Screening for SARS-CoV-2 in close contacts of individuals with confirmed infection: performance and operational considerations

Stephanie Zobrist 1,#,, Michelle Oliveira-Silva 2,#, Alexia Martines Vieira 2, Pooja Bansil 1, Emily Gerth-Guyette 1, Brandon T Leader 1, Allison Golden 1, Hannah Slater 1, Catherine Duran de Lucena Cruz 2, Eduardo Garbin 2, Mariana Sagalovsky 1, Sampa Pal 1, Vin Gupta 3, Leo Wolansky 4, Deusilene Souza Vieira Dall’Acqua 5, Gomes Felipe Naveca 6, Valdinete Alves do Nascimento 6, Juan Miguel Villalobos Salcedo 5, Paul K Drain 7, Alexandre Dias Tavares Costa 8, Gonzalo J Domingo 1, Dhélio Pereira 2
PMCID: PMC9129181  PMID: 35594905

Abstract

Background

Point-of-care and decentralized testing for SARS-CoV-2 is critical to inform public health responses. Performance evaluations in priority use cases such as contact tracing can highlight trade-offs in test selection and testing strategies.

Methods

A prospective diagnostic accuracy study was conducted among close contacts of COVID-19 cases in Brazil. Two anterior nares swabs (ANS), a nasopharyngeal swab (NPS), and saliva were collected at all visits. Vaccination history and symptoms were assessed. Household contacts were followed longitudinally. Three rapid antigen tests and one molecular method were evaluated for usability and performance against reference RT-PCR on NPS.

Results

Fifty index cases and 214 contacts (64 household) were enrolled. Sixty-five contacts were RT-PCR positive during at least one visit. Vaccination did not influence viral load. Gamma variants were most prevalent; Delta emerged increasingly during implementation. Overall sensitivity of evaluated tests ranged from 33%–76%. Performance was higher among symptomatic cases and cases with Ct < 34 and lower among oligo/asymptomatic cases. Assuming a 24-hour time-to-result for RT-PCR, the cumulative sensitivity of an ANS rapid antigen test was >70% and almost 90% after four days.

Conclusions

The near immediate time-to-result for antigen tests significantly offsets lower analytical sensitivity in settings where RT-PCR results are delayed or unavailable.

Keywords: Porto Velho, Rondônia, Allplex™ SARS-CoV-2 Assay, SalivaDirect, SD Biosensor STANDARD Q COVID-19 Ag, LumiraDx SARS-CoV-2 Ag Test