Abstract
Newly introduced provisional crowns and fixed dental prostheses (FDP) materials should exhibit good physical and mechanical properties necessary to serve the purpose of their fabrication. The aim of this systematic literature review and meta-analysis is to evaluate the articles comparing the physical and mechanical properties of 3D-printed provisional crown and FDP resin materials with CAD/CAM (Computer-Aided Designing/Computer-Aided Manufacturing) milled and conventional provisional resins. Indexed English literature up to April 2022 was systematically searched for articles using the following electronic databases: MEDLINE-PubMed, Web of Science (core collection), Scopus, and the Cochrane library. This systematic review was structured based on the guidelines given by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The focused PICO/PECO (Participant, Intervention/exposure, Comparison, Outcome) question was: ‘Do 3D-printed (P) provisional crowns and FDPs (I) have similar physical and mechanical properties (O) when compared to CAD/CAM milled and other conventionally fabricated ones (C)’. Out of eight hundred and ninety-six titles, which were recognized after a primary search, twenty-five articles were included in the qualitative analysis, and their quality analysis was performed using the modified CONSORT scale. Due to the heterogeneity of the studies, only twelve articles were included for quantitative analysis. Within the limitations of this study, it can be concluded that 3D-printed provisional crown and FDP resin materials have superior mechanical properties but inferior physical properties compared to CAD/CAM milled and other conventionally fabricated ones. Three-dimensionally printed provisional crowns and FDP materials can be used as an alternative to conventional and CAD/CAM milled long-term provisional materials.
Keywords: provisional dental resins, PMMA, 3D printing, CAD/CAM, provisional crowns, provisional fixed dental prosthesis, mechanical properties, physical properties, fracture strength, color stability, surface roughness, wear resistance, flexural strength, water absorption and solubility, modulus of elasticity, peak stress
1. Introduction
A well-fabricated provisional crown or fixed dental prosthesis (FDP) is vital in achieving a good-quality definitive prosthesis. A provisional crown or FDP must maintain the tooth position, protect the pulp, maintain the periodontal relationship, and establish function and aesthetics [1,2,3,4]. In clinical scenarios where provisionalization is required for longer durations (dental implant therapy or in full mouth rehabilitation cases involving extensive occlusal reconstruction), provisional restorative materials should have good physical and mechanical properties to avoid failures under prolonged functional loading [5,6,7].
Based on the composition, provisional restoration materials can be broadly divided into two types: (a) polymethylmethacrylate (PMMA) or polyethyl methacrylate (PEMA) based and (b) bis-acrylic or dimethacrylates resins [8]. PMMA was first used as a provisional material, and with the advancements in material science, newer materials such as bis-acrylics were introduced to provide the best clinical outcomes [8,9]. These materials were used using conventional techniques, which can be direct, indirect, or a combination of both [10].
The introduction of digital technology (computer-aided designing and computer-aided manufacturing (CAD/CAM)) in the field of prosthodontics has revolutionized the methods of providing treatments to patients. The CAD/CAM milling or subtractive manufacturing technique uses pre-polymerized resin blocks milled to provide the desired shape [11,12,13,14]. Multiple studies have compared the physical and mechanical properties of CAD/CAM milled provisional resins with conventional provisional resins and found them to have superior properties [1,4,15,16]. In addition, the inherent problems of conventional PMMA-based provisional materials (high polymerization shrinkage, high residual monomer) were minimized by using subtractive manufacturing techniques [17,18,19,20,21]. A recent literature review by Batisse et al. [21] compared the CAD/CAM and conventional denture base resins and concluded that CAD/CAM denture base resins have better physical and mechanical properties than conventional denture base resins.
More recently, additive manufacturing/three-dimensional (3D) printing techniques have gained popularity. This technique fabricates the desired prosthesis by adding small parts of the material layer by layer [22,23]. The 3D printing methods include Stereolithography (SLA), Digital light processing (DLP), Selective Laser Sintering (SLS), and Fused Deposition Modelling (FDM) [24].
Compared to CAD/CAM milling, the 3D printing technique reduces the manufacturing time and causes less wastage of raw material; thus, it can be a cost-effective option for fabricating provisional crowns and FDPs [25]. Studies comparing the physical and mechanical properties of provisional 3D-printed resins (used for fabricating provisional crowns and FDPs) with conventional and CAD/CAM milled provisional resins have shown varied results [16,26,27,28,29,30,31].
There is no known systematic review that assesses the mechanical and physical properties of 3D-printed provisional resins compared to CAD/CAM milled and conventional resins. These outcomes are important, as they can help select the best materials and techniques for fabricating provisional crowns and FDPs. Thus, the aim of this systematic literature review and meta-analysis is to compare and analyze the articles comparing the physical and mechanical properties of 3D-printed provisional crown and FDP resin materials with CAD/CAM milled and conventional provisional resins. The null hypotheses framed are that there are no differences in physical and mechanical properties of 3D-printed provisional crowns and FDP resins when compared to conventional and CAD/CAM milled provisional resins.
2. Materials and Methods
This systematic review was structured based on the guidelines given by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) (Supplementary Materials) [32]. The study was pre-registered on the PROSPERO registration platform (No.: 338845).
2.1. Selection Criteria
Inclusion and exclusion criteria are listed in Table 1.
Table 1.
Inclusion Criteria | Exclusion Criteria |
---|---|
Literature in English language | Literature in a language other than English |
Human clinical studies | Animal studies |
In vitro studies | Letters to the editor, case reports, technical reports, cadaver studies, dissertations, incomplete trials, unpublished abstracts, reports, commentaries, and review papers. |
Studies comparing the physical properties of the 3D-printed provisional crowns and fixed dental prosthesis (FDP) materials with other materials and methods used for the fabrication of provisional crowns and FDP. | Studies comparing properties other than physical and mechanical properties. |
Studies comparing mechanical properties of 3D-printed provisional crowns and FPD materials with other materials and methods used for the fabrication of provisional crowns and FPD. | Studies discussing properties of only 3D-printed provisional materials but do not compare them with other types of provisional materials |
Studies comparing accuracy, marginal, and internal adaptation of 3D-printed provisional materials with other types of provisional materials. | |
Studies discussing effects of various 3D-printing parameters (printing orientation, resin color setting, layer thickness, degree of conversion, etc.) on mechanical properties and accuracy of 3D-printed crown and bridge provisional restorative material. | |
Studies discussing materials under trial |
2.2. Exposure and Outcome
The focused PICO/PECO (Participant, Intervention/exposure, Comparison, Outcome) question was: ‘Do 3D-printed (I) provisional crowns and FDPs (P) have similar physical and/or mechanical properties (O) when compared to CAD/CAM milled and other conventionally fabricated ones (C)’:
P—Provisional Crowns and Fixed Dental Prosthesis;
I—3D-Printed Technique;
C—CAD/CAM or Conventional Technique;
O—Physical/Mechanical Properties.
2.3. Information Sources and Search Strategy
Two independent authors (S.J. and M.S.) systematically searched the indexed English literature using the following electronic databases: MEDLINE-PubMed, Web of Science (core collection), Scopus, and the Cochrane library. The search for the articles was performed in February 2022, and then it was updated in April 2022. Combinations of Medical subject heading terms (MeSH) and Non-MeSH terms along with Boolean operators were used to perform the search. Details of search strings used for the systematic search are mentioned in Table 2. Reference lists of the relevant articles were screened manually for supplementary pertinent articles which were not detected during the electronic search. The search strategy was modified according to the requirements of the database searched.
Table 2.
Database | Combination of Search Terms and Strategy | Number of Titles |
---|---|---|
MEDLINE-PubMed | ((“dental restoration, temporary”[MeSH Terms] OR “Tooth Crown”[MeSH Terms] OR “Dental Prosthesis”[MeSH Terms] OR “crowns”[MeSH Terms] OR “denture, partial, fixed”[MeSH Terms] OR “denture, partial, temporary”[MeSH Terms] OR “dental prosthesis, implant supported”[MeSH Terms] OR “Crown and Bridge materials”[Title/Abstract] OR “provisional dental restoration”[Title/Abstract] OR “provisional crown”[Title/Abstract] OR “provisional fixed partial denture”[Title/Abstract] OR “provisional resin”[Title/Abstract] OR “Provisional dental materials”[Title/Abstract] OR “provisional restorations”[Title/Abstract] OR “interim restoration”[Title/Abstract] OR “interim crown”[Title/Abstract] OR “interim resin”[Title/Abstract] OR “interim fixed partial denture”[Title/Abstract] OR “Temporary Crown and Bridge”[Title/Abstract] OR “temporary crown”[Title/Abstract] OR “Temporary dental restoration”[Title/Abstract]) AND “english”[Language] AND ((“printing, three dimensional”[MeSH Terms] OR “Stereolithography”[MeSH Terms] OR “3d print *”[Title/Abstract] OR “3d print*”[Title/Abstract] OR “Rapid prototyping”[Title/Abstract] OR “additive manufactur *”[Title/Abstract]) AND “english”[Language]) AND ((“Computer-Aided Design”[MeSH Terms] OR “polymethyl methacrylate”[MeSH Terms] OR “bisphenol a-glycidyl methacrylate”[MeSH Terms] OR “computer-aided manufacturing”[Title/Abstract] OR “Computer-Assisted Designing”[Title/Abstract] OR “Computer-Assisted manufacturing”[Title/Abstract] OR “Computer-Assisted Milling”[Title/Abstract] OR “cad cam”[Title/Abstract] OR “cad cam”[Title/Abstract] OR “Subtractive manufacturing”[Title/Abstract] OR “PEMA”[Title/Abstract] OR “bis-acryl”[Title/Abstract] OR “interim resin”[Title/Abstract] OR “provisional resin”[Title/Abstract] OR “Bis-GMA”[Title/Abstract] OR “methacrylate polymethyl”[Title/Abstract] OR “poly methyl methacrylate”[Title/Abstract] OR “PMMA”[Title/Abstract] OR “Polymethylmethacrylate”[Title/Abstract]) AND “english”[Language]) AND ((“Physical Phenomena”[MeSH Terms] OR “mechanical phenomena”[MeSH Terms] OR “stress, mechanical”[MeSH Terms] OR “Mechanical Tests”[MeSH Terms] OR “Flexural Strength”[MeSH Terms] OR “elasticity”[MeSH Terms] OR “elastic modulus”[MeSH Terms] OR “compressive strength”[MeSH Terms] OR “Tensile Strength”[MeSH Terms] OR “Shear strength”[MeSH Terms] OR “hardness”[MeSH Terms] OR “Hardness Tests”[MeSH Terms] OR “Dental Restoration Wear”[MeSH Terms] OR “solubility”[MeSH Terms] OR “color”[MeSH Terms] OR “Optical Phenomena”[MeSH Terms] OR “viscosity”[MeSH Terms] OR “Physical properties”[Title/Abstract] OR “Physical processes”[Title/Abstract] OR “Mechanical properties”[Title/Abstract] OR “Mechanical processes”[Title/Abstract] OR “fracture strength”[Title/Abstract] OR “Fracture resistance”[Title/Abstract] OR “fracture toughness”[Title/Abstract] OR “fracture load”[Title/Abstract] OR “Flexural Strength”[Title/Abstract] OR “Biaxial flexural strength”[Title/Abstract] OR “Yield strength”[Title/Abstract] OR “Fatigue strength”[Title/Abstract] OR “fatigue test”[Title/Abstract] OR “peak stress”[Title/Abstract] OR “Ultimate Tensile Strength Test”[Title/Abstract] OR “Shear Bond Strength”[Title/Abstract] OR “Elastic strength”[Title/Abstract] OR “Microhardness”[Title/Abstract] OR “wear resistance”[Title/Abstract] OR “surface wear”[Title/Abstract] OR “surface roughness”[Title/Abstract] OR “Texture analysis”[Title/Abstract] OR “water sorption”[Title/Abstract] OR “color tone”[Title/Abstract] OR “color masking”[Title/Abstract] OR “Translucency”[Title/Abstract] OR “Optical properties”[Title/Abstract] OR “Color Stability”[Title/Abstract] OR “Translucency”[Title/Abstract] OR “Color Change”[Title/Abstract] OR (“tarnish”[All Fields] OR “tarnishes”[All Fields] OR “tarnishing”[All Fields]) OR “corrosion”[Title/Abstract] OR “Creep”[Title/Abstract] OR “flow”[Title/Abstract] OR “Abrasion”[Title/Abstract] OR “Abrasion resistance”[Title/Abstract] OR “Brittleness”[Title/Abstract] OR “Toughness”[Title/Abstract] OR “Flexibility”[Title/Abstract]) AND “english”[Language])) AND (english[Filter]) | 132 |
Scopus | (“dental restoration, temporary” OR “Tooth Crown” OR “Dental Prosthesis” OR “crowns” OR “denture, partial, fixed” OR “denture, partial, temporary” OR “dental prosthesis, implant supported” OR “Crown and Bridge materials” OR “provisional dental restoration” OR “provisional crown” OR “provisional fixed partial denture” OR “provisional resin” OR “Provisional dental materials” OR “provisional restorations” OR “interim restoration” OR “interim crown” OR “interim resin” OR “interim fixed partial denture” OR “Temporary Crown and Bridge” OR “temporary crown” OR “Temporary dental restoration”) AND (“printing, three dimensional” OR “Stereolithography” OR “3d print *” OR “3d print *” OR “Rapid prototyping” OR “additive manufactur *”) AND (“Computer-Aided Design” OR “polymethyl methacrylate” OR “bisphenol a-glycidyl methacrylate” OR “computer-aided manufacturing” OR “Computer-Assisted Designing” OR “Computer-Assisted manufacturing” OR “Computer-Assisted Milling” OR “cad cam” OR “cad cam” OR “Subtractive manufacturing” OR “PEMA” OR “bis-acryl” OR “interim resin” OR “provisional resin” OR “Bis-GMA” OR “methacrylate polymethyl” OR “poly methyl methacrylate” OR “PMMA” OR “Polymethylmethacrylate”) AND (“Physical Phenomena” OR “mechanical phenomena” OR “stress, mechanical” OR “Mechanical Tests” OR “Flexural Strength” OR “elasticity” OR “elastic modulus” OR “compressive strength” OR “Tensile Strength” OR “Shear strength” OR “hardness” OR “Hardness Tests” OR “Dental Restoration Wear” OR “solubility” OR “color” OR “Optical Phenomena” OR “viscosity” OR “Physical properties” OR “Physical processes” OR “Mechanical properties” OR “Mechanical processes” OR “fracture strength” OR “Fracture resistance” OR “fracture toughness” OR “fracture load” OR “Flexural Strength” OR “Biaxial flexural strength” OR “Yield strength” OR “Fatigue strength” OR “fatigue test” OR “peak stress” OR “Ultimate Tensile Strength Test” OR “Shear Bond Strength” OR “Elastic strength” OR “Microhardness” OR “wear resistance” OR “surface wear” OR “surface roughness” OR “Texture analysis” OR “water sorption” OR “color tone” OR “color masking” OR “Translucency” OR “Optical properties” OR “Color Stability” OR “Translucency” OR “Color Change” OR tarnish * OR “corrosion” OR creep OR flow OR abrasion OR “Abrasion resistance” OR brittleness OR toughness OR flexibility) AND (LIMIT-TO (DOCTYPE, “ar”) OR LIMIT-TO (DOCTYPE, “cp”)) AND (LIMIT-TO (SUBJAREA, “DENT”)) AND (LIMIT-TO (LANGUAGE, “English”)) AND (LIMIT-TO (SRCTYPE, “j”) OR LIMIT-TO (SRCTYPE, “p”)) | 642 |
Web of Sciences (Core collection) | #1 (P) (TS = (“dental restoration, temporary” OR “Tooth Crown” OR “Dental Prosthesis” OR “crowns” OR “denture, partial, fixed” OR “denture, partial, temporary” OR “dental prosthesis, implant supported” OR “Crown and Bridge materials” OR “provisional dental restoration” OR “provisional crown” OR “provisional fixed partial denture” OR “provisional resin” OR “Provisional dental materials” OR “provisional restorations” OR “interim restoration” OR “interim crown” OR “interim resin” OR “interim fixed partial denture” OR “Temporary Crown and Bridge” OR “temporary crown” OR “Temporary dental restoration”)) AND LANGUAGE: (English) Indexes=SCI-EXPANDED, SSCI, A&HCI, CPCI-S, CPCI-SSH, ESCI, CCR-EXPANDED, IC Timespan = All years #2 (I) (TS = (“printing, three dimensional” OR “Stereolithography” OR “3d print *” OR “3d print *” OR “Rapid prototyping” OR “additive manufactur *”)) AND LANGUAGE: (English) Indexes=SCI-EXPANDED, SSCI, A&HCI, CPCI-S, CPCI-SSH, ESCI, CCR-EXPANDED, IC Timespan = All years #3 (C) (TS = (“Computer-Aided Design” OR “polymethyl methacrylate” OR “bisphenol a-glycidyl methacrylate” OR “computer-aided manufacturing” OR “Computer-Assisted Designing” OR “Computer-Assisted manufacturing” OR “Computer-Assisted Milling” OR “cad cam” OR “cad cam” OR “Subtractive manufacturing” OR “PEMA”OR “bis-acryl” OR “interim resin” OR “provisional resin”OR “Bis-GMA” OR “methacrylate polymethyl” OR “poly methyl methacrylate” OR “PMMA” OR “Polymethylmethacrylate”)) AND LANGUAGE: (English) Indexes = SCI-EXPANDED, SSCI, A&HCI, CPCI-S, CPCI-SSH, ESCI, CCR-EXPANDED, IC Timespan = All years #4 (O) (TS = (“Physical Phenomena” OR “mechanical phenomena” OR “stress, mechanical” OR “Mechanical Tests” OR “Flexural Strength” OR “elasticity” OR “elastic modulus” OR “compressive strength” OR “Tensile Strength” OR “Shear strength” OR “hardness” OR “Hardness Tests” OR “Dental Restoration Wear” OR “solubility” OR “color” OR “Optical Phenomena” OR “viscosity” OR “Physical properties” OR “Physical processes” OR “Mechanical properties” OR “Mechanical processes” OR “fracture strength” OR “Fracture resistance” OR “fracture toughness” OR “fracture load” OR “Flexural Strength” OR “Biaxial flexural strength” OR “Yield strength” OR “Fatigue strength” OR “fatigue test” OR “peak stress” OR “Ultimate Tensile Strength Test” OR “Shear Bond Strength” OR “Elastic strength” OR “Microhardness” OR “wear resistance” OR “surface wear” OR “surface roughness” OR “Texture analysis” OR “water sorption” OR “color tone” OR “color masking” OR “Translucency” OR “Optical properties” OR “Color Stability” OR “Translucency” OR “Color Change” OR tarnish* OR “corrosion” OR Creep OR flow OR Abrasion OR “Abrasion resistance” OR Brittleness OR Toughness OR Flexibility)) AND LANGUAGE: (English) Indexes = SCI-EXPANDED, SSCI, A&HCI, CPCI-S, CPCI-SSH, ESCI, CCR-EXPANDED, IC Timespan = All years #4 AND #3 AND #2 AND #1 Indexes = SCI-EXPANDED, SSCI, A&HCI, CPCI-S, CPCI-SSH, ESCI, CCR-EXPANDED, IC Timespan = All years and English (Languages) |
33 |
Cochrane Library |
|
89 |
*: Truncation, P: Population, I: Intervention, C: Comparator, O: Outcome.
2.4. Study Selection and Data Extraction
Duplicate articles were removed. The titles and abstracts of the identified articles were screened based on the pre-set inclusion and exclusion criteria (by S.G.G. and M.E.S.). Later, S.J. and M.S. cross-checked the shortlisted articles after reviewing the full texts, and disagreements related to conflicting articles were resolved after a discussion between the four authors (S.J., M.S., M.E.S., S.G.G.). S.J., M.S., M.E.S., A.A.A.O., and S.M.A. used self-designed tables to tabulate the relevant data. The information extracted was divided into two categories; Table 3 was a common table for all the selected articles giving information about the author’s name, year of publication, study type, studied characteristic and property, sample size, trade name and main composition of the evaluated materials, specimen fabrication technique, shape and dimensions of the tested samples, and layer thickness and orientation of the 3D-printing. Quality analysis results of the included studies are listed in Table 4. Moreover, Table 5, Table 6, Table 7, Table 8, Table 9, Table 10, Table 11, Table 12, Table 13, Table 14 and Table 15 gave comprehensive information about each physical or mechanical property tested. Details in these tables were related to the exposure agent/aging technique, testing machine, results of the property tested for each type of material, and authors’ conclusions and suggestions.
Table 3.
Author and Year | Study Type | Studied Characteristics |
Studied Property | Sample Size (n) | Trade Name and Manufacturer of the Evaluated Materials | Main Chemical Composition | Specimen Fabrication Technique | Shape and Dimension of Tested Resins Samples | Layer Thickness and Orientation of Printing |
---|---|---|---|---|---|---|---|---|---|
Digholkar et al., 2016 [36] |
In vitro | Flexural strength Microhardness |
MP |
n = 60 (20 per group) |
(A) Heat-activated PMMA (N/M) (B) Ceramill TEMP (AmannGirrbach) (C) E-Dent 100 (Envisiontec GmbH) |
(A) Heat cure PMMA (B) PMMA (C) Tetrahydrofurfuryl methacrylate |
(A) Conventional (B) CAD/CAM Milled (C) 3D-Printed |
Bars (25 mm × 2 mm × 2 mm) | layer thickness: N/M Orientation: N/M |
Tahayeri et al., 2018 [37] | In Vitro | Elastic modulus Peak stress |
MP | N/M | (A) Jet (Lang Dental In(C) (B) Integrity (Dentsply) (C) NextDent C&B resin (NextDent) |
(A) PMMA (B) Bisacrylic (C) Methacrylic oligomers |
(A) and (B) Conventional self-cure (C) 3D-printed |
Bars (25 × 2 × 2 mm) | layer thickness: 100 μm Orientation: 90° |
Park et al., 2018 [26] | In vitro | Wear resistance | MP |
n = 60 (20 per group) |
(A) Jet (Lang Dental Mfg. Co.) (B) Vipiblock PMMA Monocolor (VIPI) (C) C&B NextDent (NextDent) (PMM(A) |
(A) PMMA (B) PMMA (C) PMMA |
(A) conventional self-care (B) CAD/CAM milled (C) 3D printing |
Rectangular parallelepipeds (15 × 10 × 10 mm) |
layer thickness: 100 μm Orientation: 0° |
Kessler et al., 2019 [27] | In Vitro | Three-body wear | MP |
n = 40 (8 per group) |
(A) TetricEvoCeram (Vivadent) (B) Telio CAD (Ivoclar) (C) 3Delta temp (Deltame(D) (D) Nextdent C&B (NextDent) (E) Freeprint temp (Detax) |
(A) Bis-GMA (B) PMMA (C) Methacrylate (D) Methacrylic oligomers (E) Methacrylate-based resins |
(A) Conventional (B) CAD/CAM Milling (C), (D), and (E) 3D-printing |
Wheel-shaped | layer thickness: N/M Orientation: N/M |
Reeponmaha et al., 2020 [16] | In vitro | Fracture Strength | MP |
n = 40 (10 per group) |
(A) Unifast Trad (GC chemicals) (B) Protemp 4 (3 M ESP(E) (C) Brylic Solid (Sagemax bioceramics) (D) Freeprint Temp (Detax GmbH) |
(A) Methylmethacrylate resin (B) Bis-acryl resin (C) Highly polymerized PMMA resin (D) Photopolymerized Methacrylate-based resins |
((A) and ((B): Conventional (C) CAD/CAM Milling (D) 3D-printing |
Provisional crowns cemented on prepared epoxy die replicated from prepared tooth |
layer thickness: N/M Orientation: N/M |
Ibrahim et al., 2020 [38] | In vitro | Fracture Resistance | MP |
n = 16 (8 per group) |
(A) Telio CAD disc ( Ivoclar Vivadent) (B) NextDent C&B resin (NextDent B.V) |
(A) PMMA (B) MMA |
(A) CAD/CAM Milling (B) 3D-printing |
Provisional crowns cemented on prepared epoxy die replicated from prepared tooth | layer thickness: 50 μm Orientation: N/M |
Shin et al., 2020 [28] | In vitro | Color stability Water sorption and solubility |
PP |
n = 200 (40 per group) |
(A) Polycarbonate block (Line dental la(B) (B) Vipi block monocolor (Dental VIPI Ltd.) (C) MAZIC Duro (Vericom) (D) Nextdent C&B (Nextdent) (E) denture teeth A2 resins (Formlabs In(C) |
(A) Polycarbonate (B) PMMA (C) dispersed-filler composite (DF(C) (D) Methacrylic oligomers (E) UDMA |
(A), (B), (C): CAD/CAM Milling (D), (E) 3D-printing |
disk-shaped (10 mm diameter, 3 mm thickness) |
layer thickness: 100 μm Orientation: N/M |
Suralik et al., 2020 [39] | In vitro | Fracture Strength | MP |
n = 45 (15 per group) |
(A) Jet (Lang Dental Inc.) (B) Zirlux Temp (Henry Schein) (C) Freeprint Temp (DETAX GmbH) |
(A) PMMA (B) PMMA (C) Methacrylate-based resins |
(A) Conventional (Self-cur(E) (B) CAD/CAM Milling (C) 3D-Printing |
Provisional 3-unit fixed dental prosthesis (FDP) attached to implant abutments of the master metal typodont, with no luting agent. | layer thickness: 50 μm Orientation: 0° |
Reymus et al., 2020 [40] | In vitro | Fracture load | MP |
n = 195 (15 per group) |
(A) Luxatemp (DMG) (B) Telio CAD (Ivoclar-Vivadent) (C) Experimental (GC Europ(E) (D) NextDent C&B (NextDent) (E) Freeprint temp (Detax) F) 3Delta temp (Deltame(D) |
(A) Bis-acryl Methacrylate (B) PMMA Polymer (C) Methylmethacrylates (D) Methylmethacrylates (E) Methylmethacrylates F) Methylmethacrylates |
(A) Conventional (B) CAD/CAM milling (C), (D), (E), and (F): 3 D printing |
A full-anatomic three-unit FDP attached to a steel abutment model with no luting agent. | layer thickness: N/M Orientation: N/M Long-axis positioned either occlusal, buccal, or distal to the printer’s platform. |
Revilla-León et al., 2020 [41] | In vitro | Color dimensions | PP |
n = 420 (60 per group) |
(A) Protemp 4 (3M ESP(E) (B) Anaxdent (Anaxdent) (C) FreePrint Temp (Detax) (D) E-Dent 400 (EnvisionTE(C) (E) C&B (NextDent) (F) C&B MFH ((NextDent) (G) VeroGlaze MED620 (Stratasys) |
(A) Bis-acryl composite (B) PMMA (C) Monomer-based acrylic esters (D) Monomer based on acrylic esters (E) Methylmethacrylates F) Microfilled hybrid G) Monomer based on acrylic esters |
(A) and (B) Conventional (C), (D), (E), and (F): 3D-printed |
Discs (10 mm diameter, 2 mm thickness) | layer thickness: N/M Orientation: N/M |
Atria et al., 2020 [42] | In vitro | Color stability Surface roughness |
PP MP |
n = 40 (10 per group) |
(A) Marche (March(E) (B) Protemp (3M ESP(E) (C) Telio CAD (Ivoclar Vivadent) (D) Raydent C&B (3D-Materials) |
(A) acrylic resin (B) bis-acryl resin (C) PMMA (D) Hybrid composite Resin |
(A) and (B): Conventional (C) CAD/CAM Milled (D) 3D-Printed |
Rectangular blocks (1 mm × 1.7 mm × 0.6 and 1.3-mm thickness) |
layer thickness: 100 μm Orientation: 90° |
Park et al., 2020 [43] | In vitro | Flexural strength | MP |
n = 75 (15 per group) |
(A) Jet Tooth ShadeTM Powder (Lang Dental Co.) (B) ViPi (VIPI Co.) (C) NextDent C&B (NextDent Co.) (D) Standard (GPGR04) (Formlabs Co.) (E) PLA (ColorFabb Co.) |
(A) PMMA (B) PMMA (C) PMMA (D) PPMA (E) Polylactic acid |
(A) Conventional (B) CAD/CAM Milled (C) 3D-Print: DLP (D) 3D-print: SLA (E) 3D-print: FDP |
3-unit FDP fitted on the abutment of the metal jig without cementation |
layer thickness: (C) & (D) 25–100 um (E) 100–500 um Orientation: 30° |
Song et al., 2020 [44] | In vitro | color stability Water sorption & Solubility |
PP | For water sorption and solubility: n = 60 (10 per group) For Color stability: n = 120 (20 per group, 10 for coffee and 10 for te(A) |
(A) Alike (GC Co.) (B) Luxatemp Automix plus (DMG) (C) PMMA Disk (Yamahachi Dental Co) (D) Telio CAD (Ivoclar Vivadent) (E) VeroGlaze (Stratasys) (F) E-dent 100 (EnvisionTEC GmbH) |
(A) Polymethyl methacrylate (B) Bis-acryl methacrylate (C) Polymethyl methacrylate (D) Polymethyl methacrylate (E) Bio-compatible photopolymer (F) Multifunctional Acrylic resin |
(A) and (B) Conventional (C) and (D): CAD/CAM Milled (E) and (F): 3D-printed |
disk-shaped (15 mm diameter, 1 mm thickness) |
layer thickness: N/M Orientation: N/M |
Yao et al., 2021 [45] | In vitro | color stability | PP |
n = 80 (40 per group) |
(A) Temp Esthetic 98 (Harvest Dental Products) (B) NextDent Crown and Bridge resin (NextDent) |
(A) PMMA (B) Methylmethacrylates |
(A) CAD/CAM milling (B) 3D-Printing |
Provisional crowns cemented to the 3D-printed abutment teeth with interim luting agent |
layer thickness: N/M Orientation: N/M |
Abad-Coronel et al., 2021 [46] | In vitro | Fracture Resistance | MP |
n = 40 (20 per group) |
(A) Vipiblock Trilux: (VIPI) (B) PriZma 3D Bio Prov: (MarkertechLabs) |
(A) PMMA (B) Light-Curing Micro Hybrid Resin |
(A) CAD/CAM milling (B) 3D-Printing |
A 3-unit FDP fitted on a 3D-printed resin master typodont without any fixing agent. | layer thickness: N/M Orientation: N/M |
Myagmar et al., 2021 [47] | In vitro | Wear resistance Surface roughness |
MP |
n = 48 (16 per group, later divided into 8 per subgroup based on cycles of chewing simulation) |
(A) JetTM (Lang Dental Manufacturing) (B) Yamahachi PMMA Disk (Yamahachi Dental Manufacturing) (C) NextDent C&B (NextDent) |
(A) PMMA (B) PMMA (C) Methacrylic oligomers |
(A) Conventional (B) CAD/CAM Milled (C) 3D-Printed |
rectangular parallelepipeds (15 × 10 × 10 mm) |
layer thickness: 100 μm Orientation: 0° |
Tas¸ın et al., 2021 [48] | In vitro | color stability Surface roughness |
PP MP |
n = 320 (80 per group) Divided into 2 subgroups n = 40 (i) conventional polishing (ii) surface sealant covering each group (n = 10) immersed in 4 different solutions |
(A) Temdent Classic (Schütz-Dental) (B) Protemp 4 (3M ESP(E) (C) Duo Cad (FSM DENTAL) (D) Temporis (DWS) |
(A) PMMA (B) Bis-acryl composite resin (C) PMMA (D) Hybrid composite Resin |
(A) and (B) Conventional (C) CAD/CAM Milled (D) 3D-printed |
disk-shaped (10 mm diameter, 2 mm thickness) |
layer thickness: 100 μm Orientation: N/M |
Revilla-León et al., 2021 [49] | In vitro | Knoop hardness | MP |
n = 360 (60 per group) n = 20 per group used for testing each property |
(A) Protemp 4 (3M ESP(E) (B) Anaxdent new outline dentin (Anaxdent) (C) FreePrint temp (Detax) (D) E-Dent 400 C&B MFH (Envisionte(C) (E) NextDent C&B MFH (3D Systems) (F) Med620 VEROGlaze (Stratasys) |
(A) bis-acryl resin (B) acrylic resin (C)Methylmethacrylates (D) Monomer based on acrylic esters (E) Micro-Filled Hybrid Methacrylic oligomers (F) N/M |
(A) and (B): Conventional (C), (D), (E), and (F): 3D-Printed |
Disks (10 mm diameter, 2 mm thickness) | layer thickness: 50 μm Orientation: 90° |
Mayer et al., 2020 [50] | In vitro | Fracture load & Two-body wear |
MP |
n = 152 (48 per group for 3D-printed and 8 for CAD/CAM Mille(D) |
((A) Telio CAD disc (Ivoclar Vivadent) (B) Freeprint temp (Detax) ((C) GC Temp PRINT (GC Europe) ((D) Next dent C&B MFH (NextDent) After printing, excessive resin removed from the specimen’s surface in 3 ways: (i) Centrifugation (CEN); (ii) Chemical cleaning by Isopropanol (ISO); (iii) Chemical cleaning by Yellow Magic (YEL) |
(A) PMMA (B) Methylmethacrylates (C) UDMA (D) Methylmethacrylates |
(A) CAD/CAM milling (B), (C), and (D): 3D-Printing |
A full anatomic, three-unit FDP fixed on steel abutment model with a dual-cure self-adhesive resin composite cement |
layer thickness: N/M Orientation: N/M |
Henderson et al., 2022 [51] |
In vitro | Failure Load | MP |
n = 180 (60 per group) Storage time: 1 day and 30 days & Loading rate: 1, 10 and Combined 1 and 10 mm/min |
(A) 3M-Paradigm (3M Oral Car(E) (B) Solid Shade PMMA Disc (TD Dental Supply) (C) Dentca Crown and Bridge resin (Dentc(A) |
(A) Bis-acryl resin (B) PMMA (C) bis-acryl resin |
(A) Conventional (B) CAD/CAM milling (C) 3D-Printing |
3-unit interim FDP cemented onto 3D-printed resin dies. | layer thickness: N/M Orientation: N/M |
Martín-Ortega et al., 2022 [52] | In vitro | Fracture Resistance | MP |
n = 40 (10 per group) (10 each anterior and posterior, CAD/CAM milled and 3D-printe(D) |
(A) and (C): Vivodent CAD Multi: (Ivoclar Vivadent AG) (B) and (D): SHERAprint-cb (Sher(A) |
(A) PMMA (B) Photopolymer interim dental resin |
(A) CAD/CAM milling (B) 3D-Printing |
Full anatomic crowns (20 anterior and 20 posterior) cemented on implant abutment with autopolymerizing composite resin cement |
layer thickness: 50 μm Orientation: 45° |
Simoneti et al., 2022 [53] | In vitro study | flexural strength Vickers microhardness Elastic Modulus surface roughness before and after polishing |
MP | Interim single crowns n = 40 (10 per group) Rectangular blocks n = 40 (10 per group) disks n = 40 (10 per group) |
(A) Dencor (Artigos Odontológicos Clássico Ltd.(A) (B) Yprov Bisacryl (Yller Biomaterials) (C) PA2201 (Stratasys Direct Manufacturing) (D) Gray Resin (Formlabs In(C) |
(A) PMMA (B) Bis-acryl resin (C) PMMA (D) Oligomers methacrylates |
(A) and (B): Conventional (C) and (D) 3D-Printed SLS & SLA |
Interim single crowns rectangular blocks 4 × 2 × 10 mm disks 10 mm diameter, 2 mm thickness |
layer thickness: N/M Orientation: N/M |
Crenn et al., 2022 [29] | In vitro | 3-point bending test (elastic modulus) Flexural strength Hardness |
MP |
n = 40 (10 per group) |
(A) Integrity (Dentsply Caulk) (B) Unifast (GC, Tokyo) (C) PLA Bio source (Nanovi(A) (D) Temporary CB (Formlabs) |
(A) Bisacrylic (B) Methylmethacrylate resin (C) Polylactic acid (D) Esterification products of 4,4′-isopropylidenediphenol |
(A) and (B): Conventional (C) 3D-printed (FDM) (D) 3D-Printed (SL(A) |
Bars (25 mm × 2 mm × 2 mm) | layer thickness: FDM: 100 μm SLA: 50 μm Orientation: FDM: 0° SLA: 0° |
Tas¸ın et al., 2022 [30] | In vitro | Flexural strength Resilience Toughness Modulus of elasticity |
MP |
n =120 (30 per group, 10 each for flexural strength, resilience, and toughness) Sub group (n = 10) based on different thermocycling |
(A) Temdent Classic (Schütz-Dental) (B) Protemp 4 (3M ESP(E) (C) Duo Cad (FSMDENTAL) (D) Temporis (DWS) |
(A) MMA (B) Bis-acryl (C) PMMA (D) Composite resin |
(A) and (B): conventional (C) CAD/CAM Milled (D) 3D-printed |
Rectangular plate (25 × 2 × 2 mm) | layer thickness: 60 μm Orientation: 90° |
Pantea et al., 2022 [31] | In vitro | Flexural strength Elastic Modulus |
MP | n = 40 (10 per group, 5 each for flexural strength and compression strength) | (A) Duracyl (SpofaDental a.s) (B) Superpont C + B (SpofaDental a.s.) (C) NextDent C&B MFH (NextDent) (D) HARZ Labs Dental Sand (HARZ Labs) |
(A) Auto-polymerized (PMM(A) (B) Pressure/heat-cured (PMM(A) (C) Microfilled hybrid PMMA (D) PMMA |
(A) Conventional self-cure (B) Conventional heat cured (C) and (D): 3D-Printed |
For Flexural strength: Bar shaped (80 × 20 × 5 mm) For Compressive strength: Cylindrical shaped (25 × 25 mm) |
layer thickness: 50 μm Orientation: N/M |
MP: Mechanical Property; PP: Physical Property; FS: Fracture Strength; FR: Fracture resistance; FL: Fracture load; FaL: Failure Load; N/M: Not Mentioned; CAD/CAM: Computer-Aided Designing/Computer-Aided Manufacturing; FDP: Fixed Dental Prosthesis; SLA: Stereolithography; SLS: Selective laser sintering; FDM: Fused deposition modeling; DLP: Digital light processing; UDMA: urethane dimethacrylate.
Table 4.
Item | 1 | 2a | 2b | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Studies | |||||||||||||||
Digholkar et al., 2016 [36] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | Y | N |
Tahayeri et al., 2018 [37] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | Y | Y |
Park et al., 2018 [26] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | Y | N |
Kessler et al., 2019 [27] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N |
Reeponmaha et al., 2020 [16] | Y | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | N | Y | N |
Ibrahim et al., 2020 [38] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | N | N |
Shin et al., 2020 [28] | Y | Y | Y | Y | Y | N | Y | Y | N | N | Y | Y | Y | Y | Y |
Suralik et al., 2020 [39] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | Y |
Reymus et al., 2020 [40] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N |
Revilla-León et al., 2020 [41] | Y | Y | Y | Y | Y | Y | N | N | N | N | Y | Y | Y | N | N |
Atria et al., 2020 [42] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | N | N |
Park et al., 2020 [43] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N |
Song et al., 2020 [44] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | N | N |
Yao et al., 2021 [45] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | N | N |
Abad-Coronel et al., 2021 [46] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | Y |
Myagmar et al., 2021 [47] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N |
Taşın et al., 2021 [48] | Y | Y | Y | Y | Y | Y | N | N | N | N | Y | Y | Y | N | N |
Revilla-León et al., 2021 [49] | Y | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | Y | Y | N |
Mayer et al., 2021 [50] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | N | N |
Henderson et al., 2021 [51] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | N | N | N |
Martín-Ortega et al., 2022 [52] | Y | Y | Y | Y | Y | N | Y | N | N | N | Y | Y | Y | N | N |
Simoneti et al., 2022 [53] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N |
Crenn et al., 2022 [29] | Y | Y | Y | Y | Y | Y | N | N | N | N | Y | Y | N | Y | N |
Taşın et al., 2022 [30] | Y | Y | Y | Y | Y | Y | N | N | N | N | Y | Y | Y | N | N |
Pantea M. et al., 2022 [31] | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | Y |
Table 5.
Author and Year | Immersion Media/Surface Treatment | Immersion/Exposure Duration/Aging | Mean Change in Color of Conventional Polymerized Resin | Mean Change in Color of CAD/CAM Milled Provisional Resin | Mean Change in Color of 3D-Printed Provisional Resin | Instrument Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|---|
Yao et al., 2021 [45] | (i) Control (no surface treatment) (ii) Polishing (iii) Polishing + Optiglaze coating (iv) Polishing + Skinglaze coating |
Aging: Thermocycling: 5000 cycles at 5–50 °C (simulating 6 months of physiological aging) |
N/A | ΔE (i) 2.38 ± 0.44 (ii) 1.83 ± 0.51 (iii) 1.01 ± 0.38 (iv) 1.85 ± 0.78 |
ΔE (i) 3.83 ± 0.71 (ii) 2.66 ± 0.89 (iii) 1.37 ± 0.67 (iv) 1.40 ± 0.73 |
Digital spectrophotometer (Vita Easyshade V) |
|
Shin et al., 2020 [28] | Immersion media: (i) Grape juice (ii) Coffee (iii) Curry (iv) Distilled water |
Upto 30 days inside a 37 °C (simulating 2.5 years) | N/A | ΔE00 Between 0.64 and 4.12 |
ΔE00 Between 4.47 and 22.85 |
colorimeter (Minolta Cr321 Chromameter) |
|
Song et al., 2020 [44] | Immersion media: (i) Coffee (ii) Black tea |
Week: 1,2,4,8,12 | ΔE after week 12 (A) Alike: 9.89 ± 1.95 (coffee) 14.69 ± 3.05 (Black Tea) (B) Luxatemp Automix plus: 4.20 ± 1.57 (coffee) 6.52 ± 2.50 (Black Tea) |
ΔE after week 12 (C) PMMA Disk: 10.35 ± 1.14 (coffe(E) 16.66 ± 3.05 (Black Tea) (D) Telio CAD: 21.07 ± 2.86 (coffee) 24.60 ± 4.30 (Black Tea) |
ΔE after week 12 (E) VeroGlaze: 19.80 ± 2.85 (coffe(E) 16.90 ± 2.20 (Black Tea) (F) E-dent 100: 20.01 ± 3.00 (coffee) 22.13 ± 3.51 (Black Tea) |
spectrocolorimeter (Xrite Benchtop Spectrophotometer) |
|
Taşın et al., 2021 [48] | Surface treatment: (i) conventional polishing (ii) surface sealant—biscover LV Immersion Media: (A) distilled water (B) Cola (C) Coffee (D) Red Wine |
Days: 1, 7 & 30 | ΔE00 after 30 days PT & CAT Threshold values ## (A) Temdent Classic (i) Polished: Distilled water (1.87): > PT Cola (3.29), Coffee, Wine > CAT (ii) Surface sealant: Distilled water < PT Cola < CAT Coffee, Wine > CAT (B) Protemp 4 (i) Polished: Distilled water: > PT Cola, Coffee, Wine > CAT (ii) Surface sealant: Distilled water (1.34): < PT Cola (2.54) < CAT Coffee, Wine > CAT |
ΔE00 after 30 days (C) Duo Cad: (i) Polished: Distilled water: < PT Cola < CAT Coffee, Wine > CAT (ii) Surface sealant: Distilled water: < PT Coffee (2.15) and Cola < CAT Wine > CAT |
ΔE00 after 30 days (D) Temporis: (i) Polished: Distilled water: < PT Cola < CAT Coffee, Wine > CAT (ii) Surface sealant: Distilled water: < PT Cola < CAT Coffee, Wine > CAT |
Digital spectrophotometer (VITA Easyshade; Vita Zahnfabrik) |
|
Atria et al., 2020 [42] | N/A | Aging: Thermocycling: 6000 cycles at 5–50 °C |
PT and CAT Threshold values ## (A) Marche: 0.6 mm thickness: ΔE00 > PT 1.3 mm thickness: ΔE00 < PT (B) Protemp: 0.6 mm thickness: ΔE00 > PT 1.3 mm thickness: ΔE00 < PT |
(C) Telio CAD: 0.6 mm thickness: ΔE00 < PT 1.3 mm thickness: ΔE00 < PT |
(D) Raydent C&B: 0.6 mm thickness: ΔE00 > CAT 1.3 mm thickness: ΔE00 > CAT |
Spectrophotometer (VITA Easyshade; Vita Zahnfabrik) |
ΔE00: 3D-Printed hybrid composite > Conventional acryic and bisacrylic > CAD/CAM Milled PMMA |
N/A: Not Applicable; PT: perceptibility threshold; CAT: clinical acceptability threshold; ##: The ΔE00 evaluation is based on: PT set at ΔE00 ≤ 1.30 and the CAT set at ΔE00 ≤ 2.25 units.
Table 6.
Author and Year | Water Sorption of Conventional Cured Resin | Water Sorption of CAD/CAM Milled Resin | Water Sorption of 3D-Printed Resin | Solubility of Conventional Cured Resin | Solubility of CAD/CAM Milled Resin | Solubility of 3D-Printed Resin | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|---|
Shin et al., 2020 [28] |
N/A | (A) Polycarbonate block: 0.43% (B) Vipi block (PMMA): 1.45% (C) MAZIC Duro (DFC): ≅0.88% |
(D) Nextdent C&B: 1.04% (E) Denture teeth A2 Resin: 1.21% |
N/A | (A) Polycarbonate block: 0.12% (B) Vipi block (PMM(A) ≅0.34% (C) MAZIC Duro (DFC): = 0.07% |
(D) Nextdent C&B: 0.53% (E) Denture teeth A2 Resin: 0.47% |
Water sorption: Conventional PMMA > 3D-Printed Denture teeth A2 Resin > 3D-Printed PMMA > Conventional Polycarbonate > Conventional DFC Water Solubility: 3D-Printed PMMA > 3D-Printed Denture teeth A2 Resin > Conventional Vipi block PMMA > Conventional DFC > conventional Polycarbonate |
Song et al., 2020 [4] | (A) Alike: 32.23 ± 5.93 (B) Luxatemp Automix plus: 14.15 ± 1.30 |
(C) PMMA Disk: 23.16 ±1.25 (D) Telio CAD: 19.13 ± 1.41 |
(E) VeroGlaze: 35.02 ± 1.43 (F) E-dent 100: 20.08 ± 2.27 |
In μgm/mm3 (A) Alike: 3.54 ± 1.81 (B) Luxatemp Automix plus: 0.38 ± 0.56 |
In μgm/mm3 (C) PMMA Disk: 0.84 ± 0.61 (D) Telio CAD: 0.97 ± 0.47 |
In μgm/mm3 (E) VeroGlaze: 0.52 ± 0.80 (F) E-dent 100: 2.78 ± 1.49 |
Water sorption: Conventional PMMA > 3D-printed photopolymer > CAD/CAM Milled (PMMA Disk) > 3D-Printed acrylic > CAD/CAM milled PMMA > Conventional bis-acrylic. Water Solubility: Conventional PMMA & 3D-printed acrylic > 1 μg/mm3. For other four groups <1 μg/mm3. |
N/A: Not Applicable.
Table 7.
Author and Year | Exposure Agent/Aging Technique | Testing Machine Used | Mean Maximum Force at Fracture for Conventional Resin (N) | Mean Maximum Force at Fracture for CAD/CAM Milled Resin (N) | Mean Maximum Force at Fracture for 3D-Printed Resin (N) | Conclusions and/or Suggestions |
---|---|---|---|---|---|---|
Reeponmaha et al., 2020 [16] | (A) Thermal Cycling: 5000 cycles at 5–55 °C (B) Cyclic occlusal load: 100 N at 4 Hz for 100,000 cycles |
Universal testing machine | (A) Unifast Trad: 657.87 ± 82.84 (B) Protemp 4: 1125.94 ± 168.07 |
(C) Brylic Solid: 953.60 ± 58.88 | (D) Freeprint Temp: 1004.19 ± 122.18 |
|
Ibrahim et al., 2020 [38] | (A) Thermocycling: 1250 cycles at 5–55 °C (B) Mechanical aging: 50 N, 37,500 cycles |
Universal testing machine | N/A | (A) TelioCAD: 933.46 ± 104.49 |
(B) Next dent C&B resin: 1226.48 ± 48.33 |
|
Suralik et al., 2020 [39] | N/M | Universal Instron machine | (A) Jet:300.61 ± 98.94 | (B) Zirlux Temp: 294.64 ± 60.34 | (C) Freeprint Temp: 408.49 ± 132.16 |
|
Reymus et al., 2020 [40] | Artificial aging: stored in distilled water for 21 days at 37 °C in an incubator. | Universal testing machine | (A) Luxatemp: 551.7 ± 130 |
(B) Telio CAD: 881.4 ± 239.2 | Depending on type of post-curing unit used: [Otoflash (OF), Printbox (PB), Labolight (LL)] (C) Experimental: LL: 585.4 ± 66.8, OF: 746.4 ± 62.1, PB: 874.3 ± 104.0 (D) NextDent C&B LL: 775.9 ± 57.6, OF: 1050.4 ± 133.3, PB: 871.5 ± 398.1 (E) Freeprint temp LL: 777.6 ± 95.9, OF: 638.0 ± 175.5, PB: 598.6 ± 170.1 (F) 3Delta temp LL: 609.6 ± 118.8, OF: 868.2 ± 139.8, PB: 678.4 ± 193.7 |
|
Mayer et al., 2020 [50] | Three different cleaning methods for 3D printed specimens and chewing simulation (vertical load of 50 N and a lateral movement of 0.7 mm for 480,000 masticatory cycles) |
Universal testing machine | N/A | (A) Telio CAD: 1427 ± 77 | (B) Freeprint temp: 623 ± 156, 539 ± 152 & 615 ± 124 ((C) GC Temp PRINT: 878 ± 139, 796 ± 121, 831 ± 260 ((D) Next dent C&B MFH: 750 ± 156, 660 ± 198, 813 ± 157 |
|
Abad-Coronel et al., 2021 [46] | Thermocycling: 5000 cycles, at 5 °C and 55 °C in distilled water | Universal testing machine | N/A | (A) Vipiblock Trilux: 1663.57 ± 130.25 | PriZma 3D Bio Prov: 1437.74 ± 73.41 | FS: CAD/CAM Milled PMMA > 3D-Printed micro-hybrid resins |
Martín-Ortega et al., 2022 [52] | Thermocycling: 525,000 cycles, at 5 °C to 55 °C |
Universal testing machine | N/A | (A) and (C): Vivodent CAD Multi: Anterior group: 988.4 ± 54.8 Posterior group: 423.8 ± 68.0 |
(B) and (D): SHERAprint-cb: Anterior group: 636.5 ± 277.1 Posterior group: 321.3 ± 128.6 N |
FR: CAD/CAM Milled PMMA > 3D-Printed photopolymer resinFR: Anterior group > Posterior group |
Henderson et al., 2022 [51] |
Storage time in incubator (1 day or 30 days). | Universal testing machine | 3M-Paradigm: Loading Rate -Combined 1 and 10 mm/min Storage time: 1 day: 537 ± 117 N 30 Days: 572 ± 139 N |
Solid Shade PMMA Disc: Loading Rate -Combined 1 and 10 mm/Min Storage time: 1 day: 683 ± 115 N 30 Days: 547 ± 92 N |
Dentca Crown and Bridge resin: Loading Rate—Combined 1 and 10 mm/Min Storage time: 1 day: 522 ± 98 N 30 Days: 416 ± 109 N |
FaL: CAD/CAM Milled > Conventional > 3D-Printed |
N: Newton; N/A: Not Applicable; N/M: Not Mentioned; FS: Fracture Strength; FR: Fracture resistance; FL: Fracture load; FaL: Failure Load.
Table 8.
Author and Year | Mean Microhardness for Conventional Resin (Kgf/mm2/KHN) | Mean Microhardness for CAD/CAM Milled Resin (Kgf/mm2/KHN) | Mean Microhardness for 3D-Printed Resin (Kgf/mm2/KHN) | Surface Treatment/Exposure Agent/Ageing Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Simoneti et al., 2022 [53] |
Vickers microhardness (A) Acrylic resin: 14.2 ± 2.6 Kgf/mm2 (B) Bis-acryl resin: 10.7 ± 2.2 Kgf/mm2 |
NA | Vickers microhardness (C) SLA resin 8.4 ± 0.2 Kgf/mm2 (D) SLS resin 10.3 ± 1.0 Kgf/mm2 |
Polished specimens | Microdurometer (FM-700; Future-Tech Corp.). |
Microhardness: Conventional Acrylics > Conventional Bisacrylic > 3D-printed PMMA > 3D-printed methacrylates |
Revilla-León et al., 2021 [49] | Knoop hardness (A) Protemp 4: 4.92 ± 0.36 KHN (B) Anaxdent new outline dentin: 13.35 ± 5.84 |
N/A | Knoop hardness (C) FreePrint temp: 12.55 ± 2.93 KHN(D) E-Dent 400 C&B MFH: 13.03 ± 3.29 KHN (E) NextDent C&B MFH: 9.91 ± 3.71 (F) Med620 VEROGlaze: 13.45 ± 2.93 |
N/M | Microhardness tester (MMT-X7, Matsuzawa) |
|
Digholkar et al., 2016 [33] | Knoop hardness (A) heat activated PMMA: 27.36 ± 0.535 KHN |
Knoop hardness (B) Ceramill TEMP: 25.33 ± 0.900 KHN |
Knoop hardness (C) E-Dent 100: 32.77 ± 1.361 KHN |
N/M | Microhardness tester (Reichert Austria) |
3D-printed Microhybrid filled composite >Conventional heat activated PMMA >CAD/CAM milled PMMA |
Crenn et al., 2022 [29] | Vickers Microhardness (A) Integrity: 27.3 ± 1.8 HV (B) Unifast: 18.4 ± 1.2 HV |
N/A | Vickers Microhardness (C) PLA Bio source: 17.5 ± 0.7 HV (D) Temporary CB: 28.9 ± 2.9 HV |
Polished specimens | Vickers Microhardness tester (MH3, Mekton, Turkey) |
3D-printed SLA > Conventional Bisacrylic > conventional Methylmethacrylate > 3D-Printed FDM |
N/A: Not Applicable; SLA, stereo lithography; SLS, selective laser sintering; N/M: Not Mentioned.
Table 9.
Author and Year | SR of Conventional Material Before Surface Treatment (Ra in μm) | SR of Conventional Material After Surface Treatment (Ra in μm) | SR of CAD/CAM Milled Materials Before Surface Treatment (Ra in μm) | SR of CAD/CAM Milled Materials after Surface Treatment (Ra in μm) | SR of 3D-Printed Materials before Surface Treatment (Ra in μm) | SR of 3D-Printed Materials after Surface Treatment (Ra in μm) | Parameters of the Clinical Simulation | Exposure Medium Causing Change in SR | Measuring Device | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|---|---|---|---|
Simoneti et al., 2022 [53] | Before polishing (A) Dencor (PMMA): 4.8 ± 0.6 (B) Yprov Bisacryl (Bis-acryl resin) 1.5 ± 0.3 |
After polishing (A) Dencor (PMMA): 0.9 ± 0.2 (B) Yprov Bisacryl (Bis-acryl resin) 0.7 ± 0.1 |
N/A | N/A | Before polishing (C) PA2201 (SLS resin) 6.2 ± 0.6 (D) Gray Resin (SLA resin) 1.5 ± 0.4 |
After polishing (C) PA2201 (SLS resin) 1.2 ± 0.3 (D) Gray Resin (SLA resin) 0.7 ± 0.1 |
Polishing | N/A | Contact profiler (SJ-201; MitutoyoInc) |
Ra after polishing: 3D-Printed SLS > conventional PMMA > Conventional bisacrylic = 3D printed SLA Significant reduction in SR after polishing. |
Tas¸ın et al., 2021 [48] | Polishing (A) Temdent Classic (PMMA): 0.52 ± 0.09 (B) Protemp 4 (Bis-acrylic): 0.31 ± 0.04 |
Polishing + Surface Sealant (A) Temdent Classic (PMMA): 0.43 ± 0.07 (B) Protemp 4 (Bis-acrylic): 0.29 ± 0.05 |
Polishing (C) Duo Cad (PMMA): 0.35 ± 0.07 |
Polishing + Surface Sealant (C) Duo Cad (PMMA): 0.32 ± 0.06 |
Polishing (D) Temporis (Hybrid composite): 0.23 ± 0.04 |
Polishing + Surface Sealant (D) Temporis (Hybrid composite): 0.23 ± 0.03 |
Polishing and surface sealant | N/A | Contact profilometer (MarSurf PS10; Mahr GmbH) |
Ra after polishing only: Conventional PMMA > CAD/CAM Milled PMMA > Conventional Bisacrylic > 3D-Printed hybrid composite Significant reduction in SR after application of surface sealant for all groups except in 3D-printed materials. |
Atria et al., 2020 [42] | Ra before: (A) Marche (1.3 mm): 0.22 ± 0.01 Marche (0.6 mm): 0.26 ± 0.02 (B) Protemp (1.3 mm): 0.18 ± 0.01 Portemp (0.6 mm): 0.20 ± 0.02 Ra after Thermocycling: (A) Marche (1.3 mm): 0.31 ± 0.02 Marche (0.6 mm): 0.31 ± 0.02 (B) Protemp (1.3 mm): 0.23 ± 0.01 Portemp (0.6 mm): 0.25 ± 0.02 Δ Ra (A) Marche (1.3 mm): 0.09 ± 0.02 Marche (0.6 mm): 0.05 ± 0.02 (B) Protemp (1.3 mm): 0.05 ± 0.02 Portemp (0.6 mm): 0.04 ± 0.02 |
Ra before: (C) TelioCAD (1.3 mm): 0.20 ± 0.02 TelioCAD (0.6 mm): 0.20 ± 0.02 Ra after Thermocycling: (C) TelioCAD (1.3 mm): 0.19 ± 0.01 TelioCAD (0.6 mm): 0.20 ± 0.01 Δ Ra (C) TelioCAD (1.3 mm): −0.01 ± 0.02 TelioCAD (0.6 mm): 0.00 ± 0.01 |
Ra before: (C) Raydent (1.3 mm): 0.26 ± 0.03 Raydent (0.6 mm): 0.21 ± 0.02 Ra after Thermocycling: (C) Raydent (1.3 mm): 0.54 ± 0.03 Raydent (0.6 mm): 0.60 ± 0.03 Δ Ra (C) Raydent (1.3 mm): 0.28 ± 0.02 Raydent (0.6 mm): 0.38 ± 0.03 |
Polishing | Thermocycling: 6000 cycles at 5–55 °C |
Rugosimeter (SRT 1200; PCE instruments) | Δ Ra: 3D-Printed hybrid composite > Conventional PMMA > Conventional Bis-acryl resin > CAD/CAM PMMA. |
|||
Myagmar et al., 2021 [47] | Ra Before Wear test 0.26 ± 0.02 |
After wear test (A) 30,000 cycles: 0.92 ± 0.09 (B) 60,000 cycles: 1.63 ± 0.44 |
Before Wear test 0.19 ± 0.03 |
After wear test (A) 30,000 cycles: 0.88 ± 0.05 (B) 60,000 cycles: 1.27 ± 0.49 |
Before Wear test 0.13 ± 0.01 |
After wear test (A) 30,000 cycles: 0.48 ± 0.06 (B) 60,000 cycles: 0.58 ± 0.06 |
Polishing | Simulated chewing subjected to 30,000 or 60,000 cycles of chewing simulation against the metal abrader | Confocal laser scanning microscope (LSM 800 MAT, Zeiss) | Ra after wearing: Conventional PMMA > CAD/CAM Milled PMMA > 3D-Printed PMMA |
Table 10.
Author and Year | Mean/Medians and Interquartile Ranges (IQRs) of the Volume Loss (mm3) for Conventional | Mean/Medians and Interquartile Ranges (IQRs) of the Volume Loss (mm3) for CAD/CAM Milled | Mean/Medians and Interquartile Ranges (IQRs) of the Volume Loss (mm3) for 3D-Printed | Mean/Medians and IQRs of the Maximal Depth Loss (mm) for Conventional | Mean/Medians and IQRs of the Maximal Depth Loss (mm) for CAD/CAM Milled | Mean/Medians and IQRs of the Maximal Depth Loss (mm) for 3D-Printed | Parameters of the Chewing Simulator | Measuring Device | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|---|---|---|
Park et al., 2018 [26] | Median and IQR Jet (PMMA) Against Zirconia abrader: 1.06 (0.93–1.63) Against metal abrader: 1.06 (0.73–2.30) |
Median and IQR Vipiblock (PMMA) Against Zirconia abrader: 1.20 (0.90–1.42) Against metal abrader: 1.11 (0.63–1.81) |
Median and IQR C&B (PMMA) Against Zirconia abrader: 1.11 (0.96–1.50) Against metal abrader: 1.22 (0.47–2.20) |
Median and IQR Jet (PMMA) Against Zirconia abrader: 0.35 (0.32–0.41) Against metal abrader: 0.38 (0.25–0.57) |
Median and IQR Vipiblock (PMMA) Against Zirconia abrader: 0.35 (0.30–0.41) Against metal abrader: 0.38 (0.28–0.51) |
Median & IQR C&B (PMMA) Against Zirconia abrader: 0.36 (0.32–0.43) Against metal abrader: 0.42 (0.22–0.56) |
|
3-axis blue LED light scanner (Identica Hybrid) |
Wear resistance of the 3D-printed PMMA resin material is comparable to CAD/CAM milled PMMA or the conventionally fabricated PMMA resin materials. 3D-printed resins provide adequate wear resistance for dental use. |
Mayer et al., 2020 [50] | N/A | Mean ± SD Against metal abrader: (A) Telio CAD −0.421 ± 0.216 |
Mean ± SD Against metal abrader: (B) Freeprint temp CEN: −0.168 ± 0.078 ISO: −0.137 ± 0.064 YEL: −0.134 ± 0.052 (C) GC Temp PRINT CEN: −0.193 ± 0.075 ISO: −0.283 ± 0.13 YEL: −0.236 ± 0.037 (D) Next dent C&B MFH CEN: −0.246 ± 0.072 ISO: −0.142 ± 0.028 YEL: −0.15 ± 0.065 |
N/A | Mean ± SD Against metal abrader: (A) Telio CAD disc −0.181 ± 0.071 |
Mean ± SD Against metal abrader: (B) Freeprint temp CEN: −0.115 ± 0.026 ISO: −0.100 ± 0.024 YEL: −0.107 ± 0.023 (C) GC Temp PRINT CEN: −0.145 ± 0.027 ISO: −0.147 ± 0.034 YEL: −0.154 ± 0.032 (D) Next dent C&B MFH CEN: −0.148 ± 0.025 ISO: −0.104 ± 0.027 YEL: −0.131 ± 0.031 |
|
laser scanner (LAS-20; SD) | Two body Wear resistance: 3D-Printed PMMA > CAD/CAM Milled PMMA No significant effect of cleaning method on wear resistance of 3D-printed materials. |
Myagmar et al., 2021 [47] | Mean ± SD (A) JetTM After 30,000 cycles: 0.11 ± 0.01 After 60,000 cycles: 0.44 ± 0.01 |
Mean ± SD (B) Yamahachi PMMA After 30,000 cycles: 0.06 ± 0.01 After 60,000 cycles: 0.21 ± 0.02 |
Mean ± SD (C) NextDent C&B After 30,000 cycles: 0.08 ± 0.09 After 60,000 cycles: 0.10 ± 0.01 |
N/A | N/A | N/A |
|
multiline blue LED light scanner (D1000, 3Shape) |
wear resistance: 3D-Printed PMMA > CAD/CAM milled PMMA > conventional PMMA |
Kessler et al., 2019 [27] | N/A | N/A | N/A | Mean Wear loss in μm (A) TetricEvoCeram: Average Mean Wear loss: 50 ± 15 μm Mean Wear loss (i) 50,000 cycles: 13 ± 5 (ii) 100,000 cycles: 23 ± 2.3 (iii) 150,000 cycles: 35 ± 9 (iv) 200,000 cycles: 50 ± 15 |
Mean Wear loss in μm (B) Telio CAD Average Mean Wear loss: <236 ± 31 μm Mean Wear loss (i) 50,000 cycles: 56 ± 5 (ii) 100,000 cycles: 111 ± 210 (iii) 150,000 cycles: 178 ± 10 (iv) 200,000 cycles: 236 ± 31 |
Mean Wear loss in μm (C) 3Delta temp Average Mean Wear loss: <62 ± 4 μm Mean Wear loss: (i) 50,000 cycles: 16 ± 2 (ii) 100,000 cycles: 32 ± 1.4 (iii) 150,000 cycles: 48 ± 3 (iv) 200,000 cycles: 62 ± 4 (D) Nextdent C&B Average Mean Wear loss: < 255 ± 13 μm Mean Wear loss: (i) 50,000 cycles: 66 ± 5 (ii) 100,000 cycles: 134 ± 4.6 (iii) 150,000 cycles: 200 ± 7 (iv) 200,000 cycles: 255 ± 13 (E) Freeprint temp Average Mean Wear loss:< 257 ± 24 μm Mean Wear loss (i) 50,000 cycles: 57 ± 5 (ii) 100,000 cycles: 125 ± 2.8 (iii) 150,000 cycles: 191 ± 6 (iv) 200,000 cycles: 257 ± 24 |
Antagonist wheel rotated 15% slower than the sample wheel and pressed against it with a spring force of 15 N. | LaserScan3D, Willytec |
|
N/A: Not Applicable.
Table 11.
Author and Year | Mean/Median of Maximum Force at Fracture for Conventional Resin | Mean/Median of Maximum Force at Fracture for CAD/CAM Milled Resin | Mean/Median of Maximum for 3D-Printed Resin | Exposure Agent/Aging Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Park et al., 2020 [43] | Medians and IQRs of FS: (A) Jet Tooth ShadeTM Powder: 543 N [IQR: 429–701] |
Medians and IQRs of FS: (B) ViPi: 1232 N [IQR: 1193–1258] |
Medians and IQRs of FS: (C) NextDent C&B: 1189 N [IQR: 1110–1283] (D) Standard (GPGR04): 1323 N [IQR: 1245–1377] (E) PLA: Data N/A |
N/M | Universal testing machine | FS: 3D-printed PPMA ((D) > CAD/CAM milled PMMA > 3D-Printed PMMA ((C) > conventional PMMA The (FDM) group 3D-printed Polylactic-acid-based restoration did not fracture but was dented |
Crenn et al., 2022 [29] | Mean FS: (A) Integrity: 115.4 ± 20.5 MPa (B) Unifast: 85.79 ± 6.00 MPa |
N/A | Mean FS: (C) PLA: 115.8 ± 2.11 MPa (D) Temporary CB: 134.9 ± 17.51 MPa |
N/M | Universal testing machine | FS: 3D-Printed SLA Polymer > 3D-Printed PLA ≥ Conventional Bis-acrylic > conventional MMA |
Tas¸ın et al., 2022 [30] | Median in MPa (A) Temdent Classic Thermocycling: (i) 0 cycles: 68 (ii) 2500 cycles: 62 (iii) 10,000 cycles: 49 (B) Protemp: Thermocycling: (i) 0 cycles: 113 (ii) 2500 cycles: 108 (iii) 10,000 cycles: 99 |
Median in MPa (C) Duo Cad: Thermocycling: (i) 0 cycles: 127 (ii) 2500 cycles: 122 (iii) 10,000 cycles: 117 |
Median in MPa (D) Temporis: Thermocycling: (i) 0 cycles: 125 (ii) 2500 cycles: 125 (iii) 10,000 cycles:116 |
Thermocycling control (0 cycles), 2500 cycles, and 10,000 cycles |
Universal testing machine | FS at all thermocycling periods: CAD/CAM milled PMMA ≈ 3D-Printed composite > conventional bis-acrylic > conventional MMA Thermocycling periods influence the flexural strength of each tested group |
Digholkar et al., 2016 [36] |
Mean FS: (A) Heat-activated PMMA: 95.58 ± 12.444 MPa |
Mean FS: (B) Ceramill TEMP: 104.20 ±12.777 MPa |
Mean FS: (C) E-Dent 100: 79.54 ± 10.130 MPa |
N/M | Universal testing machine | FS: CAD/CAM-milled PMMA > Conventional heat activated PMMA > 3D-printed Microhybrid filled composite |
Simoneti et al., 2022 [53] | Mean FS in MPa: (A) Dencor (PMMA): 69.2 ± 8.8 (B) Yprov Bis-acryl (Bis-acryl resin): 75.0 ± 8.2 |
N/A | Mean FS in MPa: (C) PA2201 (SLS resin): 77.3 ± 3.1 (D) Gray Resin (SLA resin): 48.9 ± 1.2 |
Mechanical fatigue simulation: 120,000 cycles performed to simulate 6 months of clinical use |
Universal testing machine | FS: 3D-Printed SLS > conventional Bis-acrylic > conventional PMMA > 3D-Printed SLA resin |
Pantea et al., 2022 [31] | Mean FS in MPa: (A) Duracyl: 88 ±10 (B) Superpont C+B: 76 ± 7 |
N/A | Mean FS in MPa: (C) NextDent C&B MFH: 141 ± 17 (D) HARZ Labs Dental Sand: 143 ± 15 |
N/M | Universal testing machine | Flexural strength: 3D-Printed PMMA > conventional PMMA |
IQR: Interquartile range; N/A: Not Applicable; N/M: Not Mentioned.
Table 12.
Author and Year | Mean Elastic Modulus of Conventional Resin (Mpa) | Mean Elastic Modulus for CAD/CAM Milled Resin (MPa) | Mean Elastic Modulus for 3D-Printed Resin (MPa) | Exposure Agent/Aging Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Tahayeri et al., 2018 [37] | (A) Jet ~1500 (B) Integrity ~2700 |
N/A | (C) NextDent C&B resin ~1700 | N/M | Universal testing machine | Elastic Modulus: Conventionally fabricated bis-acrylic > 3D-printed PMMA > conventionally fabricated PMMA |
Simoneti et al., 2022 [53] | (A) Decor Acrylic resin: 859.4 ± 46.3 (B) Yprov Bisacryl: 997.3 ±108.5 |
N/A | (C) PA2201 (SLS resin): 452.4 ± 35.8 (D) Gray Resin (SAL resin): 513.3 ± 29.7 |
Mechanical fatigue simulation: 120,000 cycles, Simulating 6 months of clinical use |
Universal testing machine |
Elastic Modulus: Conventionally fabricated PMMA and bis-acrylic > 3D-printed PMMA |
Crenn et al., 2022 [29] | (A) Integrity: 3977 ± 878.2 (B) Unifast: 2382 ± 225.8 |
N/A | (C) PLA Bio source: 3784 ± 98.9 (D) Temporary CB: 4607 ± 213.8 |
Storage at ambient temperature for 1 week | Universal testing machine |
Elastic Modulus: 3D-printed esters > Conventional bis-acrylic > 3D-Printed poly lactic > Conventional MMA. |
N/A: Not Available; N/M: Not Mentioned.
Table 13.
Author and Year | Toughness for Conventional Resin | Toughness for CAD/CAM Milled Resin | Toughness for 3D-Printed Resin | Exposure Agent/Aging Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Tas¸ın et al., 2022 [30] | Median in MJ/m3 (A) Temdent Classic (PMMA) Thermocycling: (i) 0 cycles: 1.82 (ii) 2500 cycles: 1.31 (iii) 10,000 cycles: 0.96 (B) Protemp (Bis-Acryl) Thermocycling: (i) 0 cycles: 2.47 (ii) 2500 cycles: 2.47 (iii) 10,000 cycles: 1.54 |
Median in MJ/m3 (C) Duo Cad (PMMA): Thermocycling: (i) 0 cycles: 4.93 (ii) 2500 cycles: 4.59 (iii) 10,000 cycles: 3.70 |
Median in MJ/m3 (D) Temporis (composite resin): Thermocycling: (i) 0 cycles: 3.63 (ii) 2500 cycles: 3.09 (iii) 10,000 cycles: 2.20 |
Thermocycling | Universal testing machine | Toughness after thermocycling 10,000 cycles: CAD/CAM Milled PMMA > 3D-printed composite resin > conventional Bis-acrylic > conventional PMMA |
Table 14.
Author and Year | Mean Peak Stress for Conventional Resin | Mean Peak Stress for CAD/CAM Milled Resin | Mean Peak Stress for 3D-printed Resin | Exposure Agent/Aging Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Tahayeri et al., 2018 [37] | (A) Jet: ≅65 MPa (B) Integrity: ≅90 MPa |
N/A | (C) NextDent C&B resin: ≅95 MPa | N/M | Universal testing machine | Peak stress: 3D-printed NextDent > Conventionally fabricated Integrity > conventionally fabricated Jet |
Simoneti et al., 2022 [53] | (A) Dencor (PMMA): 114.6 ± 14.6 N (B) Yprov Bisacryl (Bis-acryl resin) 131.1 ± 2.2 N |
N/A | (C) PA 2201 (SLS resin): 133.7 ± 4.4 N (D) Gray Resin (SLA resin): 58.7 ± 2.2 N |
Mechanical fatigue simulation: 120,000 cycles simulating 6 months of clinical use | Universal testing machine |
Peak stress: 3D-Printed SLS > Conventional Bisacrylic > conventional PMMA > 3D-Printed SLA |
N/A: Not Applicable; N/M: Not Mentioned.
Table 15.
Author and Year | Resilience for Conventional Resin | Resilience for CAD/CAM Milled Resin | Resilience for 3D-Printed Resin | Exposure Agent/Aging Technique | Testing Machine Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|
Tas¸ın et al., 2022 [30] | Median in (MJ/m3) (A) Temdent Classic (PMMA): Thermocycling: (i) 0 cycles: 0.77 (ii) 2500 cycles: 0.64 (iii) 10,000 cycles: 0.53 (B) Protemp (Bis-Acryl): Thermocycling: (i) 0 cycles: 0.98 (ii) 2500 cycles: 0.81 (iii) 10,000 cycles: 0.72 |
Median in (MJ/m3) (C) Duo Cad (PMMA): Thermocycling: (i) 0 cycles: 1.04 (ii) 2500 cycles: 0.93 (iii) 10,000 cycles: 0.85 |
Median in (MJ/m3) (D) Temporis (composite resin): Thermocycling: (i) 0 cycles: 1.12 (ii) 2500 cycles: 1.03 (iii) 10,000 cycles: 0.74 |
Thermocycling | Universal testing machine | Resilience results after thermocycling for 10,000 cycles: CAD/CAM milled PMMA > 3D-Printed composite resin > Conventional Bisacrylic > conventional PMMA |
2.5. Quality Assessment of Included Studies
As all the selected studies were in vitro studies, so the Modified CONSORT scale for in vitro studies given by Faggion C. [33,34] was used to assess the quality of the included studies. The fourteen items included in this scale were as follows: Item 1: Structured abstract. Items 2a and 2b are related to the introduction. Item 2a: scientific background and explanation of rationale; Item 2b: Introduction should have specific objectives and/or hypotheses). Items 3 to 10 are related to Methodology. Item 3: intervention for each group; Item 4: Completely defined, pre-specified primary, and secondary measures of outcome; Item 5: sample size determination; Item 6: Method used to generate the random allocation sequence; Item 7: Mechanism used to implement the random allocation sequence; Item 8: Who generated the random allocation sequence; Item 9: If done, who was blinded after assignment to intervention and how; Item 10: Statistical methods used to compare groups for primary and secondary outcomes; Item 11: For each primary and secondary outcome, results for each group and the estimated size of the effect and its precision (for example 95% confidence interval); Item 12: Trial limitations; Item 13: Sources of funding and other support, role of funders; Item 14: Where the full trial protocol can be accessed, if available (Table 4).
2.6. Quantitative Assessment
Review Manager 5.4.1 was used to perform a Meta-analysis in Non-Cochrane Review mode [35]. Since all the physical and mechanical properties were measured and reported in studies on a continuous scale, inverse variance was used as the statistical method. The fixed-effect model was used under the assumption that all effect estimates are estimating the same underlying intervention effect. Since the measurement tools and scales varied among different studies, standardized mean difference was used. A 95% confidence interval was used to express the results of individual studies and the pooled result. Chi-square was used to measure heterogeneity, and a p-value < 0.05 was considered significant. I2 was also calculated and reported in the results. Statistical significance was calculated for the overall effect; if p was less than 0.05, the null hypothesis was rejected.
3. Results
3.1. Identification and Screening
This literature review compared the physical and mechanical properties of resins used for fabricating provisional crowns and FDPs by 3D-printing with those provisional resins used for CAD/CAM milling and other conventional techniques. For ease of understanding, the results of each physical and mechanical property were tabulated in separate tables (Table 5, Table 6, Table 7, Table 8, Table 9, Table 10, Table 11, Table 12, Table 13, Table 14 and Table 15).
Eight hundred and ninety-six titles were recognized from the primary search on the selected electronic databases. On checking, 107 titles were found to be duplicates and were excluded. After reviewing the titles and abstracts, 710 articles were rejected as they did not meet the inclusion and exclusion criteria. Full texts of the remaining 79 articles were reviewed, and secondary articles were searched manually from the references of these articles, but no more relevant articles were found. Out of the selected 79 articles, 15 were rejected, as they were discussing the properties of provisional 3D-printed resins without comparing them with CAD/CAM milled and other conventional provisional resins. Thirty-four articles were rejected as they compared other properties (other than physical and mechanical), and four were rejected as they were comparing provisional 3D-printed resins with definitive restorative materials. Finally, one article was rejected as it discussed the properties of 3D-printed resins under the trial phase. Thus, 25 articles were finally included in this systematic review for qualitative analysis. Out of 25 articles, only 12 provided comparative data and were included for quantitative analysis (Figure 1).
3.2. Quality Assessment of Included Studies
All twenty-five studies included in this review were in vitro studies. A total of 221 out of 375 (58.93%) entries were positively reported. All studies reported items related to abstract, introduction, intervention, outcome, statistical method, and results (Items 1–4, 10, and 11). Fifteen studies addressed the trial limitations (Item 12) and provided information related to funding sources (Item 13). Only six studies mentioned the procedure of calculating the sample size of the specimens (Item 5), while five studies gave details related to the accessibility of the full trial protocol (Item 14). Only four studies described the method used to generate random allocation sequence (Item 6), with one of them reporting the allocation concealment mechanism briefly (Item 7). Details related to the blinding of the examiners and the details of the researcher who generated the random allocation were not reported by any of the studies (Item 8 and 9) (Table 4).
3.3. Study Characteristics
The majority of the studies (21 out of 25) included in this review were published between 2020 and 2022, while four were published between the years 2016 and 2019. All the included articles were in vitro studies. Nineteen articles analyzed and compared the mechanical properties, four analyzed physical properties, and two articles analyzed both physical and mechanical properties. Some of the studies focused on one particular character, while others studied multiple characteristics at the same time (Table 3).
3.4. Results of Studies Analyzing the Physical Properties
3.4.1. Color Change
Five studies compared the change in the color values of 3D-printed interim resins with other materials (Table 5).
-
(i)
Comparing the change in color values of MMA-based 3D-printed provisional resins: Three studies reported a greater change in the color values of MMA-based 3D-printed resins when compared to CAD/CAM milled PMMA resins [28,44,45].
Two studies provided data for the meta-analysis to compare color changes between 3D-Printed MMA Resins and CAD/CAM Milled PMMAs. There was a statistically significant heterogeneity between the studies, with I2 = 94%. The results were inconclusive, favoring 3D-Printed MMA (p = 0.23) (Figure 2).
-
(ii)
Comparing the change in color values of hybrid composite-based 3D-printed provisional resins: Studies by Atria et al. [42] reported a greater change in color for hybrid composite-based 3D-printed provisional resins when compared to conventional bis-acrylic and PMMA resins. On the contrary, Taşın et al. [48] and Song et al. [44] reported greater change in color for conventional resins. Compared to CAD/CAM milled PMMA resins, a greater change in color was reported in 3D-printed hybrid composite resins [15,19].
Two studies provided data for the meta-analysis to compare color changes between 3D-printed hybrid resin and conventional PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 96%. The results were inconclusive, favoring conventional PMMA resin (p = 0.40) (Figure 3).
Two studies provided data for meta-analysis to compare color changes between 3D-printed hybrid resin and conventional bBis-acrylic resin. There was a statistically significant heterogeneity between the studies, with I2 = 96%. The results were inconclusive, favoring conventional bBis-acrylic resin (p = 0.12) (Figure 4).
3.4.2. Water Sorption and Solubility
Two studies compared the water sorption and solubility of 3D-printed interim resins with other materials (Table 6). The water sorption of 3D-printed PMMA resins was reported to be higher than conventional polycarbonate resins and lower than conventional PMMA resins [28]. For 3D-printed photopolymer resins, the water sorption was reported to be higher than conventional bis-acrylic and CAD/CAM milled PMMA resins and lower than conventional PMMA resins [44]. The solubility of the 3D-printed PMMA resins was reported to be higher than conventional polycarbonate and PMMA resins [28]. For 3D-printed photopolymer resins, the solubility was higher than conventional PMMA, conventional bis-acrylic, and CAD/CAM milled PMMA resins [44].
3.5. Results of Studies Analyzing the Mechanical Properties
3.5.1. Fracture Strength
Eight studies analyzed and compared the fracture strength of 3D-printed resins with CAD/CAM milled and/or conventionally fabricated resins used for the fabrication of provisional crowns and FDPs (Table 7).
-
(i)
Comparing the fracture strength of PMMA-based 3D-printed provisional resins: Three studies reported higher FS when compared to PMMA-based CAD/CAM milled resins [38,39,40]. One study reported contrasting results of lower FS when compared to PMMA-based CAD/CAM milled resins [50], and one study each reported higher FS when compared to conventional MMA [39] and bis-acrylic resins [40]. A study by Reeponmaha et al. [16] reported higher FS MMA-based 3D-printed resins when compared to PMMA-based CAD/CAM milled and conventional resins.
Five studies provided data for the meta-analysis to compare the fracture strength between 3D-printed PMMA resin and CAD/CAM milled PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 93%. The results were inconclusive, favoring 3D-printed PMMA (p = 0.18) (Figure 5).
Two studies provided data for the meta-analysis to compare the fracture strength between 3D-Printed PMMA resin and conventional PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 87%. However, both the studies favored 3D-printed PMMA resin, and the 95% confidence interval did not include 0, i.e., no effect. Thus, the pooled estimate favored 3D-printed PMMA resin with p < 0.0001 (Figure 6).
-
(ii)
Comparing the fracture strength of bis-acrylic and other photopolymer hybrid 3D-printed provisional resins: the FSs of 3D-printed bis-acrylic resin [48], micro-hybrid resin [46], photopolymer resin [52], and UDMA-based resins [50] were reported to be lower than PMMA-based CDA/CAM resins. A study by Henderson et al. [51] reported that bis-acrylic-based 3D-printed resins have lower FS when compared to bis-acrylic-based conventional resins.
Two studies provided data for the meta-analysis to compare the fracture strength between 3D-printed PMMA resin and conventional bis-acrylic resin. There was a statistically significant heterogeneity between the studies, with I2 = 90%. The results were inconclusive, favoring 3D-printed PMMA resin (p = 0.09) (Figure 7).
3.5.2. Microhardness
Four studies compared the microhardness of 3D-printed interim resins with other materials. Two studies measured Vickers hardness [29,53], while the other two measured knop hardness [36,49] (Table 8).
-
(i)
Comparing the hardness of MMA-based 3D-printed provisional resins: Two studies reported lower hardness values of MMA-based 3D-printed resins when compared to conventional MMA [49,53] and conventional bis-acrylic interim resins [53], respectively. Moreover, a study by Revilla-León et al. [49] reported higher hardness values for 3D-printed MMA-based interim resins when compared to conventional bis-acrylic interim resins.
-
(ii)
Comparing hardness of micro-filled and polylactic-acid-based 3D-printed provisional resins: Digholkar et al. [36] reported higher hardness values for 3D-printed micro-filled resins when compared to conventional PMMA-based interim resins, whereas Crenn et al. [29] reported PMMA-based conventional resins to have higher hardness values when compared to 3D-printed polylactic-acid-based interim resins.
3.5.3. Surface Roughness
Four studies compared the surface roughness of 3D-printed interim resins with other materials (Table 9).
-
(i)
Comparing the surface roughness of MMA-based 3D-printed provisional resins: Myagmar et al. [47] reported lower surface roughness values for MMA-based 3D-printed resins compared to PMMA-based conventional resins and CAD/CAM milled interim resins.
Two studies provided data for meta-analysis to compare Surface Roughness between 3D-printed PMMA resin and conventional PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 78%. Both studies favored the conventional PMMA with a 95% confidence interval. The pooled estimate favored conventional PMMA resin with a p-value < 0.0001 (Figure 8).
Two studies provided data for the meta-analysis to compare the surface roughness between 3D-printed PMMA resin and conventional bis-acrylic resin. There was a statistically significant heterogeneity between the studies, with I2 = 90%. The results were inconclusive, favoring conventional bis-acrylic resin (p = 0.09) (Figure 9).
-
(ii)
Comparing the surface roughness of hybrid and other 3D-printed provisional resins: One study [42] showed that hybrid 3D-printed resins have a higher surface roughness when compared to conventional PMMA, conventional bis-acrylic, and CAD/CAM milled PMMA-based resins. However, the results of a study by Taşın et al. [48] gave contradictory results, with hybrid 3D-printed resins displaying a lower surface roughness when compared to conventional PMMA, conventional bis-acrylic, and CAD/CAM milled PMMA-based resins. Simoneti et al. [53] reported that the surface roughness of SLS 3D-printed resins was higher, and that of SLA-based 3D-printed resins was lower when compared to conventional PMMA and bis-acrylic-based interim resins.
Two studies provided data for the meta-analysis to compare the surface roughness between 3D-printed hybrid composite resins and conventional PMMA resins. There was a statistically significant heterogeneity between the studies, with I2 = 98%. The results were inconclusive, favoring 3D-printed hybrid composite resin (p = 0.09) (Figure 10).
Two studies provided data for the meta-analysis to compare the surface roughness between 3D-hybrid composite resin and conventional bis-acrylic resin. There was a statistically significant heterogeneity between the studies, with I2 = 97%. The studies showed varied results, one favoring each side. The pooled estimate favored 3D-printed hybrid composite resin with a p-value = 0.04 (Figure 11).
Two studies provided data for the meta-analysis to compare the surface roughness between 3D-hybrid composite resin and CAD/CAM milled PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 97%. The studies showed varied results, one favoring each side. The pooled estimate favored 3D-printed hybrid composite resin with a p-value = 0.02 (Figure 12).
3.5.4. Wear Resistance
Four studies compared the wear resistance of 3D-printed interim resins with other materials (Table 10).
Comparing the wear resistance of MMA-based 3D-printed provisional resins: The wear resistance of MMA-based 3D-printed provisional resins was reported to be higher than the wear resistance of PMMA-based conventional and CAD/CAM milled 3D-printed interim resins [26,27,47,50].
Two studies provided data for the meta-analysis to compare the wear resistance between 3D-printed PMMA resin and CAD/CAM milled PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 89%. Both studies favored the 3D-printed PMMA resin with a 95% confidence interval. The pooled estimate favored 3D-printed PMMA resin with a p-value < 0.00001 (Figure 13).
3.5.5. Flexural Strength
Six studies compared the flexural strength values of 3D-printed interim resins with other materials (Table 11).
-
(i)
Comparing the flexural strength of MMA-based 3D-printed provisional resins: Two studies reported higher flexural strength values of MMA-based 3D-printed resins when compared to conventional MMA [31,43] and CAD/CAM milled PMMA resin [43].
Two studies provided data for the meta-analysis to compare the flexural strength between 3D-Printed PMMA resin and CAD/CAM milled PMMA resin. There was a statistically significant heterogeneity between the studies, with I2 = 80%. Both studies favored the 3D-printed PMMA resin with a 95% confidence interval. The pooled estimate favored 3D-printed PMMA resin with a p-value < 0.0001 (Figure 14).
-
(ii)
Comparing the flexural strength of composite-based 3D-printed provisional resins: Taşın et al. reported higher flexural strength values of composite-based 3D-printed resins compared to conventional MMA and conventional bis-acrylic-based resins [30], whereas a study by Digholkar et al. reported lower flexural strength values compared to CAD/CAM milled PMMA and conventional heat cure PMMA-based resins [37]. Contrasting results were reported when the flexural strengths of SLA 3D-printed resins were compared with conventional PMMA and bis-acrylic resins. Crenn et al. [29] reported higher flexural strength values for 3D-printed resins, while Simoneti et al. [53] reported higher values for conventional resins.
3.5.6. Elastic Modulus
Five studies compared the elastic modulus of 3D-printed interim resins with other materials (Table 12).
-
(i)
Comparing the elastic modulus of MMA-based 3D-printed provisional resins: Two studies reported higher elastic modulus values of MMA-based 3D-printed resins when compared to conventional MMA [31,37], whereas a study by Simoneti et al. reported lower elastic modulus values when compared to conventional PMMA-based resins [53]. Two studies reported lower elastic modulus values of MMA-based 3D-printed resins compared to conventional bis-acrylic resins [37,53].
-
(ii)
Comparing the elastic modulus of composite-based, ester-based, and polylactic-acid-based 3D-printed provisional resins: Crenn et al. [29] reported higher elastic modulus values for ester-based and polylactic-acid-based 3D-printed resins when compared to conventional PMMA and bis-acrylic-based resins. Taşın et al. [30] reported higher elastic modulus values for composite-based 3D-printed resins compared to conventional PMMA, CAD/CAM PMMA, and conventional bis-acrylic-based resins.
3.5.7. Toughness, Peak Strain, and Resilience
Two studies compared the peak strain values, and one each studied toughness and resilience of 3D-printed interim resins with other materials (Table 13, Table 14 and Table 15).
Taşın et al. [30] reported that the resilience and toughness of 3D-printed composite resins is higher than conventional PMMA and bis-acrylic resins but lower than CAD/CAM milled PMMA resins.
When peak stress values were compared, Tahayeri et al. [37] reported higher values for 3D-printed PMMA when compared to conventional bis-acrylic and PMMA-based resins. The study by Simoneti et al. [53] reported that peak stress values for conventional resins (bis-acrylic and PMMA) were higher than 3D-printed SLA resins but lower than 3D-printed SLS resins.
4. Discussion
The introduction of CAD/CAM technology in the field of fixed prosthodontics has improved the quality of treatment provided to the patients [54]. This systematic review and meta-analysis is the first of its kind to analyze and document all the available studies comparing the mechanical and/or physical properties of the 3D-printed provisional crown and FPD materials with CAD/CAM milled and/or conventional provisional resins. All twenty-five papers included were in vitro studies [16,26,27,28,29,30,31,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52]. The overall findings reveal that the mechanical and physical properties of the provisional crown and FDP materials are affected by the technique of fabrication and composition of the tested materials. Three-dimensionally printed provisional materials have shown significantly different mechanical and physical properties. Thus, the tested null hypothesis is rejected. The mechanical and physical properties of 3D-printed provisional resins in comparison to conventional and CAD/CAM milled will be discussed.
4.1. Physical Properties
Three physical properties (color stability, solubility, and water sorption) were evaluated in the selected articles. In general, most of the studies reported that, irrespective of the composition, the 3D-printed provisional crown and FDP materials displayed poor physical properties when compared to CAD/CAM milled and conventionally processed provisional restorative materials. Three studies [28,44,45] that compared the color stability of 3D-printed PMMA resins reported that they have poor color stability when compared to CAD/CAM milled PMMA resins. The studies by Atria et al. [15] and Taşın et al. [19] reported a poor color stability of 3D-printed hybrid composite resins compared to CAD/CAM milled PMMA, conventional PMMA, and conventional bis-acrylic provisional resins. However, two studies [44,48] reported better color stability for 3D-printed hybrid composite resins compared to conventional PMMA and bis-acrylic resins.
The poor color stability of 3D-printed provisional resins has been attributed to multiple reasons: CAD/CAM milled PMMA resins have a high polymerization rate, undergo industrial manufacturing, and have high crosslinking, thus making them dense in comparison to 3D-printed PMMA resins, which have low polymerization rates leading to poor surface integrity and color stability [14,36,37,42,55,56,57,58,59,60]. Studies reported that CAD/CAM milled and conventionally processed PMMA resins have MMA (methylmethacrylate)-based monomers that are hydrophobic, whereas HDMA (hexamethylene glycol dimethacrylate), which is the monomer used in light polymerized resins, is hydrophilic in nature. Thus, the higher polarity of 3D-printed PMMA resins could also be a reason for the poor color stability [48,61,62,63,64,65]. Studies by Atria et al. [42] and Yao et al. [45] evaluated the optical properties of 3D-printed hybrid composite resins. The poor color stability could be attributed to a lack of filler particles in these resins, thus leading to an increase in surface roughness. Song et al. [44] attributed the poor color stability to the presence of an uncured layer on the 3D-printed resins. The quantity of residual monomers, high solubility, and water sorption are also additive factors that influence the color stability of 3D-printed materials [28,66].
Myagmar et al. [47] and Atrial et al. [42] tested the color stability after artificial aging by thermocycling, whereas Shin et al. [28], Song et al. [44], and Taşın et al. [48] immersed the test specimens in different staining solutions (coffee, grape juice, curry, black tea, cola, and red wine). In general, as the immersion duration increases, the extent of discoloration increases for the tested specimens. The extent of color change also varied depending upon the type of staining solution. Studies [45,58,59,60,61] have shown that the application of surface glaze/sealant materials significantly improves the color stability and decreases the surface roughness of 3D-printed materials.
Water sorption by acrylic resins can affect the dimensional stability and can lead to failure of the prosthesis [67,68,69], whereas a high solubility of acrylic resins can lead to the presence of more unreacted monomers, which can adversely affect oral tissues. Thus, for a material to be successful, it should have minimal water sorption and solubility [70]. Two studies evaluated the sorption and solubility of 3D-printed provisional resins [28,44]. They reported that the water sorption and solubility of 3D-printed PMMA and photopolymer provisional resins were higher than CAD/CAM milled PMMA and conventional bis-acrylic resins, while the water sorption is less than in conventional PMMA provisional resins. Perea-Lowery et al. [71] and Berli et al. [68] correlated the high water sorption and solubility of 3D-printed resins to the polymerization technique. The 3D-printed materials are printed in layers, and water can enter in these layers, causing movement in the polymer chains, which can cause dimensional changes. In addition to this, the presence of free monomers in 3D-printed materials due to the low polymerization degree increases the water sorption [68,71,72].
4.2. Mechanical Properties
Mechanical properties discussed in the articles included in this systematic review and meta-analysis are fracture strength, microhardness, surface roughness, wear resistance, flexural strength, elastic modulus, peak stress, toughness, and resilience.
Fracture strength, flexural strength, peak stress, elastic modulus, and wear resistance are some of the mechanical properties which were found to be better for 3D-printed resins when compared to conventional and CAD/CAM milled provisional materials.
Three-dimensionally printed materials are fabricated by a layering technique; thus, there is a chemical bond between the layers [38]. The technique of fabrication affects the mechanical properties of 3D-printed resins. The authors of [38,73] reported that orientation during printing affects the mechanical properties. Vertical build orientation causes layers to be deposited perpendicular to the direction of the load application. So, these materials display superior mechanical properties compared to those printed in horizontal orientation (as layer deposition is parallel to load direction). The layer thickness during the printing process also effects the mechanical properties of these materials. Ibrahim et al. [38] and Tahayeri et al. [37] stated that the lower the layer thickness of printing is, the more layer-to-layer interfaces that will be available; thus, each layer will be polymerized in a better way, which will increase the mechanical properties of these materials. After fabrication, 3D-printed materials are subjected to post-curing, which increases the degree of conversion, thus leading to lower residual monomers and increased mechanical properties [36,41]. Park et al. [26] and Mayer et al. [50] reported that 3D-printed provisional resins contain multiple different methacrylate resins and further additives. This difference in composition can be the reason for their superior wear resistance properties.
In conventional provisional resins, which are mixed manually or by using automixing units, there are high chances of incorporating air bubbles and porosities, which can be a reason for their poor mechanical properties [16,39]. Studies reported inferior mechanical properties of CAD/CAM milled provisional resins compared to 3D-printed resins. Monomer release from PMMA Blank after aging [55], the presence of fine grooves and lines on the surface of milled resins (due to milling process) [37,74], and the presence of higher weight percentages of carbon and oxygen (representing organic part) in CAD/CAM milled provisional resins [38] can be some of the possible reasons for such behavior. On the contrary, the shrinkage of specimens during the building and post-curing processes can be a reason why few studies reported the poor mechanical properties of 3D-printed resins compared to others [36,38,75].
Toughness, resilience, and microhardness are some of the mechanical properties that are poor for 3D-printed composite-based resins compared to CAD/CAM milled PMMA resins. For long-term provisional restorations, the resiliency should be higher to avoid failures. The dense cross-linking and homogenous structure of CAD/CAM milled PMMA resins make them less prone to hydrolytic degradation when compared to conventional and 3D-printed resins [30]. In addition, the difference in composition and manufacturing technique [29,36,49,53] are some of the causes for 3D-printed resins to have these properties inferior to other tested groups.
Studies have shown contrasting results when comparing the surface roughness of 3D-printed materials and other provisional materials. Atria et al. [15] reported high surface roughness of 3D-printed hybrid resins compared to conventional and CAD/CAM-printed PMMA resins. They stated that while printing these resins factors such as curing time, orientation, and the post-curing process may play an important role. In addition to that, they used unfilled 3D resins. Contrary to this, Taşın et al. [48] found that 3D-printed hybrid resins have less surface roughness when compared to conventional and CAD/CAM PMMA resins. They stated that due to the milling and polishing process, there could be additional surface defects that can increase the surface roughness. In general, it can be stated that the surface roughness of 3D-printed resins is affected by the composition of tested resin and printing orientation [47].
This systematic review employed a comprehensive search strategy, and independent assessments of the reviewers were used during article selection to avoid bias. These are the highlights of this review. All the articles discussing the physical and mechanical properties of 3D-printed provisional materials were evaluated to ensure that no relevant article is missed.
4.3. Limitations
Studies included in this systematic review had medium-to-high-quality methodologies, but the risk of bias was high. High heterogeneity was observed in all meta-analyses, and most of the meta-analyses had contributions from two studies only. Most of the pooled estimates showed inconclusive results. Thus, more studies with uniformity in material and measurement techniques are needed to make conclusive statements from meta-analysis regarding the physical and mechanical properties of 3D-printed provisional resin materials. This systematic review and meta-analysis focused only on physical and mechanical properties. However, there are other parameters, such as accuracy, dimensional stability, marginal adaptation, internal adaptation, etc., which play essential roles in decision making while selecting the best material to be used for provisionalization of crowns and FDPs. Further systematic reviews are recommended to cover these aspects of the materials.
5. Conclusions
The following conclusions can be drawn from this systematic review and meta-analysis:
When compared to conventional and CAD/CAM milled provisional resin materials, 3D-printed provisional crown and FDP resins have: (a) superior mechanical properties in terms of fracture strength, flexural strength, elastic modulus, peak stress, and wear resistance; (b) inferior mechanical properties in terms of toughness, resilience, and microhardness; (c) contrasting results in terms of surface roughness; and (d) inferior physical properties in terms of color stability, water sorption, and solubility.
In vitro studies should follow blinding protocols to avoid bias.
Three-dimensionally printed provisional crowns and FDP materials can be used as an alternative to conventional and CAD/CAM milled long-term provisional materials.
Acknowledgments
Authors would like to thank Puneet Gupta for his assistance with the meta-analysis.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/polym14132691/s1. Table S1: PRISMA 2020 Main Checklist.
Author Contributions
Conceptualization, S.J., M.S., M.E.S. and A.A.A.O.; methodology, S.J., M.E.S., M.S., S.M.A., A.A.A.O., H.F.B., S.G.G. and A.H.M.; software, M.H.D.A.W., A.A.Z., H.F.B., H.A. and A.J.H.; validation, S.J., M.E.S., M.S., A.A.A.O., S.G.G., M.F.S. and K.M.; formal analysis, S.J., M.H.D.A.W., S.G.G. and K.M.; investigation, S.J., M.H.D.A.W., S.M.A., A.H.A., A.A.Z. and A.J.H.; resources, A.H.A., A.A.Z., H.F.B., A.J.H., M.F.S., A.H.M. and K.M.; data curation, S.J., S.M.A., A.H.A., A.A.Z., S.G.G. and H.A.; writing—original draft preparation, S.J., M.E.S., M.S., A.A.A.O. and S.G.G.; writing—review and editing, S.J., M.E.S., M.S., M.H.D.A.W., S.M.A., A.H.A., A.A.Z., H.F.B., H.A., A.J.H., M.F.S., A.H.M. and K.M.; visualization, S.J., H.F.B., H.A., A.J.H., M.F.S. and A.H.M.; supervision, S.J., M.H.D.A.W., S.M.A., A.H.A., H.A., M.F.S., A.H.M. and K.M.; project administration, S.J., M.E.S. and A.A.A.O. All authors have read and agreed to the published version of the manuscript.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Conflicts of Interest
The authors declare no conflict of interest.
Funding Statement
This research received no external funding.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Alt V., Hanning M., Wostmann B., Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD/CA versus directly fabricated restorations. Dent. Mater. 2001;27:339–347. doi: 10.1016/j.dental.2010.11.012. [DOI] [PubMed] [Google Scholar]
- 2.Khng K.Y.K., Ettinger R.L., Armstrong S.R., Lindquist T., Gratton D.G., Qian F. In vitro evaluation of the marginal integrity of CAD/CAM interim crowns. J. Prosthet. Dent. 2016;115:617–623. doi: 10.1016/j.prosdent.2015.10.002. [DOI] [PubMed] [Google Scholar]
- 3.Yao J., Li J., Wang Y., Huang H. Comparison of the flexural strength and marginal accuracy of traditional and CAD/CAM interim materials before and after thermal cycling. J. Prosthet. Dent. 2014;112:649–657. doi: 10.1016/j.prosdent.2014.01.012. [DOI] [PubMed] [Google Scholar]
- 4.Rayyan M.M., Aboushelib M., Sayed N.M., Ibrahim A., Jimbo R. Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually. J. Prosthet. Dent. 2015;114:414–419. doi: 10.1016/j.prosdent.2015.03.007. [DOI] [PubMed] [Google Scholar]
- 5.Singla M., Padmaja K., Arora J., Shah A. Provisional restorations in fixed prosthodontics. Int. Dent. Res. 2014;1:148–151. [Google Scholar]
- 6.Lodding D.W. Long-term esthetic provisional restorations in dentistry. Curr. Opin. Cosmet. Dent. 1997;4:16–21. [PubMed] [Google Scholar]
- 7.Trushkowsky R.D. Fabrication of a fixed provisional restoration utilizing a light-curing acrylic resin. Quintessence Int. 1992;23:415–419. [PubMed] [Google Scholar]
- 8.Burns D.R., Beck D.A., Nelson S.K. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: Report of the committee on research in fixed prosthodontics of the academy of fixed prosthodontics. J. Prosthet. Dent. 2003;90:474–497. doi: 10.1016/S0022-3913(03)00259-2. [DOI] [PubMed] [Google Scholar]
- 9.Frazer R.Q., Byron R.T., Osborne P.B., West K.P. PMMA: An essential material in medicine and dentistry. J. Long-Term Eff. Med. Implant. 2005;15:629–639. doi: 10.1615/JLongTermEffMedImplants.v15.i6.60. [DOI] [PubMed] [Google Scholar]
- 10.Federick D.R. The provisional fixed partial denture. J. Prosthet. Dent. 1975;34:520–526. doi: 10.1016/0022-3913(75)90039-6. [DOI] [PubMed] [Google Scholar]
- 11.Bidra A.S., Taylor T.D., Agar J.R. Computer-aided technology for fabricating complete dentures: Systematic review of his-torical background, current status, and future perspectives. J. Prosthet. Dent. 2013;109:361–366. doi: 10.1016/S0022-3913(13)60318-2. [DOI] [PubMed] [Google Scholar]
- 12.Schweiger J., Stumbaum J., Edelhoff D., Güth J.-F. Systematics and concepts for the digital production of complete den-tures: Risks and opportunities. Int. J. Comput. Dent. 2018;21:41–56. [PubMed] [Google Scholar]
- 13.Millet C., Virard F., Dougnac-Galant T., Ducret M. CAD-CAM immediate to definitive complete denture transition: A digital dental technique. J. Prosthet. Dent. 2020;124:642–646. doi: 10.1016/j.prosdent.2019.10.025. [DOI] [PubMed] [Google Scholar]
- 14.Jain S., Sayed M., Ahmed W.M., Halawi A.H.A., Najmi N.M.A., Aggarwal A., Bhandi S., Patil S. An in-vitro study to evaluate the effect of denture cleansing agents on color stability of denture bases fabricated using CAD/CAM milling, 3D-printing and conventional techniques. Coatings. 2021;11:962. doi: 10.3390/coatings11080962. [DOI] [Google Scholar]
- 15.Abdullah A.O., Tsitrou E.A., Pollington S. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns. J. Appl. Oral Sci. 2016;24:258–263. doi: 10.1590/1678-775720150451. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Reeponmaha T., Angwaravong O., Angwarawong T. Comparison of fracture strength after thermo-mechanical aging between provisional crowns made with CAD/CAM and conventional method. J. Adv. Prosthodont. 2020;12:218–224. doi: 10.4047/jap.2020.12.4.218. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Goodacre B.J., Goodacre C.J., Baba N.Z., Kattadiyil M.T. Comparison of denture base adaptation between CAD/CAM and conventional fabrication techniques. J. Prosthet. Dent. 2016;116:249–256. doi: 10.1016/j.prosdent.2016.02.017. [DOI] [PubMed] [Google Scholar]
- 18.Kattadiyil M.T., Jekki R., Goodacre C.J., Baba N.Z. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J. Prosthet. Dent. 2015;114:818–825. doi: 10.1016/j.prosdent.2015.08.001. [DOI] [PubMed] [Google Scholar]
- 19.Goodacre B.J., Goodacre C.J., Baba N.Z., Kattadiyil M.T. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques. J. Prosthet. Dent. 2018;119:108–115. doi: 10.1016/j.prosdent.2017.02.009. [DOI] [PubMed] [Google Scholar]
- 20.Janeva N.M., Kovacevska G., Elencevski S., Panchevska S., Mijoska A., Lazarevska B. Advantages of CAD/CAM versus conventional complete dentures—A review. Open Access Maced. J. Med. Sci. 2018;6:1498–1502. doi: 10.3889/oamjms.2018.308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Batisse C., Nicolas E. Comparison of CAD/CAM and conventional denture base resins: A systematic review. Appl. Sci. 2021;11:5990. doi: 10.3390/app11135990. [DOI] [Google Scholar]
- 22.Van Noort R. The future of dental devices is digital. Dent. Mater. 2012;28:3–12. doi: 10.1016/j.dental.2011.10.014. [DOI] [PubMed] [Google Scholar]
- 23.Alghazzawi T.F. Advancements in CAD/CAM technology: Options for practical implementation. J. Prosthodont. Res. 2016;60:72–84. doi: 10.1016/j.jpor.2016.01.003. [DOI] [PubMed] [Google Scholar]
- 24.Zaharia C., Gabor A.G., Gavrilovici A., Stan A.T., Idorasi L., Sinescu C., Negruțiu M.L. Digital dentistry—3D printing applications. J. Interdiscip. Med. 2017;2:50–53. doi: 10.1515/jim-2017-0032. [DOI] [Google Scholar]
- 25.Goodacre B.J., Goodacre C.J. Additive manufacturing for complete denture fabrication: A narrative review. J. Prosthodont. 2022;31:47–51. doi: 10.1111/jopr.13426. [DOI] [PubMed] [Google Scholar]
- 26.Park J.M., Ahn J.S., Cha H.S., Lee J.H. Wear resistance of 3D printing resin material opposing zirconia and metal antagonists. Materials. 2018;11:1043. doi: 10.3390/ma11061043. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Kessler A., Reymus M., Hickel R., Kunzelmann K.-H. Three-body wear of 3D printed temporary materials. Dent. Mater. 2019;35:1805–1812. doi: 10.1016/j.dental.2019.10.005. [DOI] [PubMed] [Google Scholar]
- 28.Shin J.-W., Kim J.-E., Choi Y.-J., Shin S.-H., Nam N.-E., Shim J.-S., Lee K.-W. Evaluation of the color stability of 3D-printed crown and bridge materials against various sources of discoloration: An in vitro study. Materials. 2020;13:5359. doi: 10.3390/ma13235359. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Crenn M.J., Rohman G., Fromentin O., Benoit A. Polylactic acid as a biocompatible polymer for three-dimensional print-ing of interim prosthesis: Mechanical characterization. Dent. Mater. J. 2022;41:110–116. doi: 10.4012/dmj.2021-151. [DOI] [PubMed] [Google Scholar]
- 30.Taşın S., Ismatullaev A. Comparative evaluation of the effect of thermocycling on the mechanical properties of conven-tionally polymerized, CAD-CAM milled, and 3D-printed interim materials. J. Prosthet. Dent. 2022;127:173.e1–173.e8. doi: 10.1016/j.prosdent.2021.09.020. [DOI] [PubMed] [Google Scholar]
- 31.Pantea M., Ciocoiu R.C., Greabu M., Totan A.R., Imre M., Țâncu A.M.C., Sfeatcu R., Spînu T.C., Ilinca R., Petre A.E. Compressive and flexural strength of 3D-printed and conventional resins designated for interim fixed dental prostheses: An in vitro comparison. Materials. 2022;15:3075. doi: 10.3390/ma15093075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Shamseer L., Moher D., Clarke M., Ghersi D., Liberati A., Petticrew M., Shekelle P., Stewart L.A., PRISMA-P Group Pre-ferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015: Elaboration and explanation. BMJ. 2015;349:g7647. doi: 10.1136/bmj.g7647. [DOI] [PubMed] [Google Scholar]
- 33.Faggion C.M. Guidelines for reporting pre-clinical in vitro studies on dental materials. J. Evid. Based Dent. Pract. 2012;12:182–189. doi: 10.1016/j.jebdp.2012.10.001. [DOI] [PubMed] [Google Scholar]
- 34.Krithikadatta J., Datta M., Gopikrishna V. CRIS guidelines (checklist for reporting in-vitro studies): A concept note on the need for standardized guidelines for improving quality and transparency in reporting in-vitro studies in experimental dental research. J. Conserv. Dent. 2014;17:301–304. doi: 10.4103/0972-0707.136338. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Review Manager (RevMan) Cochrane; London, UK: 2020. [(accessed on 23 May 2022)]. version 5.4.1. The Cochrane Collaboration. Available online: https://training-cochrane-org.vgharpa.vghtpe.gov.tw/online-learning/core-softwarecochrane-reviews/revman. [Google Scholar]
- 36.Madhav V.N.V., Digholkar S., Palaskar J. Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods. J. Indian Prosthodont. Soc. 2016;16:328–334. doi: 10.4103/0972-4052.191288. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Tahayeri A., Morgan M., Fugolin A.P., Bompolaki D., Athirasala A., Pfeifer C.S., Ferracane J.L., Bertassoni L.E. 3D printed versus conventionally cured provisional crown and bridge dental materials. Dent. Mater. 2018;34:192–200. doi: 10.1016/j.dental.2017.10.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Ibrahim A., Shehawy D.E., El-Naggar G. Fracture resistance of interim restoration constructed by 3D printing versus CAD/CAM technique (in vitro study) Ain Shams Dent. J. 2020;23:13–20. [Google Scholar]
- 39.Suralik K.M., Sun J., Chen C.-Y., Lee S.J. Effect of fabrication method on fracture strength of provisional implant-supported fixed dental prostheses. Prosthesis. 2020;2:325–332. doi: 10.3390/prosthesis2040030. [DOI] [Google Scholar]
- 40.Reymus M., Fabritius R., Keßler A., Hickel R., Edelhoff D., Stawarczyk B. Fracture load of 3D-printed fixed dental pros-theses compared with milled and conventionally fabricated ones: The impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin. Oral Investig. 2020;24:701–710. doi: 10.1007/s00784-019-02952-7. [DOI] [PubMed] [Google Scholar]
- 41.Revilla-León M., Umorin M., Özcan M., Piedra-Cascón W. Color dimensions of additive manufactured interim restora-tive dental material. J. Prosthet. Dent. 2020;123:754–760. doi: 10.1016/j.prosdent.2019.06.001. [DOI] [PubMed] [Google Scholar]
- 42.Atria P.J., Lagos I., Sampaio C.S. In vitro evaluation of surface roughness, color stability, and color masking of provisional restoration materials for veneers and crowns. Int. J. Comput. Dent. 2020;23:343–350. [PubMed] [Google Scholar]
- 43.Park S.-M., Park J.-M., Kim S.-K., Heo S.-J., Koak J.-Y. Flexural strength of 3D-printing resin materials for provisional fixed dental prostheses. Materials. 2020;13:3970. doi: 10.3390/ma13183970. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Song S.-Y., Shin Y.-H., Lee J.-Y., Shin S.-W. Color stability of provisional restorative materials with different fabrication methods. J. Adv. Prosthodont. 2020;12:259–264. doi: 10.4047/jap.2020.12.5.259. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Yao Q., Morton D., Eckert G.J., Lin W.-S. The effect of surface treatments on the color stability of CAD-CAM interim fixed dental prostheses. J. Prosthet. Dent. 2020;126:248–253. doi: 10.1016/j.prosdent.2020.05.017. [DOI] [PubMed] [Google Scholar]
- 46.Abad-Coronel C., Carrera E., Mena Córdova N., Fajardo J.I., Aliaga P. Comparative analysis of fracture resistance between CAD/CAM materials for interim fixed prosthesis. Materials. 2021;14:7791. doi: 10.3390/ma14247791. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Myagmar G., Lee J.H., Ahn J.S., Yeo I.L., Yoon H.I., Han J.S. Wear of 3D printed and CAD/CAM milled interim resin ma-terials after chewing simulation. J. Adv. Prosthodont. 2021;13:144–151. doi: 10.4047/jap.2021.13.3.144. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Taşın S., Ismatullaev A., Usumez A. Comparison of Surface Roughness and Color Stainability of 3-Dimensionally Printed Interim Prosthodontic Material with Conventionally Fabricated and CAD-CAM Milled Materials. J. Prosthet. Dent. 2021. in press . [DOI] [PubMed]
- 49.Revilla-León M., Morillo J.A., Att W., Özcan M. Chemical composition, knoop hardness, surface roughness, and adhesion aspects of additively manufactured dental interim materials. J. Prosthodont. 2021;30:698–705. doi: 10.1111/jopr.13302. [DOI] [PubMed] [Google Scholar]
- 50.Mayer J., Stawarczyk B., Vogt K., Hickel R., Edelhoff D., Reymus M. Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material. Clin. Oral Investig. 2021;25:5987–5996. doi: 10.1007/s00784-021-03905-9. [DOI] [PubMed] [Google Scholar]
- 51.Henderson J.Y., Korioth T.V., Tantbirojn D., Versluis A. Failure load of milled, 3D-printed, and conventional chairside-dispensed interim 3-unit fixed dental prostheses. J. Prosthet. Dent. 2022;127:275.e1–275.e7. doi: 10.1016/j.prosdent.2021.11.005. [DOI] [PubMed] [Google Scholar]
- 52.Martín-Ortega N., Sallorenzo A., Casajús J., Cervera A., Revilla-León M., Gómez-Polo M. Fracture resistance of additive manufactured and milled implant-supported interim crowns. J. Prosthet. Dent. 2022;127:267–274. doi: 10.1016/j.prosdent.2020.11.017. [DOI] [PubMed] [Google Scholar]
- 53.Simoneti D.M., Pereira-Cenci T., Dos Santos M. Comparison of material properties and biofilm formation in interim single crowns obtained by 3D printing and conventional methods. J. Prosthet. Dent. 2022;127:168–172. doi: 10.1016/j.prosdent.2020.06.026. [DOI] [PubMed] [Google Scholar]
- 54.Baldi A., Comba A., Tempesta R.M., Carossa M., Pereira G.K.R., Valandro L.F., Paolone G., Vichi A., Goracci C., Scotti N. External marginal gap variation and residual fracture resistance of composite and lithium-silicate CAD/CAM overlays after cyclic fatigue over endodontically-treated molars. Polymers. 2021;13:3002. doi: 10.3390/polym13173002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Duarte S., Sartori N., Phark J.-H. Ceramic-reinforced polymers: CAD/CAM hybrid restorative materials. Curr. Oral Health Rep. 2016;3:198–202. doi: 10.1007/s40496-016-0102-2. [DOI] [Google Scholar]
- 56.Engler M.L.P.D., Güth J.F., Keul C., Erdelt K., Edelhoff D., Liebermann A. Residual monomer elution from different con-ventional and CAD/CAM dental polymers during artificial aging. Clin. Oral Investig. 2020;24:277–284. doi: 10.1007/s00784-019-02947-4. [DOI] [PubMed] [Google Scholar]
- 57.Balkenhol M., Knapp M., Ferger P., Heun U., Wöstmann B. Correlation between polymerization shrinkage and marginal fit of temporary crowns. Dent. Mater. 2008;24:1575–1584. doi: 10.1016/j.dental.2008.07.001. [DOI] [PubMed] [Google Scholar]
- 58.Köroğlu A., Sahin O., Dede D., Yilmaz B. Effect of different surface treatment methods on the surface roughness and color stability of interim prosthodontic materials. J. Prosthet. Dent. 2016;115:447–455. doi: 10.1016/j.prosdent.2015.10.005. [DOI] [PubMed] [Google Scholar]
- 59.Sahin O., Dede D.Ö., Köroğlu A., Yılmaz B. Influence of surface sealant agents on the surface roughness and color stability of artificial teeth. J. Prosthet. Dent. 2015;114:130–137. doi: 10.1016/j.prosdent.2015.02.009. [DOI] [PubMed] [Google Scholar]
- 60.Doray P.G., Eldiwany M.S., Powers J.M. Effect of resin surface sealers on improvement of stain resistance for a composite provisional material. J. Esthet. Restor. Dent. 2003;15:244–250. doi: 10.1111/j.1708-8240.2003.tb00292.x. [DOI] [PubMed] [Google Scholar]
- 61.Sarac D., Sarac Y.S., Kulunk S., Ural C., Kulunk T. The effect of polishing techniques on the surface roughness and color change of composite resins. J. Prosthet. Dent. 2006;96:33–40. doi: 10.1016/j.prosdent.2006.04.012. [DOI] [PubMed] [Google Scholar]
- 62.Iazzetti G., Burgess J.O., Gardiner D., Ripps A. Color stability of fluoride-containing restorative materials. Oper. Dent. 2000;25:520–525. [PubMed] [Google Scholar]
- 63.Hersek N., Canay S., Uzun G., Yildiz F. Color stability of denture base acrylic resins in three food colorants. J. Prosthet. Dent. 1999;81:375–379. doi: 10.1016/S0022-3913(99)80001-8. [DOI] [PubMed] [Google Scholar]
- 64.Arima T., Murata H., Hamada T. Properties of highly cross-linked autopolymerizing reline acrylic resins. J. Prosthet. Dent. 1995;73:55–59. doi: 10.1016/S0022-3913(05)80273-2. [DOI] [PubMed] [Google Scholar]
- 65.Arima T., Murata H., Hamada T. Analysis of composition and structure of hard autopolymerizing reline resins. J. Oral Rehabil. 1996;23:346–352. doi: 10.1111/j.1365-2842.1996.tb00863.x. [DOI] [PubMed] [Google Scholar]
- 66.Ren J., Lin H., Huang Q., Zheng G. Determining color difference thresholds in denture base acrylic resin. J. Prosthet. Dent. 2015;114:702–708. doi: 10.1016/j.prosdent.2015.06.009. [DOI] [PubMed] [Google Scholar]
- 67.Figuerôa R.M.S., Conterno B., Arrais C.A.G., Sugio C.Y.C., Urban V.M., Neppelenbroek K. Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave. J. Appl. Oral Sci. 2018;26:e20170383. doi: 10.1590/1678-7757-2017-0383. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Berli C., Thieringer F.M., Sharma N., Müller J.A., Dedem P., Fischer J., Rohr N. Comparing the mechanical properties of pressed, milled, and 3D-printed resins for occlusal devices. J. Prosthet. Dent. 2020;124:780–786. doi: 10.1016/j.prosdent.2019.10.024. [DOI] [PubMed] [Google Scholar]
- 69.Gad M.M., Alshehri S.Z., Alhamid S.A., Albarrak A., Khan S.Q., Alshahrani F.A., Alqarawi F.K. Water sorption, solubility, and translucency of 3D-printed denture base resins. Dent. J. 2022;10:42. doi: 10.3390/dj10030042. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Machado C., Rizzatti-Barbosa C.M., Gabriotti M.N., Joia F.A., Ribeiro M.C., Sousa R.L. Influence of mechanical and chemical polishing in the solubility of acrylic resins polymerized by microwave irradiation and conventional water bath. Dent. Mater. 2004;20:565–569. doi: 10.1016/j.dental.2003.09.001. [DOI] [PubMed] [Google Scholar]
- 71.Perea-Lowery L., Gibreel M., Vallittu P.K., Lassila L.V. 3D-printed vs. heat-polymerizing and autopolymerizing denture base acrylic resins. Materials. 2021;14:5781. doi: 10.3390/ma14195781. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 72.Gad M.M., Fouda S.M., Abualsaud R., Alshahrani F.A., Al-Thobity A.M., Khan S.Q., Akhtar S., Ateeq I.S., Helal M.A., Al-Harbi F.A., et al. Strength and surface properties of a 3D-printed denture base polymer. J. Prosthodont. 2021;31:412–418. doi: 10.1111/jopr.13413. [DOI] [PubMed] [Google Scholar]
- 73.Alharbi N., Osman R.B., Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete cov-erage interim dental restorations. J. Prosthet. Dent. 2016;115:760–767. doi: 10.1016/j.prosdent.2015.12.002. [DOI] [PubMed] [Google Scholar]
- 74.Curran P., Cattani-Lorente M., Wiskott H.A., Durual S., Scherrer S.S. Grinding damage assessment for CAD-CAM restorative materials. Dent. Mater. 2017;33:294–308. doi: 10.1016/j.dental.2016.12.004. [DOI] [PubMed] [Google Scholar]
- 75.Hazeveld A., Slater J.J.H., Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am. J. Orthod. Dentofac. Orthop. 2014;145:108–115. doi: 10.1016/j.ajodo.2013.05.011. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.