Abstract
Corneal injuries are a major cause of blindness worldwide. To restore corneal integrity and clarity, there is a need for regenerative bio-integrating materials for in-situ repair and replacement of corneal tissue. Here, we introduce Light-curable COrnea Matrix (LC-COMatrix), a tunable material derived from decellularized porcine cornea extracellular matrix containing un-denatured collagen and sulfated glycosaminoglycans. It is a functionalized hydrogel with proper swelling behavior, biodegradation, and viscosity that can be cross-linked in situ with visible light, providing significantly enhanced biomechanical strength, stability, and adhesiveness. Cross-linked LC-COMatrix strongly adheres to human corneas ex vivo and effectively closes full-thickness corneal perforations with tissue loss. Likewise, in vivo, LC-COMatrix seals large corneal perforations, replaces partial-corneal stromal defects and bio-integrates into the tissue in rabbit models. LC-COMatrix is a natural ready-to-apply bio-integrating adhesive that is representative of native corneal matrix with potential applications in corneal and ocular surgeries.
Keywords: Cornea, Bio-adhesive, Decellularized Tissue, Hydrogel, Light-Curing, Extracellular Matrix
1. Introduction
Corneal injuries and scarring are a major cause of blindness worldwide. Currently, the most effective therapy for corneal blindness is corneal transplantation using cadaver tissue which is only available to less than 5% of patients, worldwide. Donor organ shortage, expensive and skill-based surgical procedures, and graft-rejection are major challenges of corneal transplantation.[1] Fabrication of intact decellularized corneas from xenogeneic sources has been pursued for more than a decade to overcome the donor cornea shortage obstacle,[2] however; this strategy has not shown promising results in clinical translation.[3] A novel approach to meet the clinical demand for cornea tissue replacement and wound closure is to develop in-situ cross-linking biomaterials. Currently, none of the available tissue sealants in the market such as fibrin glue (e.g. VISTASEAL™, TISSEEL™), cyanoacrylate based bio-glues (e.g. Histoacryl®, DERMABOND®), and PEG-based bio-glues (ReSure®, OcuSeal®) are suitable as a pro-regenerative corneal stromal replacement, and could be applied only for temporary sealing of ocular penetrations[4]. Fibrin gels are limited by the lack of necessary biomechanical stability and time-consuming preparations,[5] cyanoacrylate is opaque and provides no opportunity for biointegration,[6] and the PEG-based products lack the stability and strength for application in larger corneal defects.[4]
Recently, several experimental products have been introduced for the in-situ repair and/or replacement of the corneal stroma. These products are generally classified into two categories. The first category is in-situ light-curable products that need to be cured with a light-source to initiate cross-linking such as gelatin-methacrylate (GelMA),[7] and thiol–acrylate gelatin.[8] The main advantages of light-curable products over chemically cross-linkable products are lack of pre-application preparation, and more control over the photo-cross-linking process. However, gelatin-based products are commonly denatured purified skin collagen which is not representative of corneal tissue and has temperature dependent viscosity which limits their user-friendly application in clinical settings. The second group are in-situ chemically cross-linkable products (e.g., fibrin-based and PEG-based materials).[9] These materials are commonly prepared by combining of two or three components and the cross-linking starts immediately. Limited control on cross-linking reaction and lack of proper biomechanical stability are the constraints of this category.
A novel approach for the in-situ repair and regeneration of the cornea is to engineer biomaterials from decellularized corneal ECM containing a balanced composition of collagens, glycoproteins and sulfated glycosaminoglycans (sGAGs) analogous to the native cornea.[10] Recent studies on biomaterials fabricated from other decellularized tissues have shown that they can not only be applied as tissue engineering scaffolds, but they also have regenerative effects compared to purified and denatured natural biomaterials.[10b, 11] Moreover, it has been shown that porcine corneal matrix protein has the highest similarity to human corneal matrix protein across species.[12] Our group recently reported on a thermoresponsive hydrogel from decellularized porcine ECM, COMatrix (Cornea Matrix),[13] which is liquid at temperatures below 15°C and irreversibly forms a gel at 37°C. The fabricated thermoresponsive COMatrix is composed of various types of collagens as well as sulfated glycosaminoglycans and proteoglycans with wound healing effects including lumican, keratocan and laminin.[13a] The exact mechanism of thermoresponsive behavior of the COMatrix hydrogel is not clear. However, it has been suggested that partially digested collagens are thermodynamically able to re-build the structure at 37°C.[14] Moreover, the presence of sGAGs in the fabricated biomaterial increase the complexity of thermo-gelation.[13–14] We have investigated the use of thermoresponsive COMatrix as an ocular surface bandage for enhancing the healing of corneal epithelial wounds.[13b] However, the thermoresponsive COMatrix, as well as all similar decellularized cornea-based hydrogels reported by others,[10a, 10c, 15] lack the biomechanical properties and stability needed for the repair and/or replacement of corneal stromal defects. Many protocols for chemical crosslinking of decellularized ECM-based hydrogels lead to the loss of transparency (e.g., following genipin cross-linking) or induce high-levels of cytotoxicity.[16] Moreover, chemical cross-linking requires pre-application combination of biomaterial and cross-linker with limited control over the cross-linking process. Therefore, we set out to develop and optimize a protocol to functionalize our thermoresponsive COMatrix hydrogel to a Light Curable Cornea Matrix (LC-COMatrix), which after light curing achieves a biomechanical strength comparable to human cornea while maintaining its optical and biological effects (Figure 1). Here, we have compositionally and mechanically characterized LC-COMatrix and evaluated its adhesion strength compared to fibrin glue and GelMA ex vivo. Moreover, the biocompatibility and potential application of LC-COMatrix for the in-vivo repair and replacement of full-thickness corneal stromal defects was evaluated in a rabbit model.
2. Results
2.1. Compositional and Physical Characterization of Light-Curable COMatrix Hydrogel
The previously reported thermoresponsive COMatrix hydrogels have the advantage of genuine resemblance to corneal tissue compared to other biomaterials like gelatin or fibrin;[13a] however, they are limited by the biomechanical characteristics (storage modulus (G’), 83.3±4.2 Pa)[13a] which makes it unsuitable for corneal stromal repair or replacement without additional cross-linking. Thus, in pilot studies we evaluated multiple approaches, including photo and chemical based cross-linking methods, in order to achieve the necessary biomechanical properties without compromising transparency or leading to undue toxicity. Considering user-friendly preparation and application, potential for shelf storage, controllable cross-linking process, low toxicity, and preserved transparency of the final product, we found that among the various methods for functionalizing the thermoresponsive COMatrix, reacting with methacrylate anhydride (MA) was able to fabricate a Light-Curable Cornea Matrix (LC-COMatrix) hydrogel without loss of transparency (Figure 1). Visible light curing (preferred over UV based photo curing systems) was enabled by combining LC-COMatrix with an FDA approved photo-initiating cocktail including eosin Y, triethanolamine (TEOA) and N-vinylcaprolactam (VC). Curing the prepared combination with green-light (520 nm, peak absorbance for eosin Y), begins the cross-linking reaction and stiffens the hydrogel.[7] LC-COMatrix hydrogel samples were prepared as ready-to-cure and loaded in syringes (Supplementary Figure S1) for further experiments.
To optimize the functionalization protocol, COMatrix was reacted with methacrylate anhydride (MA) with different ratios including 2:1 (0.5x), 1:1 (1x), and 1:2 (2x). The degree of functionalization was measured with Nuclear Magnetic Resonance (NMR) spectroscopy and fluoraldehyde assay. NMR spectroscopy showed the peaks for methacryloyl (methacrylate/methacrylamide) functional groups at 5.5 to 6 ppm compared to non-functionalized COMatrix (Figure 2A). As the ratio of MA to COMatrix increased, the methacrylate peaks became stronger indicating more attached methacrylate groups to the fabricated matrix. This was consistent with results from the fluoraldehyde assay which measured the degree of functionalization (DoF) by quantifying the total number of free amine-groups (majority of methacrylate groups are attaching to free amine groups). With increasing ratio of MA:COMatrix from 1:2 to 1:1, and to 2:1, the number of free amine groups decreased while the DoF increased. The DoF was 12.7±2.5%, for 0.5x, 40±4.5% for 1x, and 70.3±5.2% for 2x LC-COMatrix (P<0.0001, ANOVA, N=4, Figure 2B).
To evaluate whether the functionalization process influenced the general content of the COMatrix, the collagen and sulfated glycosaminoglycan compositions in COMatrix and variants of LC-COMatrix were measured and compared with human cadaver corneas and GelMA. Similar collagen and sGAG concentrations were found in all samples indicating that the MA functionalization had not significantly affected the general content of COMatrix and was comparable to human corneas. On the other hand, only collagen was detected in GelMA (Figure 2C and 2D).
Swelling of cornea is one of the major reasons for its decreased optical clarity (and visual acuity) after corneal repair or transplantation. Therefore, any potential biomaterial for corneal stromal repair needs to have negligible swelling while it is in an aqueous environment. Here, the water content of the cross-linked LC-COMatrix was measured while incubating in salt-balanced solution and compared with those of cross-linked fibrin glue, 20% GelMA and cadaveric human cornea. The water content of COMatrix, GelMA and fibrin gel was more than 95% compared to 85.7±1.5% for human corneas. As presented in Figure 2E, human corneal buttons experienced a primary swelling of 3.3±0.9% while the 2x LC-COMatrix had less than one percent change in water content for the first day. The changes in the water contents of COMatrices, 20% GelMA and human corneas were negligible during the 18 days of follow-up indicating no significant swelling or degradation. Interestingly, the fibrin gel lost water weight during the experiment indicating progressive degradation.
To simulate and evaluate the in vivo biodegradability of fabricated corneal matrix hydrogels compared to human corneas, the constructs/tissues were exposed to collagenase and intermittently weighed. Human corneas incubated in collagenase experienced an initial increase in weight due to swelling after which during the 10-day exposure to collagenase the weight decreased by 68.8±5.3%. The degradation of LC-COMatrix samples was correlated with their DoF, with the 0.5x LC-COMatrix and 1x LC-COMatrix being 100% degraded after 10 days while the 2x LC-COMatrix was reduced by 90.4±1.7% in weight at 10 days. The COMatrix (non-light-curable form), 20% GelMA and fibrin glue were also found to be 100% degraded after 10 days but as shown in Figure 2F, their degradation rates were faster than LC-COMatrix.
2.2. Viscosity Characterization and Photo-Gelation Kinetics of Light-Curable COMatrix
One of the challenges with the application of current bio-adhesives in ophthalmology is the consistency of the bio-adhesive at the time of application.[6] Specifically, the bio-adhesive besides having strong adhesion after polymerization, requires robust cohesion before cross-linking. If the bio-adhesive has a low cohesion (very liquid) it will easily spread over the field to undesired areas before cross-linking, while if it is too viscous (very high cohesion), it will not adequately spread to provide coverage of the targeted area. For example, one of the main complaints of ophthalmologists who are using fibrin glue or cyanoacrylate on the corneal surface is the low cohesion of these products that leads to spreading on the surface to the unwanted areas after application and before cross-linking. GelMA also has the same drawback, since at or below room temperatures it has strong cohesion but after warming to 37° C the cohesion decreases significantly resulting in dispersal to surrounding areas.[17] One of the most common materials utilized in ophthalmology is a combination of sodium hyaluronate and chondroitin sulfate, so called “Ophthalmic ViscoElastic Agent (ViscoElastic)” which has proper cohesion that provides necessary augmentation and protection in ophthalmic surgeries. The shear-thinning characteristics of OVA make it a suitable injectable material for in-situ application. For the rheological characterizations of LC-COMatrix, we first measured the viscosity of 2x LC-COMatrix at 37, 25, and 12° C by increasing the shear rate from 0.01 to 1000 (S−1) and compared the results with a ViscoElastic, 20% GelMA and the thicker component (fibrinogen) of fibrin glue (prior to combining with thrombin the thinner component) (Figure 3A, 3B and 3C). The viscosity of 2x LC-COMatrix was considerably higher than fibrin glue and 20% GelMA at 37°C which had minimal dependence on the temperature, thus, it would not be expected to spread excessively to undesired areas after application. Moreover, the 2x LC-COMatrix showed shear-thinning like the ViscoElastic Agent, which indicates its potential for injections or 3D-printing. On the other hand, 20% GelMA showed shear-thickening followed by shear-thinning by increasing in the shear rate at 25°C and 12°C (Figure 3A and 3B). The temperature dependent viscosity and shear-thickening behavior of GelMA at room temperature and lower temperatures has also been shown in previous studies,[17–18] which is not desirable for injection in clinical settings. This was the main reason that GelMA was combined with hyaluronic acid or chitosan to tailor its viscosity,[19] while the LC-COMatrix does not need supplemental materials since it is a natural combination of collagen and sGAGs.[13a]
A descriptive experiment was performed to evaluate the behavior of LC-COMatrix compared to cyanoacrylate, fibrin glue, ViscoElastic and 20% GelMA (37°C) while applied to an ex vivo human cornea in an upright position. This experiment simulated the same position of the patient’s eye in the ophthalmology clinic, where usually the bio-adhesives are applied at a slit-lamp biomicroscope. As presented in Figure 3D, cyanoacrylate spread downward due to gravity in about 6 seconds. Fibrin glue and 20% GelMA were displaced downward in 60 seconds; while the ViscoElastic and LC-COMatrix remained stable in the applied area for 5 minutes, which provides sufficient time for light-curing. The videos of this experiment are available as Supplementary Video S1 to S5. Furthermore, a quantitative image analysis was performed to measure the area covered by each bio-adhesive immediately after application and at 5 minutes follow-up and the change in covered area (%) was calculated (N= 4, Figure 3E). The changes in covered area by ophthalmic viscoelastic, fibrin glue, 20% GelMA, and cyanoacrylate after 5 minutes was 85.7±11.3%, 120.4±15.8%, 112.5±9.7%, and 405.2±27.3%, respectively. While the 2x LC-COMatrix covered area change was 5.1±2.4% (P<0.001 for LC-COMatrix compared to other bio-adhesives, N=3). Moreover, we evaluated whether the LC-COMatrix could be cured using the in-built green-light source of a slit-lamp biomicroscope (Supplementary Video S6). After 4 minutes of curing, the LC-COMatrix was strongly attached to a cadaveric human cornea mounted behind the slit-lamp (Supplementary Video S7).
To record the photo-gelation kinetics of LC-COMatrix and 20% GelMA by rheometry, the LC-COMatrices (0.5x, 1x, and 2x) were loaded onto the quartz glass surface of the rheometer with a green light source (100 μW/cm2) installed below. The junction gap was set to be 0.4 mm and the shear moduli (storage, G’, Figure 4E; and loss, G”, Figure 4F) were recorded at 0.159 Hz frequency and 5% strain for 1 minute. Then, the green light was turned on (Supplementary Figure S2) for 4 minutes while the recording continued. As plotted in Figs. 3E and 3F, LC-COMatrix undergoes rapid photo-gelation during the first minute of curing with green light which then becomes more flattened and plateaued depending on the DoF. For 0.5x LC-COMatrix, the cross-linking finished after almost 1 minute and the storage modulus did not increase. In case of 1x LC-COMatrix and 2x LC-COMatrix, more cross-linking occurred after the first minute surge evident by the increasing G’, but the slope of cross-linking was in accordance with the DoF. To measure the shear moduli of the fibrin glue, the two components were mixed and immediately loaded onto the rheometry plate and allowed to fully react for 30 minutes followed by recording at the same frequency and strain as above. The average G’ and G” for photo-gelated 2x LC-COMatrix was 7.8±0.5 kPa and 0.2±0.04 kPa, respectively, which was higher than fibrin glue with G’ of 4.8±0.3 kPa and G” of 0.5±0.07 kPa and 20% GelMA with G’ of 5.1±3.2 kPa and G” of 0.2±0.16 kPa (N=3, Figure 3E and 3F). The 1x LC-COMatrix and 0.5x LC-COMatrix had average G’ of 2.7±0.5 kPa and 0.4±0.04 kPa, and average G” of 0.2±0.03 kPa and 0.03±0.007 kPa, respectively. Supplementary Figure S2 presents a 2x LC-COMatrix sample after performing all the rheological tests while still preserving an intact structure.
2.3. Adhesion Strength of Light-Curable COMatrix on ex vivo Human Corneal Substrates
To measure the adhesion strength of LC-COMatrix, we conducted tensile adhesion tests using human corneas as the substrate. Human corneas were cut in half then fixed in the tensile testing grips with a 1 mm distance between the two halves (Illustrated in Figure 4A and representative photos in Supplementary Figure S3). The half-corneas were glued with LC-COMatrix with various DoFs, 20% GelMA (followed by 4 minutes green light-curing), cyanoacrylate, or fibrin glue (3 mm width, N=6 per group) and then subjected to tensile testing. The adhesion strength of 2x LC-COMatrix was 21.8±2.3 kPa which was significantly higher than that of 20% GelMA (11.1±3.8 kPa, p<0.0001), cyanoacrylate (10.7±2.3 kPa), and fibrin glue (4.9±2.3 kPa, p<0.0001). The adhesion strength of 1x LC-COMatrix and 0.5x LC-COMatrix were 11.1±3.7 kPa and 3.6±1.8 kPa, respectively (Figure 4B). In previous studies the adhesion strength of 20% GelMA after 4 minutes of light-curing was reported as 90.4±10.2 kPa using a setup with porcine skin. Here, for the first time we have established a setup using cadaveric human corneas to measure the adhesion strength of the developed biomaterial which could justify the observed difference.[7] The adhesion strength tunability of LC-COMatrix provides the potential to fabricate the bio-adhesive based on the targeted application.
2.4. Repair of ex-vivo Penetrating Human Corneal Wounds with Light-Curable COMatrix
To test the wound integrity following the repair of corneal injuries, we mounted human cadaver corneas in an artificial anterior chamber and measured the burst pressure (BP) of the wounds after sealing with different LC-COMatrices, 20% GelMA, fibrin glue, or cyanoacrylate (Figure 4C). The created injuries were 2 mm and 1 mm full thickness punch wounds (the cut tissue was removed), and 2.75 mm and 5.90 mm full thickness stab wounds created by surgical knives. After drying the injury sites, LC-COMatrix with various DoFs or 20% GelMA were applied to the injury site (Figure 4D and Supplementary Video S8) and cured with green light for 4 minutes (Figure 4E). Figure 4F to 4I present the photos of injuries before and after repair with 2x LC-COMatrix as well as the BP results for LC-COMatrices with various DoFs compared to 20% GelMA and fibrin glue (N=4 per group). The average BP of the 2 mm punch injury repaired with 2x LC-COMatrix was 327±175 mmHg (see Supplementary Video S9), while this value for 20% GelMA was 151±48 mmHg (p=0.007), for cyanoacrylate was 234±145 (p=0.27) and for fibrin glue was 11±4 mmHg (p<0.0001, Figure 4F). The LC-COMatrices with lower DoFs had lower burst pressures (1x LC-COMatrix BP, 240±113 mmHg, and 0.5x LC-COMatrix BP, 151±71 mmHg). The same pattern of results was seen with other types of penetrating corneal injuries, where the BPs for 1 mm punch, 2.75 mm cut, and 5.9 cut repaired with 2x LC-COMatrix were 300±160 mmHg, 542±86 mmHg, and 188±63 mmHg, respectively, compared to fibrin glue, which the BPs were 13±2 mmHg, 19±4 mmHg, and 8±4 mmHg, respectively (p<0.001 for all comparisons). Again, as the DoF decreased in the fabricated COMatrices, lower BPs were recorded for each injury model (Figure 4F to 4I). Moreover, the recorded BPs for 1 mm punch, 2.75 mm cut, and 5.9 cut penetrating injuries repaired with cyanoacrylate were 150±80 mmHg, 271±43 mmHg, and 48±16 mmHg, respectively. The recorded BPs for 1 mm punch, 2.75 mm cut, and 5.9 cut penetrating injuries repaired with 20% GelMA were 124±49 mmHg, 259±51 mmHg, and 95±33 mmHg, respectively. Since, 2x LC-COMatrix showed superior characteristics in the above experiments, it was used for further in vitro, ex vivo and in vivo experiments.
2.5. Cytocompatibility of Light-Curable COMatrix Hydrogel in vitro
Biomaterials applied for corneal repair should be biocompatible with the most abundant cell types in the cornea, namely epithelial cells and stromal cells. Corneal epithelial cells typically grow over the surface while corneal stromal cells migrate into the applied biomaterial. The viability of human corneal epithelial cells (HCECs) and human corneal mesenchymal stem cells (hcMSCs) seeded on the cross-linked LC-COMatrix and thermo-gelated COMatrix was evaluated with a live-dead assay. As presented in Supplementary Figure S4, both HCECs and hcMSCs showed more than 95% viability in the construct. Evaluation of the number of viable cells at days 1, 4, 9 and 15 by metabolic assay revealed that both HCECs and hcMSCs had increased rate of proliferation until day 9, after which the cells went into steady growth from day 9 to day 15 on both COMatrix and LC-COMatrix (Supplementary Figure 5B and 5D).
One of the main concerns regarding the interaction of a biomaterial and mesenchymal stromal cells is their transdifferentiation into smooth muscle-like cells, specifically, myofibroblasts, which are the main mediators of corneal fibrosis/scarring.[20] To evaluate the effect of LC-COMatrix on myofibroblast formation, LC-COMatrix combined with hcMSCs was cured with green light after which the cross-linked hydrogel (containing the cells inside) was cultured for 2 weeks. After two weeks the hydrogel disks were stained for the expression of CD90, as a marker of hcMSCs, ki-67 marker, as a marker of cell proliferation, and α-SMA (α-smooth muscle actin), as a marker of myofibroblasts. Ki-67 marker was strongly expressed in the CD90 positive hcMSCs indicating active cell proliferation (Supplementary Figure 5E). On the other hand, no expression of α-SMA was detected in the CD90 positive hcMSCs (Supplementary Figure 5F), indicating that the human corneal mesenchymal stem cells had not transdifferentiated into smooth muscle-like cells.
2.6. Retention of Light-Curable COMatrix in a Human Corneal Stromal Defect ex vivo
To explore the retention of LC-COMatrix applied for repair of the corneal stroma, cadaveric human corneas with stromal defects were utilized. As presented in Figure 5A, an anterior lamellar cut with a diameter of 10 mm and thickness of 300 μm was made in cadaveric human corneas and the anterior flap was removed. Then, the created corneal stromal defect was repaired with 2x LC-COMatrix and cured with green light for 4 minutes. The repaired corneas were placed in standard corneal tissue containers and rotationally shook at 37° C while a thin layer of corneal preservative solution flowed over the repaired area (Supplementary Figure S5). The repaired corneas were followed up with slit-lamp bio-microscopy, optical coherence tomography (OCT) and pachymetry to track the transparency, structure, and thickness map of the repaired human corneas, respectively. As presented in Figure 5B, LC-COMatrix consistently repaired the human corneal stromal defect with a smooth surface with a comparable transparency to native human corneas. During the 30-day incubation of the repaired corneas under constant flow of corneal preservative solution, no sign of detachment was observed on OCT imaging. Moreover, the thickness of the repaired corneas remained stable for 30 days as evident by the results of pachymetry (Figure 5B). On the other hand, the follow up of human corneas with lamellar stromal defects repaired with fibrin glue showed that the fibrin glue had degraded by day 15 (Supplementary Figure S6). In the corneal defects repaired with 20% GelMA, the gels had contracted to the center of the corneal stromal defect during follow-up (Supplementary Figure S6). Another observed difference between 2x LC-COMatrix and 20% GelMA on OCT imaging was the similarity of LC-COMatrix to human cornea in terms of its optical reflectivity, in contrast to GelMA which demonstrated a significant difference with native corneal tissue (Figure 5 and Supplementary Figure S6). These observations suggest greater resemblance of LC-COMatrix to native corneal tissue compared to GelMA.
2.7. Repair of Rabbit Corneal Stromal Defect by Light-Curable COMatrix
An in vivo rabbit corneal stromal defect was created with a 3 mm lamellar keratectomy technique (Illustrated in Figure 6A, N=4). The partial thickness stromal defect was then filled with LC-COMatrix, covered with a contact lens to make the hydrogel even with the surrounding corneal tissue, followed by curing with green light (Supplementary Video S10). As presented in Figure 6B, the slit lamp bio-microscopy and fluorescent staining showed rapid recovery and closure of corneal epithelium over the applied LC-COMatrix with remarkable transparency of the repaired area during the 28 days follow-up. The OCT imaging during the follow-ups showed full thickness repair of corneal stroma with progressive improvement in the congruency between the repaired area and the surrounding native cornea tissue (Figure 6C). Comparing the thickness (pachymetry) measurements of the cornea immediately after creating the defect (day 0) to the thickness on day 28 showed substantial repair (restored thickness) of the corneal stroma by LC-COMatrix (Figure 6D). The central corneal thickness (CCT) at last follow-up (day 28) was 397±12 μm, which had no statistically significant difference with same corneas’ CCTs before performing the surgery (399±8 μm, N=4, Supplementary Figure S7). The results of examination of each rabbit are presented in Supplementary Table S1.
2.8. Repair of Corneal Perforation in Rabbit Eyes using LC-COMatrix in vivo
An in vivo rabbit corneal macro-perforation model was created to assess the potential of LC-COMatrix for repairing corneal full thickness defects. As illustrated in Figure 7A and in Supplementary Video S11, a partial (~50–60%) thickness layer of the rabbit cornea was removed by a 3 mm diameter lamellar keratectomy. A full-thickness cut was then made in the center of the stromal defect using a 1 mm dermal punch and the tissue was removed (N=4). LC-COMatrix was applied to the stromal defect area followed by green-light curing (Supplementary Video S11). The administered LC-COMatrix formed strong adhesion to the cornea defect and terminated the leakage of the anterior chamber fluid.
As shown in Figure 7B, after creating the perforation, the anterior chamber collapsed due to leakage of fluid and the iris and lens were found to be touching the cornea. Following closure of the corneal perforation with LC-COMatrix, the anterior chamber deepened at all follow-ups (Figure 7C). Part of the iris remained adherent to the repaired area in 3 rabbits and was fully detached in the other one (shown here). The corneal epithelium healed over the defect area after about a week as no fluorescein staining was observed at day 14 of follow-up. The intraocular (IOP) pressure in the surgical eyes had no significant difference with the fellow eye during the follow-up (Figure 7D). Moreover, the CCT at last follow-up (day 28) was 447±12 μm, which is significantly higher than CCT of the same corneas before performing the surgery (396±11 μm, N=4, p<0.0001, Supplementary Figure S7). The observed difference is due to administration of higher amount of LC-COMatrix to repair the macro-perforation compared to the amount applied for repair of stromal defect to ensure efficient sealing of the perforation. The results of examination of each rabbit are presented in Supplementary Table S1.
2.9. Histological Evaluation and Immunostaining of Repaired Rabbit Corneas
Histology of the repaired rabbit corneas showed some differences between the macro-perforation model and the corneal stromal defect model. Specifically, the stromal architecture at the site of repair was lamellar in the perforation model, similar to the control cornea (Figure 8A) while it was less lamellar in the corneal stromal defect model at day 28 of follow up. This is the first study reporting the histological characteristics of a repaired corneal macro-perforation with a novel light-curable bio-adhesive. In both models the corneal epithelium regrew over the repaired area and looked similar to the native control corneal epithelium (Figure 8A). Immunofluorescent staining with the differentiation and stratification marker of corneal epithelial cells, CK-12,[21] revealed that the regrown corneal epithelium on the surface of the repaired area with LC-COMatrix (the applied LC-COMatrix has weak autofluorescence marked with orange stars in Figure 8B) was multi-layered and fully differentiated and stratified toward mature corneal epithelial cells in the superficial layers (orange arrows in Figure 8B).
The keratocyte marker, KERA (keratocan), is expressed in the stromal cells in native cornea (orange arrows in Figure 8A top pane). This marker was highly positive in the middle of the repaired area (like a strip) in the macro-perforation model (orange stars in Figure 8C middle pane), while the native KERA positive cells under the KERA-positive strip (orange arrows in Figure 8C middle pane). α-SMA (α-smooth muscle actin) had the same pattern of expression as KERA, like a strip in the repaired macro-perforated corneas consistent with a scar-like appearance (orange stars in Figure 8D middle pane). A remodeled native-like corneal stroma is observable on top of the KERA and α-SMA positive areas, hashtag (#) markers in Figure 8C and 8D, middle panes.
KERA positive cells (orange arrows in Figure 8C bottom pane) are present close to the applied LC-COMatrix (orange stars in Figure 8C bottom pane) in repaired corneal stromal defect. The expression of α-SMA in repaired partial-thickness corneal stromal defects is similar to control native cornea, indicating that LC-COMatrix did not induce any further transdifferentiation of keratocytes to myofibroblast-like cells.
3. Discussion
Novel therapeutic approaches are emerging to overcome the issue of donor cornea shortage, such as keratoprosthetics (artificial cornea)[22] and other collagen-based constructs.[23] Most studies have focused on mimicking the unique characteristics of corneal tissue such as transparency and distinctive biomechanical properties by using natural biomaterials such as combinations of collagens, gelatin, chitosan and/or alginate.[24] In addition to a corneal stromal substitute, there is a need for a robust tissue-incorporating bio-adhesive for closing and repairing corneal defects and macro-perforations following severe injuries or infectious/inflammatory diseases. The significance of such a tissue-incorporating bio-adhesive is more highlighted in underserved areas and battlefields where advanced surgical infrastructures are not available; and the injured eye must be stabilized to prevent permanent blindness due to tissue necrosis or severe infections (e.g. endophthalmitis).
The goal of this study was to develop and characterize a modified version of a previously reported thermoresponsive COMatrix hydrogel from decellularized porcine corneas.[13, 15] The novel modification of COMatrix hydrogel has several advantages over chemical cross-linking methods which include maintaining the natural corneal composition, with improved bio-physical characteristics such as easy handling and administration, fast controllable in-situ cross-linking, malleability, and significantly enhanced mechanical stability. The light-curable form of COMatrix has the potential to be administrated as an in-situ corneal stromal regenerative material in addition to application as a bio-adhesive for closing and repairing corneal macro-perforations or incisions following surgeries and trauma. LC-COMatrix has a suitable consistency (e.g., viscosity) for application to the defect area without unnecessary spreading to surrounding areas. Following application, LC-COMatrix can be cured with a green light source such as a battery powered LED or the standard green light filter present on most slit-lamp bio-microscopes. This composition has a similar mechanism of polymerization (visible light curing) with GelMA, a recently introduced bio-adhesive for corneal repair.[7] The reported adhesiveness parameters in this study for 20% GelMA (4 minutes light-curing) are 225.8±32.3 mmHg for ex-vivo burst pressure on porcine corneas’ substrates and 90.4 ± 10.2 kPa for adhesion strength on porcine skins’ substrates. More recently, another type of light-curable gelatin has been fabricated by grafting glycidyl methacrylate on the gelatin with improved adhesiveness properties compared to GelMA.[25] Here we showed superiority of LC-COMatrix in terms of adhesiveness properties compared to GelMA. However, the discrepancies with other reports are potentially related to several different parameters in fabrication and formulation of bio-adhesives and settings of performed tests. In terms of formulation, LC-COMatrix has been fabricated by decellularization and processing of porcine corneas by preserving the collagens and sGAGs to represent the natural cornea ECM; however, GelMA is a collagen-only material which is usually derived from porcine skin that is not representative of corneal macromolecular structure. We have previously shown with proteomic analyses that COMatrix is composed of ECM regulatory proteins such as keratocan and lumican which can potentially promote regeneration of the cornea.[13a]
Current commercially available products such as fibrin sealants (e.g. VISTASEAL™, TISSEEL™), and PEG-based bio-glues (ReSure®, OcuSeal®) need extensive pre-application preparation, which includes thawing, dissolving and mixing. Moreover, the cross-linking reaction of these products is not controllable. In contrast, LC-COMatrix does not require any pre-application preparation. It is a ready-to-apply syringe like ViscoElastic products that does not require pre-application warming or mixing and it can be applied in a wide range of temperatures in emergency situations. Following application LC-COMatrix can be further manipulated before light-curing (e.g. to make the surface more even with the surrounding tissues) while the cross-linking reaction can be controlled by the intensity and duration of light-curing. In addition, LC-COMatrix has a favorable consistency and can be applied in upright patients (behind slit lamp) without spilling or running off.
In addition to GelMA,[7, 19a] a fibrin-based biomaterial has been introduced for in-situ repair of corneal stromal defects.[9a] Like GelMA, this fibrin-based product needs pre-application warming and requires mixing of the pre-polymer with cross-linker prior to application. Moreover, it has a very low viscosity (31.7 ± 27.6 Pa.s) and would not be suitable for superficial applications or in patients who are upright (similar to GelMA, Figure 3). The measured burst pressure of this product using a porcine cornea as the substrate is 170±16.9 mmHg which is considerably lower than reported burst pressure of LC-COMatrix. Griffith, M. et al repaired an in vivo corneal perforation in a model similar to that in this study using a fibrin-based product which required multiple applications.[9a] In contrast, LC-COMatrix had to be applied only once, and no secondary repair was required. From follow-up of both corneal perforations repaired by the fibrin-based product by Griffith et al and LC-COMatrix, the repaired area became opaque (Figure 7B). However, this study is the first study presenting the histological evaluation of repaired macro-perforation by a light-curable bio-adhesive. We believe that the reason for low transparency of the closed/repaired areas may be due to invasion of blood vessels from the attached iris and also direct contact with the aqueous humor which in turn promotes inflammation and development of myofibroblast-like cells (Figure 8D). Additional studies with longer follow-up are needed to determine if there is late remodeling which can reduce the opacity (since a native-like corneal stroma is observable on top of the α-SMA positive area, hashtag (#) markers in Figure 8C and 8D, middle panes) or whether its development can be mitigated, for instance, by limiting the extent of inflammation with corticosteroids. Moreover, since LC-COMatrix can potentially enter the anterior chamber when repairing full thickness perforations, it is necessary in future studies to assess its cytocompatibility with human corneal endothelial cells.
Keratocytes mediate the regeneration of corneal stroma by producing extracellular matrix elements. In the corneal lamellar keratectomy model, the central aspect of the applied LC-COMatrix was not invaded by a high number of keratocytes and they were observed primarily near the edge of the repaired defect (Figure 8C). Future long-term studies of corneal stromal repair by LC-COMatrix are likewise necessary to evaluate the migration and remodeling of the repaired stroma. Overall, the lack of significant inflammation and myofibroblast formation in the non-penetrating stromal defect model, supports the biocompatibility of LC-COMatrix.
Finally, the COMatrix presented in this study is a xenogeneic product which raises concerns regarding disease transfer from animals to human recipients. Few porcine derived products have been successfully translated into clinical practice or are under evaluation in clinical trials. Pig-derived cardiac valves have been successfully translated into clinical practice.[26] Moreover, a hydrogel fabricated from porcine heart is under investigation in clinical trial phase I/II and promising safety and efficacy was reported.[27] Removing the galactose-α1,3-galactose (α-Gal) and N-glycolylneuraminic acid (NeuGc) epitopes reduce the risk of immunologic response in recipients, which should be addressed before translation of this product into clinical experiments. Previous studies have shown remarkable efficiency of decellularization methods for removing alpha-gal epitope, which could be improved by using alpha-galactosidase enzyme.[28] Moreover, recent advances in developing genetically modified pigs lacking both α-Gal and NeuGc have paved the way for whole organ transplantation and likewise fabrication of products from decellularized extracellular matrix.[29]
4. Conclusion
All in all, LC-COMatrix not only compares well to the other state of the art products but also has superior advantages including natural corneal tissue representativeness, user-friendly preparation and application, and non-temperature dependent stable viscosity. Therefore, it has great potential for future modifications and expansion of its applications in ocular surgeries, cell and drug delivery, tissue engineering and three-dimensional bio-printing.
5. Experimental Section
5.1. Fabrication of Light-Curable Porcine Cornea Extracellular Matrix Hydrogel (Light Curable-COMatrix)
5.1.1. Harvesting and Decellularization of Porcine Corneas
Porcine eyeballs were obtained from a certified abattoir (Park Packing CO, Chicago) and transferred to the lab on ice. The eyeballs were then soaked in PBS containing 2% gentamicin and the corneas were excised. The harvested corneas were cut into 2×2 mm pieces and washed with PBS and sterile water. Then, the porcine cornea tissue fragments were transferred to a 50 ml conical tube containing 35 ml of 10 mM Tris-HCl contained protease inhibitor cocktail per manufacturer recommended concentration (cOmplete™, EDTA-free Protease Inhibitor Cocktail, Roche). After that, the tube underwent 9 cycles of freeze (−80°C)-thaw (37°C) in 9 days (one cycle per day). After freeze-thawing the tissue fragments were washed with pure water and then incubated in DNAse (50 mM Tris-HCl containing 7.5 U/ml deoxyribonuclease (Sigma, USA)) cocktail for 16 hours at 37°C. The bioburden of the decellularized porcine corneas were then decreased by stirring in 4% ethanol and 0.1% per-acetic acid in pure water for 20 hours. The tissues pieces were washed for another 48 hours in pure water and then lyophilized for 3 days. The lyophilized decellularized porcine corneas were kept at −80°C for no more than a month before next step.
5.1.2. Cryo-Pulverization and Digestion of Decellularized Porcine Corneas
The lyophilized and decellularized porcine cornea tissue pieces were cryo-pulverized using Spex 6700 freezer-mill. The pulverized tissue was then digested with pepsin/HCl by ratio of 20 mg decellularized ECM to 1 mg >400 U pepsin in 0.1 M HCl for 72 hours at room temperature. At the end of digestion when no more tissue particle was detectable, the solution was neutralized to pH of 7.5 with NaOH and 10x PBS. By neutralization of the solution pH, the pepsin enzyme is deactivated.[30] The result of this step is a thermoresponsive hydrogel, COMatrix hydrogel, that has thermo-gelation properties at 37° C.[13]
5.1.3. Functionalization of Decellularized and Digested Porcine Corneas
The thermoresponsive COMatrix was reacted with methacrylate anhydride (MA) with different w/w ratios (2:1,”0.5x”, 1:1, “1x”, and 1:2, “2x”). The MA was added dropwise and the pH was adjusted to 7.5. The reaction was accomplished at 4°C for 12 hours. Then, the solution was 5-times diluted with PBS and dialyzed against deionized water for 4 days using 12–14 MWCo dialysis tubes (Sigma). At the end of dialysis, the samples were snap-frozen in liquid nitrogen and lyophilized for 3 days.
5.1.4. Fabrication of Light-Curable COMatrix Hydrogel
To formulate the light-curable COMatrix hydrogel, a visible light photo-initiating system was used. The photo-initiating cocktail was prepared by dissolving Eosin Y (0.1 mM final concentration), Triethanolamine (TEOA, 0.75% w/v final concentration) and N-Vinylcaprolactam (VC, 0.5% w/v final concentration) in 1x PBS. The functionalized COMatrices with different ratios (0.5x, 1x, and 2x) were then dissolved in photo-initiating cocktail (25 mg/ml) to make the ready-to-cure light-curable (LC)-COMatrix. The prepared LC-COMatrices were then loaded in 1 ml syringes with luer-locks and stored at 4°C for future experiments no more than two weeks. To apply the LC-COMatrices, a 22-gauge angled cannula was used. Light curing was performed using a custom-made light source fabricated by green LEDs (520 nm, 30° Beam angel) with emission of 100 μW/cm2 (Supplementary Figure S1). We found that 4 minutes green light-curing provided an optimal cross-linked LC-COMatrix. The GelMA hydrogel was fabricated as previously reported.[7, 31] 20% (w/v) GelMA combined with the same concentration of photo-initiating cocktail to LC-COMatrix mixture was utilized for perfumed experiments.
5.2. Characterization of Light-Curable COMatrix Hydrogel
5.2.1. Compositional Characterization
The collagen and sGAG composition of the fabricated light-curable and thermoresponsive COMatrices, GelMA and human corneas (Eversight, Illinois) were measured using previously described methods.[13a]
5.2.2. Measuring the Degree of Functionalization
To confirm the derivatization of the methacrylate groups and to measure the degree of functionalization (DoF) in fabricated 0.5x, 1x and 2x LC-COMatrices, 1H NMR (Nuclear magnetic resonance) and fluoraldehyde assay were used as previously reported.[32]
Standard proton NMR techniques were utilized to confirm the conjugation of the methacrylate to the COMatrix molecules. Similar concentrations of 0.5x, 1x and 2x LC-COMatrix and COMatrix samples (0.5 mg/ml) from the same batches were used. All experiments were conducted at 298 K on a Bruker 600 MHz AVANCE III NMR spectrometer operating with a 5mm D-CH cryogenic probe equipped with a z-axis pulsed field gradient. 1D proton spectra were acquired using the standard 1D version of the NOESY experiment with pre-saturation of water using a total of 512 scans, a sweep width of 16 ppm, acquisition time of 2 s, and a 10 s relaxation delay. Calibration of the proton 90° pulse was verified by null signal of a 360° pulse. Spectra were processed with manual phasing and peak integration.
To measure the DoF of 0.5x, 1x and 2x LC-COMatrices using the fluoraldehyde assay, the COMatrices from the same batch were used to draw the standard curve. In brief, the LC-COMatrices (N=4) were dissolved in PBS (0.5 mg/ml) and the same batch of COMatrices were dissolved in PBS (0.05, 0.1, 0.5, 1 and 2 mg/ml). Then, 300 μl of each samples and PBS (control) were mixed with 600 μl of room temperature fluoraldehyde reagent solution (Sigma) for 1 min. After that, 250 μl of each mixture was loaded triplicate in an opaque 96-well plate and the fluorescence intensities were measured at 450 nm with excitation at 360 nm. At the end, the average intensity of PBS was deducted from average intensity of LC-COMatrix and COMatrix (standard) samples. The linear calibration curved was drawn using the COMatrix fluorescence intensities and the DoFs for 0.5x, 1x and 2x LC-COMatrices were calculated using the standard curve.
5.2.3. Dry Weight and Swelling Behavior of Light-Curable COMatrix
To create round disc-shaped constructs, 80 μl of COMatrix or 0.5x, 1x or 2x LC-COMatrix, or 20% GelMA was loaded in a 7 mm diameter PTFE ring (520 μm thickness). The COMatrix samples was incubated at 37°C for 30 minutes to set as a gel, while the light curable COMatrices and 20% GelMA were cured with green light for 4 minutes. Same amount of fibrin glue (prepared based on the manufacturer instructions, TISSEEL Fibrin Sealant, Baxter) was loaded into the ring and incubated at 37°C for 30 minutes for full reaction. Cadaveric human corneas (Eversight, Illinois, https://www.eversightvision.org/) with average thickness of 500 to 550 μm were also cut with a 7 mm diameter trephine. All samples were first washed briefly with PBS, weighted (W0) and then put in 500 μl PBS and incubated at 37°C. The weight of samples was followed at days 1 (W1), 7 (W7) and 18 (W18) after wiping the outside solution using a kimwipe (KIMTECH). At the end of follow-up, all samples were incubated in an oven at 90°C for 3 hours until fully dry and then weighted to measure the dry weight (DW) of each sample. The water content (%) of each sample (N=3) at each day was then calculated by using the weight at each day of follow-up (Wd) and the following equation:
The change in water content in each day was then plotted to map the swelling behavior.
5.2.4. Enzymatic Degradation of Light-Curable COMatrix
To track the degradation of LC-COMatrix compared to COMatrix, fibrin glue, 20% GelMA and human cornea with collagenase, the samples were molded and prepared as explained above. Then each sample (N=3) was incubated in 200 μl of bacterial collagenase type 1 (Sigma, 5 U/ml in 50 mM TES and 0.36 mM Calcium chloride), as the common protocol to assess the degradability of a developed biomaterial for cornea regeneration.[33] Each sample was weighted on days 0, 1, 2, 5 and 10 and the weight change (%) was calculated.
5.2.5. Evaluating Displacement of LC-COMatrix by Gravity
To evaluate the effect of gravity on spreading of the LC-COMatrix, a gravity displacement test was performed. The 2x LC-COMatrix, ophthalmic viscoelastic, fibrin glue, 20% GelMA and cyanoacrylate were applied on an upright cadaveric human cornea mounted on a slit-lamp (to simulate the same condition to apply the bio-adhesive on a patient cornea in clinic). Video recording was performed from administration of the samples (0 s) to 5 minutes later (300 s). Moreover, the covered area with each bio-adhesive immediately after administration and after 5 minutes was measured by image analysis (N=3) using ImageJ software (National Institutes of Health, Bethesda, MD, https://imagej.nih.gov/ij/). The change in the covered area (%) was calculated using the following formula:
5.2.6. Rheological Characterization and Viscosity Measurement of LC-COMatrix
To measure the viscosity of 2x LC-COMatrix and 20% GelMA, the hydrogel was loaded in a rotational rheometer (Kinexus Ultra+, Malvern) with a parallel 25 mm plate and temperature controller. The gap was set to 0.4 mm and the viscosity (PaS) was recorded with shear rate change from 0.01 to 1000 (S-1) at different temperatures (12, 25 and 37° C). The same recording setting was used for fibrin glue (TISSEEL) and Ophthalmic ViscoElastic Agent (sodium chondroitin sulfate / sodium hyaluronate ophthalmic, Alcon Laboratories, Inc). The recorded viscosities were plotted against shear rate.
5.2.7. Rheological Photo-Gelation Kinetics and Characterization of LC-COMatrix
The 0.5x, 1x and 2x LC-COMatrices and 20% GelMA were loaded on a quartz bed of a rotational rheometer (Kinexus Ultra+, Malvern) with a parallel 25 mm plate and a custom-made green light source. The gap was adjusted to 0.4 mm and the shear moduli (storage, G’ and loss, G”) were recorded with a frequency of 0.159 Hz and strain of 5%. After one minute of recording the green light was turned on while recording continued and later the light was turned off at minute 5. The recording was continued for another 5 minutes. All the above tests were also performed on fibrin glue prepared per manufacturer instructions and incubated for 30 minutes for full reaction.
5.3. Ex Vivo Bio-Adhesion Strength Measurements
The bio-adhesion strength of 0.5x, 1x, and 2x COMatrices and 20% GelMA were measured using fresh cadaveric human corneas as substrate (Eversight, Illinois, https://www.eversightvision.org/).[34] The human corneas (average thickness of 500 μm) were cut using a 10 mm trephine and then cut into two halves. Each half was loaded on an already half-cut contact lens holder to preserve the cornea curvature. As illustrated in Figure 4A, 2 mm of half-corneas was in touch with half-contact lens holder secured with cyanoacrylate glue (Krazy Glue, Elmer’s Products Inc., Columbus, OH). The contact lens holder was secured in grips of a mechanical testing machine (225lbs Actuator equipped with a 5 N load cell, TestResources) and aligned with a 1 mm gap. Then, the LC-COMatrices were loaded in between the half-corneas with a length of 3 mm and thickness of 0.5 mm using a 22-gauge angled cannula. After that, the LC-COMatrices and 20% GelMA were cured with a green-light source for 4 minutes. The tensile test was run at the rate of 1 mm/min and the adhesion strength (MPa) was calculated using the highest recorded load (N) divided by the surface area (3 mm × 0.5 mm)).
5.4. Ex Vivo Burst Pressure Measurements
The ex vivo sealing capabilities of the 05x, 1x and 2x, LC-COMatrices and 20% GelMA were evaluated using a burst pressure measurement setup. The fresh cadaveric human corneas (Eversight, Illinois, https://www.eversightvision.org/) were loaded in an artificial anterior chamber (CORONET®) connected to a same-level pressure sensor and pump. Four different types of controlled corneal injuries were created on the cadaveric human corneas (at pressure of 18 mmHg) including 1- and 2-mm punch full thickness injury with the cut cornea tissue removed after punching; and, 2.75 and 5.9 mm cut injuries made by 2.75 mm keratome and scalpel (size 11) knives, respectively. After removing the air in the chamber and drying the area of injury, the COMatrices and GelMA were applied using a 22-gauge cannula and cured with green light for 4 minutes (Figure 4). Then, the pressure was increased by forward movement of the plunger of a 20 ml syringe loaded with blue colored PBS with speed of 1 ml/min until burst/failure visualized in the video being recorded from top. 2x LC-COMatrix showed the best performance in the characterization and ex vivo experiments; so, it has been used for further in vitro, ex vivo and in vivo experiments.
5.5. In vitro Cytocompatibility of Light-Curable COMatrix with Human Corneal Epithelial and Stromal Cells
Immortalized human corneal epithelial cells (HCECs) were kindly provided by Dr. Deepak Shukla (Illinois Eye and Ear Infirmary, University of Illinois at Chicago).[35] The HCECs were expanded in high-glucose DMEM medium (4500 mg/L, Fisher Scientific, USA) containing 10% FBS (Fisher Scientific, USA) and 1x Antibiotic-Antimycotic (Fisher Scientific, USA) for no more than 40 passages. The human corneal MSCs (hcMSCs) were obtained from cadaveric human corneas as described before by our group.[36] In brief, the centers of cadaveric human corneas (Eversight, Chicago) were cut with 8 mm trephine and the periphery (containing the limbal area) was cut into 4 pieces. Each piece was then put in a well of 6 well plate until the hcMSCs were outgrow. The outgrown cells (P0) were collected and expanded. hcMSCs with passage 3 and 4 were used for further experiments. The α-MEM medium (Fisher Scientific, USA) containing 10% Fetal Bovine Serum (Fisher Scientific, USA) and 1x Antibiotic-Antimycotic (Fisher Scientific, USA) was used in all experiments with hcMSCs.
We have previously shown the cytocompatibility of thermoresponsive COMatrix.[13] In this study, we evaluated the cell compatibility of 2x Light Curable-COMatrix compared to thermoresponsive COMatrix. The cell-free thermo-gelation was induced as previously described by incubating the tissue culture plate at 37° C for 30 minutes (75 μl COMatrix, 25 mg/ml, was loaded in each well of a 48 well plate, N=3). The cell-free photo-gelation of 2x LC-COMatrix was induced by curing the hydrogel loaded in 48 well plate (25 mg/ml, 75 μl in each well) with green light for 4 minutes. Then, the HCECs or hcMSCs (3×103 cells) were seeded on top of the gel formed COMatrices using the above-mentioned media for each cell type (2D cell culture).
For 3D cell culture, the hcMSCs (3×104 cells) were mixed with 80 μl of 15 mg/ml 2x LC-COMatrix, loaded in a well of a 48 well plate and cured with green light for 2 minutes. Then, 300 μl of α-MEM media containing 10% FBS and 1x antibiotic was added to each well. The hydrogels were cultured for two weeks.
5.5.1. Live-Dead and Metabolic Activity Assays
To monitor the viability and number of two-dimensional seeded HCECs and hcMSCs on COMatrix and LC-COMatrix, live-dead and metabolic activity assays were performed, respectively. On days 1, 4, 9 and 15, the cells were stained with Calcein-AM (live cells), propidium iodide (PI, dead cells) and Hoechst 33342 (total cells, all from Sigma, USA) for 1 hour by incubating at 37°C in humidified atmosphere air with 5% CO2. The cells were imaged using ZEISS Cell Observer SD Spinning Disk Confocal Microscope (Zeiss, Germany). The metabolic activity of cells as representative of cell numbers was also assesses using Cell Counting Kit-8 (CCK-8, Sigma, USA) per the manufacturer’s recommendation.
5.5.2. Immunofluorescence Staining
The 2x LC-COMatrices combined with hcMSCs cultured for 2 weeks were fixed in 4% paraformaldehyde (PFA) for an overnight and embedded in optimal cutting temperature (O.C.T, TissueTek) and frozen on dry ice. The fixed hydrogels were sectioned by Cryostat (Fisher Scientific, USA) and transferred on a histological slide. The slides were then fixed with 4% PFA for 15 minutes and washed with PBS. The samples were blocked with 3% bovine serum albumin (BSA) for an hour and incubated with primary antibodies (anti-CD90, anti-Ki-67 and anti-α-SMA) overnight (The details of all utilized antibodies in this study are available in Supplementary Table S2). Then, the sections were washed with PBS and incubated with secondary antibodies for 1 hour at room temperature (Supplementary Table S2). After several rounds of washing the slides were mounted with ProLong™ Gold Antifade Mountant with DAPI (Thermo Fisher Scientific) and visualized with a confocal microscope (LSM 710, Carl Zeiss, Germany). The Images were analyzed with ZEN Lite software (Zeiss, Germany).
5.6. Ex Vivo Retention of Light-Curable COMatrix in Human Corneal Stromal Defect Model
As shown in Figure 5A, an anterior lamellar cut (10 mm diameter, 300 μm thickness) was made in cadaveric human corneas and the anterior stromal flap was removed. The created defects were then repaired with 2x LC-COMatrix (25 mg/ml) or 20% GelMA and cured with green light for 4 minutes. The corneas (N=3) were placed in donor cornea holders containing 9 ml of Life4C (donor cornea preservative solution) and put on an orbital shaker upside down (Supplementary Figure S5, the corneas were facing up with a layer of solution covering them). After that, the shaker was in a 37° C incubator starting with 50 orbital shakes per minute. The human corneas were then follow-up with slit-lamp bio-microscopy, optical coherence tomography (OCT) and pachymetry to evaluate the adhesiveness/attachment, transparency, morphology and thickness of the repaired corneas with LC-COMatrix for 30 days. The human corneal stromal defects were also repaired with fibrin glue as control.
5.7. Rabbit Corneal Perforation and Stromal-Defect Models and Repair with Light-Curable COMatrix
All animal experiments were performed in accordance with guidelines of Association for Research in Vision and Ophthalmology (ARVO) and were approved by the University of Illinois Biologic Resources Laboratory (BRL). All surgeries were performed by the same surgeon (G.Y.). New Zealand rabbits were anesthetized using sub-cutaneous (SC) injection of Ketamine (45 mg/kg) and Xylazine (5 mg/kg), and a drop of proparacaine 0.5% was instilled into the right eye. Then, povidone-iodine 1% was applied to the eye and removed after 30 sec with a sterile sponge. A sterile drape covered the right eye surrounding area.
To create the partial thickness corneal stromal-defect model (N=4), the anterior lamellar keratectomy was performed by a 3 mm trephination (150–170 μm depth) at the center of cornea followed by performing the lamellar keratectomy using a 1.2 mm angled mini-crescent knife (Figure 6A and Supplementary Video S10). Then, proper amount (10–20 μl) of the 2x LC-COMatrix pre-loaded in a syringe (Supplementary Figure S1) was applied using a 22-gauge blunt cannula and trimmed. After that, an 8 mm diameter contact lens was fit on the defect area to adjust the hydrogel with surrounding tissues, and the repaired area was cured with visible green light for 4 minutes. A 14 mm contact lens was applied on the cornea for at least 24 hours.
To create the full thickness corneal perforation model (N=4, Figure 7A and Supplementary Video S11); first, a partial thickness lamellar keratectomy was performed as explained above. Then, by using a 1-mm punch biopsy, a full thickness cut was performed at the center of the lamellar keratectomy area and the tissue was removed using a mini-crescent knife (if needed). After drying the drained fluid from the anterior chamber, the created perforation defect was repaired with 2x LC-COMatrix (20–40 μl, applied using a pre-loaded syringe with a 22-gauge blunt cannula, Supplementary Figure S1) and cured with green-light for 4 minutes. After assuring no leakage, a 14 mm soft contact lens was placed on the eye and kept for at least 24 hours.
The eyes from both corneal injury models were treated with a combination eye drop containing dexamethasone, neomycin and polymyxin B for 7 days after surgery, 2 times per day. The follow ups were performed with OCT imaging and pachymetry, slit lamp bio-microscopy and fluorescein staining for 30 days. The intraocular pressure (IOP) of the eyes (corneal perforation model) was also measured using a handheld Tonometer (iCare Tonometer) during the follow-ups.
5.8. Histological Evaluations and Immunofluorescence Staining
After humanly euthanizing of the rabbits with pentobarbital overdose (1 ml/ 10 lbs, IV) under anesthesia (ketamine/xylazine, SC), the corneas were removed and fixed in 4% paraformaldehyde (PFA) overnight. Then, the tissues were washed with PBS and dropped in 15% sucrose solution in PBS until they sank and then dropped in 30% sucrose solution in PBS until they sank. After that, the samples were embedded in O.C.T and frozen on dry ice, and sectioned by Cryostat (Fisher Scientific, USA) and transferred on a histological slide for staining. The hematoxylin and eosin staining was performed as described earlier.[13b] The immunofluorescence staining was performed as described above using the primary antibodies summarized in Supplementary Table S2.
Statistical Analysis
Data are shown as mean ± standard deviation (SD). No pre-processing was performed on the collected data. Statistical analyses were done by GraphPad Prism software version 8.3.0 (538) for Windows, (GraphPad Software, San Diego, California, USA, www.graphpad.com) using Student’s t-test for comparing the means between two groups and one-way analysis of variance (ANOVA) and Tukey posttest for more than two groups (sample size (N) for each test is mentioned in Experimental Section, Results and Figure legends. All performed tests were two-sided). P-values less than 0.05 were considered as statistically significant difference between groups.
Supplementary Material
Acknowledgments
The authors want to thank Ruth Zelkha, MSc and Michael Sun, MD, PhD for their help in performing some experiments. This study is extracted from PhD dissertation of GY. A provisional US and international patent has been filed at USPTO on September 2, 2021 by GY, ARD, and The Office of Technology Management at University of Illinois at Chicago.
Funding:
This work was supported by: R01 EY024349 (ARD), R01EY027912 (MIR), Core Grant for Vision Research EY01792 (MIR) from NEI/NIH; Unrestricted Grant to the Department and Physician-Scientist Award (ARD) both from Research to Prevent Blindness; and Eversight.
The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Biographies
Biographies:
Ghasem Yazdanpanah, MD, MPH, PhD is a resident-physician in Ophthalmology at Illinois Eye and Ear Infirmary, Chicago, Illinois. He received his MD/MPH degree in 2015 and his PhD in Biomedical Engineering from Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago in 2021. His research interests are developing and applying translational strategies for ocular and orbital reconstruction. He is currently focused on fabrication, characterization, and clinical translation of novel biomaterials for ocular regeneration and tissue engineering, three-dimensional bioprinting and drug delivery.
Ali R. Djalilian, MD is the Searls-Schenk Professor of Ophthalmology and Visual Sciences, and Adjunct Professor of the Richard & Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois. His clinical and research interests are in ocular surface disease and the development of novel regenerative therapies.
Footnotes
Competing interests: Authors declare that they have no competing interests.
Data and materials availability:
All data are available in the main text or the supplementary materials.
References
- [1].Gain P, Jullienne R, He Z, Aldossary M, Acquart S, Cognasse F, Thuret G, JAMA Ophthalmol 2016, 134, 167. [DOI] [PubMed] [Google Scholar]
- [2].a) Wilson SL, Sidney LE, Dunphy SE, Rose JB, Hopkinson A, J Funct Biomater 2013, 4, 114; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Shi W, Zhou Q, Gao H, Li S, Dong M, Wang T, Jia Y, Dong C, Wang X, Guo Z, Zhao L, Hu X, Xie L, Advanced Functional Materials 2019, 29, 1902491. [Google Scholar]
- [3].Yoon CH, Choi HJ, Kim MK, Prog Retin Eye Res 2021, 80, 100876. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [4].Trujillo-de Santiago G, Sharifi R, Yue K, Sani ES, Kashaf SS, Alvarez MM, Leijten J, Khademhosseini A, Dana R, Annabi N, Biomaterials 2019, 197, 345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [5].Panda A, Kumar S, Kumar A, Bansal R, Bhartiya S, Indian J Ophthalmol 2009, 57, 371. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [6].Papadopoulou DN, Sionga A, Karayannopoulou G, Natsis K, Komnenou A, Mangioris G, Kalpatsanidis A, Manthos A, Georgiadis N, Karampatakis V, Eur J Ophthalmol 2013, 23, 646. [DOI] [PubMed] [Google Scholar]
- [7].Shirzaei Sani E, Kheirkhah A, Rana D, Sun Z, Foulsham W, Sheikhi A, Khademhosseini A, Dana R, Annabi N, Sci Adv 2019, 5, eaav1281. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [8].Li L, Lu C, Wang L, Chen M, White J, Hao X, McLean KM, Chen H, Hughes TC, ACS Appl Mater Interfaces 2018, 10, 13283. [DOI] [PubMed] [Google Scholar]
- [9].a) McTiernan CD, Simpson FC, Haagdorens M, Samarawickrama C, Hunter D, Buznyk O, Fagerholm P, Ljunggren MK, Lewis P, Pintelon I, Olsen D, Edin E, Groleau M, Allan BD, Griffith M, Sci Adv 2020, 6, eaba2187; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Ozcelik B, Brown KD, Blencowe A, Ladewig K, Stevens GW, Scheerlinck JP, Abberton K, Daniell M, Qiao GG, Adv Healthc Mater 2014, 3, 1496. [DOI] [PubMed] [Google Scholar]
- [10].a) Ahearne M, Lynch AP, Tissue Eng Part C Methods 2015, 21, 1059; [DOI] [PubMed] [Google Scholar]; b) Kim H, Park MN, Kim J, Jang J, Kim HK, Cho DW, J Tissue Eng 2019, 10, 2041731418823382; [DOI] [PMC free article] [PubMed] [Google Scholar]; c) Wang F, Shi W, Li H, Wang H, Sun D, Zhao L, Yang L, Liu T, Zhou Q, Xie L, Ocul Surf 2020, 18, 748. [DOI] [PubMed] [Google Scholar]
- [11].a) Saldin LT, Cramer MC, Velankar SS, White LJ, Badylak SF, Acta Biomater 2017, 49, 1; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Dziki JL, Wang DS, Pineda C, Sicari BM, Rausch T, Badylak SF, J Biomed Mater Res A 2017, 105, 138. [DOI] [PubMed] [Google Scholar]
- [12].Sharifi R, Yang Y, Adibnia Y, Dohlman CH, Chodosh J, Gonzalez-Andrades M, Sci Rep 2019, 9, 1876. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [13].a) Yazdanpanah G, Jiang Y, Rabiee B, Omidi M, Rosenblatt MI, Shokuhfar T, Pan Y, Naba A, Djalilian AR, Tissue Eng Part C Methods 2021, 27, 307; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Yazdanpanah G, Shah R, Somala SRR, Anwar KN, Shen X, An S, Omidi M, Rosenblatt MI, Shokuhfar T, Djalilian AR, The Ocular Surface 2021, In Press. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [14].Zhu S, Yuan Q, Yang M, You J, Yin T, Gu Z, Hu Y, Xiong S, Mater Sci Eng C Mater Biol Appl 2019, 96, 446. [DOI] [PubMed] [Google Scholar]
- [15].Fernandez-Perez J, Ahearne M, Sci Rep 2019, 9, 14933. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [16].a) Muzzarelli RA, El Mehtedi M, Bottegoni C, Aquili A, Gigante A, Mar Drugs 2015, 13, 7314; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Hennink WE, van Nostrum CF, Advanced Drug Delivery Reviews 2012, 64, 223. [DOI] [PubMed] [Google Scholar]
- [17].Lee BH, Lum N, Seow LY, Lim PQ, Tan LP, Materials (Basel) 2016, 9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [18].Wu Y, Wenger A, Golzar H, Tang XS, Sci Rep 2020, 10, 20648. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [19].a) Jumelle C, Yung A, Sani ES, Taketani Y, Gantin F, Bourel L, Wang S, Yuksel E, Seneca S, Annabi N, Dana R, Acta Biomater 2022, 137, 53; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Pepelanova I, Kruppa K, Scheper T, Lavrentieva A, Bioengineering (Basel) 2018, 5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [20].Wilson SE, Exp Eye Res 2020, 201, 108272. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [21].Tanifuji-Terai N, Terai K, Hayashi Y, Chikama T.-i., Kao WW-Y, Investigative Ophthalmology & Visual Science 2006, 47, 545. [DOI] [PubMed] [Google Scholar]
- [22].Chhadva P, Cortina MS, Curr Opin Ophthalmol 2019, 30, 243. [DOI] [PubMed] [Google Scholar]
- [23].a) Hong H, Kim H, Han SJ, Jang J, Kim HK, Cho DW, Kim DS, Mater Sci Eng C Mater Biol Appl 2019, 103, 109837; [DOI] [PubMed] [Google Scholar]; b) Hong H, Kim J, Cho H, Park SM, Jeon M, Kim HK, Kim DS, Biofabrication 2020, 12, 045030; [DOI] [PubMed] [Google Scholar]; c) Edin E, Simpson F, Griffith M, Methods Mol Biol 2020, 2145, 169; [DOI] [PubMed] [Google Scholar]; d) Brunette I, Roberts CJ, Vidal F, Harissi-Dagher M, Lachaine J, Sheardown H, Durr GM, Proulx S, Griffith M, Prog Retin Eye Res 2017, 59, 97. [DOI] [PubMed] [Google Scholar]
- [24].a) Chae JJ, Ambrose WM, Espinoza FA, Mulreany DG, Ng S, Takezawa T, Trexler MM, Schein OD, Chuck RS, Elisseeff JH, Acta Ophthalmol 2015, 93, e57; [DOI] [PubMed] [Google Scholar]; b) Calderon-Colon X, Xia Z, Breidenich JL, Mulreany DG, Guo Q, Uy OM, Tiffany JE, Freund DE, McCally RL, Schein OD, Elisseeff JH, Trexler MM, Biomaterials 2012, 33, 8286; [DOI] [PubMed] [Google Scholar]; c) Banitt M, Malta JB, Soong HK, Musch DC, Mian SI, Curr Eye Res 2009, 34, 706; [DOI] [PubMed] [Google Scholar]; d) Rose JB, Pacelli S, Haj AJE, Dua HS, Hopkinson A, White LJ, Rose F, Materials (Basel) 2014, 7, 3106; [DOI] [PMC free article] [PubMed] [Google Scholar]; e) Gratieri T, Gelfuso GM, Rocha EM, Sarmento VH, de Freitas O, Lopez RF, Eur J Pharm Biopharm 2010, 75, 186. [DOI] [PubMed] [Google Scholar]
- [25].Sharifi S, Islam MM, Sharifi H, Islam R, Koza D, Reyes-Ortega F, Alba-Molina D, Nilsson PH, Dohlman CH, Mollnes TE, Chodosh J, Gonzalez-Andrades M, Bioact Mater 2021, 6, 3947. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [26].Godehardt AW, Ramm R, Gulich B, Tonjes RR, Hilfiker A, Xenotransplantation 2020, 27, e12565. [DOI] [PubMed] [Google Scholar]
- [27].Traverse JH, Henry TD, Dib N, Patel AN, Pepine C, Schaer GL, DeQuach JA, Kinsey AM, Chamberlin P, Christman KL, JACC Basic Transl Sci 2019, 4, 659. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [28].a) Choi SY, Jeong HJ, Lim HG, Park SS, Kim SH, Kim YJ, J Heart Valve Dis 2012, 21, 387; [PubMed] [Google Scholar]; b) Gao HW, Li SB, Sun WQ, Yun ZM, Zhang X, Song JW, Zhang SK, Leng L, Ji SP, Tan YX, Gong F, Tissue Eng Part C Methods 2015, 21, 1197; [DOI] [PubMed] [Google Scholar]; c) Kim MS, Lim HG, Kim YJ, Eur J Cardiothorac Surg 2016, 49, 894; [DOI] [PubMed] [Google Scholar]; d) Stone KR, Walgenbach A, Galili U, Tissue Eng Part B Rev 2017, 23, 412. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [29].Cooper DK, Ekser B, Ramsoondar J, Phelps C, Ayares D, J Pathol 2016, 238, 288. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [30].Pouliot RA, Young BM, Link PA, Park HE, Kahn AR, Shankar K, Schneck MB, Weiss DJ, Heise RL, Tissue Eng Part C Methods 2020, 26, 332. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [31].Assmann A, Vegh A, Ghasemi-Rad M, Bagherifard S, Cheng G, Sani ES, Ruiz-Esparza GU, Noshadi I, Lassaletta AD, Gangadharan S, Tamayol A, Khademhosseini A, Annabi N, Biomaterials 2017, 140, 115. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [32].a) Rothrauff BB, Coluccino L, Gottardi R, Ceseracciu L, Scaglione S, Goldoni L, Tuan RS, J Tissue Eng Regen Med 2018, 12, e159; [DOI] [PMC free article] [PubMed] [Google Scholar]; b) Loessner D, Meinert C, Kaemmerer E, Martine LC, Yue K, Levett PA, Klein TJ, Melchels FP, Khademhosseini A, Hutmacher DW, Nat Protoc 2016, 11, 727. [DOI] [PubMed] [Google Scholar]
- [33].Simpson FC, McTiernan CD, Islam MM, Buznyk O, Lewis PN, Meek KM, Haagdorens M, Audiger C, Lesage S, Gueriot FX, Brunette I, Robert MC, Olsen D, Koivusalo L, Liszka A, Fagerholm P, Gonzalez-Andrades M, Griffith M, Commun Biol 2021, 4, 608. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [34].Jeon O, Samorezov JE, Alsberg E, Acta Biomater 2014, 10, 47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [35].Yadavalli T, Suryawanshi R, Ali M, Iqbal A, Koganti R, Ames J, Aakalu VK, Shukla D, Ocul Surf 2020, 18, 221. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [36].Jabbehdari S, Yazdanpanah G, Kanu LN, Anwar KN, Shen X, Rabiee B, Putra I, Eslani M, Rosenblatt MI, Hematti P, Djalilian AR, Transl Vis Sci Technol 2020, 9, 26. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data are available in the main text or the supplementary materials.