Abstract
A flexible sinusoidal-shaped antenna sensor is introduced in this work, which is a modified half-wave dipole that can be used for strain sensing applications. The presented antenna is an improved extension of the previously introduced antenna sensor for respiration monitoring. The electrical and radiative characteristics of the sinusoidal antenna and the effects of the geometrical factors are studied. An approach is provided for designing the antenna, and equations are introduced to estimate the geometrical parameters based on desired electrical specifications. It is shown that the antenna sensor can be designed to have up to 5.5 times more sensitivity compared to the last generation of the antenna sensor previously introduced for respiration monitoring. The conductive polymer material used to fabricate the new antenna makes it more flexible and durable compared to the previous generation of antenna sensors made of glass-based material. Finally, a reference antenna made of copper and an antenna sensor made of the conductive polymer are fabricated, and their electrical characteristics are analyzed in free space and over the body.
Keywords: dipole antenna, miniaturized antenna, sinusoidal antenna, strain sensor, tunable antenna, conductive polymer, antenna sensor
1. Introduction
The electrical and radiative characteristics of antennas are functions of their geometrical structure and the material specifications of the conductors and dielectrics in the antenna’s vicinity [1]. Consequently, antennas can be exploited for sensing applications, where the geometrical deformations or material changes can be detected by monitoring the antenna’s radiative and electrical characteristics. Applications of antenna sensors can be in body movement capturing for computer animation or robot controlling, monitoring structural deformations, such as tracking cracks and displacements in buildings, monuments, and similar structures, and most importantly, monitoring vital signals for diagnosis and rehabilitation [2,3,4,5,6]. A Serpentine meshed patch antenna is reported for stretch strain sensing fabricated using laser-cut conductive textiles on Ecoflex substrate [7]. Recently, an RFID-incorporated meandered line dipole antenna in Ecoflex has also been reported to detect stretching strain [8].
In addition, some recently published works are focused on detecting bending strain. For example, Graphene-based patch antennas are introduced in recent works for detecting bending strain with applications in identifying human posture and joint movements [9,10]. An aluminum tape patch over a cellulose substrate is also reported in another work for bending strain detection. The use of cellulose makes the antenna recyclable and suitable to employ in disposable electromechanical sensors [11]. Some other works are focused on structural health monitoring (SHM) applications. Recent works in this area are in the form of rectangular [12], circular [13], and folded patch antennas [14]. Fractal-shaped patch antennas are also studied by Herbko and Lopato for a more miniaturized SHM antenna sensor [15]. More recently, a novel metamaterial-based SHM antenna sensor was also reported by the same team using a double split-ring resonator (dSRR) structure to achieve even more miniaturization while increasing the strain sensitivity [16].
Antenna sensors can also be embedded in wearables for vital signal monitoring applications. Although many sensing technologies have been developed for monitoring vital signals [17,18], applying on-body antenna sensors for this purpose is a relatively new field of study. A spiral-shaped flexible dipole antenna was reported for respiration detection by analyzing the received signal strength indicator (RSSI) of a Bluetooth connection [2]. Recently, a low-profile fully textile patch antenna was proposed for respiration monitoring applications [19]. A new antenna sensor in the form of a fully embroidered meander line dipole was also proposed in a recent work for real-time respiration monitoring [20].
This work presents a flexible sinusoidal-shaped half-wave dipole antenna sensor that can be used in strain sensing and vital signal monitoring applications. The proposed sinusoidal antenna sensor is the new generation of a previously introduced antenna sensor for respiration monitoring [2]. Using flexible conductors as antenna material, the changes in the antenna’s impedance due to the mechanical compressions or stretchings can be picked up by a measurement device as an indicator of the strain applied to the antenna [4]. It is shown that the antenna sensor introduced in this paper could be up to 5.5 times more sensitive than the previous generation [2].
The sinusoidal antenna introduced in this paper is a modified version of the half-wave dipole antenna. Modified dipoles are reported and studied in the literature for the sake of miniaturization and impedance control, such as meandered, zigzag [21,22,23,24], and monopole sinusoidal geometries [25,26]. They are also employed in Log Periodic Dipole Array (LPDA) antennas [27,28] and Radio frequency identification (RFID) tags [29,30] due to their short axial length. Similarly, the sinusoidal antenna introduced here has a resonant impedance lower than the traditional straight dipole antenna and an axial length shorter than . For example, a sinusoidal antenna designed for is 20% axially shorter than a traditional straight half-wave dipole. The miniature size of the sinusoidal antenna makes it suitable for wearable applications.
Our implemented antenna sensor for vital signal monitoring is designed to be placed over the front of the chest area and embedded in a T-shirt [4]. This method of vital signal monitoring is different from non-contact systems, where both antenna and the measurement and detection system are located remotely from the subject [17]. The changes in the circumference of the upper body may lead to a geometrical deformation of the wearable antenna sensor, which changes its radiative and electrical characteristics, which will be detected by a measurement system. Sensitivity to strain, stretchability, flexibility, and durability are crucial factors for achieving a viable vital signal sensing system, as well as the Specific Absorption Rate (SAR) since these antenna sensors are placed over the body.
In the light of these requirements, this paper paves the way for realizing a vital signal monitoring system with a more sensitive, flexible, durable, and miniaturized antenna sensor compared to the previous generation [2,3,4]. A detailed study of the sinusoidal antenna’s radiative and electrical specifications for various configurations is provided, its sensitivity to deformations is studied, and a design guide is provided for the antenna sensor. Finally, a prototype antenna is fabricated and measured in free space and over the body, and its durability and SAR compliance are studied. An upcoming paper will cover the antenna’s application in a vital signal monitoring system and provide measurement data for the antenna sensor.
The sinusoidal antenna is introduced and studied in detail in the second and third sections of this paper. The antenna is simulated using CST Studio Suite® 2020 software [31], and the effects of the geometrical parameters are analyzed on its radiation characteristics and strain sensitivity. A design guide is provided in the fourth section using two methods, and equations are introduced for estimating the geometrical parameters based on desired characteristics. In the fifth section, a reference copper antenna and a flexible polymer antenna sensor are fabricated, their electrical parameters are measured, and their environmental durability is analyzed through an experiment. Discussions are made in the sixth section about the antenna’s SAR, its behavior under bending and twisting, and its application in strain sensing. Additionally, a summary of the state-of-the-art is provided, and it is shown that higher sensitivity to strain is achievable using this antenna sensor compared to the traditional design used in our previous work, known as a half-turn Archimedean spiral antenna [2].
2. Antenna Geometry
The design of the antenna sensor, shown in Figure 1, is based on the traditional straight half-wave dipole. The antenna wires are bent times to form a sinusoidal shape in the domain of zero to . Equation (1) can be considered for plotting the shape of a single pole of the antenna in a cartesian coordinate system where parameters and define the width and the length of the antenna, respectively. The factor indicates the number of extrema in the structure of a single antenna pole.
(1) |
3. Specifications and Intrinsic Parameters
A straight half-wave dipole antenna has a total wire length of relative to its wavelength of operation, and ideally has an inductive impedance of on the respective frequency [32]. For the modified half-wave dipole antennas, the Shortening Ratio () is defined as the ratio between the reduction in its axial length and its total wire length, which is shown as [21,25,26]:
(2) |
The antenna introduced here is simulated using CST Studio Suite® 2020 full-wave electromagnetic simulation software [31]. The antenna is modeled by very thin wires made of Perfect Electric Conductor (PEC) and with a diameter of less than as an approximation of an infinitesimally thin antenna [1]. A feeding point gap of is considered to keep it as small as possible. The model details mentioned here are considered for all of the simulations presented in this work.
A set of calculations are made on the introduced antenna geometry for , in which the is increased in fine steps while keeping wire length () constant, as shown in Figure 2. The antenna’s width has to increase in each step to ensure the constancy of the wire length. The simulation results are presented in Figure 3. The antenna’s resonance frequency is normalized to the resonance frequency of the straight half-wave dipole (). It is evident that the more the antenna becomes compressed, the lower the radiation resistance on resonance, but the higher the resonance frequency.
3.1. Radiation Resistance
The decrease of radiation resistance due to the increase of seen in Figure 3a is expected behavior. To analyze the radiation resistance, we need to observe the antenna from a far-field point of view, with a distance of from the antenna, where . With the assumption of , the oscillations of the sinusoidal shape can be ignored from a far-field standpoint. Therefore, the antenna can be approximated as a straight dipole with a physical length of which is less than half of the operation wavelength. The antenna seen from the far-field is electrically shorter than a half-wave dipole. The real part of its impedance, indicating the radiation resistance, will be less than which is expected to become even smaller as it becomes a shorter dipole [1,21].
3.2. Resonance Frequency
The normalized resonance frequency of the antenna is shown in Figure 3b as a function of for the different number of bents ( parameter). The point is equivalent to a straight half-wave dipole , and therefore the simulation results show a resonance at around and a normalized frequency of unity. While the wire length is kept constant, the resonance frequency increases as the rises, which means that the rise of peaks and dips in antenna geometry causes an extra capacitive effect on the antenna [21].
3.3. Effects of the Factor
It can be concluded from Figure 3a that the higher the factor, the shorter the axial length of the antenna for specific radiation resistance, making it more miniaturized. Additionally, the antenna’s sensitivity to the deformations becomes more significant by choosing higher values.
In the case of , the antenna becomes so wide that it violates the assumption of and cannot be categorized as a linear dipole antenna from a far-field point of view. For example, the required designs to achieve using and are shown in Figure 4. The width of the antenna is noticeably large and around , which is violating . Consequently, by choosing , the antenna cannot be approximated with a linear equivalent antenna from the far-field point of view anymore. The antenna would virtually become a superposition of two perpendicular equivalent dipoles with specifications out of this work’s context.
3.4. Radiation Pattern and Maximum Gain
The radiation patterns of antennas designed for are illustrated in Figure 5. The antennas designed with the constraints of have a radiation pattern similar to a straight half-wave dipole. The maximum gain and Half-power beamwidth (HPBW) are presented in Table 1 for a straight half-wave dipole antenna () and sinusoidal antennas and . It can be concluded that a larger makes the antenna more similar to the straight half-wave dipole antenna in terms of HPBW and far-field pattern. The HPBW is slightly wider than the straight dipole in lower values and becomes narrower as rises, resulting in more directivity () and maximum gain (), as [1]. Following the discussion above about the effects of the factor, it can be seen that the unusual radiation pattern for the case of an antenna resembles a superposition of two dipoles along the Z- and Y-axis due to its noticeably large width of .
Table 1.
Max Gain (dBi/dBd) |
HPBW |
HPBW |
|
---|---|---|---|
0 * | 2.14/0 | 78° | 78° |
1 | 2.419/0.269 | 89.6° | 82.6° |
3 | 2.451/0.301 | 79.2° | 80.6° |
5 | 2.467/0.317 | 78.5° | 79.7° |
7 | 2.474/0.324 | 78.3° | 80.1° |
* Indicates traditional straight half-wave dipole.
4. Design Methods
Here a set of curve fittings are made of the simulation data to provide equations based on geometrical parameters for estimating the impedance on resonance and the resonance frequency of the sinusoidal antenna, which can provide a starting point for fine-tuning the antenna parameters. Two methods are presented, based on two constraints of fixed wire length or fixed axial length, and the pros and cons of each are described. The curve fittings are made through a Nonlinear Least Squares (NLS) method based on the Trust Region algorithm [33].
4.1. Method 1: Designing Based on for a Known
4.1.1. Curve Fittings Based on
In the data presented in Figure 3, the radiation characteristics are expressed based on which is the antenna length relative to the fixed total wire length . According to the curve fittings, the resonance frequency increases with the rise of , and the slope is proportional to the square root of . It can be written in the following form:
(3) |
where is the resonance frequency of a straight half-wave dipole with a length of . The impedance on resonance drops as increases, and the drop rate is approximately proportional to the 8th root of . Therefore, it can be fitted on the following form:
(4) |
By choosing in Equation (3), and in Equation (4), an of and is achieved for each Equation, respectively, as a measure of goodness-of-fit [34]. The curve fitting is made of the data in the domain of and . The precision of the curve fittings is shown in Figure A1 in Appendix A. It is also possible to choose a or of choice and solve the introduced equations for . It should be noted that factor can only take integer values and should be chosen according to the fabrication capabilities.
4.1.2. The Design Steps Using Method 1
Choosing a wire length and
Calculating for different values, or calculate for a given
Calculating for the chosen in step 2
Readjusting (and subsequently updating ) while keeping fixed to reach the desired resonance frequency
Calculating based on the finalized and using the integral Equation introduced in the following.
Verify the design by simulating the antenna model based on Equation (1)
Finish if the desired frequency is acquired; otherwise, repeat from Step 4.
It is worth mentioning that the designer has to redo all the steps if they decide to choose another value.
4.1.3. Calculating Antenna width
With and as known variables, calculating the width of the antenna () requires solving an integral equation. A small arc can be fit on the hypotenuse of a right triangle. According to the Pythagorean theorem, its length can be written as . By integrating over the curve, the total curve length can be calculated as follows:
(5) |
By combining (1) and (5), the wire length can be calculated as the following:
(6) |
4.1.4. Disadvantages of Method 1 Based on
The integral in Equation (6) does not have an elementary antiderivative and is an elliptic integral of the second kind. Even though numerical methods and software packages such as MATLAB can be used to solve the integral Equation for effortlessly [35,36], it would not be a convenient method in the antenna design synthesis process, especially if the design needs to be made based on antenna width parameter.
Although the definition of could help to understand the behavior of the antenna, it is not a decent choice for providing a design method since its dependency on constant wire length requires solving Equation (6) for before each iteration of the simulation to obtain the full geometrical parameters of the antenna. Additionally, the designer has to redo all the design steps in the case they decide to go with another value of . Moreover, the estimation of using Equation (4) based on cannot differentiate well between adjacent values since the data lines are very close.
4.2. Method 2: Designing Based on for a Known
4.2.1. Widening Ratio
Widening Ratio () is presented in Equation (7) for studying the antenna characteristics directly based on the geometric parameters of and and alleviate the need for solving the integral equations during the antenna design process.
(7) |
A new set of simulations were performed on antennas with different values while keeping constant and ignoring the assumption of fixed total wire length . This definition is beneficial while modeling the antenna based on and in electronic design automation (EDA) software and electromagnetic simulators. Figure 6 shows an example representation of the simulated model configurations for . This set of simulations are repeated for different values, and the results are presented in Figure 7.
4.2.2. Curve Fittings Based on
According to the data presented in Figure 7, the decrease in and is approximately proportional to and , and Equations (8) and (9) are provided based on this observation. These equations provide approximations for a given and , as a starting point for fine-tuning. In this Equation is the resonance frequency of a straight half-wave dipole with a length of , and by setting in Equation (8) and in Equation (9), the equations fit approximately on the data points with an of and respectively. The precision of the fitting is illustrated in Figure A2a,b in Appendix A.
(8) |
(9) |
The surface fitting is made with the data in the domain of , and the range of and . Similarly, these equations can also be solved for considering a or of choice. By combining Equations (8) and (9), we reach the following Equation (10), which defines solely based on and does not depend on , as shown in Figure A2c in Appendix A.
(10) |
where:
(11) |
4.2.3. The Design Steps Using Method 2
Choosing a wire length and
Calculating for different values, or calculate for a given
Calculating for the chosen in step 2
Readjusting (and subsequently updating ) while keeping fixed to reach the desired resonance frequency
Verify the design by simulating the antenna model based on Equation (1)
Finish if the desired frequency is acquired; otherwise, repeat from Step 4.
4.2.4. Advantages of Method 2 Based on
This design method has three advantages compared to the previous method, based on . First, the design is made directly based on and values and no integrals need to be solved to calculate for each iteration of the design process. Second, the estimation of has a better separation for adjacent values compared to the previous method. Third, if the designer finishes the design process and then decides to go with another factor, they will not need to start over. By only repeating the second step, a new can be calculated for the previously chosen resistance, and then can be readjusted. As shown in Equation (10), the resonance frequency of the antenna will not change as long as the designer keeps the previously chosen radiation resistance for the design.
4.3. Tuning Considerations
The factors affecting classic straight dipole antenna characteristics also apply to the sinusoidal dipoles, such as feeding point gap width, wire conductivity, and wire thickness [32]. All simulations were achieved using PEC as the material of the antenna wires. For convenience, the designer might consider extending the feeding point gap of to a larger value for high-frequency antennas where is shorter than a kilometer. In this case, the (or ) factor needs to be adjusted to a slightly lower value for compensating the inductive effect caused by the extra gap widening.
All the data presented from the simulation runs in this work were prepared with the assumption of a very thin wire with a diameter of less than . For an antenna made of a thicker wire, the (or ) parameter needs to be adjusted to a slightly higher value to achieve the desired radiation resistance on resonance.
5. Fabrication and Measurement
5.1. Fabrication Process
Two sample high-frequency antennas with are fabricated as a proof-of-concept. Table 2 shows the geometrical parameters used for the fabrication of both antennas. The antenna is designed and simulated for 800 MHz and impedance. A copper-made antenna is fabricated as the reference, and a second antenna is also made using a conductive flexible polymer suitable for wearable sensor applications.
Table 2.
Parameter | Wire Thickness | |||
---|---|---|---|---|
Value | 74.54 mm | 5.65 mm | 5 | 1.4 mm |
Compared to the previously introduced traditional antenna sensor based on silica hollow-core fibers, the newly developed polymer fiber is enduring, flexible, and sustains its electrical characteristics better than silica hollow-core fibers [37]. The conductive polymer is biocompatible, highly flexible, and resistant to water and other perturbations. It can be easily sewn on textiles and bending, twisting, or stretching does not break it. The measured resistance of the material is around and is observed to have a good performance in high frequency.
The composition of the conductive polymer fiber is a combination of poly (ethylene-co-vinyl acetate) (PEVA) polymer (Sigma-Aldrich, St. Louis, MO, USA) and multi-walled carbon nanotubes (MWCNTs) (commercially available at Cheaptubes, Grafton, VT, USA, with a carbon purity of 95 wt%) with a composition of 41 wt% mass of MWCNT and 59 wt% mass of PEVA and without any purifications.
The fabrication steps of the conductive polymer are shown in Figure 8a. For an hour, the MWCNT nanoparticles are sonicated in 10 mL of tetrahydrofuran (THF) (Fisher Scientific International, Waltham, MA, USA). Afterward, the PEVA polymer and the MWCNTs solution are mixed by mechanical stirring for one hour at 1400 rpm. The mixture is then sonicated for an additional 180 min for better dispersion. Finally, the colloidal solution is placed in the oven at 100 °C for 15 min to obtain a high-viscosity composite.
The composite of the conductive fiber is extruded [38] using a commercially available syringe, as shown in Figure 8b, and is left to dry out. The initial thickness of conductive fiber is 1.6 mm, which reduces to 1.4 mm after the drying process. The scanning electron microscopy (SEM) image of the cross-section of the polymer wire is presented in Figure 8c.
5.2. Measurements
The fabricated antennas are shown in Figure 9a,b and are fed using the commercially available 1:1 balun TC1-1-13MA+ from Mini-Circuits [39]. The measurements are made using a calibrated VNA system, with effects of the transmission line de-embedded from the final scattering parameters (S-Parameters) readout [40]. Table 3 shows the measured specifications of the fabricated antennas. The return loss of the antennas is also presented in Figure 9c. Each measurement is repeated eight times, and the average values are reported. The measurements show a good agreement between the antennas and the simulation. The differences are due to the error in fabrication, the material specifications, and non-rigid nature of the polymer wire.
Table 3.
Antenna | Operation Frequency | Impedance on Frequency |
---|---|---|
Copper | 790 MHz | |
Conductive Polymer (Free space) |
827 MHz | |
Conductive Polymer (Over the Body) |
808 MHz |
It can be seen that the resonance frequency of the polymer antenna is changed when it is placed over the body. There are two factors contributing to this frequency shift. The first one is the changes in the antenna’s surrounding material in its reactive near-field region, which makes a change in the impedance of the antenna seen from the feeding circuit, resulting in an impedance mismatch and therefore affecting the resonance frequency and the radiation resistance of the antenna [41].
The other factor causing this shift is the deviation of the antenna’s dimensions due to its initial stretching when the patient wears the smart textile, as shown in Figure 10. Therefore, it is recommended that the T-shirt selected for the antenna integration be a right fit for the patient’s body form and not too tight. Otherwise, the initial state of the antenna sensor will be considerably stretched, which would potentially limit the dynamic range of the antenna sensor.
5.3. The Durability of the Antenna Sensor
An experiment is performed in order to demonstrate the durability of the conductive polymer material for wearable smart textile applications intended for everyday use. A antenna sensor is fabricated and sewn on a piece of fabric, and its electrical specifications are measured. The fabric and the antenna sensor are washed for 20 cycles, and the measurements are performed again after each cycle.
During each step, the fabric is submerged in a container filled with tap water and detergent and is stirred vigorously to simulate a washing procedure. The fabric is taken out after 5 min, and then it is rinsed using tap water. Next, a piece of a napkin is used to remove the excessive wetness of the fabric. Finally, a heat gun is used for 10 to 15 min to completely dry out the fabric and antenna sensor. The specifications of the antenna sensor are remeasured and recorded after the complete dry out.
The container water and the detergent were refreshed every five cycles. The SMA connectors were held outside the water during the washing process, as shown in Figure 11. The heat gun is placed at least 15 cm away from the fabric during the drying process to prevent accidental burning due to its high temperature and is manually swung over the fabric to ensure complete dryness.
The measurements after each cycle are shown in Figure 12. It can be seen that there is a slight shift in the antenna’s operation frequency throughout the cycles, which could be due to the antenna deformations or fabric shrinkage caused by the heat during the drying process. The reflection loss of the antenna is still ideally below , and despite the slight frequency shift, the antenna’s performance is not significantly affected after 20 wash cycles.
6. Discussion
6.1. Strain Sensitivity
The introduced antenna design is notably valuable in strain sensing applications. It was previously shown in Figure 3 that the impedance and the resonance frequency of the antenna shift as changes when the sinusoidal dipole becomes stretched or compressed along its axis. One can exploit this behavior and make a sinusoidal antenna out of flexible conductors and record the S-parameters of the antenna over time as an indicator of the strain applied to the antenna [4]. The strain detection can be achieved by tracking the resonance frequency or measuring the reflection coefficient on a fixed frequency.
The traditional antenna sensor employed in previous works on respiration monitoring [2,3,4] is essentially a sinusoidal half-wave dipole . Higher values can increase the sensitivity of the antenna sensor. For comparison, by choosing , the resonance frequency sensitivity of the antenna versus will be times more than the sensitivity demonstrated by the traditional antenna. It increases to and times more for the antennas and , respectively, which is a significant improvement. Figure 13 shows the trend of sensitivity improvement for different values.
Although a higher value can provide better sensitivity, the advantage is reduced as become larger and larger. For instance, raising from 7 to 9 only improves the sensitivity by 12%, while changing from 2 to 4 will boost the sensitivity by a significant amount of 83%. Moreover, an antenna sensor designed with a very high value could be challenging to fabricate if the wire is relatively thick, and it will not be easy to integrate the antenna into wearable applications.
Table 4 summarizes the characteristics of this work compared to other recently published works on flexible antennas for strain sensing. Stretching strain is defined as where is the initial antenna sensor length, and stretchability is which is the maximum amount of the possible strain that can be applied to the sensor, expressed in percentage [7]. Bending strain is defined as where is the antenna sensor thickness and is the bending radius. The maximum bending is defined as the angle at which the sensor cannot be bent any further [11]. Exceeding the limits of the reported stretchability (or maximum bending) is either destructive for the antenna sensor or yields unreliable sensor readings [7,11]. The sensitivity to strain is also defined as which is the normalized frequency shift for an applied strain of [7,11]. Table 5 compares recent works on another category of antenna strain sensors primarily used in structural health monitoring to detect surface strains and cracks in the structures.
Table 4.
Description | Strain Type | Stretchability/Max. Bending | Sensitivity to Strain |
Year | Ref. |
---|---|---|---|---|---|
Sinusoidal dipole antenna * | Stretching | 30% | 0.40 | 2022 | This work |
Serpentine meshed patch over ground plane | Stretching | 40% | 0.20 | 2021 | [7] |
Serpentine meshed in patch and ground planes | Stretching | 100% | 0.25 | 2021 | [7] |
RFID Meandered half-wave dipole in Ecoflex | Stretching | Not provided | 0.141 ** | 2019 | Based on [8] |
Flexible planar dipole antenna over Kepton tape | Stretching | Not provided | 0.066 ** | 2012 | Based on [42] |
Liquid metal loop antenna | Stretching | 40% | 0.18 | 2009 | [43] |
Graphene patch antenna over copper tape | Bending | Not provided | 1.4 | 2021 | [9] |
Flexible multi-layer graphene film | Bending | Not provided | 5.39 | 2018 | [10] |
Aluminum tape patch over cellulose substrate | Bending | 3.49 | 2016 | [11] |
* With the assumption of and the initial . In the case of using adequately thin wires, a higher initial and therefore higher stretchability could be achieved. ** The original author does not provide the sensitivity directly. The presented value is calculated from the reported data.
Table 5.
Description | Resonance Freq | Sensitivity to Strain (kHz/με) * |
Year | Ref. |
---|---|---|---|---|
Double split-ring resonator (dSRR) antenna | 2.725 GHz | −1.548 | 2022 | [16] |
Rectangular microstrip antenna | 2.725 GHz | −2.379 | 2022 | [16] |
Rectangular microstrip antenna | 2.469 GHz | −2.847 | 2021 | [12] |
Sierpinski fractal microstrip patch | 2.725 GHz | −1.18 | 2019 | [15] |
Circular patch antenna | 2.5 GHz | −2.05 | 2018 | [13] |
RFID folded patch antenna | 911.6 MHz | −0.76 | 2015 | [14] |
* The sensitivity of this category of antenna sensors is usually reported in absolute frequency.
A crucial factor for antenna sensor comparison is the magnitude of force needed to achieve a specific strain. This factor becomes especially important in applications with very small stretching forces. To the best of our knowledge, such a parameter is not reported in any of the works summarized in Table 4. However, the materials used in the fabrication of each antenna sensor are well described in the other works and this paper, which might indirectly address this issue. Nonetheless, a study on the magnitude of force required to achieve a specific strain on the antenna introduced here is undoubtedly an interesting point that could be experimentally measured and included in a forthcoming paper.
6.2. Effects of Bending and Twisting
Although the antenna sensor introduced here is ideally designed for applications where the deformations are mainly along the Z-axis, the effects of other forms of deformations are also investigated to understand the antenna’s behavior better. A sample sinusoidal antenna with the geometrical parameters introduced in Table 2 is simulated in twisted and bent conditions, as illustrated in Figure 14. The twisting is performed around the Z-axis up to , and the cylindrical bending is applied along the X-axis up to .
Figure 15 presents the antenna simulation results for different bend and twist angles. There is a significant change in the antenna’s resistance on the resonance frequency under bending deformation. It is shown that the more the antenna becomes bent, the lower becomes the resistance on the resonance frequency. Bending can also shift the resonance frequency to slightly higher, which is negligible in low bending angles and will be less than 2% for . In comparison, twisting does not significantly affect the resistance on resonance and shows a slightly decreasing trend. It also has a similar effect on the resonance frequency, making it drop by as much as 2.5% at of twisting according to the simulation.
6.3. Specific Absorption Rate (SAR) Analysis
The amount of radio frequency (RF) radiation exposure is a critical factor that should be controlled in the radiating systems embedded in home appliances and portable devices. This concern becomes even more important in wearable devices and smart textiles due to the continuity of radiation and the close proximity of the radiating elements to body tissues. The amount of RF exposure is regulated using a metric named specific absorption rate (SAR), which is the time derivative of an incremental amount of energy dissipated in a specific mass of tissues [44]. The Federal Communications Commission (FCC) defines the limit of the SAR level of mobile phones for public exposure to 1.6 W/Kg, averaged over 1 g of tissue [45].
An analysis of SAR level is made on a sinusoidal antenna with and designed for on its 800 MHz resonance frequency. The antenna model is simulated while placed over the chest of the human body phantom model named Hugo from the CST Voxel Family, with a voxel resolution of [31]. The gap between the antenna and the phantom model is considered 2 mm. The calculated SAR level for a reference excitation power of (equivalent to 0 dBm), averaged over 1 g of tissue, has a maximum value of 0.0138 W/Kg. Therefore, the maximum possible excitation power complying with FCC SAR level limitations can be calculated using a simple ratio as shown in Equation (12). Based on this calculation, the excitation power must be less than (equivalent to 20.64 dBm) to comply with the limitations. Figure 16 presents the body phantom model and the SAR simulation results.
(12) |
7. Conclusions
A new flexible dipole antenna with a sinusoidal geometry is introduced. The radiative and electrical specifications of the antenna and the effect of geometrical parameters are presented. The antenna is fabricated using a biocompatible conductive polymer with high flexibility and great endurance. In contrast to the previous generation of antenna sensors made from glass-based material, the new antenna will not break by twisting, bending, and stretching, and can be used in wearable applications without compromising the user’s comfort. It is also shown that the new antenna design can have up to 5.5 times more sensitivity than the traditional antenna sensor employed in the previous works for respiration monitoring [2].
Additionally, a design guide for sinusoidal antennas is provided, and curve fittings are performed to estimate the geometrical factors based on the radiation characteristics of choice. The equations presented here provide a starting point for fine-tuning the geometrical parameters to achieve the desired radiation characteristics. Finally, a sample antenna is designed and fabricated in two versions, one with copper and one with the conductive polymer. The fabrication method is described, and the electrical specifications of the fabricated antennas are reported in free space and over the body. It is shown that there is a good agreement between the simulation and the measurements. Experiments are performed to prove the durability of the antenna sensor for everyday use, and it is shown that the performance of the antenna does not decay after 20 washing, rinsing, and drying cycles.
The contributions of this paper were mainly in the antenna design, characteristics, and strain sensitivity analysis. It was shown that the new antenna could provide better performance in sensing and be a superior choice for wearable applications compared to its previous generation due to its miniature size, flexibility, and durability. An upcoming paper will be focused on the application of the introduced antenna in a vital signal monitoring system. The antenna’s performance in sensing applications will be evaluated, and the measurement data will be provided.
Appendix A
The correlation between the simulated data and the introduced fitted equations is illustrated in this appendix for both design methods based on and .
Author Contributions
Conceptualization, M.A. and M.R.; Data curation, M.A.; Formal analysis, M.A.; Funding acquisition, Y.M.; Investigation, M.A. and M.R.; Methodology, M.A. and M.R.; Project administration, M.-A.D., A.M. and Y.M.; Resources, M.-A.D., A.M. and Y.M.; Software, M.A.; Supervision, M.-A.D., A.M. and Y.M.; Visualization, M.A.; Writing—original draft, M.A.; Writing—review & editing, M.A., M.R., A.M. and Y.M. All authors have read and agreed to the published version of the manuscript.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Conflicts of Interest
The authors declare no conflict of interest.
Funding Statement
This research was supported by the Sentinel North program of Université Laval, made possible, in part, thanks to funding from the Canada First Research Excellence Fund.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Kraus J.D. Antennas. 2nd ed. McGraw-Hill; New York, NY, USA: 1988. (McGraw-Hill Series in Electrical Engineering). [Google Scholar]
- 2.Roudjane M., Bellemare-Rousseau S., Khalil M., Gorgutsa S., Miled A., Messaddeq Y. A Portable Wireless Communication Platform Based on a Multi-Material Fiber Sensor for Real-Time Breath Detection. Sensors. 2018;18:973. doi: 10.3390/s18040973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Roudjane M., Bellemare-Rousseau S., Drouin E., Belanger-Huot B., Dugas M.-A., Miled A., Messaddeq Y. Smart T-Shirt Based on Wireless Communication Spiral Fiber Sensor Array for Real-Time Breath Monitoring: Validation of the Technology. IEEE Sens. J. 2020;20:10841–10850. doi: 10.1109/JSEN.2020.2993286. [DOI] [Google Scholar]
- 4.Guay P., Gorgutsa S., LaRochelle S., Messaddeq Y. Wearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile. Sensors. 2017;17:1050. doi: 10.3390/s17051050. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Mulholland K., Virkki J., Raumonen P., Merilampi S. Wearable RFID Perspiration Sensor Tags for Well-Being Applications—From Laboratory to Field Use. In: Eskola H., Väisänen O., Viik J., Hyttinen J., editors. EMBEC & NBC 2017. Volume 65. Springer; Singapore: 2018. pp. 1012–1015. IFMBE Proceedings. [Google Scholar]
- 6.Panunzio N., Bianco G.M., Occhiuzzi C., Marrocco G. RFID Sensors for the Monitoring of Body Temperature and Respiratory Function: A Pandemic Prospect; Proceedings of the 2021 6th International Conference on Smart and Sustainable Technologies (SpliTech); Bol and Split, Croatia. 8–11 September 2021; pp. 1–5. [Google Scholar]
- 7.Nikbakhtnasrabadi F., El Matbouly H., Ntagios M., Dahiya R. Textile-Based Stretchable Microstrip Antenna with Intrinsic Strain Sensing. ACS Appl. Electron. Mater. 2021;3:2233–2246. doi: 10.1021/acsaelm.1c00179. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Teng L., Pan K., Nemitz M.P., Song R., Hu Z., Stokes A.A. Soft Radio-Frequency Identification Sensors: Wireless Long-Range Strain Sensors Using Radio-Frequency Identification. Soft Robot. 2019;6:82–94. doi: 10.1089/soro.2018.0026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Sindhu B., Kothuru A., Sahatiya P., Goel S., Nandi S. Laser-Induced Graphene Printed Wearable Flexible Antenna-Based Strain Sensor for Wireless Human Motion Monitoring. IEEE Trans. Electron Devices. 2021;68:3189–3194. doi: 10.1109/TED.2021.3067304. [DOI] [Google Scholar]
- 10.Tang D., Wang Q., Wang Z., Liu Q., Zhang B., He D., Wu Z., Mu S. Highly Sensitive Wearable Sensor Based on a Flexible Multi-Layer Graphene Film Antenna. Sci. Bull. 2018;63:574–579. doi: 10.1016/j.scib.2018.03.014. [DOI] [PubMed] [Google Scholar]
- 11.Kanaparthi S., Sekhar V.R., Badhulika S. Flexible, Eco-Friendly and Highly Sensitive Paper Antenna Based Electromechanical Sensor for Wireless Human Motion Detection and Structural Health Monitoring. Extreme Mech. Lett. 2016;9:324–330. doi: 10.1016/j.eml.2016.09.007. [DOI] [Google Scholar]
- 12.Ossa-Molina O., Duque-Giraldo J., Reyes-Vera E. Strain Sensor Based on Rectangular Microstrip Antenna: Numerical Methodologies and Experimental Validation. IEEE Sens. J. 2021;21:22908–22917. doi: 10.1109/JSEN.2021.3107136. [DOI] [Google Scholar]
- 13.Lopato P., Herbko M. A Circular Microstrip Antenna Sensor for Direction Sensitive Strain Evaluation. Sensors. 2018;18:310. doi: 10.3390/s18010310. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Yi X., Wu T., Wang Y., Tentzeris M.M. Sensitivity Modeling of an RFID-Based Strain-Sensing Antenna With Dielectric Constant Change. IEEE Sens. J. 2015;15:6147–6155. doi: 10.1109/JSEN.2015.2453947. [DOI] [Google Scholar]
- 15.Herbko M., Lopato P. Microstrip Patch Strain Sensor Miniaturization Using Sierpinski Curve Fractal Geometry. Sensors. 2019;19:3989. doi: 10.3390/s19183989. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Herbko M., Lopato P. Application of a Single Cell Electric-SRR Metamaterial for Strain Evaluation. Materials. 2021;15:291. doi: 10.3390/ma15010291. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Gouveia C., Loss C., Pinho P., Vieira J. Different Antenna Designs for Non-Contact Vital Signs Measurement: A Review. Electronics. 2019;8:1294. doi: 10.3390/electronics8111294. [DOI] [Google Scholar]
- 18.De Fazio R., Stabile M., De Vittorio M., Velázquez R., Visconti P. An Overview of Wearable Piezoresistive and Inertial Sensors for Respiration Rate Monitoring. Electronics. 2021;10:2178. doi: 10.3390/electronics10172178. [DOI] [Google Scholar]
- 19.Wagih M., Malik O., Weddell A.S., Beeby S. E-Textile Breathing Sensor Using Fully Textile Wearable Antennas. Eng. Proc. 2022;15:9. doi: 10.3390/engproc2022015009. [DOI] [Google Scholar]
- 20.El Gharbi M., Fernández-García R., Gil I. Embroidered Wearable Antenna-Based Sensor for Real-Time Breath Monitoring. Measurement. 2022;195:111080. doi: 10.1016/j.measurement.2022.111080. [DOI] [Google Scholar]
- 21.Nakano H., Tagami H., Yoshizawa A., Yamauchi J. Shortening Ratios of Modified Dipole Antennas. IEEE Trans. Antennas Propag. 1984;32:385–386. doi: 10.1109/TAP.1984.1143321. [DOI] [Google Scholar]
- 22.Rashed J., Tai C.-T. A New Class of Resonant Antennas. IEEE Trans. Antennas Propag. 1991;39:1428–1430. doi: 10.1109/8.99054. [DOI] [Google Scholar]
- 23.Olaode O.O., Palmer W.D., Joines W.T. Effects of Meandering on Dipole Antenna Resonant Frequency. IEEE Antennas Wirel. Propag. Lett. 2012;11:122–125. doi: 10.1109/LAWP.2012.2184255. [DOI] [Google Scholar]
- 24.Endo T., Sunahara Y., Satoh S., Katagi T. Resonant Frequency and Radiation Efficiency of Meander Line Antennas. Electron. Commun. Jpn. Pt. II. 2000;83:52–58. doi: 10.1002/(SICI)1520-6432(200001)83:1<52::AID-ECJB7>3.0.CO;2-7. [DOI] [Google Scholar]
- 25.Ali M., Stuchly S.S. Short Sinusoidal Antennas for Wireless Communications; Proceedings of the IEEE Pacific Rim Conference on Communications, Computers, and Signal Processing; Victoria, BC, Canada. 17–19 May 1995; pp. 542–545. [Google Scholar]
- 26.Kakoyiannis C.G., Constantinou P. Radiation Properties and Ground-Dependent Response of Compact Printed Sinusoidal Antennas and Arrays. IET Microw. Antennas Propag. 2010;4:629–642. doi: 10.1049/iet-map.2009.0162. [DOI] [Google Scholar]
- 27.Chang L., He S., Zhang J.Q., Li D. A Compact Dielectric-Loaded Log-Periodic Dipole Array (LPDA) Antenna. IEEE Antennas Wirel. Propag. Lett. 2017;16:2759–2762. doi: 10.1109/LAWP.2017.2744983. [DOI] [Google Scholar]
- 28.Trinh-Van S., Kwon O.H., Jung E., Park J., Yu B., Kim K., Seo J., Hwang K.C. A Low-Profile High-Gain and Wideband Log-Periodic Meandered Dipole Array Antenna with a Cascaded Multi-Section Artificial Magnetic Conductor Structure. Sensors. 2019;19:4404. doi: 10.3390/s19204404. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Marrocco G. Gain-Optimized Self-Resonant Meander Line Antennas for RFID Applications. IEEE Antennas Wirel. Propag. Lett. 2003;2:302–305. doi: 10.1109/LAWP.2003.822198. [DOI] [Google Scholar]
- 30.Rao K.V.S., Nikitin P.V., Lam S.F. Antenna Design for UHF RFID Tags: A Review and a Practical Application. IEEE Trans. Antennas Propag. 2005;53:3870–3876. doi: 10.1109/TAP.2005.859919. [DOI] [Google Scholar]
- 31.CST Studio Suite 3D EM Simulation and Analysis Software. [(accessed on 3 May 2022)]. Available online: https://www.3ds.com/products-services/simulia/products/cst-studio-suite/
- 32.Furse C.M., Gandhi O.P., Lazzi G. Modern Antenna Handbook. John Wiley & Sons, Ltd.; Hoboken, NJ, USA: 2008. Wire Elements: Dipoles, Monopoles, and Loops; pp. 57–95. [Google Scholar]
- 33.Coleman T.F., Li Y. An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds. SIAM J. Optim. 1996;6:418–445. doi: 10.1137/0806023. [DOI] [Google Scholar]
- 34.Ritter A., Muñoz-Carpena R. Performance Evaluation of Hydrological Models: Statistical Significance for Reducing Subjectivity in Goodness-of-Fit Assessments. J. Hydrol. 2013;480:33–45. doi: 10.1016/j.jhydrol.2012.12.004. [DOI] [Google Scholar]
- 35.Carlson B.C. Numerical Computation of Real or Complex Elliptic Integrals. Numer. Algorithms. 1995;10:13–26. doi: 10.1007/BF02198293. [DOI] [Google Scholar]
- 36.MathWorks—Makers of MATLAB and Simulink. [(accessed on 30 April 2021)]. Available online: https://www.mathworks.com/
- 37.Gauthier N., Roudjane M., Frasie A., Loukili M., Saad A.B., Pagé I., Messaddeq Y., Bouyer L.J., Gosselin B. Multimodal Electrophysiological Signal Measurement Using a New Flexible and Conductive Polymer Fiber-Electrode; Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine Biology Society (EMBC); Montreal, QC, Canada. 20–24 July 2020; pp. 4373–4376. [DOI] [PubMed] [Google Scholar]
- 38.Buckley A., Long H.A. The Extrusion of Polymers below Their Melting Temperatures by the Application of High Pressures. Polym. Eng. Sci. 1969;9:115–120. doi: 10.1002/pen.760090207. [DOI] [Google Scholar]
- 39.TC1-1-13MA+ on Mini-Circuits. [(accessed on 5 August 2021)]. Available online: https://www.minicircuits.com/WebStore/dashboard.html?model=TC1-1-13MA%2B.
- 40.Dambrine G. Microwave De-Embedding. Elsevier Science; Amsterdam, The Netherlands: 2013. Millimeter-Wave Characterization of Silicon Devices under Small-Signal Regime: Instruments and Measurement Methodologies; pp. 47–96. [Google Scholar]
- 41.Nikolova N.K., Ravan M., Amineh R.K. Advances in Imaging and Electron Physics. Volume 174. Elsevier; Amsterdam, The Netherlands: 2012. Substrate-Integrated Antennas on Silicon; pp. 391–458. [Google Scholar]
- 42.Jang S.-D., Kim J. Passive Wireless Structural Health Monitoring Sensor Made with a Flexible Planar Dipole Antenna. Smart Mater. Struct. 2012;21:027001. doi: 10.1088/0964-1726/21/2/027001. [DOI] [Google Scholar]
- 43.Cheng S., Rydberg A., Hjort K., Wu Z. Liquid Metal Stretchable Unbalanced Loop Antenna. Appl. Phys. Lett. 2009;94:144103. doi: 10.1063/1.3114381. [DOI] [Google Scholar]
- 44.IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 KHz to 300 GHz. IEEE; Piscataway, NJ, USA: 1992. [DOI] [Google Scholar]
- 45.Specific Absorption Rate (SAR) for Cellular Telephones|Federal Communications Commission. [(accessed on 5 May 2022)]; Available online: https://www.fcc.gov/general/specific-absorption-rate-sar-cellular-telephones.