A multiscale X-ray phase-contrast tomography dataset of a whole human left lung

R Patrick Xian 1,✉,#, Claire L Walsh 1, Stijn E Verleden 2, Willi L Wagner 3,4, Alexandre Bellier 5, Sebastian Marussi 1, Maximilian Ackermann 6,7, Danny D Jonigk 8,9, Joseph Jacob 10,11, Peter D Lee 1,, Paul Tafforeau 12,✉,#
PMCID: PMC9163096  PMID: 35654864

Abstract

Technological advancements in X-ray imaging using bright and coherent synchrotron sources now allows the decoupling of sample size and resolution while maintaining high sensitivity to the microstructures of soft, partially dehydrated tissues. The continuous developments in multiscale X-ray imaging resulted in hierarchical phase-contrast tomography, a comprehensive approach to address the challenge of organ-scale (up to tens of centimeters) soft tissue imaging with resolution and sensitivity down to the cellular level. Using this technique, we imaged ex vivo an entire human left lung at an isotropic voxel size of 25.08 μm along with local zooms down to 6.05–6.5 μm and 2.45–2.5 μm in voxel size. The high tissue contrast offered by the fourth-generation synchrotron source at the European Synchrotron Radiation Facility reveals the complex multiscale anatomical constitution of the human lung from the macroscopic (centimeter) down to the microscopic (micrometer) scale. The dataset provides comprehensive organ-scale 3D information of the secondary pulmonary lobules and delineates the microstructure of lung nodules with unprecedented detail.

Subject terms: Anatomy, Respiration, X-ray tomography


Measurement(s) Human left lung
Technology Type(s) X-Ray Phase-Contrast Imaging

Background & Summary

The human lung is among the largest solid organs in the human body. Traditionally, studies of lung microanatomy at the organ scale require lengthy operations in targeted sampling, tissue preparation, histological staining, and sectioning1,2. Nowadays, ex vivo clinical evaluations of whole lung microstructures are carried out without sectioning using absorption-contrast micro-CT at around 100 μm voxel size. A limited area of the lung may then be selected for imaging at higher resolution using histology35. X-ray phase-contrast imaging6,7 provides higher sensitivity and contrast than laboratory micro-CT8. Compared with optical virtual histology9, X-ray phase contrast from free-space propagation requires no imaging optics and, at the same time, removes the need for laborious tissue clearing and fluorescent labeling that are essential for optical imaging10. The compatibility of X-ray phase-contrast imaging with existing X-ray sources will facilitate its gradual adoption and transition from preclinical research to clinical diagnostics6,11,12. At synchrotron facilities, systematic upgrades13,14 in the X-ray source and imaging techniques over the past decades provide the means to tackle biological questions across meaningful scales and resolution11,1520. Although synchrotron-based X-ray imaging can access finer anatomical detail than laboratory micro-CT19,2123, many bioimaging scenarios require further upscaling of the imaging throughput and accommodation of large sample size while maintaining microscopic resolution24,25.

Thanks to the high X-ray photon flux and spatial coherence achieved at modern fourth-generation synchrotron sources and careful design of the sample preparation and imaging protocol, it is now possible to image complete, large, partially dehydrated human organs in their entirety at micrometer resolution using hierarchical phase-contrast tomography (HiP-CT)26. The technique integrates a multiscale imaging workflow4,2730 into a single setup, utilizing propagation phase contrast obtained from high-energy, polychromatic X-rays and tunable detection settings. Therefore, scanning an entire human organ (with a size of 5–30 cm in each dimension) at multiple resolutions can be executed without dissecting the sample or requiring to transport to different instrument locations or facilities27,28,30. HiP-CT features a customized flat-field correction, an attenuation scanning protocol, along with an efficient tomographic sampling and stitching pipeline to cover large, soft-tissue organs entirely, without staining27,31 or clearing10. The integrated single-modality, multiscale imaging approach of HiP-CT26 ensures a simplified image registration procedure thanks to the consistent tissue contrast across lengthscales. Its imaging protocol takes inspiration from existing multiscale approaches4,18,19,29, starting with a two-step tomographic sampling of the whole organ (full-field tomography), followed by progressive zoom-ins to selected features of the microanatomy through local tomographies at various finer resolutions compatible with the relevant anatomical context. HiP-CT requires the sample such as a soft-tissue organ to be embedded in 70% ethanol solution in water and immobilized with agar blocks throughout imaging (see Fig. 1a,b). The flat-field correction takes reference from a separate container (reference jar) of the same size as the sample jar to enhance the soft tissue contrast (see Fig. 1c). We provide here the dataset of an intact human left lung imaged by HiP-CT at 25.08 μm voxel size (full organ, see Fig. 1d) and at 6.05–6.5 μm and 2.45–2.5 μm voxel sizes for various local volumes of interest (VOIs) accomplished by optimization of the incident X-ray spectrum, propagation distance, scintillator thickness, and the coupling optics before the detector (see Methods). The X-ray imaging experiments were carried out at the European Synchrotron Radiation Facility (ESRF) BM05 beamline using the recently upgraded fourth-generation extremely brilliant X-ray source (ESRF-EBS)32,33.

Fig. 1.

Fig. 1

(a) A human left lung in lateral (left) and medial (right) view. (b) The instillation-fixed whole lung is mounted in a sealed, size-compatible, plastic cylindrical PET jar (140 mm in diameter, 260 mm in height) filled with 70% ethanol solution and agar blocks. (c) Sketch of the HiP-CT imaging setup using propagation phase contrast from bright and coherent X-rays at ESRF BM05 beamline. The reference jar contains the same embedding medium as the sample jar. The incident X-ray energy is adjusted to 70–85 keV through filters depending on the resolution requirement. (d) Volume rendering of the whole left lung imaged at 25.08 μm voxel size using HiP-CT in lateral (left) and medial (right) views. Major anatomical features labeled in a,b,d are the (1) left upper lobe, (2) interlobar fissure, (3) left lower lobe, (4) left mainstem bronchus.

Methods

Lung preparation and mounting

The entire left lung (see Fig. 1a) was harvested from a body donor, a 94-year-old woman who succumbed to natural causes, with the medical record provided in Table 1. Body donation was based on free consent by the donor antemortem. The relevant postmortem medical procedures were carried out at Laboratoire d’Anatomie des Alpes Françaises (LADAF) according to the Quality Appraisal for Cadaveric Studies scale recommendations34. All dissections respected the memory of the deceased. The protocols for transport and imaging were approved by the French legislation for body donation. The body of the deceased donor was embalmed and the lung preparations were carried out at ~36 hours postmortem. The lung was instilled through the trachea with a 4% formalin solution using 30 cm of water column positive pressure. The trachea was then ligatured to maintain the inflated configuration in order to fix the lungs in a non-collapsed state. The body was then kept at 4 °C for 3 days before the dissection. Once removed, the lungs were immersed in 4% formalin solution for 3 more days. Afterwards, it was successively immersed in ethanol solutions (odorless bioethanol, Cheminol, France) with increasing concentration up to 70% (volume fraction). The lung was kept inflated during ethanol dehydration by repeatedly pushing the solution through its main bronchus with a syringe. The significantly lower density of ethanol (789 kg/m3) compared with water (1000 kg/m3) provides a high base contrast for soft tissues35,36.

Table 1.

Medical record of the body donor.

Donor institution Laboratoire d’Anatomie des Alpes Françaises
Location Grenoble, France
Donor ID LADAF-2020-27
Age 94
Sex Female
Weight 45 kg
Height 140 cm
Ethnicity Caucasian
Time of death 2020
Cause of death Natural cause
Smoking history No
Donor medical information 1. Right sylvian and right cerebellar stroke
2. Cognitive disorders of vascular origin
3. Depressive syndrome
4. Atrial fibrillation and hypertensive heart disease
5. Micro-crystalline arthritis (gout)
6. Right lung pneumopathy (3 years before death)
7. Cataract of the left eye
8. Squamous cell carcinoma of the skin (left temporal region)

We used a PET (polyethylene terephthalate) jar of comparable size to the lung for X-ray imaging due to its commercial availability (3600 mL Sweep Jars with Cap, Medline Scientific, UK), high radiation tolerance37 and optical transparency in assisting sample alignment and assessment of sample condition during imaging. To secure the lung tightly in place and prevent it from touching the container edges on all sides, we prepared agar (Agar-Agar powder, from wild red seaweed, Nat-Ali, France) blocks in ~1 cm3-sized cubes and stacked them at the bottom of the jar and around the organ to firmly embed the lung. The procedure for the agar preparation has been thoroughly described preivously26. The gaps between the small agar blocks provide the escape routes for residual gas removal. The sample mounting procedure involves alternated filling of the agar-ethanol mixture and gentle vacuum degassing to minimize the existing microbubbles from dissolved air in the solution environment and within the organ, thereby eliminating their interference with imaging. The degassing procedure used a membrane pump to directly pump38 above the PET sample jar with the lid open in a sealed vacuum glass dryer. Prior to imaging, the PET jar containing the lung, ethanol solution, and agar embedding was placed in a custom-made sample holder to connect to the rotation stage at the synchrotron beamline26.

Synchrotron X-ray imaging and reconstruction

The implementation and capabilities of HiP-CT have been described in detail in a separate publication26. Here, we describe the settings used for lung imaging. All X-ray imaging experiments were carried out at the ESRF bending magnet beamline BM0539. The polychromatic synchrotron beam produced at the beamline was passed through a set of filters and then directly used for imaging without additional X-ray optics. The voxel size is effectively controlled by the adjustable visible-light imaging optics situated after the LuAG:Ce (cerium-doped lutetium aluminium garnet) X-ray scintillator (custom-made by Crytur, Czechia) and before the sCMOS (scientific complementary metal-oxide-semiconductor) light sensor (PCO edge 4.2 CLHS, PCO Imaging, Germany). Specifically, the imaging optics include the dzoom (“demagnifying zoom”) and zoom lenses, which cover the ranges of 6.5–25.5 μm and 1.3–6.3 μm, respectively. Because the synchrotron beam size (with usable area 50 mm × 4 mm at BM05) is considerably smaller than the size of the human left lung (container size 260 mm height, up to 140 mm width at the widest), imaging the entire left lung at 25.08 μm voxel size required stitching together multiple subscans. We used the half-acquisition (or half-object acquisition)40 method developed at ESRF for imaging the VOIs at 6.5 μm and 2.5 μm in voxel size. For the entire lung, we developed a quarter-acquisition method26 that includes the half-acquisition in combination with an annular scan to cover its complete horizontal extent (see Fig. 2).

Fig. 2.

Fig. 2

Synchrotron-based hierarchical phase-contrast tomography (HiP-CT) at multiple lengthscales and their associated data acquisition and image reconstruction pipelines. The full-field tomography data at 25.08 μm voxel size are processed with pipeline (a). The local tomography data for volumes of interest (VOIs) at 6.05–6.5 μm (level 1) and 2.45–2.5 μm (level 2) voxel size are processed with pipeline (b). (c) A schematic illustrating the relationships of the various cylindrical volumes imaged with HiP-CT. The triple arrows in the pipeline before merging the subscans indicate that the same procedure is carried out on each subscan.

Data processing of the measured X-ray projections consists of three stages, pre-reconstruction, reconstruction and post-reconstruction, which are illustrated in separate rows in Fig. 2. Ring artifacts from the detectors are corrected in two steps: (1) Before reconstruction, the mean of the projections is subtracted from the projections to remove the rings with constant intensity rings; (2) After reconstruction, the residual inhomogeneous intensity rings were removed using the polar transform combined with linear motion blurring filter41. Tomographic reconstruction employs the phase and amplitude estimates obtained from Paganin’s method42, followed by a 2D unsharp mask of the retrieved phase maps as input for the filtered backprojection algorithm. These reconstruction steps are implemented in PyHST243. Eventually, the processed volumes are converted to a 16-bit format and binned further to produce the datasets described in Tables 23. The reconstruction and postprocessing steps are illustrated for the three types of imaged sample volumes, respectively, in Fig. 2. We summarize below the imaging and reconstruction protocols for the human lung at each imaged resolution including the key parameters.

  • Full-field tomography (the whole organ at 25.08 μm voxel size, see Fig. 2a,c): The detected X-ray energy averaged at ~93 keV after filters and sample, the propagation distance was 3475 mm, the scintillator thickness was 2 mm. In total, two sets of 9990 projections were measured by the quarter-acquisition method26 with an offset of 800 pixels for the half-acquisition. A step size of 2.2 mm in the vertical (z) direction was used to cover the height of the sample jar with a total of 98 quarter-acquisition subscans. Radiographic stitching was first carried out to recover a half-acquisition scan40 before the reconstruction.

  • Local tomography of level 1 VOI (6.5 μm and 6.05 μm voxel size, see Fig. 2b,c): The detected X-ray energy averaged at ~88 keV (~89 keV) after filters and sample, the propagation distance was 3500 mm (3475 mm), the scintillator thickness was 1 mm (2 mm) for the VOIs with 6.5 μm (6.05 μm) voxel size. In total, 6000 projections were measured by the half-acquisition method with an offset of 900 pixels. A step size of 2.2 mm in the vertical direction was used to cover the height of the VOIs.

  • Local tomography of level 2 VOI (2.5 μm and 2.45 μm voxel size, see Fig. 2b,c): The detected X-ray energy averaged at ~77 keV (~79 keV) after filters and sample, the propagation distance was 1440 mm (1500 mm), the scintillator thickness was 0.25 mm (0.2 mm) for the VOIs with 2.5 μm (2.45 μm) voxel size. In total, 6000 projections were measured by the half-acquisition method with an offset of 900 pixels. A step size of 1.5 mm in the vertical direction was used to cover the height of the VOIs.

Table 2.

Volumes of interest and their anatomical references to the whole human left lung sample.

VOI reference Height (mm) Diameter (mm) Volume (mL) Displacement (mm) Z-axis rotation Anatomical reference
6.5 µm, VOI1 48.79 25.06 24.1 (23.3, −9.4, −81.2) 24.6° upper lobe, apical region
6.5 µm, VOI2b 26.74 25.05 13.2 (5.8, −15.0, −26.5) 24.6° upper lobe, medial region
6.5 µm, VOI3b 9.11 25.04 4.49 (5.5, 0.8, −15.2) 24.6° interlobar fissure
6.5 µm, VOI4b 106.07 25.06 53.2 (−20.6, 8.1, 37.1) 24.6° lower lobe, basal to medial region
6.5 µm, VOI5 59.81 25.04 29.5 (−3.3, −15.1, −71.0) 24.6° upper lobe, apical region
6.05 µm, VOI1 7.61 23.12 3.19 (−12.5, −23.5, −67.9) upper lobe, apical region
6.05 µm, VOI2 42.17 23.1 17.7 (−7.0, 11.4, 65.5) lower lobe, basal region
6.05 µm, VOI6 48.85 23.09 20.5 (−19.3, −4.9, 59.7) lower lobe, basal region
2.5 µm, VOI1 32 9.69 2.36 (18.4, −19.5, −84.5) 24.6° upper lobe, apical region
2.5 µm, VOI2b 14 9.7 1.03 (0.3, −20.7, −83.6) 24.6° upper lobe, apical region
2.5 µm, VOI3 14 9.69 1.03 (−12.6, −24.6, −65.7) 24.6° upper lobe, apical region
2.5 µm, VOI4 14 9.69 1.03 (20.5, −19.0, −43.0) 24.6° upper lobe, medial region
2.5 µm, VOI5 38.25 9.67 2.81 (−22.1, 6.4, 63.5) 24.6° lower lobe, basal region
2.45 µm, VOI1 8.52 9.33 0.582 (−12.6, −23.7, −67.5) 4.8° upper lobe, apical region
2.45 µm, VOI2 11.93 9.33 0.816 (−7.7, 12.0, 63.0) lower lobe, basal region
2.45 µm, VOI6 4.9 9.33 0.335 (−19.3, −4.9, 65.1) lower lobe, basal region

Table 3.

Details of the hierarchical X-ray phase-contrast tomography data for a human left lung.

Folder name (.zip) Binning Image size Voxel size (µm3)
25.08um_LADAF_2020-27_lung-left_pag-0.11_0.25_jp2_ 1 5984 × 5984 × 8720 25.083
50.16um_LADAF_2020-27_lung-left_pag-0.11_0.25_jp2_ 2 2992 × 2992 × 4360 50.163
100.32um_LADAF_2020-27_lung-left_pag-0.11_0.25_jp2_ 4 1496 × 1496 × 2180 100.323
6.5um_LADAF-2020-27_lung-left_VOI-01_pag-0.07_0.43_jp2_ 1 3856 × 3856 × 7506 6.53
13um_LADAF-2020-27_lung-left_VOI-01_pag-0.07_0.43_jp2_ 2 1928 × 1928 × 3753 13.03
6.5um_LADAF-2020-27_lung-left_VOI-02b_pag-0.12_0.45_jp2_ 1 3854 × 3854 × 4114 6.53
13um_LADAF-2020-27_lung-left_VOI-02b_pag-0.12_0.45_jp2_ 2 1928 × 1928 × 3753 13.03
6.5um_LADAF-2020-27_lung-left_VOI-03b_pag-0.12_0.46_jp2_ 1 3852 × 3852 × 1402 6.53
13um_LADAF-2020-27_lung-left_VOI-03b_pag-0.12_0.46_jp2_ 2 1926 × 1926 × 701 13.03
6.5um_LADAF-2020-27_lung-left_VOI-04b_pag-0.12_0.46_jp2_ 1 3856 × 3856 × 16318 6.53
13um_LADAF-2020-27_lung-left_VOI-04b_pag-0.12_0.46_jp2_ 2 1928 × 1928 × 8159 13.03
6.5um_LADAF-2020-27_lung-left_VOI-05_pag-0.08_0.43_jp2_ 1 3852 × 3852 × 9202 6.53
13um_LADAF-2020-27_lung-left_VOI-05_pag-0.08_0.43_jp2_ 2 1926 × 1926 × 4601 13.03
6.05um_LADAF-2020-27_lung-left_VOI-01_pag-0.01_0.03_jp2_ 1 3822 × 3822 × 1258 6.053
12.1um_LADAF-2020-27_lung-left_VOI-01_pag-0.01_0.03_jp2_ 2 1911 × 1911 × 629 12.13
6.05um_LADAF-2020-27_lung-left_VOI-02_pag-0.01_0.19_jp2_ 1 3818 × 3818 × 6970 6.053
12.1um_LADAF-2020-27_lung-left_VOI-02_pag-0.01_0.19_jp2_ 2 1909 × 1909 × 3485 12.13
6.05um_LADAF-2020-27_lung-left_VOI-06_pag-0.02_0.25_jp2_ 1 3816 × 3816 × 8074 6.053
12.1um_LADAF-2020-27_lung-left_VOI-06_pag-0.02_0.25_jp2_ 2 1908 × 1908 × 4037 12.13
2.5um_LADAF-2020-27_lung-left_ROI-01_pag-0.02_0.25_jp2_ 1 3878 × 3878 × 12802 2.53
5um_LADAF-2020-27_lung-left_ROI-01_pag-0.02_0.25_jp2_ 2 1939 × 1939 × 6401 5.03
2.5um_LADAF-2020-27_lung-left_VOI-02b_pag-0.04_0.34_jp2_ 1 3880 × 3880 × 5600 2.53
5um_LADAF-2020-27_lung-left_VOI-02b_pag-0.04_0.34_jp2_ 2 1940 × 1940 × 2800 5.03
2.5um_LADAF-2020-27_lung-left_VOI-03_pag-0.02_0.04_jp2_ 1 3878 × 3878 × 5600 2.53
5um_LADAF-2020-27_lung-left_VOI-03_pag-0.02_0.04_jp2_ 2 1939 × 1939 × 2800 5.03
2.5um_LADAF-2020-27_lung-left_VOI-04_pag-0.02_0.29_jp2_ 1 3876 × 3876 × 5600 2.53
5um_LADAF-2020-27_lung-left_VOI-04_pag-0.02_0.29_jp2_ 2 1938 × 1938 × 2800 5.03
2.5um_LADAF-2020-27_lung-left_VOI-05_pag-0.02_0.24_jp2_ 1 3868 × 3868 × 15300 2.53
5um_LADAF-2020-27_lung-left_VOI-05_pag-0.02_0.24_jp2_ 2 1934 × 1934 × 7650 5.03
2.45um_LADAF-2020-27_lung-left_01_pag-0.03_0.05_jp2_ 1 3816 × 3816 × 3478 2.453
4.9um_LADAF-2020-27_lung-left_01_pag-0.03_0.05_jp2_ 2 1908 × 1908 × 1739 4.93
2.45um_LADAF-2020-27_lung-left_02_pag-0.02_0.06_jp2_ 1 3810 × 3810 × 4868 2.453
4.9um_LADAF-2020-27_lung-left_02_pag-0.02_0.06_jp2_ 2 1905 × 1905 × 999 4.93
2.45um_LADAF-2020-27_lung-left_06_pag-0.02_0.04_jp2_ 1 3810 × 3810 × 1998 2.453
4.9um_LADAF-2020-27_lung-left_06_pag-0.02_0.04_jp2_ 2 1905 × 1905 × 999 4.93

Volume selection and anatomical reference

Besides the full-field tomography of the entire lung, subsequent smaller VOIs were selected with representative features and imaged with local tomography at higher resolution, including 6.5 μm (5 locations) and 6.05 μm (3 locations) for level 1 and 2.5 μm (5 locations) and 2.45 μm (3 locations) for level 2 VOIs, respectively. All VOIs have a cylindrical field of view around the rotation axis after removing the boundary artifacts from the local tomographic reconstruction. To obtain the displacements and rotations, the VOIs are spatially registered to the whole lung data by hand in VGStudio Max (version 3.4) and the procedure to apply them is described in Usage Notes. The sizes of the VOIs, their displacements, and rotations with respect to the center of the whole lung data are listed in Table 2 and illustrated in Fig. 3a–d. In addition, we provide brief anatomical references to the VOI spatial locations in Table 2 with respect to the whole lung data at 25.08 μm. To retain traceable data provenance, we keep the same alphanumeric labels of the VOIs as used in the original experiments. Figure 3e visualizes two selected VOIs in the lower lobe of the lung.

Fig. 3.

Fig. 3

Exploration of the HiP-CT dataset of a human left lung. (ad) Spatial correspondences of the measured cylindrical VOIs at different resolutions within the entire left lung. For each set of VOIs, both the medial (left) and sagittal (right) views are shown. The VOI label corresponds to the assignment in Table 2. (e) Renderings of two imaged VOIs with 6.5 μm and 2.5 μm voxel sizes, respectively. (f) From the whole lung and local tomography data, we visualize the anatomical detail of a partially calcified, spiculated lung nodule in the apical region of the lung on multiple lengthscales. The interlobular septa and perilobular vasculature of the secondary pulmonary lobules (SPLs) are depicted.

Data Records

We provide the volumetric data after reconstruction and post-processing as greyscale (16-bit) 2D image slices in the JPEG2000 format stored in zipped folders. The compression level of JPEG2000 is carefully chosen to ensure minimal difference from the original TIFF-formatted data when they are used for feature quantification or image segmentation. We list the details of the deposited data in Table 3. All data have been deposited at an ESRF data repository (https://human-organ-atlas.esrf.eu/explore/LADAF-2020-27/left%20lung) with digital object identifiers (DOIs) assigned to each scanned volume as listed in Table 4. Each DOI refers to a volume at full resolution and its binned versions. For all VOIs measured by local tomography, including those with voxel sizes of 6.5 μm4448, 6.05 μm4951, 2.5 μm5256, and 2.45 μm5759, both the full resolution data (Binning = 1) and the 2 × binned version (Binning = 2) are provided, while for the whole lung data60, the 4 × binned version (Binning = 4) is also provided. The metadata information in Table 2 is also provided in the corresponding text file contained in each data deposit. The landing page associated with each DOI contains extended information on the parameters of the X-ray beamline for phase-contrast tomography, experimental scanning protocol, and data processing procedures.

Table 4.

Information about the data records.

Data description Index Reference
Full-field tomography data at 25.08 µm voxel size and binned versions (50.16 µm, 100.32 µm voxel sizes) 60
Local tomography data at 6.5 µm voxel size and binned version (13.0 µm voxel size) VOI1 44
VOI2b 45
VOI3b 46
VOI4b 47
VOI5 48
Local tomography data at 6.05 µm voxel size and binned version (12.1 µm voxel size) VOI1 49
VOI2 50
VOI6 51
Local tomography data at 2.5 µm voxel size and binned version (5.0 µm voxel size) VOI1 52
VOI2b 53
VOI3 54
VOI4 55
VOI5 56
Local tomography data at 2.45 µm voxel size and binned version (4.9 µm voxel size) VOI1 57
VOI2 58
VOI6 59

Technical Validation

Although the radiation dose in HiP-CT scans is well below the tissue damage threshold26, due to radiation-induced bubble formation, which only appeared after multiple high-resolution, local tomography scans, the sample went through re-degassing before the remaining measurements were made. The bubbles largely come from solvent vaporization61 but don’t cause visible radiation damage as shown by histology26. However, a consequence of re-degassing is that not all of the VOIs have been imaged consecutively during the same beamtime. In the course of re-degassing, the sample was kept in the container to maintain its original position. The sample jar was then placed into the synchrotron X-ray beamline for further imaging. During the process, care was exercised such that the VOIs scanned before and after re-degassing can be registered to the whole volume without large deformation.

In the imaged volumes, contrast is produced by the local density differences between the lung tissue constituents and the void spaces of the airways, alveoli, and blood vessels filled with ethanol solution (see Fig. 3e,f). Within the whole lung data at a voxel size of 25.08 μm, the interlobular septa, the boundaries of the secondary pulmonary lobules62,63 and the perilobular vasculature, are clearly visible (see Fig. 3f). At high spatial resolution, the local density difference increasingly becomes the dominant contributor to image contrast in VOIs26. The consistent contrast across lengthscales provides detailed information for the study of lung morphology for the healthy individual or as a control.

Regarding the total lung capacity for the individual, postmortem estimation is severely hampered by (1) the inability to directly measure anatomical dead space and (2) complex functional interactions between skeletal thorax, diaphragm configuration or tonus and pleural space, which are not reconstructible postmortem. Nevertheless, since the lung was inflated with near-normal pressure at fixation, our best assumption for near-normal inspiration inflation is pressure-controlled inflation. In addition, despite the great efforts in maintaining the integrity of the organ during preparation and scanning, in some subpleural areas of the lung, we have noticed a slight compression. We attribute the potential causes of these features to the following: (1) The formalin used in fixation may have difficulties in reaching the more peripheral lung areas. (2) The tight fit of the agar blocks around the lung. (3) A sign of minimal parabronchial and/or subpleural emphysema due to aging5.

Usage Notes

The multiscale healthy human lung data presented here have been used as clinical control data in studies comparing damage within the lung microstructure due to Covid-19 infection26. The individual VOIs are deposited as 2D image slices perpendicular to the rotation axis (z in Fig. 1) in the tomography geometry. These images may be directly loaded into any typical image processing software for viewing or further quantification. To align the VOIs to the whole lung data, the following transform should be applied to the VOI,

I(x,y,z)=T(dx,dy,dz)Rz(θz)I(x,y,z). 1

Here I' and I are intensity-valued volumetric data, T is the 3D translation operator, and Rz the 3D rotation operator around the z axis (see Fig. 1b,c). The displacement vector (dx, dy, dz) and z rotation angle θz for each VOI is listed in Table 2. The default greyscale ranges of the images are set with an intensity margin to avoid saturation. Viewing directly by eye may require threshold adjustment.

Acknowledgements

We thank S. Bayat (INSERM), P. Masson (LADAF) for extracting the lung from the body donor, H. Reichert (ESRF) and R. Torii (UCL) for general support of the project, and C. Muzelle, R. Homs, C. Jarnias, F. Cianciosi, P. Vieux, P. Cook, L. Capasso and A. Mirone for their help in the X-ray imaging setup developments and improvements. We thank A. de Maria, A. Bocciarelli, M. Bodin, J.-F. Perrin, and A. Goetz at ESRF for support on the Human Organ Atlas database. The authors also thank C. Werlein, R. Engelhardt, A. M. Brechlin, C. Petzold and N. Kroenke. This project has been made possible in part by grants number 2020-225394 from the Chan Zuckerberg Initiative DAF, an advised fund of Silicon Valley Community Foundation, The ESRF - funding proposal md1252, the Royal Academy of Engineering (PDL - CiET1819/10) and the MRC (MR/R025673/1). M.A. acknowledges grants from the National Institutes of Health (HL94567 and HL134229). D.D.J. acknowledges the European Consolidator Grant, XHale (ref. no. 771883). J.J. acknowledges Wellcome Trust Clinical Research Career Development Fellowship 209553/Z/17/Z and the National Institute for Health Research University College London Hospital Biomedical Research Centre. This research was funded in whole, or in part, by the Wellcome Trust [209553/Z/17/Z]. For the purpose of open access, the author has applied a CC-BY public copyright licence to any Author Accepted Manuscript version arising from this submission.

Author contributions

P.D.L. and P.T. conceived the experiment. P.D.L., C.L.W. and P.T. coordinated the collaboration. A.B. harvested the lung from the body donor and prepared the lung for imaging along with P.T. . S.M. designed the sample holder for organ imaging. P.T. conducted the imaging experiment at ESRF BM05 beamline and reconstructed the volumetric data. R.P.X. analyzed the data with help and instructions from P.T., S.V., W.L.W., J.J., M.A. and D.D.J. . R.P.X. wrote the first version of the manuscript. All authors reviewed and discussed the manuscript to bring it to the final form.

Code availability

The code used for the preprocessing, tomographic reconstruction, and postprocessing is available on GitHub (https://github.com/HiPCTProject/Tomo_Recon).

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

These authors contributed equally: R. Patrick Xian, Paul Tafforeau.

Contributor Information

R. Patrick Xian, Email: rp.xian@ucl.ac.uk.

Peter D. Lee, Email: peter.lee@ucl.ac.uk

Paul Tafforeau, Email: paul.tafforeau@esrf.fr.

References

  • 1.Weibel, E. R. Morphometry of the Human Lung (Springer Berlin Heidelberg, Berlin, Heidelberg, 1963).
  • 2.Ochs M, et al. The Number of Alveoli in the Human Lung. American Journal of Respiratory and Critical Care Medicine. 2004;169:120–124. doi: 10.1164/rccm.200308-1107OC. [DOI] [PubMed] [Google Scholar]
  • 3.Katsamenis OL, et al. X-ray Micro-Computed Tomography for Nondestructive Three-Dimensional (3D) X-ray Histology. The American Journal of Pathology. 2019;189:1608–1620. doi: 10.1016/j.ajpath.2019.05.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Vasilescu DM, et al. Comprehensive stereological assessment of the human lung using multiresolution computed tomography. Journal of Applied Physiology. 2020;128:1604–1616. doi: 10.1152/japplphysiol.00803.2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Verleden SE, et al. Small airway loss in the physiologically ageing lung: a cross-sectional study in unused donor lungs. The Lancet Respiratory Medicine. 2021;9:167–174. doi: 10.1016/S2213-2600(20)30324-6. [DOI] [PubMed] [Google Scholar]
  • 6.Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Physics in Medicine and Biology. 2013;58:R1–R35. doi: 10.1088/0031-9155/58/1/R1. [DOI] [PubMed] [Google Scholar]
  • 7.Endrizzi M. X-ray phase-contrast imaging. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2018;878:88–98. doi: 10.1016/j.nima.2017.07.036. [DOI] [Google Scholar]
  • 8.Ritman EL. Current Status of Developments and Applications of Micro-CT. Annual Review of Biomedical Engineering. 2011;13:531–552. doi: 10.1146/annurev-bioeng-071910-124717. [DOI] [PubMed] [Google Scholar]
  • 9.Liu JTC, et al. Harnessing non-destructive 3D pathology. Nature Biomedical Engineering. 2021;5:203–218. doi: 10.1038/s41551-020-00681-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Zhao S, et al. Cellular and Molecular Probing of Intact Human Organs. Cell. 2020;180:796–812.e19. doi: 10.1016/j.cell.2020.01.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Wagner WL, et al. Towards synchrotron phase-contrast lung imaging in patients – a proof-of-concept study on porcine lungs in a human-scale chest phantom. Journal of Synchrotron Radiation. 2018;25:1827–1832. doi: 10.1107/S1600577518013401. [DOI] [PubMed] [Google Scholar]
  • 12.Momose A. X-ray phase imaging reaching clinical uses. Physica Medica. 2020;79:93–102. doi: 10.1016/j.ejmp.2020.11.003. [DOI] [PubMed] [Google Scholar]
  • 13.Bilderback DH, Elleaume P, Weckert E. Review of third and next generation synchrotron light sources. Journal of Physics B: Atomic, Molecular and Optical Physics. 2005;38:S773–S797. doi: 10.1088/0953-4075/38/9/022. [DOI] [Google Scholar]
  • 14.Weckert E. The potential of future light sources to explore the structure and function of matter. IUCrJ. 2015;2:230–245. doi: 10.1107/S2052252514024269. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Ding, Y. et al. Computational 3D histological phenotyping of whole zebrafish by X-ray histotomography. eLife8, 10.7554/eLife.44898 (2019). [DOI] [PMC free article] [PubMed]
  • 16.Zdora M-C, et al. X-ray phase tomography with near-field speckles for three-dimensional virtual histology. Optica. 2020;7:1221. doi: 10.1364/OPTICA.399421. [DOI] [Google Scholar]
  • 17.Kuan AT, et al. Dense neuronal reconstruction through X-ray holographic nano-tomography. Nature Neuroscience. 2020;23:1637–1643. doi: 10.1038/s41593-020-0704-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Longo E, et al. X-ray Zernike phase contrast tomography: 3D ROI visualization of mm-sized mice organ tissues down to sub-cellular components. Biomedical Optics Express. 2020;11:5506. doi: 10.1364/BOE.396695. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Umetani K, Okamoto T, Saito K, Kawata Y, Niki N. 36M-pixel synchrotron radiation micro-CT for whole secondary pulmonary lobule visualization from a large human lung specimen. European Journal of Radiology Open. 2020;7:100262. doi: 10.1016/j.ejro.2020.100262. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Westöö C, et al. Distinct types of plexiform lesions identified by synchrotron-based phase-contrast micro-CT. American Journal of Physiology-Lung Cellular and Molecular Physiology. 2021;321:L17–L28. doi: 10.1152/ajplung.00432.2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Litzlbauer HD, et al. Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus. The Anatomical Record: Advances in Integrative Anatomy and Evolutionary Biology. 2010;293:1607–1614. doi: 10.1002/ar.21161. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Elfarnawany M, et al. Micro-CT versus synchrotron radiation phase contrast imaging of human cochlea. Journal of Microscopy. 2017;265:349–357. doi: 10.1111/jmi.12507. [DOI] [PubMed] [Google Scholar]
  • 23.Norvik C, et al. Synchrotron-based phase-contrast micro-CT as a tool for understanding pulmonary vascular pathobiology and the 3-D microanatomy of alveolar capillary dysplasia. American Journal of Physiology-Lung Cellular and Molecular Physiology. 2020;318:L65–L75. doi: 10.1152/ajplung.00103.2019. [DOI] [PubMed] [Google Scholar]
  • 24.Cunningham JA, Rahman IA, Lautenschlager S, Rayfield EJ, Donoghue PC. A virtual world of paleontology. Trends in Ecology & Evolution. 2014;29:347–357. doi: 10.1016/j.tree.2014.04.004. [DOI] [PubMed] [Google Scholar]
  • 25.Du M, et al. Upscaling X-ray nanoimaging to macroscopic specimens. Journal of Applied Crystallography. 2021;54:386–401. doi: 10.1107/S1600576721000194. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Walsh CL, et al. Imaging intact human organs with local resolution of cellular structures using hierarchical phase-contrast tomography. Nature Methods. 2021;18:1532–1541. doi: 10.1038/s41592-021-01317-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Busse M, et al. Three-dimensional virtual histology enabled through cytoplasm-specific X-ray stain for microscopic and nanoscopic computed tomography. Proceedings of the National Academy of Sciences. 2018;115:2293–2298. doi: 10.1073/pnas.1720862115. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Massimi L, et al. Exploring Alzheimer’s disease mouse brain through X-ray phase contrast tomography: From the cell to the organ. NeuroImage. 2019;184:490–495. doi: 10.1016/j.neuroimage.2018.09.044. [DOI] [PubMed] [Google Scholar]
  • 29.Porcier SM, et al. Wild crocodiles hunted to make mummies in Roman Egypt: Evidence from synchrotron imaging. Journal of Archaeological Science. 2019;110:105009. doi: 10.1016/j.jas.2019.105009. [DOI] [Google Scholar]
  • 30.Wittig NK, et al. Opportunities for biomineralization research using multiscale computed X-ray tomography as exemplified by bone imaging. Journal of Structural Biology. 2022;214:107822. doi: 10.1016/j.jsb.2021.107822. [DOI] [PubMed] [Google Scholar]
  • 31.Wälchli T, et al. Hierarchical imaging and computational analysis of three-dimensional vascular network architecture in the entire postnatal and adult mouse brain. Nature Protocols. 2021;16:4564–4610. doi: 10.1038/s41596-021-00587-1. [DOI] [PubMed] [Google Scholar]
  • 32.Raimondi P. ESRF-EBS: The Extremely Brilliant Source Project. Synchrotron Radiation News. 2016;29:8–15. doi: 10.1080/08940886.2016.1244462. [DOI] [Google Scholar]
  • 33.Rack A. Hard X-ray Imaging at ESRF: Exploiting Contrast and Coherence with the New EBS Storage Ring. Synchrotron Radiation News. 2020;33:20–28. doi: 10.1080/08940886.2020.1751519. [DOI] [Google Scholar]
  • 34.Wilke J, et al. Appraising the methodological quality of cadaveric studies: validation of the QUACS scale. Journal of Anatomy. 2015;226:440–446. doi: 10.1111/joa.12292. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Shirai R, et al. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography. Journal of Synchrotron Radiation. 2014;21:795–800. doi: 10.1107/S1600577514010558. [DOI] [PubMed] [Google Scholar]
  • 36.Patzelt M, et al. Ethanol fixation method for heart and lung imaging in micro-CT. Japanese Journal of Radiology. 2019;37:500–510. doi: 10.1007/s11604-019-00830-6. [DOI] [PubMed] [Google Scholar]
  • 37.Gamma Radiation Resistance: Definition & Values For Plastics. https://omnexus.specialchem.com/polymer-properties/properties/gamma-radiation-resistance.
  • 38.Luyckx G, Ceulemans J. Deoxygenation, Deaeration and Degassing: A Survey and Evaluation of Methods. Bulletin des Sociétés Chimiques Belges. 1987;96:151–163. doi: 10.1002/bscb.19870960214. [DOI] [Google Scholar]
  • 39.Ziegler, E. et al. The ESRF BM05 Metrology Beamline: Instrumentation And Performance Upgrade. In AIP Conference Proceedings, 705, 436–439, 10.1063/1.1757827 (AIP, 2004).
  • 40.Kyrieleis A, Ibison M, Titarenko V, Withers P. Image stitching strategies for tomographic imaging of large objects at high resolution at synchrotron sources. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2009;607:677–684. doi: 10.1016/j.nima.2009.06.030. [DOI] [Google Scholar]
  • 41.Lyckegaard A, Johnson G, Tafforeau P. Correction of ring artifacts in X-ray tomographic images. International Journal of Tomography and Statistics. 2011;18:1–9. [Google Scholar]
  • 42.Paganin D, Mayo SC, Gureyev TE, Miller PR, Wilkins SW. Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. Journal of Microscopy. 2002;206:33–40. doi: 10.1046/j.1365-2818.2002.01010.x. [DOI] [PubMed] [Google Scholar]
  • 43.Mirone A, Brun E, Gouillart E, Tafforeau P, Kieffer J. The PyHST2 hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 2014;324:41–48. doi: 10.1016/j.nimb.2013.09.030. [DOI] [Google Scholar]
  • 44.Tafforeau P, 2021. Zoom at 6.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 45.Tafforeau P, 2021. Zoom at 6.5um in the upper medial lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 46.Tafforeau P, 2021. Zoom at 6.5um in the interlobular fissure of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 47.Tafforeau P, 2021. Zoom at 6.5um in the lower lobe basal to medial of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 48.Tafforeau P, 2021. Zoom at 6.5um in the upper lobe apical of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 49.Tafforeau P, 2021. Zoom at 6.05um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 50.Tafforeau P, 2021. Zoom at 6.05um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 51.Tafforeau P, 2021. Zoom at 6.05um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 52.Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 53.Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 54.Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 55.Tafforeau P, 2021. Zoom at 2.5um in the upper medial lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 56.Tafforeau P, 2021. Zoom at 2.5um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 57.Tafforeau P, 2021. Zoom at 2.45um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 58.Tafforeau P, 2021. Zoom at 2.45um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 59.Tafforeau P, 2021. Zoom at 2.45um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 60.Tafforeau P, 2021. Complete left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  • 61.Prosperetti A. Vapor Bubbles. Annual Review of Fluid Mechanics. 2017;49:221–248. doi: 10.1146/annurev-fluid-010816-060221. [DOI] [Google Scholar]
  • 62.Bergin C, Roggli V, Coblentz C, Chiles C. The secondary pulmonary lobule: normal and abnormal CT appearances. American Journal of Roentgenology. 1988;151:21–25. doi: 10.2214/ajr.151.1.21. [DOI] [PubMed] [Google Scholar]
  • 63.Webb WR. Thin-Section CT of the Secondary Pulmonary Lobule: Anatomy and the Image—The 2004 Fleischner Lecture. Radiology. 2006;239:322–338. doi: 10.1148/radiol.2392041968. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Citations

  1. Tafforeau P, 2021. Zoom at 6.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  2. Tafforeau P, 2021. Zoom at 6.5um in the upper medial lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  3. Tafforeau P, 2021. Zoom at 6.5um in the interlobular fissure of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  4. Tafforeau P, 2021. Zoom at 6.5um in the lower lobe basal to medial of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  5. Tafforeau P, 2021. Zoom at 6.5um in the upper lobe apical of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  6. Tafforeau P, 2021. Zoom at 6.05um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  7. Tafforeau P, 2021. Zoom at 6.05um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  8. Tafforeau P, 2021. Zoom at 6.05um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  9. Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  10. Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  11. Tafforeau P, 2021. Zoom at 2.5um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  12. Tafforeau P, 2021. Zoom at 2.5um in the upper medial lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  13. Tafforeau P, 2021. Zoom at 2.5um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  14. Tafforeau P, 2021. Zoom at 2.45um in the upper apical lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  15. Tafforeau P, 2021. Zoom at 2.45um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  16. Tafforeau P, 2021. Zoom at 2.45um in the lower basal lobe of the left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]
  17. Tafforeau P, 2021. Complete left lung from the body donor LADAF-2020-27. In Human Organ Atlas. [DOI]

Data Availability Statement

The code used for the preprocessing, tomographic reconstruction, and postprocessing is available on GitHub (https://github.com/HiPCTProject/Tomo_Recon).


Articles from Scientific Data are provided here courtesy of Nature Publishing Group