Reply to: Mallett unit or fully fusionable images for prisms against asthenopia?

Bruce John William Evans a,, Ketan Parmar b, Christine Dickinson b
PMCID: PMC9068569  PMID: 34670731

We thank Professors Kommerell and Bach for their interest in our article.1 Mallett advocated the use of a trial frame with his test as it allows a normal head posture and visual field.2 Mallett advocated using small step sizes (1D horizontally);2 “gradually increasing the strength until the slip disappears – never the reverse procedure”;3 and “between changes of prisms or spheres the patient should read two or three lines of print surrounding the target”.3 These instructions depart markedly from the procedure adopted by Kommerell and Bach,4 where the participant continuously adjusts a Risley prism, on several occasions starting with 10Δ, and is asked to “play a little”(with the prism power). We agree with Kommerell and Bach, their method did not aim at the smallest power of the prisms and may not be appropriate for prescribing.

We understand how a consideration of natural viewing led Kommerell and Bach to the interesting approach of self-selected prism.4 The assumption behind this test seems to be that following a period of self-adjustment of a Risley prism, a subject's selection of the prism power they find most relaxing may be therapeutically helpful. We question this hypothesis for several reasons, most notably that the self-selected prism fluctuates considerably from one day to another4 and subjects may select the strongest prism they can tolerate, not the weakest.

We accept that Kommerell and Bach's avoidance of Nonius markers is a step towards normal viewing conditions, but we suggest that various aspects of their experimental design, including the participant adjustment of Risley prisms, takes this approach several steps further away from normal viewing conditions. In support of this we note, the prism powers found by Kommerell and Bach4 are generally more than double those typically obtained with the Mallett unit, when used as recommended.5 We made the comment in our manuscript advising against using self-adjusted Risley prisms because of concerns that if clinicians use the Mallett unit in this way they could inappropriately over-prescribe prisms, both in the proportion of patients to whom prisms are prescribed and in the magnitude of prism.

Practitioners who use the Mallett unit tend to only prescribe prisms of low power to a small minority of patients with significant symptoms associated with visual tasks when other treatment approaches are unsuitable.6 For example, NHS statistics for Scotland indicate ∼1% of NHS funded lenses supplied by community optometrists include a prism.7 We are not surprised8 that these data on actual practice differ markedly from surveys of practitioners’ choices given hypothetical prescribing scenarios.9

There is experimental evidence supporting the use of the Mallett unit for detecting symptomatic heterophoria10 and for prescribing.11,12 As Kommerell and Bach note, there is a fairly large body of research that has used the Mallett unit following the designer's instructions.6 Our concern is that, since the test results are sensitive to differences in instructions13 and test design,1 if clinicians use the test in an unintended way this could lead to unintended consequences, including the over-prescribing of prisms.

References

  • 1.Parmar KR, Dickinson C, Evans BJW. Does an iPad fixation disparity test give equivalent results to the Mallett near fixation disparity test? J Optom. 2019;12(4):222–231. doi: 10.1016/j.optom.2019.03.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Mallett R. In: Optometry. Edwards K, Llewellyn R, editors. Butterworths; London: 1988. Techniques of investigation of binocular vision anomalies; pp. 238–269. [Google Scholar]
  • 3.Mallett RFJ. i.o.o. Sales Ltd; London: 1997. Mallett near vision unit. [Google Scholar]
  • 4.Kommerell G, Kromeier M, Scharff F, et al. Asthenopia, associated phoria, and self-selected prism. Strabismus. 2015;23(2):51–65. doi: 10.3109/09273972.2015.1036080. [DOI] [PubMed] [Google Scholar]
  • 5.Pickwell LD, Kaye NA, Jenkins TCA. Distance and near readings of associated heterophoria taken on 500 patients. Ophthal Physiol Opt. 1991;11:291–296. [PubMed] [Google Scholar]
  • 6.Evans BJW. 6th ed. Elsevier; Philadelphia: 2021. Pickwell's Binocular Vision Anomalies. [Google Scholar]
  • 7.NHS Services Scotland . Information Services Division, ed. National Statistics, NHS; 2019. General ophthalmic services statistics. [Google Scholar]
  • 8.Shah R, Edgar DF, Evans BJW. A Comparison of standardised patients, record abstraction and clinical vignettes for the purpose of measuring clinical practice. Ophthal Physiol Opt. 2010;30(3):209–224. doi: 10.1111/j.1475-1313.2010.00713.x. [DOI] [PubMed] [Google Scholar]
  • 9.O'Leary CI, Evans BJW. Criteria for prescribing optometric interventions: literature review and practitioner survey. Ophthal Physiol Opt. 2003;23:429–439. doi: 10.1046/j.1475-1313.2003.00137.x. [DOI] [PubMed] [Google Scholar]
  • 10.Jenkins TCA, Pickwell LD, Yekta AA. Criteria for decompensation in binocular vision. Ophthal Physiol Opt. 1989;9:121–125. doi: 10.1111/j.1475-1313.1989.tb00830.x. [DOI] [PubMed] [Google Scholar]
  • 11.Payne CR, Grisham JD, Thomas KL. A clinical examination of fixation disparity. Am J Ophthal Physiol Opt. 1974;51(2):88–90. [Google Scholar]
  • 12.O'Leary CI, Evans BJW. Double-masked randomised placebo-controlled trial of the effect of prismatic corrections on rate of reading and the relationship with symptoms. Ophthal Physiol Opt. 2006;26(6):555–565. doi: 10.1111/j.1475-1313.2006.00400.x. [DOI] [PubMed] [Google Scholar]
  • 13.Karania R, Evans BJ. The Mallett Fixation Disparity Test: influence of test instructions & relationship with symptoms. Ophthal Physiol Opt. 2006;26:507–522. doi: 10.1111/j.1475-1313.2006.00385.x. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Optometry are provided here courtesy of Elsevier

RESOURCES