has been performed on the effective immobilization of the GOx enzyme on graphene-based materials for the development of highly sensitive enzymatic glucose biosensors with DET characteristics.74,152,153 However, establishing efficient DET between the biocatalyst and the electrode surface is a key challenge that arises due to the large and complex structure of the GOx enzyme; with the FAD redox active center deeply embedded within the protein, accomplishing DET is challenging.189 The location of the active site FAD within the GOx structure creates a high electron tunneling distance between the electron donor (FAD) and the electrode surface, thus significantly limiting the electron transfer rate. Efficient electrical communication between the redox enzyme and the electrode surface significantly minimizes the electron tunneling distance, leading to highly enhanced biosensor sensitivity.168 Liang et al.190 demonstrated the challenge associated with the DET process in GOx-immobilized GR electrodes with and without mediators for sensing glucose, as shown in Fig. 4A. The corresponding cyclic voltammograms (CVs) of the GCE are shown in Fig. 4B. A pair of well-defined redox peaks at −0.48 V with a 40 mV separation of peak potential is associated with the redox potential of FAD-GOx on the modified electrode surface; however, no redox peaks are observed when GOx is directly adsorbed onto the bare GCE, indicating that the rGO/GOx-modified GCE can promote DET, which occurs primarily via contact between the rGO and FAD/GOx. They observed that DET and the catalytic activity of GOx cannot occur simultaneously.
The DET process between FAD-GOx and GO can be described as follows:
d-glucose + GOx(FAD) → d-glucono-1,5-lactone + GOx(FADH2), | 2 |
GOx(FADH2) ↔ GOx(FAD) + 2H+ + 2e− | 3 |
where FAD and FADH2 are the oxidized and reduced forms of the redox center of the GOx enzyme. GOx is a homodimer containing its cofactor bound to its two identical 80-kDa subunits, which can easily undergo enzymatic reactions. FAD is an electroactive center that exhibits a two-electron and two-proton redox reaction, such as GOx(FAD) + 2H++2e− ↔ GOx(FADH2). Glucose, when added, is oxidized by the GOx enzyme into d-glucono-1-5-lactone and GOx (FADH2) by the transfer of two electrons and two protons to FAD-GOx. If FADH2 can be oxidized back to FAD without any electrochemical mediators or oxygen, then the process is referred to as DET.118 The rate constant of the electron transfer (Ks) between the GOx- and GO-modified electrodes was calculated using the Laviron equation.191
log Ks = α log(1 − α) + (1 − α)log α − log(RT/nFv) − α(1 − α)nFΔEp/2.3 | 4 |
where α is the charge transfer coefficient, R is the gas constant (8.314 J mol−1 K−1), T is the room temperature, ΔEp is the peak separation of the FAD/FADH2 redox couple, and n is the number of electrons transferred (n = 2).
Considerable efforts have been made to overcome the limitation of long electron tunneling distances and accomplish DET between the immobilized enzyme and the electrode surface. Among different nanostructured materials, GR has been extensively investigated for DET characteristics and glucose-sensing performance.141,192 For example, Wang et al.140 showed a direct electrochemical reduction of single-layer GO and subsequent functionalization with (3-aminopropyl)triethoxysilane (APTES) for covalent immobilization with GOx and application of developed GCE-APTES-rGO-GOx electrode in glucose sensing with a linear range of 0 to 24 mM. Additionally, Guler et al.193 fabricated a glucose sensor by immobilizing GOx onto APTES-functionalized rGO deposited on GCE. The functionalization of APTES provides an –NH2-terminated surface, which enables covalent conjugation of the –NH2 groups of GOx via bifunctional cross-linker glutaraldehyde (GA) molecules. The enzymatic glucose biosensor also consisted of the Nafion (Nf) protective membrane. The Nf/rGO-APTES/GOx/GCE composite-based based biosensor showed the sensitivity of 75.26 μA mM−1 cm−2 and 124.87 μA mM−1 cm−2, a wide linear range of 0.02–4.34 mM and 0.05–15.25 mM with LOD values of 9 μM and 0.017 mM for glucose and H2O2 detection, respectively. Unnikrishnan et al.194 demonstrated a simple one-step immobilization of GOx onto rGO and subsequent glucose sensing. The resulting rGO-GOx-GCE sensor exhibited DET characteristics with a sensitivity of 1.85 μA mM−1 cm−2 and a linear range of 0.1–27 mM. Osikoya et al.182 used CVD-grown graphene to construct an electrochemical biosensor that displayed electrocatalytic activities and exhibited a linear response from 0.2 to 9.8 mM with a sensitivity of 0.087 μA μM−1 cm−2 and an LOD of 0.12 μM. Ravenna et al.195 reported a glucose sensor using rGO films with adsorbed phenothiazone to study electron transfer process between the FAD-dependent glucose dehydrogenase and the used electrodes. The DET results showed sensitivity of 42 mA M−1 cm−2 and a linear range of 0.5–12 mM for glucose detection as well as high selectivity against different interfering analytes. Liu et al.196 reported the fabrication of a GR-GOx enzyme electrode by the alternate layer-by-layer (LBL) self-assembly of GOx over single-layer or multilayer graphene through noncovalent π–π stacking interactions, as shown in Fig. 5. Each pyrene-functionalized GOx enzyme contained 5.4 pyrene functional groups and maintained over 76% of the biocatalytic activity of GOx. The graphene-bridged GOx enzyme electrode-based biosensor showed a linear range between 0.2 and 40 mM and an LOD as low as 0.154 mM for glucose sensing. The sensitivity towards glucose increased with increasing layers of graphene and GOx but was insignificant at 4 enzyme layers. The GOx enzyme electrode showed a very low response after adding 0.2 mM of ascorbic acid and uric acid, and also retained 82.2% biocatalytic activity after 4 weeks of storage at 4 °C.
The chemical reduction of GO into rGO with different amounts of defect density, layers and oxygen concentrations influences the electrochemical behavior and the glucose sensor performance.131 Chemical doping with foreign atoms is a promising approach to intrinsically tune the electrical properties and regulate electron transport to influence glucose sensor performance.133 Wang et al.133 demonstrated that a glucose sensor using N-doped graphene that exhibited strong electrochemical activity and fast DET kinetics of GOx with a linear range of 0.1–1.1 mM and LOD of 0.01 mM. The enhanced performance of the biosensor is due to the high electronic state density and the plenty of free electrons available in N-doped GR, which facilitates H2O2 electrochemical reduction by breaking of the O–O bond in H2O2. Nitrogen doping modifies the density of states around the Fermi level of graphene, which considerably enhances the electron transfer rate. Liang et al.152 reported the DET of self-assembled GOx on the surface of electrochemically reduced carboxyl graphene on a GC electrode. Their biosensor showed distinct and quasi-reversible redox peaks at a potential of −0.467 V, promoting DET process with an improved linear range from 2–18 mM and a low LOD of 0.02 mM.
The direct electrochemistry of GOx immobilized on three-dimensional (3D) porous graphene-modified electrodes and the effect of graphene defect structure on glucose sensor performance were studied.153,197 Guo et al.198 fabricated an enzymatic glucose biosensor using highly conductive N-doped CVD-grown graphene (3D N-GR). The GOx enzyme was effectively immobilized on 3D N-GR using a chitosan (CS) biopolymer via molecular binding with NH2 groups. The fabricated 3D N-GR–CS-GOx biosensor showed a sensitivity of 226.24 μA mM−1 m−2 and a linear range of 0.1–1.3 mM due to the high conductivity and porosity of the N-GR network, providing a large surface area for GOx enzyme loading and improving electron transport. Furthermore, Razmi et al.126 demonstrated GQDs as an effective matrix for the immobilization of GOx on carbon ceramic electrode (CCE); the resulting GOx-GQD-CCE sensor showed high surface loading and strong affinity to enzymes while promoting DET, showing sensitivity of 0.085 μA μM−1 cm−2 and a wide linear range of 5–1270 μM with an LOD of 1.73 μM for glucose detection. Manoj et al.199 demonstrated a biosensor using an aldehyde-functionalized ionic liquid (CHO-IL) and 3-(3-formyl-4-hydroxybenzyl)-3-methylimidazolium hexafluorophosphate, as a platform for covalent immobilization (Fig. 6). Specifically, CHO-IL was immobilized on electrochemically reduced GO (EC-rGO) using the π–π stacking of imidazolium and hydroxybenzyl groups with EC-rGO, which permitted the covalent bonding of Azure A mediator or GOx enzyme. The Azure A-immobilized biosensor showed a linear range of 0.03–1 mM, an LOD of 11.5 μM and sensitivity of 133.2 μA mM−1 cm−2 for nonenzymatic detection of H2O2. The GOx-immobilized CHO-IL biosensor exhibited an improved sensing response with a sensitivity of 17.7 μA mM−1 cm−2, a broad linear range of 0.05–2.4 mM and an LOD of 17 μM for glucose detection.
3.1.7. Graphene/polymer composite-based glucose biosensors
To enhance the catalytic function of immobilized GOx and the operational stability of the biosensor, GO is grafted with different polymers, such as polyethylene glycol (PEG),137 polyvinylpyrrolidone (PVP),192 or biopolymers, such as chitosan (CS).154 The polymer presents functional groups on the GO surface that enable the effective immobilization of redox enzymes without losing their biological functions and increase operational stability by suppressing leaching effects, while GO permits effective electron transport for enzymatic sensors.19,80 Kang et al.147 showed that a GR–chitosan (GR–CS) nanocomposite electrode is capable of high loading capacity (1.12 × 10−9 mol cm−2) for the immobilization of GOx enzyme, which exhibits DET with sensitivity of 37.9 μA mM−1 cm−2, a linear range of 0.08 to 12 mM and an LOD of 0.02 mM. The CS biopolymer possesses amino (–NH3/NH2) and hydroxyl (–OH) functional groups, which facilitate the immobilizations of GOx while sustaining the biocatalytic functions and stabilizing the GOx enzymes. Similarly, Liu et al.141 reported the covalent immobilization of GOx enzymes on the carboxyl acid (–COOH) groups of GO via amide bonds in the presence of EDC and NHS. Their GO/GOx composite glucose biosensor showed sensitivity of 8.045 mA M−1 cm−2, a broad linear range and exhibited biocompatibility with human retinal pigment epithelium cells. Bharath et al.200 showed mesoporous 1D hydroxyapatite (HAp) nanorods on rGO for the efficient immobilization of GOx enzyme, displaying a highly enhanced electron transfer rate of rGO-HAp-GOx-GCE sensor with a superior sensitivity of 16.9 μA mM−1 cm−2, a linear range of 0.1–11.5 mM and an LOD of 0.03 mM. Liu et al.184 showed a facile, one-step chitosan (CS)-based electrodeposition strategy for the fabrication of enzymatic glucose biosensors. The sensor was fabricated by electrodepositing a ferrocene (Fc)-functionalized CS hybrid (Fc-CS) and a single-walled carbon nanotube (SWCNT) solution to form a homogeneous film with GOx enzymes. Fc-CS/SWCNT/GOx was immobilized via electrodeposition process on the surface of 3D graphene foam (GF) (Fig. 7A). The porous 3D structure is shown in Fig. 7B. Because of the superior properties of 3D GF, such as a large active surface area, high conductivity and fast mass transport dynamics, this sensor exhibited a wide linear range from 5.0 μM to 19.8 mM, an LOD of 1.2 μM and a fast response (95% response within 8 s) for the detection of glucose (Fig. 7C and D). Al-Sagur et al.201 demonstrated a highly sensitive enzymatic glucose biosensor based on lutetium phthalocyanine (LuPc2) as a redox mediator in rGO, integrated with polyacrylic acid (PAA) in vinyl-substituted polyaniline (VS-PANI) multifunctional hydrogels. The fabricated PAA-rGO/VS-PANI/LuPc2/GOx biosensor showed a response time of 1 s, sensitivity of 15.31 μA mM−1 cm−2 in a linear range of 2–12 mM with an LOD of 25 μM for glucose detection and 3 month long storage stability.
3.1.8. Graphene/nanoparticles (NPs) hybrid-based glucose sensors
The integration of graphene with inorganic nanoparticles has drawn significant interest in the development of hybrid nanostructures for electrochemical glucose sensors.57,58,202 Integrating electrocatalytically active metal nanoparticles onto highly conductive GR surfaces is attractive for electrode fabrication because of the large accessible surface area, electrical conductivity and capacity for immobilizing enzymes.203 Furthermore, chemically derived graphene contains a large number of defects/vacancies and possesses functional groups such as carbonyls, epoxides, and hydroxyls, thus serving as a highly suitable matrix for the immobilization of inorganic nanoparticles as well as enzymes with enhanced stability and higher loading capacity.188 The hybrid GO/inorganic metal nanocomposites are primarily formed by decorating GO nanosheets with inorganic metal nanoparticles including AuNPs,149,159 AgNPs,158 PtNPs,172,204 PdNPs,205 CuNPs206 and RuNPs, metal oxide nanoparticles (ZnO,163,207,208 CuO,209 ZrO2,156 SnO2, NiO,210 MnO2,162 Fe3O4 (ref. 211 and 212)), bimetallic nanoparticles (Pt/Pt NPs,157), and metal/metal oxide composites (AuWO3 (ref. 213)). The surface functionalization of these supported NPs provides an effective approach for the site-specific conjugation of biomolecules without loss of activity. In particular, the integration of Au nanoparticles with the GOx enzyme can provide site-specific conjugation of the FAD site and improve the specific surface area, thus minimizing the electron tunneling distance to facilitate DET.214 Willner et al.215,216 reported the functionalization of AuNPs to create an FAD-active center of GOx for electrochemical enzymatic biosensors.
Graphene/nanoparticle composite-based electrochemical enzymatic glucose biosensors have been summarized in Table 1. Noble metal nanoparticles (Au, Ag, Pt, and Pd) are widely used for the effective site-specific conjugation of enzymes.160,217 Palanisamy et al.158 developed a biosensor by immobilizing GOx on an EC-rGO/AgNP nanocomposite. The biosensor showed a pair of distinct redox peaks having a formal potential (E°) of −0.422 V and a heterogeneous electron transfer rate constant (Ks) of 5.27 s−1, suggesting a high affinity between GOx and the EC-rGO/AgNP nanocomposite and fast DET. The biosensor exhibited high sensitivity toward glucose detection in the 0.5 to 12.5 mM concentration range with an LOD of 0.16 mM. Claussen et al.218 demonstrated a biosensor with PtNPs decorated on multilayered graphene petal nanosheets (MGPNs). The performance of biosensor was optimized through electrodeposited PtNPs by changing their size and morphology. The designed GOx-PEDOT/PtNP/MGPN biosensor demonstrated a wide linear range of 0.01–50 mM with an LOD of 0.3 μM for glucose detection and a stable shelf-life by retaining 75% sensitivity over a time period of 5 week.
An enzymatic glucose biosensor based on the tannic acid (TA)-mediated deposition of AuNPs onto rGO nanocomposites was demonstrated by Çakıroğlu and Özacar.186 The fabricated glucose biosensor exhibited a sensitivity of 18.73 mA mM−1 cm−2 and a linear range of 2–10 mM. Akkaya et al.187 also fabricated a glucose biosensor based on the direct electrochemistry of GOx on PtNPs supported on a TA-rGO nanocomposite, as shown in Fig. 8A. Specifically, after the electrochemical oxidation of tannic acid to quinone, the formation of π–π interactions between GO and TA and of Schiff-base supported hydrogen bonding between GOx and TA that improved DET. The curves from CV measurements in PBS (0.05 M, pH 7.4) solution at 100 mV s−1 scan rate are shown in Fig. 8B. The GOx/PtNPs/rGO-GC-modified electrode exhibited redox peaks at a formal potential (E°) of −0.462 V and the peak-to-peak separation (ΔEp) of 56 mV, indicating the fast electron transfer between PtNPs/rGO nanocomposite and GOx. The redox peak current linearly decreased as the concentration of glucose was increased (Fig. 8C). By adding glucose, more GOx(FAD) was transformed into GOx(FADH2) due to the biocatalytic reaction. The fabricated biosensor showed an enhanced sensitivity of 27.51 μA mM−1 cm−2, a wide linear range of 2–10 mM and an LOD of 1.21 μM. Notably, the sensitivity of the rGO/PtNP/GOx-GCE electrode is higher than that of the rGO/AuNP/GOx-based biosensor (18.73 μA mM−1 cm−2),186 which can be ascribed to the high catalytic activity of the PtNPs supported on the surface of rGO.
Bimetallic nanoparticles are well known to exhibit highly enhanced electrochemical activity compared to monometallic nanoparticles.219 Taking advantage of this property, Hossain and Park157 designed a glucose biosensor based on the immobilization of GOx on rGO modified with electrochemically deposited PtPdNPs. The resulting biosensor showed sensitivity of 24 μA mM−1 cm−2, a linear range of 2–12 mM, an LOD of 0.001 mM, and a fast response time of 5 s. In addition, metal oxide nanoparticles or magnetic nanoparticles supported on graphene have been widely used to develop electrochemical enzymatic glucose biosensors (Table 1). Liu et al.180 reported an enzymatic glucose sensor based on a composite of MnO2 NPs supported on graphene. The GR-MnO2NPs-GOx-Nafion based sensor exhibited a high sensitivity of 3.30 μA mM−1 cm−2, a wide linear range of 0.04 to 2 mM with an LOD of 10 μM. The sensor displayed high selectivity for the determination of glucose level in the presence of interfering bioanalytes including AA and UA which may be associated with the use of Nafion in the modified electrode. Vilian et al.156 fabricated a glucose biosensor using GOx immobilized in a poly(l-lysine) (PLL) and rGO-zirconium oxide (rGO-ZrO2) nanocomposite. The sensor exhibited DET by displaying well-defined redox peaks at the formal potential (E°) of −0.403 V with a small peak-to-peak separation (ΔEp = 27 mV). The GOx-PLL/rGO-ZrO2 based sensor exhibited a sensitivity of 11.65 μA mM−1 cm−2, a linear range of 0.29–14 mM and LOD of 0.13 mM. The biosensor showed recoveries of 97% to 102.5% in the spiked samples of human urine for glucose detection and 94.4% retention of original response after storing at 4 °C for a period of 1 month. Zhao et al.208 reported a long-range electrical wiring of GOx using a ZnO nanorods/EC-reduced graphene heterostructure. The glucose biosensor fabricated by immobilizing GOx on ZnONRs/EC-reduced graphene enabled contact with enzymes through the ZnO nanorods. The charge transfer was associated with ZnO nanorods between the redox center of FAD-GOx and the electrode. The fabricated GOx-ZnONRs/EC-reduced graphene/PT-based glucose biosensor showed DET characteristics with a sensitivity of 89.84 μA mM−1 cm−2 and a linear response to glucose concentrations of 0.2–1.6 mM with a correlation coefficient (R) value of 0.998. The Ks value of 0.92 s−1 indicated DET of GOx. Teymourian et al.161 fabricated a glucose biosensor based on a Fe3O4/rGO-modified GCE, which showed glucose sensing with a wide linear range of 0.5 mM to 12 mM and an LOD of 0.05 μM.
3.1.9. Graphene-based nonenzymatic glucose biosensors
The enzymatic glucose sensor exhibits high sensitivity and selectivity because of the superior catalytic functions of the enzymes. However, the catalytic function of enzymes such as GOx can be negatively influenced by many parameters, including pH, temperature, pressure and humidity.220 In addition, the sensor performance and operational stability depend strongly on the immobilization method, biocatalytic functions of the enzyme, and DET characteristics, which greatly limit their practical applications. Although GOx is relatively stable compared to other enzymes, it quickly loses its activity below pH 2.0 and above pH 8.220 Moreover, it has an apparent transition temperature of 55.8 ± 1.28 °C and an activation energy of 280 kJ mol−1.221 Thus, GOx undergoes structural transformations and exhibits damage above 40 °C. Therefore, the development of a low-cost, sensitive, enzyme-free approach to glucose detection is a desirable alternative to enzymatic methods. Nevertheless, given the sensitivity and selectivity of the commercially available glucose sensor strips, nonenzymatic methods have to meet stringent requirements for commercial viability.222
The unique electrochemical properties of graphene and its derivatives have also been applied to fabricate nonenzymatic glucose biosensors. Moreover, supporting inorganic nanoparticles on graphene allows significant enhancement of their electrocatalytic activity and sensing performance.223 Due to their strong electrocatalytic activity, noble metal nanoparticles have been decorated/supported on graphene to construct highly sensitive enzyme-less electrochemical glucose sensors.223Table 2 summarizes the performance of nonenzymatic electrochemical glucose biosensing developed from graphene-based nanocomposites with a very wide variety of metal nanoparticles/nanostructures.210,224–280 For example, Deepalakshmi et al.224 used nitrogen-doped graphene (N-GR)-encapsulated nickel cobalt nitride (NiCo2N) core–shell nanostructures for nonenzymatic detection of glucose and hydrogen peroxide. The synergistic effect of the NiCo2N/N-GR core–shell nanostructures resulted in high sensitivity and selectivity. NiCo2N/N-GR/GCE sensor detected 1.09-mM glucose concentration in human blood serum with 94.8% recovery, showed high selectivity for glucose detection against interfering biomolecules such as DA, UA, AA, lactic acid, fructose, lactose and NaCl, as well as long-term environmental stability for glucose oxidation by retaining 92.31% of initial current response after 45 days at room temperature. Hoa et al.225 used Pt nanoparticles supported on GO hydrogel (GOH) for nonenzymatic glucose detection. The PtNPs/GOH sensor showed a sensitivity of 137.4 μA mM−1 cm−2, which is 7-times greater than in the absence of PtNPs on GOH. In addition, the sensor showed selective detection in real blood samples and good anti-interference ability toward AA, UA, and DA interferents. Jiang et al.226 prepared nitrogen-doped graphene (N-GR) decorated with copper nanoparticles (CuNPs) through simple thermal treatment for nonenzymatic glucose detection. The CuNPs/N-GR sensor showed greatly enhanced glucose-sensing performance with a sensitivity of 48.13 μA mM−1, a linear range of 0.004–4.5 mM, an LOD of 1.3 μM, and the response time of <5 s. The peak current of glucose oxidation was found to be approximately 23 times greater compared with pristine CuNPs. Ju et al.227 demonstrated an enhanced nonenzymatic amperometric glucose biosensor based on rGO decorated with copper nanowires (CuNWs). The resulting sensor displayed enhanced sensitivity and LOD, which was attributed to the higher catalytic activity and electrical conductivity of the CuNWs. The sensitivity was found to be 1625 μA cm−2 mM−1 with a linear range up to 11 mM, an LOD of 0.02 μM and a fast response time of <2 s at a potential of 0.58 V. Moreover, the sensor exhibited negligible interference from AA, DA, UA, acetamidophenol and other carbohydrates. Gowthaman et al.228 reported a nonenzymatic glucose biosensor based on a Cu nanostructure-deposited nitrogen-doped graphene (N-GR). Owing to the unique dendritic nanostructure of Cu on N-GR, the sensor exhibited 2-times greater glucose oxidation current than that of pristine N-GR, with a sensitivity of 1848 μA mM−1 cm−2, a linear range of 0.0005–5.0 mM, and an LOD of 0.014 μM. The biosensor showed high selectivity toward glucose determination against interfering bioanalytes including Na+, K+, Mg2+, Ca2+, Cl−, SO42−, urea, oxalic acid, AA and UA. The recoveries of 97.34 to 99.52% and 97.19 to 98.01% in spiked human blood serum and urine samples were achieved for the determination of glucose. Bimetallic nanoparticles supported on GO have also been widely employed to enhance the electrocatalytic activity and sensitivity of glucose biosensors. Gao et al.229 used sonication-assisted electrochemical synthesis to prepare bimetallic PtNiNPs/GR nanocomposite for nonenzymatic glucose detection (Fig. 9). The PtNiNPs are found to be uniformly distributed and supported on graphene surfaces compared with SWCNTs. The biosensor displayed a wide linear range of 0.5–35 mM, LOD of 10 μM, and a sensitivity of 20.42 μA mM−1 cm−2 with a negative potential of −0.35 V. The PtNiNPs/ERGO/GCE sensor also showed high selectivity for the determination of glucose against interfering bioanalytes including AA, UA, urea, AAP, and fructose, and recoveries of 91.3% to 108.2% for glucose detection in human urine samples. Sheng et al.230 reported a NiCoNPs/polypyrrole/rGO nanocomposite for nonenzymatic glucose sensing. The designed nonenzymatic glucose sensor displayed a sensitivity of 153.5 μA mM−1 cm−2, a wide linear range of 0.5 μM to 4.1 mM, and an LOD of 0.17 μM for the glucose detection.
Graphene/nanoparticles (NPs) nanocomposite-based nonenzymatic glucose biosensors and their sensitivity, concentration detection range and LODa.
Graphene-based nanocomposites | Linear range | Sensitivity (μA mM−1 cm−2) | Limit of detection | Ref. |
---|---|---|---|---|
NiCo2N/N-GR core–shell | 2.008 μM to 7.15 mM | 1803 | 50 nM | 224 |
GR/PtNiNPs | 0.5–35 mM | 20.42 | 10 μM | 229 |
GR/CuO NPs nanocomposites | 1 μM to 8 mM | 1065 | 1 μM | 231 |
3D GF/cobalt oxide nanowires (Co3O4NWs) composite | Up to 80 μM | 3390 | 25 nM | 232 |
GR–cobalt oxide nanoneedles | 0.2–3 mM | — | 10 μM | 233 |
GR paper/PtAu–MnO2 nanocomposites | 0.1–30.0 mM | 58.54 | 0.02 mM | 234 |
GO/NiONPs composite | 3.13 μM to 3.05 mM | 1087 | 1 μM | 210 |
GO/CuONPs composite | 2.79 μM to 2.03 mM | 262.52 | 0.69 μM | 209 |
GR/Cu2O nanocubes | 0.3–3.3 mM | — | 3.3 μM | 235 |
Cu–GR nanoflowers | 5–900 μM | 11.3 | 1 μM | 236 |
Pt nanoflowers/GO composite | 2–20.3 mM | 0.64 | 2.0 μM | 237 |
Mn3O4/3D GR foam | 0.1–8 mM | 360 | 10 μM | 238 |
rGO/CuO nanoflowers/Pt nanocubes | Up to 12 mM | 3577 | 0.01 μM | 239 |
N-doped GR/CuNPs composite | 0.004–4.5 mM | 48.13 | 1.3 μM | 226 |
rGO/Ni(OH)2 nanostructures | 15 μM to 30 mM | 11.4 | 15 μM | 240 |
PtPd-IL-rGO nanocomposite | 0.1–22 mM | 1.47 | 2 μM | 241 |
Ni(OH)2/3D GF | 1 μM to 1.17 mM | 2.65 | 0.34 μM | 242 |
GR/PtNi NPs | 0.5–20 mM | 30.3 | 2 μM | 243 |
Cu2O NPs/graphene | 0.5 μM to 2 mM | 2939.24 | 0.09 μM | 244 |
PdCu NPs/3D GR hydrogel | 2–18 mM | 48.0 | 0–8 mM | 245 |
GO nanoribbon/AuNPs hybrid | 0.5 M to 10 mM | 59.1 | 5 μM | 246 |
Ni(OH)2/rGO/MWCNTs | 10–1500 μM | 2042 | 2.7 μM | 247 |
SnO2/rGO composite | 50–500 μM | 1930 | 13.35 μM | 248 |
PVP/GNs/NiNPs/CS composite | 0.1 μM to 0.5 mM | 103.8 | 30 nM | 249 |
rGO/Au–CuO NPs | 1 μM to 12 mM | 2356 | 0.01 μM | 250 |
AuNPs/Ni–Al double hydroxide/SWCNTs/GR composite | 10 μM to 6.1 mM | 1989 | 1 μM | 251 |
S-GR/CuO NPs composite | 0.1–10.5 mM | 1298.6 | 80 nM | 252 |
N-rGO/Mn3O4 NPs | 1.0–329.5 μM | 0.026 | 0.5 μM | 253 |
CuNiO/GO | 0.05–6.9 mM | 225.75 | 16 μM | 254 |
GR/Pt nanoclusters/PVP composite | 1–25 mM | 1.21 | 30 μM | 255 |
GO/Cu NPs | Up to 12 mM | 447.65 | 3.4 μM | 256 |
rGO/Pt–NiO nanoplate arrays | 0.008–14.5 mM | 832.95 | 2.67 μM | 257 |
Needlelike NiCo2O4/3D GF | 0.5 μM to 0.59 mM | 2524 | 0.38 μM | 258 |
rGO nanosheet/Cu nanowires composite | 1 μM to 11 mM | 1625 | 0.2 μM | 227 |
NiO NPs/polyaniline nanowire/GO composite | 2 μM to 5.560 mM | 376.22 | 0.5 μM | 259 |
NiCo alloys/polypyrrole/rGO nanocomposites | 0.5 μM to 4.1 mM | 153.5 | 0.17 μM | 230 |
Cu2O/AlOOH/rGO nanocomposite | 5.0 μM to 14.77 mM | 155.1 | 2.6 μM | 260 |
NiCo2O4 nanowrinkles/rGO | 0.005–8.6 mM | 548.9 | 2 μM | 261 |
Cu NPs/pencil graphite | 1.0–100 mM | 1467.5 | 0.44 μM | 262 |
CuCo2O4 nanosheets/graphite paper | Up to 320 μM | 3.625 | 5 μM | 263 |
AgPt/rGO composite | 0.003–7.72 mM | 129.32 | 1.8 μM | 264 |
Hollow CuCo2O4/porous rGO composite | 0.5–3354 μM | 2426 | 0.15 μM | 265 |
GQD/CoNiAl-layered double hydroxide | 0.01–14.0 mM | 48.717 | 6 μM | 266 |
GR/BiOCl nanohybrid | 0.5–10 mM | 1.878 | 0.22 mM | 267 |
AuNPs/N-doped GR | 0.04–16.1 mM | 0.25 | 12 μM | 268 |
CuS NPs/rGO | 0.0001–3.88 mM | 429.4 | 32 nM | 269 |
NiCo2O4/nitrogen-doped rGO/IL composite | 0.001–4.555 mM | 3760 | 0.18 μM | 270 |
CuNPs/EC-rGO composite | 0.14–5091 mM | 445 | 0.049 μM | 271 |
N-doped GR/Cu nanostructures composite | 0.0005–5.0 mM | 1848 | 0.014 μM | 228 |
Honeycomb-like CoNS/RGO/PPy nanocomposite | 0.5 μM to 2.667 mM | 297.73 | 29 nM | 272 |
3D GR/Ni on ZnO nanorod arrays | 0.05 μM to 1.11 mM | 2030 | 0.15 μM | 273 |
Nanoneedle like CuO/N-doped rGO | 0.5–639 μM | 0.0034 | 0.01 μM | 274 |
Ni plasma-modified GR | 1–1150 μM | 2213 | 1 μM | 275 |
rGO/CuS NF nanocomposite | 1–2000 μM | 53.5 | 0.19 μM | 276 |
3D Cu–Co/rGO nanocomposite | 1 μM to 4 mM | 240 | 0.15 μM | 277 |
GNs/GR nanoribbons/NiNPs | 5 nM to 5 mM | 2300 | 2.5 nM | 278 |
CuNPs/rGO core–shell nanocomposite | 0.001–2 mM | 150 | 0.34 μM | 279 |
NiO/PtNPs/EC-rGO composite | 0.05–5.66 mM | 668.2 | 0.2 μM | 280 |
Abbreviations used: PVP: polyvinyl-pyrrolidone, EC-rGO: electrochemically reduced graphene oxide, GF: graphene foam, BiOCl: bismuth oxychloride, CuSNFs: copper sulfide nanoflake.
In addition to metal/graphene hybrid nanostructures, copper (Cu), and nickel (Ni) oxide nanostructures have been widely studied in the development of nonenzymatic electrochemical glucose sensors due to their high electrochemical activity and stability. Song et al.209 demonstrated a non-enzymatic glucose biosensor based on CuO nanoparticles (CuONPs) supported on GO nanosheet with a high sensitivity of 262.52 μA mM−1 cm−2 and a wide linear range between 2.79 μM and 2.03 mM with an LOD of 0.69 μM under 0.7 V detection potential. In the real human serum, the CuONPs/GO sensor also showed a similar broad linear range of 2.55 μM to 0.5 mM with a sensitivity of 285.38 μA mM−1 cm−2. The sensor also displayed selectivity toward glucose against AA and UA interferents and good stability at room temperature as the sensitivity was found to decrease by 12.5% after 4 weeks. Wang et al.257 prepared a Pt–NiO array/rGO nanocomposite-based biosensor with a sensitivity of 832.95 μA mM−1 cm−2, a linear range of 0.008–14.5 mM, and an LOD of 2.67 μM. The enhanced performance was ascribed to the strong catalytic activity of the metal–metal oxide (Pt–NiO) combined with rGO, as well as the high porosity of the nanocomposite material. Moreover, graphene functionalized with metal oxide nanoparticles such as nitrogen-doped rGO/Mn3O4 NPs253 or GO hydrogels/Co3O4 nanoflowers281 has been applied to the fabrication of biosensors with improved sensitivity and selectivity for the electrochemical detection of glucose. Dong et al.232 designed cobalt oxide nanowires (Co3O4 NWs)/3D-graphene foam with high porosity for nonenzymatic electrochemical glucose detection. The 3D graphene/Co3O4 nanocomposite sensor exhibited a sensitivity of 3.39 mA mM−1 cm−2, an LOD of <25 nM (S/N = 8.5) and anti-interference ability against AA, UA and proteins, which was attributed to the unique 3D porous nanostructures. Rao et al.270 reported an enzyme-free electrochemical glucose sensor based on a NiCo2O4/nitrogen-doped rGO/ionic liquid ternary composite. The resulting sensor showed high electrocatalytic activity toward glucose with a sensitivity of 3.76 mA mM−1 cm−2, a wide linear response from 0.001 mM to 4.555 mM and an LOD of 0.18 μM under a potential of 0.5 V. The enhanced sensitivity was attributed to the synergistic effect of the NiCo2O4, GO and ionic liquid. Moreover, the N-doping of rGO further expedited the electron transfer of the ionic liquid.
An approach to synthesize of rGO-encapsulated CuNPs using an electrostatic self-assembly method was reported by Zhang et al.,279 as shown in Fig. 10A. The obtained Cu core and rGO shell nanocomposite exhibited high stability compared to bare CuNPs because CuNPs in the composite were protected from oxidation by the rGO shell. The differential pulse voltammetry (DPV) response of glucose in 0.1-M NaOH was measured in the 1–2000 μM concentration range and showed a linear relationship between the peak current and the glucose concentration. Moreover, the resulting CuNPs/rGO nanocomposite exhibited high electrocatalytic activity with a wide linear range from 1 μM to 2 mM, a sensitivity of 150 μA mM−1 cm−2, and an LOD of 0.34 μM in addition to good reproducibility and selectivity for the oxidation of glucose (Fig. 10B). The selectivity of the CuNPs/rGO core–shell nanocomposite-based sensor for glucose detection was examined by measuring the normalized DPV peak current with addition of 1.0-mM glucose alone as the control and then in the presence of 2.0-mM UA, 2.0-mM DA and 2.0-mM AA as interfering analytes and the corresponding mixtures with glucose (Fig. 10C bottom). The resulting DPV peak current was 5.4, 8.9 and 6.3% for UA, DA, and AA compared with 1.0-mM glucose in 0.1-M NaOH, respectively, showing high selectivity for glucose detection in the presence of each interferent. Babu et al.277 fabricated nonenzymatic glucose sensors using 3D copper–cobalt/rGO (Cu–Co/rGO) nanostructures which were electrochemically deposited over a pencil graphite electrode (PGE) (Fig. 11A). The Cu–Co/rGO/PGE sensor displayed high glucose detection with enhanced sensitivity (240 μA mM−1 cm−2), a linear range of 1 μM to 4 mM, an LOD of 0.15 μM (Fig. 11B) as well as anti-interfering property against AA, UA, DA, citric acid (CA), NaCl, urea, acetaminophen (AP) and chloride poisoning resistance. The high analytical performance of the biosensor was associated with the 3D hierarchical dendrite-like architecture having controlled pore diameter, large surface area and high conductivity for rapid electron transfer.
3.2. Cholesterol biosensors
Cholesterol and its fatty acid esters are among the main constituents of mammalian cell membranes and are precursors of extra biological materials including steroid hormones and bile acid. Accurate determination of the cholesterol content in blood is very important for the diagnosis and prevention of various heart diseases. Excessive blood cholesterol is considered to be a severe threat for cardiovascular diseases such as atherosclerosis, hypertension, myocardial infarction, and cardiopathy.282 The accurate estimation of blood cholesterol is essential for the assessment of atherosclerosis and other lipid-related disorders and to determine the risk of thrombosis and myocardial infarction.283 A normal level of total cholesterol in the human blood is less than 5.17 mM, but this value can differ based on individuals and their age, body-weight, and gender. The higher limit of total cholesterol in human blood is in the range of 5.17–6.18 mM and cholesterol in values above 6.21 mM are considered high.283 Thus, biosensors for the precise detection of cholesterol in the human blood samples are critical for healthcare. Multiple analytical methods including electrochemical sensing have been developed for sensitive and selective monitoring of cholesterol.
Similar to electrochemical glucose biosensing, the sensing of cholesterol can be accomplished by two approaches. (i) The enzymatic reaction of cholesterol with cholesterol oxidase (ChOx), i.e., the concentration of cholesterol can be estimated by monitoring the concentration of hydrogen peroxide (H2O2) generated through the enzymatic reaction. The ChOx enzyme is most commonly used for the detection of cholesterol because it easily catalyzes the oxidation of cholesterol to cholest-4-3-one and H2O2.284 (ii) Enzyme-free direct biocatalytic oxidation of cholesterol.285 Various nanomaterials, such as metal and metal oxide nanoparticles, CNTs, GR, and polymer nanocomposites, have been successfully applied to develop cholesterol biosensors.286 Among the nanomaterials developed, graphene holds a great promise for the detection of cholesterol with highly enhanced sensitivity and selectivity due to its fast electron transport process, good mechanical properties and biocompatibility.286 Graphene-based cholesterol biosensors are summarized in Table 3.
Cholesterol biosensors developed from graphene nanocomposite-based modified electrodes and their linear detection range, sensitivity and limit of detectiona.
Graphene-based nanocomposites | Linear range | Sensitivity (μA mM−1 cm−2) | Limit of detection (LOD) | K m (mM) | Ref. |
---|---|---|---|---|---|
GR-PtNPs hybrid | Up to 12 mM | 2.07 | 0.2 μM | 5.0 | 287 |
Cholesterol esterase-functionalized GR | 50–300 μM | 443.25 | 15 μM | — | 288 |
ChOx/hemin–GR nanosheets | 0.17–1120 μM | — | 0.06 μM | — | 289 |
CeO2/GR composites | 12 μM to 7.2 mM | — | 4 μM | — | 290 |
TiO2–GR–Pt–Pd hybrid | 0.05 μM to 5.9 mM | — | 0.017 μM | 0.21 | 291 |
Pd–Pt NPs/GR nanocomposite | 2.2 μM to 0.52 mM | — | 0.75 μM | 0.11 | 292 |
MWCNTs/GO/thionine–AuNPs | 0.15–828 μM | — | 50 nM | — | 293 |
GR/PVP/PANI nanocomposite | 50 μM to 10 mM | — | 1 μM | — | 294 |
Self-assembled GR | 0.05–0.35 mM | 124.57 | 0.05 μM | 1.22 | 295 |
rGO/dendritic Pd nanostructure | 0.005–0.014 mM | — | 0.05 μM | — | 296 |
GR/IL | 0.25–215 μM | 4163 | 0.5 mM | 2.32 | 297 |
CS/GR nanocomposites | 0.005–1.0 mM | — | 0.715 μM | 17.39 | 298 |
MWCNTs/GO/AuNPs | 0.15–828 μM | — | 0.05 μM | — | 293 |
ZnO/AgNWs/GR–CS nanocomposites | 6.5 μM to 10 mM | 9.2 | 0.287 μM | 0.295 | 299 |
MB/calix[6]arene-functionalized GR | 0.50–50.00 μM | — | 0.20 μM | — | 300 |
Ag nanowires/CS/GO nanocomposite | Up to 400 mg dL−1 | 13.628 | 0.427 mg dL−1 | 2.813 | 301 |
CdTe QD/MWCNTs/rGO nanoribbons | 1 μM to 1 mM | — | 0.33 μM | — | 302 |
SiO2 NPs/rGO hybrid composite | 2.6–15.5 mM | 11.1 | 1.3 mM | 0.49 | 303 |
NiO flowers/CVD-grown GR | 2–40 μM | — | 0.13 μM | — | 304 |
PSS/polymeric IL/GR nanocomposite | 0.01–10.4 mM | — | 3.5 μM | — | 305 |
Polypyrrole/rGO/ChOx composite | 0.01–6 mM | 1095.3 | 3.78 μM | — | 306 |
GO-SH/AuNPs composite | 0.05–11.45 mM | 273 | 0.2 nM | 0.18 | 26 |
TiO2 nanowires/3D GR nanostacks | 0.05–8.0 mM | 3.82 | 6 μM | — | 307 |
rGO nanosheet/PEI hybrid | 2.5–25 μM | — | 0.5 μM | — | 181 |
CeO2/N-doped GR composite | 4.0 μM to 5 mM | — | 1.33 μM | — | 308 |
Ag/AuNPs–GO | 0.01–5000 μg mL−1 | 0.084 | 0.001 μg mL−1 | — | 309 |
Abbreviations used: CS: chitosan, ILs: ionic liquids, SPE: screen-printed electrode, MB: methylene blue, GO-SH: thiol-functionalized graphene oxide.
3.2.1. Enzymatic detection of cholesterol
Graphene-based nanocomposites have been extensively investigated for the fabrication of enzyme-based cholesterol sensors. For example, Dey et al.284 fabricated a redox enzyme-functionalized GO based biosensor by covalently conjugated the ferrocene (Fc) redox units to the GO backbone through diamine in order to facilitate the enhanced electron transfer rate. Fig. 12 shows the schematic of Fc-GO based biosensor the detection of cholesterol and mechanism of the enzymatic reaction, CV response of the biosensors in the absence and presence of cholesterol ester, UA and glucose and amperometric response of the cholesterol biosensor with subsequent addition of cholesterol at a fixed potential of 0.3 V. The biosensor showed a linear response ranging from 0.5 to 46.5 μM with a sensitivity of 5.71 μA μM−1 cm−2 and an LOD of 0.1 μM with a response time of 4 s for the detection of cholesterol. The Fc-GO based biosensors also exhibited a linear range of 0.001 to 0.02 mM and 0.2 to 19.7 mM, sensitivities of 5.85 μA μM−1 cm−2 and 20.71 μA mM−1 cm−2 with LODs of 0.1 μM and 1 μM for detecting UA and glucose, respectively. The clinical application of the Fc-GO biosensors was demonstrated by detecting cholesterol ester, UA and glucose in human serum samples. Li et al.298 showed a cholesterol biosensor based on a CS biopolymer/GR nanocomposite. The availability of amine (NH3/NH2) and hydroxyl (OH) side groups in CS biopolymer not only facilitates the stable conjugation of ChOx enzyme but also increased the DET between the enzyme and the electrode surface. The ChOx/CS-GR based biosensor exhibited a linear range of 0.005 to 1.0 mM with an LOD of 0.715 μM for cholesterol detection and selectivity against interfering bionalytes such as DA, AA, UA, and glucose. Ruecha et al.294 used graphene/poly(vinylpyrrolidone)/poly(aniline) (GR/PVP/PANI) nanocomposites to fabricate cholesterol biosensors. The sensor showed a linear range from 50 μM to 10 mM with an LOD of 1 μM and clinical use for cholesterol detection in human serum samples.
Combining the noble metal nanoparticles with graphene has been shown to significantly enhance the electrocatalytic properties and subsequent detection of cholesterol.161,296,310 Pt and Pd nanoparticles exhibit superior electrocatalytic activity to other noble metal nanoparticles. The fabrication of biosensor using PtNPs/GR287 and PdNPs/rGO296 hybrid nanostructures has been reported for the electrochemical detection of cholesterol. The PdNPs/rGO hybrid nanostructure-based biosensor displayed an increased sensitivity of 5.12 μA μM−1 cm−2 and an LOD of 0.05 μM, due to the high electrocatalytic activity of dendritic Pd nanostructures supported on rGO surface. Cao et al.292 developed a cholesterol biosensor based on bimetallic PtPd nanoparticles supported on CS-GR-functionalized GCE. Owing to the synergetic catalytic activity of Pt and Pd nanoparticles, the fabricated PtPdNPs-CS-GR biosensor showed improvement in the detection range from 2.2 × 10−6 to 5.2 × 10−4 M, and the LOD was 0.75 μM because of accelerated DET between the redox enzyme and the electrode surface. Metal oxide nanostructures supported on GR have also been used to develop cholesterol sensors. Komathi et al.307 used titanium dioxide (TiO2) nanowires supported on 3D graphene nanostacks for the fabrication of dual-mode cholesterol biosensors. The biosensor exhibited a sensitivity of 3.82 μA mM−1 cm−2 and an LOD of 6 μM. The sensing performance is slightly lower than that of previous metal nanoparticles supported on GO due to the lower electrocatalytic activity and conductivity of TiO2 nanostructures.
3.2.2. Nonenzymatic detection of cholesterol
The stability of enzymes such as GOx and ChOx is easily affected by factors such as temperature, humidity, pH, etc. Nonenzymatic detection has numerous advantages over the enzyme-based approach including simple fabrication process, reproducibility, stability, low cost and freedom from oxygen limitation.285 Therefore, significant research efforts have been focused on developing biosensors for nonenzymatic cholesterol detection. Moreover, owing to the strong catalytic ability and facile attachment of metal NPs to the electrode surface, GR-based nanocomposites have been extensively investigated as electrode materials.75
A nonenzymatic cholesterol sensor based on β-cyclodextrin (β-CD)-modified chemically converted graphene was reported by Agnihotri et al.311 Methylene blue (MB) was used as a redox indicator in complex to form a cholesterol-sensing matrix. The resulting sensor showed an LOD as low as 1 μM. Lakshmi et al.312 developed a biosensor using polyaniline nanofiber/graphene microflowers for the detection of cholesterol, achieving an enhanced sensitivity of 0.101 μA mg−1 dL cm−2 and an LOD of 1.93 mg dL−1. The biosensor showed high selectivity toward cholesterol detection against interfering bioanalytes including AA, citric acid, urea, glucose, and cysteine. Alexander et al.313 reported a nonenzymatic cholesterol sensor fabricated from a modified GO-based molecularly imprinted polymer (MIP). The GO-MIP based sensor showed high sensitivity with an LOD of 0.1 nM and a fast response time of 2 min. Rengaraj et al.304 developed a nonenzymatic cholesterol biosensor using nickel oxide (NiO)/graphene composite. The developed sensor displayed a sensitivity of 40.6 mA μM−1 cm−2, an LOD of 0.13 mM, and a fast response time of 5 s. Moreover, the biosensor showed the ability to detect the cholesterol content in a milk sample, reproducibility and long-term stability.
3.3. Hydrogen peroxide (H2O2) biosensors
Hydrogen peroxide (H2O2) sensors have attracted much research interest because H2O2 is not only a byproduct of numerous enzymatic reactions but also plays an important role as a mediator in clinical, food, pharmaceutical and environmental monitoring applications due to its superior oxidizing and reducing properties.66 In living organisms, H2O2 is a byproduct of enzymatic reactions involving different oxidases and plays an essential role in regulating various biological signaling transduction processes, and enzymatic biosensing appears feasible. Unfortunately, the overpotentials (300–600 mV against a reference electrode) applied to the working electrode usually generate a significant amount of interference.314 Thus, intensive investigations have focused on the development of H2O2 sensors with reduced oxidation/reduction overpotentials.66
Graphene-based nanomaterials have attracted extensive interest for sensing H2O2 because of their high specific surface area, good mechanical strength and superior electric conductivity.66 Furthermore, the integration of metal NPs onto the surface of graphene could significantly improve the active surface area to enable adsorption and speed up electron transfer processes of analyte between the electrode and detection molecules. Table 4 lists the H2O2 biosensors developed from graphene-based nanocomposites. Initially, Zhou et al.131 demonstrated a modified electrode with chemically reduced GO, showing a much lower onset potential of H2O2 oxidation/reduction at 0.2/0.1 V (vs. Ag/AgCl) than with a graphite-modified electrode. The enhanced performance is ascribed to the high electrocatalytic activity and surface defects. Hou et al.315 performed the organic salt-mediated preparation of pristine graphene and used it for the nonenzymatic electrochemical detection of H2O2. The biosensor exhibited improved electrocatalytic activity for H2O2 detection with a wide linear range from 2.0 to 437.0 μM with LOD of 0.19 μM. Yu et al.316 prepared multilayer composite films of (phthalocyaninato)(porphyrinato)europium(iii) triple-decker compound (Pc)Eu(Pc)Eu[trans-T(COOCH3)2PP] (1) and GO for the detection of H2O2. The combination of the high electrical conductivity and a large surface area of GO with the semiconducting triple-decker porphyrin compound in the indium tin oxide electrode enabled high H2O2-sensing activity because of the optimized triple-decker molecular packing on the GO surface. The triple-decker/GO sensor showed a sensitivity of 7.4 μA mM−1 with a wide linear range of 0.05–1800 μM, an LOD of 0.017 μM, and a response time of 0.03 s μM−1.
Hydrogen peroxide (H2O2) biosensors fabricated using graphene nanocomposite-based modified electrodesa.
Graphene-based nanocomposites | Linear range | Sensitivity (μA mM−1 cm−2) | Limit of detection (LOD) | Ref. |
---|---|---|---|---|
rGO/carbon ceramic with CdS-hemoglobin | 2–240 μM | 1.056 | 0.24 μM | 317 |
Carboxyl (COOH)-functionalized GO | 0.006–0.8 μM | — | 1 nM | 318 |
Porous CeO2/rGO xerogel composite | 60.7 nM to 3.0 μM | 1.978 | 30.40 nM | 319 |
PtNPs/graphene nanocomposite | 0.002–0.71 mM | — | 0.5 μM | 320 |
3D graphene/CNTs | 10 μM to 1 mM | 137.9 | 1 μM | 321 |
PtNPs/MnO2 nanowire/rGO paper | 2 μM to 133 mM | 129.5 | 1.0 μM | 322 |
Self-assembled AuNPs/rGO paper | 0.005–8.6 mM | 236.8 | 2.0 μM | 323 |
Prussian blue (PB)/CS/graphene sheets | 0.01–0.4 mM | 816.4 | 0.213 μM | 324 |
AuNPs/porous graphene films | 0.5–4.9 mM | 75.9 | 0.1 μM | 42 |
Nf/PdNPs@rGO-APTES composite | 0.7 μM to 13.5 mM | 1164.3 | 0.21 μM | 148 |
GR/Cu2O nanocubes | 0.3–7.8 mM | — | 20.8 μM | 235 |
GR/Ag nanocrystals | 0.02–10 mM | 183.5 | 3 μM | 325 |
Prussian blue NPs/GR paper | 1–7 mM | 25.0 | 5 μM | 326 |
AuNPs/rGO nanohybrids | 0.25–22.5 mM | 5.3 | 6.2 μM | 327 |
ZrO2/rGO nanocomposite | 0.1–1340 μM | — | 20 nM | 328 |
rGO/tyrosine | 0.1–2.1 mM | 69.07 | 80 μM | 329 |
rGO/mesoporous silica/AuNPs composite | 0.5 μM to 50 mM | 39.2 | 60 nM | 330 |
rGO/MnO2 nanotube nanocomposite | 0.1–30 mM | 303.9 | 0.82 μM | 331 |
Polypyrrole/rGO/AuNPs composites | 32 μM to 2 mM | 40.0 | 2.7 μM | 332 |
PtNPs/graphene–CNTs hybrid paper | Up to 25 μM | 1.41 | 10 nM | 333 |
AgNPs/CNT/rGO hybrid nanocomposite | 0.01–10 mM | — | 1 μM | 334 |
PtNPs/porous GR | 1–1477 μM | 341.14 | 0.50 μM | 335 |
Freestanding graphene papers | 1–30 μM | 500000 | 100 nM | 336 |
Hollow TiO2-modified rGO microspheres | 0.1–360 μM | 417.6 | 10 nM | 337 |
CuO/graphene nanosphere composite | 0.01–0.1 mM | — | 6.88 μM | 338 |
3D graphene–Fe3O4 QD composite | 274150 | 8 nM | 339 | |
rGO/AuNPs nanohybrids | 0.25 to 22.5 mM | — | 6.2 μM | 327 |
Ni(OH)2/rGO/MWCNTs | 10–9050 μM | 2042.0 | 4.0 μM | 247 |
Cytochrome c (Cyt c)/GO/CNT/AuNPs | 0.001–0.14 mM | 0.533 | 0.027 nm | 340 |
Pt nanospheres/flexible graphene silk | 0–2.5 mM | 150.8 | 0.2 μM | 169 |
rGO/nPPY composite | 1–4 μM | — | 34 nM | 341 |
Carbon QDs/graphene sheets | 10 μM to 1 mM | — | 300 nm | 342 |
Poly-l-histidine/rGO composite | 0.2–500 μM | 266.4 | 0.05 μM | 343 |
Hemin–graphene/PEDOT composite | 1.0 μM to 0.1 mM | 23.05 | 0.08 μM | 344 |
Ag nanowire/graphene hybrids | 10.0 μM to 34.3 mM | — | 1 μM | 345 |
Hollow AuPd NPs/N-doped GR | 0.1–20 mM | 5095.5 | 0.02 μM | 346 |
AgNPs/PANI/graphene composite | 0.25 to 2.25 mM | 7.46 | 0.03 mM | 347 |
CeO2/rGO nanocomposite | 0.1–500 μM | 4.65 | 0.021 μM | 348 |
GR/cobalt oxide (Co3O4) NPs | 0.2–211.5 μM | 13.52 | 0.06 μM | 349 |
AgNPs/GO nanocomposites | 0.02–23.1 mM | — | 8.7 μM | 350 |
rGO-PtNPs composite | 0.05–750.6 μM | 0.686 | 16 nM | 351 |
GR nanodots/gold | 0.005–4 mM | — | 1 μM | 352 |
AgNPs/CNTs/rGO nanocomposite | 0.01–10 mM | — | 1 μM | 334 |
Ag@Pt core–shell NPs/rGO | 5 μM to 12.4 mM | — | 0.9 μM | 353 |
NiCo2N/N-GR core–shell | 200 nM to 3.4985 mM | 2848.73 | 200 nM | 224 |
PdNPs/bilayer graphene | 0.004–13.5 mM | 115.1 | 1.5 μM | 354 |
rGO/PdNPs/ZnFe2O4 composite | 25 μM to 10.2 mM | 621.64 | 2.12 μM | 355 |
Graphene/cellulose microfiber | 0.05–926 μM | 0.49 | 0.01 μM | 356 |
3D porous N-doped GR | 0.6 μM to 2.1 mM | 1.0 | 0.3 μM | 357 |
PDA/GR QDs/AuNPs | 0.1–40 μM | 48.6 | 5.8 nM | 358 |
HRP/porous GR | 2.77–835 μM | — | 26.7 pM | 359 |
Nanowall-like Pd/rGO | 100 μM to 12 mM | — | 0.24 μM | 360 |
PEDOT:PSS/rGO/AuNPs | 5–400 μM | 677.0 | 0.08 μM | 361 |
rGO/Nafion/AgNPs | 1–10 μM | 0.4508 | 0.535 μM | 362 |
rGO/CuFe2O4 composite | 1 μM to 11 mM | 265.57 | 0.35 μM | 363 |
GR/organic salts | 2–37 mM | 1161.6 | 0.19 μM | 315 |
Cu2O/rGO paper | 0.001–1.47 mM | — | 0.37 μM | 364 |
Cobalt sulfide/rGO composite | 0.1 μM to 2.54 mM | 2.519 | 42 nM | 365 |
Au–Pt NPs/rGO composite | 0.005–4 mM | 1117.0 | 0.008 μM | 366 |
Abbreviations used: ChOx: cholesterol oxidase, PVP: polyvinylpyrrolidone, PANI: polyaniline, MWCNTs: multiwalled carbon nanotubes, PEI: polyethyleneimine, PEDOT: poly(3,4-ethylenedioxythiophene), HRP: horseradish peroxidase.
Noble metal nanoparticles such as Ag, Au, Pt, Pd, and Cu decorated on GO surface have attracted significant interest for developing electrochemical H2O2 sensors due to their unique catalytic properties.66,367,368 Guo et al.369 prepared Pt nanoparticle/graphene hybrid nanosheets through a microwave-assisted heating method and used it for the electrochemical sensing of H2O2. The modified electrode showed increased in electrochemical performance for the detection of H2O2 in the linear range of 1 to 500 μM with a detection limit of 80 nM. Moreover, the sensor exhibited high selectivity for the detection of H2O2 in the presence of UA and AA interferents. Ag and Au nanoparticles exhibit high catalytic ability toward H2O2. Zhan et al.370 demonstrated the hydrothermal synthesis of AgNPs and used them to decorate 3D graphene for a H2O2 sensor. Owing to the higher catalytic activity of AgNPs, higher conductivity and reactivity of the 3D graphene porous structure, the fabricated sensor showed a wide linear range between 0.03–16.21 mM and an LOD of 14.9 μM. One-dimensional Ag nanostructures such as Ag nanorods371 and nanowires345 were also decorated on graphene surface to design sensors with improved sensitivity for the detection of H2O2. In addition to metal nanoparticles, metal oxide nanostructures were also supported on graphene for fabricating H2O2 biosensors. Karthikeyan et al.363 developed copper ferrite (CuFe2O4) supported rGO nanocomposite-based sensor which showed a high sensitivity of 265.57 μA mM−1 cm−2, a linear range of 1 μM to 11 mM, and an LOD of 0.35 μM. Yusoff et al.362 developed a biosensor using rGO-Nafion@silver6 (rGO-Nf@Ag6) hybrid-modified GCEs for the detection of H2O2. The sensor exhibited high sensitivity 0.4508 μA mM−1, with an LOD of 0.535 μM due to the coupling of rGO-Nf with AgNPs, which enhanced the performance due to more active surface area that enabling the interaction of analyte and the fast electron transfer. Chen et al.372 developed a biosensor based on a PtNPs-carbon quantum dot (CQD)/ionic liquid-functionalized GO nanocomposite for detecting H2O2. The unique PtNPs-CQDs/IL-GO structure improved the electrocatalytic reduction of H2O2 and offered abundant active sites for involved electrochemical redox reactions. The fabricated sensor showed a linear range of 1 to 900 μM and an LOD of 0.1 μM for detecting H2O2. Sun et al.373 used PtNi nanowires on rGO for developing H2O2 sensor. The sensor showed with a wide linear range between 1 nM to 5.3 mM and an LOD of 0.3 nM for the sensing of H2O2 due to the plentiful active sites available through PtNi nanowires. Bai et al.366 developed nonenzymatic H2O2 sensors using Au and Pt alloy microspheres decorated on rGO. The resulting biosensor exhibited a sensitivity of 1117.0 μA mM−1 cm−2, a linear range of 0.005–4.0 mM and an LOD of 0.008 μM for the determination of H2O2. Deepalakshmi et al.224 used NiCo2N/N-GR/GCE sensor for nonenzymatic detection of H2O2. NiCo2N/N-GR core–shell nanostructure-based sensor detected 0.463 mM H2O2 concentration in human blood serum with 91.7% recovery, showed high selectivity toward H2O2 against interferents including DA, UA, AA, glucose, urea, and NaCl, and retained 91.05% and 98.52% of initial current response after 45 days at <5 °C and 3000 s, respectively.
The assembly of flexible electrodes using few-layer graphene nanosheets into different freestanding structures with high electrical conductivity, mechanical strength, and structural uniformity has shown great promise for the design of flexible biosensors.40 The biosensor performance can be optimized by controlling the particle size and morphology of inorganic NPs, and their degree of loading and uniform distribution on the freestanding graphene films. For instance, the homogeneous dispersion or self-assembly of the different nanoparticles over graphene nanosheets offers a large specific surface area and improved electron transport through conducting networks.374 Xi et al.42 prepared AuNPs containing porous graphene nanosheets by the electrostatic layer-by-layer (LbL) assembly of AuNPs with BSA to fabricate the electrode material for the detection of H2O2. The AuNPs/porous GR-based sensor exhibited enhanced electrochemical detection of H2O2 with a sensitivity of 75.9 μA cm−2 mM−1, a linear range from 0.5 μM to 4.9 mM, and an LOD of 0.1 μM compared with AuNPs/nonporous graphene composite. Xiao et al.323 developed flexible electrodes by assembling AuNPs on the freestanding GO paper. Specifically, the 2D array of AuNPs at oil–water interfaces were transferred on a freestanding GO paper, enabling a densely assembled monolayer of AuNPs on the surface of GO paper (Fig. 13). The fabricated sensor showed improved electrochemical properties, with a sensitivity of 236.8 μA mM−1 cm−2, a linear range of 0.005–8.6 mM and an LOD value of 2.0 μM (S/N = 3) for the detection of H2O2. The AuNPs/rGO paper-based sensor showed a linear range of 0.01 to 46 mM, sensitivity of 52.36 μA mM−1 cm−2, and the LOD of 5.0 μM for glucose detection. The AuNPs/GO paper hybrid electrode also showed long-term stability by retaining 96.8% of its initial peak current value for glucose oxidation after 200 cycles and over 90% initial catalytic current value up to 60 days after the electrode fabrication. Liang et al.169 prepared a freestanding graphene oxide-silk fiber nanocomposite film by then supported spiky structured PtNPs on the film substrate for fabrication of the H2O2 sensor. The resultant sensor based on spiky PtNP-decorated nanocomposite films showed a linear range of 0–2.5 mM, an LOD of 0.2 μM and the improved sensitivity of 0.56 mA mM−1 cm−2 for detecting H2O2 and the LOD of 1 μM with a sensitivity of 150.8 μA mM−1 cm−2 for the glucose detection.
Hybrid nanocomposites of 3D graphene with NPs have attracted tremendous attention because of their unique physical and chemical properties, such as high electron mobility, exceptional impermeability and a large specific surface area for the development of H2O2 sensors.132,375,376 Cheng et al.364 reported Cu2O microcrystals decorating highly porous 3D graphene aerogel (GA) for the electrochemical detection of H2O2. Fig. 14 shows the synthesis and photographs of 3D-Cu2O-GA and paper-like 2D Cu2O-rGO-P nanostructures, their SEM images and amperometric curves of 3D Cu2O-GA/GC and paper-like 2D Cu2O-rGO-P/GC composite electrodes after adding H2O2 in N2-saturated PBS solution at −0.4 V. The developed 3D Cu2O-GA-based biosensor exhibited high electrocatalytic activity for the reduction of H2O2 and improved sensing performance with a linear range from 1.0 μM to 1.47 mM and an LOD of 0.37 μM. The paper-like 2D Cu2O-rGO-P nanostructure showed further improved H2O2 sensing with a wide linear range of 5.0 μM to 10.56 mM and the LOD of 3.78 μM. Both sensors based on 3D Cu2O-GA and 2D Cu2O-rGO-P nanocomposites showed high selectivity toward the detection of H2O2 as no interference was observed from the trace amounts of DA, AA, UA and NaCl interferents. Lin et al.377 developed an electrochemical H2O2 sensor using 3D rGO structure decorated with molybdenum disulfide (MoS2) QDs. The developed rGO-MoS2 QD composite-based sensor exhibited a broad linear range of 0.01 to 5.57 mM, an LOD of 1.90 μM, and stability up to 18 days.
3.3.1. Detection of H2O2 in living cells
The development of biosensors to detect H2O2 from biological cells such as cancer cells is gaining a lot of interest. Zhang et al.378 reported a H2O2 sensor based on nitrogen- and sulfur-codoped GQDs/graphene nanosheets. The sensor displayed a wide linear range from 0.4 μM to 33 mM with an LOD of 26 nM, in addition to high selectivity, reproducibility and long-term stability for H2O2 detection in human serum samples and in the secretions released by Raw 264.7 cells. The NS-GQDs/GR hybrid nanocomposite exhibited high performance for the detection of H2O2 due to the high electrical conductivity, specific surface area and the availability of plentiful doping sites and edges. Sun et al.333 demonstrated the real-time electrochemical detection of H2O2 in live cells using a PtNP-decorated GR/CNT hybrid paper electrode. The flexible PtNP/GR–CNT hybrid paper-based sensor showed a linear range as low as 25 mM and an LOD of 10 nM and the sensitivity of 1.41 μA μM−1 cm−2. Zhang et al.379 developed a freestanding nanohybrid paper electrode using 3D ionic liquid-functionalized graphene supported by gold nanoflowers for the in situ electrochemical detection and real-time monitoring of H2O2 released from live breast cancer cells. The composite-based nonenzymatic electrochemical sensor showed sensitivity toward H2O2 with a linear range of 0.5 μM to 2.3 mM and an LOD of 100 nM due to the unique 3D structure and high electrocatalytic activity originating from the Au nanoflowers. Moreover, the developed sensor was able to discriminate normal breast cells (HBL-100) from the cancer breast cells (MDA-MB-231 and MCF-7 cells) and monitored H2O2 released from the breast cancer cells. Liu et al.335 reported PtNP-decorated porous graphene for detecting extracellular H2O2 released from the living cells. The biosensor showed good electrocatalytic reduction of H2O2 with a sensitivity of 341.14 μA mM−1 cm−2, a linear range of 1.0–1477 μM and an LOD as low as 0.5 μM. The improved sensor performance can be attributed to the uniform dispersion of PtNPs on the larger surface area and abundant active sites provided by the porous graphene nanostructure.
Maji et al.330 developed a sensor based on sandwich-like periodic silica-coated rGO-AuNPs for the detection of H2O2 released from living tumor cells (Fig. 15A). The sensor showed a sensitivity of 39.2 μA mM−1 cm−2, a wide linear range from 0.5 μM to 50 mM and an LOD of 60 nM. The sensor also detected glucose and H2O2 in human urine and nanomolar level sensitivity for H2O2 released from living HeLa and HepG2 tumor cells. Similarly, the detection of H2O2 in a biological system was accomplished Ju et al.380 using an electrochemical sensor based on AuNPs supported on nitrogen-doped GQDs (AuNPs/N-GQDs). The fabricated sensor exhibited high sensitivity and selectivity for the detection of H2O2 released from human cervical cancer cells with a sensitivity of 186.22 μA mM−1 cm2, a linear range of 0.25–13 327 μM and an LOD of 0.12 μM. The performance of the biosensor is attributed to the catalytic activity of the exposed (111) facets of the AuNPs and the dimension of the GQDs, which facilitate electron transfer between the AuNPs/N-GQDs and the GCE surface. Zhang et al.381 demonstrated an H2O2 sensor based on PtNPs/rGO nanocomposites to detect H2O2 from living cells (Fig. 15B). The sensor showed high sensitivity with a linear range from 0.5 μM to 3.475 mM and an LOD of ∼0.2 μM. Wang et al.382 prepared a modified electrode using rGO blended with dumbbell-like AuFe3O4 and Pt NPs (rGO/AuFe3O4NP/PtNP) for the detection of H2O2 released from living cancer cells (Fig. 15C). The fabricated rGO/AuFe3O4/PtNPs modified electrode-based sensor shows high catalytic activity and low overpotential for H2O2 detection. Moreover, the biosensor displayed improved selectivity and sensitivity with a linear range from 0.5 μM to 11.5 mM and an LOD of ∼0.1 μM as well as no interference from competing UA, AA and glucose bioanalytes. The sensor was used to measure the release of H2O2 from living cells, including both tumor cells and healthy normal cells using external stimulation where more H2O2 was released from tumor cells compared with normal cells. The quantity of H2O2 released from human cervical cancer cell HeLa was found to be to almost twice than that of normal hepatic cells LO2. The results showed nanocomposite-based biosensor as a promising platform for nonenzymatic H2O2 detection in clinical diagnostics to determine oxidative stress in different types of normal and diseases cells. Sun et al.383 reported a graphene-decorated intermetallic PtPb nanoplate (PtPb-NPs/GR) nanocomposite-based electrochemical sensor for the detection of H2O2. This sensor showed high electrocatalytic activity for the reduction of H2O2 with a linear range from 2 nM to 2.5 mM and an LOD of 2 nM. Moreover, the sensor also detected H2O2 released from Raw 264.7 cells. The high performance of this biosensor was attributed to the synergy between the PtPb nanoplates and graphene as well as abundance of electrocatalytic active sites available on the PtPb nanoplates. The same research group also fabricated H2O2 biosensor by assembling atomic-thick PtNi nanowires on rGO employing an ultra-sonic self-assembly technique.373 The resulting PtNiNWs/rGO-based biosensor exhibited electrocatalytic reduction of H2O2 in a wide linear range from 1.0 nM to 5.3 mM with an LOD of 0.3 nM at a potential of −0.6 V (vs. Ag/AgCl) and also detected real-time H2O2 release from a murine macrophage cell line (Raw 264.7 cell).
3.4. Nucleic acid (DNA/RNA) biosensors
The detection of nucleic acids has attracted attention due to the variability and specificity of the sequence. For example, NA biosensors can be used to detect single-stranded DNA (ssDNA) that can hybridize with the complementary strand. The high sensitivity and selectivity of these biosensors is important in gene engineering and in the diagnosis of genetic diseases since any damage to DNA molecules strongly influences genetic and chronic diseases.384 Several signal transduction methods have been employed for the detection of DNA, including fluorescence, electrochemistry, electrochemiluminescence (ECL), chemiluminescence (CL), colorimetry, and surface plasmon resonance (SPR).11 The electrochemical detection method is considered an efficient approach for NA detection because of its low cost, simple operation, high sensitivity, fast response, miniaturization, and easy use in molecular diagnosis. The electrochemical NA detection mechanisms involve binding to a probe immobilized on the sensing surface and thereafter monitoring the change in a generated signal. The sensitivity and specificity of NA detection depend strongly on the immobilization of specific probes and also on shunning nonspecific binding to the sensing surface.385
Graphene and its derivatives have attracted much interest for achieving fast, label-free, highly sensitive and selective DNA/RNA detection and sequencing.386 Owing to their unique molecular structure and electronic properties, DNA and RNA can easily form π–π bonds between their conjugated systems and the nucleobases.387 Theoretical studies have also provided evidence that the molecular interaction between DNA/RNA and graphene is highly dominated by weak non-covalent π–π interactions.388,389 Hence, the electronic structure of the graphene–nucleobase system can be easily tuned by altering the substrate surface and the adsorbate.390 Additionally, the inherent electrical conductivity of graphene and graphene-based derivatives support effective signal amplification. Table 5 summarizes the DNA/RNA biosensors developed from graphene-based nanocomposites and their sensing capabilities using different electrochemical methods.
Graphene nanocomposite-based biosensors for detecting nucleic acids and NADHa.
Graphene-based nanocomposites | Target | Detection technique | Linear range | Limit of detection (LOD) | Ref. |
---|---|---|---|---|---|
Nucleic acids | |||||
3D GR/AuNP nanocomposite | DNA | CV, EIS | 50 fM to 5.0 pM | 3.4 fM | 391 |
Poly(xanthurenic acid)/rGO composite | DNA | EIS | 0.1 fM to 0.1 nM | 4.2 fM | 392 |
SPAN/GO composite | DNA | EIS | 0.1 fM to 0.1 nM | 0.32 fM | 393 |
rGO modified GCE | Amelogenin gene | EIS, CV | 1 × 10−20 to 1 × 10−14 M | 3.2 × 10−21 M | 394 |
AuNPs/toluidine blue–GO composite | DNA | DPV | 10 pM to 1 nM | 2.95 pM | 395 |
GR/Au nanorods/polythionine | HPV | — | 0.1 pM to 0.1 nM | 40.3 fM | 396 |
Flower-like VS2/GR/AuNPs | AIV H5N1 gene | 0.5 pM to 0.5 nM | 52 fM | 397 | |
AuNPs/rGO/GCE | ssDNA | EIS, CV | 3 × 10−20 to 10−12 M | 1 × 10−20 M | 398 |
Au nanoclusters/GR | HIV gene | DPV | 0.1 fM to 100 nM | 30 aM | 399 |
EC-rGO/GR | DNA | CV, DPV | 10 fM to 1 μM | 0.158 fM | 400 |
GR/Au nanoclusters composite | DNA | LSV | 0.2 fM to 20 pM | 0.057 fM | 401 |
rGO/AuNPs | DNA | DPV | 0.1 pM to 10 nM | 35 fM | 402 |
AuNPs/rGO/PANI nanocomposite | DNA (Mycobacterium tuberculosis) | 1.0 fM to 1.0 nM | 1.0 fM | 403 | |
rGO | DNA | EIS | 1.0 fM to 1.0 nM | 0.029 fM | 404 |
N-doped GR/AuNPs | DNA | — | 10 fM to 0.1 μM | 3.12 fM | 405 |
rGO/ZrO2 nanocomposite | miRNA-21 | EIS | 10 fM to 0.1 nM | 4.3 fM | 406 |
GO nanosheet/AgNPs nanocomposite | DNA | DPV | 10 fM to 10 nM | 7.6 fM | 407 |
GR/Nafion composite | HIV gene | EIS | 0.1–100 pM | 0.23 fM | 408 |
EC-rGO | HIV gene | EIS | 1 pM to 1 nM | 0.3 pM | 409 |
p-rGO/AuNPs | ssDNA (Listeria monocytogenes) | DPV | 0.1 fM to 1 μM | 0.317 fM | 410 |
GR/flavin mononucleotides | DNA | DPV | 0.1 fM to 1.0 μM | 0.074 fM | 411 |
dsDNA/poly(l-cysteine)/Fe3O4 NPs/GO nanocomposite | DNA | CV, EIS | 0.01–30.0 μM | 3.48 nM | 412 |
Au-transferred CVD-grown GR | DNA | Hall | 1 pM to 100 nM | 1 pM | 413 |
rGO | DNA | 1 fM to 1 nM | 1 fM | 414 | |
Thionine functionalized rGO | DNA | DPV | 0.01 fM to 1 pM | 4.28 × 10−19 | 415 |
AQMS-rGO composite | DNA | DPV | 1 fM to 0.01 μM | 63 fM | 416 |
Au nanocages/GR nanoribbons | DNA | CV, EIS | 1 fM to 100 pM | 600 aM | 417 |
GR QDs | miRNA-155 | CV | 1 fM to 100 pM | 0.14 fM | 418 |
GO/Au nanorod nanocomposite | miRNA-155 | CV | 2.0 fM to 8.0 pM | 0.6 fM | 419 |
MgO nanoflowers/GO-AuNPs nanocomposite | miRNA | CV | 0.1–100 fM | 50 aM | 420 |
CS/N-doped rGO | miRNA | EIS | 5–20 μg mL−1 | 1.72 μg mL−1 | 421 |
N-doped GR/AuNPs/hemin/G-quadruplexes | miRNA | CV, DPV | 10 fM to 1 nM | 0.17 fM | 422 |
NADH | |||||
N-doped GR/AuNPs nanocomposite | NADH | CV | 1–100 μM | 300 nM | 423 |
rGO/AuNPs | NADH | CV | 0–500 μM | 0.6 μM | 160 |
GR-DNA tetrahedra/AuNPs | NADH | CV | 1.0 fM to 10 pM | 1.0 fM | 424 |
AuNPs/rGO nanocomposite | NADH | CV | 50 nM to 500 μM | 1.13 nM | 425 |
Poly(O-anisidine)/GR nanocomposite | NADH | CV | 0.166–1.772 μM | 1.3 μM | 426 |
N-doped GR | NADH | CV | 0.5–12 μM | 0.37 μM | 427 |
EC-rGO/AuNPs–PAH composite | NADH | CV | 0.01–0.2 mM | 3.5 μM | 428 |
FeN NPs/N-doped GR | NADH | 0.4–718 μM | 25 nM | 429 | |
GR/pyrroloquinoline quinone composite | NADH | DPV | 0.32–220 μM | 0.16 μM | 430 |
Au–AgNPs/poly(l-cysteine)/rGO nanocomposite | NADH | CV | 0.083 μM to 1.05 mM | 9.0 nM | 431 |
Abbreviations used: NADH: nicotinamide adenine dinucleotide, SWCNTs: single-walled carbon nanotubes, LSV: linear sweep voltammetry, MDR: multidrug resistance, HPV: human papillomavirus, PAH: poly(allylamine hydrochloride), AQMS: anthraquinone-2-sulfonic acid. AIV: avian influenza virus, CILE: carbon ionic liquid electrode, SPAN: sulfonated polyaniline.
Loan et al.413 demonstrated a Hall effect device consisting of gold films deposited on graphene layers for improved sensitivity in hybridization detection, with a wide linear range from 1 pM to 100 nM for the detection of DNA targets. AuNPs have been widely employed with graphene for the detection of DNA because covalent bonding between AuNPs and multiple thiolated probe ssDNAs supports both the loading efficiency and capacity. Wang et al.432 described an electrochemical DNA biosensor based on AuNP-decorated rGO. The biosensor showed good selectivity toward single-base mismatched target DNA with a linear detection range of 0.1 μM to 0.1 fM and an LOD of 35 aM. Huang et al.396 developed a DNA biosensor for electrochemical detection of human papillomavirus (HPV) using graphene/Au nanorods/polythionine (GR/AuNRs/PT). The fabricated DNA biosensor exhibited high performance for the detection of HPV DNA in a range from 1 × 10−13 to 1 × 10−10 mol L−1 with an LOD of 4.03 × 10−14 mol L−1. Wang et al.433 fabricated a peroxide mimic by loading iron(iii) meso-tetrakis(N-methylpyridinum-4-yl)porphyrin (FeTMPyP) and streptavidin onto graphene oxide. The designed biosensor was used to detect a biotinylated molecular beacon for the electrochemical detection of DNA (Fig. 16A). The sensor showed a high electrochemical response for detecting DNA with an LOD reaching to 22 aM and a broad linear relationship from 10 pM to 100 aM, ranging five orders of magnitude (Fig. 16B). Yang et al.411 fabricated an electrochemical DNA sensor using bifunctionalized graphene with riboflavin 5′-monophosphate sodium salt (FMNS). The GR/FMNS sensor performance was compared with that of the conventional electrochemical indicator ([Fe(CN)6]3−/4−). The designed DNA sensor exhibited high sensitivity, selectivity, and stability with an LOD of 8.3 × 10−17 M, which is slightly higher (7.4 × 10−17 M) than that of ([Fe(CN)6]3−/4−) indicator. Singh et al.434 developed a GO/CS nanocomposite-based DNA biosensor for the identification of typhoid. The biosensor was constructed by the covalent immobilization of a Salmonella typhi-specific 5′-amine-labeled ssDNA probe on GO-CS/ITO with GA as cross-linkers. The ssDNA/GO-CS-based biosensor can effectively differentiate between complementary, non-complementary and one-base mismatch sequences with a detection range of 10 fM to 50 nM and an LOD of 10 fM within hybridization times of 60 s for the complementary sequence. Moreover, the resulting ssDNA/GO-CS biosensor enables the detection of complementary targets in serum samples with a low LOD of 100 fM. The high performance of the sensor originated from the electrochemical activity of GO and to the capability of CS biopolymer to enhance the DNA immobilization and enable the electron transfer between DNA and the ITO electrode surface.
The integration of AuNPs with GO or rGO is another valuable approach for developing DNA biosensors. Peng et al.395 reported a label-free electrochemical DNA biosensor for the detection of multidrug resistance (MDR) gene using AuNPs/toluidine blue (TB)-GO-modified electrode. The AuNPs/TB-GO based sensor showed an LOD of 2.95 pM with good selectivity. Han et al.435 fabricated sensor from gold nanorods (AuNRs) supported on GO nanosheets. The constructed DNA sensor detected complementary DNA from 1.0 nM to 10 fM with an LOD of 3.5 fM. Moreover, the sensor showed high selectivity as it can effectively discriminate complementary DNA sequences from a large quantity of single-base mismatched DNA from a ratio of 1000 : 1. Fang et al.397 developed a label-free electrochemical aptasensor using the self-assembly of DNA aptamers on flower-structured VS2 and AuNPs supported on graphene for the detection of DNA. Specifically, the gene sequence of avian influenza virus H5N1 was selected as the target DNA, and the [Fe(CN)6]3−/4− solution was employed as the electrochemical indicator. This VS2/AuNPs/GR composite-based sensor displayed a wide linear detection range from 5.0 × 10−13 to 5.0 × 10−10 M with an LOD of 52 fM for the detection of the H5N1-specific genetic sequence. Jayakumar et al.436 synthesized a 3D nanoarchitecture based on the layer-by-layer (LbL) assembly of AuNPs, which was supported by poly(amido-amine) dendrimer using rGO as a core for the ultra-low level detection of DNA hybridization, as shown in Fig. 17. Specifically, the biosensor was designed using [Fe(CN)6]3−/4− for covalent immobilization of thiol-functionalized ssDNA. The DNA biosensor was fast, highly sensitive and selective for DNA hybridization with a linear range of 1 × 10−6 to 1 × 10−13 g m−1 and achieved an LOD of 9.07 × 10−14 g m−1.
Several signal enhancement strategies to amplify DNA detection have been demonstrated. For example, Wang et al.399 reported an electrochemical biosensor for human immunodeficiency virus (HIV) gene detection using graphene/Au nanoclusters (GR/AuNCs) with an exonuclease III (Exo III) amplification strategy (Fig. 18). The biosensor platform having extremely high specific area offered more fixed active sites for the cyctosine (C)-rich capture probes. The biosensor exhibited high sensitivity and selectivity toward HIV target DNA with an LOD of 30 aM. The GR/AuNCs biosensor showed high selectivity toward detecting HIV target DNA (10 nM concentration), compared with 10 times larger concentrations of three other interfering DNA sequences; single-base mismatched DNA (100 nM), four-base mismatched DNA (100 nM), and unmatched DNA (100 nM) as well as high reproducibility for detecting HIV target DNA with five different electrodes. Moreover, the resulting GR/AuNCs biosensor showed good performance in HIV-infected human blood DNA. Wang et al.401 developed an electrochemical DNA biosensor based on functionalized Au nanoclusters/graphene hybrids and Exo III-supported cascade target recycling (Fig. 19). In this designed biosensor, Exo III-supported cascade recycling that was induced by the target DNA, resulted in the final cleavage product, which acted as a linker between the capture probe and the functionalized Au nanoclusters/GR nanohybrid acting as interface. Using this signal enhancement strategy, the fabricated biosensor showed DNA detection range from 0.02 fM to 20 pM and an LOD of 0.057 fM. Functionalized Pt nanoclusters/graphene hydrid-based biosensor also detected DNA using the catalysis of 3′,5,5′-tetramethylbenzidine-hydrogen peroxide (TMB-H2O2) an electrochemical signal.
3.4.1. Graphene nanopore-mediated DNA detection
Graphene nanopores have emerged as a promising route to fabricate devices for simultaneously measuring the ionic current and changes in local voltage in the transistor.437–439 Graphene atomic layers serve as an efficient membrane that allows single-base resolution in an ionic current because of its single atomic-layer thickness.440 Sadeghi et al.441 demonstrated DNA sequencing using bilayer graphene with nanopores by observing the current–voltage characteristics of a bilayer graphene junction. Liu et al.403 reported an electrochemical DNA sensor based on the signal amplification of rGO and gold nanoparticles/polyaniline (AuNPs/PANI) hybrid composite for detecting specific DNA insertion sequence IS6110 of pathogenic bacteria Mycobacterium tuberculosis. The sensor showed specificity in the wide linear range from 1.0 × 10−15 and 1.0 × 10−9 M.
3.4.2. Graphene-based miRNA detection
Similar to DNA (nitrogenous bases of DNA are guanine (G), adenine (A), cytosine (C), thymine (T)), RNA is also a chain of nucleotides having four nitrogenous bases guanine (G), adenine (A), cytosine (C) and uracil (U); however, it is usually single stranded. MicroRNAs (miRNAs) are small, endogenous and single-stranded noncoding RNAs (approximately 18–25 nucleotides) that play vital roles in regulating gene expression through messenger RNA (mRNA) degradation or translational repression.442 MiRNAs are involved in many physiological processes of the human body, such as cell proliferation, differentiation and apoptosis, and their abnormal regulation will result in various diseases, including different types of cancer, kidney disease, central nervous system disease, cardiovascular disease, diabetes and viral infections.443 Therefore, the precise and rapid detection of multiple miRNAs is of great importance to control and prevent various types of diseases. The isolation of miRNA is commonly carried out through commercial kits; however, there are several limitations since the kits contain numerous interfering RNAs, and the concentration of miRNA is not sufficient for detection.443 Several strategies have been explored for the sensitive detection of miRNA through significant challenges to improve the sensitivity, detection limit and sensitivity still remain. Several signal amplification strategies have been studied to enhance the sensitivity.443 Different approaches for the signal amplification are included in Table 5.
GO and rGO exhibit strong affinity for single-stranded nucleic acids (ssNAs) via hydrogen bonding or π–π interactions.444 Hence, GO and rGO have been extensively used for sensing miRNAs. Hu et al.418 developed a miRNA electrochemical biosensor based on a GQDs and horseradish peroxidase (HRP). The GQDs/HRP can efficiently catalyze the H2O2-supported oxidation of 3,3,5,5-tetramethylbenzidine (TMB), resulting in an enhanced electrochemical signal and improved performance of the biosensor with a linear range from 1 fM to 100 pM and an LOD of 0.14 fM. Azimzadeh et al.419 reported an electrochemical nanobiosensor for detecting plasma miRNA-155 utilizing GO sheets decorated with thiol-functionalized gold nanorods (AuNRs), which were deposited on a GCE surface. The biosensor showed a linear range from 2.0 fM to 8.0 pM, with an LOD of 0.6 fM for detecting the target miRNA and was able to differentiate between complementary target miRNA, non-complementary, single- and three-base mismatch miRNA; therefore, this sensor was also used in clinical detection of the breast cancer cells. Cardoso et al.445 fabricated an electrochemical biosensor for monitoring miRNA-155 down to the attomolar concentration level in breast cancer cells. The sensor was fabricated in two steps: first the immobilization of anti-miRNA-155 onto the thiol-modified gold-screen-printed electrode and then followed by protecting the areas of nonspecific binding using mercaptosuccinic acid. The sensor detected miRNA-155 in a linear range from 10 aM to 1.0 nM with an LOD of 5.7 aM in human serum. The biosensor also showed selectivity for the breast cancer antigen (CA-15.3) and BSA without any interference from cell lines of melanoma. The graphene-based biosensors can be used for clinical diagnosis of various diseases.
3.5. Detection of enzymes
Nicotinamide adenine dinucleotide (NADH) is a coenzyme involved in metabolic processes, and the NAD+/NADH redox couple (standard redox potential for half-reaction = −0.32 V) is involved in numerous enzymatic reactions in biological systems. A high overpotential (e.g., 0.6 V vs. SCE) is needed for the direct oxidation of NADH with traditional electrodes.446 Moreover, the electrooxidation of NADH is mostly an irreversible reaction, which causes significant polluting of electrodes.74 Graphene-based electrode materials have shown a great promise for the electrochemical detection of NADH with reduced overpotential and such results are summarized in Table 5. Tabrizi and Zand447 reported synthesis of rGO using NADH as a mild reducing agent. The GO-modified electrode showed high electrocatalytic activity for the oxidation of NADH, the detection of NADH at a reduced potential of 1.35 V with an LOD of 0.6 μM. Govindhan et al.425 developed an electrochemical NADH sensor using a AuNPs/rGO nanocomposite without any redox mediators or enzymes. The fabricated sensor showed a sensitivity of 0.916 μA μM−1 cm−2, a linear range of 50 nM to 500 mM and an LOD of 1.13 nM, with no interference from AA, glucose, glutathione, or quinine bioanalytes. Mutyala et al.427 developed a NADH biosensor using nitrogen-doped graphene-modified electrodes. The NADH biosensor displayed an enhanced sensitivity of 0.16 μA μM−1 with a linear range of 0.5–12 μM and an LOD of 0.37 μM. Moreover, the sensor exhibited stability after a period of 15 days with low surface contamination. Balamurugan et al.429 reported an iron nitride (FeN) nanoparticle-encapsulated nitrogen-doped graphene for the electrochemical detection of NADH. Fig. 20 shows the fabrication and NADH measurement mechanism for the FeN NPs/NG core–shell hybrid electrode based biosensor, high selectivity of FeN NPs/NG/GCE toward NADH against interfering bioanalytes including glucose, UA, DA, and AA at an applied potential of +0.35 V, and also high stability of FeN NPs/NG/GCE sensor with 98.18% retention of initial current after 1000 cycles. The sensor exhibited sensitivity of 0.028 μA μM−1 cm−2, a wide linear range of 0.4 to 718 μM, and an LOD of 25 nM. In addition, the FeN NPs/NG/GCE biosensor showed negligible interference effects in the presence of common bioanalytes existing in human serum samples. Li et al.424 fabricated a graphene-DNA tetrahedron-gold nanoparticle (AuNP)-modified gold disk electrode for the detection of NADH which showed a very low of LOD of 1 fM with a significantly decreased potential of 0.28 V (vs. Ag/AgCl). The graphene biosensors can be used for the clinical diagnosis of NADH-related diseases.
3.6. Detection of dopamine (DA), ascorbic acid (AA) and uric acid (UA)
Dopamine is known to be a neurotransmitter present in the brain, and its level impacts the physiological functions in human body and also helps effect the treatment of disorders related to the central nervous system including Parkinson disease.448 The electrochemical biosensors have been widely employed to detect a variety of biochemicals such as neurotransmitters in the brain.449–451 DA, AA and UA exhibit electrooxidation peaks at nearly the same potentials; therefore, many studies have focused on separating their signal potential with enhanced sensitivity and selectivity.452,453 Ascorbic acid is an essential component of the human diet that helps prevent scurvy. It is present in the mammalian brain together with several neurotransmitter amines such as dopamine, epinephrine and norepinephrine. Moreover, UA and other oxypurines are the main products of human's purine metabolism. High levels of UA can lead to several diseases, including hyperuricemia, gout and Lesch–Nyhan disease. Therefore, accurate detection of DA, AA and UA is highly desirable in clinical monitoring and diagnosis of such diseases.
Carbon-based nanomaterials such as CNTs and GBMs have been studied for the electrochemical detection of DA, AA, and UA due to their unique electronic structure, high surface area, and electrical conductivity.19,454 Graphene and GO have emerged as the most promising electrode materials for the detection of a wide range of analytes because of their enhanced electron transfer rate and structural orientation.455,456 The simultaneous detection of DA, AA, and UA using graphene-based electrodes has been accomplished and such data are summarized in Table 6. Gao et al.457 reported a GO-modified GCE for the selective detection of DA in the presence of interfering AA bioanalyte. The designed biosensor showed an LOD of 0.27 μM for detecting DA, while no interference was observed by the addition of AA. The electrostatic repulsion between the GO and AA biomolecules makes the oxidation of AA difficult at the electrode surface. In comparison, the π–π stacking as well as the electrostatic attraction between dopamine aromatic ring and delocalized π-electrons of GO promotes the oxidation. Li et al.458 used 3D nanocomposite based on MoS2 nanospheres, PANI loaded on rGO for simultaneous electrochemical detection of AA, DA and UA. Fig. 21 shows the differential pulse voltammetry (DPV) curves of MoS2-PANI/rGO/GCE electrode-based sensor and the plot of peak currents as a function of AA, DA and UA concentrations. The oxidation peak currents showed a linear increase with increasing AA, DA and UA concentrations. The MoS2-PANI/rGO nanocomposite-based sensors displayed sensitivity over wide concentration ranges and low LODs for AA, DA and UA. DPV curves measured with MoS2-PANI/rGO/GCE electrode for a ternary nanocomposite of AA, DA, and UA biomolecules with their different concentrations showed three well-defined anodic peaks at different potentials; 0.052 mV for AA, 0.196 mV for DA, and 0.304 mV for UA and simultaneously detected these three analytes with LODs of 2.49, 0.65 and 0.40 μM for AA, DA and UA, respectively. The electrochemical sensor also showed high selectivity toward AA, DA and UA in the presence of interfering analytes including ZnSO4, NaNO3, glucose, citric acid, and glycine. Devaramani et al.456 used a covalently linked p-aminobenzene sulfonate multilayer on the surface of a graphite pencil core electrode for selectively detecting dopamine. The sensor exhibited a linear range of 0.5–10 μmol L−1 and an LOD of 0.095 μmol L−1 (S/N = 3).
Graphene-based biosensors for detecting dopamine (DA), ascorbic acid (AA), and uric acid (UA)a.
Graphene-based nanocomposites | Linear range (μM) | Limit of detection (μM) | Sensitivity | Ref. | ||||
---|---|---|---|---|---|---|---|---|
AA | DA | UA | AA | DA | UA | |||
GR | 4–100 | 2.64 | — | 459 | ||||
GR/PtNPs | 0.15–34.4 | 0.03–8.13 | 0.05–11.85 | 0.15 | 0.03 | 0.05 | 0.969 | 460 |
MWCNTs/GO nanoribbons | 0.1–8.5 | 0.15–12.15 | 0.15–11.4 | 0.06 | 0.08 | 0.07 | — | 461 |
MoS2-PANI/rGO nanocomposite | 50–8000 | 5.0–500 | 1.0–500 | 22.20 | 0.70 | 0.36 | — | 458 |
N-doped GR | 5–1300 | 0.5–170 | 0.1–20 | 2.2 | 0.25 | 0.045 | — | 462 |
Screen-printed GR | 0–4500 | 0.5–2000 | 0.8–2500 | 0.95 | 0.12 | 0.20 | — | 463 |
AuNPs/β-cyclodextrin/GR | 300–2000 | 0.50–150 | 0.5–50 | 10 | 0.15 | 0.21 | — | 464 |
Pd NPs/GR/CS composite | 100–4000 | 20–200 | 0.5–200 | 20 | 0.1 | 0.17 | — | 465 |
N-doped carbon spheres/rGO | 50–1200 | 0.5–90 | 1–70 | 0.65 | 0.012 | 0.018 | — | 466 |
GR/CS nanocomposite | — | 0.1–140 | 1–125 | — | 0.05 | 0.1 | — | 467 |
Polyaniline/GO fibrous nanocomposite | 25–200 | 2–18 | 2–18 | 20 | 0.5 | 0.2 | 2.0 | 468 |
Tryptophan/GR | 0.2–3.4 | 0.5–10 | 10–1000 | 10.09 | 0.29 | 1.24 | — | 469 |
Polyimidazole/GO copolymer | 7–2275 | 12–278 | 3.6–249.6 | 18 | 0.63 | 0.59 | — | 470 |
CTAB-GO/MWCNTs | 5.0–300 | 5.0–500 | 3.0–60 | 1.0 | 1.5 | 1.0 | — | 471 |
PtNPs/GR–CNTs composite | 200–900 | 0.1–30 | 0.1–50 | 50 | 0.01 | 0.01 | 9.199 | 472 |
Pristine GR | 9–2314 | 5–710 | 6–1330 | 6.45 | 2.0 | 4.82 | 112.5 | 473 |
Ni–Co hexacyanoferrate/GR | 0.5–2000 | 0.2–500 | — | 0.15 | 0.06 | — | 474 | |
GR/CNTs/sulfonated CS | 1.25–442 | 1.25–357 | 1.25–533 | 0.06 | 0.06 | 0.06 | 1.68 | 475 |
AgNWs/rGO | 45–1550 | 40–450 | 35–300 | 0.81 | 0.26 | 0.30 | — | 476 |
rGO-CNTs/ITO | 10–200 | 0.2–8 | 0.2–16 | 5.31 | 0.04 | 0.17 | — | 477 |
Au@PdNPs/rGO composite | 1–800 | 0.1–100 | 0.1–350 | 0.28 | 0.024 | 0.02 | — | 478 |
N-doped GR flakes | 80–2000 | 0.5–150 | 3–60 | 0.58 | 0.015 | 0.015 | — | 479 |
Hemin–GO sheets | 1–100 | 0.5–40 | 0.5–50 | 0.3 | 0.17 | 0.17 | — | 480 |
Pd@Ag nanoflowers/rGO | 1–4100 | 0.05–112 | 3–186 | 0.185 | 0.017 | 0.654 | — | 481 |
GR fibers/NiCo2O4 | 200–750 | 1–13 | 10–26 | 50 | 0.1 | 0.2 | — | 482 |
PtNPs/GR paper | 0.087–100 | — | — | 0.005 | — | 2.00 | — | 483 |
GR/ZnO composite | 50–2350 | 1–70 | 3–330 | 3.71 | 0.33 | 1.08 | — | 484 |
PAA/polypyrrole/GO | 300–440 | 32–60 | — | 1.962 | 1.025 | — | — | 485 |
PAM/polypyrrole/GO | 150–220 | 6–13 | — | 0.659 | 0.408 | — | — | 485 |
β-NiS/rGO/AuNPs | 0.90–100 | 0.1–100 | 0.331 | — | 0.0045 | — | 486 | |
AuNPs/rGO | — | 0.05–11 | 0.1–11 | — | 0.02 | 0.03 | — | 487 |
CVD-grown GR | 5–1500 | 0.25–75 | 0.4–120 | 1.58 | 0.06 | 0.09 | — | 488 |
3D GR hydrogel/AuNPs | 1.0–700 | 0.2–30 | 1–60 | 0.028 | 0.0026 | 0.005 | — | 489 |
Ferrocene/3D GR hydrogel | 20–450 | 10–180 | 8–400 | 0.183 | 0.042 | 0.067 | — | 490 |
GR/porous CS composite | — | 1–700 | 1–800 | — | 0.14 | 0.17 | — | 491 |
Abbreviations used: HP: hydrophilic polymer, CNT: carbon nanotubes, CTAB: cetyl trimethylammonium bromide, PPy: polypyrrole, CVD: chemical vapor deposition, GRHG: graphene hydrogel, PAA: polyacrylic acid, PAM: polyacrylamide.
To enhance the high electrocatalytic activity and sensitivity, graphene and GO can be doped with nitrogen,466,492 modified with polymers,467,468,470 and decorated with different inorganic metal and metal oxide nanoparticles19 for the amplified detection of DA, AA, and UA. Yue et al.493 reported a vertically aligned ZnO nanowire array (NWA) assembled on 3D GF and applied to the detection of UA, DA and AA employing DPV technique, as shown in Fig. 22. The fabricated ZnO NWA/GF sensor showed high selectivity for both UA and DA with an LOD of 1 nM. DA and UA are considered biomarkers for the diagnosis of Parkinson disease. The sensors exhibited high performance in real samples for the detection of UA levels at 265 ± 20 μM in the serum of patients suffering from Parkinson disease compared to UA levels of 355 ± 30 μM in healthy individuals. Srivastava et al.494 prepared functionalized multilayer graphene for developing an amperometric urea biosensor that showed a linear range from 10 to 100 mg dL−1 and a high sensitivity of 5.43 μA mg−1 dL cm−2 with an LOD of 3.9 mg dL−1. Dutta et al.495 fabricated an enzyme-free urea sensor employing a nanocomposite of SnO2 QDs/rGO. Due to the synergistic effect between these components, the developed sensor displayed high electrochemical activity for the detection of urea in a linear range of 1.6 × 10−14 to 3.9 × 10−12 M and a very low LOD of 11.7 fM.
3.7. Detection of cancer biomarkers
The foremost cause of human death worldwide is cancer. The accurate detection and diagnosis of cancer during its early stage is significantly important for its successful treatment.496 Cancer diagnostic techniques such as blood analysis, clinical bioimaging and morphological changes in cancer cells have been widely employed for cancer diagnosis. However, these techniques still lack the required sensitivity, selectivity and reproducibility; therefore, these are not so accurate in the precise early stage detection of cancer cells.497 The use of cancer biomarkers seems more promising for early stage cancer detection, monitoring, diagnosis and subsequent treatment.498,499 A biomarker is defined as a biological feature that can be an indicator of both normal and abnormal biological processes, pathogenic conditions, or pharmacological responses to applied therapeutic interventions.500 There is an increasing demand for disease diagnostic tools which require highly sensitive and accurate methods for detecting cancer-related biomarkers.69,499 In particular, the clinical detection of cancer biomarkers is critically important for early-stage diagnosis of cancer-related diseases and proteomics research to understand of the biological processes involved in causing cancer.501 To discard false positives in the diagnosis of cancer that may result from the population inequality in the genetic expression of a single biomarker, concurrent detection of a series of protein biomarkers are required.498 In recent years, electrochemical techniques have become attractive for the immunoassay of protein biomarkers, owing to their low cost, simplicity, high sensitivity, and miniaturization. However, their sensing performance still needs to be improved for rapid and sensitive detection.
Nanomaterials offer potential platforms to diagnosis and treatment of cancer; therefore, research efforts have moved from the preclinical stage to practical point-of-care applications.502 Nanomaterials such as metal NPs, magnetic NPs, QDs, and CNTs have been studied in the design of biosensors to increase the sensitivity of electrochemical detection techniques.503–505 Graphene and GO are particularly attractive materials for use in biomarker detection owing to their easy surface modification chemistry and unique electrocatalytic, optical, chemical, and electrical properties.506,507 Furthermore, metal nanoparticles such as AuNPs have been used as immobilization matrices in developing electrochemical biosensors due to their strong adsorption abilities, easy surface modification, high stability and electrical conductivity.508Table 7 summarizes graphene-based nanocomposites using cancer biomarkers for various disease diagnosis. Zhu et al.509 developed an electrochemiluminescence immunosensor using CdSe QD-decorated poly(diallyldimethylammonium chloride)-graphene and gold nanoparticles for the detection of ractopamine. PDDA-graphene and AuNPs were used in order to improve electron conduction, efficient loading of antibodies, and to create a large surface area for antigen binding. The sensor showed a linear range of 0.01 to 1000 ng mL−1 and a low LOD of 2.6 pg mL−1 (S/N = 3) and displayed high stability as well as sensitivity for determining biomarkers. Kumar et al.510 developed PdNP-decorated rGO-based electrochemical sensor for the label-free detection of prostate-specific antigen (PSA), a prostate cancer biomarker. The fabricated biosensor exhibited a high sensitivity of 28.96 mA mL ng−1 cm−2 with an LOD of 10 pg mL−1. Ali et al.508 reported the green synthesis of metal (Pd, Pt, Ag and Au) nanoparticles on rGO sheets using a black pepper extract and applied the nanocomposite-based sensor to the detection of epidermal growth factor receptor in breast cancer diagnosis. The designed biosensor can be employed for detecting ErbB2 concentrations ranging from 1.0 fM to 0.5 mM. Chen et al.511 reported an immunosensor using graphene-based nanocomposites for simultaneously detecting multiple cancer biomarkers, such as carcinoembryonic antigen (CEA) and α-fetoprotein (AFP), as shown in Fig. 22A. In this study, the carboxyl-functionalized graphene nanosheet was first immobilized with toluidine blue and labeled with anti-CEA (Ab2,1) or immobilized with Prussian blue and labeled with anti-AFP (Ab2,2). Thereafter, the captured anti-CEA (Ab1,1) and anti-AFP (Ab1,2) were immobilized on a CS-AuNP-modified electrode via EDC/NHS. The developed biosensors showed a linear range of 0.5 to 60 ng mL−1 for both CEA and AFP bioanalytes and an LOD of 0.1 ng mL−1 and 0.05 ng mL−1 for CEA and AFP, respectively (Fig. 23B).
Graphene-based biosensors for detecting different cancer biomarkersa.
Graphene-based nanocomposites | Biomarkers | Detection technique | Linear range | Limit of detection | Ref. |
---|---|---|---|---|---|
CS/EC-rGO-AuNPs-Ag deposition | CEA | LSV | 0.5 pg mL−1 to 0.5 ng mL−1 | 0.12 pg mL−1 | 512 |
Carboxyl GR nanosheets/CS/AuNPs composites | CEA | DPV | 0.5–60 ng mL−1 | 0.1 ng mL−1 | 511 |
AFP | 0.05 ng mL−1 | ||||
CVD GR/AuNPs composite | CEA | EIS | 50–60 ng mL−1 | 5 ng mL−1 | 513 |
rGO/thionine/AuNPs composite | CEA | — | 0.01–300 ng mL−1 | 0.650 pg mL−1 | 514 |
AFP | 0.885 pg mL−1 | ||||
GR sheets/MWCNTs-CS/AuNPs | EBNA-1 | DPV | 0.05–6.4 ng mL−1 | 0.7 pg mL−1 | 515 |
APTES-ME-GR | hCG | CV | 0.62–5.62 ng mL−1 | 0.62 ng mL−1 | 516 |
GR/AuNPs nanocomposite | PSA | CV | 0–10 ng mL−1 | 0.59 ng mL−1 | 517 |
GO/Au nanorod composite | MiR-155 | CV, DPV | 2 fM to 8 pM | 0.6 fM | 419 |
Porous GR/TiO2 nanofibers | ErbB2 | DPV | 1.0 fM to 0.1 μM | 0.06 ng mL−1 | 518 |
ZrO2/rGO nanocomposite | CYFRA-21-1 | DPV | 2–22 ng mL−1 | 0.122 ng mL−1 | 519 |
AuNPs/GO nanocomposite | AFP | — | 0.001–80 ng mL−1 | 0.0002 ng mL−1 | 520 |
CEA | 0.0001 ng mL−1 | ||||
Au nanocages/rGO nanocomposite | Beclin-1, LC3B-II | DPV | 0.02–0.03 ng mL−1 | — | 521 |
AuNPs/GO nanocomposite | PSA | CV | 0.001 fg mL−1 to 0.02 mg mL−1 | 5.4 fg mL−1 | 522 |
AuNPs/PDA@GR nanocomposite | Ki67 protein | EIS | 4–800 pg mL−1 | 1.7 pg mL−1 | 523 |
TB/Cu2O@GO nanocomposite | AFT | — | 0.001 pg mL−1 to 100 ng mL−1 | 0.1 fg mL−1 | 524 |
Streptavidin-N-doped GR | CEA | DPV | 0.02–12 ng mL−1 | 0.01 ng mL−1 | 525 |
PtPd/N-doped GR-QDs/AuNPs | CEA | CV, EIS | 5 fg mL−1 to 50 ng mL−1 | 2.0 fg mL−1 | 526 |
EC-rGO | NEFA, bHBA | SPE | 0.1–10 mM | 0.111 mM | 527 |
GO/ssDNA/PLLA NPs | VEGF | DPV | 0.05–100 ng mL−1 | 50 pg mL−1 | 528 |
PSA | 1–100 ng mL−1 | 1 ng mL−1 | |||
PtCu@rGO/g-C3N4 | PSA | CV | 50 fg mL−1 to 40 ng mL−1 | 16.6 fg mL−1 | 529 |
Green corona-metal NPs/rGO | ErbB2 | EIS | 1.0 fM to 0.5 μM | 1 fM | 508 |
AuNPs/GO nanocomposite | ErbB2 | CV | 0.37–10 nM mL−1 | 0.16 nM | 530 |
CD24 | EIS | 0.23 nM | |||
S-doped GR/PANI nanocomposite | CEA | SWV | 0.1 pg mL−1 to 0.3 ng mL−1 | 30 fg mL−1 | 531 |
NMP22 | 25 fg mL−1 | ||||
AgNPs/rGO/SPE | CEA | CV | 0.05–0.50 mg mL−1 | 0.035 μg mL−1 | 532 |
Mesoporous Pd@P NPs/NH2-GR | PSA | CV | 10 fg mL−1 to 50 ng mL−1 | 3.3 fg mL−1 | 533 |
S-doped rGO | 8-OHdG | EIS | 20–0.002 μM | 1 nM | 534 |
Fe3O4 NPs@GO nanosheets | PSA | CV | 9.8–624 pg mL−1 | 15 fg mL−1 | 535 |
PSMA | EIS | 15.6–7.8 ng mL−1 | 4.8 fg mL−1 | ||
GR-QDs-IL-Nafion composite | CEA | — | 0.5 fg mL−1 to 0.5 ng mL−1 | 0.34 fg mL−1 | 536 |
3D GR/AgNPs composite | CYFRA21-1 | DPV | 0.1 fM to 0.1 μM | 0.1 fM | 537 |
GO/Au nanorods nanocomposite | PSA | ECL | 0.5 pg mL−1 to 5.0 ng mL−1 | 0.17 pg mL−1 | 538 |
AgPt nanoring/rGO nanocomposite | CEA | CV | 5 fg mL−1 to 50 ng mL−1 | 1.43 fg mL−1 | 539 |
CdS QDs@PS/GO-PANI nanocomposite | K562 cells | — | 10 to 1.0 × 107 cells per mL | 3 cells per mL | 540 |
PBSE/CVD-grown GR/Cu | CEA | EIS | 1.0–25.0 ng mL−1 | 0.23 ng mL−1 | 541 |
Poly(catechol)/GO nanosheets/AuNPs | Acute lymphoblastic leukemia | DPV | 100 μM to 10 pM | 1 pM | 542 |
Hemin–GR/PdNPs nanocomposite | PSA | DPV | 0.025–205 ng mL−1 | 8 pg mL−1 | 543 |
Carboxylic group-functionalized GO (GO–COOH-SPCE) | MUC1 | DPV | 0.1 to 2 U mL−1 | 0.04 U mL−1 | 544 |
Polypyrrole/EC-rGO composite | BRCA1 gene | CV, EIS | 10 fM to 0.1 μM | 3 fM | 545 |
Abbreviations used: CEA: carcinoembryonic antigen, AFP: α-fetoprotein, DPV: differential pulse voltammetry, NMP22: nuclear matrix protein 22, SWV: square wave voltammetry, NEFA: nonesterified fatty acids, bHBA: beta-hydroxybutyrate, ErbB2: epidermal growth factor receptor, MUC1: mucin1, AFT: a-fetoprotein, MPS: mesoporous silica, hCG: human chorionic gonadotropin, APTES: 3-aminopropyl-triethoxysilane, ME-GR: multilayer epitaxial graphene, SPE: screen-printed carbon electrode, 8-OHdG: 8-hydroxy-2′-deoxyguanosine, EBNA-1: Epstein–Barr virus nuclear antigen 1, TB: toluidine blue, SPE: screen-printed electrode, SPCE: screen-printed carbon electrode, VEGF: vascular endothelial growth factor, PSA: prostate-specific antigen, PSMA: prostate-specific membrane antigen, PDA: polydopamine, PS: polystyrene, PANI: polyaniline, BRCA: breast cancer gene, CYFRA21-1: cytokeratin fragment antigen 21–1, PLLA: poly(l-lactide), IL: ionic liquid, PBSE: 1-pyrenebutanoic acid succinimidyl ester.
Cancer biomarkers have been developed using graphene-based nanocomposites. Ren et al.531 used sulfur-doped GO/polyaniline (PANI) composite as a matrix and mesoporous NKF-5-3 as a label for developing tri-antibody dual-channel immunological biosensors for the detection of cancer biomarkers, such as carcino-embryonic antigen (CEA) and nuclear matrix protein 22 (NMP22) as shown in Fig. 24A. In this approach, two types of labels were prepared on the biosensor using two antibodies (anti-CEA anti-NMP22) and two antigens (CEA and NMP22). Toluidine blue (TB) and neutral red were employed as the signals to detect the CEA and NMP22 antigens. The immunosensor biosensor was incubated with two types of labels; AuNP-NKF-5-3|anti-NMP22|neutral red|BSA and AuNP-NKF-5-3|anti-CEA|TB|BSA which were NMP22 and CEA labels, respectively. The tri-antibody dual-channel immunosensor showed improved sensing performance having linear ranges of 0.1 pg mL−1 to 0.3 ng mL−1 for both NMP22 and CEA, and the low LODs of 25 fg mL−1 for NMP22 antigen and 30 fg mL−1 for CEA antigen. The immunosensor biosensor also exhibited high selectivity toward NMP22 and CEA in the presence of interfering bioanalytes including BSA, α-fetoprotein, human immunoglobulin G (HIgG), PSA, and breast cancer gene BRCA1 and can be used for the analysis of bladder carcinoma biomarkers. Ali Saeed et al.530 fabricated an electrochemical DNA biosensor for detecting the ErbB2 and CD24 biomarkers in order to evaluate breast cancer. Their strategy was based on a sandwich hybridization assay by immobilizing the capture DNA probe of the target DNA on GO-modified AuNPs (Fig. 24B). An HRP-labeled probe was used to detect the concentration of the DNA biomarker. The biosensor achieved the sensitivities of 378 nA nM−1 with an LOD of 0.16 nM for ErbB2 breast cancer biomarker and 219 nA nM−1 with LOD of 0.23 nM for CD24 control marker. Song et al.515 reported a sandwich-type electrochemical biosensor using an AuNPs/MWCNTs/GR/CS nanocomposite with a signal amplification strategy involving a hybridization chain reaction (HCR) for the detection of Epstein–Barr virus nuclear antigen 1 (EBNA-1). Similar to the sandwich immunoassay approach, the sandwich immune-reactions were initially formed by functionalization with the captured antibody, EBNA-1 and a secondary antibody in DNA-conjugated carboxyl MWCNTs. The double-stranded DNA (dsDNA) was formed from the HCR. This HCR-assisted amperometric signal amplification strategy significantly increased the detection range of target concentrations (0.05–6.4 ng mL−1) with an LOD as low as 0.7 pg mL−1. Jang et al.517 showed a 3D electrochemical immunosensor based on a GR/AuNP composite for the label-free detection of PSA over a linear range of 0–10 ng mL−1 with an LOD of 0.59 ng mL−1. Feng et al.529 reported a sandwich-type immunosensor for detecting PSA using AuNPs supported on thionine functionalized GO. In addition, bimetallic PtCu NPs were loaded on rGO/graphitic carbon nitride (g-C3N4) and used as labels for combining secondary antibodies (Ab2) and amplification of signals. The designed immunosensor displayed a linear range from 50 fg mL−1 to 40 ng mL−1 with an LOD of 16.6 fg mL−1 for the detection of PSA biomarker.
A chemical nose/tongue was developed by Wu et al.546 using a functionalized graphene array-based electrochemical biosensor for differentiating the cancerous, metastatic human breast cells, multidrug-resistant cancerous, and artificial circulating tumor cells (CTCs). This approach enables the biosensor to analyze different cell types at a very low level (100 cells). Fig. 25 shows the schematic of the cell detecting system, seven graphene derivatives including P1: BSA/chemically converted graphene (CCG), P2: CCG, P3: chitosan (Chit)/CCG, P4: polydopamine (DA)/CCG, P5: calf thymus DNA/CCG, P6: gelatin (Gel)/CCG, and P7: polyethylene glycol (PEG)/CCG, discrimination of 5 different human cancerous cell lines including lung (A549), cervical (HeLa), liver (HepG2), leukemia (K562), and breast (MCF-7) with P1–P7 graphene probes at a low cancer cell density of 100 cells, jackknifed classification using linear discriminant analysis (LDA) and canonical score plot for the graphene derivatives array-based biosensor. A single graphene array electrochemical sensor can detect 5 different human cancerous cell types for diagnostic purposes where two combined graphene derivative probes successfully obtained 100% classification accuracy. The LDA plots showed certain patterns and differentiated human cancerous cells from each other, having two canonical factors variance of 70.06 and 29.94% for P1 + P4, 68.66 and 31.34% for P1 + P5, 51.91 and 48.09% for P2 + P4, 82.95 and 17.05% for P2 + P5 for the A549, HeLa, HepG2, K562 and MCF-7 human cancerous cell lines. The LDA separated human cancerous cell lines into five discrete clusters. The functionalized graphene derivatives can be used for the application in the field of clinical cancer diagnostics.
3.7.1. Microfluidic electrochemical immunoassays
The microfluidic devices have attracted significant interest for point-of-care diagnostic systems.547 A microfluidics-based detection device is a promising approach for the detection of clinical biomarkers because of its simplicity, low cost, portability, low reagent consumption and capability of multiplex analysis using a single chip.548 Likely, a paper-based microfluidic device is also considered a simple approach for biosensing applications due to its low cost.549 Graphene-based materials have been used for fabricating microfluidic devices to detect cancer biomarkers at ultra-low concentrations. Wu et al.550 developed a paper-based microfluidic electrochemical immunodevice using graphene thin film for the multiplexed detection of four types of cancer biomarkers including AFP, CEA, cancer antigen 125 (CA125) and carbohydrate antigen 153 (CA153). They used horseradish peroxidase (HRP), antibody co-immobilized silica NPs and graphene to enable dual signal amplification, which enabled LODs of 0.001, 0.005, 0.001, and 0.005 ng mL−1 for AFP, CEA, CA125, and CA153 biomarkers, respectively. Ali et al.518 demonstrated a label-free microfluidic immunosensor fabricated using highly porous graphene foam (GF) integrated with carbon-doped TiO2 nanofibers for the detection of epidermal growth factor receptor 2 (ErbB2) proteins. Fig. 26 shows the functionalization of anti-ErbB2 molecules on the outer surfaces of GF and GF–nTiO2 electrodes, microscopic images of carbon-doped nTiO2, 3D GF and GF–nTiO2 nanocomposite, DPV curves in the presence of ErbB3 and ErbB4 antigens and histogram displaying the peak current in the presence of different interfering bionanalytes. The rodlike TiO2 nanofibers consisted of TiO2 grains. The GF has 500–600 μm size pores which are sufficient for the penetration of TiO2 nanofibers. The large surface area and porous structure of GF–nTiO2 composite allows easy adsorption of analytes. The sensor detected breast cancer biomarkers with a high sensitivity of 0.585 μA μM−1 cm−2, a very wide linear range of 1.0 fM to 0.1 μM concentrations of the target ErbB2 antigen and an LOD of 1 fM ErbB2. The peak current of the microfluidic sensor showed no significant change after adding 1 nM ErbB2 antigen to the mixed solution of interfering ErbB3, ErbB4, and ErbB3 + ErbB4 antigens, which indicated high selectivity toward ErbB2 in the breast cancer cells. The relative standard deviation (RSD) of ±1.0% was observed for the microfluidic sensor for 42 days storage at 4 °C, showing high stability due to strong molecular interactions between GF–nTiO2 composite and anti-ErbB2. Singh et al.551 demonstrated a microfluidic biochip fabricated using a microporous manganese oxide (Mn3O4)/rGO nanocomposite for human cardiac troponin I (cTnI) detection. The designed microfluidic chip showed high sensitivity, stability and reproducibility for the analysis of human cardiac troponin I molecules in a wide concentration range of 0.008 to 20 ng mL−1 and achieved an LOD of 8.0 pg mL−1 and negligible interference from other competing biomarkers including cardiac troponin C (cTnC), cardiac troponin T (cTnT), B-type natriuretic peptide (BNP), and myoglobin.
3.8. Detection of pathogens
Pathogens are key contaminants in water, including viruses, fungi, bacteria and protozoan parasites, and are responsible for various kinds of water-borne diseases. The presence of pathogens in water and food products is a major concern due to their rapid growth and harmful health effects to human.552–554 Furthermore, pathogenic microorganisms such as fungi, bacteria, viruses, viroids, phytoplasma and nematodes cause infectious diseases that lead to a decrease in agricultural productivity worldwide. The early detection of plant pathogens is an important first step to prevent plant disease in greenhouses, agricultural fields and at the national borders.555 A report from the World Health Organization (WHO) in 2007 indicated that the water- and food-borne infections account for approximately 4 billion episodes of diarrhea per year worldwide, causing approximately 1 to 2 million deaths.73 The real-time and sensitive detection of pathogens is of great importance to monitor and control such pathogen-related fatalities. Among the various pathogens, enterohemorrhagic Escherichia coli bacterial strains is the most life-threatening and serious foodborne outbreaks.556 Therefore, the sensitive detection and control of foodborne bacterial pathogens, such as Escherichia coli serotype O157:H7, remains a major scientific challenge in food safety in order to prevent severe diseases in humans.557 Nanostructured materials, including graphene and CNTs, have been exploited to fabricate electrochemical biosensors for the sensitive and selective detection of pathogens.73 Progress in the nanomaterial-based detection of pathogens through electrochemical methodologies has been reported previously.73,558 The electrochemical sensors for the detection of pathogenic bacteria using graphene-based nanocomposites are summarized in Table 8.
Graphene-based biosensors for the detection of pathogens, food toxins, and metal ionsa.
Graphene-based nanocomposites | Pathogen/food toxin | Detection method | Detection range | Limit of detection (LOD) | Ref. |
---|---|---|---|---|---|
Pathogenic bacteria | |||||
GO/CS nanocomposite | S. Typhi-specific DNA | DPV | 10 fM to 50 nM | 10 fM | 434 |
GO/iron oxide/CS composite | E. coli O157:H7 | EIS | 1 μM to 10 fM | 10 fM | 559 |
GO/nickel ferrite/CS composite | E. coli O157:H7 | DPV | 0.1 fM to 1 μM | 0.1 fM | 560 |
GO/thionine assembly | Cry1C | SWV | 0.01–100 ng mL−1 | 3.2 pg mL−1 | 561 |
rGO/AuNPs nanocomposite | S. aureus | EIS | 10 to 106 cell per mL | 10 CFU mL−1 | 562 |
GR/copper oxide–cysteine | E. coli O157:H7 | EIS | 10 to 108 CFU mL−1 | 3.8 CFU mL−1 | 563 |
GR | E. coli O157:H7 | EIS | 10–100 cells per mL | — | 564 |
Nanoporous alumina membrane/GR-QDs | Salmonella typhimurium | EIS | 1 pM to 100 nM | 1 pM | 565 |
Functionalized bridged rebar GR | E. coli O78:K80:H11 | EIS | 101 to 106 CFU mL−1 | 10 CFU mL−1 | 566 |
EC-rGO/CS nanocomposite | Salmonella enterica | DPV | 101 to 106 CFU mL−1 | 101 CFU mL−1 | 567 |
rGO/AuNPs/Ab2/IMB/SPCE | Salmonella pullorum | DPV | 102 to 106 CFU mL−1 | 89 CFU mL−1 | 568 |
rGO-azophloxine nanocomposite | S. typhimurium | 101 to 108 CFU mL−1 | 101 CFU mL−1 | 569 | |
ssDNA/GO/CS nanocomposite | E. coli O157:H7 | EIS | 10 pM to 10 nM | 3.584 pM | 570 |
AuNPs–PdNPs/EC-rGO | Lomefloxacin | SWV | 4–500 μM | 81 nM | 571 |
Amoxicillin | 3–350 μM | 9 μM | |||
3D GR nanosheet/AuNPs | Sulfate-reducing bacteria (SRB) | DPV | 0.1 μM to 10 fM | 9.41 fM | 572 |
GO/AuNPs | Cronobacter sakazakii | DPV | 2 × 102 to 2 × 107 CFU mL−1 | 2 × 101 CFU mL−1 | 573 |
rGO/polyethylenimine | E. coli UTI89 bacteria | DPV | 101 to 104 CFU mL−1 | 10 CFU mL−1 | 574 |
Food toxins | |||||
ss-HSDNA/rGO aerogel | Aflatoxin B1 (AFB1) | EIS | 0.1–70 ng mL−1 | 0.04 ng mL−1 | 575 |
Anti-AFB1/rGO/ITO | AFB1 | CV | 0.125–1.5 ng mL−1 | 0.12 ng mL−1 | 576 |
AuNPs/carboxylated rGO | AFB1 | EIS | 0.1–12 ng mL−1 | 0.1 ng mL−1 | 577 |
rGO/PPy/PPa nanocomposite | AFB1 | EIS | 10 fg mL−1 to 10 pg mL−1 | 10 fg mL−1 | 578 |
NiNPs/rGO nanosheets | Mycotoxin (AFB1) | CV | 1–8 ng mL−1 | 0.16 ng mL−1 | 579 |
GR–thionine–aptamer | Ochratoxin A | DPV | 0.4–8 ng mL−1 | 5.6 pg mL−1 | 580 |
DNA aptamer/GR | β-Lactoglobulin milk protein | SWV | 0–100 ng mL−1 | 20 pg mL−1 | 581 |
Metal ions | |||||
AuNPs/GR/cysteine composite | Cd2+ | SWASV | 0.5–40 μg L−1 | 0.1 μg L−1 | 582 |
Pb2 | 0.05 μg L−1 | ||||
GO modified Au electrode | Pb2+ | SWV | 0–50 ppb | 0.4 ppb | 583 |
Hg2+ | 0–15 ppb | 0.8 ppb | |||
Cu2+ | 0–200 ppb | 1.2 ppb | |||
GR nanodots/porous Au electrode | Pb2+ | SWV | 0.006–2.5 μM | 0.8 nM | 584 |
Cu2+ | 0.009–4 μM | 1 nM | |||
GO/AgNPs composite | Pb2+ | SWV | 0.1 nM to 10 μM | 80 pM | 585 |
Hollow AuPd-flower-like MnO2–hemin@rGO composite | Pb2+ | DPV | 0.1 pM to 200 nM | 0.034 pM | 586 |
DNA-modified 3D rGO/CS composite | Hg2+ | EIS | 0.1 nM to 10 nM | 0.016 mM | 587 |
AuNPs/rGO nanocomposite | Hg2+ | CV, EIS | 10 ng L−1 to 1.0 μg L−1 | 1.5 ng L−1 | 588 |
Heparin modified CS/GR composite | Pb2+ | SWASV | 1.125–8.25 μg L−1 | 0.03 μg L−1 | 589 |
rGO/AuNPs composite | Fe3+ | DPV | 30–3000 nM | 3.5 nM | 590 |
Pi-A/rGO nanocomposite | Cu2+ | SWASV | 5–300 μg L−1 | 0.67 μg L−1 | 591 |
Nile red-GR composite | Fe3+ | CV, DPV | 30–1000 μM | 24.9 μM | 592 |
rGO-CS/poly-l-lysine nanocomposite | Cd2+ | DPASV | 0.05–10 μg mL−1 | 0.01 μg mL−1 | 593 |
Pb2 | 0.02 μg mL−1 | ||||
Cu2+ | 0.02 μg mL−1 | ||||
GR-Au modified electrode | Hg2+ | CV, SWV | 1 aM to 100 nM | 0.001 aM | 594 |
Ruthenium(ii) bipyridine [Ru(bpy)3]2+ complex/GO composite | Cd2+ | CV, EIS | 0.5–0.3 μM | 2.8 nM | 595 |
Pb2+ | 0.05–0.25 μM | 1.41 nM | |||
As2+ | 0.05–1.8 μM | 2.3 nM | |||
Hg2+ | 0.1–1.2 μM | 1.6 nM | |||
l-Cysteine/AuNPs/rGO | Cu2+ | DPSV | 2–60 μg mL−1 | 0.037 μg mL−1 | 596 |
MnFe2O4/GO nanocomposite | Pb2+ | SWASV | 0.2–1.1 μM | 0.0883 μM | 597 |
GQDs@VMSF | Hg2+ | DPV | 10 pM to 1 nM | 9.8 pM | 598 |
Cu2+ | 10 pM to 1 nM | 8.3 pM | |||
Cd2+ | 20 nM to 1 μM | 4.3 nM |
Abbreviations used: MoS2: molybdenum disulfide, PANI: polyaniline, PPy: polypyrrole, PPa: pyrrolepropylic acid, GQDs: graphene quantum dots, LMF: lomefloxacin, AMX: amoxicillin, EIS: electrochemical impedance spectroscopy, SWV: square wave voltammetry, SWASV: square wave anodic stripping voltammetry, Ab2: secondary antibody, IMB: immunomagnetic beads, Pi-A: N-(2-(1-(p-tolyl)-1H-phenanthro[9,10-d]imidazol-2-yl)phenyl)picolinamide, DPASV: differential pulse anodic stripping voltammetry, ochratoxin A (OTA): (2S)-2-[[(3R)-5-chloro-8-hydroxy-3-methyl-1-oxo-3,4-dihydroisochromene-7-carbonyl]amino]-phenylpropanoic acid, VMSF: vertically ordered mesoporous silica-nanochannel film.
Tiwari et al.559 demonstrated an electrochemical sensor based on a GO-modified iron oxide-CS nanocomposite for pathogen detection. The sensor was fabricated through the covalent immobilization of E. coli O157:H7 as a specific probe oligonucleotide sequence on the nanocomposite films. The sensor showed a linear response to complementary DNA in 10−6 M to 10−14 M concentration range with an LOD of 1 × 10−14 M. Pandey et al.564 reported a graphene-based label-free biosensor for detecting pathogenic bacteria. Graphene was interfaced with interdigitated microelectrodes for designing a biosensor that was biofunctionalized using E. coli O157:H7-specific antibodies (Fig. 27). The capacitance change of the sensor showed the sensitivity of 10–100 cells per mL of the E. coli O157:H7 strain.
3.9. Detection of food toxins
Environmental conditions such as insect damage, temperature, and humidity may lead to increased infection and toxin accumulation. Mycotoxins are toxic secondary metabolites generated by fungi including Aspergillus flavus, Aspergillus parasiticus, Aspergillus ochraceus, Penicillium verrucosum that readily grow on crops such as cereals, nuts, dried fruits, and beans during plant growth, harvesting, drying, processing and storage. Hence, the efficient monitoring and detection of foodborne pathogens and toxins (sterigmatocystin, aflatoxin, ochratoxin, etc.) are of paramount significance.599 Although several methods have been developed to maintain the quality of food nutrients and to prevent contamination of food, still diseases due to foodborne pathogens have increased considerably. Food and water contamination by pathogenic microorganisms causes 1.8 million deaths per year worldwide.600 Aflatoxin-B1 (AFB1) is a highly toxic and carcinogenic compound generated by Aspergillus species of fungi. Among more than 20 aflatoxins, only four compounds, aflatoxin-B1 (AFB1), AFB2, AFG1, and AFG2, are classified as human carcinogens. AFB1 is more toxic relative to the other types of aflatoxins that cause human liver cancer.575 Various analytical techniques have been developed and applied for the fast, sensitive and selective detection of diverse toxins in foods and food products, including fluorescence and electrochemical sensing, colorimetry, immunoassays, and chromatographic separation.599 However, electrochemical methods are highly sensitive and easy for the detection of food toxins.601 Nanomaterials such as inorganic nanoparticles and carbon-based nanomaterials (CNTs, graphene) have been effectively used for the detection of food contaminants.602,603Table 8 summarizes the graphene-based biosensors for the detection of pathogens, food toxins, and metal ions.
Srivastava et al.576 demonstrated an electrochemical sensor by covalently binding monoclonal antibodies to AFB1 (anti-AFB1) onto the rGO surface for detecting food toxin (AFB1). The rGO/anti-AFB1 based sensor showed high sensitivity of 68 μA ng−1 mL cm−2 and an LOD of 0.12 ng mL−1. The same research group also reported a label-free sensor using a AuNP-supported rGO nanosheet, and the surface was bioconjugated with monoclonal antibodies against AFB1. The BSA/anti-AFB1/AuNPs/rGO nanocomposite-based immunosensor showed good stability up to 56 days and the detection of AFB1 with a sensitivity of 182.4 μA ng−1 mL cm−2 and a linear range of 0.1–12 ng mL−1 with an LOD of 0.1 ng mL−1.577 Moreover, this group also demonstrated the fabrication of label-free immunosensors that used rGO sheets decorated with antibody-conjugated nickel nanoparticles for the electrochemical detection of AFB1 mycotoxin.579 Owing to the high electrocatalytic activity of NiNPs, the fabricated BSA/anti-AFB1/rGO-NiNPs immunosensor exhibited an enhanced electron transfer rate and sensitivity of 129.6 μA ng mL−1 cm−2, a linear detection range of 1.0–8.0 ng mL−1 with an LOD of 0.16 ng mL−1 for AFB1 and stability up to 42 days. Krittayavathananon et al.575 showed an impedimetric biosensor for detection of the AFB1 level employing rGO aerogel labeled with ssDNA on a rotating disk electrode. The sensor detected AFB1 in a linear concentration range of 7 × 10−8 to 1 × 10−10 g mL−1 with an LOD of 0.04 ng mL−1. Wang et al.578 reported the detection of AFB1 using an rGO/polypyrrole/pyrrolepropylic acid nanocomposite-based impedimetric immunosensor. The sensor showed improved sensitivity for the detection of AFB1 in a linear range of 10 fg mL−1 to 10 pg mL−1. Kaur et al.604 developed an electrochemical aptasensor using functionalized GR (f-GR)-doped chitosan composite for detecting mycotoxin ochratoxin A (OTA). The fGR played a role in increasing the surface area of the electrode whereas CS hindered the leaching of aptamer (APT). The streptavidin (SA) attached in f-GR was immobilized by ATP molecules through SA-biotin coupling process. The APT/SA/CS-f-GR composite-based biosensor showed a linear range of 1 μg mL−1 to 1 fg mL−1, and an LOD of 1 fg mL−1 for standard sample and 0.01 ng mL−1 for spiked grape juice samples for the OTA detection with a response time of 8 min and retained 91.4%, 70.7% and 53.8% of initial responses after 7, 21, and 28 days, respectively. The OTA recoveries from the grape juice were found to be between 90% and 101%. Jiang et al.605 used AuNPs/rGO nanocomposite to amplify the electrochemical impedimetric signal of an aptasensor for mycotoxin ochratoxin A (OTA) detection within picomolar level sensitivity. The negative assembled reporter DNA covered almost the entire surface of the AuNPs/rGO nanocomposite and effectively repelled the [Fe(CN)6]4−/3− anions, which enabled considerable amplification for the detection of OTA. The designed sensor displayed a good response for OTA concentrations ranging from 1.0 pg mL−1 to 50 ng mL−1 with an LOD of 0.3 pg mL−1.
3.10. Detection of toxic heavy metal ions
Toxic heavy metal ions including of arsenic (As3+), lead (Pb2+), chromium (Cr3+ or Cr6+), cadmium (Cd2+), and mercury (Hg2+) may get accumulated in the human body through food chains. These highly toxic pollutants are non-biodegradable and may have adverse effects on the central nervous, immune and reproductive systems even at very low trace amounts.606 It is critical to develop new analytical techniques for monitoring toxic heavy metal ions in water, food and the environment.607 The electrochemical approach is a simple low-cost method and facilitates real-time monitoring of pollutants compared to other spectroscopic and optical techniques.608 Different types of nanostructured materials have been employed for effectively monitoring environmental pollutants. Graphene and its nanocomposites have shown great promise for removing toxic heavy metals and organic dyes from aqueous solutions.609,610 The graphene-based electrochemical sensors used for detecting various metal ions are summarized in Table 8.
Muralikrishna et al.611 utilized l-cysteine-functionalized GO for the simultaneous detection of Cd(ii), Cu(ii), Pb(ii), and Hg(ii) in the linear detection range of 0.4 to 2.0 μM for Cd2+, Cu2+ and Hg2+ and 0.4 to 1.2 μM for Pb2+. The l-cysteine/GO composite-based sensor showed LODs of 0.366, 0.261, 0.416 and 1.113 μg L−1 for Cd2+, Cu2+, Pb2+, and Hg2+, respectively. The limits of metal ion detection were found to be lower than the WHO standards. Gumpu et al.595 used a ruthenium(ii) bipyridine complex ([Ru(bpy)3]2+) and GO nanocomposite to detect Cd(ii), Pb(ii), As(iii) and Hg(ii) metal ions. The sensor showed the lowest detection limits of 2.8 nM for Cd(ii), 1.41 nM for Pb(ii), 2.3 nM for As(iii) and 1.6 nM for Hg(ii) metal ions. Zhang et al.612 reported the use of TiO2–graphene hybrid nanostructures for Pb(ii) and Cd(ii) detection. The sensor showed linear ranges from 1.0 × 10−8 M to 3.2 × 10−5 M and 6.0 × 10−7 M to 3.2 × 10−5 M and LODs of 1.0 × 10−10 M and 2.0 × 10−9 M for Pb2+ and Cd2+ respectively. Palanisamy et al.613 reported the electrochemical determination of Hg(ii) based on activated graphite-modified screen-printed carbon electrodes. The sensor exhibited a linear range of 0.05–14.77 ppm and an LOD of 4.6 ppb with a sensitivity of 81.5 mA ppm−1 cm−2. The LOD value is considerably below the guideline values for Hg(ii) in drinking water. Seenivasan et al.614 synthesized cysteine-functionalized GO that used carbonyldiimidazole as a cross-linker for the electrochemical detection of Pb2+ ions in water using DPV. The resulting sensor showed a linear range of 1.4–28 ppb with an LOD of 0.07 ppb (S/N = 3) for the detection of Pb2+ ions. This value is 2-fold lower than the 10 ppb threshold for drinking water set by WHO. Zhang et al.594 reported the activation of thymine–Hg2+–thymine (T–Hg2+–T) coordination chemistry for the detection of Hg2+ with an LOD of 0.001 aM using an electrodeposited graphene-Au-modified electrode for signal amplification. Fig. 28 shows a schematic illustration of the sensing approach for the detection of Hg2+, square wave voltammograms (SWV) of the biosensor as a function of Hg2+ ion concentration and its selectivity toward Hg2+ ions among various interfering metal ions and their mixture containing Hg2+ ions. In this sensor design, the electrodeposited GR-Au on a GCE surface is functionalized with a 10-mer thymine-rich DNA probe (P1), and the Au nanocarrier is functionalized with a 29-mer guanine-rich DNA probe (P3) labeled with MB to further improve the signal response. With the addition of Hg2+, the T–T mismatched dsDNA between P1 and a 22-mer thymine-rich DNA probe (P2) forms on the surface of the electrode because of T–Hg2+–T coordination chemistry and the introduction of the MB-nano-Au-P 3s for P2 hybridization. The SWV of the mercuric sensor showed a very broad range of Hg2+ ions concentration from 10 μm to 0.001 aM where the detection of Hg2+ ions ranged from 1.0 aM to 100 nM with an LOD of 0.001 aM. Furthermore, biosensor also showed very high selectivity toward Hg2+ ions among various interfering metal ions when measurements were performed by the square wave voltammetry using 10 nM of Hg2+ and 500 nM of K+, Ca2+, Ba2+, Cd2+, Cr2+, Co2+, Cu2+, Mg2+, Mn2+, Pb2+, Ni2+, Zn2+, Fe3+, Al3+, and their mixture with 10 nM of Hg2+ respectively, where the sensitivity of interfering metal ions were found be less than 5% compared with Hg2+ ions. Yu et al.615 reported a noncovalently modified rGO sensor for the detection of Hg2+ down to the picomolar concentration range. The resulting sensor could detect Hg2+ ions at low concentrations up to 0.1 nM, which is lower than the limits of the WHO and the United States Environmental Protection Agency (US EPA). Lu et al.598 developed electrochemical sensors for detecting Hg2+, Cu2+, Cd2+ ions and dopamine using silica nanochannel-confined GQDs. Fig. 29 shows DPV curves recorded with vertically ordered mesoporous silica-nanochannel film (VMSF)/ITO electrode, OH-GQD@VMSF/ITO and NH2-GQD@VMSF/ITO electrodes for the detection of Hg2+, Cu2+, and Cd2+. Both OH-GQD@VMSF/ITO and NH2-GQD@VMSF/ITO electrodes exhibited significantly amplified current signals for detecting Hg2+, Cu2+, and Cd2+ ions than that of VMSF/ITO electrode having no GQDs. This indicates that the significant increase in current signals is associated with the GQDs due to their molecular interactions with Hg2+, Cu2+, and Cd2+ ions, efficient electronic transfer between GQDs and metal ions as well as high specific surface area inherited by GQDs. DPV curves were also recorded as a function of different concentrations of Hg2+ and Cu2+ using OH-GQD@VMSF/ITO electrode and as a function of different concentrations of Cd2+ using NH2-GQD@VMSF/ITO electrode. The OH-GQD@VMSF/ITO electrode-based sensing platform could detect Hg2+ and Cu2+ ions at concentrations as low as 9.8 pM and 8.3 pM, respectively, compared with the LOD of 0.3 μM for Hg2+ and 32 nM for Cu2+ using VMSF/ITO electrode. Likely, the NH2-GQD@VMSF/ITO electrode showed an LOD of 4.3 nM for Cd2+ compared with 120 nM using VMSF/ITO electrode. The LOD for detecting Hg2+ was reduced by 5 orders of magnitude by incorporating OH-GQDs into the electrode. The ITO electrode was replaced by Au electrode, the resulting OH-GQD@VMSF/Au electrode showed a linear range of 200 nm to 100 μM and an LOD of 120 nm for the detection of dopamine. These GQD@VMSF/ITO electrode-based sensors also showed high sensitivity and selectivity toward Hg2+, Cu2+, and Cd2+ ions in presence of other interfering chemical analytes including Ca2+, Mg2+, Co2+, Fe3+, Cr3, BSA and hemoglobin. Similarly, the OH-GQD@VMSF/Au electrode-based sensor showed high selectivity toward dopamine in the presence of other interfering bioanalytes including common ions, amino acids, protein (concanavalin A), ascorbic acid and uric acid.
3.11. Detection of pesticides
Pesticides are widely employed in agriculture to control weeds and pests and to increase food production around the world. Herbicides and insecticides used to protect plants can be potentially toxic to human. Their overuse and improper disposal can cause significant food and environmental contamination as pesticides easily dissolve in water and do not decompose easily so they may have harmful health effects.616 Therefore, it is important to develop biosensors for the sensitive detection of agro-hazardous pesticide residues in food and water to avoid toxic effects to humans. Organophosphorus pesticides (OPs) are used as insecticides to protect crops worldwide, but they are equally unsafe to public health due to their high neurotoxicity.617 Acetylcholinesterase (AChE), a kind of acetylhydrolase, is a catalytic enzyme present in the central nervous system that catalyzes the hydrolysis of neurotransmitters such as acetylcholine and choline esters. AChE inhibitor-based drugs have been approved by the FDA for clinical trials and the management of Alzheimer disease, which is a neurodegenerative disorder.618–620 The catalytic activity of AChE is significantly inhibited by exposure to trace amounts of environmentally toxic OPs and OP nerve agents.621–623 This catalytic inhibition concept has been used to develop various types of AChE-based biosensors for detecting OPs.624–627 AChE can be easily immobilized on the surface of nanostructured materials to improve the sensitivity of biosensors for detecting pesticide residues.628–634 Graphene-based materials also offer high surface area and plentiful active sites; therefore, they have been used for developing AChE inhibition biosensors.
Two-dimensional layered nanomaterials analogous to graphene635 and transition metal dichalcogenides (TMDs)636 have attracted significant research interest for developing biosensors for the electrochemical detection of pesticides. Owing to its high surface area and unique electrocatalytic properties, graphene can markedly enhance biosensing performance (Table 9). AChE electrochemical biosensors with graphene nanocomposite-modified GCEs have been studied for the detection of different types of pesticides: methyl parathion, carbofuran,637 chlorpyrifos,638–640 imidacloprid,641 methyl parathion,642 phoxim with graphene/GCE,643 poly(3-methylthiophene)/nitrogen-doped graphene (P3MT/N-GR),644 and carboxylic chitosan (CChit)/silver nanoclusters-rGO (AgNCs-rGO),645 paraoxon and chlorpyrifos with TiO2-GO/UiO-66 composite,646 carbaryl with MWCNTs/GO nanoribbons,647 carbaryl and chlorpyrifos with AgNPs–CGR/NF composite,648 chlorpyrifos and carbofuran with ZnONPs–CGR/NF composite,649 carbaryl and monocrotophos with ionic liquid-functionalized graphene (IL-GR)/gelatin,650 monocrotophos with Prussian blue nanocubes (PBNCs)/rGO,651 malathion and carbaryl with rGO-AuNP/β-cyclodextrin/Prussian blue-CS nanocomposites (rGO-AuNPs/β-CD/PB-Chit),652 dichlorvos with multilayered Chit@TiO2-Chit/rGO,653 fenitrothion with cerium oxide nanoparticle-decorated rGO (CeO2-rGO),654 diuron with rGO-AuNPs,655 paraoxon-ethyl with rGO-AuNPs/polypyrrole (PPy),656 carbaryl with GR/PANI,657 carbaryl with an electrochemically induced porous GO network,658 methyl parathion and malathion with plant esterase (PLaE)–Chit/AuNPs–graphene nanosheets (PLaE–Chit/AuNPs–GNs).659
Graphene nanocomposite-modified glassy carbon electrode (GCE)-based acetylcholinesterase (AChE) electrochemical biosensors for detecting pesticidesa.
Graphene-based nanocomposites | Pesticides | Linear range | Limit of detection | Ref. |
---|---|---|---|---|
PtNPs–carboxylic GR–Nafion | Methyl parathion | 1 × 10−7 to 1 × 10−2 μM | 5 × 10−5 nM | 637 |
PtNPs–carboxylic GR–Nafion | Carbofuran | 1 × 10−6 to 1 × 10−2 μM | 5 × 10−4 nM | 637 |
NiONPs–carboxylic GR–Nafion | Methyl parathion | 1 × 10−7 to 1 × 10−2 μM | 5 × 10−5 nM | 638 |
NiONPs–carboxylic GR–Nafion | Chlorpyrifos | 1 × 10−6 to 1 × 10−2 μM | 5 × 10−4 nM | 638 |
SnO2NPs–carboxylic GR–Nafion | Methyl parathion | 1 × 10−7 to 1 × 10−2 μM | 5 × 10−5 nM | 639 |
SnNPs–carboxylic GR–Nafion | Chlorpyrifos | 1 × 10−6 to 1 × 10−2 μM | 5 × 10−4 nM | 639 |
MIPs/rGO-AuNPs | Carbofuran | 5.0 × 10−2 to 0.2 μM | 2.0 × 10−2 μM | 640 |
MIPs-GR | Imidacloprid | 0.5–15 μM | 0.10 μM | 641 |
EC-rGO/Nafion | Methyl parathion | 0.002–0.7 μM | 1 nM | 642 |
GR/GCE | Phoxim | 20–20 000 nM | 8 nM | 643 |
Poly(3-methylthiophene)/N-doped GR | Phoxim | 0.02–2.0 μM | 6.4 nM | 644 |
Carboxylic chitosan/AgNCs-rGO composite | Phoxim | 0.2–250 nM | 81 pM | 645 |
TiO2-GO/UiO-66 composite | Paraoxon | 1.0–100 nM | 0.2 nM | 646 |
Chlorpyrifos | 5.0–300 nM | 1.0 nM | ||
MWCNTs/GO nanoribbons | Carbaryl | 5–5000 nM | 1.7 nM | 647 |
AgNPs–carboxylic GR/Nafion | Carbaryl | 1.0 × 10−6 to 1 × 10−2 μM | 5.45 × 10−4 nM | 648 |
AgNPs–carboxylic GR/Nafion | Chlorpyrifos | 1.0 × 10−7 to 1 × 10−2 μM | 5.3 × 10−4 nM | 648 |
ZnONPs–carboxylic GR/Nafion | Chlorpyrifos | 1.0 × 10−7 to 1 × 10−2 μM | 5.0 × 10−5 nM | 649 |
ZnONPs–carboxylic GR/Nafion | Carbofuran | 1.0 × 10−6 to 1 × 10−2 μM | 5.2 × 10−4 nM | 649 |
Il–GR–gelatin | Carbaryl | 1.0 × 10−8 to 1 × 10−2 μM | 5.3 × 10−6 nM | 650 |
Il–GR–gelatin | Monocrotophos | 1.0 × 10−7 to 5 × 10−2 μM | 4.6 × 10−5 nM | 650 |
PBNCs-rGO composite | Monocrotophos | 1.0–600 ng mL−1 | 0.1 ng mL−1 | 651 |
rGO-AuNPs/β-CD/PB-CS | Malathion | 7.98 to 2.0 × 103 pg mL−1 | 4.14 pg mL−1 | 652 |
rGO-AuNPs/β-CD/PB-CS | Carbaryl | 4.3 to 1.0 × 103 pg mL−1 | 1.15 pg mL−1 | 652 |
CS@TiO2-CS/rGO | Dichlorvos | 0.036–22.6 μM | 29 nM | 653 |
CeO2-rGO composite | Fenitrothion | 0.025–2.0 μg mL−1 | 3.0 ng mL−1 | 654 |
rGO-AuNPs composite | Diuron | 0.5–30.0 μg mL−1 | 0.125 μg mL−1 | 655 |
rGO-AuNPs/PPy composite | Paraoxon-ethyl | 1.0 nM to 5 μM | 0.5 nM | 656 |
GR/PANI composite | Carbaryl | 38–194 ng mL−1 | 20 ng mL−1 | 657 |
Porous GO | Carbofuran | 0.3–6.1 ng mL−1 | 0.15 ng mL−1 | 658 |
PLaE–CS/AuNPs–GR | Methyl parathion | 0.19–760 nM | 0.19 nM | 659 |
PLaE–CS/AuNPs–GR | Malathion | 1.5–1513.5 nM | 1.51 nM | 659 |
EC-rGO-Nafion | Dichlorvos | 5–100 ng mL−1 | 2 ng mL−1 | 660 |
3D GR/MWCNTs composite | Carbaryl paraoxon | 0.3–0.81 ng mL−1 | 0.015 ng mL−1 | 661 |
0.05–1 ng mL−1 | 0.025 ng mL−1 | |||
Ionic liquid–GR/CO3O4/CS | Dimethoate | 5 × 10−3 nM to 0.1 μM | 1 × 10−4 nM | 662 |
Abbreviations used AChE: acetylcholinesterase, GCE: glassy carbon electrode, PLaE: plant esterase, GNs: graphene nanosheets, AuNPs: gold nanoparticles, carboxylic graphene (C-GR), Nafion (NF), PtNPs: platinum nanoparticles, NiONPs: nickel oxide nanoparticles, SnO2NPs: tin oxide nanoparticles, MIPs: molecularly imprinted polymers, C-CS: carboxylic chitosan, MWCNTs: multiwalled carbon nanotubes, Il-GR: ionic liquid-functionalized graphene, rGO: reduced graphene oxide, β-CD: β-cyclodextrin, PBNCs: Prussian blue nanocubes, CeO2: cerium oxide, PPy: polypyrrole, PANI: polyaniline, methyl parathion: O,O-dimethyl-O-(4-nitrophenyl) phosphorothioate.
An electrochemical AChE biosensor using rGO/silver nanoclusters (AgNCs)/chitosan composite was fabricated by Zheng et al.645 The immobilization of AChE on a GCE modified with rGO and AgNCs was accomplished using carboxylic chitosan as a cross-linking agent. The biosensor exhibited a wide linear range of 0.2–250 nM and an LOD of 81 pM for phoxim with S/N = 3. Bao et al.659 developed a sensor using plant esterase–chitosan/AuNPs–graphene nanosheets for the detection of methyl parathion and malathion. Esterase is a plant enzyme that dissociates esters into acid and alcohol components and catalyzes OPs with a similar mechanism to that of the AChE enzyme. The nanostructures of graphene nanosheets, AuNP-GNs, and PLaE–Chit/AuNP-GN nanocomposites were characterized using SEM and TEM. AuNPs approximately 13 nm in diameter were uniformly distributed on the crumpled GN surfaces. The particles of PLaE and CS nanocomposite were clearly visible on the AuNP-GN composites, where TEM images confirmed the formation of hybrid composites suitable for detecting OPs. The nanocomposite-based biosensor showed detection limits of 0.19 nM (50 ppt) for methyl parathion and 1.51 nM (0.5 ppb) for malathion (S/N = 3). The biosensor also exhibited high selectivity because no interference from other analytes, such as glucose, citric acid, metal ions and oxygen-containing inorganic ions, was observed. The specificity of the sensor was evaluated for the detection of OPs by comparing the normalized signal of 0.1 M PBS buffer solution (pH 6.5) containing 0.5 mM 1-naphthyl acetate in 10 ppb of methyl parathion (100%) with the normalized signals recorded in the presence of methyl parathion in combination with different interfering analytes (Fig. 30). The DPV data did not show any significant changes in the normalized signals for the presence of (c) 10 ppb lindane, (d) 1 ppm Fe3+, (e) 1 ppm Zn2+, (f) 1 ppm Cu2+, (h) 1 ppm K+, (i) 1 ppm NO3−, (j) 1 ppm PO43−, (k) 1 ppm SO42−, (l) 0.5 mM glucose, and (m) 0.5 mM citric acid after mixing with 10 ppb of methyl parathion. Interference with the 10 ppb methyl parathion was observed only with (b) 10 ppb of carbendazim and (g) 1 ppm Pb2+ with detection of 85.97 and 78.37%, respectively. The biosensor also showed storage stability, as no decrease in the normalized signal was observed after 9 days, and 73% of the initial signal was retained after 15 days.
Hondred et al.663 developed an electrochemical sensor with Pt nanoparticles electrodeposited on patterned graphene electrodes (PGEs) for detecting OPs. The electrode was first fabricated via inkjet maskless lithography (IML) followed by the electrodeposition of Pt nanoparticles to enhance its surface area, electrical conductivity, and electrocatalytic activity. Next, the enzyme phosphotriesterase was conjugated using the bifunctional cross-linking molecule glutaraldehyde (GA), as shown in Fig. 31. The fabricated PtNP–IML–PGE/GA biosensor showed rapid detection of paraoxon pesticide with 5 s response time, a sensitivity of 370 nA μM, a linear range of 0.1–1 μM, and an LOD of 3 nM. In comparison, the biosensor based on IML–PGE/GA (without PtNPs) showed a sensitivity of 270 nA μM, a linear range of 0.1–1 μM, and an LOD of 12 nM. The PtNP–IML–PGE/GA biosensor showed reusability over 12 repeated operations by retaining 95% sensitivity and 70% stability of anodic current signal to paraoxon after 8 weeks. The biosensor exhibited high selectivity toward paraoxon detection against interfering chemical nerve agents including p-nitrophenol, chlorpyrifos methyl, parathion, dichlofenthion, fenitrothion, phoxim, and dimethoate. These PtNP–IML–PGEs biosensors can be manufactured in large quantities at a low-cost and used in-field for detecting pesticides and other biochemical agents in river water, tap water and soil samples.
4. Graphene-based fluorescent biosensors
Fluorescence-based biosensing is a well-established optical tool with many advantages, such as high sensitivity, rapid detection time and easy operation, making it an ideal platform for biological, biochemical and medical research.664 The development of fluorescent biosensors to detect different biological molecules, such as glucose, H2O2, dopamine, NAs, food toxins and metal ions, is of great interest to medicine since this technique can provide direct readouts of molecular localization in different biological organisms and living cells. Since the discovery of green fluorescent protein (GFP), which enabled the observation of molecular interactions within a 10 nM range through the Förster resonance energy transfer (FRET) mechanism, a wide variety of fluorescent biosensors have been developed utilizing different types of nanomaterials with high sensitivity and selectivity, and low detection limits.665 Specifically, carbon-based nanomaterials such as GR or GO have been found to quench fluorescence very effectively, which makes them strong acceptors in the FRET process over the entire visible region. In addition, further functionalization with carboxyl (–COOH) groups has been applied to fluorescent sensors in order to attain high fluorescence quenching and ssDNA interaction through π–π stacking.21 GO has been found to exhibit high florescence quenching up to a distance of 300 Å.666
Graphene-based fluorescence quenching has been predominantly accredited to FRET due to the linear dispersion of Dirac electrons and the relatively distant effective gap between fluorescent molecules and graphene.667 The linear dispersion of Dirac fermions allows electron–hole pairs in graphene to resonate with photons of various frequencies that are emitted from fluorescent molecules. This kind of FRET mechanism and the high-efficiency quenching ability of graphene for all types of fluorophores makes GO promising for the development of new fluorescent-based biological sensors and other devices for their use in vivo and in vitro.21,462,668 Moreover, the amphiphilicity of GO facilitates the adsorption of diverse biomolecules on its surface due to its high binding affinity with biomolecules via π–π stacking.669 GO nanosheet shows the capability of efficient energy transfer when the adsorbed biomolecules are conjugated with a fluorescent dye, yielding fluorescence quenching with minimal background signal because of the absence of graphene's energy bandgap and the existing close-distance π–π stacking. The progress made in fluorescence-based biosensors have been discussed.17,21,128 The graphene- and graphene-nanocomposite-based fluorescent biosensors for the detection of various biomolecules are summarized in Table 10.
Graphene-based fluorescent biosensors for detecting biomolecules, nucleic acids, biomarkers, pathogens, food toxins, metal ions and pesticidesa.
Biosensor type | Graphene-based nanocomposites | Target | Linear range | Limit of detection (LOD) | Ref. |
---|---|---|---|---|---|
Biomolecules | Tyramine-functionalized GQDs | Glucose | 50 nM to 2 μM | 7.2 nM | 670 |
Tyramine-functionalized GQDs | H2O2 | 1 nM to 150 nM | 0.32 nM | 670 | |
Tyramine-functionalized GQDs | Cholesterol | 80 nM to 10 μM | 1.2 nM | 670 | |
Tyramine-functionalized GQDs | l-Lactate | 200 nM to 25 μM | 47 nM | 670 | |
Tyramine-functionalized GQDs | Xanthene | 100 nM to 18 μM | 32 nM | 670 | |
PVA/GQDs | Glucose | 0.25–24 mM | 10 μM | 671 | |
PVA/GQDs | H2O2 | 0.05–35 mM | 1.0 μM | 671 | |
GLY-GQDs | Ce4+ | 0.03–17.0 μM | 25 nM | 672 | |
Nucleic acids | GO | miRNA | 0.02–100 fM | 3 fM | 673 |
GO | miRNA | 10 fM to 10 pM | 3 fM | 674 | |
rGO | Hepatitis B virus (HBV) | 0.05 pg mL−1 to 1 ng mL−1 | 0.05 ng mL−1 | 675 | |
Biomarkers | GQDs | Cardiac marker antigen troponin I (cTnI) | 0.001–1000 ng mL−1 | 0.192 pg mL−1 | 676 |
GR | PSA | 100–500 ng mL−1 | 100 ng mL−1 | 677 | |
Pathogens | GQDs/AuNPs | S. aureus | 100 pM to 100 nM | 1 nM | 678 |
GR magnetic nanosheets/CS | P. aeruginosa | 4.5 × 102 to 5 × 102 CFU mL−1 | 5 CFU mL−1 | 679 | |
S. aureus | 4.5 CFU mL−1 | ||||
GR sheets | Oxytetracycline | 0.01–0.2 μM | 0.01 μM | 680 | |
GO/nucleic-acid stabilized Ag nanoclusters hybrid | DNA | 0–1000 nM | 0.5 nM | 681 | |
ATP | 2.5 nM | ||||
Thrombin | 0.5 nM | ||||
Food toxins | GO/UC NPs | Ochratoxin A (OTA) | 0.05–100 ng mL−1 | 0.02 ng mL−1 | 682 |
Aflatoxin B1 (AFB1) | 0.1–500 ng mL−1 | 0.1 ng mL−1 | |||
GO | OTA | 2.0–35 μM | 1.9 μM | 683 | |
CdTe QDs/GO | AFB1 | 3.2 nM to 320 μM | 1 nM | 684 | |
GQDs | OTA | 0.05–20 ng mL−1 | 13 pg mL−1 | 685 | |
GO/Au nanocomposite | AFB1 | 0.1–10 pg mL−1 | 0.03 pg mL−1 | 686 | |
Metal ions | GR/DNAzymes complex | Cu2+ | 0–250 nM | 2 nM | 687 |
GR/DNAzyme | Cu2+ | 0.01–1.5 μM | 0.365 nM | 688 | |
GR/DNAzyme | Pb2+ | 0.5 nM to 2 μM | 0.5 nM | 689 | |
GQDs/DNA | Hg2+ | 1 nM to 10 μM | 0.25 nM | 690 | |
GO/guanine-quadruplex DNA aptamer | Pb2+ | 0.75/6.0 nM L−1 | 0.40 nM L−1 | 691 | |
CdSe/ZnS QDs/GO | Pb2+ | 0.1–10 nM | 90 pM | 692 | |
GO | Hg2+ | 1–50 nM | 0.92 nM | 693 | |
GQDs | Cu2+ | 0–15 μM | 0.226 μM | 694 | |
GQDs/GO | Pb2+ | Up to 400 nM | 0.6 nM | 695 | |
Carbon dots/ODN/GO | Hg2+ | 5–200 nM | 2.6 nM | 696 | |
Dopamine/GQDs | Fe3− | 20 nM to 2 μM | 7.6 nM | 697 | |
GO-AuNPs | Pb2+ | 2 nM to 0.23 μM | 0.1 nM | 698 | |
Macroporous GR foam | Pb2+ | 50–500 pM | 50 pM | 699 | |
Cu2+ | 0.6 nM | ||||
GQDs | Fe3− | 0 to 60 μM | 0.45 μM | 700 | |
Pi-A/rGO | Cu2+ | 5–300 μg mL−1 | 0.67 μg mL−1 | 591 | |
N-doped GQDs | Al3+ | 2.5–75 μM | 1.3 μM | 701 | |
S-doped GQDs | Ag+ | 0.1–130 μM | 30 nM | 702 | |
GQDs | Cu2+ | 0.1–1 μM | 0.067 μM | 703 | |
GQDs/AuNPs | Pb2+ | 50 nM to 4 μM | 16.7 nM | 704 | |
N-doped GQDs | Hg2+ | 2–200 nM | 0.32 nM | 705 | |
Pesticides | N-doped GQDs | Omethoate | 0.1–1.7 nM | 0.041 pM | 706 |
N-doped GQDs MIP | Thiacloprid | 0.1–10 mg L−1 | 0.03 mg L−1 | 707 |
Abbreviations used PVA: poly(vinyl alcohol), PSA: (prostate specific antigen, a cancer marker), GLY: glycine, AFB1: aflatoxin B1, cTnI: cardiac marker antigen troponin I in blood, ATP: adenosine triphosphate, Pi-A: N-(2-(1-(p-tolyl)-1H-phenanthro[9,10-d]imidazol-2-yl)phenyl)picolinamide, CDs: carbon dots, ODN: oligodeoxyribonucleotide, MIP: molecularly imprinted polymer. Upconversion fluorescent NPs: BaY0.78F5:Yb0.2,Er0.02 and BaY0.78F5:Yb0.7,Tm0.02 nanoparticles.
4.1. Fluorescent detection of glucose, cholesterol, H2O2, and dopamine
Graphene-based nanocomposites have been widely applied to the fluorescence-based detection of glucose, H2O2, DA, and so forth, with enhanced sensitivity and selectivity (Table 10). Li et al.670 developed tyramine (TYR)-functionalized GQDs (TYR-GQDs) for fluorescent biosensing of H2O2 and four metabolites including glucose, cholesterol, l-lactate, and xanthine in the blood. In the TYR-GQDs conjugate, the tyramine is covalently attached on the surface of GQDs through the reaction between the amino (–NH2) groups of TYR and carboxyl (–COOH) groups of GQDs. In order to detect these four metabolites, their corresponding oxidases such as glucose oxidase, cholesterol oxidase, l-lactate oxidase, and xanthine oxidase were added into the 10 mM PBS (pH 7.0) containing 0.1 mg mL−1 TYR-GQDs conjugate to trigger photoluminescence (PL) quenching. Fig. 32 shows a schematic of fluorescence biosensing using TYR-GQDs, and PL spectra of 0.1 mg mL−1 TYR-GQDs conjugate in PBS containing 2.5 μM glucose oxidase, 10 μM cholesterol oxidase and 5 μM l-lactate oxidase at different concentrations of glucose, cholesterol and l-lactate, respectively. The TYR-GQD-based fluorescence biosensors exhibited LODs of 7.2 × 10−9 M, 3.2 × 10−10 M, and 1.2 × 10−9 M with linear ranges of 5 × 10−8 to 2 × 10−6 M, 1 × 10−9 to 1.5 × 10−7 M, and 8 × 10−8 to 1 × 10−5 M for glucose, H2O2 and cholesterol detection, respectively. The biosensor showed a linear range of 2 × 10−7 to 2.5 × 10−5 M and 1 × 10−7 to 1.8 × 10−5 M with LOD of 4.7 × 10−8 M and 3.2 × 10−8 M for l-lactate and xanthine detection, respectively. The evident PL quenching was not observed for TYR-GQDs after adding either glucose oxidase or glucose and other interferents such as fructose, lactose and maltose mixed with glucose oxidase, indicating high selectivity of the biosensor toward glucose detection. These TYR-GQD-based fluorescence biosensors showing high sensitivity and selectivity, can be used for healthcare for diagnosis of metabolic and other related diseases.
Chen et al.708 demonstrated a GO-based label-free near infrared (NIR) fluorescent sensor for detecting dopamine. The good affinity of DA molecules with GO allows multiple noncovalent interactions. The effective quenching of GO when DA molecules are adsorbed onto the GO nanosheet enables biosensing by way of direct readout of the NIR fluorescence of the GO in the NIR for the effective detection of DA. The sensor showed an LOD of 94 nM and a 2.0% relative standard deviation; it was used to DA determination in biological fluids with 98 to 115% quantitative recovery. Cheng et al.709 demonstrated a label-free FRET-based biosensor using doxorubicin (DOX)-functionalized GO for detecting DA in human serum, aqueous solutions and cells. The fluorescence is quenched upon adsorption onto GO. Upon the addition of DA, the preadsorbed DOX is released by the specific interaction occurring between DA and GO due to the significantly higher binding affinity of DA molecules, which recovers the fluorescence of DOX and enables selective sensing of DA. The fluorescent DOX-GO sensor showed a high response for the detection of DA in the 8.3 × 10−7 M to 3.3 × 10−5 M concentration range an aqueous solution and 1.44–11.48 μmol L−1 in a human serum sample. A linear relationship was observed between the ratio of fluorescence intensity (F0/F) of DOX before and after adding GO as a function of the GO concentration over 0.5 to 20 μg mL−1 range at 598 nm.
4.2. Fluorescence detection of nucleic acids
Fluorescence-based detection has become an attractive research area for a wide range of applications. It is suitable for NA sensors where the target-triggered conformational change of an oligonucleotide affects the fluorescence of DNA-binding dyes such as OliGreen, TOTO, and ethidium bromide.11 Carbon nanomaterials functionalized with carboxyl (–COOH) groups have been commonly used in NA sensors, which offer great fluorescence quenching and interaction with ssDNA via π–π stacking. Specifically, graphene and GO-based fluorescent sensors have been widely employed for the detection of biologically active molecules such as DNA, RNA, and proteins.21,602 Most of these biosensor designs involve the use of DNA as the basis for templates for targeted molecule recognition and reporting. These DNA segments including aptamers have been used for the selective binding of target analytes or as enzyme substrates and the signal transducer is graphene or GO. Moreover, many fluorescent nanomaterials such as QDs, nanoclusters (NCs), and upconversion nanoparticles (UCNPs) have been developed for their use in biosensing.
Xing et al.710 demonstrated a fluorescence aptasensor using a dsDNA/GO complex through dsDNA and GO binding in the presence of certain salts to study exonuclease I (Exo I) activities. In this sensing probe, the competitor gets hybridized with the aptamer in the absence of the target, which hinders the absorption of the competitor by Exo I, therefore, the formed dsDNA is adsorbed onto the surface of GO, giving rise to fluorescence quenching. On the other hand, the aptamer prefers binding with its target after the target is introduced into the system; this results in a nuclease reaction, and a minor change in fluorescence is observed when GO is introduced because of the weak affinity between generated mononucleotides and GO. A smaller dissociation constant (Kd) value of 311.0 μM and an LOD of 3.1 μM were obtained for dsDNA and GO-based fluorescence aptasensor, compared with the conventional dye-labeled aptamer and GO complex-based sensing platform (Kd = 688.8 μM and LOD = 21.2 μM). Chen et al.711 demonstrated a nitrogen- and sulfur-codoped rGO (N,S-rGO) as a sensing probe for the fluorescent detection of various biological species through simple fluorescence quenching and recovery (Fig. 33A). Doping with N and S heteroatoms can effectively activate the sp2-hybridized carbon lattice, which greatly improves the electron/energy acceptor. The QD fluorescence was found to be quenched after mixing QD-labeled with human disease-related genes such as hepatitis B virus (HBV) DNA and HIV DNA molecular beacon probes with N,S-rGO; the recovery of QD fluorescence was observed after adding target HBV and HIV DNA. The biosensor showed the target virus DNA with an LOD of 2.4 nM with a linear range of 5–100 nM for HBV and 3.0 nM with a linear range of 7–80 nM for HIV. The molecular beacon probes with thrombin and immunoglobulin (IgE) aptamers showed LODs of 0.17 ng mL−1 for thrombin and 0.19 ng mL−1 for IgE proteins. The N,S-rGO-based QD sensor showed 99 to 100.6% quantitative recovery. Zhang et al.712 showed a fluorescence biosensor using GQDs and pyrene-functionalized molecular beacons (py-MBs) for detecting miRNAs (Fig. 33B). Pyrene was used to functionalize and trigger specific FRET between GQDs and py-MBs containing fluorescent dyes and the target detection was realized by the change in fluorescence intensity. The biosensor showed a linear range of 0.1 nM to 200 nM with LOD of 100 pM and high selectivity for the detection of target miRNA miR-155 in the presence three other interfering miRNAs including miR-21, miR-210, and miR-196a.
Metal nanoclusters such as Ag nanoclusters (NCs) also show promise for greatly enhanced detection limits and sensitivity of fluorescence-based biosensors. Metal NCs can either increase or quench fluorophore emission, depending on the distance between a metal surface and the resulting molecular orientation. Liu et al.681 developed a fluorescent DNA sensor and aptasensor for the detection of infectious pathogens based on a silver nanocluster/GO hybrid system (Fig. 33C). By conjugating oligonucleotide sequences to NA-protected AgNCs, the fluorescence was generated by the desorption of AgNCs from GO surface by forming duplex DNA structures or complexes with aptamer-substrate. This approach enabled thrombin detection with an LOD of 0.5 nM. The hybrid biosensor was also used for the detection of HBV, HIV, and Treponema pallidum (syphilis) genes. The upconversion nanoparticle-based FRET detection approach has attracted significant research interest. Alonso-Cristobal et al.713 reported a highly sensitive DNA biosensor based on FRET pairing between erbium- and ytterbium-doped β-NaYF4 (NaYF4:Yb,Er) UCNP fluorescent donors and GO quencher (Fig. 33D). In this sensing probe, the DNA-functionalized NaYF4:Yb,Er@SiO2 nanoparticles were near the GO surface, and FRET fluorescence quenching was induced by the π–π stacking interactions occuring between the GO and nucleobases of the DNA because of the fluorescence emission overlapping of NaYF4:Yb,Er@SiO2 NPs and the GO absorption spectrum. This nanoparticle-mediated upconversion approach showed high sensitivity with an LOD of 5 pM. Huang et al.714 designed a FRET-based biosensor from DNA-functionalized NaYF4:Yb,Tm@NaYF4 UCNPs utilizing liquid–liquid interface-based ligand exchange. The resulting biosensor exhibited a high sensitivity with an LOD of 1 × 10−4 U mL−1 for S1 nuclease.
4.2.1. Amplified detection of nucleic acids
There has been significant effort to enhance the signal intensity in order to detect the trace amounts of bioanalytes. Numerous strategies have been developed for signal enhancement, including ligation chain reaction (LCR), polymerase chain reaction (PCR), and rolling circle amplification (RCA).128,715 RCA offers the capability of creating DNA products through a replication process that may contain thousands of tandem sequence repeats; therefore, RCA is a powerful tool for signal amplification. Numerous reports utilizing this unique strategy have appeared (see Table 11) to enhance the sensitivity of the detection of biomolecules.443
Graphene-based signal enhancement strategies.
Graphene-based platform | Amplification method | Target | Linear range | Limit of detection | Ref. | |
---|---|---|---|---|---|---|
GR | Rolling circle amplification | Nucleic acid | DNA | 10 pM | 10–200 pM | 716 |
GO | Rolling circle amplification | Nucleic acid | miRNA | 1 fM to 50 pM | 0.4 pM | 717 |
GR | Hybridization chain reaction | Nucleic acid | miRNA | 10–2000 fM | 4.2 fM | 718 |
Au nanoclusters/GR hybrid | Exo III-aided cascade target recycling | Nucleic acid | DNA | 0.02 fm to 20 pM | 0.057 fM | 401 |
GO | Hybridization chain reaction | Nucleic acid | RNA | 5 pM to 12 nM | 2.7 pM | 719 |
GR | Hybridization chain reaction | Nucleic acid | miRNA | 100 pM to 10 nM | 100 fM | 720 |
GO | Isothermal exponential amplification | Nucleic acid | miRNA | 10 fM to 10 pM | 3 fM | 674 |
rGO | In situ reverse transcription | Nucleic acid | miRNA | 10 fM to 100 pM | 1.318 pM | 721 |
GO | Nicking enzyme signal amplification | Protein | Thrombin | 2 fM to 200 nM | 1.0 fM | 722 |
GO | DNase I-mediated cyclic signal amplification | Bacteria | S. Paratyphi A | 1 × 102 to 1 × 1011 cells per mL | 1 × 102 cells per mL | 723 |
GO | Hybridization chain reaction | Small molecule | Biothiol | 0.1–1000 nM | 0.1 nM | 724 |
GO | GO-assisted rolling circle amplification | Pathogen | Ebola virus | 30 fM to 3 nM | 1.4 pM | 725 |
GO–AuNCs | HCR | Food toxin | AFB1 | 0.1–10 pg mL−1 | 0.03 pg mL−1 | 686 |
GO | Hybridization chain reaction | Metal ion | Hg2+ | 0–1 nM | 0.3 nM | 602 |
GR | GR/DNAzyme | Metal ion | Pb2+ | Up to 100 nM | 300 pM | 726 |
Liu et al.716 developed a sensor using graphene for the detection of DNA probes, through an RCA signal-amplified technique. The working mechanism of this rGO-aptamer RCA strategy is displayed in Fig. 34A. The sensing design consists of an ssDNA probe and an rGO transducing mediator in order to amplify the molecular detection. Specifically, the sensing probe is designed with 2 sequence domains: a 3′ primer domain that initiates RCA and a 5′ domain consisting of an aptamer for molecular recognition (Fig. 34B). The rGO surface adsorbs the ssDNA probe via π–π stacking, preventing the probe's primer region from being used for RCA initiation. The adsorbed probes undergo conformational change in the presence of any targeted molecule, releasing the probes from the surface of the rGO, exposing the primer domain for RCA. The detection of the target was therefore, in effect, used for the detection of the products of the RCA. This RCA approach showed the detection of ATP and DNA with LODs as low as 60 nM and 0.8 pM, respectively. Hong et al.717 developed a GO-based biosensor combined with the target-specific RCA technique for the fluorometric detection of miRNA. By utilizing this approach, the resulting sensor exhibited a highly enhanced quantitative analysis of miRNA with an LOD as low as 0.4 pM. Wen et al.725 demonstrated a GO-assisted RCA probe for the sensitive detection of Ebola virus (EBOV). No RCA products were obtained in the absence of the EBOV gene; however, the fluorescence quenching of fluorescein amidate (FAM) was observed when FAM-labeled detection probe was adsorbed on the GO surface. The sensor showed high performance both in aqueous solution and in 1% serum for determination of the EBOV gene with an LOD of 1.4 pM.
Special types of enzymes consisting of DNA, also known as DNAzymes, have been developed to perform various catalytic functions as an alternative to traditional protein enzymes.727 Since the first report on DNAzyme by Breaker and Joyce727 in 1994, numerous DNAzyme sequences have been discovered, showing high catalytic activities in various chemical reactions. DNAzymes can readily interact with various fluorescent tags, functional molecules and solid surfaces, which facilitate the highly sensitive detection of target analytes. Furthermore, the development of different DNA amplification techniques has enabled the enhancement of the signal to improve the sensitivity of assays.72,727 Enzymatic signal amplification approaches suffer from several limitations due to the influence of parameters such as temperature and pH. Therefore, signal amplification approaches without using an enzymatic process are highly desirable to overcome such limitations. HCR amplification is one of the methods that have been widely employed to enhance the signal. Ge et al.724 demonstrated a GO-based fluorescent-based biosensor for biothiol detection with hairpin DNA-selective fluorescence quenching and signal amplification via thymine–Hg(ii)–thymine (T–Hg2+–T) and HCR coordination control. The sensing mechanism is shown in Fig. 34D. The target biothiol molecules initiate the formation of long duplex chains utilizing T–Hg2+–T coordination chemistry, giving rise to an amplified fluorescence emission. The fluorescence quenching ability of GO and HCR reduces the background signal and enhances the detection sensitivity. The biosensor showed an LOD of 0.08 nM for biothiols. Xi et al.728 also developed a fluorescence biosensor by combining fluorescence quenching ability of GO with HCR amplification. The biosensor showed a dynamic range of 0.0001 to 100 U mL−1 and an LOD of 0.00006 U mL−1.
4.3. Fluorescent detection of pathogens and food toxins
The strong fluorescence quenching properties of graphene-based nanomaterials have attracted tremendous attention for developing aptamer-based fluorescence quenching sensing probes for detecting pathogens and food toxins.729 Shi et al.678 developed a FRET biosensor using GQDs and AuNPs for Staphylococcus aureus, achieving a fluorescence quenching efficiency of approximately 87% in a 100 nM target oligo and an LOD of 1 nM. The biosensor was designed by immobilizing capture probes on GQDs and conjugating the reporter probes to AuNPs. The sandwich-type structure was formed by cohybridizing the target oligos with the capture probes to trigger the FRET effect. Lu et al.684 developed an aptamer-based fluorescence recovery assay for detecting AFB1 mycotoxin, a secondary fungal metabolite of A. flavus, using a FRET-based quenching system composed of CdTe QDs and GO. In this system, a thiolated aptamer specific for AFB1 was linked to the surface of CdTe QDs; thus, the fluorescence of the aptamer-modified CdTe QDs was quenched by the GO. The fluorescence is restored after adding AFB1 which also depends on the quantity of AFB1. The developed CdTe QDs/GO showed a wide linear range of 3.2 nM to 320 μM and an LOD of 1.0 nM. Moreover, sensor showed a linear range of 1.6 nM to 160 μM and an LOD of 1.4 nM in peanut oil solution.
Wu et al.682 developed an aptasensor for detecting mycotoxins based on multicolor UCNPs as donors and GO as an acceptor. Two mycotoxins, ochratoxin A (OTA) and fumonisin B1 (FB1) were used in this study. The UCNPs BaY0.78F5:Yb0.2,Er0.02 and BaY0.78F5:Yb0.7,Tm0.02 were prepared and functionalized via OTA-aptamer and FB1-aptamer immobilization (Fig. 35A). Both tetraethyl orthosilicate (TEOS) and APTES were used to prepare amino-modified BaYF5:Yb Er/Tm UCNPs, which were then be conjugated with avidin employing GA method. The avidin-conjugated BaYF5:Yb Er/Tm UCNPs were linked with biotin-functionalized OTA- and FB1-aptamers, respectively. Strong upconversion fluorescence was displayed by both the OTA aptamer-modified BaYF5:YbEr UCNPs and the FB1 aptamer-modified BaYF5:Yb Tm UCNPs at a 980 nm excitation wavelength. GO completely quenches the upconversion fluorescence of UCNPs owing to the strong overlap between the GO absorption and multicolor UCNP fluorescence spectra. Due to changes in aptamer formation when they bind OTA and FB1, aptamer-modified UCNPs form further away from the GO surface. This aptasensor exhibited a linear range of 0.05–100 ng mL−1 and 0.1–500 ng mL−1 for detection of OTA and FB1 with LODs of 0.02 and 0.1 ng mL−1, respectively. Fig. 35B shows the selectivity for OTA and FB1 against other interfering mycotoxins, including aflatoxins AFB1, AFB2, AFG1, and AFG2, and AFG2, fumonisin B2 (FB2) and zearalenone (ZEN). A dramatic enhancement in fluorescent intensity was observed for OTA and FB1 compared with other mycotoxins at a concentration of 10 ng mL−1. The fluorescent intensity showed no change with other mycotoxins because UCNPs/GO form specific interactions with OTA and FB1 aptamers. Yan et al.723 developed a sensitive and highly selective DNA aptasensor to detect S. Paratyphi A by using GO as an efficient fluorescence quencher and two short carboxyfluorescein-modified sequences in a DNase I-mediated target recycling amplification (TRA) approach. When the target is absent, the aptasensor selectively bound with GO, causing fluorescence quenching of FAM. In the presence of the S. Paratyphi A target, the aptasensor disconnects from the GO surface due to aptasensor-to-target binding, resulting into a strong fluorescence that could be further amplified and detected by a DNase I-mediated TRA strategy. The resulting aptasensor displayed high sensitivity and selectivity with an LOD of 1 × 102 cells per mL. Li et al.686 reported a fluorescence quenching based sensing probe for aflatoxin B1 (AFB1) combined with an HCR amplification approach using a GO/AuNC nanocomposite. The HCR strategy displayed 94% quenching efficiency for the fluorescent probes and considerable enhancement of the LOD, reaching 0.03 pg mL−1 for AFB1 detection.
4.4. Fluorescent detection of toxic heavy metal ions
Graphene-based nanocomposites have been widely used as fluorescent probes to detect metal ions such as Ag+, Pb2+, Hg2+, Cu2+, and Fe3+ with high levels of sensitivity and selectivity.21 Metal ions can bind selectively to specific DNA nitrogenous bases. Therefore, DNAzyme-based sensors with different signal transduction mechanisms have been developed using graphene.72 However, the diverse chemical structures of graphene, GO and rGO lead to complexities in the selective detection of multiple metal ions. Wen et al.730 demonstrated a fluorescent nanoprobe using GO and an Ag-specific oligonucleotide for the detection of Ag(i) ions. The sensor exhibited an LOD of 20 nM, and the Stern–Volmer constant (Ksv) of Ag+ to silver-specific cytosine-rich oligonucleotide (DNA oligonucleotide SSO = 5′-FAM-CTCTCTTCTCTTCATTTTTCAACA CAACACAC-3′) was calculated to be 12 μM. The fluorescence response satisfies the sensitivity requirement (4.6 10−7 M) of the US EPA for drinking water. Wang et al.731 reported the self-assembly of fluorescent chemodosimeter (FC) molecules onto a GO surface for the detection of fluoride ions (F−). The fluorescent sensing of F− ions using GO/FC was approximately 5-fold larger than that without GO, the response time was shortened from 4 h to 30 min, and the sensitivity was 2-fold greater than that without GO.
GQDs have been investigated as a new class of fluorescent sensors for detecting a wide range of metal ions due to their improved optical properties and fluorescence quenching capability compared to GR and GO.102 In addition, the small size, improved photostability, good solubility, chemical inertness and high biocompatibility of the GQDs are advantageous for the fabrication of fluorescent biosensors with high sensitivity and selectivity in the presence of interfering analytes.102 Surface-functionalized GQDs have been applied for the fluorescent detection of metal ions. Zhu et al.700 demonstrated a fluorescent approach using GQDs for the detection of Fe3+ ions (Fig. 36). The strong coordination between the hydroxyl (–OH) groups on the GQDs and Fe3+ ions forms aggregates of iron hydroxide, which gives rise to fluorescence quenching. The GQD sensor displayed a very low solubility product constant (Ksp) 2.8 × 10−39 for ferric hydroxide [Fe(OH)3] compared with Cu(OH)2 and Ni(OH)2, leading to superior sensitivity and an LOD as low as 0.45 μM. The GQDs sensor showed high selectivity toward Fe3+ ions over 10 other interfering metal ions including Ni2+, Co2+, Cu2+, Pb2+, Ca2+, Al3+, K+, Mg2+, Na+, and Zn2+ at the same concentrations of 5 μM for all metal ions. Ananthanarayanan et al.732 demonstrated an IL (1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) in acetonitrile)-functionalized GQD derived from CVD-grown 3D graphene for the sensitive detection of Fe3+ ions. The BMIM+ functionalization of GQDs due to the high binding affinity of ferric ions with the imidazole ring of BMIM+ enabled enhanced fluorescence quenching for a wide range of Fe3+ ions and achieved an LOD of 7.2 μM. Guo et al.733 reported a fluorescent biosensor based on N-(rhodamine B) lactam-ethylenediamine-functionalized GQDs (RBD-GQDs) for the sensitive detection of Fe3+ in 0–1 μM concentration range with an LOD of 0.02 μM in pancreatic cancer stem cells. The Fe3+ binding with RBD-GQDs, turns on the biosensor in cancer stem cells after forming RBD-GQDs-Fe3+ complex of orange-red fluorescence. RBD-GQDs showed high selectivity toward Fe3+ ions in the presence other interfering cations including Na+, K+, NH4+, Ca2+, Cu2+, Cd2+, Co2+, Hg2+, Mg2+, Mn2+, Pb2+, Ni2+, Zn2+, and Al3+. RBD-GQDs-Fe3+ also showed high photostability in living cells as the fluorescence intensity did not decrease after 12 h continuous excitation. Chowdhury and Doong697 demonstrated dopamine-functionalized GQDs with bright blue fluorescence for the detection of low levels of Fe3+ ions. The complexation and oxidation of DA were associated with detection of Fe3+ with a linear range of 20 nM to 2 μM and an LOD of 7.6 nM. Moreover, the resulting DA-GQD fluorescent biosensor was highly selective toward Fe3+ ions in the presence of other interfering metal ions including Al3+, Au3+, Fe2+, Hg2+, Ca2+, Cd2+, Cu2+, Co2+, Cr3+, Ni2+, Pb2+, Mg2+, and Mn2+, and Zn2+; however, small quenching was observed for the competitive Fe2+ and Cu2+ ions which may be associated with the adsorption of these metal ions onto the surface of GQDs. The DA-GQDs sensor shows higher sensitivity with a lower LOD compared with RBD-GQDs sensor for detecting Fe3+ ions.
The heteroatom doping of GQDs drastically enhances their electrical properties, leading to unusual fluorescent properties and surface reactivity.88 Li et al.734 prepared sulfur-doped GQDs with stable blue-green fluorescence for the enhanced detection of Fe3+. S-doping effectively alters the local electronic density of the GQDs and thus the coordination interaction between Fe3+ and phenolic hydroxyl groups on the surface. This coordination interaction induces efficient fluorescence quenching, enabling improved sensitivity in a linear range of 0–0.7 mM and an LOD of 4.2 nM. This biosensor was also useful for the direct analysis of Fe3+ in human serum samples, indicating its potential for future clinical diagnosis. Peng et al.705 developed a facile approach for the rapid detection of Hg2+ using N-GQDs, which increase the complexation rate between 5,10,15,20-tetrakis(1-methyl-4-pyridinio)porphyrin tetra(p-toluenesulfonate) (TMPyP) and manganese ions (Mn2+). In this strategy, the substitution reaction between the deformed TMPyP nucleus and the Hg2+ ions facilitates the effective detection of small divalent metal ions by utilizing N-GQDs. At the same time, the effective formation of metalloporphyrin coupled with the fluorescence quenching of porphyrins improves the fluorescence of N-GQDs due to the inner filter effect between porphyrins and N-GQDs from the back. This sensor detected Hg2+ with an LOD of 0.2 nM. Fig. 37 shows the fluorescence spectra of (TMPyP) after the addition of N-GQDs, MnII, and different concentrations of HgII ranging from 0 to 200 nM, a plot of the fluorescence ratio (I490/I658) vs. HgII concentrations, the absorption spectra and the selectivity of HgII among different interfering analytes including BaII, CdII, CoII, CuII, FeII, MgII, NiII, PbII, ZnII, HCO3−, NO3−, Cl−, and SO42−, where the system of N-GQDs and MnII is highly selective in detecting HgII over a very wide range of concentrations.
4.4.1. Amplified detection of heavy metal ions
Numerous strategies have been pursued to enhance the fluorescent signal for the amplified detection of various metal ions, as shown in Table 10. Effective DNAzyme-based sensors have been designed to detect a broad range of metal ions using various signal transduction mechanisms.21 Wen et al.689 developed a GO-based DNAzyme for selectively detecting Pb2+. Their biosensor was fabricated by employing a Pb2+-dependent DNAzyme consisting of 2 strands, an enzyme strand, and a Cy3 fluorescent dye-tagged ribonucleotide-containing substrate strand; the ribonucleotide was the site of cleavage. Cy3 fluorescent dye namely 1,1′-bis(3-hydroxypropyl)-3,3,3′,3′-tetramethylindocarbocyanine, consists of a conjugated chain of three methine ( CH–) groups. This modification of the DNAzyme enabled an extension of 5 bases at the 3′ end of the substrate and 5 complementary bases at the 5′ end of the enzyme strand. The rigid DNAzyme double strand did not bind GO well, and there was strong emission from Cy3 dye, without Pb2+. When Pb2+ is introduced, the substrate strand is irreversibly cleaved at this site, leading to the duplex DNAzyme being disassembled into the 3′- and 5′- fragments of the substrate strand and the enzyme strand. The GO surface adsorbed the short Cy3 dye-containing segment of DNA, resulting in significant fluorescence quenching. The resulting fluorescent sensor exhibited an LOD of 0.5 nM for the detection of Pb2+, which is significantly lower than the limit set by the US EPA for drinking water (72 nM). Zhao et al.726 reported a GO-based DNAzyme containing different numbers of bases for the amplified fluorescence “turn-on” detection of Pb2+. The hybrid DNAzyme–substrate was used for molecular recognition and as signal reporter. GO acted as a highly effective quencher. The resulting biosensor exhibited an amplified fluorescence signal with detection of Pb2+ with an LOD of 300 pM. The sensor also was effectively employed in Pb2+ analysis in samples of river water. The DNAzyme-GO-based fluorescence sensor also showed high selectivity toward Pb2+ ions among nine other interfering metal ions, including Hg2+, Zn2+, Mn2+, Co2+, Cd2+, Mn2+, Ca2+, Ni2+, Cu2+, and Fe3+, and the fluorescence response toward Pb2+ was found to be remarkably high. Liu et al.688 demonstrated a “turn-on” fluorescent biosensor based on a graphene-DNAzyme catalytic beacon for the sensitive detection of Cu2+. The graphene acts as substrate and quencher for the Cu2+-dependent DNAzyme, promoting graphene-quenched DNAzyme complex formation that through a process of self-assembly. The quenched fluorescence was recovered in 15 min. The sensors exhibited improved sensitivity with an LOD of 0.365 nM. Liu et al.687 also reported label-free fluorescent detection of Cu2+, using an externally introduced fluorophore and cleavage of DNA internally in a graphene/DNAzyme complex. This sensor showed an LOD as low as 2 nM. Fang et al.699 showed a macroporous GF-based DNAzyme for the detection of Pb2+ and Cu2+. This biosensor achieved LOD of 50 pM for Pb2+ and 0.6 nM for Cu2+, and the sensor also showed detection of these ions in river water samples with high recovery.
Enzymeless signal amplification strategies have also been widely applied for the sensitive and selective detection of metal ions. Huang et al.602 developed a GO-based fluorescent biosensor using HCR for detecting Hg2+ in aqueous solution using GO to adsorb ssDNA. The biosensor showed an LOD of 0.3 nM for Hg2+ detection. They constructed a thymine-rich ssDNA initiator and two fluorescently labeled hairpin probes (Fig. 38). The GO surface adsorbed the hairpins in the absence of Hg2+; one of the hairpin probes quenched the fluorescence. However, the presence of Hg2+ initiates the HCR process between the two hairpin probes using the coordination chemistry of the thymine–Hg2+–thymine coordination compound. The GO surface cannot adsorb the final HCR double-stranded DNA (dsDNA); therefore, the fluorescence of the system is released by the GO and recovered.
4.5. Fluorescence detection of pesticides
Nanomaterials offer unique possibilities in optical biosensing platforms for the detection of food and chemical contaminants.603 In particular, GQDs have been studied for the detection of pesticides through FRET mechanisms because of their unique fluorescence quenching properties. GQDs have also been used as fluorophores for the fabrication of highly efficient fluorescence-based biosensors for pesticide detection.103 Zor et al.735 developed a GQD-based multifunctional nanocomposite as a photoluminescent sensor probe in which molecularly imprinted polypyrrole captures the chemical species, magnetic silica beads support the separation mechanism and GQDs optically recognize the target chemical species. This sensor showed an LOD of 12.78 ppb in water and 42.56 ppb in seawater for the tributyltin (TBT) pesticide. Lin et al.706 reported an N-GQD-based aptamer biosensor for the detecting pesticide omethoate with an LOD of 0.041 nM. In this study, the GQDs were first doped with nitrogen to enhance the fluorescence quantum efficiency to 30%, followed by coupling with an omethoate aptasensor. The fluorescence polarization technique based on the polarization signal of GQDs lowered the LOD from 0.041 nM to 0.029 fM. Gao et al.736 developed a pesticide biosensor array for the detection of multiple pesticides using N-(aminobutyl)-N-(ethylisoluminol) (ABEI)-functionalized GQDs. The biosensor array can be used to effectively differentiate different pesticides, such as flubendiamide, thiamethoxam, dimethoate, chlorpyrifos and dipterex, and the ABEI-GQD-based sensor detected pesticides with LOD of 10 ng mL−1. Yan et al.737 used a GQD–manganese dioxide nanosheet-based fluorescent sensor for detecting glutathione in living cells. The sensor showed a linear range of 0.5–10 μmol L−1 and an LOD of 150 nmol L−1 for glutathione. The MnO2 nanosheets act as a quencher for the GQDs through FRET and recognize glutathione molecules. The fluorescence sensor also showed high selectivity toward glutathione among common interfering analytes, including Na+, K+, Ca2+, Mg2+, Mn2+, aspartic acid, glycine, tyrosine, glucose, fructose, BSA, acetylcholinesterase (AChE), tyrosinase, glucose oxidase (GOx), and trypsin. The fluorescence intensity remained almost constant, while the fluorescence intensity of the GQD–MnO2–GSH sensor was found to increase only after adding glutathione (Fig. 39). Liu et al.707 used a GQD–MnO2 nanosheet MIP to fabricate a fluorescent sensor for thiacloprid detection. The sensor showed a linear range of 0.1 to 10 mg L−1 and a low LOD of 0.03 mg L−1 in the thiacloprid pesticide detection. Nemati et al.738 detected ethion using N- and S- codoped GQD-based fluorescent biosensors. The N/S-GQD-based sensors showed a linear concentration range of 19.2–961.2 μg L−1 and an LOD of 8 μg L−1 for detecting ethion in food samples in the presence of mercury (Hg2+) ions.
5. Selectivity of graphene-based biosensors
The performance of a biosensor is evaluated based on its high sensitivity and selectivity toward a target biochemical analyte, achieved by excluding other interfering chemical species. Graphene-based sensor arrays have been developed for the simultaneous detection, differentiation and categorization of various analytes within a mixture by using linear discriminant analysis (LDA) and principal component analysis (PCA) to identify patterns. The high selectivity of graphene-based sensor arrays was reported for the detection of volatile organic compounds (VOCs),739 gases,740 organophosphate pesticides,741 bisphenol A,742,743 cancer biomarkers,744 proteins,745,746 dopamine (DA),457,747,748 and the amino acid tyrosine.749 A few examples of sensitivity, high selectivity and strategies for excluding interfering analytes for graphene-based biosensors are provided here.
Ganganboina et al.750 reported a fluorescence turn-off/on biosensor base on nitrogen-doped GQD (N-GQD)-decorated V2O5 nanosheets for cysteine detection in human serum. N-GQDs of 2–8 nm in diameter were deposited on few-layered V2O5 nanosheets to develop a fluorescence turn-off/on probe. The V2O5 nanosheets function as both cysteine detectors and fluorescence quenchers in the biosensor. The quenching of the fluorescence intensity of N-GQDs occurs after deposition onto the V2O5 nanosheets. Fig. 40 shows the fluorescence spectra of the N-GQD@V2O5 nanocomposite-based sensor for detecting cysteine in the 0 to 125 μM concentration range and the selectivity of cysteine in the presence of 22 common interfering electrolytes and biological analytes, including metal ions, inorganic salts, amino acids, sugar, reducing agents, proteins, and glucose oxidase. The addition of 60 μg mL−1 of V2O5 nanosheets was found to turn off the fluorescence intensity of N-GQDs, whereas the fluorescence subsequently turned on 4 min after the addition of cysteine in the 0–125 μM concentration range. The inclusion of cysteine initiates the reduction of V2O5 to V4+ and the discharging of N-GQDs, which consequently causes the fluorescence to turn off/on for cysteine sensing. The N-GQDs@V2O5 sensing probe showed a two-stage linear response for cysteine detection, a sharp rise in the fluorescence at the low concentration range of 0.1–15 μM and thereafter a slight increase in the 15–125 μM range at 6.5 pH, and an LOD of 50 nM. A correlation coefficient of 0.994 was obtained in the 0.1–15 μM concentration range. The surface-mediated reaction between cysteine and N-GQDs@V2O5 composites is fast in the low cysteine concentration range of 0.1–15 μM range due to the abundance of reactive sites on the N-GQD@V2O5 nanosheets, whereas the availability of reactive sites on V2O5 nanosheets is significantly reduced over time in the high cysteine concentration range of 15–125 μM. The N-GQD@V2O5 nanocomposite-based sensor showed recoveries of 95%–108% for cysteine detection in human serum. The N-GQD@V2O5 nanocomposites showed high sensitivity and selectivity for detecting cysteine. The high selectivity toward cysteine was also demonstrated by the N-GQD@V2O5-based sensor in the presence of 22 common interfering analytes: Na+, K+, Mg2+, Ca2+, Mn2+, Cu2+, Fe3+, Zn2+, tyrosine, glutathione, methionine, aspartic acid, glucose, fructose, citric acid, AA, glutamic acid, UA, BSA, tyrosinase, acetylcholinesterase, and GOx. Protein concentrations were 100 μM and other analyte concentrations were 500 μM (the spiked concentration of cysteine was 50 μM). The N-GQD@V2O5 sensor fluorescence recovery was <10% for most of the interfering analytes except for glutathione and aspartic acid, which showed 16%–23% fluorescence intensity; however, all 22 interfering species showed significantly lower fluorescence intensity than cysteine. The smaller thiol group on the cysteine molecule may interact more rapidly with the V2O5 nanosheet surface, resulting in enhanced fluorescence recovery compared with the larger glutathione molecule.
The highly sensitive and selective detection of 4-nitrophenol using AuNPs@sulfur-doped GQD sensors was reported.751 The AuNPs@S-GQD sensing probe showed a detection range of 0.01–50 μM for 4-nitrophenol with an LOD of 8.4 nM in contaminated food wastewater and a dynamic range of 0.005–50 μM with an LOD of 3.5 nM in deionized water. The AuNPs@S-GQD sensor also showed high selectivity for 4-nitrophenol in the presence of 7 interfering analytes, including 50 μM toluene, phenol, 2-nitrotoluene, 4-nitrotoluene, 2-nitrophenol, 2,4,6-trinitrophenol, and 1-chloro-4-nitrobenzene, under identical conditions. The recovery of 4-nitrophenol by the AuNPs@S-GQD nanocomposites in the 100 nM to 20 μM concentration range was found to be in a similar range, from 97 ± 2% to 110 ± 3%, to that in the lake water. This study demonstrated the high sensitivity and selectivity of AuNPs@S-GQD-based optical sensor for 4-nitrophenol in complex mixed aqueous solutions.
Biosensor arrays fabricated using nanographene oxide (nGO) have been studied for the selective detection biomolecular species with pattern recognition techniques.752,753 Oligonucleotides or peptides that specifically bind to a target molecule have been used for such target identification. Chou et al.753 demonstrated a size-dependent effect in the use of GO flakes for the selective detection of different proteins by fluorescence response patterns. A schematic representation of the nGO-based biosensor array and chemical structures of the five fluorophores used in this study are shown in Fig. 41. GO acts as a quencher for fluorophores, and fluorescence is observed due to the interactions between GO-analyte proteins after the displacement of quenched fluorophores. To demonstrate the size-dependent effect, LDA was used to analyze the displacement of fluorophores and to compare the GO–proteins formed with conventional GO and nGO flakes (20 nm diameter). A higher fluorescence response was measured for nGO than for conventional GO flakes due to increased protein interactions, showing the effect of flake size. Five different fluorophores, including acridine orange, pyronin Y (PY), rhodamine B, rhodamine 6G (R6G), and histone-tagged emerald green fluorescent protein (His-eGFP), were used in the development of arrays. Three fluorophores, pyronine Y, rhodamine 6G, and His-eGFP, were found to be significantly effective in generating responses among these five fluorophores. Eight analyte proteins of different sizes were included in the test, including BSA, β-galactosidase (β-Gal), hemoglobin (Hem), Histone (His), lipase (Lip), lysozyme (Lys), myoglobin, and ribonuclease A (Rib-A). The training matrix data of different proteins were obtained at 10 and 100 nM protein concentrations with the conventional GO and nGO arrays. The correlation of the fluorescence response from the conventional GO and nGO arrays at 10 and 100 nM concentrations of analyte proteins and their LDA scores were scrutinized, and a 10-fold increase was observed for the 10 nM concentration compared with analogous sensor arrays. A success rate of >95% was obtained for the identification of 48 unknown analytes at both 10 and 100 nM.
Biosensor arrays based on conventional GO and nGO were studied for the discrimination of analyte proteins with five fluorophores. With five sensors, each with eight proteins, and five replicates of each analyte protein present for each sensor, there were 200 data points for each biosensor array. The fluorescent signal intensity showed higher fluorophore displacement rates for the nGO-based array than for the conventional GO arrays because of the higher protein affinity for nGO surfaces resulting from the presence of edges. An LDA/jackknife accuracy of 100% was observed using only three fluorophore sensors (eGFP, R6G, and PY) in the nGO array at 100 nM. The canonical factors of 48.7, 32.6, and 18.7% were produced from training matrix data with 3 sensors × 8 proteins × 5 replicates in the LDA method. The jackknife analysis demonstrated 100% separation using acridine orange-, rhodamine B-, eGFP-, R6G-, and PY-based fluorophore sensors at 100 nM and 98% separation with eGFP, R6G, and PY fluorophores. The canonical charts were found to be overlapped and significantly compressed (69.7%, 21.4%, and 8.9%), showing an inability to identify unknown analytes. The GO and nGO-based arrays were also compared at 10 nM protein concentrations under similar experimental conditions (Fig. 42). The canonical score plot obtained by the LDA method showed 95% accuracy in the jackknife classification using the nGO sensor array at a 10 nM protein concentration, while the corresponding canonical score plot exhibited an unclear classification for the conventional GO-based sensor array. The nGO-based array showed high reproducibility of 24 out of 24 (protein concentration of 100 nM) and 22 out of 24 (10 nM) compared with 17 out of 24 (100 nM) and no ability to distinguish proteins (10 nM) for conventional GO arrays. Analyte protein discrimination was clearly observed at a 10 nM concentration for R6G, PY and eGFP fluorophores. The selectivity for different proteins depends upon the size scaling of GO flakes, where properties such as electrical conductivity, elasticity and viscosity may play important roles. Similar nGO-based biosensor arrays were previously reported for the selective detection of ensemble aptamer proteins by Pei et al.752
Luminescent nanomaterials possessing aggregation-induced emission (AIE) characteristics have attracted attention as fluorescent sensors because of their high sensitivity and selectivity.665,754–759 Graphene-based fluorescent sensor arrays have been studied for biomolecule identification. Shen et al.760 used AIE and GO complexes to develop a fluorescent sensor array for detecting microbial lysates through their competitive biomolecular interactions (Fig. 43). Using AIE/GO complex-based sensor arrays, six microbial bioanalytes including two fungi (Candida albicans and Saccharomyces cerevisiae) and four bacteria including two Gram-positive bacteria (Staphylococcus aureus and Bacillus subtilis) and two Gram-negative bacteria (Pseudomonas aeruginosa and E. coli), were discriminated and identified. The reproducibility of AIE/GO complex sensor array was confirmed through PCA where each test was conducted five times and six microbial lysates were discriminated with 100% (F1 = 61.3% + F2 = 29.9%) efficiency with F1 and F2 as the main contributing rates in the PCA method. The two fungi are located in the upper-left side whereas the two Gram-negative bacteria and two Gram-positive bacteria are situated in the upper-right side and bottom areas in the PCA plot. The high efficiency of identification and discrimination with AIE/GO sensor arrays resulted from the different molecular components of each microbial lysate and their competitive biomolecular interactions. Xu et al.761 developed GO-based AIE biosensors with tetraphenylethene dye that exhibited high sensitivity and selectivity for detecting BSA protein. The fluorescence intensity recorded at an excitation wavelength of 350 nm increased dramatically for BSA molecules compared with the response to interfering lysozyme, papain, pepsin and trypsin proteins at 200 μg mL−1. Similar PL intensity enhancement in the fluorescence spectra was observed for BSA compared to other proteins under the same experimental conditions. Therefore, GO-based AIE biosensors are highly selective for BSA.
Huang et al.762 used PtNPs-decorated graphene, cyclodextrin prepolymer (CDP) and MWCNT nanocomposite-based biosensors to simultaneously detect hydroquinone (HQ) and catechol (CC). The PtNP-graphene/CDP-MWCNT/GCE electrochemical sensor showed linear ranges of 0.05 to 27.2 μM and 0.1 to 27.2 μM and LOD values of 0.015 μM and 0.03 μM for the simultaneous detection of HQ and CC, respectively. The HQ and CC measured in local river water showed recoveries ranging from 98.0% to 102.0% for HQ and from 99.3% to 101.5% for CC. The selectivity for HQ and CC was studied against 21 different interfering inorganic ions and organic analytes. The addition of 1000-fold concentrations of Al3+, Cu2+, Zn2+, Mg2+, Na+, K+, NH4+, SO42−, Cl−, and NO3−, 100-fold of Fe3+, Ni2+, Ca2+, SO32−, S2−, and Br−, 10-fold of resorcinol (RC), phenol, nitrophenol (NP), glucose and UA showed no interference with the detection of 50 μM HQ and CC (Fig. 44). Therefore, the PtNP-graphene/CDP-MWCNT/GCE electrochemical biosensor is highly selective and sensitive to the presence of HQ and CC.
Hybrids or nanocomposites of graphene with other semiconducting nanoparticles and polymers have been used to develop highly selective sensors for differentiating chemical species.48,206,763,764 Toxic metal ions, including Hg2+ions,693,696,765 Mn2+,766 Pb2+,689,692 Cu2+,694,767 Fe3+,768 Fe3+, Cd2+ and Pb2+,769 Ce3+,770 Pb2+, Zn2+ and Cd2+,771 Tl+, Pb2+ and Hg2+,772 and Ag+,702,730,773 and the mycotoxin OTA,683 have been selectively detected using graphene-based sensors.
Mao et al.,766 developed a fluorescent sensor based on 1,2-bis-(2-pyren-1-ylmethylamino-ethoxy) ethane (NPEY) and graphene nanosheets (GNs) for the detection of Mn2+ both in vitro and in living cells utilizing π–π interactions. Fig. 45 shows the fluorescence intensity of NPEY/GNs hybrid system to different metal ions, schematic illustration of fluorescence mechanism for detecting Mn2+ with NPEY/GNs hybrid, and confocal fluorescence microscopy images of HeLa cells with NPEY, NPEY/GNs hybrid with and without Mn2+ ions. HRTEM image of NPEY/GNs hybrid confirmed the NPEY decorated GNs. The GNs quenched fluorescence emission occurring between NPEY molecules and GNs due to the π–π stacking interactions facilitated by the photoinduced electron transfer (PET) process. NPEY/GNs hybrid-based sensor showed high sensitivity and selectivity toward Mn2+ ions against other interfering heavy metal ions including Ag+, Hg2+, Zn2+, Cr2+, Ca2+, Ni2+, Cd2+, and Pb2+. The Mn2+ ions lead to a significant increase in the fluorescence intensity of NPEY/GNs hybrid. AFM showed no interaction between Mn2+ ions and GNs demonstrating the non-sensitivity of GNs. The ethylene glycol and imino groups of NPEY assist in binding with Mn2+ ions. The NPEY/GNs hybrid-based sensor also showed the imaging and detection of Mn2+ ions in living cells.
Niu et al.704 developed a “turn-on” fluorescence sensor using GQD and AuNP conjugates for Pb2+ detection. The GQD/AuNP-based fluorescence sensor showed a Pb2+ detection range of 50 nM to 4 μM with an LOD of 16.7 nM and very high sensitivity and selectivity for Pb2+ ions in the presence of ten other interfering metal ions. Fig. 46 shows the fluorescence intensity response measured for 200 nM concentrations of Mn2+, Fe3+, K+, Hg2+, Cu2+ Mg2+, Ca2+, Zn2+, Cd2+, and Ag+ ions and 50 nM Pb2+ ions. The fluorescence increased sharply with the addition of 50 nM Pb2+, whereas no significant change in fluorescence was observed after the addition of 200 nM concentrations of ten other interfering metal ions. The Pb2+ ions showed almost 3-fold higher restoration efficiency than the other interfering metal ions, clearly differentiating Pb2+ from all metal ions. Other metal ions were not able to cleave the catalytic DNA strand and did not separate the GQDs and AuNPs; therefore, no quenching recovery was observed except for Pb2+ ions. The high sensitivity and selectivity of the fluorescent sensor toward Pb2+ ions occurred due to the FRET between GQDs and AuNPs. The strong fluorescence quenching and fluorescence recovery resulted from the combination of GQDs and AuNPs and their deaggregation, which was induced by the catalytic DNA strand and Pb2+ ions.
Jiang et al.774 fabricated electrochemical immunosensors using GO/AgNPs composites for the detection of E. coli SEM images of mica sheets coated with AuNPs/gold, BSA/antibody(Ab)/AuNPs/gold, E. coli/BSA/Ab/AuNPs/gold, and P-GO–AgNPs–Ab/E. coli/BSA/Ab/AuNPs/gold were compared, and the selectivity of the detection of different bacteria was measured by analyzing current signals. Current responses of 0.946 μA for B. subtilis (1.8 × 104 CFU mL−1), 1.124 μA for Enterobacter aerogenes, (2.0 × 104 CFU m L−1), 1.505 μA for Enterobacter dissolvens (2.5 × 104 CFU mL−1), and (d) 17.3000 μA for (E. coli (1.0 × 104 CFU mL−1) were observed. Zhang et al.775 developed a fluorescent aptasensor assay using GO for detecting mucin 1 protein (MUC1) by employing deoxyribonuclease I (DNase I)-mediated target cyclic amplification. Fig. 47 shows the schematics of the GO-based fluorescent aptasensor assay, fluorescence intensity of the GO-based aptasensor for detection of MUC1 protein in the presence of different interfering proteins including epithelial cell adhesion molecule (EpCAM), BSA, prostate-specific antigen (PSA), vascular endothelial growth factor (VEGF and the biological samples of human urine, saliva and serum. The GO-probe/MUC1 complex formation plays an important role for the fluorescence detection. The GO strongly adsorbs deoxyribonuclease I (DNase I) in the absence of MUC1 protein so no fluorescence signal is observed whereas a fluorescence signal is turn-on when the GO-probe/MUC1 complexes are formed in the presence of MUC1. In this process, the DNA sequences are damaged after adding DNase which releases MUC1 and FAM fluorophores. The GO-based aptasensor showed a dramatic increase in the fluorescence intensity as the concentration of MUC1 was increased from 0 to 300 ng mL−1 with a linear range from 50 pg mL−1 to 100 ng mL−1 and an LOD as low as 10 pg mL−1. The GO-based biosensor showed a significant increase in fluorescence intensity for 5 ng mL−1 concentration of MUC1 compared with 50 ng mL−1 concentration of each interfering EpCAM, BSA, PSA, and VEGF analytes. The GO biosensor demonstrated high selectivity and sensitivity toward MUC1 protein in the presence of EpCAM, BSA, PSA, VEGF proteins and MUC1 spiked biological samples of human serum, urine and saliva. The high sensitivity of the GO biosensor originated from the fluorescence signal amplification by DNase I-mediated target recycling process and the accumulation of FAM fluorophores.
The selectivity of graphene-based biosensors has been discussed throughout this article, which showed that the selectivity is governed by a number of factors, including morphological nanostructures, structural defects, interlayer spacing, and the nature and concentrations of dopants, and interfering analytes. Graphene-based biosensor arrays could accurately identify and classify a group of bioanalytes from interferents with the help of LDA and PCA pattern recognition methods. Furthermore, the nature of GBMs such as graphene, GO, and rGO, their functional reactive groups, such as –OH, –COOH, –CO, and –C–O–C, and their interactions with biomolecules are equally crucial for selectivity at the nanomolar level.
New graphene-based electrochemical and fluorescent biosensors are emerging rapidly for the detection of pathogenic E. coli O157:H7,564,776 Typhoidal Salmonella,777S. aureus,778 Johne disease,779 insulin,780 protein kinase activity,781 bisphenol A,782 AFB1,686 fenitrothion pesticide,783 circulating tumor cells (CTCs),784 breast cancer gene,785 Zika virus,786M. tuberculosis,787 glucose,788 and microRNA in living cells.789 corrosion sulfate-reducing bacteria (SRB),790 pyrophosphate,791 florfenicol in milk,792 foodborne mycotoxin,793 anticancer drug regorafenib,794 anticancer chemotherapy drug bleomycin,795 Alzheimer disease biomarker,796 tumor cells,797 HPV,798 dengue virus,799 HBV,800,801 hepatitis C virus,802 liver cancer cells,803 vascular endothelial growth factor 165 (VEGF165) for cancer diagnosis,804 human protein of cardiac troponin I (cTnI) biomarker for acute myocardial infarction,805,806 progesterone hormone,807 17β-estradiol,808 stem cell differentiation,809 adenosine 5′-triphosphate (ATP),810 acetaminophen,811 tetracyclines,812 and lectins.813
The strong quenching ability of GO and rGO compared with graphene offers exciting opportunities for the development of fluorescent biosensors with significantly improved sensitivity, selectivity, and low detection limits. The integration of graphene nanomaterials with inorganic nanoparticles and UCNPs combine the advantages of high carrier mobility and greatly enhanced quenching for the amplified detection of biomolecules. Finally, the high sensitivity and selectivity of the electrochemical and fluorescent biosensor platforms have already been used in clinical testing814 and cancer biomarkers,815–821 demonstrating the promising future of inexpensive biosensing platforms.
6. Conclusions
Significant advances have been made in developing new biosensors using graphene-based nanomaterials for the detection of a wide variety of biological analytes, including glucose, H2O2, cholesterol, NAs, cancer biomarkers, food pathogens, heavy metal ions and pesticides, with desirable levels of sensitivity, low detection limits and good stability. Importantly, the successful integration of nanoscale materials such as inorganic nanoparticles (metals, metal oxides and semiconductors), organic polymers and hydrogels with graphene, GO and rGO creates unprecedented capabilities for detecting a very wide variety of bioanalytes, yielding biosensors with superior performance. Furthermore, the controlled fabrication of materials into different 2D and 3D nanostructures further helps to improve the sensing capabilities. The design of nano- or microscale devices such as microfluidic chips that incorporate multiple graphene-based nanocomposite materials is particularly promising for the detection of multiple biomarkers in a single chip. These advances in biosensor research provide new and promising platforms for the sensitive detection of various biomarkers, which can provide potential solutions not only in the biomedical field but also in other applications such as the food, water, agriculture industries and environmental monitoring.
7. Outlook and future perspectives
This review summarized recent advances in designing 2D and 3D graphene, graphene/polymer and graphene/inorganic nanoparticle hybrid architectures for diverse electrochemical biosensing applications. Integrating these hybrid nanostructures with biocompatible biopolymers, conducting polymers and hydrogels further amplifies the potential of these materials with greatly improved sensitivity, selectivity and operational stability, particularly for enzymatic biosensors. Over the last decade, despite recent developments in the controlled design of graphene and graphene-based hybrid nanocomposites, the understanding of the functional properties of graphene, GO, rGO and their interactions with surface-modified polymers or inorganic nanoparticles remains a great challenge. The current synthesis approaches still lack controlled uniform deposition, assembly onto graphene surfaces and stability on the surfaces. More research efforts focusing on new and cost-effective synthetic approaches are needed to achieve precisely controlled synthesis and an in-depth understanding of the structure–property relationships of graphene nanomaterials.
The large-scale processability, biocompatibility, large surface-to-volume ratio and oxygen-terminated functional groups of graphene facilitate surface modification with diverse functionalities and the site-specific conjugation of enzymes. The preparation of graphene-based hybrid nanocomposites and fine-tuning of their structural features are promising for developing novel biosensors to solve the existing stability issues and efficiently enhance the electron transfer rate in enzymatic biosensors. For instance, 3D architectures such as highly porous graphene, graphene foam, graphene scaffolds and graphene/polymer hydrogels have been explored, which trap enzymes inside pores and cavities that are similar or matching in size to different biomolecules (e.g., enzymes, other proteins, and aptamers), which helps to retain their biocatalytic functions for an extended time, to improve their stability by avoiding leaching effects and, importantly, to enhance the electron transfer rates. Specifically, the structural features of graphene-based derivatives such as GO and rGO and the integration of inorganic nanoparticles increase the electronic conductivity and electrocatalytic activity of these hybrid nanostructures by several orders of magnitude. In the case of enzymatic biosensors, the achievement of DET with both an enhanced electron transfer rate and operational stability simultaneously still faces challenges in third-generation enzymatic biosensors. The selectivity of graphene-based biosensors has been analyzed and showed dependence on a number of factors including morphology, defects, dopants and interferents.
Graphene-based microfluidic devices have attracted increasing interest due to their many advantages over the common electrochemical approach. In particular, the devices fabricated using microporous 3D architecture that interacts with nanoparticle systems seem to be highly efficient for the detection of multiple cancer biomarkers in a single-chip device with enhanced sensitivity and detection limits reaching subpicomolar concentrations. Similarly, graphene-based porous nanostructures have had major impacts on the detection of pathogenic bacteria and heavy metal ions. Numerous studies have demonstrated the detection of biomolecules down to the picomolar concentration range by the exploitation of signal amplification strategies. Despite this progress and advances in the fabrication of electrodes and their characterization, long-term studies on the toxicity of graphene-based materials for use in clinical industry,822–827 there are still several challenges related to practical implementation, including limited lifetime, operational stability and reproducibility.
Conflicts of interest
The authors declare no competing financial interest.
Supplementary Material
References
- Malhotra B. D. Chaubey A. Biosensors for Clinical Diagnostics Industry. Sens. Actuators, B. 2003;91:117–127. doi: 10.1016/S0925-4005(03)00075-3. [DOI] [Google Scholar]
- Velasco-Garcia M. N. Mottram T. Biosensor Technology Addressing Agricultural Problems. Biosyst. Eng. 2003;84:1–12. doi: 10.1016/S1537-5110(02)00236-2. [DOI] [Google Scholar]
- Thakur M. S. Ragavan K. V. Biosensors in Food Processing. J. Food Sci. Technol. 2013;50:625–641. doi: 10.1007/s13197-012-0783-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rodriguezmozaz S. Alda M. Marco M. Barcelo D. Biosensors for Environmental Monitoring A Global Perspective. Talanta. 2005;65:291–297. doi: 10.1016/j.talanta.2004.07.006. [DOI] [PubMed] [Google Scholar]
- Su S. Chen S. Fan C. Recent Advances in Two-Dimensional Nanomaterials-Based Electrochemical Sensors for Environmental Analysis. Green Energy & Environment. 2018;3:97–106. [Google Scholar]
- Gubala V. Harris L. F. Ricco A. J. Tan M. X. Williams D. E. Point of Care Diagnostics: Status and Future. Anal. Chem. 2012;84:487–515. doi: 10.1021/ac2030199. [DOI] [PubMed] [Google Scholar]
- Nanomaterial-Based Flexible and Multifunctional Sensors, ed. E. Singh and H. S. Nalwa, American Scientific Publishers, Los Angeles, CA, 2019 [Google Scholar]
- Kelley S. O. Mirkin C. A. Walt D. R. Ismagilov R. F. Toner M. Sargent E. H. Advancing the Speed, Sensitivity and Accuracy of Biomolecular Detection Using Multi-Length-Scale Engineering. Nat. Nanotechnol. 2014;9:969–980. doi: 10.1038/nnano.2014.261. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu Q. Wu C. Cai H. Hu N. Zhou J. Wang P. Cell-Based Biosensors and Their Application in Biomedicine. Chem. Rev. 2014;114:6423–6461. doi: 10.1021/cr2003129. [DOI] [PubMed] [Google Scholar]
- Rong G. Corrie S. R. Clark H. A. In Vivo Biosensing: Progress and Perspectives. ACS Sens. 2017;2:327–338. doi: 10.1021/acssensors.6b00834. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Du Y. Dong S. Nucleic Acid Biosensors: Recent Advances and Perspectives. Anal. Chem. 2017;89:189–215. doi: 10.1021/acs.analchem.6b04190. [DOI] [PubMed] [Google Scholar]
- Huang X. Liu Y. Yung B. Xiong Y. Chen X. Nanotechnology-Enhanced No-Wash Biosensors for In vitro Diagnostics of Cancer. ACS Nano. 2017;11:5238–5292. doi: 10.1021/acsnano.7b02618. [DOI] [PubMed] [Google Scholar]
- Bereza-Malcolm L. T. Mann G. Franks A. E. Environmental Sensing of Heavy Metals Through Whole Cell Microbial Biosensors: A Synthetic Biology Approach. ACS Synth. Biol. 2014;4:535–546. doi: 10.1021/sb500286r. [DOI] [PubMed] [Google Scholar]
- Gaddes D. Reeves W. B. Tadigadapa S. Calorimetric Biosensing System for Quantification of Urinary Creatinine. ACS Sens. 2017;2:796–802. doi: 10.1021/acssensors.7b00161. [DOI] [PubMed] [Google Scholar]
- De Wael K. Daems D. Van Camp G. Nagels L. J. Use of Potentiometric Sensors To Study (Bio)molecular Interactions. Anal. Chem. 2012;84:4921–4927. doi: 10.1021/ac3005428. [DOI] [PubMed] [Google Scholar]
- Heller A. Feldman B. Electrochemical Glucose Sensors and Their Applications in Diabetes Management. Chem. Rev. 2008;108:2482–2505. doi: 10.1021/cr068069y. [DOI] [PubMed] [Google Scholar]
- Tamura T. Hamachi I. Recent Progress in Design of Protein-Based Fluorescent Biosensors and Their Cellular Applications. ACS Chem. Biol. 2014;9:2708–2717. doi: 10.1021/cb500661v. [DOI] [PubMed] [Google Scholar]
- Wang Z. Zong S. Wu L. Zhu D. Cui Y. SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications. Chem. Rev. 2017;117:7910–7963. doi: 10.1021/acs.chemrev.7b00027. [DOI] [PubMed] [Google Scholar]
- Tiwari J. N. Vij V. Kemp K. C. Kim K. S. Engineered Carbon-Nanomaterial-Based Electrochemical Sensors for Biomolecules. ACS Nano. 2016;10:46–80. doi: 10.1021/acsnano.5b05690. [DOI] [PubMed] [Google Scholar]
- Maduraiveeran G. Sasidharan M. Ganesan V. Electrochemical Sensor and Biosensor Platforms Based on Advanced Nanomaterials for Biological and Biomedical Applications. Biosens. Bioelectron. 2018;103:113–129. doi: 10.1016/j.bios.2017.12.031. [DOI] [PubMed] [Google Scholar]
- Zhang H. Zhang H. Aldalbahi A. Zuo X. Fan C. Mi X. Fluorescent Biosensors Enabled by Graphene and Graphene Oxide. Biosens. Bioelectron. 2017;89:96–106. doi: 10.1016/j.bios.2016.07.030. [DOI] [PubMed] [Google Scholar]
- Zhu C. Yang G. Li H. Du D. Lin Y. Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures. Anal. Chem. 2015;87:230–249. doi: 10.1021/ac5039863. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Handbook of Nanostructured Materials and Nanotechnology, ed. H. S. Nalwa, Academic Press, San Diego, 2000, vol. 1–5 [Google Scholar]; (b) Encyclopedia of Nanoscience and Nanotechnology, ed. H. S. Nalwa, American Scientific Publishers, Los Angeles, 2004, vol. 1–10 [Google Scholar]; (c) Handbook of Nanostructured Biomaterials and Their Applications in Nanobiotechnology, ed. H. S. Nalwa, American Scientific Publishers, Los Angeles, 2005, vol. 1–2 [Google Scholar]; (d) Georgakilas V. Perman J. A. Tucek J. Zboril R. Broad Family of Carbon Nanoallotropes: Classification, Chemistry, and Applications of Fullerenes, Carbon Dots, Nanotubes, Graphene, Nanodiamonds, and Combined Superstructures. Chem. Rev. 2015;115:4744–4822. doi: 10.1021/cr500304f. [DOI] [PubMed] [Google Scholar]
- Cobley C. M. Chen J. Cho E. C. Wang L. V. Xia Y. Gold nanostructures: a class of multifunctional materials for biomedical applications. Chem. Soc. Rev. 2011;40:44–56. doi: 10.1039/B821763G. [DOI] [PubMed] [Google Scholar]
- Sun S.-K. Wang H.-F. Yan X.-P. Engineering Persistent Luminescence Nanoparticles for Biological Applications: From Biosensing/Bioimaging to Theranostics. Acc. Chem. Res. 2018;51:1131–1143. doi: 10.1021/acs.accounts.7b00619. [DOI] [PubMed] [Google Scholar]
- Nandini S. Nalini S. Reddy M. B. M. Suresh G. S. Melo J. S. Niranjana P. Sanetuntikul J. Shanmugam S. Synthesis of One-Dimensional Gold Nanostructures and the Electrochemical Application of the Nanohybrid Containing Functionalized Graphene Oxide for Cholesterol Biosensing. Bioelectrochemistry. 2016;110:79–90. doi: 10.1016/j.bioelechem.2016.03.006. [DOI] [PubMed] [Google Scholar]
- Tan C. Cao X. Wu X.-J. He Q. Yang J. Zhang X. Chen J. Zhao W. Han S. Nam G.-H. Sindoro M. Zhang H. Recent Advances in Ultrathin Two-Dimensional Nanomaterials. Chem. Rev. 2017;117:6225–6331. doi: 10.1021/acs.chemrev.6b00558. [DOI] [PubMed] [Google Scholar]
- (a) Singh E. Kim K. S. Yeom G. Y. Nalwa H. S. Atomically thin-layered molybdenum disulfide (MoS2) for bulk-heterojunction solar cells. ACS Appl. Mater. Interfaces. 2017;9:3223–3245. doi: 10.1021/acsami.6b13582. [DOI] [PubMed] [Google Scholar]; (b) Singh E. Kim K. S. Yeom G. Y. Nalwa H. S. Two-dimensional transition metal dichalcogenide-based counter electrodes for dye-sensitized solar cells. RSC Adv. 2017;7:28234–28290. doi: 10.1039/C7RA03599C. [DOI] [Google Scholar]; (c) Singh E. Singh P. Kim K. S. Yeom G. Y. Nalwa H. S. Flexible molybdenum disulfide (MoS2) atomic layers for wearable electronics and optoelectronics. ACS Appl. Mater. Interfaces. 2019 doi: 10.1021/acsami.8b19859. [DOI] [PubMed] [Google Scholar]; (d) Singh R. Singh E. Nalwa H. S. Inkjet printed nanomaterial based flexible radio frequency identification (RFID) tag sensors for the internet of nano things. RSC Adv. 2017;7:48597–48630. doi: 10.1039/C7RA07191D. [DOI] [Google Scholar]
- Dasgupta N. P. Sun J. Liu C. Brittman S. Andrews S. C. Lim J. Gao H. Yan R. Yang P. 25th Anniversary Article: Semiconductor Nanowires - Synthesis, Characterization, and Applications. Adv. Mater. 2014;26:2137–2184. doi: 10.1002/adma.201305929. [DOI] [PubMed] [Google Scholar]
- Sapsford K. E. Algar W. R. Berti L. Gemmill K. B. Casey B. J. Oh E. Stewart M. H. Medintz I. L. Functionalizing Nanoparticles with Biological Molecules: Developing Chemistries that Facilitate Nanotechnology. Chem. Rev. 2013;113:1904–2074. doi: 10.1021/cr300143v. [DOI] [PubMed] [Google Scholar]
- Fadel T. R. Farrell D. F. Friedersdorf L. E. Griep M. H. Hoover M. D. Meador M. A. Meyyappan M. Toward the Responsible Development and Commercialization of Sensor Nanotechnologies. ACS Sens. 2016;1:207–216. doi: 10.1021/acssensors.5b00279. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Novoselov K. S. Geim A. K. Morozov S. V. Jiang D. Zhang Y. Dubonos S. V. Grigorieva I. V. Firsov A. A. Electric Field Effect in Atomically Thin Carbon Films. Science. 2004;306:666–669. doi: 10.1126/science.1102896. [DOI] [PubMed] [Google Scholar]
- Cheng C. Li S. Thomas A. Kotov N. A. Haag R. Functional Graphene Nanomaterials Based Architectures: Biointeractions, Fabrications, and Emerging Biological Applications. Chem. Rev. 2017;117:1826–1914. doi: 10.1021/acs.chemrev.6b00520. [DOI] [PubMed] [Google Scholar]
- Geim A. K. Novoselov K. S. The Rise of Graphene. Nat. Mater. 2007;6:183–191. doi: 10.1038/nmat1849. [DOI] [PubMed] [Google Scholar]
- Zhu Y. Murali S. Cai W. Li X. Suk J. W. Potts J. R. Ruoff R. S. Graphene and Graphene Oxide: Synthesis, Properties, and Applications. Adv. Mater. 2010;22:3906–3924. doi: 10.1002/adma.201001068. [DOI] [PubMed] [Google Scholar]
- Avouris P. Dimitrakopoulos C. Graphene: Synthesis and Applications. Mater. Today. 2012;15:86–97. doi: 10.1016/S1369-7021(12)70044-5. [DOI] [Google Scholar]
- Mao H. Y. Laurent S. Chen W. Akhavan O. Imani M. Ashkarran A. A. Mahmoudi M. Graphene: Promises, Facts, Opportunities, and Challenges in Nanomedicine. Chem. Rev. 2013;113:3407–3424. doi: 10.1021/cr300335p. [DOI] [PubMed] [Google Scholar]
- Meyer J. C. Geim A. K. Katsnelson M. I. Novoselov K. S. Booth T. J. Roth S. The Structure of Suspended Graphene Sheets. Nature. 2007;446:60–63. doi: 10.1038/nature05545. [DOI] [PubMed] [Google Scholar]
- Xu Y. Bai H. Lu G. Li C. Shi G. Flexible Graphene Films via the Filtration of Water-Soluble Noncovalent Functionalized Graphene Sheets. J. Am. Chem. Soc. 2008;130:5856–5857. doi: 10.1021/ja800745y. [DOI] [PubMed] [Google Scholar]
- Chen H. Müller M. B. Gilmore K. J. Wallace G. G. Li D. Mechanically Strong, Electrically Conductive, and Biocompatible Graphene Paper. Adv. Mater. 2008;20:3557–3561. doi: 10.1002/adma.200800757. [DOI] [Google Scholar]
- Li X. Wang X. Zhang L. Lee S. Dai H. Chemically Derived, Ultrasmooth Graphene Nanoribbon Semiconductors. Science. 2008;319:1229–1232. doi: 10.1126/science.1150878. [DOI] [PubMed] [Google Scholar]
- Xi Q. Chen X. Evans D. G. Yang W. Gold Nanoparticle-Embedded Porous Graphene Thin Films Fabricated via Layer-by-Layer Self-Assembly and Subsequent Thermal Annealing for Electrochemical Sensing. Langmuir. 2012;28:9885–9892. doi: 10.1021/la301440k. [DOI] [PubMed] [Google Scholar]
- Hu C. Xue J. Dong L. Jiang Y. Wang X. Qu L. Dai L. Scalable Preparation of Multifunctional Fire-Retardant Ultralight Graphene Foams. ACS Nano. 2016;10:1325–1332. doi: 10.1021/acsnano.5b06710. [DOI] [PubMed] [Google Scholar]
- Balandin A. A. Ghosh S. Bao W. Calizo I. Teweldebrhan D. Miao F. Lau C. N. Superior Thermal Conductivity of Single-Layer Graphene. Nano Lett. 2008;8:902–907. doi: 10.1021/nl0731872. [DOI] [PubMed] [Google Scholar]
- Morozov S. V. Novoselov K. S. Katsnelson M. I. Schedin F. Elias D. C. Jaszczak J. A. Geim A. K. Giant Intrinsic Carrier Mobilities in Graphene and Its Bilayer. Phys. Rev. Lett. 2008;100:11–14. doi: 10.1103/PhysRevLett.100.016602. [DOI] [PubMed] [Google Scholar]
- Nair R. R. Blake P. Grigorenko A. N. Novoselov K. S. Booth T. J. Stauber T. Peres N. M. R. Geim A. K. Fine Structure Constant Defines Visual Transparency of Graphene. Science. 2008;320:1308. doi: 10.1126/science.1156965. [DOI] [PubMed] [Google Scholar]
- Stoller M. D. Park S. Zhu Y. An J. Ruoff R. S. Graphene-Based Ultracapacitors. Nano Lett. 2008;8:3498–3502. doi: 10.1021/nl802558y. [DOI] [PubMed] [Google Scholar]
- Singh E. Nalwa H. S. Graphene-Based Bulk-Heterojunction Solar Cells: A Review. J. Nanosci. Nanotechnol. 2015;15:6237–6278. doi: 10.1166/jnn.2015.11654. [DOI] [PubMed] [Google Scholar]
- Singh E. Nalwa H. S. Graphene-Based Dye-Sensitized Solar Cells: A Review. Sci. Adv. Mater. 2015;7:1863–1912. doi: 10.1166/sam.2015.2438. [DOI] [Google Scholar]
- Lv W. Li Z. Deng Y. Yang Q.-H. Kang F. Graphene-Based Materials for Electrochemical Energy Storage Devices: Opportunities and Challenges. Energy Storage Materials. 2016;2:107–138. doi: 10.1016/j.ensm.2015.10.002. [DOI] [Google Scholar]
- Khan U. Kim T.-H. Ryu H. Seung W. Kim S.-W. Graphene Tribotronics for Electronic Skin and Touch Screen Applications. Adv. Mater. 2017;29:2–8. doi: 10.1002/adma.201603544. [DOI] [PubMed] [Google Scholar]
- Schwierz F. Graphene Transistors. Nat. Nanotechnol. 2010;5:487–496. doi: 10.1038/nnano.2010.89. [DOI] [PubMed] [Google Scholar]
- Han T.-H. Lee Y. Choi M.-R. Woo S.-H. Bae S.-H. Hong B. H. Ahn J.-H. Lee T.-W. Extremely Efficient Flexible Organic Light-Emitting Diodes with Modified Graphene Anode. Nat. Photonics. 2012;6:105–110. doi: 10.1038/nphoton.2011.318. [DOI] [Google Scholar]
- Singh E. Meyyappan M. Nalwa H. S. Flexible Graphene-Based Wearable Gas and Chemical Sensors. ACS Appl. Mater. Interfaces. 2017;9:34544–34586. doi: 10.1021/acsami.7b07063. [DOI] [PubMed] [Google Scholar]
- Iannazzo D. Pistone A. Salamò M. Galvagno S. Romeo R. Giofré S. V. Branca C. Visalli G. Di Pietro A. Graphene Quantum Dots for Cancer Targeted Drug Delivery. Int. J. Pharm. 2017;518:185–192. doi: 10.1016/j.ijpharm.2016.12.060. [DOI] [PubMed] [Google Scholar]
- Kumar V. Kim K.-H. Park J.-W. Hong J. Kumar S. Graphene and Its Nanocomposites as a Platform for Environmental Applications. Chem. Eng. J. 2017;315:210–232. doi: 10.1016/j.cej.2017.01.008. [DOI] [Google Scholar]
- Chen D. Feng H. Li J. Graphene Oxide: Preparation, Functionalization, and Electrochemical Applications. Chem. Rev. 2012;112:6027–6053. doi: 10.1021/cr300115g. [DOI] [PubMed] [Google Scholar]
- Yin P. T. Shah S. Chhowalla M. Lee K.-B. Design, Synthesis, and Characterization of Graphene–Nanoparticle Hybrid Materials for Bioapplications. Chem. Rev. 2015;115:2483–2531. doi: 10.1021/cr500537t. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhao X. Zhang P. Chen Y. Su Z. Wei G. Recent Advances in the Fabrication and Structure-Specific Applications of Graphene-Based Inorganic Hybrid Membranes. Nanoscale. 2015;7:5080–5093. doi: 10.1039/C5NR00084J. [DOI] [PubMed] [Google Scholar]
- Qiu L. Li D. Cheng H.-M. Structural Control of Graphene-Based Materials for Unprecedented Performance. ACS Nano. 2018;12:5085–5092. doi: 10.1021/acsnano.8b03792. [DOI] [PubMed] [Google Scholar]
- Nardecchia S. Carriazo D. Ferrer M. L. Gutiérrez M. C. del Monte F. Three Dimensional Macroporous Architectures And Aerogels Built of Carbon Nanotubes and/or Graphene: Synthesis and Applications. Chem. Soc. Rev. 2013;42:794–830. doi: 10.1039/C2CS35353A. [DOI] [PubMed] [Google Scholar]
- Liu F. Piao Y. Choi J. S. Seo T. S. Three-Dimensional Graphene Micropillar Based Electrochemical Sensor for Phenol Detection. Biosens. Bioelectron. 2013;50:387–392. doi: 10.1016/j.bios.2013.06.055. [DOI] [PubMed] [Google Scholar]
- Liu J. Fu S. Yuan B. Li Y. Deng Z. Toward a Universal “Adhesive Nanosheet” for the Assembly of Multiple Nanoparticles Based on a Protein-Induced Reduction/Decoration of Graphene Oxide. J. Am. Chem. Soc. 2010;132:7279–7281. doi: 10.1021/ja100938r. [DOI] [PubMed] [Google Scholar]
- Wang M. Duan X. Xu Y. Duan X. Functional Three-Dimensional Graphene/Polymer Composites. ACS Nano. 2016;10:7231–7247. doi: 10.1021/acsnano.6b03349. [DOI] [PubMed] [Google Scholar]
- Chee W. K. Lim H. N. Huang N. M. Harrison I. Nanocomposites of Graphene/Polymers: A Review. RSC Adv. 2015;5:68014–68051. doi: 10.1039/C5RA07989F. [DOI] [Google Scholar]
- Zhang R. Chen W. Recent Advances in Graphene-Based Nanomaterials for Fabricating Electrochemical Hydrogen Peroxide Sensors. Biosens. Bioelectron. 2017;89:249–268. doi: 10.1016/j.bios.2016.01.080. [DOI] [PubMed] [Google Scholar]
- Bollella P. Fusco G. Tortolini C. Sanzò G. Favero G. Gorton L. Antiochia R. Beyond Graphene: Electrochemical Sensors and Biosensors for Biomarkers Detection. Biosens. Bioelectron. 2017;89:152–166. doi: 10.1016/j.bios.2016.03.068. [DOI] [PubMed] [Google Scholar]
- Wang L. Xiong Q. Xiao F. Duan H. 2D Nanomaterials Based Electrochemical Biosensors for Cancer Diagnosis. Biosens. Bioelectron. 2017;89:136–151. doi: 10.1016/j.bios.2016.06.011. [DOI] [PubMed] [Google Scholar]
- Chikkaveeraiah B. V. Bhirde A. A. Morgan N. Y. Eden H. S. Chen X. Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers. ACS Nano. 2012;6:6546–6561. doi: 10.1021/nn3023969. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Farka Z. Juřík T. Kovář D. Trnková L. Skládal P. Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges. Chem. Rev. 2017;117:9973–10042. doi: 10.1021/acs.chemrev.7b00037. [DOI] [PubMed] [Google Scholar]
- Li M. Gou H. Al-Ogaidi I. Wu N. Nanostructured Sensors for Detection of Heavy Metals: A Review. ACS Sustainable Chem. Eng. 2013;1:713–723. doi: 10.1021/sc400019a. [DOI] [Google Scholar]
- Saidur M. R. Aziz A. R. A. Basirun W. J. Recent Advances in DNA-Based Electrochemical Biosensors for Heavy Metal Ion Detection: A Review. Biosens. Bioelectron. 2017;90:125–139. doi: 10.1016/j.bios.2016.11.039. [DOI] [PubMed] [Google Scholar]
- Reta N. Saint C. P. Michelmore A. Prieto-Simon B. Voelcker N. H. Nanostructured Electrochemical Biosensors for Label-Free Detection of Water- and Food-Borne Pathogens. ACS Appl. Mater. Interfaces. 2018;10:6055–6072. doi: 10.1021/acsami.7b13943. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Shen J. Li H. Wang L. Cao D. Feng X. Liu Y. Ma Y. Wang L. Recent Progress on Graphene-based Electrochemical Biosensors. Chem. Rec. 2016;16:273–294. doi: 10.1002/tcr.201500236. [DOI] [PubMed] [Google Scholar]
- Lawal A. T. Progress in Utilisation of Graphene for Electrochemical Biosensors. Biosens. Bioelectron. 2018;106:149–178. doi: 10.1016/j.bios.2018.01.030. [DOI] [PubMed] [Google Scholar]
- Liu Y. Dong X. Chen P. Biological and Chemical Sensors Based on Graphene Materials. Chem. Soc. Rev. 2012;41:2283–2307. doi: 10.1039/C1CS15270J. [DOI] [PubMed] [Google Scholar]
- Rasheed P. A. Sandhyarani N. Carbon Nanostructures as Immobilization Platform for DNA: A Review on Current Progress in Electrochemical DNA Sensors. Biosens. Bioelectron. 2017;97:226–237. doi: 10.1016/j.bios.2017.06.001. [DOI] [PubMed] [Google Scholar]
- Chung C. Kim Y.-K. Shin D. Ryoo S.-R. Hong B. H. Min D.-H. Biomedical Applications of Graphene and Graphene Oxide. Acc. Chem. Res. 2013;46:2211–2224. doi: 10.1021/ar300159f. [DOI] [PubMed] [Google Scholar]
- Georgakilas V. Otyepka M. Bourlinos A. B. Chandra V. Kim N. Kemp K. C. Hobza P. Zboril R. Kim K. S. Functionalization of Graphene: Covalent and Non-Covalent Approaches, Derivatives and Applications. Chem. Rev. 2012;112:6156–6214. doi: 10.1021/cr3000412. [DOI] [PubMed] [Google Scholar]
- Georgakilas V. Tiwari J. N. Kemp K. C. Perman J. A. Bourlinos A. B. Kim K. S. Zboril R. Noncovalent Functionalization of Graphene and Graphene Oxide for Energy Materials, Biosensing, Catalytic, and Biomedical Applications. Chem. Rev. 2016;116:5464–5519. doi: 10.1021/acs.chemrev.5b00620. [DOI] [PubMed] [Google Scholar]
- Chua C. K. Pumera M. Chemical Reduction of Graphene Oxide: A Synthetic Chemistry Viewpoint. Chem. Soc. Rev. 2014;43:291–312. doi: 10.1039/C3CS60303B. [DOI] [PubMed] [Google Scholar]
- Sutter P. W. Flege J.-I. Sutter E. A. Epitaxial Graphene on Ruthenium. Nat. Mater. 2008;7:406–411. doi: 10.1038/nmat2166. [DOI] [PubMed] [Google Scholar]
- Hernandez Y. Nicolosi V. Lotya M. Blighe F. M. Sun Z. De S. McGovern I. T. Holland B. Byrne M. Gun'Ko Y. K. Boland J. J. Niraj P. Duesberg G. Krishnamurthy S. Goodhue R. Hutchison J. Scardaci V. Ferrari A. C. Coleman J. N. High-Yield Production of Graphene by Liquid-Phase Exfoliation of Graphite. Nat. Nanotechnol. 2008;3:563–568. doi: 10.1038/nnano.2008.215. [DOI] [PubMed] [Google Scholar]
- Reina A. Jia X. Ho J. Nezich D. Son H. Bulovic V. Dresselhaus M. S. Kong J. Large Area, Few-Layer Graphene Films on Arbitrary Substrates by Chemical Vapor Deposition. Nano Lett. 2009;9:30–35. doi: 10.1021/nl801827v. [DOI] [PubMed] [Google Scholar]
- Liu N. Luo F. Wu H. Liu Y. Zhang C. Chen J. One-Step Ionic-Liquid-Assisted Electrochemical Synthesis of Ionic-Liquid-Functionalized Graphene Sheets Directly from Graphite. Adv. Funct. Mater. 2008;18:1518–1525. doi: 10.1002/adfm.200700797. [DOI] [Google Scholar]
- Subrahmanyam K. S. Panchakarla L. S. Govindaraj A. Rao C. N. R. Simple Method of Preparing Graphene Flakes by an Arc-Discharge Method. J. Phys. Chem. C. 2009;113:4257–4259. doi: 10.1021/jp900791y. [DOI] [Google Scholar]
- Wu Z.-S. Ren W. Gao L. Zhao J. Chen Z. Liu B. Tang D. Yu B. Jiang C. Cheng H.-M. Synthesis of Graphene Sheets with High Electrical Conductivity and Good Thermal Stability by Hydrogen Arc Discharge Exfoliation. ACS Nano. 2009;3:411–417. doi: 10.1021/nn900020u. [DOI] [PubMed] [Google Scholar]
- Wang X. Sun G. Routh P. Kim D.-H. Huang W. Chen P. Heteroatom-Doped Graphene Materials: Syntheses, Properties and Applications. Chem. Soc. Rev. 2014;43:7067–7098. doi: 10.1039/C4CS00141A. [DOI] [PubMed] [Google Scholar]
- Filip J. Tkac J. Is Graphene Worth Using in Biofuel Cells? Electrochim. Acta. 2014;136:340–354. doi: 10.1016/j.electacta.2014.05.119. [DOI] [Google Scholar]
- Xu J. Shui J. Wang J. Wang M. Liu H.-K. Dou S. X. Jeon I.-Y. Seo J.-M. Baek J.-B. Dai L. Sulfur–Graphene Nanostructured Cathodes via Ball-Milling for High-Performance Lithium–Sulfur Batteries. ACS Nano. 2014;8:10920–10930. doi: 10.1021/nn5047585. [DOI] [PubMed] [Google Scholar]
- Park S. Ruoff R. S. Chemical Methods for the Production of Graphenes. Nat. Nanotechnol. 2009;4:217–224. doi: 10.1038/nnano.2009.58. [DOI] [PubMed] [Google Scholar]
- Erickson K. Erni R. Lee Z. Alem N. Gannett W. Zettl A. Determination of the Local Chemical Structure of Graphene Oxide and Reduced Graphene Oxide. Adv. Mater. 2010;22:4467–4472. doi: 10.1002/adma.201000732. [DOI] [PubMed] [Google Scholar]
- Gao L. Lian C. Zhou Y. Yan L. Li Q. Zhang C. Chen L. Chen K. Graphene Oxide–DNA Based Sensors. Biosens. Bioelectron. 2014;60:22–29. doi: 10.1016/j.bios.2014.03.039. [DOI] [PubMed] [Google Scholar]
- Jung J. H. Cheon D. S. Liu F. Lee K. B. Seo T. S. A Graphene Oxide Based Immuno-Biosensor for Pathogen Detection. Angew. Chem., Int. Ed. 2010;49:5708–5711. doi: 10.1002/anie.201001428. [DOI] [PubMed] [Google Scholar]
- Hummers W. S. Offeman R. E. Preparation of Graphitic Oxide. J. Am. Chem. Soc. 1958;80:1339. doi: 10.1021/ja01539a017. [DOI] [Google Scholar]
- Dreyer D. R. Park S. Bielawski C. W. Ruoff R. S. The Chemistry of Graphene Oxide. Chem. Soc. Rev. 2010;39:228–240. doi: 10.1039/B917103G. [DOI] [PubMed] [Google Scholar]
- McAllister M. J. Li J.-L. Adamson D. H. Schniepp H. C. Abdala A. A. Liu J. Herrera-Alonso M. Milius D. L. Car R. Prud'homme R. K. Aksay I. A. Single Sheet Functionalized Graphene by Oxidation and Thermal Expansion of Graphite. Chem. Mater. 2007;19:4396–4404. doi: 10.1021/cm0630800. [DOI] [Google Scholar]
- Williams G. Seger B. Kamat P. V. TiO2-Graphene Nanocomposites. UV-Assisted Photocatalytic Reduction of Graphene Oxide. ACS Nano. 2008;2:1487–1491. doi: 10.1021/nn800251f. [DOI] [PubMed] [Google Scholar]
- Compton O. C. Nguyen S. T. Graphene Oxide, Highly Reduced Graphene Oxide, and Graphene: Versatile Building Blocks for Carbon-Based Materials. Small. 2010;6:711–723. doi: 10.1002/smll.200901934. [DOI] [PubMed] [Google Scholar]
- Bacon M. Bradley S. J. Nann T. Graphene Quantum Dots. Part. Part. Syst. Charact. 2014;31:415–428. doi: 10.1002/ppsc.201300252. [DOI] [Google Scholar]
- Li L.-s. Yan X. Colloidal Graphene Quantum Dots. J. Phys. Chem. Lett. 2010;1:2572–2576. doi: 10.1021/jz100862f. [DOI] [Google Scholar]
- Zhou S. Xu H. Gan W. Yuan Q. Graphene Quantum Dots: Recent Progress in Preparation and Fluorescence Sensing Applications. RSC Adv. 2016;6:110775–110788. doi: 10.1039/C6RA24349E. [DOI] [Google Scholar]
- Sun H. Wu L. Wei W. Qu X. Recent Advances in Graphene Quantum Dots for Sensing. Mater. Today. 2013;16:433–442. doi: 10.1016/j.mattod.2013.10.020. [DOI] [Google Scholar]
- Pan D. Zhang J. Li Z. Wu M. Hydrothermal Route for Cutting Graphene Sheets into Blue-Luminescent Graphene Quantum Dots. Adv. Mater. 2010;22:734–738. doi: 10.1002/adma.200902825. [DOI] [PubMed] [Google Scholar]
- Suzuki N. Wang Y. Elvati P. Qu Z.-B. Kim K. Jiang S. Baumeister E. Lee J. Yeom B. Bahng J. H. Lee J. Violi A. Kotov N. A. Chiral Graphene Quantum Dots. ACS Nano. 2016;10:1744–1755. doi: 10.1021/acsnano.5b06369. [DOI] [PubMed] [Google Scholar]
- Lu J. Yeo P. S. E. Gan C. K. Wu P. Loh K. P. Transforming C60 Molecules Into Graphene Quantum Dots. Nat. Nanotechnol. 2011;6:247–252. doi: 10.1038/nnano.2011.30. [DOI] [PubMed] [Google Scholar]
- Zhang Z. Zhang J. Chen N. Qu L. Graphene Quantum Dots: An Emerging Material for Energy-Related Applications and Beyond. Energy Environ. Sci. 2012;5:8869–8890. doi: 10.1039/C2EE22982J. [DOI] [Google Scholar]
- Li Y. Zhao Y. Cheng H. Hu Y. Shi G. Dai L. Qu L. Nitrogen-Doped Graphene Quantum Dots with Oxygen-Rich Functional Groups. J. Am. Chem. Soc. 2012;134:15–18. doi: 10.1021/ja206030c. [DOI] [PubMed] [Google Scholar]
- Guo Y. Han Y. Shuang S. Dong C. Rational Synthesis of Graphene–Metal Coordination Polymer Composite Nanosheet as Enhanced Materials for Electrochemical Biosensing. J. Mater. Chem. 2012;22:13166–13173. doi: 10.1039/C2JM31997G. [DOI] [Google Scholar]
- Yin P. T. Kim T.-H. Choi J.-W. Lee K.-B. Prospects for Graphene–Nanoparticle-Based Hybrid Sensors. Phys. Chem. Chem. Phys. 2013;15:12785–12799. doi: 10.1039/C3CP51901E. [DOI] [PMC free article] [PubMed] [Google Scholar]
- International Diabetes Federation, https://www.idf.org/aboutdiabetes/what-is-diabetes/facts-figures.html
- Clark L. C. Lyons C. Electrode Systems for Continuous Monitoring in Cardiovascular Surgery. Ann. N. Y. Acad. Sci. 1962;102:29–45. doi: 10.1111/j.1749-6632.1962.tb13623.x. [DOI] [PubMed] [Google Scholar]
- Witkowska Nery E. Kundys M. Jeleń P. S. Jönsson-Niedziółka M. Electrochemical Glucose Sensing: Is There Still Room for Improvement? Anal. Chem. 2016;88:11271–11282. doi: 10.1021/acs.analchem.6b03151. [DOI] [PubMed] [Google Scholar]
- Wang J., Electrochemical Glucose Biosensors, Electrochem. Sensors, Biosens. their Biomed. Appl., 2008, pp. 57–69 [Google Scholar]
- Chen C. Xie Q. Yang D. Xiao H. Fu Y. Tan Y. Yao S. Recent Advances in Electrochemical Glucose Biosensors: A Review. RSC Adv. 2013;3:4473–4491. doi: 10.1039/C2RA22351A. [DOI] [Google Scholar]
- Muguruma H. Iwasa H. Hidaka H. Hiratsuka A. Uzawa H. Mediatorless Direct Electron Transfer between Flavin Adenine Dinucleotide-Dependent Glucose Dehydrogenase and Single-Walled Carbon Nanotubes. ACS Catal. 2017;7:725–734. doi: 10.1021/acscatal.6b02470. [DOI] [Google Scholar]
- Zhao M. Gao Y. Sun J. Gao F. Mediatorless Glucose Biosensor and Direct Electron Transfer Type Glucose/Air Biofuel Cell Enabled with Carbon Nanodots. Anal. Chem. 2015;87:2615–2622. doi: 10.1021/acs.analchem.5b00012. [DOI] [PubMed] [Google Scholar]
- Bai Y.-F. Xu T.-B. Luong J. H. T. Cui H.-F. Direct Electron Transfer of Glucose Oxidase-Boron Doped Diamond Interface: A New Solution for a Classical Problem. Anal. Chem. 2014;86:4910–4918. doi: 10.1021/ac501143e. [DOI] [PubMed] [Google Scholar]
- Chen A. Chatterjee S. Nanomaterials Based Electrochemical Sensors for Biomedical Applications. Chem. Soc. Rev. 2013;42:5425–5438. doi: 10.1039/C3CS35518G. [DOI] [PubMed] [Google Scholar]
- Cai C. Chen J. Direct Electron Transfer of Glucose Oxidase Promoted by Carbon Nanotubes. Anal. Biochem. 2004;332:75–83. doi: 10.1016/j.ab.2004.05.057. [DOI] [PubMed] [Google Scholar]
- Goran J. M. Mantilla S. M. Stevenson K. J. Influence of Surface Adsorption on the Interfacial Electron Transfer of Flavin Adenine Dinucleotide and Glucose Oxidase at Carbon Nanotube and Nitrogen-Doped Carbon Nanotube Electrodes. Anal. Chem. 2013;85:1571–1581. doi: 10.1021/ac3028036. [DOI] [PubMed] [Google Scholar]
- Lin Y. Lu F. Tu Y. Ren Z. Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles. Nano Lett. 2004;4:191–195. doi: 10.1021/nl0347233. [DOI] [Google Scholar]
- Wooten M. Karra S. Zhang M. Gorski W. On the Direct Electron Transfer, Sensing, and Enzyme Activity in the Glucose Oxidase/Carbon Nanotubes System. Anal. Chem. 2013;86:752–757. doi: 10.1021/ac403250w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tsujimura S. Murata K. Akatsuka W. Exceptionally High Glucose Current on a Hierarchically Structured Porous Carbon Electrode with “Wired” Flavin Adenine Dinucleotide-Dependent Glucose Dehydrogenase. J. Am. Chem. Soc. 2014;136:14432–14437. doi: 10.1021/ja5053736. [DOI] [PubMed] [Google Scholar]
- Rafighi P. Tavahodi M. Haghighi B. Fabrication of a Third-Generation Glucose Biosensor Using Graphene-Polyethyleneimine-Gold Nanoparticles Hybrid. Sens. Actuators, B. 2016;232:454–461. doi: 10.1016/j.snb.2016.03.147. [DOI] [Google Scholar]
- Razmi H. Mohammad-Rezaei R. Graphene Quantum Dots as a New Substrate for Immobilization and Direct Electrochemistry of Glucose Oxidase: Application to Sensitive Glucose Determination. Biosens. Bioelectron. 2013;41:498–504. doi: 10.1016/j.bios.2012.09.009. [DOI] [PubMed] [Google Scholar]
- Karimi A. Othman A. Uzunoglu A. Stanciu L. Andreescu S. Graphene Based Enzymatic Bioelectrodes and Biofuel Cells. Nanoscale. 2015;7:6909–6923. doi: 10.1039/C4NR07586B. [DOI] [PubMed] [Google Scholar]
- Kim J. Park S.-J. Min D.-H. Emerging Approaches for Graphene Oxide Biosensor. Anal. Chem. 2017;89:232–248. doi: 10.1021/acs.analchem.6b04248. [DOI] [PubMed] [Google Scholar]
- Song Y. Qu K. Zhao C. Ren J. Qu X. Graphene Oxide: Intrinsic Peroxidase Catalytic Activity and Its Application to Glucose Detection. Adv. Mater. 2010;22:2206–2210. doi: 10.1002/adma.200903783. [DOI] [PubMed] [Google Scholar]
- Lipani L. Dupont B. G. R. Doungmene F. Marken F. Tyrrell R. M. Guy R. H. Ilie A. Non-Invasive, Transdermal, Path-Selective and Specific Glucose Monitoring via a Graphene-Based Platform. Nat. Nanotechnol. 2018;13:504–511. doi: 10.1038/s41565-018-0112-4. [DOI] [PubMed] [Google Scholar]
- Zhou M. Zhai Y. Dong S. Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide. Anal. Chem. 2009;81:5603–5613. doi: 10.1021/ac900136z. [DOI] [PubMed] [Google Scholar]
- Gao H. Duan H. 2D and 3D Graphene Materials: Preparation and Bioelectrochemical Applications. Biosens. Bioelectron. 2015;65:404–419. doi: 10.1016/j.bios.2014.10.067. [DOI] [PubMed] [Google Scholar]
- Wang Y. Shao Y. Matson D. W. Li J. Lin Y. Nitrogen-Doped Graphene and Its Application in Electrochemical Biosensing. ACS Nano. 2010;4:1790–1798. doi: 10.1021/nn100315s. [DOI] [PubMed] [Google Scholar]
- Küchler A. Yoshimoto M. Luginbühl S. Mavelli F. Walde P. Enzymatic Reactions in Confined Environments. Nat. Nanotechnol. 2016;11:409–420. doi: 10.1038/nnano.2016.54. [DOI] [PubMed] [Google Scholar]
- Zhu Z. Garcia-Gancedo L. Flewitt A. J. Xie H. Moussy F. Milne W. I. A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene. Sensors. 2012;12:5996–6022. doi: 10.3390/s120505996. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang J. Zhang F. Yang H. Huang X. Liu H. Zhang J. Guo S. Graphene Oxide as a Matrix for Enzyme Immobilization. Langmuir. 2010;26:6083–6085. doi: 10.1021/la904014z. [DOI] [PubMed] [Google Scholar]
- Jin L. Yang K. Yao K. Zhang S. Tao H. Lee S.-T. Liu Z. Peng R. Functionalized Graphene Oxide in Enzyme Engineering: A Selective Modulator for Enzyme Activity and Thermostability. ACS Nano. 2012;6:4864–4875. doi: 10.1021/nn300217z. [DOI] [PubMed] [Google Scholar]
- Pavlidis I. V. Patila M. Bornscheuer U. T. Gournis D. Stamatis H. Graphene-Based Nanobiocatalytic Systems: Recent Advances and Future Prospects. Trends Biotechnol. 2014;32:312–320. doi: 10.1016/j.tibtech.2014.04.004. [DOI] [PubMed] [Google Scholar]
- Singh S. K. Singh M. K. Kulkarni P. P. Sonkar V. K. Grácio J. J. A. Dash D. Amine-Modified Graphene: Thrombo-Protective Safer Alternative to Graphene Oxide for Biomedical Applications. ACS Nano. 2012;6:2731–2740. doi: 10.1021/nn300172t. [DOI] [PubMed] [Google Scholar]
- Wang Z. Zhou X. Zhang J. Boey F. Zhang H. Direct Electrochemical Reduction of Single-Layer Graphene Oxide and Subsequent Functionalization with Glucose Oxidase. J. Phys. Chem. C. 2009;113:14071–14075. doi: 10.1021/jp906348x. [DOI] [Google Scholar]
- Liu Y. Yu D. Zeng C. Miao Z. Dai L. Biocompatible Graphene Oxide-Based Glucose Biosensors. Langmuir. 2010;26:6158–6160. doi: 10.1021/la100886x. [DOI] [PubMed] [Google Scholar]
- Li Q. Fan F. Wang Y. Feng W. Ji P. Enzyme Immobilization on Carboxyl-Functionalized Graphene Oxide for Catalysis in Organic Solvent. Ind. Eng. Chem. Res. 2013;52:6343–6348. doi: 10.1021/ie400558u. [DOI] [Google Scholar]
- Rusling J. F. Forster R. J. Electrochemical Catalysis with Redox Polymer and Polyion–Protein Films. J. Colloid Interface Sci. 2003;262:1–15. doi: 10.1016/S0021-9797(03)00148-6. [DOI] [PubMed] [Google Scholar]
- Newman J. D. Turner A. P. F. Home Blood Glucose Biosensors: A Commercial Perspective. Biosens. Bioelectron. 2005;20:2435–2453. doi: 10.1016/j.bios.2004.11.012. [DOI] [PubMed] [Google Scholar]
- Li D. Zhang W. Yu X. Wang Z. Su Z. Wei G. When Biomolecules Meet Graphene: From Molecular Level Interactions to Material Design and Applications. Nanoscale. 2016;8:19491–19509. doi: 10.1039/C6NR07249F. [DOI] [PubMed] [Google Scholar]
- Sreeprasad T. S. Berry V. How do the Electrical Properties of Graphene Change with its Functionalization? Small. 2013;9:341–350. doi: 10.1002/smll.201202196. [DOI] [PubMed] [Google Scholar]
- Kang X. Wang J. Wu H. Aksay I. A. Liu J. Lin Y. Glucose Oxidase–Graphene–Chitosan Modified Electrode for Direct Electrochemistry and Glucose Sensing. Biosens. Bioelectron. 2009;25:901–905. doi: 10.1016/j.bios.2009.09.004. [DOI] [PubMed] [Google Scholar]
- Guler M. Dilmac Y. Palladium nanoparticles decorated (3-aminopropyl) triethoxysilane functionalized reduced graphene oxide for electrochemical determination of glucose and hydrogen peroxide. J. Electroanal. Chem. 2019;834:49–55. doi: 10.1016/j.jelechem.2018.12.052. [DOI] [Google Scholar]
- Shan C. Yang H. Han D. Zhang Q. Ivaska A. Niu L. Graphene/AuNPs/Chitosan Nanocomposites Film for Glucose Biosensing. Biosens. Bioelectron. 2010;25:1070–1074. doi: 10.1016/j.bios.2009.09.024. [DOI] [PubMed] [Google Scholar]
- Singh J. Khanra P. Kuila T. Srivastava M. Das A. K. Kim N. H. Jung B. J. Kim D. Y. Lee S. H. Lee D. W. Kim D.-G. Lee J. H. Preparation of Sulfonated Poly(Ether–Ether–Ketone) Functionalized Ternary Graphene/AuNPs/Chitosan Nanocomposite for Efficient Glucose Biosensor. Process Biochem. 2013;48:1724–1735. doi: 10.1016/j.procbio.2013.07.025. [DOI] [Google Scholar]
- Zheng J. He Y. Sheng Q. Zhang H. DNA as a Linker for Biocatalytic Deposition of Au Nanoparticles on Graphene and Its Application in Glucose Detection. J. Mater. Chem. 2011;21:12873–12879. doi: 10.1039/C1JM11707F. [DOI] [Google Scholar]
- Liang B. Fang L. Yang G. Hu Y. Guo X. Ye X. Direct Electron Transfer Glucose Biosensor Based on Glucose Oxidase Self-Assembled on Electrochemically Reduced Carboxyl Graphene. Biosens. Bioelectron. 2013;43:131–136. doi: 10.1016/j.bios.2012.11.040. [DOI] [PubMed] [Google Scholar]
- Cui M. Xu B. Hu C. Shao H. B. Qu L. Direct electrochemistry and electrocatalysis of glucose oxidase on three-dimensional interpenetrating, porous graphene modified electrode. Electrochim. Acta. 2013;98:48–53. doi: 10.1016/j.electacta.2013.03.040. [DOI] [Google Scholar]
- Qian L. Lu L. Three Dimensional Porous Graphene–Chitosan Composites from Ice-Induced Assembly for Direct Electron Transfer and Electrocatalysis of Glucose Oxidase. RSC Adv. 2014;4:38273–38280. doi: 10.1039/C4RA07707E. [DOI] [Google Scholar]
- Dey R. S. Raj C. R. A Hybrid Functional Nanoscaffold Based on Reduced Graphene Oxide–ZnO for the Development of an Amperometric Biosensing Platform. RSC Adv. 2013;3:25858–25864. doi: 10.1039/C3RA43773F. [DOI] [Google Scholar]
- Vilian A. T. E. Chen S.-M. Ali M. A. Al-Hemaid F. M. A. Direct Electrochemistry of Glucose Oxidase Immobilized on ZrO2 Nanoparticles-Decorated Reduced Graphene Oxide Sheets for a Glucose Biosensor. RSC Adv. 2014;4:30358–30367. doi: 10.1039/C4RA04350B. [DOI] [Google Scholar]
- Hossain M. F. Park J. Y. Amperometric Glucose Biosensor Based on Pt-Pd Nanoparticles Supported by Reduced Graphene Oxide and Integrated with Glucose Oxidase. Electroanalysis. 2014;26:940–951. doi: 10.1002/elan.201400018. [DOI] [Google Scholar]
- Palanisamy S. Karuppiah C. Chen S.-M. Direct Electrochemistry and Electrocatalysis of Glucose Oxidase Immobilized on Reduced Graphene Oxide and Silver Nanoparticles Nanocomposite Modified Electrode. Colloids Surf., B. 2014;114:164–169. doi: 10.1016/j.colsurfb.2013.10.006. [DOI] [PubMed] [Google Scholar]
- Yu Y. Chen Z. He S. Zhang B. Li X. Yao M. Direct Electron Transfer of Glucose Oxidase and Biosensing For Glucose Based on PDDA-Capped Gold Nanoparticle Modified Graphene/Multi-Walled Carbon Nanotubes Electrode. Biosens. Bioelectron. 2014;52:147–152. doi: 10.1016/j.bios.2013.08.043. [DOI] [PubMed] [Google Scholar]
- Tabrizi M. A. Varkani J. N. Green Synthesis of Reduced Graphene Oxide Decorated with Gold Nanoparticles and its Glucose Sensing Application. Sens. Actuators, B. 2014;202:475–482. doi: 10.1016/j.snb.2014.05.099. [DOI] [Google Scholar]
- Teymourian H. Salimi A. Firoozi S. A High Performance Electrochemical Biosensing Platform for Glucose Detection and IgE Aptasensing Based on Fe3O4/Reduced Graphene Oxide Nanocomposite. Electroanalysis. 2014;26:129–138. doi: 10.1002/elan.201300496. [DOI] [Google Scholar]
- Vilian A. T. E. Mani V. Chen S.-M. Dinesh B. Huang S.-T. The Immobilization of Glucose Oxidase at Manganese Dioxide Particles-Decorated Reduced Graphene Oxide Sheets for the Fabrication of a Glucose Biosensor. Ind. Eng. Chem. Res. 2014;53:15582–15589. doi: 10.1021/ie502430d. [DOI] [Google Scholar]
- Hwa K.-Y. Subramani B. Synthesis of Zinc Oxide Nanoparticles on Graphene–Carbon Nanotube Hybrid for Glucose Biosensor Applications. Biosens. Bioelectron. 2014;62:127–133. doi: 10.1016/j.bios.2014.06.023. [DOI] [PubMed] [Google Scholar]
- Palanisamy S. Cheemalapati S. Chen S.-M. Amperometric Glucose Biosensor Based on Glucose Oxidase Dispersed in Multiwalled Carbon Nanotubes/Graphene Oxide Hybrid Biocomposite. Mater. Sci. Eng., C. 2014;34:207–213. doi: 10.1016/j.msec.2013.09.011. [DOI] [PubMed] [Google Scholar]
- Piao Y. Han D. J. Seo T. S. Highly Conductive Graphite Nanoparticle Based Enzyme Biosensor for Electrochemical Glucose Detection. Sens. Actuators, B. 2014;194:454–459. doi: 10.1016/j.snb.2013.12.045. [DOI] [Google Scholar]
- Devasenathipathy R. Mani V. Chen S.-M. Huang S.-T. Huang T.-T. Lin C.-M. Hwa K.-Y. Chen T.-Y. Chen B.-J. Glucose Biosensor Based On Glucose Oxidase Immobilized At Gold Nanoparticles Decorated Graphene-Carbon Nanotubes. Enzyme Microb. Technol. 2015;78:40–45. doi: 10.1016/j.enzmictec.2015.06.006. [DOI] [PubMed] [Google Scholar]
- Nayak P. Santhosh P. N. Ramaprabhu S. Synthesis of Au-MWCNT–Graphene Hybrid Composite for the Rapid Detection of H2O2 and Glucose. RSC Adv. 2014;4:41670–41677. doi: 10.1039/C4RA05353B. [DOI] [Google Scholar]
- Terse-Thakoor T. Komori K. Ramnani P. Lee I. Mulchandani A. Electrochemically Functionalized Seamless Three-Dimensional Graphene-Carbon Nanotube Hybrid for Direct Electron Transfer of Glucose Oxidase and Bioelectrocatalysis. Langmuir. 2015;31:13054–13061. doi: 10.1021/acs.langmuir.5b03273. [DOI] [PubMed] [Google Scholar]
- Liang B. Fang L. Hu Y. Yang G. Zhu Q. Ye X. Fabrication and Application of Flexible Graphene Silk Composite Film Electrodes Decorated with Spiky Pt Nanospheres. Nanoscale. 2014;6:4264–4274. doi: 10.1039/C3NR06057H. [DOI] [PubMed] [Google Scholar]
- Fang Y. Zhang D. Guo Y. Guo Y. Chen Q. Simple One-Pot Preparation of Chitosan-Reduced Graphene Oxide-Au Nanoparticles Hybrids for Glucose Sensing. Sens. Actuators, B. 2015;221:265–272. doi: 10.1016/j.snb.2015.06.098. [DOI] [Google Scholar]
- Zhang W. Li X. Zou R. Wu H. Shi H. Yu S. Liu Y. Multifunctional Glucose Biosensors from Fe3O4 Nanoparticles Modified Chitosan/Graphene Nanocomposites. Sci. Rep. 2015;5:11129. doi: 10.1038/srep11129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hossain M. F. Park J. Y. Plain to Point Network Reduced Graphene Oxide-Activated Carbon Composites Decorated with Platinum Nanoparticles for Urine Glucose Detection. Sci. Rep. 2016;6:21009. doi: 10.1038/srep21009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Palanisamy S. Devasenathipathy R. Chen S.-M. Ajmal Ali M. Karuppiah C. Balakumar V. Prakash P. Elshikh M. S. Al-Hemaid F. M. A. Direct Electrochemistry of Glucose Oxidase at Reduced Graphene Oxide and β-Cyclodextrin Composite Modified Electrode and Application for Glucose Biosensing. Electroanalysis. 2015;27:2412–2420. doi: 10.1002/elan.201500150. [DOI] [Google Scholar]
- Thirumalraj B. Palanisamy S. Chen S.-M. Yang C.-Y. Periakaruppan P. Lou B.-S. Direct Electrochemistry of Glucose Oxidase and Sensing of Glucose at a Glassy Carbon Electrode Modified with a Reduced Graphene Oxide/Fullerene-C60 Composite. RSC Adv. 2015;5:77651–77657. doi: 10.1039/C5RA12018G. [DOI] [Google Scholar]
- Qi M. Zhang Y. Cao C. Lu Y. Liu G. Increased Sensitivity of Extracellular Glucose Monitoring Based on AuNP Decorated GO Nanocomposites. RSC Adv. 2016;6:39180–39187. doi: 10.1039/C6RA04975C. [DOI] [Google Scholar]
- Tehrani F. Bavarian B. Facile and Scalable Disposable Sensor Based on Laser Engraved Graphene for Electrochemical Detection of Glucose. Sci. Rep. 2016;6:27975. doi: 10.1038/srep27975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vijayaraj K. Hong S. W. Jin S.-H. Chang S.-C. Park D.-S. Fabrication of a Novel Disposable Glucose Biosensor Using an Electrochemically Reduced Graphene Oxide–Glucose Oxidase Biocomposite. Anal. Methods. 2016;8:6974–6981. doi: 10.1039/C6AY02032A. [DOI] [Google Scholar]
- Mascagni D. B. T. Miyazaki C. M. da Cruz N. C. de Moraes M. L. Riul A. Ferreira M. Layer-by-Layer Assembly of Functionalized Reduced Graphene Oxide for Direct Electrochemistry and Glucose Detection. Mater. Sci. Eng., C. 2016;68:739–745. doi: 10.1016/j.msec.2016.06.001. [DOI] [PubMed] [Google Scholar]
- Wu S. Su F. Dong X. Ma C. Pang L. Peng D. Wang M. He L. Zhang Z. Development of Glucose Biosensors Based on Plasma Polymerization-Assisted Nanocomposites of Polyaniline, Tin Oxide, and Three-Dimensional Reduced Graphene Oxide. Appl. Surf. Sci. 2017;401:262–270. doi: 10.1016/j.apsusc.2017.01.024. [DOI] [Google Scholar]
- Liu Y. Zhang X. He D. Ma F. Fu Q. Hu Y. An Amperometric Glucose Biosensor Based on a MnO2/Graphene Composite Modified Electrode. RSC Adv. 2016;6:18654–18661. doi: 10.1039/C6RA02680J. [DOI] [Google Scholar]
- Halder A. Zhang M. Chi Q. Electroactive and Biocompatible Functionalization of Graphene for The Development of Biosensing Platforms. Biosens. Bioelectron. 2017;87:764–771. doi: 10.1016/j.bios.2016.09.030. [DOI] [PubMed] [Google Scholar]
- Osikoya A. O. Parlak O. Murugan N. A. Dikio E. D. Moloto H. Uzun L. Turner A. P. F. Tiwari A. Acetylene-Sourced CVD-Synthesised Catalytically Active Graphene for Electrochemical Biosensing. Biosens. Bioelectron. 2017;89:496–504. doi: 10.1016/j.bios.2016.03.063. [DOI] [PubMed] [Google Scholar]
- Pakapongpan S. Poo-arporn R. P. Self-Assembly of Glucose Oxidase on Reduced Graphene Oxide-Magnetic Nanoparticles Nanocomposite-Based Direct Electrochemistry for Reagentless Glucose Biosensor. Mater. Sci. Eng., C. 2017;76:398–405. doi: 10.1016/j.msec.2017.03.031. [DOI] [PubMed] [Google Scholar]
- Liu J. Wang X. Wang T. Li D. Xi F. Wang J. Wang E. Functionalization of Monolithic and Porous Three-Dimensional Graphene by One-Step Chitosan Electrodeposition for Enzymatic Biosensor. ACS Appl. Mater. Interfaces. 2014;6:19997–20002. doi: 10.1021/am505547f. [DOI] [PubMed] [Google Scholar]
- Wang Y. Liu X.-y. Xu X. Yang Y. Huang L.-h. He Z.-y. Xu Y.-h. Chen J.-j. Feng Z.-s. Preparation and Characterization of Reduced Graphene Oxide/Fe3O4 Nanocomposite by a Facile In situ Deposition Method for Glucose Biosensor Applications. Mater. Res. Bull. 2018;101:340–346. doi: 10.1016/j.materresbull.2018.01.035. [DOI] [Google Scholar]
- Çakıroğlu B. Özacar M. Tannic Acid Modified Electrochemical Biosensor for Glucose Sensing Based on Direct Electrochemistry. Electroanalysis. 2017;29:2719–2726. doi: 10.1002/elan.201700420. [DOI] [Google Scholar]
- Akkaya B. Çakiroğlu B. Özacar M. Tannic Acid-Reduced Graphene Oxide Deposited with Pt Nanoparticles for Switchable Bioelectronics and Biosensors Based on Direct Electrochemistry. ACS Sustainable Chem. Eng. 2018;6:3805–3814. doi: 10.1021/acssuschemeng.7b04164. [DOI] [Google Scholar]
- Ianniello R. M. Lindsay T. J. Yacynych A. M. Differential Pulse Voltammetric Study of Direct Electron Transfer in Glucose Oxidase Chemically Modified Graphite Electrodes. Anal. Chem. 1982;54:1098–1101. doi: 10.1021/ac00244a019. [DOI] [Google Scholar]
- Wilson G. S. Native Glucose Oxidase does not Undergo Direct Electron Transfer. Biosens. Bioelectron. 2016;82:7–8. doi: 10.1016/j.bios.2016.04.083. [DOI] [PubMed] [Google Scholar]
- Liang B. Guo X. Fang L. Hu Y. Yang G. Zhu Q. Wei J. Ye X. Study of Direct Electron Transfer and Enzyme Activity of Glucose Oxidase on Graphene Surface. Electrochem. Commun. 2015;50:1–5. doi: 10.1016/j.elecom.2014.10.016. [DOI] [Google Scholar]
- Laviron E. General Expression of the Linear Potential Sweep Voltammogram in the Case Of Diffusionless Electrochemical Systems. J. Electroanal. Chem. Interfacial Electrochem. 1979;101:19–28. doi: 10.1016/S0022-0728(79)80075-3. [DOI] [Google Scholar]
- Shan C. Yang H. Song J. Han D. Ivaska A. Niu L. Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene. Anal. Chem. 2009;81:2378–2382. doi: 10.1021/ac802193c. [DOI] [PubMed] [Google Scholar]
- Guler M. Turkoglu V. Kivanc M. R. A Novel Enzymatic Glucose Biosensor and Nonenzymatic Hydrogen Peroxide Sensor Based on (3-Aminopropyl) Triethoxysilane Functionalized Reduced Graphene Oxide. Electroanalysis. 2017;29:2507–2515. doi: 10.1002/elan.201700417. [DOI] [Google Scholar]
- Unnikrishnan B. Palanisamy S. Chen S.-M. A Simple Electrochemical Approach to Fabricate a Glucose Biosensor Based on Graphene–Glucose Oxidase Biocomposite. Biosens. Bioelectron. 2013;39:70–75. doi: 10.1016/j.bios.2012.06.045. [DOI] [PubMed] [Google Scholar]
- Ravenna Y. Xia L. Gun J. Mikhaylov A. A. Medvedev A. G. Lev O. Alfonta L. Biocomposite Based on Reduced Graphene Oxide Film Modified with Phenothiazone and Flavin Adenine Dinucleotide-Dependent Glucose Dehydrogenase for Glucose Sensing and Biofuel Cell Applications. Anal. Chem. 2015;87:9567–9571. doi: 10.1021/acs.analchem.5b02949. [DOI] [PubMed] [Google Scholar]
- Liu J. Kong N. Li A. Luo X. Cui L. Wang R. Feng S. Graphene Bridged Enzyme Electrodes for Glucose Biosensing Application. Analyst. 2013;138:2567–2575. doi: 10.1039/C3AN36929C. [DOI] [PubMed] [Google Scholar]
- Zhang X. Liao Q. Chu M. Liu S. Zhang Y. Structure Effect on Graphene-Modified Enzyme Electrode Glucose Sensors. Biosens. Bioelectron. 2014;52:281–287. doi: 10.1016/j.bios.2013.07.022. [DOI] [PubMed] [Google Scholar]
- Guo J. Zhang T. Hu C. Fu L. A Three-Dimensional Nitrogen-Doped Graphene Structure: A Highly Efficient Carrier of Enzymes for Biosensors. Nanoscale. 2015;7:1290–1295. doi: 10.1039/C4NR05325G. [DOI] [PubMed] [Google Scholar]
- Manoj D. Theyagarajan K. Saravanakumar D. Senthilkumar S. Thenmozhi K. Aldehyde Functionalized Ionic Liquid on Electrochemically Reduced Graphene Oxide as a Versatile Platform for Covalent Immobilization of Biomolecules and Biosensing. Biosens. Bioelectron. 2018;103:104–112. doi: 10.1016/j.bios.2017.12.030. [DOI] [PubMed] [Google Scholar]
- Bharath G. Madhu R. Chen S.-M. Veeramani V. Balamurugan A. Mangalaraj D. Viswanathan C. Ponpandian N. Enzymatic Electrochemical Glucose Biosensors by Mesoporous 1D Hydroxyapatite-on-2D Reduced Graphene Oxide. J. Mater. Chem. B. 2015;3:1360–1370. doi: 10.1039/C4TB01651C. [DOI] [PubMed] [Google Scholar]
- Al-Sagur H. Komathi S. Khan M. A. Gurek A. G. Hassan A. A Novel Glucose Sensor Using Lutetium Phthalocyanine as Redox Mediator in Reduced Graphene Oxide Conducting Polymer Multifunctional Hydrogel. Biosens. Bioelectron. 2017;92:638–645. doi: 10.1016/j.bios.2016.10.038. [DOI] [PubMed] [Google Scholar]
- Nguyen K. T. Zhao Y. Integrated Graphene/Nanoparticle Hybrids for Biological and Electronic Applications. Nanoscale. 2014;6:6245–6266. doi: 10.1039/C4NR00612G. [DOI] [PubMed] [Google Scholar]
- Lu J. Do I. Drzal L. T. Worden R. M. Lee I. Nanometal-Decorated Exfoliated Graphite Nanoplatelet Based Glucose Biosensors with High Sensitivity and Fast Response. ACS Nano. 2008;2:1825–1832. doi: 10.1021/nn800244k. [DOI] [PubMed] [Google Scholar]
- Jin L. Meng Z. Zhang Y. Cai S. Zhang Z. Li C. Shang L. Shen Y. Ultrasmall Pt Nanoclusters as Robust Peroxidase Mimics for Colorimetric Detection of Glucose in Human Serum. ACS Appl. Mater. Interfaces. 2017;9:10027–10033. doi: 10.1021/acsami.7b01616. [DOI] [PubMed] [Google Scholar]
- Wang Q. Cui X. Chen J. Zheng X. Liu C. Xue T. Wang H. Jin Z. Qiao L. Zheng W. Well-Dispersed Palladium Nanoparticles on Graphene Oxide as a Non-Enzymatic Glucose Sensor. RSC Adv. 2012;2:6245–6249. doi: 10.1039/C2RA20425H. [DOI] [Google Scholar]
- Luo J. Jiang S. Zhang H. Jiang J. Liu X. A Novel Non-Enzymatic Glucose Sensor Based On Cu Nanoparticle Modified Graphene Sheets Electrode. Anal. Chim. Acta. 2012;709:47–53. doi: 10.1016/j.aca.2011.10.025. [DOI] [PubMed] [Google Scholar]
- Palanisamy S. Vilian A. E. Chen S.-M. Direct Electrochemistry of Glucose Oxidase at Reduced Graphene Oxide/Zinc Oxide Composite Modified Electrode for Glucose Sensor. Int. J. Electrochem. Sci. 2012;7:2153–2163. [Google Scholar]
- Zhao Y. Li W. Pan L. Zhai D. Wang Y. Li L. Cheng W. Yin W. Wang X. Xu J.-B. Shi Y. ZnO-Nanorods/Graphene Heterostructure: A Direct Electron Transfer Glucose Biosensor. Sci. Rep. 2016;6:32327. doi: 10.1038/srep32327. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Song J. Xu L. Zhou C. Xing R. Dai Q. Liu D. Song H. Synthesis of Graphene Oxide Based CuO Nanoparticles Composite Electrode for Highly Enhanced Nonenzymatic Glucose Detection. ACS Appl. Mater. Interfaces. 2013;5:12928–12934. doi: 10.1021/am403508f. [DOI] [PubMed] [Google Scholar]
- Yuan B. Xu C. Deng D. Xing Y. Liu L. Pang H. Zhang D. Graphene Oxide/Nickel Oxide Modified Glassy Carbon Electrode for Supercapacitor and Nonenzymatic Glucose Sensor. Electrochim. Acta. 2013;88:708–712. doi: 10.1016/j.electacta.2012.10.102. [DOI] [Google Scholar]
- Teymourian H. Salimi A. Khezrian S. Fe3O4 Magnetic Nanoparticles/Reduced Graphene Oxide Nanosheets as a Novel Electrochemical and Bioeletrochemical Sensing Platform. Biosens. Bioelectron. 2013;49:1–8. doi: 10.1016/j.bios.2013.04.034. [DOI] [PubMed] [Google Scholar]
- Wang Q. Zhang X. Huang L. Zhang Z. Dong S. One-Pot Synthesis of Fe3O4 Nanoparticle Loaded 3D Porous Graphene Nanocomposites with Enhanced Nanozyme Activity for Glucose Detection. ACS Appl. Mater. Interfaces. 2017;9:7465–7471. doi: 10.1021/acsami.6b16034. [DOI] [PubMed] [Google Scholar]
- Devadoss A. Sudhagar P. Das S. Lee S. Y. Terashima C. Nakata K. Fujishima A. Choi W. Kang Y. S. Paik U. Synergistic Metal–Metal Oxide Nanoparticles Supported Electrocatalytic Graphene for Improved Photoelectrochemical Glucose Oxidation. ACS Appl. Mater. Interfaces. 2014;6:4864–4871. doi: 10.1021/am4058925. [DOI] [PubMed] [Google Scholar]
- Holland J. T. Lau C. Brozik S. Atanassov P. Banta S. Engineering of Glucose Oxidase for Direct Electron Transfer via Site-Specific Gold Nanoparticle Conjugation. J. Am. Chem. Soc. 2011;133:19262–19265. doi: 10.1021/ja2071237. [DOI] [PubMed] [Google Scholar]
- Yehezkeli O. Tel-Vered R. Raichlin S. Willner I. Nano-Engineered Flavin-Dependent Glucose Dehydrogenase/Gold Nanoparticle-Modified Electrodes for Glucose Sensing and Biofuel Cell Applications. ACS Nano. 2011;5:2385–2391. doi: 10.1021/nn200313t. [DOI] [PubMed] [Google Scholar]
- Xiao Y. Patolsky F. Katz E. Hainfeld J. F. Willner I. “Plugging into Enzymes”: Nanowiring of Redox Enzymes by a Gold Nanoparticle. Science. 2003;299:1877–1881. doi: 10.1126/science.1080664. [DOI] [PubMed] [Google Scholar]
- Wang X. Zhang X. Electrochemical Co-Reduction Synthesis of Graphene/Nano-Gold Composites and its Application to Electrochemical Glucose Biosensor. Electrochim. Acta. 2013;112:774–782. doi: 10.1016/j.electacta.2013.09.036. [DOI] [Google Scholar]
- Claussen J. C. Kumar A. Jaroch D. B. Khawaja M. H. Hibbard A. B. Porterfield D. M. Fisher T. S. Nanostructuring Platinum Nanoparticles on Multilayered Graphene Petal Nanosheets for Electrochemical Biosensing. Adv. Funct. Mater. 2012;22:3399–3405. doi: 10.1002/adfm.201200551. [DOI] [Google Scholar]
- Zaleska-Medynska A. Marchelek M. Diak M. Grabowska E. Noble Metal-Based Bimetallic Nanoparticles: The Effect of the Structure on the Optical, Catalytic and Photocatalytic Properties. Adv. Colloid Interface Sci. 2016;229:80–107. doi: 10.1016/j.cis.2015.12.008. [DOI] [PubMed] [Google Scholar]
- Park S. Boo H. Chung T. D. Electrochemical Non-Enzymatic Glucose Sensors. Anal. Chim. Acta. 2006;556:46–57. doi: 10.1016/j.aca.2005.05.080. [DOI] [PubMed] [Google Scholar]
- Zoldák G. Zubrik A. Musatov A. Stupák M. Sedlák E. Irreversible Thermal Denaturation of Glucose Oxidase from Aspergillus niger is the Transition to the Denatured State with Residual Structure. J. Biol. Chem. 2004;279:47601–47609. doi: 10.1074/jbc.M406883200. [DOI] [PubMed] [Google Scholar]
- Tian K. Prestgard M. Tiwari A. A Review of Recent Advances in Nonenzymatic Glucose Sensors. Mater. Sci. Eng., C. 2014;41:100–118. doi: 10.1016/j.msec.2014.04.013. [DOI] [PubMed] [Google Scholar]
- (a) Tee S. Y. Teng C. P. Ye E. Metal Nanostructures for Non-Enzymatic Glucose Sensing. Mater. Sci. Eng., C. 2017;70:1018–1030. doi: 10.1016/j.msec.2016.04.009. [DOI] [PubMed] [Google Scholar]; (b) Zaidi S. A. Shin J. H. Recent Developments in Nanostructure Based Electrochemical Glucose Sensors. Talanta. 2016;149:30–42. doi: 10.1016/j.talanta.2015.11.033. [DOI] [PubMed] [Google Scholar]
- Deepalakshmi T. Tran D. T. Kim N. H. Chong K. T. Lee J. H. Nitrogen-Doped Graphene-Encapsulated Nickel Cobalt Nitride as a Highly Sensitive and Selective Electrode for Glucose and Hydrogen Peroxide Sensing Applications. ACS Appl. Mater. Interfaces. 2018;10:35847–35858. doi: 10.1021/acsami.8b15069. [DOI] [PubMed] [Google Scholar]
- Hoa L. T. Sun K. G. Hur S. H. Highly Sensitive Non-Enzymatic Glucose Sensor Based on Pt Nanoparticle Decorated Graphene Oxide Hydrogel. Sens. Actuators, B. 2015;210:618–623. doi: 10.1016/j.snb.2015.01.020. [DOI] [Google Scholar]
- Jiang D. Liu Q. Wang K. Qian J. Dong X. Yang Z. Du X. Qiu B. Enhanced Non-Enzymatic Glucose Sensing Based on Copper Nanoparticles Decorated Nitrogen-Doped Graphene. Biosens. Bioelectron. 2014;54:273–278. doi: 10.1016/j.bios.2013.11.005. [DOI] [PubMed] [Google Scholar]
- Ju L. Wu G. Lu B. Li X. Wu H. Liu A. Non-Enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide. Electroanalysis. 2016;28:2543–2551. doi: 10.1002/elan.201600100. [DOI] [Google Scholar]
- Gowthaman N. S. K. Raj M. A. John S. A. Nitrogen-Doped Graphene as a Robust Scaffold for the Homogeneous Deposition of Copper Nanostructures: A Nonenzymatic Disposable Glucose Sensor. ACS Sustainable Chem. Eng. 2017;5:1648–1658. doi: 10.1021/acssuschemeng.6b02390. [DOI] [Google Scholar]
- Gao H. Xiao F. Ching C. B. Duan H. One-Step Electrochemical Synthesis of PtNi Nanoparticle-Graphene Nanocomposites for Nonenzymatic Amperometric Glucose Detection. ACS Appl. Mater. Interfaces. 2011;3:3049–3057. doi: 10.1021/am200563f. [DOI] [PubMed] [Google Scholar]
- Sheng Q. Liu D. Zheng J. NiCo Alloy Nanoparticles Anchored on Polypyrrole/Reduced Graphene Oxide Nanocomposites for Nonenzymatic Glucose Sensing. New J. Chem. 2016;40:6658–6665. doi: 10.1039/C6NJ01264G. [DOI] [Google Scholar]
- Hsu Y.-W. Hsu T.-K. Sun C.-L. Nien Y.-T. Pu N.-W. Ger M.-D. Synthesis of CuO/Graphene Nanocomposites for Nonenzymatic Electrochemical Glucose Biosensor Applications. Electrochim. Acta. 2012;82:152–157. doi: 10.1016/j.electacta.2012.03.094. [DOI] [Google Scholar]
- Dong X.-C. Xu H. Wang X.-W. Huang Y.-X. Chan-Park M. B. Zhang H. Wang L.-H. Huang W. Chen P. 3D Graphene–Cobalt Oxide Electrode for High-Performance Supercapacitor and Enzymeless Glucose Detection. ACS Nano. 2012;6:3206–3213. doi: 10.1021/nn300097q. [DOI] [PubMed] [Google Scholar]
- Wang X. Dong X. Wen Y. Li C. Xiong Q. Chen P. A Graphene–Cobalt Oxide Based Needle Electrode for Non-Enzymatic Glucose Detection in Micro-Droplets. Chem. Commun. 2012;48:6490–6492. doi: 10.1039/C2CC32674D. [DOI] [PubMed] [Google Scholar]
- Xiao F. Li Y. Gao H. Ge S. Duan H. Growth of Coral-Like PtAu–MnO2 Binary Nanocomposites on Free-Standing Graphene Paper for Flexible Nonenzymatic Glucose Sensors. Biosens. Bioelectron. 2013;41:417–423. doi: 10.1016/j.bios.2012.08.062. [DOI] [PubMed] [Google Scholar]
- Liu M. Liu R. Chen W. Graphene Wrapped Cu2O Nanocubes: Non-Enzymatic Electrochemical Sensors for the Detection of Glucose and Hydrogen Peroxide with Enhanced Stability. Biosens. Bioelectron. 2013;45:206–212. doi: 10.1016/j.bios.2013.02.010. [DOI] [PubMed] [Google Scholar]
- He Y. Zheng J. One-Pot Ultrasonic-Electrodeposition of Copper–Graphene Nanoflowers in Ethaline for Glucose Sensing. Anal. Methods. 2013;5:767–772. doi: 10.1039/C2AY26213D. [DOI] [Google Scholar]
- Wu G.-h. Song X.-h. Wu Y.-F. Chen X.-m. Luo F. Chen X. Non-Enzymatic Electrochemical Glucose Sensor Based on Platinum Nanoflowers Supported on Graphene Oxide. Talanta. 2013;105:379–385. doi: 10.1016/j.talanta.2012.10.066. [DOI] [PubMed] [Google Scholar]
- Si P. Dong X.-C. Chen P. Kim D.-H. A Hierarchically Structured Composite of Mn3O4/3D Graphene Foam for Flexible Nonenzymatic Biosensors. J. Mater. Chem. B. 2013;1:110–115. doi: 10.1039/C2TB00073C. [DOI] [PubMed] [Google Scholar]
- Dhara K. Stanley J. Ramachandran T. Nair B. G. Babu T. G. S. Pt-CuO Nanoparticles Decorated Reduced Graphene Oxide for the Fabrication of Highly Sensitive Non-Enzymatic Disposable Glucose Sensor. Sens. Actuators, B. 2014;195:197–205. doi: 10.1016/j.snb.2014.01.044. [DOI] [Google Scholar]
- Subramanian P. Niedziolka-Jonsson J. Lesniewski A. Wang Q. Li M. Boukherroub R. Szunerits S. Preparation of Reduced Graphene Oxide–Ni(OH)2 Composites by Electrophoretic Deposition: Application for Non-Enzymatic Glucose Sensing. J. Mater. Chem. A. 2014;2:5525–5533. doi: 10.1039/C4TA00123K. [DOI] [Google Scholar]
- Li M. Bo X. Zhang Y. Han C. Guo L. One-Pot Ionic Liquid-Assisted Synthesis of Highly Dispersed PtPd Nanoparticles/Reduced Graphene Oxide Composites for Nonenzymatic Glucose Detection. Biosens. Bioelectron. 2014;56:223–230. doi: 10.1016/j.bios.2014.01.030. [DOI] [PubMed] [Google Scholar]
- Zhan B. Liu C. Chen H. Shi H. Wang L. Chen P. Huang W. Dong X. Free-Standing Electrochemical Electrode Based on Ni(OH)2/3D Graphene Foam for Nonenzymatic Glucose Detection. Nanoscale. 2014;6:7424–7429. doi: 10.1039/C4NR01611D. [DOI] [PubMed] [Google Scholar]
- Hu Y. He F. Ben A. Chen C. Synthesis of Hollow Pt–Ni–Graphene Nanostructures for Nonenzymatic Glucose Detection. J. Electroanal. Chem. 2014;726:55–61. doi: 10.1016/j.jelechem.2014.05.012. [DOI] [Google Scholar]
- Alizadeh T. Mirzagholipur S. A Nafion-Free Non-Enzymatic Amperometric Glucose Sensor Based on Copper Oxide Nanoparticles–Graphene Nanocomposite. Sens. Actuators, B. 2014;198:438–447. doi: 10.1016/j.snb.2014.03.049. [DOI] [Google Scholar]
- Yuan M. Liu A. Zhao M. Dong W. Zhao T. Wang J. Tang W. Bimetallic PdCu Nanoparticle Decorated Three-Dimensional Graphene Hydrogel for Non-Enzymatic Amperometric Glucose Sensor. Sens. Actuators, B. 2014;190:707–714. doi: 10.1016/j.snb.2013.09.054. [DOI] [Google Scholar]
- Ismail N. S. Le Q. H. Yoshikawa H. Saito M. Tamiya E. Development of Non-enzymatic Electrochemical Glucose Sensor Based on Graphene Oxide Nanoribbon–Gold Nanoparticle Hybrid. Electrochim. Acta. 2014;146:98–105. doi: 10.1016/j.electacta.2014.08.123. [DOI] [Google Scholar]
- Gao W. Tjiu W. W. Wei J. Liu T. Highly Sensitive Nonenzymatic Glucose and H2O2 Sensor Based on Ni(OH)2/Electroreduced Graphene Oxide−Multiwalled Carbon Nanotube Film Modified Glass Carbon Electrode. Talanta. 2014;120:484–490. doi: 10.1016/j.talanta.2013.12.012. [DOI] [PubMed] [Google Scholar]
- Ye Y. Wang P. Dai E. Liu J. Tian Z. Liang C. Shao G. A Novel Reduction Approach to Fabricate Quantum-Sized SnO2-Conjugated Reduced Graphene Oxide Nanocomposites as Non-Enzymatic Glucose Sensors. Phys. Chem. Chem. Phys. 2014;16:8801–8807. doi: 10.1039/C4CP00554F. [DOI] [PubMed] [Google Scholar]
- Liu Z. Guo Y. Dong C. A High Performance Nonenzymatic Electrochemical Glucose Sensor Based on Polyvinylpyrrolidone–Graphene Nanosheets–Nickel Nanoparticles–Chitosan Nanocomposite. Talanta. 2015;137:87–93. doi: 10.1016/j.talanta.2015.01.037. [DOI] [PubMed] [Google Scholar]
- Dhara K. Ramachandran T. Nair B. G. Satheesh Babu T. G. Single Step Synthesis of Au–CuO Nanoparticles Decorated Reduced Graphene Oxide for High Performance Disposable Nonenzymatic Glucose Sensor. J. Electroanal. Chem. 2015;743:1–9. doi: 10.1016/j.jelechem.2015.02.005. [DOI] [Google Scholar]
- Fu S. Fan G. Yang L. Li F. Non-Enzymatic Glucose Sensor Based on Au Nanoparticles Decorated Ternary Ni-Al Layered Double Hydroxide/Single-Walled Carbon Nanotubes/Graphene Nanocomposite. Electrochim. Acta. 2015;152:146–154. doi: 10.1016/j.electacta.2014.11.115. [DOI] [Google Scholar]
- Tian Y. Liu Y. Wang W.-p. Zhang X. Peng W. CuO Nanoparticles on Sulfur-Doped Graphene for Nonenzymatic Glucose Sensing. Electrochim. Acta. 2015;156:244–251. doi: 10.1016/j.electacta.2015.01.016. [DOI] [Google Scholar]
- Yang S. Liu L. Wang G. Li G. Deng D. Qu L. One-Pot Synthesis of Mn3O4 Nanoparticles Decorated with Nitrogen-Doped Reduced Graphene Oxide for Sensitive Nonenzymatic Glucose Sensing. J. Electroanal. Chem. 2015;755:15–21. doi: 10.1016/j.jelechem.2015.07.021. [DOI] [Google Scholar]
- Zhang X. Liao Q. Liu S. Xu W. Liu Y. Zhang Y. CuNiO Nanoparticles Assembled on Graphene as an Effective Platform for Enzyme-Free Glucose Sensing. Anal. Chim. Acta. 2015;858:49–54. doi: 10.1016/j.aca.2014.12.007. [DOI] [PubMed] [Google Scholar]
- Chang G. Shu H. Huang Q. Oyama M. Ji K. Liu X. He Y. Synthesis of Highly Dispersed Pt Nanoclusters Anchored Graphene Composites and Their Application for Non-Enzymatic Glucose Sensing. Electrochim. Acta. 2015;157:149–157. doi: 10.1016/j.electacta.2015.01.085. [DOI] [Google Scholar]
- Wang Q. Wang Q. Li M. Szunerits S. Boukherroub R. Preparation of Reduced Graphene Oxide/Cu Nanoparticle Composites Through Electrophoretic Deposition: Application for Nonenzymatic Glucose Sensing. RSC Adv. 2015;5:15861–15869. doi: 10.1039/C4RA14132F. [DOI] [Google Scholar]
- Wang L. Lu X. Wen C. Xie Y. Miao L. Chen S. Li H. Li P. Song Y. One-Step Synthesis of Pt–NiO Nanoplate Array/Reduced Graphene Oxide Nanocomposites for Nonenzymatic Glucose Sensing. J. Mater. Chem. A. 2015;3:608–616. doi: 10.1039/C4TA04724A. [DOI] [Google Scholar]
- Wu M. Meng S. Wang Q. Si W. Huang W. Dong X. Nickel–Cobalt Oxide Decorated Three-Dimensional Graphene as an Enzyme Mimic for Glucose and Calcium Detection. ACS Appl. Mater. Interfaces. 2015;7:21089–21094. doi: 10.1021/acsami.5b06299. [DOI] [PubMed] [Google Scholar]
- Zhuang X. Tian C. Luan F. Wu X. Chen L. One-Step Electrochemical Fabrication of a Nickel Oxide Nanoparticle/Polyaniline Nanowire/Graphene Oxide Hybrid on a Glassy Carbon Electrode for use as a Non-Enzymatic Glucose Biosensor. RSC Adv. 2016;6:92541–92546. doi: 10.1039/C6RA14970G. [DOI] [Google Scholar]
- Yang Z. Yan X. Li Z. Zheng X. Zheng J. Synthesis of Cu2O on AlOOH/Reduced Graphene Oxide for Non-Enzymatic Amperometric Glucose Sensing. Anal. Methods. 2016;8:1527–1531. doi: 10.1039/C5AY03258J. [DOI] [Google Scholar]
- Ma G. Yang M. Li C. Tan H. Deng L. Xie S. Xu F. Wang L. Song Y. Preparation of Spinel Nickel-Cobalt Oxide Nanowrinkles/Reduced Graphene Oxide Hybrid for Nonenzymatic Glucose Detection at Physiological Level. Electrochim. Acta. 2016;220:545–553. doi: 10.1016/j.electacta.2016.10.163. [DOI] [Google Scholar]
- Pourbeyram S. Mehdizadeh K. Nonenzymatic Glucose Sensor Based on Disposable Pencil Graphite Electrode Modified by Copper Nanoparticles. J. Food Drug Anal. 2016;24:894–902. doi: 10.1016/j.jfda.2016.02.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu S. Hui K. S. Hui K. N. Flower-Like Copper Cobaltite Nanosheets on Graphite Paper as High-Performance Supercapacitor Electrodes and Enzymeless Glucose Sensors. ACS Appl. Mater. Interfaces. 2016;8:3258–3267. doi: 10.1021/acsami.5b11001. [DOI] [PubMed] [Google Scholar]
- Wang C. Sun Y. Yu X. Ma D. Zheng J. Dou P. Cao Z. Xu X. Ag–Pt Hollow Nanoparticles Anchored Reduced Graphene Oxide Composites for Non-Enzymatic Glucose Biosensor. J. Mater. Sci.: Mater. Electron. 2016;27:9370–9378. doi: 10.1007/s10854-016-4979-2. [DOI] [Google Scholar]
- Yang J. Ye H. Zhang Z. Zhao F. Zeng B. Metal–Organic Framework Derived Hollow Polyhedron CuCo2O4 Functionalized Porous Graphene for Sensitive Glucose Sensing. Sens. Actuators, B. 2017;242:728–735. doi: 10.1016/j.snb.2016.11.122. [DOI] [Google Scholar]
- Samuei S. Fakkar J. Rezvani Z. Shomali A. Habibi B. Synthesis and Characterization of Graphene Quantum Dots/CoNiAl-Layered Double-Hydroxide Nanocomposite: Application as a Glucose Sensor. Anal. Biochem. 2017;521:31–39. doi: 10.1016/j.ab.2017.01.005. [DOI] [PubMed] [Google Scholar]
- Gopalan A. I. Muthuchamy N. Lee K. P. A Novel Bismuth Oxychloride-Graphene Hybrid Nanosheets Based Non-Enzymatic Photoelectrochemical Glucose Sensing Platform for High Performances. Biosens. Bioelectron. 2017;89:352–360. doi: 10.1016/j.bios.2016.07.017. [DOI] [PubMed] [Google Scholar]
- Thanh T. D. Balamurugan J. Lee S. H. Kim N. H. Lee J. H. Effective Seed-Assisted Synthesis of Gold Nanoparticles Anchored Nitrogen-Doped Graphene for Electrochemical Detection of Glucose and Dopamine. Biosens. Bioelectron. 2016;81:259–267. doi: 10.1016/j.bios.2016.02.070. [DOI] [PubMed] [Google Scholar]
- Karikalan N. Karthik R. Chen S.-M. Karuppiah C. Elangovan A. Sonochemical Synthesis of Sulfur Doped Reduced Graphene Oxide Supported CuS Nanoparticles for the Non-Enzymatic Glucose Sensor Applications. Sci. Rep. 2017;7:2494. doi: 10.1038/s41598-017-02479-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rao H. Zhang Z. Ge H. Liu X. Zou P. Wang X. Wang Y. Enhanced Amperometric Sensing Using a NiCo2O4/Nitrogen-Doped Reduced Graphene Oxide/Ionic Liquid Ternary Composite for Enzyme-Free Detection of Glucose. New J. Chem. 2017;41:3667–3676. doi: 10.1039/C7NJ00077D. [DOI] [Google Scholar]
- Balasubramanian P. Velmurugan M. Chen S.-M. Hwa K.-Y. Optimized Electrochemical Synthesis of Copper Nanoparticles Decorated Reduced Graphene Oxide: Application for Enzymeless Determination of Glucose in Human Blood. J. Electroanal. Chem. 2017;807:128–136. doi: 10.1016/j.jelechem.2017.11.042. [DOI] [Google Scholar]
- Hui N. Wang J. Electrodeposited Honeycomb-Like Cobalt Nanostructures on Graphene Oxide Doped Polypyrrole Nanocomposite for High Performance Enzymeless Glucose Sensing. J. Electroanal. Chem. 2017;798:9–16. doi: 10.1016/j.jelechem.2017.05.021. [DOI] [Google Scholar]
- Mazaheri M. Aashuri H. Simchi A. Three-Dimensional Hybrid Graphene/Nickel Electrodes on Zinc Oxide Nanorod Arrays as Non-Enzymatic Glucose Biosensors. Sens. Actuators, B. 2017;251:462–471. doi: 10.1016/j.snb.2017.05.062. [DOI] [Google Scholar]
- Yang S. Li G. Wang D. Qiao Z. Qu L. Synthesis of Nanoneedle-Like Copper Oxide on N-Doped Reduced Graphene Oxide: A Three-Dimensional Hybrid for Nonenzymatic Glucose Sensor. Sens. Actuators, B. 2017;238:588–595. doi: 10.1016/j.snb.2016.07.105. [DOI] [Google Scholar]
- Wu H. Yu Y. Gao W. Gao A. Qasim A. M. Zhang F. Wang J. Ding K. Wu G. Chu P. K. Nickel Plasma Modification of Graphene for High-Performance Non-Enzymatic Glucose Sensing. Sens. Actuators, B. 2017;251:842–850. doi: 10.1016/j.snb.2017.05.128. [DOI] [Google Scholar]
- Yan X. Gu Y. Li C. Zheng B. Li Y. Zhang T. Zhang Z. Yang M. A Non-Enzymatic Glucose Sensor Based on the CuS Nanoflakes–Reduced Graphene Oxide Nanocomposite. Anal. Methods. 2018;10:381–388. doi: 10.1039/C7AY02290E. [DOI] [Google Scholar]
- Babu K. J. Sheet S. Lee Y. S. Kumar G. G. Three-Dimensional Dendrite Cu–Co/Reduced Graphene Oxide Architectures on a Disposable Pencil Graphite Electrode as an Electrochemical Sensor for Nonenzymatic Glucose Detection. ACS Sustainable Chem. Eng. 2018;6:1909–1918. doi: 10.1021/acssuschemeng.7b03314. [DOI] [Google Scholar]
- Jothi L. Jayakumar N. Jaganathan S. K. Nageswaran G. Ultrasensitive and Selective Non-Enzymatic Electrochemical Glucose Sensor Based on Hybrid Material of Graphene Nanosheets/Graphene Nanoribbons/Nickel Nanoparticle. Mater. Res. Bull. 2018;98:300–307. doi: 10.1016/j.materresbull.2017.10.020. [DOI] [Google Scholar]
- Zhang Q. Luo Q. Qin Z. Liu L. Wu Z. Shen B. Hu W. Self-Assembly of Graphene-Encapsulated Cu Composites for Nonenzymatic Glucose Sensing. ACS Omega. 2018;3:3420–3428. doi: 10.1021/acsomega.7b01197. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li M. Bo X. Mu Z. Zhang Y. Guo L. Electrodeposition of Nickel Oxide and Platinum Nanoparticles on Electrochemically Reduced Graphene Oxide Film as a Nonenzymatic Glucose Sensor. Sens. Actuators, B. 2014;192:261–268. doi: 10.1016/j.snb.2013.10.140. [DOI] [Google Scholar]
- Hoa L. T. Chung J. S. Hur S. H. A Highly Sensitive Enzyme-Free Glucose Sensor Based on Co3O4 Nanoflowers and 3D Graphene Oxide Hydrogel Fabricated via Hydrothermal Synthesis. Sens. Actuators, B. 2016;223:76–82. doi: 10.1016/j.snb.2015.09.009. [DOI] [Google Scholar]
- Ahmadalinezhad A. Chen A. High-Performance Electrochemical Biosensor for the Detection of Total Cholesterol. Biosens. Bioelectron. 2011;26:4508–4513. doi: 10.1016/j.bios.2011.05.011. [DOI] [PubMed] [Google Scholar]
- Sekretaryova A. N. Beni V. Eriksson M. Karyakin A. A. Turner A. P. F. Vagin M. Y. Cholesterol Self-Powered Biosensor. Anal. Chem. 2014;86:9540–9547. doi: 10.1021/ac501699p. [DOI] [PubMed] [Google Scholar]
- Dey R. S. Raj C. R. Redox-Functionalized Graphene Oxide Architecture for the Development of Amperometric Biosensing Platform. ACS Appl. Mater. Interfaces. 2013;5:4791–4798. doi: 10.1021/am400280u. [DOI] [PubMed] [Google Scholar]
- Lee Y.-J. Park J.-Y. Nonenzymatic Free-Cholesterol Detection via a Modified Highly Sensitive Macroporous Gold Electrode with Platinum Nanoparticles. Biosens. Bioelectron. 2010;26:1353–1358. doi: 10.1016/j.bios.2010.07.048. [DOI] [PubMed] [Google Scholar]
- Saxena U. Das A. B. Nanomaterials Towards Fabrication of Cholesterol Biosensors: Key Roles and Design Approaches. Biosens. Bioelectron. 2016;75:196–205. doi: 10.1016/j.bios.2015.08.042. [DOI] [PubMed] [Google Scholar]
- Dey R. S. Raj C. R. Development of an Amperometric Cholesterol Biosensor Based on Graphene−Pt Nanoparticle Hybrid Material. J. Phys. Chem. C. 2010;114:21427–21433. doi: 10.1021/jp105895a. [DOI] [Google Scholar]
- Manjunatha R. Shivappa Suresh G. Savio Melo J. D'Souza S. F. Venkatarangaiah Venkatesha T. An Amperometric Bienzymatic Cholesterol Biosensor Based on Functionalized Graphene Modified Electrode and its Electrocatalytic Activity Towards Total Cholesterol Determination. Talanta. 2012;99:302–309. doi: 10.1016/j.talanta.2012.05.056. [DOI] [PubMed] [Google Scholar]
- Zhang M. Yuan R. Chai Y. Chen S. Zhong X. Zhong H. Wang C. A Cathodic Electrogenerated Chemiluminescence Biosensor Based on Luminol and Hemin-Graphene Nanosheets for Cholesterol Detection. RSC Adv. 2012;2:4639–4641. doi: 10.1039/C2RA20374J. [DOI] [Google Scholar]
- Zhang M. Yuan R. Chai Y. Wang C. Wu X. Cerium Oxide–Graphene as the Matrix for Cholesterol Sensor. Anal. Biochem. 2013;436:69–74. doi: 10.1016/j.ab.2013.01.022. [DOI] [PubMed] [Google Scholar]
- Cao S. Zhang L. Chai Y. Yuan R. An Integrated Sensing System for Detection of Cholesterol Based on TiO2–Graphene–Pt–Pd Hybrid Nanocomposites. Biosens. Bioelectron. 2013;42:532–538. doi: 10.1016/j.bios.2012.10.048. [DOI] [PubMed] [Google Scholar]
- Cao S. Zhang L. Chai Y. Yuan R. Electrochemistry of Cholesterol Biosensor Based on a Novel Pt–Pd Bimetallic Nanoparticle Decorated Graphene Catalyst. Talanta. 2013;109:167–172. doi: 10.1016/j.talanta.2013.02.002. [DOI] [PubMed] [Google Scholar]
- Wu X. Chai Y. Yuan R. Zhong X. Zhang J. Synthesis of Multiwall Carbon Nanotubes-Graphene Oxide-Thionine-Au Nanocomposites for Electrochemiluminescence Detection of Cholesterol. Electrochim. Acta. 2014;129:441–449. doi: 10.1016/j.electacta.2014.02.103. [DOI] [Google Scholar]
- Ruecha N. Rangkupan R. Rodthongkum N. Chailapakul O. Novel Paper-Based Cholesterol Biosensor Using Graphene/Polyvinylpyrrolidone/Polyaniline Nanocomposite. Biosens. Bioelectron. 2014;52:13–19. doi: 10.1016/j.bios.2013.08.018. [DOI] [PubMed] [Google Scholar]
- Parlak O. Tiwari A. Turner A. P. F. Tiwari A. Template-Directed Hierarchical Self-Assembly of Graphene Based Hybrid Structure for Electrochemical Biosensing. Biosens. Bioelectron. 2013;49:53–62. doi: 10.1016/j.bios.2013.04.004. [DOI] [PubMed] [Google Scholar]
- Dey R. S. Raj C. R. Enzyme-integrated cholesterol biosensing scaffold based on in situ synthesized reduced graphene oxide and dendritic Pd nanostructure. Biosens. Bioelectron. 2014;62:357–364. doi: 10.1016/j.bios.2014.06.063. [DOI] [PubMed] [Google Scholar]
- Gholivand M. B. Khodadadian M. Amperometric Cholesterol Biosensor Based on the Direct Electrochemistry of Cholesterol Oxidase and Catalase on a Graphene/Ionic Liquid-Modified Glassy Carbon Electrode. Biosens. Bioelectron. 2014;53:472–478. doi: 10.1016/j.bios.2013.09.074. [DOI] [PubMed] [Google Scholar]
- Li Z. Xie C. Wang J. Meng A. Zhang F. Direct Electrochemistry of Cholesterol Oxidase Immobilized on Chitosan–Graphene and Cholesterol Sensing. Sens. Actuators, B. 2015;208:505–511. doi: 10.1016/j.snb.2014.11.054. [DOI] [Google Scholar]
- Wu Q. Hou Y. Zhang M. Hou X. Xu L. Wang N. Wang J. Huang W. Amperometric Cholesterol Biosensor Based on Zinc Oxide Films on a Silver Nanowire–Graphene Oxide Modified Electrode. Anal. Methods. 2016;8:1806–1812. doi: 10.1039/C6AY00158K. [DOI] [Google Scholar]
- Yang L. Zhao H. Li Y. Ran X. Deng G. Zhang Y. Ye H. Zhao G. Li C.-P. Indicator Displacement Assay for Cholesterol Electrochemical Sensing Using a Calix[6]arene Functionalized Graphene-Modified Electrode. Analyst. 2016;141:270–278. doi: 10.1039/C5AN01843A. [DOI] [PubMed] [Google Scholar]
- Xu L. Hou Y. Zhang M. Cheng T. Huang W. Yao C. Wu Q. Electrochemical Sensor Based on a Silver Nanowires Modified Electrode for the Determination of Cholesterol. Anal. Methods. 2015;7:5649–5653. doi: 10.1039/C5AY01164G. [DOI] [Google Scholar]
- Huan J. Liu Q. Fei A. Qian J. Dong X. Qiu B. Mao H. Wang K. Amplified Solid-State Electrochemiluminescence Detection of Cholesterol in Near-Infrared Range Based on CDTE Quantum Dots Decorated Multiwalled Carbon Nanotubes@Reduced Graphene Oxide Nanoribbons. Biosens. Bioelectron. 2015;73:221–227. doi: 10.1016/j.bios.2015.06.004. [DOI] [PubMed] [Google Scholar]
- Abraham S. Srivastava S. Kumar V. Pandey S. Rastogi P. K. Nirala N. R. Kashyap S. Srivastava S. K. Singh V. N. Ganesan V. Saxena P. S. Srivastava A. Enhanced Electrochemical Biosensing Efficiency of Silica Particles Supported on Partially Reduced Graphene Oxide for Sensitive Detection of Cholesterol. J. Electroanal. Chem. 2015;757:65–72. doi: 10.1016/j.jelechem.2015.09.016. [DOI] [Google Scholar]
- Rengaraj A. Haldorai Y. Kwak C. H. Ahn S. Jeon K.-J. Park S. H. Han Y.-K. Huh Y. S. Electrodeposition of Flower-Like Nickel Oxide on CVD-Grown Graphene to Develop an Electrochemical Non-Enzymatic Biosensor. J. Mater. Chem. B. 2015;3:6301–6309. doi: 10.1039/C5TB00908A. [DOI] [PubMed] [Google Scholar]
- Wu S. Wang Y. Mao H. Wang C. Xia L. Zhang Y. Ge H. Song X.-M. Direct Electrochemistry of Cholesterol Oxidase and Biosensing of Cholesterol Based on PSS/Polymeric Ionic Liquid–Graphene Nanocomposite. RSC Adv. 2016;6:59487–59496. doi: 10.1039/C6RA06073K. [DOI] [Google Scholar]
- Pramanik K. Sarkar P. Bhattacharyay D. Majumdar P. One Step Electrode Fabrication for Direct Electron Transfer Cholesterol Biosensor Based on Composite of Polypyrrole, Green Reduced Graphene Oxide and Cholesterol Oxidase. Electroanalysis. 2018;30:2719–2730. doi: 10.1002/elan.201800318. [DOI] [Google Scholar]
- Komathi S. Muthuchamy N. Lee K. P. Gopalan A. I. Fabrication of a Novel Dual Mode Cholesterol Biosensor Using Titanium Dioxide Nanowire Bridged 3D Graphene Nanostacks. Biosens. Bioelectron. 2016;84:64–71. doi: 10.1016/j.bios.2015.11.042. [DOI] [PubMed] [Google Scholar]
- Du X. Jiang D. Chen S. Dai L. Zhou L. Hao N. You T. Mao H. Wang K. CeO2 Nanocrystallines Ensemble-on-Nitrogen-Doped Graphene Nanocomposites: One-Pot, Rapid Synthesis and Excellent Electrocatalytic Activity for Enzymatic Biosensing. Biosens. Bioelectron. 2017;89:681–688. doi: 10.1016/j.bios.2015.11.054. [DOI] [PubMed] [Google Scholar]
- Huang Y. Tan J. Cui L. Zhou Z. Zhou S. Zhang Z. Zheng R. Xue Y. Zhang M. Li S. Zhu N. Liang J. Li G. Zhong L. Zhao Y. Graphene and Au NPs co-Mediated Enzymatic Silver Deposition for the Ultrasensitive Electrochemical Detection of Cholesterol. Biosens. Bioelectron. 2018;102:560–567. doi: 10.1016/j.bios.2017.11.037. [DOI] [PubMed] [Google Scholar]
- Karimi S. Ghourchian H. Rahimi P. Rafiee-Pour H.-A. A Nanocomposite Based Biosensor for Cholesterol Determination. Anal. Methods. 2012;4:3225–3231. doi: 10.1039/C2AY25826A. [DOI] [Google Scholar]
- Agnihotri N. Chowdhury A. D. De A. Non-Enzymatic Electrochemical Detection of Cholesterol Using β-Cyclodextrin Functionalized Graphene. Biosens. Bioelectron. 2015;63:212–217. doi: 10.1016/j.bios.2014.07.037. [DOI] [PubMed] [Google Scholar]
- Lakshmi G. B. V. S. Sharma A. Solanki P. R. Avasthi D. K. Mesoporous Polyaniline Nanofiber Decorated Graphene Micro-Flowers for Enzyme-Less Cholesterol Biosensors. Nanotechnology. 2016;27:345101. doi: 10.1088/0957-4484/27/34/345101. [DOI] [PubMed] [Google Scholar]
- Alexander S. Baraneedharan P. Balasubrahmanyan S. Ramaprabhu S. Modified Graphene Based Molecular Imprinted Polymer for Electrochemical Non-Enzymatic Cholesterol Biosensor. Eur. Polym. J. 2017;86:106–116. doi: 10.1016/j.eurpolymj.2016.11.024. [DOI] [Google Scholar]
- Chen W. Cai S. Ren Q.-Q. Wen W. Zhao Y.-D. Recent Advances in Electrochemical Sensing for Hydrogen Peroxide: A Review. Analyst. 2012;137:49–58. doi: 10.1039/C1AN15738H. [DOI] [PubMed] [Google Scholar]
- Hou B. Liu H. Qi S. Zhu Y. Zhou B. Jiang X. Zhu L. Preparation of Pristine Graphene in Ethanol Assisted by Organic Salts for Nonenzymatic Detection of Hydrogen Peroxide. J. Colloid Interface Sci. 2018;510:103–110. doi: 10.1016/j.jcis.2017.09.052. [DOI] [PubMed] [Google Scholar]
- Yu Z. Zou L. Chen Y. Jiang J. (Pc)Eu(Pc)Eu[trans-T(COOCH3)2PP]/GO Hybrid Film-Based Nonenzymatic H2O2 Electrochemical Sensor with Excellent Performance. ACS Appl. Mater. Interfaces. 2016;8:30398–30406. doi: 10.1021/acsami.6b08760. [DOI] [PubMed] [Google Scholar]
- Mohammad-Rezaei R. Razmi H. Reduced Graphene Oxide|Carbon Ceramic Electrode Modified with CdS-Hemoglobin as a Sensitive Hydrogen Peroxide Biosensor. Electroanalysis. 2012;24:2094–2101. doi: 10.1002/elan.201200286. [DOI] [Google Scholar]
- Sun W. Ju X. Zhang Y. Sun X. Li G. Sun Z. Application of Carboxyl Functionalized Graphene Oxide as Mimetic Peroxidase for Sensitive Voltammetric Detection of H2O2 with 3,3′,5,5′-Tetramethylbenzidine. Electrochem. Commun. 2013;26:113–116. doi: 10.1016/j.elecom.2012.09.032. [DOI] [Google Scholar]
- Jha S. K. Kumar C. N. Raj R. P. Jha N. S. Mohan S. Synthesis of 3D Porous CeO2/Reduced Graphene Oxide Xerogel Composite and Low Level Detection of H2O2. Electrochim. Acta. 2014;120:308–313. doi: 10.1016/j.electacta.2013.12.051. [DOI] [Google Scholar]
- Xu F. Sun Y. Zhang Y. Shi Y. Wen Z. Li Z. Graphene–Pt Nanocomposite for Nonenzymatic Detection of Hydrogen Peroxide with Enhanced Sensitivity. Electrochem. Commun. 2011;13:1131–1134. doi: 10.1016/j.elecom.2011.07.017. [DOI] [Google Scholar]
- Dong X. Ma Y. Zhu G. Huang Y. Wang J. Chan-Park M. B. Wang L. Huang W. Chen P. Synthesis of Graphene–Carbon Nanotube Hybrid Foam and its use as a Novel Three-Dimensional Electrode for Electrochemical Sensing. J. Mater. Chem. 2012;22:17044–17048. doi: 10.1039/C2JM33286H. [DOI] [Google Scholar]
- Xiao F. Li Y. Zan X. Liao K. Xu R. Duan H. Growth of Metal-Metal Oxide Nanostructures on Freestanding Graphene Paper for Flexible Biosensors. Adv. Funct. Mater. 2012;22:2487–2494. doi: 10.1002/adfm.201200191. [DOI] [Google Scholar]
- Xiao F. Song J. Gao H. Zan X. Xu R. Duan H. Coating Graphene Paper with 2D-Assembly of Electrocatalytic Nanoparticles: A Modular Approach toward High-Performance Flexible Electrodes. ACS Nano. 2012;6:100–110. doi: 10.1021/nn202930m. [DOI] [PubMed] [Google Scholar]
- Yang J.-H. Myoung N. Hong H.-G. Facile and Controllable Synthesis of Prussian Blue on Chitosan-Functionalized Graphene Nanosheets for the Electrochemical Detection of Hydrogen Peroxide. Electrochim. Acta. 2012;81:37–43. doi: 10.1016/j.electacta.2012.07.038. [DOI] [Google Scholar]
- Zhong L. Gan S. Fu X. Li F. Han D. Guo L. Niu L. Electrochemically Controlled Growth of Silver Nanocrystals on Graphene Thin Film and Applications for Efficient Nonenzymatic H2O2 Biosensor. Electrochim. Acta. 2013;89:222–228. doi: 10.1016/j.electacta.2012.10.161. [DOI] [Google Scholar]
- Zhu N. Han S. Gan S. Ulstrup J. Chi Q. Graphene Paper Doped with Chemically Compatible Prussian Blue Nanoparticles as Nanohybrid Electrocatalyst. Adv. Funct. Mater. 2013;23:5297–5306. doi: 10.1002/adfm.201300605. [DOI] [Google Scholar]
- Zhang P. Zhang X. Zhang S. Lu X. Li Q. Su Z. Wei G. One-Pot Green Synthesis, Characterizations, and Biosensor Application of Self-Assembled Reduced Graphene Oxide–Gold Nanoparticle Hybrid Membranes. J. Mater. Chem. B. 2013;1:6525–6531. doi: 10.1039/C3TB21270J. [DOI] [PubMed] [Google Scholar]
- Teymourian H. Salimi A. Firoozi S. Korani A. Soltanian S. One-Pot Hydrothermal Synthesis of Zirconium Dioxide Nanoparticles Decorated Reduced Graphene Oxide Composite as High Performance Electrochemical Sensing and Biosensing Platform. Electrochim. Acta. 2014;143:196–206. doi: 10.1016/j.electacta.2014.08.007. [DOI] [Google Scholar]
- Wang Q. Li M. Szunerits S. Boukherroub R. Environmentally Friendly Reduction of Graphene Oxide Using Tyrosine for Nonenzymatic Amperometric H2O2 Detection. Electroanalysis. 2014;26:156–163. doi: 10.1002/elan.201300356. [DOI] [Google Scholar]
- Maji S. K. Sreejith S. Mandal A. K. Ma X. Zhao Y. Immobilizing Gold Nanoparticles in Mesoporous Silica Covered Reduced Graphene Oxide: A Hybrid Material for Cancer Cell Detection through Hydrogen Peroxide Sensing. ACS Appl. Mater. Interfaces. 2014;6:13648–13656. doi: 10.1021/am503110s. [DOI] [PubMed] [Google Scholar]
- Mahmoudian M. R. Alias Y. Basirun W. J. Woi P. M. Sookhakian M. Facile Preparation of MnO2 Nanotubes/Reduced Graphene Oxide Nanocomposite for Electrochemical Sensing of Hydrogen Peroxide. Sens. Actuators, B. 2014;201:526–534. doi: 10.1016/j.snb.2014.05.030. [DOI] [Google Scholar]
- Wu B. Zhao N. Hou S. Zhang C. Electrochemical Synthesis of Polypyrrole, Reduced Graphene Oxide, and Gold Nanoparticles Composite and its Application to Hydrogen Peroxide Biosensor. Nanomaterials. 2016;6:220. doi: 10.3390/nano6110220. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sun Y. He K. Zhang Z. Zhou A. Duan H. Real-Time Electrochemical Detection of Hydrogen Peroxide Secretion in Live Cells by Pt Nanoparticles Decorated Graphene–Carbon Nanotube Hybrid Paper Electrode. Biosens. Bioelectron. 2015;68:358–364. doi: 10.1016/j.bios.2015.01.017. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Wang Z. Ji Y. Liu S. Zhang T. Synthesis of Ag Nanoparticle–Carbon Nanotube–Reduced Graphene Oxide Hybrids for Highly Sensitive Non-Enzymatic Hydrogen Peroxide Detection. RSC Adv. 2015;5:39037–39041. doi: 10.1039/C5RA04246A. [DOI] [Google Scholar]
- Liu J. Bo X. Zhao Z. Guo L. Highly Exposed Pt Nanoparticles Supported on Porous Graphene for Electrochemical Detection of Hydrogen Peroxide in Living Cells. Biosens. Bioelectron. 2015;74:71–77. doi: 10.1016/j.bios.2015.06.042. [DOI] [PubMed] [Google Scholar]
- Zhang M. Halder A. Hou C. Ulstrup J. Chi Q. Free-Standing and Flexible Graphene Papers as Disposable Non-Enzymatic Electrochemical Sensors. Bioelectrochemistry. 2016;109:87–94. doi: 10.1016/j.bioelechem.2016.02.002. [DOI] [PubMed] [Google Scholar]
- Liu H. Guo K. Duan C. Dong X. Gao J. Hollow TiO2 Modified Reduced Graphene Oxide Microspheres Encapsulating Hemoglobin for a Mediator-Free Biosensor. Biosens. Bioelectron. 2017;87:473–479. doi: 10.1016/j.bios.2016.08.089. [DOI] [PubMed] [Google Scholar]
- Sharma V. Mobin S. M. Cytocompatible Peroxidase Mimic CuO:Graphene Nanosphere Composite as Colorimetric Dual Sensor for Hydrogen Peroxide and Cholesterol With its Logic Gate Implementation. Sens. Actuators, B. 2017;240:338–348. doi: 10.1016/j.snb.2016.08.169. [DOI] [Google Scholar]
- Zhao Y. Huo D. Bao J. Yang M. Chen M. Hou J. Fa H. Hou C. Biosensor Based on 3D Graphene-Supported Fe3O4 Quantum Dots as Biomimetic Enzyme for In situ Detection of H2O2 Released from Living Cells. Sens. Actuators, B. 2017;244:1037–1044. doi: 10.1016/j.snb.2017.01.029. [DOI] [Google Scholar]
- Dinesh B. Mani V. Saraswathi R. Chen S.-M. Direct electrochemistry of cytochrome c immobilized on a graphene oxide–carbon nanotube composite for picomolar detection of hydrogen peroxide. RSC Adv. 2014;4:28229–28237. doi: 10.1039/C4RA02789B. [DOI] [Google Scholar]
- Zor E. Saglam M. E. Akin I. Saf A. O. Bingol H. Ersoz M. Green Synthesis of Reduced Graphene Oxide/Nanopolypyrrole Composite: Characterization and H2O2 Determination in Urine. RSC Adv. 2014;4:12457–12466. doi: 10.1039/C4RA00578C. [DOI] [Google Scholar]
- Sadhukhan M. Bhowmik T. Kundu M. K. Barman S. Facile Synthesis of Carbon Quantum Dots and Thin Graphene Sheets for Non-Enzymatic Sensing of Hydrogen Peroxide. RSC Adv. 2014;4:4998–5005. doi: 10.1039/C3RA46050A. [DOI] [Google Scholar]
- Vilian A. T. E. Chen S.-M. Simple Approach for the Immobilization of Horseradish Peroxidase on Poly-L-Histidine Modified Reduced Graphene Oxide for Amperometric Determination of Dopamine and H2O2. RSC Adv. 2014;4:55867–55876. doi: 10.1039/C4RA09011J. [DOI] [Google Scholar]
- Lei W. Wu L. Huang W. Hao Q. Zhang Y. Xia X. Microwave-Assisted Synthesis of Hemin–Graphene/Poly(3,4-Ethylenedioxythiophene) Nanocomposite for a Biomimetic Hydrogen Peroxide Biosensor. J. Mater. Chem. B. 2014;2:4324–4330. doi: 10.1039/C4TB00313F. [DOI] [PubMed] [Google Scholar]
- Zhang M. Wang Z. Nanostructured Silver Nanowires-Graphene Hybrids for Enhanced Electrochemical Detection of Hydrogen Peroxide. Appl. Phys. Lett. 2013;102:213104. doi: 10.1063/1.4807921. [DOI] [Google Scholar]
- Shang L. Zeng B. Zhao F. Fabrication of Novel Nitrogen-Doped Graphene–Hollow AuPd Nanoparticle Hybrid Films for the Highly Efficient Electrocatalytic Reduction of H2O2. ACS Appl. Mater. Interfaces. 2015;7:122–128. doi: 10.1021/am507149y. [DOI] [PubMed] [Google Scholar]
- Li S. Xiong J. Shen J. Qin Y. Li J. Chu F. Kong Y. Deng L. A Novel Hydrogen Peroxide Sensor Based on Ag Nanoparticles Decorated Polyaniline/Graphene Composites. J. Appl. Polym. Sci. 2015;132:4–9. [Google Scholar]
- Radhakrishnan S. Kim S. J. An Enzymatic Biosensor for Hydrogen Peroxide Based on One-Pot Preparation of CeO2-Reduced Graphene Oxide Nanocomposite. RSC Adv. 2015;5:12937–12943. doi: 10.1039/C4RA12841A. [DOI] [Google Scholar]
- Karuppiah C. Palanisamy S. Chen S.-M. Veeramani V. Periakaruppan P. A Novel Enzymatic Glucose Biosensor and Sensitive Non-Enzymatic Hydrogen Peroxide Sensor Based on Graphene and Cobalt Oxide Nanoparticles Composite Modified Glassy Carbon Electrode. Sens. Actuators, B. 2014;196:450–456. doi: 10.1016/j.snb.2014.02.034. [DOI] [Google Scholar]
- Yang Z. Qi C. Zheng X. Zheng J. Facile Synthesis of Silver Nanoparticle-Decorated Graphene Oxide Nanocomposites and their Application for Electrochemical Sensing. New J. Chem. 2015;39:9358–9362. doi: 10.1039/C5NJ01621E. [DOI] [Google Scholar]
- Palanisamy S. Lee H. F. Chen S.-M. Thirumalraj B. An Electrochemical Facile Fabrication of Platinum Nanoparticle Decorated Reduced Graphene Oxide; Application for Enhanced Electrochemical Sensing of H2O2. RSC Adv. 2015;5:105567–105573. doi: 10.1039/C5RA20512C. [DOI] [Google Scholar]
- Wang J. Zhu H. Xu Y. Yang W. Liu A. Shan F. Cao M. Liu J. Graphene Nanodots Encaged 3-D Gold Substrate as Enzyme Loading Platform for The Fabrication of High Performance Biosensors. Sens. Actuators, B. 2015;220:1186–1195. doi: 10.1016/j.snb.2015.06.044. [DOI] [Google Scholar]
- Liu J. Zhang M. Liu J. Zheng J. Synthesis of Ag@Pt Core–Shell Nanoparticles Loaded onto Reduced Graphene Oxide and Investigation of its Electrosensing Properties. Anal. Methods. 2016;8:1084–1090. doi: 10.1039/C5AY02672E. [DOI] [Google Scholar]
- Wang J. Sun H.-b. Pan H.-y. Ding Y.-y. Wan J.-g. Wang G.-h. Han M. Detection of Hydrogen Peroxide at a Palladium Nanoparticle-Bilayer Graphene Hybrid-Modified Electrode. Sens. Actuators, B. 2016;230:690–696. doi: 10.1016/j.snb.2016.02.117. [DOI] [Google Scholar]
- Ning L. Liu Y. Ma J. Fan X. Zhang G. Zhang F. Peng W. Li Y. Synthesis of Palladium, ZnFe2O4 Functionalized Reduced Graphene Oxide Nanocomposites as H2O2 Detector. Ind. Eng. Chem. Res. 2017;56:4327–4333. doi: 10.1021/acs.iecr.6b04964. [DOI] [Google Scholar]
- Velusamy V. Palanisamy S. Chen S.-M. Chen T.-W. Selvam S. Ramaraj S. K. Lou B.-S. Graphene Dispersed Cellulose Microfibers Composite for Efficient Immobilization of Hemoglobin and Selective Biosensor for Detection of Hydrogen Peroxide. Sens. Actuators, B. 2017;252:175–182. doi: 10.1016/j.snb.2017.05.041. [DOI] [Google Scholar]
- Qi Y. Bai J. Ding X. Zhang H.-M. Electrochemically Prepared Three-dimensional Porous Nitrogen-doped Graphene Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide. Electroanalysis. 2017;29:2083–2089. doi: 10.1002/elan.201700142. [DOI] [Google Scholar]
- Zhu Y. Lu S. Gowri Manohari A. Dong X. Chen F. Xu W. Shi Z. Xu C. Polydopamine Interconnected Graphene Quantum Dots and Gold Nanoparticles for Enzymeless H2O2 Detection. J. Electroanal. Chem. 2017;796:75–81. doi: 10.1016/j.jelechem.2017.04.017. [DOI] [Google Scholar]
- Liu Y. Liu X. Guo Z. Hu Z. Xue Z. Lu X. Horseradish Peroxidase Supported on Porous Graphene as a Novel Sensing Platform for Detection of Hydrogen Peroxide in Living Cells Sensitively. Biosens. Bioelectron. 2017;87:101–107. doi: 10.1016/j.bios.2016.08.015. [DOI] [PubMed] [Google Scholar]
- Sookhakian M. Zalnezhad E. Alias Y. Layer-by-Layer Electrodeposited Nanowall-Like Palladium-Reduced Graphene Oxide Film as a Highly-Sensitive Electrochemical Non-Enzymatic Sensor. Sens. Actuators, B. 2017;241:1–7. doi: 10.1016/j.snb.2016.10.053. [DOI] [Google Scholar]
- Mercante L. A. Facure M. H. M. Sanfelice R. C. Migliorini F. L. Mattoso L. H. C. Correa D. S. One-Pot Preparation of PEDOT:PSS-Reduced Graphene Decorated with Au Nanoparticles for Enzymatic Electrochemical Sensing of H2O2. Appl. Surf. Sci. 2017;407:162–170. doi: 10.1016/j.apsusc.2017.02.156. [DOI] [Google Scholar]
- Yusoff N. Rameshkumar P. Mehmood M. S. Pandikumar A. Lee H. W. Huang N. M. Ternary Nanohybrid of Reduced Graphene Oxide-Nafion@Silver Nanoparticles for Boosting the Sensor Performance in Non-Enzymatic Amperometric Detection of Hydrogen Peroxide. Biosens. Bioelectron. 2017;87:1020–1028. doi: 10.1016/j.bios.2016.09.045. [DOI] [PubMed] [Google Scholar]
- Karthikeyan C. Ramachandran K. Sheet S. Yoo D. J. Lee Y. S. kumar Y. S. Kim A. R. kumar G. G. Pigeon-Excreta-Mediated Synthesis of Reduced Graphene Oxide (rGO)/CuFe2O4 Nanocomposite and Its Catalytic Activity toward Sensitive and Selective Hydrogen Peroxide Detection. ACS Sustainable Chem. Eng. 2017;5:4897–4905. doi: 10.1021/acssuschemeng.7b00314. [DOI] [Google Scholar]
- Cheng C. Zhang C. Gao X. Zhuang Z. Du C. Chen W. 3D Network and 2D Paper of Reduced Graphene Oxide/Cu2O Composite for Electrochemical Sensing of Hydrogen Peroxide. Anal. Chem. 2018;90:1983–1991. doi: 10.1021/acs.analchem.7b04070. [DOI] [PubMed] [Google Scholar]
- Kubendhiran S. Thirumalraj B. Chen S.-M. Karuppiah C. Electrochemical Co-Preparation of Cobalt Sulfide/Reduced Graphene Oxide Composite for Electrocatalytic Activity and Determination of H2O2 in Biological Samples. J. Colloid Interface Sci. 2018;509:153–162. doi: 10.1016/j.jcis.2017.08.087. [DOI] [PubMed] [Google Scholar]
- Bai Z. Dong W. Ren Y. Zhang C. Chen Q. Preparation of Nano Au and Pt Alloy Microspheres Decorated with Reduced Graphene Oxide for Nonenzymatic Hydrogen Peroxide Sensing. Langmuir. 2018;34:2235–2244. doi: 10.1021/acs.langmuir.7b02626. [DOI] [PubMed] [Google Scholar]
- Sun C.-L. Su J.-S. Lai S.-Y. Lu Y.-J. Size Effects of Pt Nanoparticle/Graphene Composite Materials on the Electrochemical Sensing of Hydrogen Peroxide. J. Nanomater. 2015;2015:861061. [Google Scholar]
- Chen S. Yuan R. Chai Y. Hu F. Electrochemical Sensing of Hydrogen Peroxide Using Metal Nanoparticles: A Review. Microchim. Acta. 2013;180:15–32. doi: 10.1007/s00604-012-0904-4. [DOI] [Google Scholar]
- Guo S. Wen D. Zhai Y. Dong S. Wang E. Platinum Nanoparticle Ensemble-on-Graphene Hybrid Nanosheet: One-Pot, Rapid Synthesis, and Used as New Electrode Material for Electrochemical Sensing. ACS Nano. 2010;4:3959–3968. doi: 10.1021/nn100852h. [DOI] [PubMed] [Google Scholar]
- Zhan B. Liu C. Shi H. Li C. Wang L. Huang W. Dong X. A Hydrogen Peroxide Electrochemical Sensor Based on Silver Nanoparticles Decorated Three-Dimensional Graphene. Appl. Phys. Lett. 2014;104:243704. doi: 10.1063/1.4884418. [DOI] [Google Scholar]
- Yu B. Feng J. Liu S. Zhang T. Preparation of Reduced Graphene Oxide Decorated with High Density Ag Nanorods for Non-Enzymatic Hydrogen Peroxide Detection. RSC Adv. 2013;3:14303–14307. doi: 10.1039/C3RA41755G. [DOI] [Google Scholar]
- Chen D. Zhuang X. Zhai J. Zheng Y. Lu H. Chen L. Preparation of Highly Sensitive Pt Nanoparticles-Carbon Quantum Dots/Ionic Liquid Functionalized Graphene Oxide Nanocomposites and Application for H2O2 Detection. Sens. Actuators, B. 2018;255:1500–1506. doi: 10.1016/j.snb.2017.08.156. [DOI] [Google Scholar]
- Sun Y. Luo M. Qin Y. Zhu S. Li Y. Xu N. Meng X. Ren Q. Wang L. Guo S. Atomic-Thick PtNi Nanowires Assembled on Graphene for High-Sensitivity Extracellular Hydrogen Peroxide Sensors. ACS Appl. Mater. Interfaces. 2017;9:34715–34721. doi: 10.1021/acsami.7b11758. [DOI] [PubMed] [Google Scholar]
- Chen C. Yang Q.-H. Yang Y. Lv W. Wen Y. Hou P.-X. Wang M. Cheng H.-M. Self-Assembled Free-Standing Graphite Oxide Membrane. Adv. Mater. 2009;21:3007–3011. doi: 10.1002/adma.200803726. [DOI] [Google Scholar]
- Qiu H.-J. Guan Y. Luo P. Wang Y. Recent Advance in Fabricating Monolithic 3D Porous Graphene and Their Applications in Biosensing and Biofuel Cells. Biosens. Bioelectron. 2017;89:85–95. doi: 10.1016/j.bios.2015.12.029. [DOI] [PubMed] [Google Scholar]
- Cong H.-P. Chen J.-F. Yu S.-H. Graphene-Based Macroscopic Assemblies and Architectures: An Emerging Material System. Chem. Soc. Rev. 2014;43:7295–7325. doi: 10.1039/C4CS00181H. [DOI] [PubMed] [Google Scholar]
- Lin D. Su Z. Wei G. Three-Dimensional Porous Reduced Graphene Oxide Decorated with MoS2 Quantum Dots for Electrochemical Determination of Hydrogen Peroxide. Mater. Today Chem. 2018;7:76–83. doi: 10.1016/j.mtchem.2018.02.001. [DOI] [Google Scholar]
- Zhang T. Gu Y. Li C. Yan X. Lu N. Liu H. Zhang Z. Zhang H. Fabrication of Novel Electrochemical Biosensor Based on Graphene Nanohybrid to Detect H2O2 Released from Living Cells with Ultrahigh Performance. ACS Appl. Mater. Interfaces. 2017;9:37991–37999. doi: 10.1021/acsami.7b14029. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Xiao J. Lv Q. Wang L. Dong X. Asif M. Ren J. He W. Sun Y. Xiao F. Wang S. In situ Electrochemical Sensing and Real-Time Monitoring Live Cells Based on Freestanding Nanohybrid Paper Electrode Assembled from 3D Functionalized Graphene Framework. ACS Appl. Mater. Interfaces. 2017;9:38201–38210. doi: 10.1021/acsami.7b08781. [DOI] [PubMed] [Google Scholar]
- Ju J. Chen W. In situ Growth of Surfactant-Free Gold Nanoparticles on Nitrogen-Doped Graphene Quantum Dots for Electrochemical Detection of Hydrogen Peroxide in Biological Environments. Anal. Chem. 2015;87:1903–1910. doi: 10.1021/ac5041555. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Bai X. Wang X. Shiu K.-K. Zhu Y. Jiang H. Highly Sensitive Graphene–Pt Nanocomposites Amperometric Biosensor and Its Application in Living Cell H2O2 Detection. Anal. Chem. 2014;86:9459–9465. doi: 10.1021/ac5009699. [DOI] [PubMed] [Google Scholar]
- Wang L. Zhang Y. Cheng C. Liu X. Jiang H. Wang X. Highly Sensitive Electrochemical Biosensor for Evaluation of Oxidative Stress Based on the Nanointerface of Graphene Nanocomposites Blended with Gold, Fe3O4, and Platinum Nanoparticles. ACS Appl. Mater. Interfaces. 2015;7:18441–18449. doi: 10.1021/acsami.5b04553. [DOI] [PubMed] [Google Scholar]
- Sun Y. Luo M. Meng X. Xiang J. Wang L. Ren Q. Guo S. Graphene/Intermetallic PtPb Nanoplates Composites for Boosting Electrochemical Detection of H2O2 Released from Cells. Anal. Chem. 2017;89:3761–3767. doi: 10.1021/acs.analchem.7b00248. [DOI] [PubMed] [Google Scholar]
- He Y. Huang G. Cui H. Quenching the Chemiluminescence of Acridinium Ester by Graphene Oxide for Label-Free and Homogeneous DNA Detection. ACS Appl. Mater. Interfaces. 2013;5:11336–11340. doi: 10.1021/am404138x. [DOI] [PubMed] [Google Scholar]
- Cervenka J. Budi A. Dontschuk N. Stacey A. Tadich A. Rietwyk K. J. Schenk A. Edmonds M. T. Yin Y. Medhekar N. Kalbac M. Pakes C. I. Graphene Field Effect Transistor as a Probe of Electronic Structure and Charge Transfer at Organic Molecule–Graphene Interfaces. Nanoscale. 2015;7:1471–1478. doi: 10.1039/C4NR05390G. [DOI] [PubMed] [Google Scholar]
- Premkumar T. Geckeler K. E. Graphene–DNA Hybrid Materials: Assembly, Applications, and Prospects. Prog. Polym. Sci. 2012;37:515–529. doi: 10.1016/j.progpolymsci.2011.08.003. [DOI] [Google Scholar]
- Zhu X. Sun L. Chen Y. Ye Z. Shen Z. Li G. Combination of Cascade Chemical Reactions with Graphene–DNA Interaction to Develop New Strategy for Biosensor Fabrication. Biosens. Bioelectron. 2013;47:32–37. doi: 10.1016/j.bios.2013.02.039. [DOI] [PubMed] [Google Scholar]
- Dontschuk N. Stacey A. Tadich A. Rietwyk K. J. Schenk A. Edmonds M. T. Shimoni O. Pakes C. I. Prawer S. Cervenka J. A Graphene Field-Effect Transistor as a Molecule-Specific Probe of DNA Nucleobases. Nat. Commun. 2015;6:6563. doi: 10.1038/ncomms7563. [DOI] [PubMed] [Google Scholar]
- Lee J.-H. Choi Y.-K. Kim H.-J. Scheicher R. H. Cho J.-H. Physisorption of DNA Nucleobases on h-BN and Graphene: vdW-Corrected DFT Calculations. J. Phys. Chem. C. 2013;117:13435–13441. doi: 10.1021/jp402403f. [DOI] [Google Scholar]
- Yin Y. Cervenka J. Medhekar N. V. Molecular Dipole-Driven Electronic Structure Modifications of DNA/RNA Nucleobases on Graphene. J. Phys. Chem. Lett. 2017;8:3087–3094. doi: 10.1021/acs.jpclett.7b01283. [DOI] [PubMed] [Google Scholar]
- Liu A.-L. Zhong G.-X. Chen J.-Y. Weng S.-H. Huang H.-N. Chen W. Lin L.-Q. Lei Y. Fu F.-H. Sun Z.-l. Lin X.-H. Lin J.-H. Yang S.-Y. A Sandwich-Type DNA Biosensor Based on Electrochemical Co-Reduction Synthesis of Graphene-Three Dimensional Nanostructure Gold Nanocomposite Films. Anal. Chim. Acta. 2013;767:50–58. doi: 10.1016/j.aca.2012.12.049. [DOI] [PubMed] [Google Scholar]
- Yang T. Li Q. Meng L. Wang X. Chen W. Jiao K. Synchronous Electrosynthesis of Poly(xanthurenic acid)-Reduced Graphene Oxide Nanocomposite for Highly Sensitive Impedimetric Detection of DNA. ACS Appl. Mater. Interfaces. 2013;5:3495–3499. doi: 10.1021/am400370s. [DOI] [PubMed] [Google Scholar]
- Yang T. Meng L. Wang X. Wang L. Jiao K. Direct Electrochemical DNA Detection Originated from the Self-Redox Signal of Sulfonated Polyaniline Enhanced by Graphene Oxide in Neutral Solution. ACS Appl. Mater. Interfaces. 2013;5:10889–10894. doi: 10.1021/am403090y. [DOI] [PubMed] [Google Scholar]
- Benvidi A. Rajabzadeh N. Mazloum-Ardakani M. Heidari M. M. Mulchandani A. Simple and label-free electrochemical impedance amelogenin gene hybridization biosensing based on reduced graphene oxide. Biosens. Bioelectron. 2014;58:145–152. doi: 10.1016/j.bios.2014.01.053. [DOI] [PubMed] [Google Scholar]
- Peng H.-P. Hu Y. Liu P. Deng Y.-N. Wang P. Chen W. Liu A.-L. Chen Y.-Z. Lin X.-H. Label-Free Electrochemical DNA Biosensor for Rapid Detection of Mutidrug Resistance Gene Based on Au Nanoparticles/Toluidine Blue–Graphene Oxide Nanocomposites. Sens. Actuators, B. 2015;207:269–276. doi: 10.1016/j.snb.2014.10.059. [DOI] [Google Scholar]
- Huang H. Bai W. Dong C. Guo R. Liu Z. An Ultrasensitive Electrochemical DNA Biosensor Based on Graphene/Au Nanorod/Polythionine for Human Papillomavirus DNA Detection. Biosens. Bioelectron. 2015;68:442–446. doi: 10.1016/j.bios.2015.01.039. [DOI] [PubMed] [Google Scholar]
- Fang L.-X. Cao J.-T. Huang K.-J. A Sensitive Electrochemical Biosensor for Specific DNA Sequence Detection Based on Flower-Like VS2, Graphene and Au Nanoparticles Signal Amplification. J. Electroanal. Chem. 2015;746:1–8. doi: 10.1016/j.jelechem.2015.03.026. [DOI] [Google Scholar]
- Benvidi A. Firouzabadi A. D. Moshtaghiun S. M. Mazloum-Ardakani M. Tezerjani M. D. Ultrasensitive DNA Sensor Based on Gold Nanoparticles/Reduced Graphene Oxide/Glassy Carbon Electrode. Anal. Biochem. 2015;484:24–30. doi: 10.1016/j.ab.2015.05.009. [DOI] [PubMed] [Google Scholar]
- Wang Y. Bai X. Wen W. Zhang X. Wang S. Ultrasensitive Electrochemical Biosensor for HIV Gene Detection Based on Graphene Stabilized Gold Nanoclusters with Exonuclease Amplification. ACS Appl. Mater. Interfaces. 2015;7:18872–18879. doi: 10.1021/acsami.5b05857. [DOI] [PubMed] [Google Scholar]
- Li B. Pan G. Avent N. D. Lowry R. B. Madgett T. E. Waines P. L. Graphene Electrode Modified with Electrochemically Reduced Graphene Oxide for Label-Free DNA Detection. Biosens. Bioelectron. 2015;72:313–319. doi: 10.1016/j.bios.2015.05.034. [DOI] [PubMed] [Google Scholar]
- Wang W. Bao T. Zeng X. Xiong H. Wen W. Zhang X. Wang S. Ultrasensitive Electrochemical DNA Biosensor Based on Functionalized Gold Clusters/Graphene Nanohybrids Coupling with Exonuclease III-Aided Cascade Target Recycling. Biosens. Bioelectron. 2017;91:183–189. doi: 10.1016/j.bios.2016.12.017. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Z. Jiang W. Decorating Graphene Sheets with Gold Nanoparticles for the Detection of Sequence-Specific DNA. Electrochim. Acta. 2012;71:239–245. doi: 10.1016/j.electacta.2012.03.136. [DOI] [Google Scholar]
- Liu C. Jiang D. Xiang G. Liu L. Liu F. Pu X. An Electrochemical DNA Biosensor for the Detection of Mycobacterium tuberculosis, Based on Signal Amplification of Graphene and a Gold Nanoparticle–Polyaniline Nanocomposite. Analyst. 2014;139:5460–5465. doi: 10.1039/C4AN00976B. [DOI] [PubMed] [Google Scholar]
- Wu A. Wang Q. Zhu Q. Ni J. Gao F. A Facile and Highly Sensitive Impedimetric DNA Biosensor with Ultralow Background Response Based on In situ Reduced Graphene Oxide. RSC Adv. 2015;5:90983–90990. doi: 10.1039/C5RA16233E. [DOI] [Google Scholar]
- Chen M. Hou C. Huo D. Bao J. Fa H. Shen C. An electrochemical DNA biosensor based on nitrogen-doped graphene/Au nanoparticles for human multidrug resistance gene detection. Biosens. Bioelectron. 2016;85:684–691. doi: 10.1016/j.bios.2016.05.051. [DOI] [PubMed] [Google Scholar]
- Zhang K. Zhang N. Zhang L. Wang H. Shi H. Liu Q. Label-free impedimetric sensing platform for microRNA-21 based on ZrO2-reduced graphene oxide nanohybrids coupled with catalytic hairpin assembly amplification. RSC Adv. 2018;8:16146–16151. doi: 10.1039/C8RA02453G. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gao N. Gao F. He S. Zhu Q. Huang J. Tanaka H. Wang Q. Graphene Oxide Directed in situ Deposition of Electroactive Silver Nanoparticles and its Electrochemical Sensing Application for DNA Analysis. Anal. Chim. Acta. 2017;951:58–67. doi: 10.1016/j.aca.2016.11.033. [DOI] [PubMed] [Google Scholar]
- Gong Q. Wang Y. Yang H. A Sensitive Impedimetric DNA Biosensor for the Determination of the HIV Gene Based on Graphene-Nafion Composite Film. Biosens. Bioelectron. 2017;89:565–569. doi: 10.1016/j.bios.2016.02.045. [DOI] [PubMed] [Google Scholar]
- Gong Q. Yang H. Dong Y. Zhang W. A Sensitive Impedimetric DNA Biosensor for the Determination of the HIV Gene Based on Electrochemically Reduced Graphene Oxide. Anal. Methods. 2015;7:2554–2562. doi: 10.1039/C5AY00111K. [DOI] [Google Scholar]
- Niu X. Zheng W. Yin C. Weng W. Li G. Sun W. Men Y. Electrochemical DNA Biosensor Based on Gold Nanoparticles and Partially Reduced Graphene Oxide Modified Electrode for the Detection of Listeria monocytogenes Hly Gene Sequence. J. Electroanal. Chem. 2017;806:116–122. doi: 10.1016/j.jelechem.2017.10.049. [DOI] [Google Scholar]
- Yang T. Chen H. Qiu Z. Yu R. Luo S. Li W. Jiao K. Direct Electrochemical Vibrio DNA Sensing Adopting Highly Stable Graphene–Flavin Mononucleotide Aqueous Dispersion Modified Interface. ACS Appl. Mater. Interfaces. 2018;10:4540–4547. doi: 10.1021/acsami.7b18212. [DOI] [PubMed] [Google Scholar]
- Arvand M. Sanayeei M. Hemmati S. Label-Free Electrochemical DNA Biosensor for Guanine and Adenine by ds-DNA/Poly(L-Cysteine)/Fe3O4 Nanoparticles-Graphene Oxide Nanocomposite Modified Electrode. Biosens. Bioelectron. 2018;102:70–79. doi: 10.1016/j.bios.2017.11.002. [DOI] [PubMed] [Google Scholar]
- Loan P. T. K. Wu D. Ye C. Li X. Tra V. T. Wei Q. Fu L. Yu A. Li L.-J. Lin C.-T. Hall Effect Biosensors with Ultraclean Graphene Film for Improved Sensitivity of Label-Free DNA Detection. Biosens. Bioelectron. 2018;99:85–91. doi: 10.1016/j.bios.2017.07.045. [DOI] [PubMed] [Google Scholar]
- Imran H. Manikandan P. N. Dharuman V. Graphene Oxide Supported Liposomes for Efficient Label Free Electrochemical DNA Biosensing. Sens. Actuators, B. 2018;260:841–851. doi: 10.1016/j.snb.2018.01.103. [DOI] [Google Scholar]
- Ye Y. Xie J. Ye Y. Cao X. Zheng H. Xu X. Zhang Q. A Label-Free Electrochemical DNA Biosensor Based on Thionine Functionalized Reduced Graphene Oxide. Carbon. 2018;129:730–737. doi: 10.1016/j.carbon.2017.12.060. [DOI] [Google Scholar]
- Jamaluddin R. Z. A. R. Heng L. Y. Tan L. L. Chong K. F. A Biosensor for Genetic Modified Soybean DNA Determination via Adsorption of Anthraquinone-2-Sulphonic Acid in Reduced Graphene Oxide. Electroanalysis. 2018;30:250–258. doi: 10.1002/elan.201700612. [DOI] [Google Scholar]
- Feng Q. Zhao X. Guo Y. Liu M. Wang P. Stochastic DNA Walker for Electrochemical Biosensing Sensitized with Gold Nanocages@Graphene Nanoribbons. Biosens. Bioelectron. 2018;108:97–102. doi: 10.1016/j.bios.2018.02.050. [DOI] [PubMed] [Google Scholar]
- Hu T. Zhang L. Wen W. Zhang X. Wang S. Enzyme Catalytic Amplification of miRNA-155 Detection with Graphene Quantum Dot-Based Electrochemical Biosensor. Biosens. Bioelectron. 2016;77:451–456. doi: 10.1016/j.bios.2015.09.068. [DOI] [PubMed] [Google Scholar]
- Azimzadeh M. Rahaie M. Nasirizadeh N. Ashtari K. Naderi-Manesh H. An Electrochemical Nanobiosensor for Plasma miRNA-155, Based on Graphene Oxide and Gold Nanorod, for Early Detection of Breast Cancer. Biosens. Bioelectron. 2016;77:99–106. doi: 10.1016/j.bios.2015.09.020. [DOI] [PubMed] [Google Scholar]
- Shuai H.-L. Huang K.-J. Zhang W.-J. Cao X. Jia M.-P. Sandwich-Type microRNA Biosensor Based on Magnesium Oxide Nanoflower and Graphene Oxide–Gold Nanoparticles Hybrids Coupling with Enzyme Signal Amplification. Sens. Actuators, B. 2017;243:403–411. doi: 10.1016/j.snb.2016.12.001. [DOI] [Google Scholar]
- Eksin E. Bikkarolla S. K. Erdem A. Papakonstantinou P. Chitosan/Nitrogen Doped Reduced Graphene Oxide Modified Biosensor for Impedimetric Detection of microRNA. Electroanalysis. 2018;30:551–560. doi: 10.1002/elan.201700663. [DOI] [Google Scholar]
- Wang Y.-H. Huang K.-J. Wu X. Ma Y.-Y. Song D.-L. Du C.-Y. Chang S.-H. Ultrasensitive Supersandwich-Type Biosensor for Enzyme-Free Amplified microRNA Detection Based on N-Doped Graphene/Au Nanoparticles and Hemin/G-Quadruplexes. J. Mater. Chem. B. 2018;6:2134–2142. doi: 10.1039/C8TB00061A. [DOI] [PubMed] [Google Scholar]
- Gai P.-P. Zhao C.-E. Wang Y. Abdel-Halim E. S. Zhang J.-R. Zhu J.-J. NADH Dehydrogenase-Like Behavior of Nitrogen-Doped Graphene and Its Application in NAD+-Dependent Dehydrogenase Biosensing. Biosens. Bioelectron. 2014;62:170–176. doi: 10.1016/j.bios.2014.06.043. [DOI] [PubMed] [Google Scholar]
- Li Z. Su W. Liu S. Ding X. An Electrochemical Biosensor Based on DNA Tetrahedron/Graphene Composite Film for Highly Sensitive Detection of NADH. Biosens. Bioelectron. 2015;69:287–293. doi: 10.1016/j.bios.2015.02.031. [DOI] [PubMed] [Google Scholar]
- Govindhan M. Amiri M. Chen A. Au Nanoparticle/Graphene Nanocomposite as a Platform for the Sensitive Detection of NADH in Human Urine. Biosens. Bioelectron. 2015;66:474–480. doi: 10.1016/j.bios.2014.12.012. [DOI] [PubMed] [Google Scholar]
- Sangamithirai D. Narayanan V. Muthuraaman B. Stephen A. Investigations on the Performance of Poly(O-Anisidine)/Graphene Nanocomposites for the Electrochemical Detection of NADH. Mater. Sci. Eng., C. 2015;55:579–591. doi: 10.1016/j.msec.2015.05.066. [DOI] [PubMed] [Google Scholar]
- Mutyala S. Mathiyarasu J. A Highly Sensitive NADH Biosensor Using Nitrogen Doped Graphene Modified Electrodes. J. Electroanal. Chem. 2016;775:329–336. doi: 10.1016/j.jelechem.2016.06.011. [DOI] [Google Scholar]
- Istrate O.-M. Rotariu L. Marinescu V. E. Bala C. NADH Sensing Platform Based on Electrochemically Generated Reduced Graphene Oxide–Gold Nanoparticles Composite Stabilized With Poly(Allylamine Hydrochloride) Sens. Actuators, B. 2016;223:697–704. doi: 10.1016/j.snb.2015.09.142. [DOI] [Google Scholar]
- Balamurugan J. Thanh T. D. Kim N. H. Lee J. H. Facile Fabrication of FeN Nanoparticles/Nitrogen-Doped Graphene Core-Shell Hybrid and Its Use as a Platform for NADH Detection in Human Blood Serum. Biosens. Bioelectron. 2016;83:68–76. doi: 10.1016/j.bios.2016.04.040. [DOI] [PubMed] [Google Scholar]
- Han S. Du T. Jiang H. Wang X. Synergistic Effect of Pyrroloquinoline Quinone and Graphene Nano-Interface for Facile Fabrication of Sensitive NADH Biosensor. Biosens. Bioelectron. 2017;89:422–429. doi: 10.1016/j.bios.2016.04.092. [DOI] [PubMed] [Google Scholar]
- Tığ G. A. Highly Sensitive Amperometric Biosensor for Determination of NADH and Ethanol Based on Au-Ag Nanoparticles/Poly(L-Cysteine)/Reduced Graphene Oxide Nanocomposite. Talanta. 2017;175:382–389. doi: 10.1016/j.talanta.2017.07.073. [DOI] [PubMed] [Google Scholar]
- Wang J. Shi A. Fang X. Han X. Zhang Y. An Ultrasensitive Supersandwich Electrochemical DNA Biosensor Based on Gold Nanoparticles Decorated Reduced Graphene Oxide. Anal. Biochem. 2015;469:71–75. doi: 10.1016/j.ab.2014.09.023. [DOI] [PubMed] [Google Scholar]
- Wang Q. Lei J. Deng S. Zhang L. Ju H. Graphene-Supported Ferric Porphyrin as a Peroxidase Mimic for Electrochemical DNA Biosensing. Chem. Commun. 2013;49:916–918. doi: 10.1039/C2CC37664D. [DOI] [PubMed] [Google Scholar]
- Singh A. Sinsinbar G. Choudhary M. Kumar V. Pasricha R. Verma H. N. Singh S. P. Arora K. Graphene Oxide-Chitosan Nanocomposite Based Electrochemical DNA Biosensor for Detection of Typhoid. Sens. Actuators, B. 2013;185:675–684. doi: 10.1016/j.snb.2013.05.014. [DOI] [Google Scholar]
- Han X. Fang X. Shi A. Wang J. Zhang Y. An Electrochemical DNA Biosensor Based on Gold Nanorods Decorated Graphene Oxide Sheets for Sensing Platform. Anal. Biochem. 2013;443:117–123. doi: 10.1016/j.ab.2013.08.027. [DOI] [PubMed] [Google Scholar]
- Jayakumar K. Camarada M. B. Dharuman V. Rajesh R. Venkatesan R. Ju H. Maniraj M. Rai A. Barman S. R. wen Y. Layer-by-Layer-Assembled AuNPs-Decorated First-Generation Poly(amidoamine) Dendrimer with Reduced Graphene Oxide Core as Highly Sensitive Biosensing Platform with Controllable 3D Nanoarchitecture for Rapid Voltammetric Analysis of Ultratrace DNA Hybridization. ACS Appl. Mater. Interfaces. 2018;10:21541–21555. doi: 10.1021/acsami.8b03236. [DOI] [PubMed] [Google Scholar]
- Traversi F. Raillon C. Benameur S. M. Liu K. Khlybov S. Tosun M. Krasnozhon D. Kis A. Radenovic A. Detecting the Translocation of DNA Through a Nanopore Using Graphene Nanoribbons. Nat. Nanotechnol. 2013;8:939–945. doi: 10.1038/nnano.2013.240. [DOI] [PubMed] [Google Scholar]
- Min S. K. Kim W. Y. Cho Y. Kim K. S. Fast DNA Sequencing with a Graphene-Based Nanochannel Device. Nat. Nanotechnol. 2011;6:162–165. doi: 10.1038/nnano.2010.283. [DOI] [PubMed] [Google Scholar]
- Heerema S. J. Dekker C. Graphene Nanodevices for DNA Sequencing. Nat. Nanotechnol. 2016;11:127–136. doi: 10.1038/nnano.2015.307. [DOI] [PubMed] [Google Scholar]
- Avdoshenko S. M. Nozaki D. da Rocha C. G. González J. W. Lee M. H. Gutierrez R. Cuniberti G. Dynamic and Electronic Transport Properties of DNA Translocation through Graphene Nanopores. Nano Lett. 2013;13:1969–1976. doi: 10.1021/nl304735k. [DOI] [PubMed] [Google Scholar]
- Sadeghi H. Algaragholy L. Pope T. Bailey S. Visontai D. Manrique D. Ferrer J. Garcia-Suarez V. Sangtarash S. Lambert C. J. Graphene Sculpturene Nanopores for DNA Nucleobase Sensing. J. Phys. Chem. B. 2014;118:6908–6914. doi: 10.1021/jp5034917. [DOI] [PubMed] [Google Scholar]
- Hunt E. A. Broyles D. Head T. Deo S. K. MicroRNA Detection: Current Technology and Research Strategies. Annu. Rev. Anal. Chem. 2015;8:217–237. doi: 10.1146/annurev-anchem-071114-040343. [DOI] [PubMed] [Google Scholar]
- Chen Y.-X. Huang K.-J. Niu K.-X. Recent Advances in Signal Amplification Strategy Based on Oligonucleotide and Nanomaterials for MicroRNA Detection-A Review. Biosens. Bioelectron. 2018;99:612–624. doi: 10.1016/j.bios.2017.08.036. [DOI] [PubMed] [Google Scholar]
- Kilic T. Erdem A. Ozsoz M. Carrara S. MicroRNA Biosensors: Opportunities and Challenges among Conventional and Commercially Available Techniques. Biosens. Bioelectron. 2018;99:525–546. doi: 10.1016/j.bios.2017.08.007. [DOI] [PubMed] [Google Scholar]
- Cardoso A. R. Moreira F. T. C. Fernandes R. Sales M. G. F. Novel and Simple Electrochemical Biosensor Monitoring Attomolar Levels of miRNA-155 in Breast Cancer. Biosens. Bioelectron. 2016;80:621–630. doi: 10.1016/j.bios.2016.02.035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li Z. Huang Y. Chen L. Qin X. Huang Z. Zhou Y. Meng Y. Li J. Huang S. Liu Y. Wang W. Xie Q. Yao S. Amperometric Biosensor for NADH and Ethanol Based on Electroreduced Graphene Oxide–Polythionine Nanocomposite Film. Sens. Actuators, B. 2013;181:280–287. doi: 10.1016/j.snb.2013.01.072. [DOI] [Google Scholar]
- Tabrizi M. A. Zand Z. A Facile One-Step Method for the Synthesis of Reduced Graphene Oxide Nanocomposites by NADH as Reducing Agent and Its Application in NADH Sensing. Electroanalysis. 2013;26:171–177. doi: 10.1002/elan.201300370. [DOI] [Google Scholar]
- Savitt J. M. Dawson V. L. Dawson T. M. Diagnosis and Treatment of Parkinson Disease: Molecules to Medicine. J. Clin. Invest. 2006;116:1744–1754. doi: 10.1172/JCI29178. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Xiao T. Wu F. Hao J. Zhang M. Yu P. Mao L. In vivo Analysis with Electrochemical Sensors and Biosensors. Anal. Chem. 2017;89:300–313. doi: 10.1021/acs.analchem.6b04308. [DOI] [PubMed] [Google Scholar]
- Schmidt A. C. Wang X. Zhu Y. Sombers L. A. Carbon Nanotube Yarn Electrodes for Enhanced Detection of Neurotransmitter Dynamics in Live Brain Tissue. ACS Nano. 2013;7:7864–7873. doi: 10.1021/nn402857u. [DOI] [PubMed] [Google Scholar]
- Zhang M. Yu P. Mao L. Rational Design of Surface/Interface Chemistry for Quantitative In vivo Monitoring of Brain Chemistry. Acc. Chem. Res. 2012;45:533–543. doi: 10.1021/ar200196h. [DOI] [PubMed] [Google Scholar]
- Falat L. Cheng H. Y. Voltammetric Differentiation of Ascorbic Acid and Dopamine at an Electrochemically Treated Graphite/Epoxy Electrode. Anal. Chem. 1982;54:2108–2111. doi: 10.1021/ac00249a046. [DOI] [Google Scholar]
- Zhang L. Lin X. Sun Y. Separation of Anodic Peaks of Ascorbic Acid and Dopamine at an A-Alanine Covalently Modified Glassy Carbon Electrode. Analyst. 2001;126:1760–1763. doi: 10.1039/B104886B. [DOI] [Google Scholar]
- Mao X. Rutledge G. C. Hatton T. A. Nanocarbon-Based Electrochemical Systems for Sensing, Electrocatalysis, and Energy Storage. Nano Today. 2014;9:405–432. doi: 10.1016/j.nantod.2014.06.011. [DOI] [Google Scholar]
- Ambrosi A. Sasaki T. Pumera M. Platelet Graphite Nanofibers for Electrochemical Sensing and Biosensing: The Influence of Graphene Sheet Orientation. Chem.–Asian J. 2010;5:266–271. doi: 10.1002/asia.200900544. [DOI] [PubMed] [Google Scholar]
- Devaramani S. Sreeramareddygari M. Reddy M. R. Thippeswamy R. Covalently Anchored p-Aminobenzene Sulfonate Multilayer on a Graphite Pencil Lead Electrode: A Highly Selective Electrochemical Sensor for Dopamine. Electroanalysis. 2017;29:1410–1417. doi: 10.1002/elan.201600627. [DOI] [Google Scholar]
- Gao F. Cai X. Wang X. Gao C. Liu S. Gao F. Wang Q. Highly Sensitive and Selective Detection of Dopamine in the Presence of Ascorbic Acid at Graphene Oxide Modified Electrode. Sens. Actuators, B. 2013;186:380–387. doi: 10.1016/j.snb.2013.06.020. [DOI] [Google Scholar]
- Li S. Ma Y. Liu Y. Xin G. Wang M. Zhang Z. Liu Z. Electrochemical sensor based on a three dimensional nanostructured MoS2 nanosphere-PANI/reduced graphene oxide composite for simultaneous detection of ascorbic acid, dopamine, and uric acid. RSC Adv. 2019;9:2997–3003. doi: 10.1039/C8RA09511F. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim Y.-R. Bong S. Kang Y.-J. Yang Y. Mahajan R. K. Kim J. S. Kim H. Electrochemical Detection of Dopamine in the Presence of Ascorbic Acid Using Graphene Modified Electrodes. Biosens. Bioelectron. 2010;25:2366–2369. doi: 10.1016/j.bios.2010.02.031. [DOI] [PubMed] [Google Scholar]
- Sun C.-L. Lee H.-H. Yang J.-M. Wu C.-C. The Simultaneous Electrochemical Detection of Ascorbic Acid, Dopamine, and Uric Acid Using Graphene/Size-Selected Pt Nanocomposites. Biosens. Bioelectron. 2011;26:3450–3455. doi: 10.1016/j.bios.2011.01.023. [DOI] [PubMed] [Google Scholar]
- Sun C.-L. Chang C.-T. Lee H.-H. Zhou J. Wang J. Sham T.-K. Pong W.-F. Microwave-Assisted Synthesis of a Core–Shell MWCNT/GONR Heterostructure for the Electrochemical Detection of Ascorbic Acid, Dopamine, and Uric Acid. ACS Nano. 2011;5:7788–7795. doi: 10.1021/nn2015908. [DOI] [PubMed] [Google Scholar]
- Sheng Z.-H. Zheng X.-Q. Xu J.-Y. Bao W.-J. Wang F.-B. Xia X.-H. Electrochemical Sensor Based on Nitrogen Doped Graphene: Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid. Biosens. Bioelectron. 2012;34:125–131. doi: 10.1016/j.bios.2012.01.030. [DOI] [PubMed] [Google Scholar]
- Ping J. Wu J. Wang Y. Ying Y. Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid Using High-Performance Screen-Printed Graphene Electrode. Biosens. Bioelectron. 2012;34:70–76. doi: 10.1016/j.bios.2012.01.016. [DOI] [PubMed] [Google Scholar]
- Tian X. Cheng C. Yuan H. Du J. Xiao D. Xie S. Choi M. M. F. Simultaneous Determination of L-Ascorbic Acid, Dopamine and Uric Acid With Gold Nanoparticles–β-Cyclodextrin–Graphene-Modified Electrode by Square Wave Voltammetry. Talanta. 2012;93:79–85. doi: 10.1016/j.talanta.2012.01.047. [DOI] [PubMed] [Google Scholar]
- Wang X. Wu M. Tang W. Zhu Y. Wang L. Wang Q. He P. Fang Y. Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Using a Palladium Nanoparticle/Graphene/Chitosan Modified Electrode. J. Electroanal. Chem. 2013;695:10–16. doi: 10.1016/j.jelechem.2013.02.021. [DOI] [Google Scholar]
- Zhang H. Gai P. Cheng R. Wu L. Zhang X. Chen J. Self-Assembly Synthesis of a Hierarchical Structure Using Hollow Nitrogen-Doped Carbon Spheres as Spacers to Separate the Reduced Graphene Oxide for Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid. Anal. Methods. 2013;5:3591–3600. doi: 10.1039/C3AY40572A. [DOI] [Google Scholar]
- Weng X. Cao Q. Liang L. Chen J. You C. Ruan Y. Lin H. Wu L. Simultaneous Determination of Dopamine and Uric Acid Using Layer-by-Layer Graphene and Chitosan Assembled Multilayer Films. Talanta. 2013;117:359–365. doi: 10.1016/j.talanta.2013.09.023. [DOI] [PubMed] [Google Scholar]
- Manivel P. Dhakshnamoorthy M. Balamurugan A. Ponpandian N. Mangalaraj D. Viswanathan C. Conducting Polyaniline-Graphene Oxide Fibrous Nanocomposites: Preparation, Characterization and Simultaneous Electrochemical Detection of Ascorbic Acid, Dopamine and Uric Acid. RSC Adv. 2013;3:14428–14437. doi: 10.1039/C3RA42322K. [DOI] [Google Scholar]
- Lian Q. He Z. He Q. Luo A. Yan K. Zhang D. Lu X. Zhou X. Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Tryptophan Functionalized Graphene. Anal. Chim. Acta. 2014;823:32–39. doi: 10.1016/j.aca.2014.03.032. [DOI] [PubMed] [Google Scholar]
- Liu X. Zhang L. Wei S. Chen S. Ou X. Lu Q. Overoxidized Polyimidazole/Graphene Oxide Copolymer Modified Electrode for the Simultaneous Determination of Ascorbic Acid, Dopamine, Uric Acid, Guanine and Adenine. Biosens. Bioelectron. 2014;57:232–238. doi: 10.1016/j.bios.2014.02.017. [DOI] [PubMed] [Google Scholar]
- Yang Y. J. Li W. CTAB Functionalized Graphene Oxide/Multiwalled Carbon Nanotube Composite Modified Electrode for the Simultaneous Determination of Ascorbic Acid, Dopamine, Uric Acid and Nitrite. Biosens. Bioelectron. 2014;56:300–306. doi: 10.1016/j.bios.2014.01.037. [DOI] [PubMed] [Google Scholar]
- Ramakrishnan S. Pradeep K. R. Raghul A. Senthilkumar R. Rangarajan M. Kothurkar N. K. One-Step Synthesis of Pt-Decorated Graphene–Carbon Nanotubes for the Electrochemical Sensing of Dopamine, Uric Acid and Ascorbic Acid. Anal. Methods. 2015;7:779–786. doi: 10.1039/C4AY02487G. [DOI] [Google Scholar]
- Qi S. Zhao B. Tang H. Jiang X. Determination of Ascorbic Acid, Dopamine, and Uric Acid by a Novel Electrochemical Sensor Based on Pristine Graphene. Electrochim. Acta. 2015;161:395–402. doi: 10.1016/j.electacta.2015.02.116. [DOI] [Google Scholar]
- Wang Q. Tang Q. Improved Sensing of Dopamine and Ascorbic Acid Using a Glassy Carbon Electrode Modified with Electrochemically Synthesized Nickel-Cobalt Hexacyanoferrate Microparticles Deposited on Graphene. Microchim. Acta. 2015;182:671–677. doi: 10.1007/s00604-014-1371-x. [DOI] [Google Scholar]
- Shieh Y.-T. Jiang H.-F. Graphene Oxide-Assisted Dispersion of Carbon Nanotubes in Sulfonated Chitosan-Modified Electrode for Selective Detections Of Dopamine, Uric Acid, and Ascorbic Acid. J. Electroanal. Chem. 2015;736:132–138. doi: 10.1016/j.jelechem.2014.11.008. [DOI] [Google Scholar]
- Li S.-M. Wang Y.-S. Hsiao S.-T. Liao W.-H. Lin C.-W. Yang S.-Y. Tien H.-W. Ma C.-C. M. Hu C.-C. Fabrication of a Silver Nanowire-Reduced Graphene Oxide-Based Electrochemical Biosensor and its Enhanced Sensitivity in the Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid. J. Mater. Chem. C. 2015;3:9444–9453. doi: 10.1039/C5TC01564B. [DOI] [Google Scholar]
- Zhang Y. Ji Y. Wang Z. Liu S. Zhang T. Electrodeposition Synthesis of Reduced Graphene Oxide–Carbon Nanotube Hybrids on Indium Tin Oxide Electrode for Simultaneous Electrochemical Detection of Ascorbic Acid, Dopamine and Uric Acid. RSC Adv. 2015;5:106307–106314. doi: 10.1039/C5RA24727F. [DOI] [Google Scholar]
- Jiang J. Du X. Sensitive Electrochemical Sensors for Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid Based on Au@Pd-Reduced Graphene Oxide Nanocomposites. Nanoscale. 2014;6:11303–11309. doi: 10.1039/C4NR01774A. [DOI] [PubMed] [Google Scholar]
- Biswas S. Das R. Chakraborty D. Bandhyopadhyay R. Pramanik P. Synthesis of Nitrogen Doped Multilayered Graphene Flakes: Selective Non-enzymatic Electrochemical Determination of Dopamine and Uric Acid in presence of Ascorbic Acid. Electroanalysis. 2015;27:1253–1261. doi: 10.1002/elan.201400617. [DOI] [Google Scholar]
- Zou H. L. Li B. L. Luo H. Q. Li N. B. A Novel Electrochemical Biosensor Based on Hemin Functionalized Graphene Oxide Sheets for Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid. Sens. Actuators, B. 2015;207:535–541. doi: 10.1016/j.snb.2014.10.121. [DOI] [Google Scholar]
- Chen L.-X. Zheng J.-N. Wang A.-J. Wu L.-J. Chen J.-R. Feng J.-J. Facile Synthesis of Porous Bimetallic Alloyed PdAg Nanoflowers Supported on Reduced Graphene Oxide for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid. Analyst. 2015;140:3183–3192. doi: 10.1039/C4AN02200A. [DOI] [PubMed] [Google Scholar]
- Cai W. Lai J. Lai T. Xie H. Ye J. Controlled Functionalization of Flexible Graphene Fibers for the Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid. Sens. Actuators, B. 2016;224:225–232. doi: 10.1016/j.snb.2015.09.079. [DOI] [Google Scholar]
- Zan X. Bai H. Wang C. Zhao F. Duan H. Graphene Paper Decorated with a 2D Array of Dendritic Platinum Nanoparticles for Ultrasensitive Electrochemical Detection of Dopamine Secreted by Live Cells. Chem.–Eur. J. 2016;22:5204–5210. doi: 10.1002/chem.201504454. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang X. Zhang Y.-C. Ma L.-X. One-Pot Facile Fabrication of Graphene-Zinc Oxide Composite and its Enhanced Sensitivity for Simultaneous Electrochemical Detection of Ascorbic Acid, Dopamine and Uric Acid. Sens. Actuators, B. 2016;227:488–496. doi: 10.1016/j.snb.2015.12.073. [DOI] [Google Scholar]
- Mao H. Ji C. Liu M. Sun Y. Liu D. Wu S. Zhang Y. Song X.-M. Hydrophilic Polymer/Polypyrrole/Graphene Oxide Nanosheets with Different Performances in Electrocatalytic Applications to Simultaneously Determine Dopamine and Ascorbic Acid. RSC Adv. 2016;6:111632–111639. doi: 10.1039/C6RA23341D. [DOI] [Google Scholar]
- Muthukumaran P. Sumathi C. Wilson J. Ravi G. Enzymeless Biosensor Based on β-NiS@rGO/Au Nanocomposites for Simultaneous Detection of Ascorbic Acid, Epinephrine and Uric Acid. RSC Adv. 2016;6:96467–96478. doi: 10.1039/C6RA19921F. [DOI] [Google Scholar]
- Vinoth V. Wu J. J. Anandan S. Sensitive Electrochemical Determination of Dopamine and Uric Acid Using AuNPs(EDAS)–rGO Nanocomposites. Anal. Methods. 2016;8:4379–4390. doi: 10.1039/C6AY00335D. [DOI] [Google Scholar]
- Wang X. Gao D. Li M. Li H. Li C. Wu X. Yang B. CVD Graphene as an Electrochemical Sensing Platform for Simultaneous Detection of Biomolecules. Sci. Rep. 2017;7:7044. doi: 10.1038/s41598-017-07646-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhu Q. Bao J. Huo D. Yang M. Hou C. Guo J. Chen M. Fa H. Luo X. Ma Y. 3D Graphene Hydrogel–Gold Nanoparticles Nanocomposite Modified Glassy Carbon Electrode for the Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid. Sens. Actuators, B. 2017;238:1316–1323. doi: 10.1016/j.snb.2016.09.116. [DOI] [Google Scholar]
- Zhu Q. Bao J. Huo D. Yang M. Wu H. Hou C. Zhao Y. Luo X. Fa H. 3DGH-Fc Based Electrochemical Sensor for the Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid. J. Electroanal. Chem. 2017;799:459–467. doi: 10.1016/j.jelechem.2017.07.004. [DOI] [Google Scholar]
- Begum H. Ahmed M. S. Jeon S. New Approach for Porous Chitosan–Graphene Matrix Preparation through Enhanced Amidation for Synergic Detection of Dopamine and Uric Acid. ACS Omega. 2017;2:3043–3054. doi: 10.1021/acsomega.7b00331. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li S.-M. Yang S.-Y. Wang Y.-S. Lien C.-H. Tien H.-W. Hsiao S.-T. Liao W.-H. Tsai H.-P. Chang C.-L. Ma C.-C. M. Hu C.-C. Controllable Synthesis of Nitrogen-Doped Graphene and its Effect on the Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine, and Uric Acid. Carbon. 2013;59:418–429. doi: 10.1016/j.carbon.2013.03.035. [DOI] [Google Scholar]
- Yue H. Y. Huang S. Chang J. Heo C. Yao F. Adhikari S. Gunes F. Liu L. C. Lee T. H. Oh E. S. Li B. Zhang J. J. Huy T. Q. Luan N. V. Lee Y. H. ZnO Nanowire Arrays on 3D Hierachical Graphene Foam: Biomarker Detection of Parkinson's Disease. ACS Nano. 2014;8:1639–1646. doi: 10.1021/nn405961p. [DOI] [PubMed] [Google Scholar]
- Srivastava R. K. Srivastava S. Narayanan T. N. Mahlotra B. D. Vajtai R. Ajayan P. M. Srivastava A. Functionalized Multilayered Graphene Platform for Urea Sensor. ACS Nano. 2012;6:168–175. doi: 10.1021/nn203210s. [DOI] [PubMed] [Google Scholar]
- Dutta D. Chandra S. Swain A. K. Bahadur D. SnO2 Quantum Dots-Reduced Graphene Oxide Composite for Enzyme-Free Ultrasensitive Electrochemical Detection of Urea. Anal. Chem. 2014;86:5914–5921. doi: 10.1021/ac5007365. [DOI] [PubMed] [Google Scholar]
- Wu L. Qu X. Cancer Biomarker Detection: Recent Achievements and Challenges. Chem. Soc. Rev. 2015;44:2963–2997. doi: 10.1039/C4CS00370E. [DOI] [PubMed] [Google Scholar]
- Vargas A. J. Harris C. C. Biomarker Development in the Precision Medicine Era: Lung Cancer as a Case Study. Nat. Rev. Cancer. 2016;16:525–537. doi: 10.1038/nrc.2016.56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jayanthi V. S. P. K. S. A. Das A. B. Saxena U. Recent Advances in Biosensor Development for the Detection of Cancer Biomarkers. Biosens. Bioelectron. 2017;91:15–23. doi: 10.1016/j.bios.2016.12.014. [DOI] [PubMed] [Google Scholar]
- Swierczewska M. Liu G. Lee S. Chen X. High-Sensitivity Nanosensors for Biomarker Detection. Chem. Soc. Rev. 2012;41:2641–2655. doi: 10.1039/C1CS15238F. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Biomarkers Definitions Working Group Atkinson Jr A. J. Colburn W. A. DeGruttola V. G. DeMets D. L. Downing G. J. Hoth D. F. Oates J. A. Peck C. C. Schooley R. T. Biomarkers and surrogate endpoints: preferred definitions and conceptual framework. Clin. Pharmacol. Ther. 2001;69:89–95. doi: 10.1067/mcp.2001.113989. [DOI] [PubMed] [Google Scholar]
- Rusling J. F. Kumar C. V. Gutkind J. S. Patel V. Measurement of Biomarker Proteins for Point-of-Care Early Detection and Monitoring of Cancer. Analyst. 2010;135:2496–2511. doi: 10.1039/C0AN00204F. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hartshorn C. M. Bradbury M. S. Lanza G. M. Nel A. E. Rao J. Wang A. Z. Wiesner U. B. Yang L. Grodzinski P. Nanotechnology Strategies to Advance Outcomes in Clinical Cancer Care. ACS Nano. 2018;12:24–43. doi: 10.1021/acsnano.7b05108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schroeder A. Heller D. A. Winslow M. M. Dahlman J. E. Pratt G. W. Langer R. Jacks T. Anderson D. G. Treating Metastatic Cancer with Nanotechnology. Nat. Rev. Cancer. 2012;12:39–50. doi: 10.1038/nrc3180. [DOI] [PubMed] [Google Scholar]
- Choi Y.-E. Kwak J.-W. Park J. W. Nanotechnology for Early Cancer Detection. Sensors. 2010;10:428–455. doi: 10.3390/s100100428. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pasinszki T. Krebsz M. Tung T. T. Losic D. Carbon Nanomaterial Based Biosensors for Non-Invasive Detection of Cancer and Disease Biomarkers for Clinical Diagnosis. Sensors. 2017;17:1919. doi: 10.3390/s17081919. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yoon H. J. Kim T. H. Zhang Z. Azizi E. Pham T. M. Paoletti C. Lin J. Ramnath N. Wicha M. S. Hayes D. F. Simeone D. M. Nagrath S. Sensitive Capture of Circulating Tumour Cells by Functionalized Graphene Oxide Nanosheets. Nat. Nanotechnol. 2013;8:735–741. doi: 10.1038/nnano.2013.194. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yoon H. J. Shanker A. Wang Y. Kozminsky M. Jin Q. Palanisamy N. Burness M. L. Azizi E. Simeone D. M. Wicha M. S. Kim J. Nagrath S. Tunable Thermal-Sensitive Polymer-Graphene Oxide Composite for Efficient Capture and Release of Viable Circulating Tumor Cells. Adv. Mater. 2016;28:4891–4897. doi: 10.1002/adma.201600658. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ali M. A. Singh C. Srivastava S. Admane P. Agrawal V. V. Sumana G. John R. Panda A. Dong L. Malhotra B. D. Graphene Oxide–Metal Nanocomposites for Cancer Biomarker Detection. RSC Adv. 2017;7:35982–35991. doi: 10.1039/C7RA05491B. [DOI] [Google Scholar]
- Zhu Q. Liu H. Zhang J. Wu K. Deng A. Li J. Ultrasensitive QDs Based Electrochemiluminescent Immunosensor for Detecting Ractopamine Using AuNPs and Au Nanoparticles@PDDA-Graphene as Amplifier. Sens. Actuators, B. 2017;243:121–129. doi: 10.1016/j.snb.2016.11.135. [DOI] [Google Scholar]
- Kumar V. Srivastava S. Umrao S. Kumar R. Nath G. Sumana G. Saxena P. S. Srivastava A. Nanostructured Palladium-Reduced Graphene Oxide Platform for High Sensitive, Label Free Detection of a Cancer Biomarker. RSC Adv. 2014;4:2267–2273. doi: 10.1039/C3RA41986J. [DOI] [Google Scholar]
- Chen X. Jia X. Han J. Ma J. Ma Z. Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites. Biosens. Bioelectron. 2013;50:356–361. doi: 10.1016/j.bios.2013.06.054. [DOI] [PubMed] [Google Scholar]
- Lin D. Wu J. Wang M. Yan F. Ju H. Triple Signal Amplification of Graphene Film, Polybead Carried Gold Nanoparticles as Tracing Tag and Silver Deposition for Ultrasensitive Electrochemical Immunosensing. Anal. Chem. 2012;84:3662–3668. doi: 10.1021/ac3001435. [DOI] [PubMed] [Google Scholar]
- Jin B. Wang P. Mao H. Hu B. Zhang H. Cheng Z. Wu Z. Bian X. Jia C. Jing F. Jin Q. Zhao J. Multi-Nanomaterial Electrochemical Biosensor Based on Label-Free Graphene for Detecting Cancer Biomarkers. Biosens. Bioelectron. 2014;55:464–469. doi: 10.1016/j.bios.2013.12.025. [DOI] [PubMed] [Google Scholar]
- Jia X. Liu Z. Liu N. Ma Z. A Label-Free Immunosensor Based on Graphene Nanocomposites for Simultaneous Multiplexed Electrochemical Determination of Tumor Markers. Biosens. Bioelectron. 2014;53:160–166. doi: 10.1016/j.bios.2013.09.050. [DOI] [PubMed] [Google Scholar]
- Song C. Xie G. Wang L. Liu L. Tian G. Xiang H. DNA-Based Hybridization Chain Reaction for an Ultrasensitive Cancer Marker EBNA-1 Electrochemical Immunosensor. Biosens. Bioelectron. 2014;58:68–74. doi: 10.1016/j.bios.2014.02.031. [DOI] [PubMed] [Google Scholar]
- Teixeira S. Burwell G. Castaing A. Gonzalez D. Conlan R. S. Guy O. J. Epitaxial Graphene Immunosensor for Human Chorionic Gonadotropin. Sens. Actuators, B. 2014;190:723–729. doi: 10.1016/j.snb.2013.09.019. [DOI] [Google Scholar]
- Jang H. D. Kim S. K. Chang H. Choi J.-W. 3D Label-Free Prostate Specific Antigen (PSA) Immunosensor Based on Graphene–Gold Composites. Biosens. Bioelectron. 2015;63:546–551. doi: 10.1016/j.bios.2014.08.008. [DOI] [PubMed] [Google Scholar]
- Ali M. A. Mondal K. Jiao Y. Oren S. Xu Z. Sharma A. Dong L. Microfluidic Immuno-Biochip for Detection of Breast Cancer Biomarkers Using Hierarchical Composite of Porous Graphene and Titanium Dioxide Nanofibers. ACS Appl. Mater. Interfaces. 2016;8:20570–20582. doi: 10.1021/acsami.6b05648. [DOI] [PubMed] [Google Scholar]
- Kumar S. Sharma J. G. Maji S. Malhotra B. D. Nanostructured Zirconia Decorated Reduced Graphene Oxide Based Efficient Biosensing Platform for Non-Invasive Oral Cancer Detection. Biosens. Bioelectron. 2016;78:497–504. doi: 10.1016/j.bios.2015.11.084. [DOI] [PubMed] [Google Scholar]
- Feng T. Qiao X. Wang H. Sun Z. Qi Y. Hong C. An Electrochemical Immunosensor for Simultaneous Point-of-Care Cancer Markers Based on the Host–Guest Inclusion of β-Cyclodextrin–Graphene Oxide. J. Mater. Chem. B. 2016;4:990–996. doi: 10.1039/C5TB02480C. [DOI] [PubMed] [Google Scholar]
- Wang G. Li Y. Liu J. Yuan Y. Shen Z. Mei X. Ultrasensitive Multiplexed Immunoassay of Autophagic Biomarkers Based on Au/rGO and Au Nanocages Amplifying Electrochemical Signal. Sci. Rep. 2017;7:2442. doi: 10.1038/s41598-017-02766-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pal M. Khan R. Graphene Oxide Layer Decorated Gold Nanoparticles Based Immunosensor for the Detection Of Prostate Cancer Risk Factor. Anal. Biochem. 2017;536:51–58. doi: 10.1016/j.ab.2017.08.001. [DOI] [PubMed] [Google Scholar]
- Hao L. Liu L. Meng X. Cui H. Wang Z. Electrochemical Analysis of Ki67 Protein As Pancreatic Cancer Biomarker Based on Graphene-Polydopamine Nanocomposite. Int. J. Electrochem. Sci. 2017;12:3040–3049. doi: 10.20964/2017.04.66. [DOI] [Google Scholar]
- Wang H. Zhang Y. Wang Y. Ma H. Du B. Wei Q. Facile Synthesis of Cuprous Oxide Nanowires Decorated Graphene Oxide Nanosheets Nanocomposites and its Application in Label-Free Electrochemical Immunosensor. Biosens. Bioelectron. 2017;87:745–751. doi: 10.1016/j.bios.2016.09.014. [DOI] [PubMed] [Google Scholar]
- Yang Z. Lan Q. Li J. Wu J. Tang Y. Hu X. Efficient Streptavidin-Functionalized Nitrogen-Doped Graphene for the Development of Highly Sensitive Electrochemical Immunosensor. Biosens. Bioelectron. 2017;89:312–318. doi: 10.1016/j.bios.2016.09.026. [DOI] [PubMed] [Google Scholar]
- Yang Y. Liu Q. Liu Y. Cui J. Liu H. Wang P. Li Y. Chen L. Zhao Z. Dong Y. A Novel Label-Free Electrochemical Immunosensor Based on Functionalized Nitrogen-Doped Graphene Quantum Dots for Carcinoembryonic Antigen Detection. Biosens. Bioelectron. 2017;90:31–38. doi: 10.1016/j.bios.2016.11.029. [DOI] [PubMed] [Google Scholar]
- Tuteja S. K. Duffield T. Neethirajan S. Graphene-Based Multiplexed Disposable Electrochemical Biosensor for Rapid on-Farm Monitoring of NEFA and βHBA Dairy Biomarkers. J. Mater. Chem. B. 2017;5:6930–6940. doi: 10.1039/C7TB01382E. [DOI] [PubMed] [Google Scholar]
- Pan L.-H. Kuo S.-H. Lin T.-Y. Lin C.-W. Fang P.-Y. Yang H.-W. An Electrochemical Biosensor to Simultaneously Detect VEGF and PSA for Early Prostate Cancer Diagnosis Based on Graphene Oxide/ssDNA/PLLA Nanoparticles. Biosens. Bioelectron. 2017;89:598–605. doi: 10.1016/j.bios.2016.01.077. [DOI] [PubMed] [Google Scholar]
- Feng J. Li Y. Li M. Li F. Han J. Dong Y. Chen Z. Wang P. Liu H. Wei Q. A Novel Sandwich-Type Electrochemical Immunosensor for PSA Detection Based on PtCu Bimetallic Hybrid (2D/2D) rGO/g-C3N4. Biosens. Bioelectron. 2017;91:441–448. doi: 10.1016/j.bios.2016.12.070. [DOI] [PubMed] [Google Scholar]
- Saeed A. A. Sánchez J. L. A. O'Sullivan C. K. Abbas M. N. DNA Biosensors Based on Gold Nanoparticles-Modified Graphene Oxide for the Detection of Breast Cancer Biomarkers for Early Diagnosis. Bioelectrochemistry. 2017;118:91–99. doi: 10.1016/j.bioelechem.2017.07.002. [DOI] [PubMed] [Google Scholar]
- Ren X. Ma H. Zhang T. Zhang Y. Yan T. Du B. Wei Q. Sulfur-Doped Graphene-Based Immunological Biosensing Platform for Multianalysis of Cancer Biomarkers. ACS Appl. Mater. Interfaces. 2017;9:37637–37644. doi: 10.1021/acsami.7b13416. [DOI] [PubMed] [Google Scholar]
- Lee S. X. Lim H. N. Ibrahim I. Jamil A. Pandikumar A. Huang N. M. Horseradish Peroxidase-Labeled Silver/Reduced Graphene Oxide Thin Film-Modified Screen-Printed Electrode for Detection of Carcinoembryonic Antigen. Biosens. Bioelectron. 2017;89:673–680. doi: 10.1016/j.bios.2015.12.030. [DOI] [PubMed] [Google Scholar]
- Li M. Wang P. Li F. Chu Q. Li Y. Dong Y. An Ultrasensitive Sandwich-Type Electrochemical Immunosensor Based on the Signal Amplification Strategy of Mesoporous Core–Shell Pd@Pt Nanoparticles/Amino Group Functionalized Graphene Nanocomposite. Biosens. Bioelectron. 2017;87:752–759. doi: 10.1016/j.bios.2016.08.076. [DOI] [PubMed] [Google Scholar]
- Shahzad F. Zaidi S. A. Koo C. M. Highly Sensitive Electrochemical Sensor Based on Environmentally Friendly Biomass-Derived Sulfur-Doped Graphene For Cancer Biomarker Detection. Sens. Actuators, B. 2017;241:716–724. doi: 10.1016/j.snb.2016.10.144. [DOI] [Google Scholar]
- Sharafeldin M. Bishop G. W. Bhakta S. El-Sawy A. Suib S. L. Rusling J. F. Fe3O4 Nanoparticles on Graphene Oxide Sheets for Isolation and Ultrasensitive Amperometric Detection of Cancer Biomarker Proteins. Biosens. Bioelectron. 2017;91:359–366. doi: 10.1016/j.bios.2016.12.052. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Huang J.-Y. Zhao L. Lei W. Wen W. Wang Y.-J. Bao T. Xiong H.-Y. Zhang X.-H. Wang S.-F. A High-Sensitivity Electrochemical Aptasensor of Carcinoembryonic Antigen Based on Graphene Quantum Dots-Ionic Liquid-Nafion Nanomatrix and DNAzyme-Assisted Signal Amplification Strategy. Biosens. Bioelectron. 2018;99:28–33. doi: 10.1016/j.bios.2017.07.036. [DOI] [PubMed] [Google Scholar]
- Chen M. Wang Y. Su H. Mao L. Jiang X. Zhang T. Dai X. Three-Dimensional Electrochemical DNA Biosensor Based on 3D Graphene-Ag Nanoparticles for Sensitive Detection of CYFRA21-1 in Non-Small Cell Lung Cancer. Sens. Actuators, B. 2018;255:2910–2918. doi: 10.1016/j.snb.2017.09.111. [DOI] [Google Scholar]
- Cao J.-T. Yang J.-J. Zhao L.-Z. Wang Y.-L. Wang H. Liu Y.-M. Ma S.-H. Graphene Oxide@Gold Nanorods-Based Multiple-Assisted Electrochemiluminescence Signal Amplification Strategy for Sensitive Detection of Prostate Specific Antigen. Biosens. Bioelectron. 2018;99:92–98. doi: 10.1016/j.bios.2017.07.050. [DOI] [PubMed] [Google Scholar]
- Wang R. Feng J.-J. Xue Y. Wu L. Wang A.-J. A Label-Free Electrochemical Immunosensor Based on AgPt Nanorings Supported on Reduced Graphene Oxide for Ultrasensitive Analysis of Tumor Marker. Sens. Actuators, B. 2018;254:1174–1181. doi: 10.1016/j.snb.2017.08.009. [DOI] [Google Scholar]
- Wang J. Wang X. Tang H. Gao Z. He S. Li J. Han S. Ultrasensitive Electrochemical Detection of Tumor Cells Based on Multiple Layer CDS Quantum Dots-Functionalized Polystyrene Microspheres and Graphene Oxide–Polyaniline Composite. Biosens. Bioelectron. 2018;100:1–7. doi: 10.1016/j.bios.2017.07.077. [DOI] [PubMed] [Google Scholar]
- Singh V. K. Kumar S. Pandey S. K. Srivastava S. Mishra M. Gupta G. Malhotra B. D. Tiwari R. S. Srivastava A. Fabrication of Sensitive Bioelectrode Based on Atomically Thin CVD Grown Graphene for Cancer Biomarker Detection. Biosens. Bioelectron. 2018;105:173–181. doi: 10.1016/j.bios.2018.01.014. [DOI] [PubMed] [Google Scholar]
- Mazloum-Ardakani M. Barazesh B. Khoshroo A. Moshtaghiun M. Sheikhha M. H. A New Composite Consisting of Electrosynthesized Conducting Polymers, Graphene Sheets and Biosynthesized Gold Nanoparticles for Biosensing Acute Lymphoblastic Leukemia. Bioelectrochemistry. 2018;121:38–45. doi: 10.1016/j.bioelechem.2017.12.010. [DOI] [PubMed] [Google Scholar]
- Zhang G. Liu Z. Fan L. Guo Y. Electrochemical Prostate Specific Antigen Aptasensor Based on Hemin Functionalized Graphene-Conjugated Palladium Nanocomposites. Microchim. Acta. 2018;185:159. doi: 10.1007/s00604-018-2686-9. [DOI] [PubMed] [Google Scholar]
- Rauf S. Mishra G. K. Azhar J. Mishra R. K. Goud K. Y. Nawaz M. A. H. Marty J. L. Hayat A. Carboxylic Group Riched Graphene Oxide Based Disposable Electrochemical Immunosensor for Cancer Biomarker Detection. Anal. Biochem. 2018;545:13–19. doi: 10.1016/j.ab.2018.01.007. [DOI] [PubMed] [Google Scholar]
- Shahrokhian S. Salimian R. Ultrasensitive Detection of Cancer Biomarkers Using Conducting Polymer/Electrochemically Reduced Graphene Oxide-Based Biosensor: Application Toward BRCA1 Sensing. Sens. Actuators, B. 2018;266:160–169. doi: 10.1016/j.snb.2018.03.120. [DOI] [Google Scholar]
- Wu L. Ji H. Guan Y. Ran X. Ren J. Qu X. A Graphene-Based Chemical Nose/Tongue Approach for the Identification of Normal, Cancerous and Circulating Tumor Cells. NPG Asia Mater. 2017;9:e356. doi: 10.1038/am.2017.11. [DOI] [Google Scholar]
- Whitesides G. M. The Origins and the Future of Microfluidics. Nature. 2006;442:368–373. doi: 10.1038/nature05058. [DOI] [PubMed] [Google Scholar]
- de Oliveira R. A. G. Materon E. M. Melendez M. E. Carvalho A. L. Faria R. C. Disposable Microfluidic Immunoarray Device for Sensitive Breast Cancer Biomarker Detection. ACS Appl. Mater. Interfaces. 2017;9:27433–27440. doi: 10.1021/acsami.7b03350. [DOI] [PubMed] [Google Scholar]
- Cate D. M. Adkins J. A. Mettakoonpitak J. Henry C. S. Recent Developments in Paper-Based Microfluidic Devices. Anal. Chem. 2015;87:19–41. doi: 10.1021/ac503968p. [DOI] [PubMed] [Google Scholar]
- Wu Y. Xue P. Kang Y. Hui K. M. Paper-Based Microfluidic Electrochemical Immunodevice Integrated with Nanobioprobes onto Graphene Film for Ultrasensitive Multiplexed Detection of Cancer Biomarkers. Anal. Chem. 2013;85:8661–8668. doi: 10.1021/ac401445a. [DOI] [PubMed] [Google Scholar]
- Singh N. Ali M. A. Rai P. Sharma A. Malhotra B. D. John R. Microporous Nanocomposite Enabled Microfluidic Biochip for Cardiac Biomarker Detection. ACS Appl. Mater. Interfaces. 2017;9:33576–33588. doi: 10.1021/acsami.7b07590. [DOI] [PubMed] [Google Scholar]
- Dye C. After 2015: Infectious Diseases in a New Era of Health and Development. Philos. Trans. R. Soc., B. 2014;369:20130426. doi: 10.1098/rstb.2013.0426. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Paulitz T. C. Bélanger R. R. Biologicalcontrol in Greenhousesystems. Annu. Rev. Phytopathol. 2001;39:103–133. doi: 10.1146/annurev.phyto.39.1.103. [DOI] [PubMed] [Google Scholar]
- Alocilja E. C. Radke S. M. Market Analysis of Biosensors for Food Safety. Biosens. Bioelectron. 2003;18:841–846. doi: 10.1016/S0956-5663(03)00009-5. [DOI] [PubMed] [Google Scholar]
- Khater M. de la Escosura-Muñiz A. Merkoçi A. Biosensors for Plant Pathogen Detection. Biosens. Bioelectron. 2017;93:72–86. doi: 10.1016/j.bios.2016.09.091. [DOI] [PubMed] [Google Scholar]
- dos Santos M. B. Agusil J. P. Prieto-Simón B. Sporer C. Teixeira V. Samitier J. Highly Sensitive Detection of Pathogen Escherichia coli O157:H7 by Electrochemical Impedance Spectroscopy. Biosens. Bioelectron. 2013;45:174–180. doi: 10.1016/j.bios.2013.01.009. [DOI] [PubMed] [Google Scholar]
- Yang L. Bashir R. Electrical/Electrochemical Impedance for Rapid Detection of Foodborne Pathogenic Bacteria. Biotechnol. Adv. 2008;26:135–150. doi: 10.1016/j.biotechadv.2007.10.003. [DOI] [PubMed] [Google Scholar]
- Amiri M. Bezaatpour A. Jafari H. Boukherroub R. Szunerits S. Electrochemical Methodologies for the Detection of Pathogens. ACS Sens. 2018;3:1069–1086. doi: 10.1021/acssensors.8b00239. [DOI] [PubMed] [Google Scholar]
- Tiwari I. Singh M. Pandey C. M. Sumana G. Electrochemical Genosensor Based on Graphene Oxide Modified Iron Oxide–Chitosan Hybrid Nanocomposite for Pathogen Detection. Sens. Actuators, B. 2016;206:276–283. doi: 10.1016/j.snb.2014.09.056. [DOI] [Google Scholar]
- Tiwari I. Singh M. Pandey C. M. Sumana G. Electrochemical Detection of a Pathogenic Escherichia coli Specific DNA Sequence Based on a Graphene Oxide–Chitosan Composite Decorated with Nickel Ferrite Nanoparticles. RSC Adv. 2015;5:67115–67124. doi: 10.1039/C5RA07298K. [DOI] [Google Scholar]
- Zhou Q. Li G. Zhang Y. Zhu M. Wan Y. Shen Y. Highly Selective and Sensitive Electrochemical Immunoassay of Cry1C Using Nanobody and π–π Stacked Graphene Oxide/Thionine Assembly. Anal. Chem. 2016;88:9830–9836. doi: 10.1021/acs.analchem.6b02945. [DOI] [PubMed] [Google Scholar]
- Jia F. Duan N. Wu S. Ma X. Xia Y. Wang Z. Wei X. Impedimetric Aptasensor for Staphylococcus aureus based on Nanocomposite Prepared from Reduced Graphene Oxide and Gold Nanoparticles. Microchim. Acta. 2014;181:967–974. doi: 10.1007/s00604-014-1195-8. [DOI] [Google Scholar]
- Pandey C. M. Tiwari I. Singh V. N. Sood K. N. Sumana G. Malhotra B. D. Highly Sensitive Electrochemical Immunosensor Based on Graphene-Wrapped Copper Oxide-Cysteine Hierarchical Structure for Detection of Pathogenic Bacteria. Sens. Actuators, B. 2017;238:1060–1069. doi: 10.1016/j.snb.2016.07.121. [DOI] [Google Scholar]
- Pandey A. Gurbuz Y. Ozguz V. Niazi J. H. Qureshi A. Graphene-Interfaced Electrical Biosensor for Label-Free and Sensitive Detection of Foodborne Pathogenic E. coli O157:H7. Biosens. Bioelectron. 2017;91:225–231. doi: 10.1016/j.bios.2016.12.041. [DOI] [PubMed] [Google Scholar]
- Ye W. Guo J. Bao X. Chen T. Weng W. Chen S. Yang M. Rapid and Sensitive Detection of Bacteria Response to Antibiotics Using Nanoporous Membrane and Graphene Quantum Dot (GQDs)-Based Electrochemical Biosensors. Materials. 2017;10:603. doi: 10.3390/ma10060603. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kaur H. Shorie M. Sharma M. Ganguli A. K. Sabherwal P. Bridged Rebar Graphene Functionalized Aptasensor for Pathogenic E. coli O78:K80:H11 Detection. Biosens. Bioelectron. 2017;98:486–493. doi: 10.1016/j.bios.2017.07.004. [DOI] [PubMed] [Google Scholar]
- Dinshaw I. J. Muniandy S. Teh S. J. Ibrahim F. Leo B. F. Thong K. L. Development of an Aptasensor Using Reduced Graphene Oxide Chitosan Complex to Detect Salmonella. J. Electroanal. Chem. 2017;806:88–96. doi: 10.1016/j.jelechem.2017.10.054. [DOI] [Google Scholar]
- Fei J. Dou W. Zhao G. Amperometric Immunoassay for the Detection of Salmonella pullorum Using a Screen - Printed Carbon Electrode Modified with Gold Nanoparticle-Coated Reduced Graphene Oxide and Immunomagnetic Beads. Microchim. Acta. 2016;183:757–764. doi: 10.1007/s00604-015-1721-3. [DOI] [Google Scholar]
- Muniandy S. Dinshaw I. J. Teh S. J. Lai C. W. Ibrahim F. Thong K. L. Leo B. F. Graphene-Based Label-Free Electrochemical Aptasensor for Rapid and Sensitive Detection of Foodborne Pathogen. Anal. Bioanal. Chem. 2017;409:6893–6905. doi: 10.1007/s00216-017-0654-6. [DOI] [PubMed] [Google Scholar]
- Xu S. Zhang Y. Dong K. Wen J. Zheng C. Zhao S. Electrochemical DNA Biosensor Based on Graphene Oxide-Chitosan Hybrid Nanocomposites for Detection of Escherichia coli O157: H7. Int. J. Electrochem. Sci. 2017;12:3443–3458. doi: 10.20964/2017.04.16. [DOI] [Google Scholar]
- Kumar N. Rosy S. Goyal R. N. Gold-Palladium Nanoparticles Aided Electrochemically Reduced Graphene Oxide Sensor for the Simultaneous Estimation of Lomefloxacin and Amoxicillin. Sens. Actuators, B. 2017;243:658–668. doi: 10.1016/j.snb.2016.12.025. [DOI] [Google Scholar]
- Chen S. Frank Cheng Y. Voordouw G. Three-Dimensional Graphene Nanosheet Doped with Gold Nanoparticles as Electrochemical DNA Biosensor for Bacterial Detection. Sens. Actuators, B. 2018;262:860–868. doi: 10.1016/j.snb.2018.02.093. [DOI] [Google Scholar]
- Shukla S. Haldorai Y. Bajpai V. K. Rengaraj A. Hwang S. K. Song X. Kim M. Huh Y. S. Han Y.-K. Electrochemical Coupled Immunosensing Platform Based on Graphene Oxide/Gold Nanocomposite for Sensitive Detection of Cronobacter Sakazakii in Powdered Infant Formula. Biosens. Bioelectron. 2018;109:139–149. doi: 10.1016/j.bios.2018.03.010. [DOI] [PubMed] [Google Scholar]
- Jijie R. Kahlouche K. Barras A. Yamakawa N. Bouckaert J. Gharbi T. Szunerits S. Boukherroub R. Reduced Graphene Oxide/Polyethylenimine Based Immunosensor for the Selective and Sensitive Electrochemical Detection of Uropathogenic Escherichia coli. Sens. Actuators, B. 2018;260:255–263. doi: 10.1016/j.snb.2017.12.169. [DOI] [Google Scholar]
- Krittayavathananon A. Sawangphruk M. Impedimetric Sensor of ss-HSDNA/Reduced Graphene Oxide Aerogel Electrode toward Aflatoxin B1 Detection: Effects of Redox Mediator Charges and Hydrodynamic Diffusion. Anal. Chem. 2017;89:13283–13289. doi: 10.1021/acs.analchem.7b03329. [DOI] [PubMed] [Google Scholar]
- Srivastava S. Kumar V. Ali M. A. Solanki P. R. Srivastava A. Sumana G. Saxena P. S. Joshi A. G. Malhotra B. D. Electrophoretically Deposited Reduced Graphene Oxide Platform for Food Toxin Detection. Nanoscale. 2013;5:3043–3051. doi: 10.1039/C3NR32242D. [DOI] [PubMed] [Google Scholar]
- Srivastava S. Abraham S. Singh C. Ali M. A. Srivastava A. Sumana G. Malhotra B. D. Protein Conjugated Carboxylated Gold@Reduced Graphene Oxide For Aflatoxin B1 Detection. RSC Adv. 2015;5:5406–5414. doi: 10.1039/C4RA12713G. [DOI] [Google Scholar]
- Wang D. Hu W. Xiong Y. Xu Y. Ming Li C. Multifunctionalized Reduced Graphene Oxide-Doped Polypyrrole/Pyrrolepropylic Acid Nanocomposite Impedimetric Immunosensor to Ultra-Sensitively Detect Small Molecular Aflatoxin B1. Biosens. Bioelectron. 2015;63:185–189. doi: 10.1016/j.bios.2014.06.070. [DOI] [PubMed] [Google Scholar]
- Srivastava S. Kumar V. Arora K. Singh C. Ali M. A. Puri N. K. Malhotra B. D. Antibody Conjugated Metal Nanoparticle Decorated Graphene Sheets for a Mycotoxin Sensor. RSC Adv. 2016;6:56518–56526. doi: 10.1039/C6RA04469G. [DOI] [Google Scholar]
- Sun A.-L. Zhang Y.-F. Sun G.-P. Wang X.-N. Tang D. Homogeneous Electrochemical Detection of Ochratoxin A in Foodstuff Using Aptamer–Graphene Oxide Nanosheets and Dnase I-Based Target Recycling Reaction. Biosens. Bioelectron. 2017;89:659–665. doi: 10.1016/j.bios.2015.12.032. [DOI] [PubMed] [Google Scholar]
- Eissa S. Zourob M. In vitro Selection of DNA Aptamers Targeting β-Lactoglobulin and Their Integration in Graphene-Based Biosensor for the Detection of Milk Allergen. Biosens. Bioelectron. 2017;91:169–174. doi: 10.1016/j.bios.2016.12.020. [DOI] [PubMed] [Google Scholar]
- Zhu L. Xu L. Huang B. Jia N. Tan L. Yao S. Simultaneous Determination of Cd(II) and Pb(II) Using Square Wave Anodic Stripping Voltammetry at a Gold Nanoparticle-Graphene-Cysteine Composite Modified Bismuth Film Electrode. Electrochim. Acta. 2014;115:471–477. doi: 10.1016/j.electacta.2013.10.209. [DOI] [Google Scholar]
- Gong X. Bi Y. Zhao Y. Liu G. Teoh W. Y. Graphene Oxide-Based Electrochemical Sensor: A Platform for Ultrasensitive Detection of Heavy Metal Ions. RSC Adv. 2014;4:24653–24657. doi: 10.1039/C4RA02247E. [DOI] [Google Scholar]
- Zhu H. Xu Y. Liu A. Kong N. Shan F. Yang W. Barrow C. J. Liu J. Graphene Nanodots-Encaged Porous Gold Electrode Fabricated via Ion Beam Sputtering Deposition for Electrochemical Analysis of Heavy Metal Ions. Sens. Actuators, B. 2015;206:592–600. doi: 10.1016/j.snb.2014.10.009. [DOI] [Google Scholar]
- Tang S. Tong P. You X. Lu W. Chen J. Li G. Zhang L. Label free Electrochemical Sensor for Pb2+ Based on Graphene Oxide Mediated Deposition of Silver Nanoparticles. Electrochim. Acta. 2016;187:286–292. doi: 10.1016/j.electacta.2015.11.040. [DOI] [Google Scholar]
- Xue S. Jing P. Xu W. Hemin on Graphene Nanosheets Functionalized with Flower-Like MnO2 and Hollow AuPd for the Electrochemical Sensing Lead Ion Based on the Specific DNAzyme. Biosens. Bioelectron. 2016;86:958–965. doi: 10.1016/j.bios.2016.07.111. [DOI] [PubMed] [Google Scholar]
- Zhang Z. Fu X. Li K. Liu R. Peng D. He L. Wang M. Zhang H. Zhou L. One-Step Fabrication of Electrochemical Biosensor Based on DNA-Modified Three-Dimensional Reduced Graphene Oxide and Chitosan Nanocomposite for Highly Sensitive Detection of Hg(II) Sens. Actuators, B. 2016;225:453–462. doi: 10.1016/j.snb.2015.11.091. [DOI] [Google Scholar]
- Wang N. Lin M. Dai H. Ma H. Functionalized Gold Nanoparticles/Reduced Graphene Oxide Nanocomposites for Ultrasensitive Electrochemical Sensing Of Mercury Ions Based on Thymine–Mercury–Thymine Structure. Biosens. Bioelectron. 2016;79:320–326. doi: 10.1016/j.bios.2015.12.056. [DOI] [PubMed] [Google Scholar]
- Priya T. Dhanalakshmi N. Thinakaran N. Electrochemical Behavior of Pb (II) on a Heparin Modified Chitosan/Graphene Nanocomposite Film Coated Glassy Carbon Electrode and its Sensitive Detection. Int. J. Biol. Macromol. 2017;104:672–680. doi: 10.1016/j.ijbiomac.2017.06.082. [DOI] [PubMed] [Google Scholar]
- Zhu Y. Pan D. Hu X. Han H. Lin M. Wang C. An Electrochemical Sensor Based on Reduced Graphene Oxide/Gold Nanoparticles Modified Electrode for Determination of Iron in Coastal Waters. Sens. Actuators, B. 2017;243:1–7. doi: 10.1016/j.snb.2016.11.108. [DOI] [Google Scholar]
- Yang L. Huang N. Huang L. Liu M. Li H. Zhang Y. Yao S. An Electrochemical Sensor for Highly Sensitive Detection of Copper Ions Based on a New Molecular Probe Pi-A Decorated on Graphene. Anal. Methods. 2017;9:618–624. doi: 10.1039/C6AY03006H. [DOI] [Google Scholar]
- Sadak O. Sundramoorthy A. K. Gunasekaran S. Highly Selective Colorimetric and Electrochemical Sensing of Iron (III) Using Nile Red Functionalized Graphene Film. Biosens. Bioelectron. 2017;89:430–436. doi: 10.1016/j.bios.2016.04.073. [DOI] [PubMed] [Google Scholar]
- Guo Z. Li D.-d. Luo X.-k. Li Y.-h. Zhao Q.-N. Li M.-m. Zhao Y.-t. Sun T.-s. Ma C. Simultaneous Determination of Trace Cd(II), Pb(II) and Cu(II) by Differential Pulse Anodic Stripping Voltammetry Using a Reduced Graphene Oxide-Chitosan/Poly-L-Lysine Nanocomposite Modified Glassy Carbon Electrode. J. Colloid Interface Sci. 2017;490:11–22. doi: 10.1016/j.jcis.2016.11.006. [DOI] [PubMed] [Google Scholar]
- Zhang Y. Zeng G. M. Tang L. Chen J. Zhu Y. He X. X. He Y. Electrochemical Sensor Based on Electrodeposited Graphene-Au Modified Electrode and NanoAu Carrier Amplified Signal Strategy for Attomolar Mercury Detection. Anal. Chem. 2015;87:989–996. doi: 10.1021/ac503472p. [DOI] [PubMed] [Google Scholar]
- Gumpu M. B. Veerapandian M. Krishnan U. M. Rayappan J. B. B. Simultaneous Electrochemical Detection of Cd(II), Pb(II), As(III) and Hg(II) Ions Using Ruthenium(II)-Textured Graphene Oxide Nanocomposite. Talanta. 2017;162:574–582. doi: 10.1016/j.talanta.2016.10.076. [DOI] [PubMed] [Google Scholar]
- Yiwei X. Wen Z. Xiaowei H. Jiyong S. Xiaobo Z. Yanxiao L. Xueping C. Tahir H. E. Zhihua L. A Self-Assembled L-Cysteine and Electrodeposited Gold Nanoparticles-reduced Graphene Oxide Modified Electrode for Adsorptive Stripping Determination of Copper. Electroanalysis. 2018;30:194–203. doi: 10.1002/elan.201700637. [DOI] [Google Scholar]
- Zhou S.-F. Han X.-J. Fan H.-L. Huang J. Liu Y.-Q. Enhanced Electrochemical Performance for Sensing Pb(II) Based on Graphene Oxide Incorporated Mesoporous MnFe2O4 Nanocomposites. J. Alloys Compd. 2018;747:447–454. doi: 10.1016/j.jallcom.2018.03.037. [DOI] [Google Scholar]
- Lu L. Zhou L. Chen J. Yan F. Liu J. Dong X. Xi F. Chen P. Nanochannel-Confined Graphene Quantum Dots for Ultrasensitive Electrochemical Analysis of Complex Samples. ACS Nano. 2018;12:12673–12681. doi: 10.1021/acsnano.8b07564. [DOI] [PubMed] [Google Scholar]
- Rotariu L. Lagarde F. Jaffrezic-Renault N. Bala C. Electrochemical Biosensors for Fast Detection of Food Contaminants–Trends and Perspective. TrAC, Trends Anal. Chem. 2016;79:80–87. doi: 10.1016/j.trac.2015.12.017. [DOI] [Google Scholar]
- Silva N. F. D. Magalhães J. M. C. S. Freire C. Delerue-Matos C. Electrochemical Biosensors for Salmonella: State of the Art and Challenges in Food Safety Assessment. Biosens. Bioelectron. 2018;99:667–682. doi: 10.1016/j.bios.2017.08.019. [DOI] [PubMed] [Google Scholar]
- Vasilescu A. Marty J.-L. Electrochemical Aptasensors for the Assessment of Food Quality and Safety. TrAC, Trends Anal. Chem. 2016;79:60–70. doi: 10.1016/j.trac.2015.11.024. [DOI] [Google Scholar]
- Huang J. Gao X. Jia J. Kim J.-K. Li Z. Graphene Oxide-Based Amplified Fluorescent Biosensor for Hg2+ Detection through Hybridization Chain Reactions. Anal. Chem. 2014;86:3209–3215. doi: 10.1021/ac500192r. [DOI] [PubMed] [Google Scholar]
- Lan L. Yao Y. Ping J. Ying Y. Recent Progress in Nanomaterial-Based Optical Aptamer Assay for the Detection of Food Chemical Contaminants. ACS Appl. Mater. Interfaces. 2017;9:23287–23301. doi: 10.1021/acsami.7b03937. [DOI] [PubMed] [Google Scholar]
- Kaur N. Bharti A. Batra S. Rana S. Rana S. Bhalla A. Prabhakar N. An electrochemical aptasensor based on graphene doped chitosan nanocomposites for determination of ochratoxin A. Microchem. J. 2019;144:102–109. doi: 10.1016/j.microc.2018.08.064. [DOI] [Google Scholar]
- Jiang L. Qian J. Yang X. Yan Y. Liu Q. Wang K. Wang K. Amplified Impedimetric Aptasensor Based on Gold Nanoparticles Covalently Bound Graphene Sheet for the Picomolar Detection of Ochratoxin A. Anal. Chim. Acta. 2014;806:128–135. doi: 10.1016/j.aca.2013.11.003. [DOI] [PubMed] [Google Scholar]
- Aragay G. Pons J. Merkoçi A. Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal Detection. Chem. Rev. 2011;111:3433–3458. doi: 10.1021/cr100383r. [DOI] [PubMed] [Google Scholar]
- Fu F. Wang Q. Removal of Heavy Metal Ions from Wastewaters: A Review. J. Environ. Manage. 2011;92:407–418. doi: 10.1016/j.jenvman.2010.11.011. [DOI] [PubMed] [Google Scholar]
- Bansod B. Kumar T. Thakur R. Rana S. Singh I. A Review on Various Electrochemical Techniques for Heavy Metal Ions Detection with Different Sensing Platforms. Biosens. Bioelectron. 2017;94:443–455. doi: 10.1016/j.bios.2017.03.031. [DOI] [PubMed] [Google Scholar]
- Gong X. Liu G. Li Y. Yu D. Y. W. Teoh W. Y. Functionalized-Graphene Composites: Fabrication and Applications in Sustainable Energy and Environment. Chem. Mater. 2016;28:8082–8118. doi: 10.1021/acs.chemmater.6b01447. [DOI] [Google Scholar]
- Vilela D. Parmar J. Zeng Y. Zhao Y. Sánchez S. Graphene-Based Microbots for Toxic Heavy Metal Removal and Recovery from Water. Nano Lett. 2016;16:2860–2866. doi: 10.1021/acs.nanolett.6b00768. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Muralikrishna S. Sureshkumar K. Varley T. S. Nagaraju D. H. Ramakrishnappa T. In situ Reduction and Functionalization of Graphene Oxide with l-Cysteine for Simultaneous Electrochemical Determination of Cadmium(ii), Lead(ii), Copper(ii), and Mercury(ii) Ions. Anal. Methods. 2014;6:8698–8705. doi: 10.1039/C4AY01945H. [DOI] [Google Scholar]
- Zhang H. Shuang S. Wang G. Guo Y. Tong X. Yang P. Chen A. Dong C. Qin Y. TiO2–Graphene Hybrid Nanostructures by Atomic Layer Deposition With Enhanced Electrochemical Performance for Pb(ii) and Cd(ii) Detection. RSC Adv. 2015;5:4343–4349. doi: 10.1039/C4RA09779C. [DOI] [Google Scholar]
- Palanisamy S. Madhu R. Chen S.-M. Ramaraj S. K. A Highly Sensitive and Selective Electrochemical Determination of Hg(ii) Based on an Electrochemically Activated Graphite Modified Screen-Printed Carbon Electrode. Anal. Methods. 2014;6:8368–8373. doi: 10.1039/C4AY01805B. [DOI] [Google Scholar]
- Seenivasan R. Chang W.-J. Gunasekaran S. Highly Sensitive Detection and Removal of Lead Ions in Water Using Cysteine-Functionalized Graphene Oxide/Polypyrrole Nanocomposite Film Electrode. ACS Appl. Mater. Interfaces. 2015;7:15935–15943. doi: 10.1021/acsami.5b03904. [DOI] [PubMed] [Google Scholar]
- Yu C. Guo Y. Liu H. Yan N. Xu Z. Yu G. Fang Y. Liu Y. Ultrasensitive and Selective Sensing of Heavy Metal Ions with Modified Graphene. Chem. Commun. 2013;49:6492–6494. doi: 10.1039/C3CC42377H. [DOI] [PubMed] [Google Scholar]
- Aktar W. Sengupta D. Chowdhury A. Impact of Pesticides Use in Agriculture: Their Benefits and Hazards. Interdiscip. Toxicol. 2009;2:1–12. doi: 10.2478/v10102-009-0001-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gunnell D. Eddleston M. Phillips M. R. Konradsen F. The Global Distribution of Fatal Pesticide Self-Poisoning: Systematic Review. BMC Public Health. 2007;7:357. doi: 10.1186/1471-2458-7-357. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Grutzendler J. Morris J. C. Cholinesterase Inhibitors for Alzheimer's Disease. Drugs. 2001;61:41–52. doi: 10.2165/00003495-200161010-00005. [DOI] [PubMed] [Google Scholar]
- Deardorff W. J. Feen E. Grossberg G. T. The Use of Cholinesterase Inhibitors Across All Stages of Alzheimer's Disease. Drugs Aging. 2015;32:537–547. doi: 10.1007/s40266-015-0273-x. [DOI] [PubMed] [Google Scholar]
- Hung S.-Y. Fu W.-M. Drug Candidates in Clinical Trials for Alzheimer's Disease. J. Biomed. Sci. 2017;24:47. doi: 10.1186/s12929-017-0355-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Quinn D. M. Acetylcholinesterase: Enzyme Structure, Reaction Dynamics, and Virtual Transition States. Chem. Rev. 1987;87:955–979. doi: 10.1021/cr00081a005. [DOI] [Google Scholar]
- Tougu V. Acetylcholinesterase: Mechanism of Catalysis and Inhibition. Curr. Med. Chem.: Cent. Nerv. Syst. Agents. 2001;1:155–170. [Google Scholar]
- Colovic M. B. Krstic D. Z. Lazarevic-Pasti T. D. Bondzic A. M. Vasic V. M. Acetylcholinesterase Inhibitors: Pharmacology and Toxicology. Curr. Neuropharmacol. 2013;11:315–335. doi: 10.2174/1570159X11311030006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jaffrezic-Renault N. New Trends in Biosensors for Organophosphorus Pesticides. Sensors. 2001;1:60–74. doi: 10.3390/s10100060. [DOI] [Google Scholar]
- Narakathu B. B. Guo W. Obare S. O. Atashbar M. Z. Novel Approach for Detection of Toxic Organophosphorus Compounds. Sens. Actuators, B. 2011;158:69–74. doi: 10.1016/j.snb.2011.05.040. [DOI] [Google Scholar]
- Hassani S. Momtaz S. Vakhshiteh F. Maghsoudi A. S. Ganjali M. R. Norouzi P. Abdollahi M. Biosensors and Their Applications in Detection of Organophosphorus Pesticides in the Environment. Arch. Toxicol. 2017;91:109–130. doi: 10.1007/s00204-016-1875-8. [DOI] [PubMed] [Google Scholar]
- Yan X. Li H. Su X. Review of Optical Sensors for Pesticides. TrAC, Trends Anal. Chem. 2018;103:1–20. doi: 10.1016/j.trac.2018.03.004. [DOI] [Google Scholar]
- Viswanathan S. Radecka H. Radecki J. Electrochemical Biosensor for Pesticides Based on Acetylcholinesterase Immobilized on Polyaniline Deposited on Vertically Assembled Carbon Nanotubes Wrapped with ssDNA. Biosens. Bioelectron. 2009;24:2772–2777. doi: 10.1016/j.bios.2009.01.044. [DOI] [PubMed] [Google Scholar]
- Zhang W. Asiri A. M. Liu D. Du D. Lin Y. Nanomaterial-Based Biosensors for Environmental and Biological Monitoring of Organophosphorus Pesticides and Nerve Agents. TrAC, Trends Anal. Chem. 2014;54:1–10. doi: 10.1016/j.trac.2013.10.007. [DOI] [Google Scholar]
- Periasamy A. P. Umasankar Y. Chen S.-M. Nanomaterials-Acetylcholinesterase Enzyme Matrices for Organophosphorus Pesticides Electrochemical Sensors: A Review. Sensors. 2009;9:4034–4055. doi: 10.3390/s90604034. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jiang J. Zou S. Ma L. Wang S. Liao J. Zhang Z. Surface-Enhanced Raman Scattering Detection of Pesticide Residues Using Transparent Adhesive Tapes and Coated Silver Nanorods. ACS Appl. Mater. Interfaces. 2018;10:9129–9135. doi: 10.1021/acsami.7b18039. [DOI] [PubMed] [Google Scholar]
- Koh E. H. Mun C. Kim C. Park S.-G. Choi E. J. Kim S. H. Dang J. Choo J. Oh J.-W. Kim D.-H. Jung H. S. M13 Bacteriophage/Silver Nanowire Surface-Enhanced Raman Scattering Sensor for Sensitive and Selective Pesticide Detection. ACS Appl. Mater. Interfaces. 2018;10:10388–10397. doi: 10.1021/acsami.8b01470. [DOI] [PubMed] [Google Scholar]
- Huo D. Li Q. Zhang Y. Hou C. Lei Y. A Highly Efficient Organophosphorus Pesticides Sensor Based on CuO Nanowires–SWCNTs Hybrid Nanocomposite. Sens. Actuators, B. 2014;199:410–417. doi: 10.1016/j.snb.2014.04.016. [DOI] [Google Scholar]
- Kumar P. Paul A. K. Deep A. A Luminescent Nanocrystal Metal Organic Framework for Chemosensing of Nitro Group Containing Organophosphate Pesticides. Anal. Methods. 2014;6:4095–4101. doi: 10.1039/C3AY42189A. [DOI] [Google Scholar]
- Wu S. Lan X. Cui L. Zhang L. Tao S. Wang H. Han M. Liu Z. Meng C. Application of Graphene for Preconcentration and Highly Sensitive Stripping Voltammetric Analysis of Organophosphate Pesticide. Anal. Chim. Acta. 2011;699:170–176. doi: 10.1016/j.aca.2011.05.032. [DOI] [PubMed] [Google Scholar]
- Nasir M. Z. M. Mayorga-Martinez C. C. Sofer Z. Pumera M. Two-Dimensional 1T-Phase Transition Metal Dichalcogenides as Nanocarriers to Enhance and Stabilize Enzyme Activity for Electrochemical Pesticide Detection. ACS Nano. 2017;11:5774–5784. doi: 10.1021/acsnano.7b01364. [DOI] [PubMed] [Google Scholar]
- Yang L. Wang G. Liu Y. An Acetylcholinesterase Biosensor Based on Platinum Nanoparticles–Carboxylic Graphene–Nafion-Modified Electrode for Detection of Pesticides. Anal. Biochem. 2013;437:144–149. doi: 10.1016/j.ab.2013.03.004. [DOI] [PubMed] [Google Scholar]
- Yang L. Wang G. Liu Y. Wang M. Development of a Biosensor Based on Immobilization of Acetylcholinesterase on NiO Nanoparticles–Carboxylic Graphene–Nafion Modified Electrode for Detection of Pesticides. Talanta. 2013;113:135–141. doi: 10.1016/j.talanta.2013.03.025. [DOI] [PubMed] [Google Scholar]
- Zhou Q. Yang L. Wang G. Yang Y. Acetylcholinesterase Biosensor Based on SnO2 Nanoparticles–Carboxylic Graphene–Nafion Modified Electrode for Detection of Pesticides. Biosens. Bioelectron. 2013;49:25–31. doi: 10.1016/j.bios.2013.04.037. [DOI] [PubMed] [Google Scholar]
- Tan X. Hu Q. Wu J. Li X. Li P. Yu H. Li X. Lei F. Electrochemical Sensor Based on Molecularly Imprinted Polymer Reduced Graphene Oxide and Gold Nanoparticles Modified Electrode for Detection of Carbofuran. Sens. Actuators, B. 2015;220:216–221. doi: 10.1016/j.snb.2015.05.048. [DOI] [Google Scholar]
- Zhang M. Zhao H. T. Xie T. J. Yang X. Dong A. J. Zhang H. Wang J. Wang Z. Y. Molecularly Imprinted Polymer on Graphene Surface for Selective and Sensitive Electrochemical Sensing Imidacloprid. Sens. Actuators, B. 2017;252:991–1002. doi: 10.1016/j.snb.2017.04.159. [DOI] [Google Scholar]
- Jeyapragasam T. Saraswathi R. Chen S.-M. Chen T.-W. Acetylcholinesterase Biosensor for the Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode. Int. J. Electrochem. Sci. 2017;12:4768–4781. doi: 10.20964/2017.06.77. [DOI] [Google Scholar]
- Chao M. Chen M. Electrochemical Determination of Phoxim in Food Samples Employing a Graphene-Modified Glassy Carbon Electrode. Food Anal. Methods. 2014;7:1729–1736. doi: 10.1007/s12161-014-9813-y. [DOI] [Google Scholar]
- Wu L. Lei W. Han Z. Zhang Y. Xia M. Hao Q. A Novel Non-Enzyme Amperometric Platform Based on Poly(3-Methylthiophene)/Nitrogen Doped Graphene Modified Electrode for Determination of Trace Amounts of Pesticide Phoxim. Sens. Actuators, B. 2015;206:495–501. doi: 10.1016/j.snb.2014.09.098. [DOI] [Google Scholar]
- Zheng Y. Wang A. Lin H. Fu L. Cai W. A Sensitive Electrochemical Sensor for Direct Phoxim Detection Based on an Electrodeposited Reduced Graphene Oxide–Gold Nanocomposite. RSC Adv. 2015;5:15425–15430. doi: 10.1039/C4RA15872E. [DOI] [Google Scholar]
- Karimian N. Fakhri H. Amidi S. Hajian A. Arduini F. Bagheri H. A novel sensing layer based on metal-organic framework UiO-66 modified with TiO2-graphene oxide: application to rapid, sensitive and simultaneous determination of paraoxon and chlorpyrifos. New J. Chem. 2019;43:2600–2609. doi: 10.1039/C8NJ06208K. [DOI] [Google Scholar]
- Liu Q. Fei A. Huan J. Mao H. Wang K. Effective Amperometric Biosensor for Carbaryl Detection Based on Covalent Immobilization Acetylcholinesterase on Multiwall Carbon Nanotubes/Graphene Oxide Nanoribbons Nanostructure. J. Electroanal. Chem. 2015;740:8–13. doi: 10.1016/j.jelechem.2014.12.037. [DOI] [Google Scholar]
- Liu Y. Wang G. Li C. Zhou Q. Wang M. Yang L. A Novel Acetylcholinesterase Biosensor Based on Carboxylic Graphene Coated with Silver Nanoparticles for Pesticide Detection. Mater. Sci. Eng., C. 2014;35:253–258. doi: 10.1016/j.msec.2013.10.036. [DOI] [PubMed] [Google Scholar]
- Wang G. Tan X. Zhou Q. Liu Y. Wang M. Yang L. Synthesis of Highly Dispersed Zinc Oxide Nanoparticles on Carboxylic Graphene for Development a Sensitive Acetylcholinesterase Biosensor. Sens. Actuators, B. 2014;190:730–736. doi: 10.1016/j.snb.2013.09.042. [DOI] [Google Scholar]
- Zheng Y. Liu Z. Jing Y. Li J. Zhan H. An Acetylcholinesterase Biosensor Based on Ionic Liquid Functionalized Graphene–Gelatin-Modified Electrode for Sensitive Detection of Pesticides. Sens. Actuators, B. 2015;210:389–397. doi: 10.1016/j.snb.2015.01.003. [DOI] [Google Scholar]
- Zhang L. Zhang A. Du D. Lin Y. Biosensor Based on Prussian blue Nanocubes/Reduced Graphene Oxide Nanocomposite for Detection of Organophosphorus Pesticides. Nanoscale. 2012;4:4674–4679. doi: 10.1039/C2NR30976A. [DOI] [PubMed] [Google Scholar]
- Zhao H. Ji X. Wang B. Wang N. Li X. Ni R. Ren J. An Ultra-Sensitive Acetylcholinesterase Biosensor Based on Reduced Graphene Oxide-Au Nanoparticles-β-Cyclodextrin/Prussian Blue-Chitosan Nanocomposites for Organophosphorus Pesticides Detection. Biosens. Bioelectron. 2015;65:23–30. doi: 10.1016/j.bios.2014.10.007. [DOI] [PubMed] [Google Scholar]
- Cui H.-F. Wu W.-W. Li M.-M. Song X. Lv Y. Zhang T.-T. A Highly Stable Acetylcholinesterase Biosensor Based on Chitosan-TiO2-Graphene Nanocomposites for Detection of Organophosphate Pesticides. Biosens. Bioelectron. 2018;99:223–229. doi: 10.1016/j.bios.2017.07.068. [DOI] [PubMed] [Google Scholar]
- Ensafi A. A. Noroozi R. Zandi-Atashbar N. Rezaei B. Cerium(IV) Oxide Decorated on Reduced Graphene Oxide, a Selective and Sensitive Electrochemical Sensor for Fenitrothion Determination. Sens. Actuators, B. 2017;245:980–987. doi: 10.1016/j.snb.2017.01.186. [DOI] [Google Scholar]
- Shams N. Lim H. N. Hajian R. Yusof N. A. Abdullah J. Sulaiman Y. Ibrahim I. Huang N. M. Pandikumar A. A Promising Electrochemical Sensor Based on Au Nanoparticles Decorated Reduced Graphene Oxide for Selective Detection of Herbicide Diuron in Natural Waters. J. Appl. Electrochem. 2016;46:655–666. doi: 10.1007/s10800-016-0950-4. [DOI] [Google Scholar]
- Yang Y. Asiri A. M. Du D. Lin Y. Acetylcholinesterase Biosensor Based on a Gold Nanoparticle–Polypyrrole–Reduced Graphene Oxide Nanocomposite Modified Electrode for the Amperometric Detection Of Organophosphorus Pesticides. Analyst. 2014;139:3055–3060. doi: 10.1039/C4AN00068D. [DOI] [PubMed] [Google Scholar]
- Li Y. Zhang Y. Han G. Xiao Y. Li M. Zhou W. An Acetylcholinesterase Biosensor Based on Graphene/Polyaniline Composite Film for Detection of Pesticides. Chin. J. Chem. 2016;34:82–88. doi: 10.1002/cjoc.201500747. [DOI] [Google Scholar]
- Li Y. Shi L. Han G. Xiao Y. Zhou W. Electrochemical Biosensing of Carbaryl Based on Acetylcholinesterase Immobilized onto Electrochemically Inducing Porous Graphene Oxide Network. Sens. Actuators, B. 2017;238:945–953. doi: 10.1016/j.snb.2016.07.152. [DOI] [Google Scholar]
- Bao J. Hou C. Chen M. Li J. Huo D. Yang M. Luo X. Lei Y. Plant Esterase–Chitosan/Gold Nanoparticles–Graphene Nanosheet Composite-Based Biosensor for the Ultrasensitive Detection of Organophosphate Pesticides. J. Agric. Food Chem. 2015;63:10319–10326. doi: 10.1021/acs.jafc.5b03971. [DOI] [PubMed] [Google Scholar]
- Wu S. Huang F. Lan X. Wang X. Wang J. Meng C. Electrochemically Reduced Graphene Oxide and Nafion Nanocomposite for Ultralow Potential Detection of Organophosphate Pesticide. Sens. Actuators, B. 2013;177:724–729. doi: 10.1016/j.snb.2012.11.069. [DOI] [Google Scholar]
- Li Y. Zhao R. Shi L. Han G. Xiao Y. Acetylcholinesterase Biosensor Based on Electrochemically Inducing 3D Graphene Oxide Network/Multi-Walled Carbon Nanotube Composites for Detection of Pesticides. RSC Adv. 2017;7:53570–53577. doi: 10.1039/C7RA08226F. [DOI] [Google Scholar]
- Zheng Y. Liu Z. Zhan H. Li J. Zhang C. Studies on Electrochemical Organophosphate Pesticide (OP) Biosensor Design Based On Ionic Liquid Functionalized Graphene and a Co3O4 Nanoparticle Modified Electrode. Anal. Methods. 2016;8:5288–5295. doi: 10.1039/C6AY01346E. [DOI] [Google Scholar]
- Hondred J. A. Breger J. C. Alves N. J. Trammell S. A. Walper S. A. Medintz I. L. Claussen J. C. Printed Graphene Electrochemical Biosensors Fabricated by Inkjet Maskless Lithography for Rapid and Sensitive Detection of Organophosphates. ACS Appl. Mater. Interfaces. 2018;10:11125–11134. doi: 10.1021/acsami.7b19763. [DOI] [PubMed] [Google Scholar]
- de Silva A. P. Gunaratne H. Q. N. Gunnlaugsson T. Huxley A. J. M. McCoy C. P. Rademacher J. T. Rice T. E. Signaling Recognition Events with Fluorescent Sensors and Switches. Chem. Rev. 1997;97:1515–1566. doi: 10.1021/cr960386p. [DOI] [PubMed] [Google Scholar]
- Gao M. Tang B. Z. Fluorescent Sensors Based on Aggregation-Induced Emission: Recent Advances and Perspectives. ACS Sens. 2017;2:1382–1399. doi: 10.1021/acssensors.7b00551. [DOI] [PubMed] [Google Scholar]
- Kasry A. Ardakani A. A. Tulevski G. S. Menges B. Copel M. Vyklicky L. Highly Efficient Fluorescence Quenching with Graphene. J. Phys. Chem. C. 2012;116:2858–2862. doi: 10.1021/jp207972f. [DOI] [Google Scholar]
- Lin W. Tian B. Zhuang P. Yin J. Zhang C. Li Q. Shih T.-M. Cai W. Graphene-Based Fluorescence-Quenching-Related Fermi Level Elevation and Electron-Concentration Surge. Nano Lett. 2016;16:5737–5741. doi: 10.1021/acs.nanolett.6b02430. [DOI] [PubMed] [Google Scholar]
- Tian F. Lyu J. Shi J. Yang M. Graphene and Graphene-Like Two-Denominational Materials Based Fluorescence Resonance Energy Transfer (FRET) Assays for Biological Applications. Biosens. Bioelectron. 2017;89:123–135. doi: 10.1016/j.bios.2016.06.046. [DOI] [PubMed] [Google Scholar]
- Deka M. J. Chowdhury D. Tuning Electrical Properties of Graphene with Different π-Stacking Organic Molecules. J. Phys. Chem. C. 2016;120:4121–4129. doi: 10.1021/acs.jpcc.5b12403. [DOI] [Google Scholar]
- Li N. Than A. Wang X. Xu S. Sun L. Duan H. Xu C. Chen P. Ultrasensitive Profiling of Metabolites Using Tyramine-Functionalized Graphene Quantum Dots. ACS Nano. 2016;10:3622–3629. doi: 10.1021/acsnano.5b08103. [DOI] [PubMed] [Google Scholar]
- Zhang P. Zhao X. Ji Y. Ouyang Z. Wen X. Li J. Su Z. Wei G. Electrospinning Graphene Quantum Dots into a Nanofibrous Membrane for Dual-Purpose Fluorescent and Electrochemical Biosensors. J. Mater. Chem. B. 2015;3:2487–2496. doi: 10.1039/C4TB02092H. [DOI] [PubMed] [Google Scholar]
- Liu R. Yang R. Qu C. Mao H. Hu Y. Li J. Qu L. Synthesis of Glycine-Functionalized Graphene Quantum Dots as Highly Sensitive and Selective Fluorescent Sensor of Ascorbic Acid in Human Serum. Sens. Actuators, B. 2017;241:644–651. doi: 10.1016/j.snb.2016.10.096. [DOI] [Google Scholar]
- Tu Y. Li W. Wu P. Zhang H. Cai C. Fluorescence Quenching of Graphene Oxide Integrating with the Site-Specific Cleavage of the Endonuclease for Sensitive and Selective MicroRNA Detection. Anal. Chem. 2013;85:2536–2542. doi: 10.1021/ac303772m. [DOI] [PubMed] [Google Scholar]
- Li W. Hou T. Wu M. Li F. Label-Free Fluorescence Strategy for Sensitive MicroRNA Detection Based on Isothermal Exponential Amplification and Graphene Oxide. Talanta. 2016;148:116–121. doi: 10.1016/j.talanta.2015.10.078. [DOI] [PubMed] [Google Scholar]
- Tong C. Zhao C. Liu B. Li B. Ai Z. Fan J. Wang W. Sensitive Detection of RNase A Activity and Collaborative Drug Screening Based on rGO and Fluorescence Probe. Anal. Chem. 2018;90:2655–2661. doi: 10.1021/acs.analchem.7b04429. [DOI] [PubMed] [Google Scholar]
- Bhatnagar D. Kumar V. Kumar A. Kaur I. Graphene Quantum Dots FRET Based Sensor for Early Detection of Heart Attack in Human. Biosens. Bioelectron. 2016;79:495–499. doi: 10.1016/j.bios.2015.12.083. [DOI] [PubMed] [Google Scholar]
- Furukawa K. Ueno Y. Takamura M. Hibino H. Graphene FRET Aptasensor. ACS Sens. 2016;1:710–716. doi: 10.1021/acssensors.6b00191. [DOI] [Google Scholar]
- Shi J. Chan C. Pang Y. Ye W. Tian F. Lyu J. Zhang Y. Yang M. A Fluorescence Resonance Energy Transfer (FRET) Biosensor Based on Graphene Quantum Dots (GQDs) and Gold Nanoparticles (AuNPs) for the Detection of mecA Gene Sequence of Staphylococcus aureus. Biosens. Bioelectron. 2015;67:595–600. doi: 10.1016/j.bios.2014.09.059. [DOI] [PubMed] [Google Scholar]
- Abdelhamid H. N. Wu H.-F. Multifunctional Graphene Magnetic Nanosheet Decorated with Chitosan for Highly Sensitive Detection of Pathogenic Bacteria. J. Mater. Chem. B. 2013;1:3950–3961. doi: 10.1039/C3TB20413H. [DOI] [PubMed] [Google Scholar]
- Yuan F. Zhao H. Zhang Z. Gao L. Xu J. Quan X. Fluorescent Biosensor for Sensitive Analysis of Oxytetracycline Based on an Indirectly Labelled Long-Chain Aptamer. RSC Adv. 2015;5:58895–58901. doi: 10.1039/C5RA04025F. [DOI] [Google Scholar]
- Liu X. Wang F. Aizen R. Yehezkeli O. Willner I. Graphene Oxide/Nucleic-Acid-Stabilized Silver Nanoclusters: Functional Hybrid Materials for Optical Aptamer Sensing and Multiplexed Analysis of Pathogenic DNAs. J. Am. Chem. Soc. 2013;135:11832–11839. doi: 10.1021/ja403485r. [DOI] [PubMed] [Google Scholar]
- Wu S. Duan N. Ma X. Xia Y. Wang H. Wang Z. Zhang Q. Multiplexed Fluorescence Resonance Energy Transfer Aptasensor between Upconversion Nanoparticles and Graphene Oxide for the Simultaneous Determination of Mycotoxins. Anal. Chem. 2012;84:6263–6270. doi: 10.1021/ac301534w. [DOI] [PubMed] [Google Scholar]
- Sheng L. Ren J. Miao Y. Wang J. Wang E. PVP-Coated Graphene Oxide for Selective Determination of Ochratoxin A via Quenching Fluorescence of Free Aptamer. Biosens. Bioelectron. 2011;26:3494–3499. doi: 10.1016/j.bios.2011.01.032. [DOI] [PubMed] [Google Scholar]
- Lu Z. Chen X. Wang Y. Zheng X. Li C. M. Aptamer Based Fluorescence Recovery Assay for Aflatoxin B1 Using a Quencher System Composed of Quantum Dots and Graphene Oxide. Microchim. Acta. 2014;182:571–578. doi: 10.1007/s00604-014-1360-0. [DOI] [Google Scholar]
- Wang S. Zhang Y. Pang G. Zhang Y. Guo S. Tuning the Aggregation/Disaggregation Behavior of Graphene Quantum Dots by Structure-Switching Aptamer for High-Sensitivity Fluorescent Ochratoxin A Sensor. Anal. Chem. 2017;89:1704–1709. doi: 10.1021/acs.analchem.6b03913. [DOI] [PubMed] [Google Scholar]
- Li Z. Xue N. Ma H. Cheng Z. Miao X. An Ultrasensitive and Switch-on Platform for Aflatoxin B1 Detection in Peanut Based on the Fluorescence Quenching of Graphene Oxide-Gold Nanocomposites. Talanta. 2018;181:346–351. doi: 10.1016/j.talanta.2018.01.039. [DOI] [PubMed] [Google Scholar]
- Liu M. Zhao H. Chen S. Yu H. Zhang Y. Quan X. Label-Free Fluorescent Detection of Cu(ii) Ions Based on DNA Cleavage-Dependent Graphene-Quenched DNAzymes. Chem. Commun. 2011;47:7749–7751. doi: 10.1039/C1CC12006A. [DOI] [PubMed] [Google Scholar]
- Liu M. Zhao H. Chen S. Yu H. Zhang Y. Quan X. A “Turn-on” Fluorescent Copper Biosensor Based on DNA Cleavage-Dependent Graphene-Quenched DNAzyme. Biosens. Bioelectron. 2011;26:4111–4116. doi: 10.1016/j.bios.2011.04.006. [DOI] [PubMed] [Google Scholar]
- Wen Y. Peng C. Li D. Zhuo L. He S. Wang L. Huang Q. Xu Q.-H. Fan C. Metal ion-Modulated Graphene-DNAzyme Interactions: Design of a Nanoprobe for Fluorescent Detection of Lead(ii) Ions with High Sensitivity, Selectivity and Tunable Dynamic Range. Chem. Commun. 2011;47:6278–6280. doi: 10.1039/C1CC11486G. [DOI] [PubMed] [Google Scholar]
- Zhao X. Gao J. He X. Cong L. Zhao H. Li X. Tan F. DNA-Modified Graphene Quantum Dots as a Sensing Platform For Detection of Hg2+ in Living Cells. RSC Adv. 2015;5:39587–39591. doi: 10.1039/C5RA06984J. [DOI] [Google Scholar]
- Pang S. Liu S. Su X. An Ultrasensitive Sensing Strategy for the Detection of Lead (II) Ions Based on the Intermolecular G-Quadruplex and Graphene Oxide. Sens. Actuators, B. 2015;208:415–420. doi: 10.1016/j.snb.2014.11.030. [DOI] [Google Scholar]
- Li M. Zhou X. Guo S. Wu N. Detection of Lead (II) with a “Turn-On” Fluorescent Biosensor Based on Energy Transfer from CdSe/ZnS Quantum Dots to Graphene Oxide. Biosens. Bioelectron. 2013;43:69–74. doi: 10.1016/j.bios.2012.11.039. [DOI] [PubMed] [Google Scholar]
- Li M. Zhou X. Ding W. Guo S. Wu N. Fluorescent Aptamer-Functionalized Graphene Oxide Biosensor for Label-Free Detection of Mercury(II) Biosens. Bioelectron. 2013;41:889–893. doi: 10.1016/j.bios.2012.09.060. [DOI] [PubMed] [Google Scholar]
- Wang F. Gu Z. Lei W. Wang W. Xia X. Hao Q. Graphene Quantum Dots as a Fluorescent Sensing Platform for Highly Efficient Detection of Copper(II) Ions. Sens. Actuators, B. 2014;190:516–522. doi: 10.1016/j.snb.2013.09.009. [DOI] [Google Scholar]
- Qian Z. S. Shan X. Y. Chai L. J. Chen J. R. Feng H. A Fluorescent Nanosensor Based on Graphene Quantum Dots–Aptamer Probe and Graphene Oxide Platform for Detection of Lead (II) Ion. Biosens. Bioelectron. 2015;68:225–231. doi: 10.1016/j.bios.2014.12.057. [DOI] [PubMed] [Google Scholar]
- Cui X. Zhu L. Wu J. Hou Y. Wang P. Wang Z. Yang M. A Fluorescent Biosensor Based on Carbon Dots-Labeled Oligodeoxyribonucleotide and Graphene Oxide for Mercury (II) Detection. Biosens. Bioelectron. 2015;63:506–512. doi: 10.1016/j.bios.2014.07.085. [DOI] [PubMed] [Google Scholar]
- Chowdhury A. D. Doong R. A. Highly Sensitive and Selective Detection of Nanomolar Ferric Ions Using Dopamine Functionalized Graphene Quantum Dots. ACS Appl. Mater. Interfaces. 2016;8:21002–21010. doi: 10.1021/acsami.6b06266. [DOI] [PubMed] [Google Scholar]
- Shi X. Gu W. Peng W. Li B. Chen N. Zhao K. Xian Y. Sensitive Pb2+ Probe Based on the Fluorescence Quenching by Graphene Oxide and Enhancement of the Leaching of Gold Nanoparticles. ACS Appl. Mater. Interfaces. 2014;6:2568–2575. doi: 10.1021/am405012k. [DOI] [PubMed] [Google Scholar]
- Fang X. Liu Y. Jimenez L. Duan Y. Adkins G. B. Qiao L. Liu B. Zhong W. Rapid Enrichment and Sensitive Detection of Multiple Metal Ions Enabled by Macroporous Graphene Foam. Anal. Chem. 2017;89:11758–11764. doi: 10.1021/acs.analchem.7b03336. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhu X. Zhang Z. Xue Z. Huang C. Shan Y. Liu C. Qin X. Yang W. Chen X. Wang T. Understanding the Selective Detection of Fe3+ Based on Graphene Quantum Dots as Fluorescent Probes: The Ksp of a Metal Hydroxide-Assisted Mechanism. Anal. Chem. 2017;89:12054–12058. doi: 10.1021/acs.analchem.7b02499. [DOI] [PubMed] [Google Scholar]
- Fang B.-Y. Li C. Song Y.-Y. Tan F. Cao Y.-C. Zhao Y.-D. Nitrogen-Doped Graphene Quantum Dot for Direct Fluorescence Detection of Al3+ in Aqueous Media and Living Cells. Biosens. Bioelectron. 2018;100:41–48. doi: 10.1016/j.bios.2017.08.057. [DOI] [PubMed] [Google Scholar]
- Bian S. Shen C. Qian Y. Liu J. Xi F. Dong X. Facile Synthesis of Sulfur-Doped Graphene Quantum Dots as Fluorescent Sensing Probes For Ag+ Ions Detection. Sens. Actuators, B. 2017;242:231–237. doi: 10.1016/j.snb.2016.11.044. [DOI] [Google Scholar]
- Wang C. Yang F. Tang Y. Yang W. Zhong H. Yu C. Li R. Zhou H. Li Y. Mao L. Graphene Quantum Dots Nanosensor Derived from 3D Nanomesh Graphene Frameworks and its Application For Fluorescent Sensing of Cu2+ in Rat Brain. Sens. Actuators, B. 2018;258:672–681. doi: 10.1016/j.snb.2017.11.098. [DOI] [Google Scholar]
- Niu X. Zhong Y. Chen R. Wang F. Liu Y. Luo D. A “Turn-on” Fluorescence Sensor for Pb2+ Detection Based on Graphene Quantum Dots and Gold Nanoparticles. Sens. Actuators, B. 2018;255:1577–1581. doi: 10.1016/j.snb.2017.08.167. [DOI] [Google Scholar]
- Peng D. Zhang L. Liang R.-P. Qiu J.-D. Rapid Detection of Mercury Ions Based on Nitrogen-Doped Graphene Quantum Dots Accelerating Formation of Manganese Porphyrin. ACS Sens. 2018;3:1040–1047. doi: 10.1021/acssensors.8b00203. [DOI] [PubMed] [Google Scholar]
- Zhang C. Lin B. Cao Y. Guo M. Yu Y. Fluorescence Determination of Omethoate Based on a Dual Strategy for Improving Sensitivity. J. Agric. Food Chem. 2017;65:3065–3073. doi: 10.1021/acs.jafc.7b00166. [DOI] [PubMed] [Google Scholar]
- Liu Y. Cao N. Gui W. Ma Q. Nitrogen-Doped Graphene Quantum Dots-Based Fluorescence Molecularly Imprinted Sensor for Thiacloprid Detection. Talanta. 2018;183:339–344. doi: 10.1016/j.talanta.2018.01.063. [DOI] [PubMed] [Google Scholar]
- Chen J.-L. Yan X.-P. Meng K. Wang S.-F. Graphene Oxide Based Photoinduced Charge Transfer Label-Free Near-Infrared Fluorescent Biosensor for Dopamine. Anal. Chem. 2011;83:8787–8793. doi: 10.1021/ac2023537. [DOI] [PubMed] [Google Scholar]
- Cheng R. Ge C. Qi L. Zhang Z. Ma J. Huang H. Pan T. Dai Q. Dai L. Label-Free Graphene Oxide Förster Resonance Energy Transfer Sensors for Selective Detection of Dopamine in Human Serums and Cells. J. Phys. Chem. C. 2018;122:13314–13321. doi: 10.1021/acs.jpcc.7b09256. [DOI] [Google Scholar]
- Xing X.-J. Xiao W.-L. Liu X.-G. Zhou Y. Pang D.-W. Tang H.-W. A Fluorescent Aptasensor Using Double-Stranded DNA/Graphene Oxide as the Indicator Probe. Biosens. Bioelectron. 2016;78:431–437. doi: 10.1016/j.bios.2015.11.076. [DOI] [PubMed] [Google Scholar]
- Chen L. Song L. Zhang Y. Wang P. Xiao Z. Guo Y. Cao F. Nitrogen and Sulfur Codoped Reduced Graphene Oxide as a General Platform for Rapid and Sensitive Fluorescent Detection of Biological Species. ACS Appl. Mater. Interfaces. 2016;8:11255–11261. doi: 10.1021/acsami.6b01030. [DOI] [PubMed] [Google Scholar]
- Zhang H. Wang Y. Zhao D. Zeng D. Xia J. Aldalbahi A. Wang C. San L. Fan C. Zuo X. Mi X. Universal Fluorescence Biosensor Platform Based on Graphene Quantum Dots and Pyrene-Functionalized Molecular Beacons for Detection of MicroRNAs. ACS Appl. Mater. Interfaces. 2015;7:16152–16156. doi: 10.1021/acsami.5b04773. [DOI] [PubMed] [Google Scholar]
- Alonso-Cristobal P. Vilela P. El-Sagheer A. Lopez-Cabarcos E. Brown T. Muskens O. L. Rubio-Retama J. Kanaras A. G. Highly Sensitive DNA Sensor Based on Upconversion Nanoparticles and Graphene Oxide. ACS Appl. Mater. Interfaces. 2015;7:12422–12429. doi: 10.1021/am507591u. [DOI] [PubMed] [Google Scholar]
- Huang L.-J. Tian X. Yi J.-T. Yu R.-Q. Chu X. A Turn-on Upconversion Fluorescence Resonance Energy Transfer Biosensor for Ultrasensitive Endonuclease Detection. Anal. Methods. 2015;7:7474–7479. doi: 10.1039/C5AY01169H. [DOI] [Google Scholar]
- Justino C. I. L. Rocha-Santos T. A. Duarte A. C. Rocha-Santos T. A. Review of Analytical Figures of Merit of Sensors and Biosensors in Clinical Applications. TrAC, Trends Anal. Chem. 2010;29:1172–1183. doi: 10.1016/j.trac.2010.07.008. [DOI] [Google Scholar]
- Liu M. Song J. Shuang S. Dong C. Brennan J. D. Li Y. A Graphene-Based Biosensing Platform Based on the Release of DNA Probes and Rolling Circle Amplification. ACS Nano. 2014;8:5564–5573. doi: 10.1021/nn5007418. [DOI] [PubMed] [Google Scholar]
- Hong C. Baek A. Hah S. S. Jung W. Kim D.-E. Fluorometric Detection of MicroRNA Using Isothermal Gene Amplification and Graphene Oxide. Anal. Chem. 2016;88:2999–3003. doi: 10.1021/acs.analchem.6b00046. [DOI] [PubMed] [Google Scholar]
- Fan X. Qi Y. Shi Z. Lv Y. Guo Y. A Graphene-Based Biosensor for Detecting microRNA with Augmented Sensitivity Through Helicase-Assisted Signal Amplification of Hybridization Chain Reaction. Sens. Actuators, B. 2018;255:1582–1586. doi: 10.1016/j.snb.2017.08.183. [DOI] [Google Scholar]
- Shi Z. Zhang X. Cheng R. Li B. Jin Y. Sensitive Detection of Intracellular RNA of Human Telomerase by Using Graphene Oxide as a Carrier to Deliver the Assembly Element of Hybridization Chain Reaction. Analyst. 2016;141:2727–2732. doi: 10.1039/C6AN00233A. [DOI] [PubMed] [Google Scholar]
- Yang L. Liu C. Ren W. Li Z. Graphene Surface-Anchored Fluorescence Sensor for Sensitive Detection of MicroRNA Coupled with Enzyme-Free Signal Amplification of Hybridization Chain Reaction. ACS Appl. Mater. Interfaces. 2012;4:6450–6453. doi: 10.1021/am302268t. [DOI] [PubMed] [Google Scholar]
- Yan H. Xu Y. Lu Y. Xing W. Reduced Graphene Oxide-Based Solid-Phase Extraction for the Enrichment and Detection of microRNA. Anal. Chem. 2017;89:10137–10140. doi: 10.1021/acs.analchem.7b03138. [DOI] [PubMed] [Google Scholar]
- Huang Y. Liu X. Zhang L. Hu K. Zhao S. Fang B. Chen Z.-F. Liang H. Nicking Enzyme and Graphene Oxide-Based Dual Signal Amplification for Ultrasensitive Aptamer-Based Fluorescence Polarization Assays. Biosens. Bioelectron. 2015;63:178–184. doi: 10.1016/j.bios.2014.07.036. [DOI] [PubMed] [Google Scholar]
- Yan X. Li W. Liu K. Deng L. Highly Sensitive Fluorescent Aptasensor for Salmonella paratyphi A via DNase I-Mediated Cyclic Signal Amplification. Anal. Methods. 2015;7:10243–10250. doi: 10.1039/C5AY02298C. [DOI] [Google Scholar]
- Ge J. Huang Z.-M. Xi Q. Yu R.-Q. Jiang J.-H. Chu X. A Novel Graphene Oxide Based Fluorescent Nanosensing Strategy with Hybridization Chain Reaction Signal Amplification for Highly Sensitive Biothiol Detection. Chem. Commun. 2014;50:11879–11882. doi: 10.1039/C4CC05309E. [DOI] [PubMed] [Google Scholar]
- Wen J. Li W. Li J. Tao B. Xu Y. Li H. Lu A. Sun S. Study on Rolling Circle Amplification of Ebola Virus and Fluorescence Detection based on Graphene Oxide. Sens. Actuators, B. 2016;227:655–659. doi: 10.1016/j.snb.2016.01.036. [DOI] [Google Scholar]
- Zhao X.-H. Kong R.-M. Zhang X.-B. Meng H.-M. Liu W.-N. Tan W. Shen G.-L. Yu R.-Q. Graphene–DNAzyme Based Biosensor for Amplified Fluorescence “Turn-on” Detection of Pb2+ with a High Selectivity. Anal. Chem. 2011;83:5062–5066. doi: 10.1021/ac200843x. [DOI] [PubMed] [Google Scholar]
- (a) Peng H. Newbigging A. M. Wang Z. Tao J. Deng W. Le X. C. Zhang H. DNAzyme-Mediated Assays for Amplified Detection of Nucleic Acids and Proteins. Anal. Chem. 2018;90:190–207. doi: 10.1021/acs.analchem.7b04926. [DOI] [PubMed] [Google Scholar]; (b) Breaker R. R. Joyce G. F. A DNA enzyme that cleaves RNA. Chem. Biol. 1994;1:223–229. doi: 10.1016/1074-5521(94)90014-0. [DOI] [PubMed] [Google Scholar]
- Xi Q. Li J.-J. Du W.-F. Yu R.-Q. Jiang J.-H. A Highly Sensitive Strategy for Base Excision Repair Enzyme Activity Detection Based on Graphene Oxide Mediated Fluorescence Quenching and Hybridization Chain Reaction. Analyst. 2016;141:96–99. doi: 10.1039/C5AN02255J. [DOI] [PubMed] [Google Scholar]
- Mitra R. Saha A. Reduced Graphene Oxide Based “Turn-On” Fluorescence Sensor for Highly Reproducible and Sensitive Detection of Small Organic Pollutants. ACS Sustainable Chem. Eng. 2017;5:604–615. doi: 10.1021/acssuschemeng.6b01971. [DOI] [Google Scholar]
- Wen Y. Xing F. He S. Song S. Wang L. Long Y. Li D. Fan C. A Graphene-Based Fluorescent Nanoprobe for Silver(i) Ions Detection by Using Graphene Oxide and A Silver-Specific Oligonucleotide. Chem. Commun. 2010;46:2596–2598. doi: 10.1039/B924832C. [DOI] [PubMed] [Google Scholar]
- Wang C. Yang S. Yi M. Liu C. Wang Y. Li J. Li Y. Yang R. Graphene Oxide Assisted Fluorescent Chemodosimeter for High-Performance Sensing and Bioimaging of Fluoride Ions. ACS Appl. Mater. Interfaces. 2014;6:9768–9775. doi: 10.1021/am502142d. [DOI] [PubMed] [Google Scholar]
- Ananthanarayanan A. Wang X. Routh P. Sana B. Lim S. Kim D.-H. Lim K.-H. Li J. Chen P. Facile Synthesis of Graphene Quantum Dots from 3D Graphene and their Application for Fe3+ Sensing. Adv. Funct. Mater. 2014;24:3021–3026. doi: 10.1002/adfm.201303441. [DOI] [Google Scholar]
- Guo R. Zhou S. Li Y. Li X. Fan L. Voelcker N. H. Rhodamine-Functionalized Graphene Quantum Dots for Detection of Fe3+ in Cancer Stem Cells. ACS Appl. Mater. Interfaces. 2015;7:23958–23966. doi: 10.1021/acsami.5b06523. [DOI] [PubMed] [Google Scholar]
- Li S. Li Y. Cao J. Zhu J. Fan L. Li X. Sulfur-Doped Graphene Quantum Dots as a Novel Fluorescent Probe for Highly Selective and Sensitive Detection of Fe3+ Anal. Chem. 2014;86:10201–10207. doi: 10.1021/ac503183y. [DOI] [PubMed] [Google Scholar]
- Zor E. Morales-Narváez E. Zamora-Gálvez A. Bingol H. Ersoz M. Merkoçi A. Graphene Quantum Dots-based Photoluminescent Sensor: A Multifunctional Composite for Pesticide Detection. ACS Appl. Mater. Interfaces. 2015;7:20272–20279. doi: 10.1021/acsami.5b05838. [DOI] [PubMed] [Google Scholar]
- Gao L. Ju L. Cui H. Chemiluminescent and Fluorescent Dual-Signal Graphene Quantum Dots and Their Application in Pesticide Sensing Arrays. J. Mater. Chem. C. 2017;5:7753–7758. doi: 10.1039/C7TC01658A. [DOI] [Google Scholar]
- Yan X. Song Y. Zhu C. Song J. Du D. Su X. Lin Y. Graphene Quantum Dot–MnO2 Nanosheet Based Optical Sensing Platform: A Sensitive Fluorescence “Turn off–on” Nanosensor for Glutathione Detection and Intracellular Imaging. ACS Appl. Mater. Interfaces. 2016;8:21990–21996. doi: 10.1021/acsami.6b05465. [DOI] [PubMed] [Google Scholar]
- Nemati F. Hosseini M. Zare-Dorabei R. Ganjali M. R. Sensitive Recognition of Ethion in Food Samples Using Turn-on Fluorescence N and S Co-Doped Graphene Quantum Dots. Anal. Methods. 2018;10:1760–1766. doi: 10.1039/C7AY02850D. [DOI] [Google Scholar]
- Kotlowski C. Larisika M. Guerin P. M. Kleber C. Kröber T. Mastrogiacomo R. Nowak C. Pelosi P. Schütz S. Schwaighofer A. Knoll W. Fine Discrimination of Volatile Compounds by Graphene-Immobilized Odorant-Binding Proteins. Sens. Actuators, B. 2018;256:564–572. doi: 10.1016/j.snb.2017.10.093. [DOI] [Google Scholar]
- Choi S.-J. Kim S.-J. Kim I.-D. Ultrafast Optical Reduction of Graphene Oxide Sheets on Colorless Polyimide Film for Wearable Chemical Sensors. NPG Asia Mater. 2016;8:e315. doi: 10.1038/am.2016.150. [DOI] [Google Scholar]
- Facure M. H. M. Mercante L. A. Mattoso L. H. C. Correa D. S. Detection of Trace Levels of Organophosphate Pesticides Using an Electronic Tongue Based on Graphene Hybrid Nanocomposites. Talanta. 2017;167:59–66. doi: 10.1016/j.talanta.2017.02.005. [DOI] [PubMed] [Google Scholar]
- Kim K. S. Jang J.-r. Choe W.-S. Yoo P. J. Electrochemical Detection of Bisphenol A with High Sensitivity and Selectivity Using Recombinant Protein-Immobilized Graphene Electrodes. Biosens. Bioelectron. 2015;71:214–221. doi: 10.1016/j.bios.2015.04.042. [DOI] [PubMed] [Google Scholar]
- Gupta S. Wood R. Development of FRET Biosensor Based on Aptamer/Functionalized Graphene for Ultrasensitive Detection of Bisphenol A and Discrimination from Analogs. Nano-Struct. Nano-Objects. 2017;10:131–140. doi: 10.1016/j.nanoso.2017.03.013. [DOI] [Google Scholar]
- Myung S. Solanki A. Kim C. Park J. Kim K. S. Lee K.-B. Graphene-Encapsulated Nanoparticle-Based Biosensor for the Selective Detection of Cancer Biomarkers. Adv. Mater. 2011;23:2221–2225. doi: 10.1002/adma.201100014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Khatayevich D. Page T. Gresswell C. Hayamizu Y. Grady W. Sarikaya M. Selective Detection of Target Proteins by Peptide-Enabled Graphene Biosensor. Small. 2014;10:1505–1513. doi: 10.1002/smll.201302188. [DOI] [PubMed] [Google Scholar]
- Tomita S. Ishihara S. Kurita R. A Multi-Fluorescent DNA/Graphene Oxide Conjugate Sensor for Signature-Based Protein Discrimination. Sensors. 2017;17:E2194. doi: 10.3390/s17102194. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Si P. Chen H. Kannan P. Kim D.-H. Selective and Sensitive Determination of Dopamine by Composites of Polypyrrole and Graphene Modified Electrodes. Analyst. 2011;136:5134–5138. doi: 10.1039/C1AN15772H. [DOI] [PubMed] [Google Scholar]
- Hou S. Kasner M. L. Su S. Patel K. Cuellari R. Highly Sensitive and Selective Dopamine Biosensor Fabricated with Silanized Graphene. J. Phys. Chem. C. 2010;114:14915–14921. doi: 10.1021/jp1020593. [DOI] [Google Scholar]
- Dong S. Bi Q. Qiao C. Sun Y. Zhang X. Lu X. Zhao L. Electrochemical Sensor for Discrimination Tyrosine Enantiomers Using Graphene Quantum Dots and B-Cyclodextrins Composites. Talanta. 2017;173:94–100. doi: 10.1016/j.talanta.2017.05.045. [DOI] [PubMed] [Google Scholar]
- Ganganboina A. B. Chowdhury A. D. Doong R.-A. N-Doped Graphene Quantum Dots-Decorated V2O5 Nanosheet for Fluorescence Turn Off–On Detection of Cysteine. ACS Appl. Mater. Interfaces. 2017;10:614–624. doi: 10.1021/acsami.7b15120. [DOI] [PubMed] [Google Scholar]
- Anh N. T. N. Doong R.-a. One-Step Synthesis of Size-Tunable Gold@Sulfur-Doped Graphene Quantum Dot Nanocomposites for Highly Selective and Sensitive Detection of Nanomolar 4-Nitrophenol in Aqueous Solutions with Complex Matrix. ACS Appl. Nano Mater. 2018;1:2153–2163. doi: 10.1021/acsanm.8b00210. [DOI] [Google Scholar]
- Pei H. Li J. Lv M. Wang J. Gao J. Lu J. Li Y. Huang Q. Hu J. Fan C. A Graphene-Based Sensor Array for High-Precision and Adaptive Target Identification with Ensemble Aptamers. J. Am. Chem. Soc. 2012;134:13843–13849. doi: 10.1021/ja305814u. [DOI] [PubMed] [Google Scholar]
- Chou S. S. De M. Luo J. Rotello V. M. Huang J. Dravid V. P. Nanoscale Graphene Oxide (nGO) as Artificial Receptors: Implications for Biomolecular Interactions and Sensing. J. Am. Chem. Soc. 2012;134:16725–16733. doi: 10.1021/ja306767y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kwok R. T. K. Leung C. W. T. Lam J. W. Y. Tang B. Z. Biosensing by Luminogens with Aggregation-Induced Emission Characteristics. Chem. Soc. Rev. 2015;44:4228–4238. doi: 10.1039/C4CS00325J. [DOI] [PubMed] [Google Scholar]
- Mei J. Huang Y. Tian H. Progress and Trends in AIE-Based Bioprobes: A Brief Overview. ACS Appl. Mater. Interfaces. 2017;10:12217–12261. doi: 10.1021/acsami.7b14343. [DOI] [PubMed] [Google Scholar]
- Hong Y. Meng L. Chen S. Leung C. W. T. Da L.-T. Faisal M. Silva D.-A. Liu J. Lam J. W. Y. Huang X. Tang B. Z. Monitoring and Inhibition of Insulin Fibrillation by a Small Organic Fluorogen with Aggregation-Induced Emission Characteristics. J. Am. Chem. Soc. 2012;134:1680–1689. doi: 10.1021/ja208720a. [DOI] [PubMed] [Google Scholar]
- Li X. Ma K. Zhu S. Yao S. Liu Z. Xu B. Yang B. Tian W. Fluorescent Aptasensor Based on Aggregation-Induced Emission Probe and Graphene Oxide. Anal. Chem. 2013;86:298–303. doi: 10.1021/ac403629t. [DOI] [PubMed] [Google Scholar]
- Liu J.-W. Luo Y. Wang Y.-M. Duan L.-Y. Jiang J.-H. Yu R.-Q. Graphitic Carbon Nitride Nanosheets-Based Ratiometric Fluorescent Probe for Highly Sensitive Detection of H2O2 and Glucose. ACS Appl. Mater. Interfaces. 2016;8:33439–33445. doi: 10.1021/acsami.6b11207. [DOI] [PubMed] [Google Scholar]
- Zhao L. Chen Y. Yuan J. Chen M. Zhang H. Li X. Electrospun Fibrous Mats with Conjugated Tetraphenylethylene and Mannose for Sensitive Turn-On Fluorescent Sensing of Escherichia coli. ACS Appl. Mater. Interfaces. 2015;7:5177–5186. doi: 10.1021/am507593p. [DOI] [PubMed] [Google Scholar]
- Shen J. Hu R. Zhou T. Wang Z. Zhang Y. Li S. Gui C. Jiang M. Qin A. Tang B. Z. Fluorescent Sensor Array for Highly Efficient Microbial Lysate Identification through Competitive Interactions. ACS Sens. 2018;3:2218–2222. doi: 10.1021/acssensors.8b00650. [DOI] [PubMed] [Google Scholar]
- Xu X. Huang J. Li J. Yan J. Qin J. Li Z. A Graphene Oxide-Based AIE Biosensor with High Selectivity Toward Bovine Serum Albumin. Chem. Commun. 2011;47:12385–12387. doi: 10.1039/C1CC15735C. [DOI] [PubMed] [Google Scholar]
- Huang X. Deng X. Qi W. Wu D. Simultaneous Detection of Hydroquinone and Catechol Using Platinum Nanoparticles Decorated Graphene/Poly-Cyclodextrin/Multiwalled Carbon Nanotubes (MWCNTs) Nanocomposite Based Biosensor. J. Nanosci. Nanotechnol. 2018;18:8118–8123. doi: 10.1166/jnn.2018.16295. [DOI] [PubMed] [Google Scholar]
- Chang H. Wu X. Wu C. Chen Y. Jiang H. Wang X. Catalytic oxidation and determination of β-NADH using self-assembly hybrid of gold nanoparticles and graphene. Analyst. 2011;136:2735–2740. doi: 10.1039/C1AN15197E. [DOI] [PubMed] [Google Scholar]
- Yan Y. Liu Q. Du X. Qian J. Mao H. Wang K. Visible Light Photoelectrochemical Sensor for Ultrasensitive Determination of Dopamine Based on Synergistic Effect of Graphene Quantum Dots and TiO2 Nanoparticles. Anal. Chim. Acta. 2015;853:258–264. doi: 10.1016/j.aca.2014.10.021. [DOI] [PubMed] [Google Scholar]
- Zhao Z.-Q. Chen X. Yang Q. Liu J.-H. Huang X.-J. Selective Adsorption Toward Toxic Metal Ions Results in Selective Response: Electrochemical Studies on A Polypyrrole/Reduced Graphene Oxide Nanocomposite. Chem. Commun. 2012;48:2180–2182. doi: 10.1039/C1CC16735A. [DOI] [PubMed] [Google Scholar]
- Mao X. Su H. Tian D. Li H. Yang R. Bipyrene-functionalized graphene as a “turn-on” fluorescence sensor for manganese (II) ions in living cells. ACS Appl. Mater. Interfaces. 2013;5:592–597. doi: 10.1021/am3026807. [DOI] [PubMed] [Google Scholar]
- Sun H. Gao N. Wu L. Ren J. Wei W. Qu X. Highly Photoluminescent Amino-Functionalized Graphene Quantum Dots Used for Sensing Copper Ions. Chem.–Eur. J. 2013;19:13362–13368. doi: 10.1002/chem.201302268. [DOI] [PubMed] [Google Scholar]
- Xu L. Mao W. Huang J. Li S. Huang K. Li M. Xia J. Chen Q. Economical, Green Route to Highly Fluorescence Intensity Carbon Materials Based on Ligninsulfonate/Graphene Quantum Dots Composites: Application as Excellent Fluorescent Sensing Platform for Detection of Fe3+ Ions. Sens. Actuators, B. 2016;230:54–60. doi: 10.1016/j.snb.2015.12.043. [DOI] [Google Scholar]
- Göde C. Yola M. L. Yılmaz A. Atar N. Wang S. A Novel Electrochemical Sensor Based on Calixarene Functionalized Reduced Graphene Oxide: Application to Simultaneous Determination of Fe(III), Cd(II) and Pb(II) Ions. J. Colloid Interface Sci. 2017;508:525–531. doi: 10.1016/j.jcis.2017.08.086. [DOI] [PubMed] [Google Scholar]
- Salehnia F. Faridbod F. Dezfuli A. S. Ganjali M. R. Norouzi P. Cerium(III) Ion Sensing Based on Graphene Quantum Dots Fluorescent Turn-Off. J. Fluoresc. 2017;27:331–338. doi: 10.1007/s10895-016-1962-5. [DOI] [PubMed] [Google Scholar]
- Ruecha N. Rodthongkum N. Cate D. M. Volckens J. Chailapakul O. Henry C. S. Sensitive Electrochemical Sensor Using a Graphene–Polyaniline Nanocomposite for Simultaneous Detection of Zn(II), Cd(II), and Pb(II) Anal. Chim. Acta. 2015;874:40–48. doi: 10.1016/j.aca.2015.02.064. [DOI] [PubMed] [Google Scholar]
- Bagheri H. Afkhami A. Khoshsafar H. Rezaei M. Sabounchei S. J. Sarlakifar M. Simultaneous Electrochemical Sensing of Thallium, Lead and Mercury Using a Novel Ionic Liquid/Graphene Modified Electrode. Anal. Chim. Acta. 2015;870:56–66. doi: 10.1016/j.aca.2015.03.004. [DOI] [PubMed] [Google Scholar]
- Afkhami A. Shirzadmehr A. Madrakian T. Bagheri H. New Nano-Composite Potentiometric Sensor Composed of Graphene Nanosheets/Thionine/Molecular Wire for Nanomolar Detection of Silver Ion in Various Real Samples. Talanta. 2015;131:548–555. doi: 10.1016/j.talanta.2014.08.004. [DOI] [PubMed] [Google Scholar]
- Jiang X. Chen K. Wang J. Shao K. Fu T. Shao F. Lu D. Liang J. Foda M. F. Han H. Solid-State Voltammetry-Based Electrochemical Immunosensor for Escherichia coli Using Graphene Oxide–Ag Nanoparticle Composites as Labels. Analyst. 2013;138:3388–3393. doi: 10.1039/C3AN00056G. [DOI] [PubMed] [Google Scholar]
- Zhang J. Ran F. Zhou W. Shang B. Yu F. Wu L. Hu W. He X. Chen Q. Ultrasensitive fluorescent aptasensor for MUC1 detection based on deoxyribonuclease I-aided target recycling signal amplification. RSC Adv. 2018;8:32009–32015. doi: 10.1039/C8RA06498A. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thakur B. Zhou G. Chang J. Pu H. Jin B. Sui X. Yuan X. Yang C.-H. Magruder M. Chen J. Rapid Detection of Single E. coli Bacteria Using a Graphene-Based Field-Effect Transistor Device. Biosens. Bioelectron. 2018;110:16–22. doi: 10.1016/j.bios.2018.03.014. [DOI] [PubMed] [Google Scholar]
- Xu S. Duo H. Zheng C. Zhao S. Song S. Simon G. Novel approach to fabrication of DNA Biosensor Based on a Carboxylated Graphene Oxide Decorated with Fe3O4 NPs for the Detection of Typhoidal Salmonella. Int. J. Electrochem. Sci. 2019;14:1248–1269. doi: 10.20964/2019.02.44. [DOI] [Google Scholar]
- Mathur A. Gupta R. Kondal S. Wadhwa S. Pudake R. N. Shivani Kansal R. Pundir C. S. Narang J. A New Tactics for the Detection of S. aureus via Paper Based Geno-Interface Incorporated with Graphene Nano Dots And Zeolites. Int. J. Biol. Macromol. 2018;112:364–370. doi: 10.1016/j.ijbiomac.2018.01.143. [DOI] [PubMed] [Google Scholar]
- Chand R. Wang Y. L. Kelton D. Neethirajan S. Isothermal DNA amplification with functionalized graphene and nanoparticle assisted electroanalysis for rapid detection of Johne's disease. Sens. Actuators, B. 2018;261:31–37. doi: 10.1016/j.snb.2018.01.140. [DOI] [Google Scholar]
- Yang J. Zhang Z. Yan G. An Aptamer-Mediated CdSe/ZnS QDs@Graphene Oxid Composite Fluorescent Probe for Specific Detection of Insulin. Sens. Actuators, B. 2018;255:2339–2346. doi: 10.1016/j.snb.2017.09.046. [DOI] [Google Scholar]
- Wang M. Lin Z. Liu Q. Jiang S. Liu H. Su X. DNA-Hosted Copper Nanoclusters/Graphene Oxide Based Fluorescent Biosensor for Protein Kinase Activity Detection. Anal. Chim. Acta. 2018;1012:66–73. doi: 10.1016/j.aca.2018.01.029. [DOI] [PubMed] [Google Scholar]
- Zou J. Zhao G. Q. Teng J. Liu Q. Jiang X. Y. Jiao F. P. Yu J. G. Highly sensitive detection of bisphenol A in real water samples based on in situ assembled graphene nanoplatelets and gold nanoparticles composite. Microchem. J. 2019;145:693–702. doi: 10.1016/j.microc.2018.11.040. [DOI] [Google Scholar]
- Velusamy V. Palanisamy S. Chen S. W. Balu S. Yang T. C. Banks C. E. Novel electrochemical synthesis of cellulose microfiber entrapped reduced graphene oxide: a sensitive electrochemical assay for detection of fenitrothion organophosphorus pesticide. Talanta. 2019;192:471–477. doi: 10.1016/j.talanta.2018.09.055. [DOI] [PubMed] [Google Scholar]
- Tian L. Qi J. Qian K. Oderinde O. Cai Y. Yao C. Song W. Wang Y. An ultrasensitive electrochemical cytosensor based on the magnetic field assisted binanozymes synergistic catalysis of Fe3O4 nanozyme and reduced graphene oxide/molybdenum disulfide nanozyme. Sens. Actuators, B. 2018;260:676–684. doi: 10.1016/j.snb.2018.01.092. [DOI] [Google Scholar]
- Shahrokhian S. Salimian R. Ultrasensitive detection of cancer biomarkers using conducting polymer/electrochemically reduced graphene oxide-based biosensor: application toward BRCA1 sensing. Sens. Actuators, B. 2018;266:160–169. doi: 10.1016/j.snb.2018.03.120. [DOI] [Google Scholar]
- Afsahi S. Lerner M. B. Goldstein J. M. Lee J. Tang X. Bagarozzi Jr D. A. Pan D. Locascio L. Walker A. Barron F. Goldsmith B. R. Novel graphene-based biosensor for early detection of Zika virus infection. Biosens. Bioelectron. 2018;100:85–88. doi: 10.1016/j.bios.2017.08.051. [DOI] [PubMed] [Google Scholar]
- Li L. Yuan Y. Chen Y. Zhang P. Bai Y. Bai L. Aptamer based voltammetric biosensor for Mycobacterium tuberculosis antigen ESAT-6 using a nanohybrid material composed of reduced graphene oxide and a metal-organic framework. Microchim. Acta. 2018;185:379. doi: 10.1007/s00604-018-2884-5. [DOI] [PubMed] [Google Scholar]
- Xuan X. Yoon H. S. Park J. Y. A wearable electrochemical glucose sensor based on simple and low-cost fabrication supported micro-patterned reduced graphene oxide nanocomposite electrode on flexible substrate. Biosens. Bioelectron. 2018;109:75–82. doi: 10.1016/j.bios.2018.02.054. [DOI] [PubMed] [Google Scholar]
- (a) Yang L. Liu B. Wang M. Li J. Pan W. Gao X. Li N. Tang B. A Highly Sensitive Strategy for Fluorescence Imaging of MicroRNA in Living Cells and In vivo Based on Graphene Oxide-Enhanced Signal Molecules Quenching of Molecular Beacon. ACS Appl. Mater. Interfaces. 2018;10:6982–6990. doi: 10.1021/acsami.7b19284. [DOI] [PubMed] [Google Scholar]; (b) Ou X. Zhan S. Sun C. Cheng Y. Wang X. Liu B. Zhai T. Lou X. Xia F. Simultaneous detection of telomerase and miRNA with graphene oxide-based fluorescent aptasensor in living cells and tissue samples. Biosens. Bioelectron. 2019;124:199–204. doi: 10.1016/j.bios.2018.10.009. [DOI] [PubMed] [Google Scholar]
- Chen S. Cheng Y. F. Voordouw G. Three-dimensional graphene nanosheet doped with gold nanoparticles as electrochemical DNA biosensor for bacterial detection. Sens. Actuators, B. 2018;262:860–868. doi: 10.1016/j.snb.2018.02.093. [DOI] [Google Scholar]
- Zou W. Gong F. Gu T. Cao Z. Xia J. An efficient strategy for sensing pyrophosphate based on nitrogen-rich quantum dots combined with graphene oxide. Microchem. J. 2018;141:466–472. doi: 10.1016/j.microc.2018.06.004. [DOI] [Google Scholar]
- Sadeghi A. S. Mohsenzadeh M. Abnous K. Taghdisi S. M. Ramezani M. Development and characterization of DNA aptamers against florfenicol: fabrication of a sensitive fluorescent aptasensor for specific detection of florfenicol in milk. Talanta. 2018;182:193–201. doi: 10.1016/j.talanta.2018.01.083. [DOI] [PubMed] [Google Scholar]
- Tian J. Wei W. Wang J. Ji S. Chen G. Lu J. Fluorescence resonance energy transfer aptasensor between nanoceria and graphene quantum dots for the determination of ochratoxin A. Anal. Chim. Acta. 2018;1000:265–272. doi: 10.1016/j.aca.2017.08.018. [DOI] [PubMed] [Google Scholar]
- Venu M. Venkateswarlu S. Reddy Y. V. M. Seshadri Reddy A. Gupta V. K. Yoon M. Madhavi G. Highly Sensitive Electrochemical Sensor for Anticancer Drug by a Zirconia Nanoparticle-Decorated Reduced Graphene Oxide Nanocomposite. ACS Omega. 2018;3:14597–14605. doi: 10.1021/acsomega.8b02129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu X. Na W. Liu Q. Su X. A novel label-free fluorescent sensor for highly sensitive detection of bleomycin based on nitrogen-doped graphene quantum dots. Anal. Chim. Acta. 2018;1028:45–49. doi: 10.1016/j.aca.2018.04.038. [DOI] [PubMed] [Google Scholar]
- Tabrizi M. A. Ferré-Borrull J. Kapruwan P. Marsal L. F. A photoelectrochemical sandwich immunoassay for protein S100β, a biomarker for Alzheimer's disease, using an ITO electrode modified with a reduced graphene oxide-gold conjugate and CdS-labeled secondary antibody. Microchim. Acta. 2019;186:117. doi: 10.1007/s00604-018-3159-x. [DOI] [PubMed] [Google Scholar]
- Gui W. Zhang J. Chen X. Yu D. Ma Q. N-Doped graphene quantum dot@ mesoporous silica nanoparticles modified with hyaluronic acid for fluorescent imaging of tumor cells and drug delivery. Microchim. Acta. 2018;185:66. doi: 10.1007/s00604-017-2598-0. [DOI] [PubMed] [Google Scholar]
- Chekin F. Bagga K. Subramanian P. Jijie R. Singh S. K. Kurungot S. Boukherroub R. Szunerits S. Nucleic aptamer modified porous reduced graphene oxide/MoS2 based electrodes for viral detection: application to human papillomavirus (HPV) Sens. Actuators, B. 2018;262:991–1000. doi: 10.1016/j.snb.2018.02.065. [DOI] [Google Scholar]
- Navakul K. Warakulwit C. Yenchitsomanus P. T. Panya A. Lieberzeit P. A. Sangma C. A novel method for dengue virus detection and antibody screening using a graphene-polymer based electrochemical biosensor. Nanomedicine. 2017;13:549–557. doi: 10.1016/j.nano.2016.08.009. [DOI] [PubMed] [Google Scholar]
- Xiang Q. Huang J. Huang H. Mao W. Ye Z. A label-free electrochemical platform for the highly sensitive detection of hepatitis B virus DNA using graphene quantum dots. RSC Adv. 2018;8:1820–1825. doi: 10.1039/C7RA11945C. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Muain M. F. A. Cheo K. H. Omar M. N. Hamzah A. S. A. Lim H. N. Salleh A. B. Tan W. S. Tajudin A. A. Gold nanoparticle-decorated reduced-graphene oxide targeting anti hepatitis B virus core antigen. Bioelectrochemistry. 2018;122:199–205. doi: 10.1016/j.bioelechem.2018.04.004. [DOI] [PubMed] [Google Scholar]
- Valipour A. Roushani M. Using silver nanoparticle and thiol graphene quantum dots nanocomposite as a substratum to load antibody for detection of hepatitis C virus core antigen: electrochemical oxidation of riboflavin was used as redox probe. Biosens. Bioelectron. 2017;89:946–951. doi: 10.1016/j.bios.2016.09.086. [DOI] [PubMed] [Google Scholar]
- Ruiyi L. Fangchao C. Haiyan Z. Xiulan S. Zaijun L. Electrochemical sensor for detection of cancer cell based on folic acid and octadecylamine-functionalized graphene aerogel microspheres. Biosens. Bioelectron. 2018;119:156–162. doi: 10.1016/j.bios.2018.07.060. [DOI] [PubMed] [Google Scholar]
- Zhou Q. Yan H. Ran F. Cao J. Chen L. Shang B. Chen H. Wei J. Chen Q. Ultrasensitive enzyme-free fluorescent detection of VEGF 165 based on target-triggered hybridization chain reaction amplification. RSC Adv. 2018;8(46):25955–25960. doi: 10.1039/C8RA04721A. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu D. Lu X. Yang Y. Zhai Y. Zhang J. Li L. A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform. Anal. Bioanal. Chem. 2018;410:4285–4291. doi: 10.1007/s00216-018-1076-9. [DOI] [PubMed] [Google Scholar]
- Sandil D. Srivastava S. Malhotra B. D. Sharma S. C. Puri N. K. Biofunctionalized tungsten trioxide-reduced graphene oxide nanocomposites for sensitive electrochemical immunosensing of cardiac biomarker. J. Alloys Compd. 2018;763:102–110. doi: 10.1016/j.jallcom.2018.04.293. [DOI] [Google Scholar]
- Gevaerd A. Blaskievicz S. F. Zarbin A. J. Orth E. S. Bergamini M. F. Marcolino-Junior L. H. Nonenzymatic electrochemical sensor based on imidazole-functionalized graphene oxide for progesterone detection. Biosens. Bioelectron. 2018;112:108–113. doi: 10.1016/j.bios.2018.04.044. [DOI] [PubMed] [Google Scholar]
- Liu M. Ke H. Sun C. Wang G. Wang Y. Zhao G. A simple and highly selective electrochemical label-free aptasensor of 17β-estradiol based on signal amplification of bi-functional graphene. Talanta. 2019;194:266–272. doi: 10.1016/j.talanta.2018.10.035. [DOI] [PubMed] [Google Scholar]
- Lee J. H. Choi H. K. Yang L. Chueng S. T. D. Choi J. W. Lee K. B. Nondestructive Real-Time Monitoring of Enhanced Stem Cell Differentiation Using a Graphene-Au Hybrid Nanoelectrode Array. Adv. Mater. 2018;30:1802762. doi: 10.1002/adma.201802762. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gao F. Wu J. Yao Y. Zhang Y. Liao X. Geng D. Tang D. Proximity hybridization triggered strand displacement and DNAzyme assisted strand recycling for ATP fluorescence detection in vitro and imaging in living cells. RSC Adv. 2018;8:28161–28171. doi: 10.1039/C8RA05193C. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yu S. Li H. Li G. Niu L. Liu W. Di X. Reduced graphene oxide-supported gold dendrite for electrochemical sensing of acetaminophen. Talanta. 2018;184:244–250. doi: 10.1016/j.talanta.2018.03.011. [DOI] [PubMed] [Google Scholar]
- Li W. Zhu J. Xie G. Ren Y. Zheng Y. Q. Ratiometric system based on graphene quantum dots and Eu3+ for selective detection of tetracyclines. Anal. Chim. Acta. 2018;1022:131–137. doi: 10.1016/j.aca.2018.03.018. [DOI] [PubMed] [Google Scholar]
- Jiang T. Tan H. Sun Y. Wang J. Hang Y. Lu N. Yang J. Qu X. Hua J. Graphene oxide-based NIR fluorescence probe with aggregation-induced emission property for lectins detection and liver cells targeting. Sens. Actuators, B. 2018;261:115–126. doi: 10.1016/j.snb.2017.10.163. [DOI] [Google Scholar]
- Siraj N. El-Zahab B. Hamdan S. Karam T. E. Haber L. H. Li M. Fakayode S. O. Das S. Valle B. Strongin R. M. Patonay G. Sintim H. O. Baker G. A. Powe A. Lowry M. Karolin J. O. Geddes C. D. Warner I. M. Fluorescence, Phosphorescence, and Chemiluminescence. Anal. Chem. 2015;88:170–202. doi: 10.1021/acs.analchem.5b04109. [DOI] [PubMed] [Google Scholar]
- Zhang H. Ba S. Mahajan D. Lee J. Y. Ye R. Shao F. Lu L. Li T. Versatile Types of DNA-Based Nanobiosensors for Specific Detection of Cancer Biomarker FEN1 in Living Cells and Cell-Free Systems. Nano Lett. 2018;18:7383–7388. doi: 10.1021/acs.nanolett.8b03724. [DOI] [PubMed] [Google Scholar]
- Shang Z. Qian L. Liu S. Niu X. Qiao Z. Sun Y. Zhang Y. Fan L. Y. Guan X. Cao C. X. Xiao H. Graphene Oxide-Facilitated Comprehensive Analysis of Cellular Nucleic Acid Binding Proteins for Lung Cancer. ACS Appl. Mater. Interfaces. 2018;10:17756–17770. doi: 10.1021/acsami.8b05428. [DOI] [PubMed] [Google Scholar]
- Jin D. Yang F. Zhang Y. Liu L. Zhou Y. Wang F. Zhang G. J. ExoAPP: Exosome-Oriented, Aptamer Nanoprobe-Enabled Surface Proteins Profiling and Detection. Anal. Chem. 2018;90:14402–14411. doi: 10.1021/acs.analchem.8b03959. [DOI] [PubMed] [Google Scholar]
- Heidari R. Rashidiani J. Abkar M. Taheri R. A. Moghaddam M. M. Mirhosseini S. A. Seidmoradi R. Nourani M. R. Mahboobi M. Keihan A. H. Kooshki H. CdS nanocrystals/graphene oxide-AuNPs based electrochemiluminescence immunosensor in sensitive quantification of a cancer biomarker: p53. Biosens. Bioelectron. 2019;126:7–14. doi: 10.1016/j.bios.2018.10.031. [DOI] [PubMed] [Google Scholar]
- Serafín V. Valverde A. Martínez-García G. Martínez-Periñán E. Comba F. Garranzo-Asensio M. Barderas R. Yáñez-Sedeño P. Campuzano S. Pingarrón J. M. Graphene quantum dots-functionalized multi-walled carbon nanotubes as nanocarriers in electrochemical immunosensing. Determination of IL-13 receptor α2 in colorectal cells and tumor tissues with different metastatic potential. Sens. Actuators, B. 2019;284:711–722. doi: 10.1016/j.snb.2019.01.012. [DOI] [Google Scholar]
- Tian C. Wang L. Luan F. Zhuang X. An electrochemiluminescence sensor for the detection of prostate protein antigen based on the graphene quantum dots infilled TiO2 nanotube arrays. Talanta. 2019;191:103–108. doi: 10.1016/j.talanta.2018.08.050. [DOI] [PubMed] [Google Scholar]
- Khan M. S. Zhu W. Ali A. Ahmad S. M. Li X. Yang L. Wang Y. Wang H. Wei Q. Electrochemiluminescent immunosensor for prostate specific antigen based upon luminol functionalized platinum nanoparticles loaded on graphene. Anal. Biochem. 2019;566:50–57. doi: 10.1016/j.ab.2018.11.010. [DOI] [PubMed] [Google Scholar]
- Singh S. Nalwa H. S. Nanotechnology and health safety–toxicity and risk assessments of nanostructured materials on human health. J. Nanosci. Nanotechnol. 2007;7:3048–3070. doi: 10.1166/jnn.2007.922. [DOI] [PubMed] [Google Scholar]
- Nanotoxicology: Interactions of Nanomaterials with Biological Systems, ed. Y. Zhao and H. S. Nalwa, American Scientific Publishers, Los Angeles, 2007 [Google Scholar]
- Yang K. Li Y. Tan X. Peng R. Liu Z. Behavior and toxicity of graphene and its functionalized derivatives in biological systems. Small. 2013;9:1492–1503. doi: 10.1002/smll.201201417. [DOI] [PubMed] [Google Scholar]
- Zhang B. Wei P. Zhou Z. Wei T. Interactions of graphene with mammalian cells: molecular mechanisms and biomedical insights. Adv. Drug Delivery Rev. 2016;105:145–162. doi: 10.1016/j.addr.2016.08.009. [DOI] [PubMed] [Google Scholar]
- Ema M. Gamo M. Honda K. A review of toxicity studies on graphene-based nanomaterials in laboratory animals. Regul. Toxicol. Pharmacol. 2017;85:7–24. doi: 10.1016/j.yrtph.2017.01.011. [DOI] [PubMed] [Google Scholar]
- Shareena T. P. D. McShan D. Dasmahapatra A. K. Tchounwou P. B. A review on graphene-based nanomaterials in biomedical applications and risks in environment and health. Nano-Micro Lett. 2018;10:53. doi: 10.1007/s40820-018-0206-4. [DOI] [PMC free article] [PubMed] [Google Scholar]