Abstract
Accurate localization of central nervous system (CNS) drug distribution in the brain is quite challenging to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI), owing to the ionization competition/suppression of highly abundant endogenous biomolecules and MALDI matrix. Herein, we developed a highly efficient sample preparation technique, laser-assisted chemical transfer (LACT), to enhance the detection sensitivity of CNS drugs in brain tissues. A focused diode laser source transilluminated the tissue slide coated with α-cyano-4-hydroxycinnamic acid, an optimal matrix to highly absorb the laser radiation at 405 nm, and a very thin-layer chemical film mainly containing drug molecule was transferred to the acceptor glass slide. Subsequently, MALDI MSI was performed on the chemical film without additional sample treatment. One major advantage of LACT is to minimize ionization competition/suppression from the tissue itself by removing abundant endogenous lipid and protein components. The superior performance of LACT led to the successful visualization of regional distribution patterns of 16 CNS drugs in the mouse brain. Furthermore, the dynamic spatial changes of risperidone and its metabolite were visualized over a 24-h period. Also, the brain-to-plasma (B/P) ratio could be obtained according to MALDI MSI results, providing an alternative means to assess brain penetration in drug discovery.
KEY WORDS: Pharmaceutical analysis, Laser-assisted chemical transfer, Mass spectrometry imaging, Drug distribution, Brain penetration
Graphical abstract
A laser-assisted chemical transfer (LACT) technique has been developed for MALDI MS imaging of CNS drug distribution in brain tissue.
1. Introduction
The total cost of drug development has more than doubled in the past decade with a high failure rate1. Particularly, brain drug development has proven to be very difficult, for example, the failure rate of Alzheimer's disease (AD) drug development was near 99.6%, which may hit investor confidence in innovation2. For central nervous system (CNS) drug discovery, one of the fundamental principles is to cross the blood‒brain barrier (BBB) and distribute at the target-site at sufficient concentration to execute its pharmacological effect3. Several approaches have been developed for mapping brain regional distribution of small molecule drugs and assessing their brain penetration in CNS drug discovery4. However, accurately mapping the spatial distribution of a drug or drug candidate in the brain is not always easy, maybe even worse for micro or trace amounts of drug metabolites. Liquid/gas chromatography‒mass spectrometry (LC/GC–MS) and ligand binding assay (e.g., ELISA) are often used for quantitative analysis of target molecules in the biological sample5, whereas the tissue homogenization is required resulting in the loss of spatial resolution. Whole-body autoradiography (WBA), positron emission tomography (PET), and fluorescence imaging offer the ability to visualize the tissue-specific distribution of drugs6,7. However, these molecular imaging techniques rely on radiolabeled tracer or report probe, which is unable to distinguish parent drug from its metabolites because only the labeled compounds can be detected7. Furthermore, the risk of label loss may occur in the metabolic process. Therefore, continuous development of imaging methods for precisely visualizing the distribution of small molecule drugs and their metabolites in brain tissues is critical to the research and development of CNS drugs, and non-CNS therapies, where brain penetration can cause unexpected CNS-mediated side effects4.
Mass spectrometry imaging (MSI) appears to be a promising label-free imaging technique for interrogating the spatiotemporal distribution of endogenous compounds in various samples8,9. The most frequently used MSI modality is matrix-assisted laser desorption/ionization (MALDI), which has been employed to map the tissue-specific distribution of small metabolites, lipids, peptides, and proteins10, 11, 12. Currently, one of the most attractive applications of MALDI MSI is the visualization of tissue distribution of drug or drug candidates and their potential metabolites, providing essential spatial information for optimizing drug ADME properties13. However, unlike LC/GC–MS, the traditional sample purification, concentration, and chromatographic separation are not available for MSI, in situ detection of small molecule drugs in tissue is greatly limited by ionization competition/suppression of highly abundant endogenous biomolecules and MALDI matrix14. Furthermore, the amount of drug in a laser spot (∼100 μm) on a 12 μm thick tissue is significantly low (∼1 pg/spot)15. If the drug delivery were limited by BBB or nonspecifically and specifically bound with protein/lipid in tissue, the situation would be worse. This may be that the spatial distribution information of drug metabolite is often missed in the MSI of the parent drug.
To overcome these limitations, various strategies have been proposed for MALDI MSI of drugs to improve detection sensitivity and specificity. Discovery of novel organic matrices with high desorption/ionization (DI) of the analyte, synthesis of diverse nanomaterials, and nanostructured surfaces with low background noise and high DI efficiency have been intensively employed16,17. Another option to minimize salts- and lipids-induced ion suppression is tissue pretreatment with a pH-controlled buffer solution or solid hydrogel prior to MALDI MSI18, 19, 20. On-tissue derivatization via the introduction of the ionized group on target drug is also utilized to improve detection sensitivity in MALDI MSI21,22. Although several MALDI MSI methods are successfully developed based on the physicochemical properties of individual drugs, the lack of universality largely hindered their broad application to the pharmaceutical industry.
It is well-known that the detection sensitivity of drug molecules could greatly increase by extracting them from complex samples to remove the ion suppression from endogenous components. However, the in situ extraction method for MALDI MSI is rarely reported and quite challenging. To achieve this goal, the laser-assisted chemical transfer (LACT) technique was introduced to extract the drug molecule in situ from the tissue without the damage of its spatial distribution. A rationally selected MALDI matrix able to absorb the laser radiation at operational wavelength was applied as the intermediate layer to drive in situ extraction and chemical transfer of the target drug molecules from tissue. LACT is a chemical transfer of exogenous components, enabling universal enhancement of MALDI detection sensitivity and visualization of the spatial distribution of CNS drug and its metabolite in brain tissue.
2. Results and discussion
The prototype LACT was designed inspired by laser-assisted transfer technique23, such as infrared laser ablation sample transfer method24 and laser-capture microdissection technology25. However, they are tissue transfer methods, an indiscriminate transfer, which cannot on-tissue separate target drug molecules from endogenous components. As shown in Fig. 1A and Supporting Information Fig. S1, LACT employs a focused laser to illuminate the matrix-coated tissue placed on a donor slide in a transmission mode, and a thin film was transferred to another clean acceptor slide. The transfer is forced by strongly localized heat during laser illumination, resulting in a small volume of materials to be ablated from tissue and deposited onto the acceptor slide. LACT relies on the efficient absorption of laser energy in the tissue to obtain the optimal pattern and chemical transfer. Therefore, it is crucial to utilize a compound able to absorb laser radiation at an operational wavelength to assist chemical transfer, not tissue transfer. Ideally, if a MALDI matrix served both absorbing compounds for LACT and matrix for subsequent MALDI MSI, it could simplify the whole experiment and avoid introducing the new chemicals. Moreover, in LACT, an electric field-assisted sprayer was assembled and used to homogenously deposit matrix solution. As proved in our previous work, compared with the conventional gas spray coating method, a micro-extraction could be induced by the electric field to facilitate the analyte moving from the tissue to the matrix layer26,27. A desirable matrix should have a low ablation threshold and high absorption coefficient, which can effectively avoid excessive thermal effects and phase changes on tissue28. Therefore, the mouse after dosing of venlafaxine was sacrificed and the brain section was sprayed with five often used matrices including DHAP, THAP, DAN, DHB, and CHCA to screen the suitable matrix for LACT. A diode laser source operated at the wavelength of 405 nm was assembled on the LACT device. The solid-state absorption spectra of five candidate matrices were acquired in the range of 350–600 nm. Among them, CHCA exhibits the highest absorption at 405 nm (Fig. 1B). As expected, the lowest energy threshold for chemical transfer was 4 mW when CHCA was applied (Fig. 1C). Although tissue sections coated with the other four matrices could be transferred using a 405 nm laser (Fig. 1D), the venlafaxine could be detected with the highest sensitivity by using CHCA-LACT (Fig. 1C and D). Herein, the optimal matching between CHCA and 405 nm laser resulted in the requirement of minimum transfer energy and greatly minimized the risk of laser-induced thermal damage. In addition, the signal intensity of venlafaxine is inversely proportional to the thickness of the transferred film (Supporting Information Fig. S2). The thinnest film (∼1 μm) could be achieved using 4 mW laser radiation with the highest signal intensity of venlafaxine (Fig. S2A). Increasing laser radiation above 16 mW, the signal intensity of venlafaxine largely decreases, and the spatial distribution pattern is hardly resolved. Additionally, to remove doubt regarding the analyte delocalization possibly caused by LACT, mouse brain dosed with a fluorescent dye was firstly imaged with fluorescence microscopy, and LACT treatment was subsequently performed for MALDI MSI at 200 μm raster step size to visualize the spatial distribution of fluorescein (m/z 333.11). As shown in Supporting Information Fig. S3A, the spatial distribution pattern of fluorescent dye obtained by using two techniques was consistent with each other, indicating that no significant compound delocalization occurred during the LACT process. Subsequently, the raster step size of 50 μm was applied to evaluate the possible compound delocalization. The fine distribution pattern of fluorescein was resolved, which was in a blood vessel with a diameter of ∼50 μm, consistent with the fluorescence image (Fig. S3A). Furthermore, brain tissues from animals dosed with imipramine were subjected to LACT for MALDI MSI of its distribution in the cerebellum (Fig. S3B). Compared to the H&E-stained image, the ion image of imipramine acquired at 50 μm step size by MALDI MSI could resolve the stripe interval between cerebellar folium (∼100 μm) and the morphology of the granular layer and white matter. Additionally, a comparison of ion images of selected lipids obtained at 200 μm step size was performed on brain tissues treated with and without LACT, respectively. As shown in Fig. S3C, similar spatial distribution patterns of two selected lipids were obtained. Therefore, LACT could well preserve the spatial distribution of compound and could not cause the significant delocalization of the analytes. It can reflect the intrinsic and real distribution of molecules in tissue.
To further explore the underlying reason for the enhancement of the signal intensity of the drug by using CHCA-LACT, the potential discrimination effect in tissue transfer was investigated. LC‒MS/MS analysis was performed on untreated and LACT treated tissue sections of the venlafaxine-dosed mouse brain, respectively, showing that approximately 21% of venlafaxine was extracted from the tissue and transferred to chemical film (Supporting Information Fig. S4). Moreover, the amounts of total lipids and proteins in the chemical film were determined by using sulfo-phospho-vanillin (SPV) and bicinchoninic acid (BCA) assays, respectively. As shown in Supporting Information Figs. S5 and S6, significant decreases in total lipids (64%, P < 0.001) and total proteins (97%, P < 0.001) were observed after LACT treatment. Several studies have proved that lipids and proteins could cause severe ion suppression of small molecules29,30. Therefore, LACT could achieve an in situ extraction and strips out matrix-analyte cocrystals from the tissue to separate endogenous and exogenous components. The enhancement of detection sensitivity provided by LACT was mainly attributed to the purification of the matrix-tissue layer by discarding the tissue proteins and lipids. Consequently, ionization competition and suppression from the tissue itself was greatly minimized, which was beneficial for the detection of exogenous compounds.
Moreover, the mixture solution of CNS drug and CHCA was homogenously spray-coated on the bare ITO slide and brain tissue to evaluate tissue extinction coefficient (TEC), which is used to account for ion suppression effects that occurred in MALDI MSI14. TEC is calculated by comparing the mean signal intensity of a standard obtained from the tissue and bare ITO slide. The strong signal intensity of venlafaxine was obtained from bare ITO slide and chemical film, however, the venlafaxine signal was markedly suppressed by untreated brain tissue (Fig. 2A). Similar results were observed for other 15 test CNS drugs (Supporting Information Fig. S7). As shown in Fig. 2B, the average TEC value for untreated tissues of 16 CNS drugs was 0.045, similar to previous reports14,31. However, the average TEC value for chemical films of 16 CNS drugs was 0.76, having a ∼17-fold increase. TEC results suggested that the ion suppression is mainly derived from the tissue itself, and CHCA-LACT can provide a universal enhancement effect for selected CNS drugs.
Finally, the performance of the CHCA-LACT was evaluated for its sensitivity and linearity. As shown in Fig. 2C and Supporting Information Fig. S8, >1300-fold decrease in the limit of detection (LOD) of 16 CNS drugs was observed in the chemical films as compared to the untreated tissue. Therefore, the CHCA-LACT technique can significantly improve the MALDI MS detection sensitivity of various CNS drugs due to the global minimization of ionization competition/suppression effect from abundant components in tissue. To evaluate the linearity of the method, serial dilutions of venlafaxine and lamotrigine were manually spotted on the cortex of the blank brain tissue section, respectively, and LACT was subsequently performed. The calibration curve was generated for venlafaxine and lamotrigine by plotting average signal intensities of mass spectra in a defined region of interest (ROI) as a function of the concentration of standards spotted on the brain tissue section (Supporting Information Fig. S9). The MALDI MSI results exhibited ideal linearity (R = 0.9953 for venlafaxine and R = 0.9925 for lamotrigine) within the 100-fold concentration range.
The utility of CHCA-LACT was comprehensively demonstrated by MALDI MSI of 16 CNS drugs (including 6 antipsychotic drugs, 2 anesthetic drugs, 3 antidepressant drugs, 1 antiepileptic drug, 3 anti-Alzheimer drugs, and 1 antihypertensive drug) in brain tissues from mice receiving a single dose. Meanwhile, a comparison of CHCA-LACT with the other three methods (MALDI with CHCA, MALDI with DHB, and blank control) was performed to show the advantage of CHCA-LACT in the high detection sensitivity (Fig. 3). The blank tissue treated by CHCA-LACT was used to eliminate false positive. In situ tandem MS/MS was performed on dosed tissues treated by CHCA-LACT to validate the identity of the drug (Supporting Information Fig. S10 and Table S2). Undoubtedly, most CNS drugs were not detectable by conventional CHCA and DHB matrices, and no interference peak was observed in blank tissue. However, with the aid of CHCA-LACT, the brain regional distributions of 16 CNS drugs were successfully revealed in the horizontal sections of the mouse brains after i.p. dosing, showing the similarity and difference in spatial distribution. Relatively high levels of drugs were detected in the cerebral cortex followed by the hippocampus, thalamus, and striatum, generally in agreement with previous studies20,32. Distinct distribution patterns were visualized for specific drugs. For example, quite low levels of venlafaxine, fluoxetine, and lamotrigine were observed in the cerebellum as compared with the cortex and the rest of the brain regions, which were confirmed by previous HPLC and autoradiographic methods33, 34, 35. These results indicate that the CHCA-LACT technique provides a universal enhancement of signal intensities of CNS drugs enable to achieve the accurate tissue-specific distributions of drugs in brain tissue. It is a very useful alternative means when the traditional MALDI MSI does not work.
The superior performance of CHCA-LACT was further demonstrated by interrogation of spatiotemporal changes of antipsychotic drug risperidone (RISP) and its metabolite in 24 h after single dosing. RISP and its one major pharmacologically active metabolite 9-hydroxy-risperidone (9-OH RISP) were readily detected by using MALDI MS with CHCA-LACT, and their spatiotemporal changes were unraveled for the first time (Fig. 4). After i.p. administration, the drug rapidly penetrated through the BBB into the brain, reaching maximum concentration (Tmax) in ∼15 min, and it was mainly observed in the frontal cortex, striatum, and hippocampus regions colocalized with the 5-HT and dopamine receptors36. Subsequently, tissue concentration and distribution of RISP rapidly declined by 0.5 h from peak concentration, and a small amount of parent drug was only observed in the lateral ventricles after 2 h (Fig. 4A). However, 9-OH RISP reached Tmax in 1 h and was spatially confined in the lateral ventricles as shown in Fig. 4B. As expected, the BBB permeability of hydroxylated metabolite is lower than its parent drug. Repeatability measurements of spatiotemporal changes of RISP and 9-OH RISP in dosed mice were conducted with three biological and technical replicates (Supporting Information Fig. S11). We further validated these results by using LC‒MS/MS analysis on punched tissue homogenate (Fig. 4C and D). MALDI MS and LC‒MS/MS results showed a good agreement with each other in terms of brain regional concentration–time profiles and signal intensity distributions (Fig. 4D and Supporting Information Fig. S12). This experiment illustrates that MALDI MSI with CHCA-LACT provides a powerful means to accurately address the problem of tissue distribution of the drug and its metabolites. Spatiotemporal information obtained here can improve our understanding of pharmacokinetics (PK), pharmacodynamics (PD), and potential transient toxicities of RISP and its metabolite in the brain.
The extended application was finally explored by assessment of drug brain penetration to illustrate the versatility of CHCA-LACT. Brain-to-plasma (B/P) ratio, vital data for successful CNS drug development, was applied to evaluate the extent of brain uptake of 10 known CNS drugs. Taking clozapine and tacrine for example, the ion signal of plasma heme B (m/z 616.2) was utilized to segregate ion images of drugs into the brain parenchyma region and blood vessel individually (Supporting Information Figs. S13A and B). The B/P ratio was directly calculated by comparing average MS signal intensities of drugs in the brain parenchyma region to that of brain blood vessels (Fig. S13C). To validate our results, a correlation of the B/P ratio determined by MALDI MSI with CHCA-LACT and parallel artificial membrane permeability assay (PAMPA)-BBB data from literature was performed (Fig. S13D)37,38. As shown in Fig. S13E, the B/P ratio obtained by MALDI MSI correlated strongly with PAMPA-BBB data, with a correlation coefficient of R = 0.8917 and P = 0.0005 for 10 CNS drugs, demonstrating that MALDI MSI with CHCA-LACT could be an attractive tool for assessing brain penetration of potential CNS drug candidate.
3. Conclusions
Our work provides an efficient sample preparation technique to overcome the limitations of the current MALDI MSI. The results proved that CHCA-LACT is a powerful and universally applicable technique, which enables unraveling the spatiotemporal distribution of drugs and their metabolite in brain tissue, as well as assessing drug penetration in the brain.
Acknowledgments
This work was supported by the National Natural Science Foundation of China (Nos. 81973703 and 81803957), and the Natural Science Foundation of Jiangsu Province (No. BK20180567, China). The content is solely the responsibility of the authors and does not necessarily represent the official views of the funding agencies.
Footnotes
Peer review under responsibility of Chinese Pharmaceutical Association and Institute of Materia Medica, Chinese Academy of Medical Sciences
Supporting information to this article can be found online at https://doi.org/10.1016/j.apsb.2021.11.007.
Author contributions
Shuai Guo and Bin Li: conceptualisation, investigation, methodology, validation, and writing-original draft; Kening Li and Yanwen Chen: methodology and validation; Bin Li: conceptualisation, supervision, and writing-reviewing and editing.
Conflicts of interest
The authors declare no conflict of interest.
Appendix A. Supporting information
The following is the Supplementary data to this article:
References
- 1.Mullard A. New drugs cost US $2.6 billion to develop. Nat Rev Drug Discov. 2014;13:877. [Google Scholar]
- 2.Cummings J.L., Morstorf T., Zhong K. Alzheimer's disease drug-development pipeline: few candidates, frequent failures. Alzheimer's Res Ther. 2014;6:1–7. doi: 10.1186/alzrt269. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Morgan P., Brown D.G., Lennard S., Anderton M.J., Barrett J.C., Eriksson U., et al. Impact of a five-dimensional framework on R&D productivity at AstraZeneca. Nat Rev Drug Discov. 2018;17:167. doi: 10.1038/nrd.2017.244. [DOI] [PubMed] [Google Scholar]
- 4.Di L., Kerns E.H., Carter G.T. Strategies to assess blood–brain barrier penetration. Expet Opin Drug Discov. 2008;3:677–687. doi: 10.1517/17460441.3.6.677. [DOI] [PubMed] [Google Scholar]
- 5.Wong A.L.A., Xiang X., Ong P.S., Mitchell E.Q.Y., Syn N., Wee I., et al. A review on liquid chromatography-tandem mass spectrometry methods for rapid quantification of oncology drugs. Pharmaceutics. 2018;10:221. doi: 10.3390/pharmaceutics10040221. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.McEwen A., Henson C. Quantitative whole-body autoradiography: past, present and future. Bioanalysis. 2015;7:557–568. doi: 10.4155/bio.15.9. [DOI] [PubMed] [Google Scholar]
- 7.James M.L., Gambhir S.S. A molecular imaging primer: modalities, imaging agents, and applications. Physiol Rev. 2012;92:897–965. doi: 10.1152/physrev.00049.2010. [DOI] [PubMed] [Google Scholar]
- 8.Chughtai K., Heeren R.M. Mass spectrometric imaging for biomedical tissue analysis. Chem Rev. 2010;110:3237–3277. doi: 10.1021/cr100012c. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Li B., Dunham S.J.B., Dong Y., Yoon S., Zeng M., Sweedler J.V. Analytical capabilities of mass spectrometry imaging and its potential applications in food science. Trends Food Sci Technol. 2016;47:50–63. [Google Scholar]
- 10.Steuer A.E., Poetzsch M., Kraemer T. MALDI-MS drug analysis in biological samples: opportunities and challenges. Bioanalysis. 2016;8:1859–1878. doi: 10.4155/bio-2016-0158. [DOI] [PubMed] [Google Scholar]
- 11.Tang W., Gordon A., Wang F., Chen Y., Li B. Hydralazine as a versatile and universal matrix for high-molecular coverage and dual-polarity matrix-assisted laser desorption/ionization mass spectrometry imaging. Anal Chem. 2021;93:9083–9093. doi: 10.1021/acs.analchem.1c00498. [DOI] [PubMed] [Google Scholar]
- 12.Li B., Ge J., Liu W., Hu D., Li P. Unveiling spatial metabolome of Paeonia suffruticosa and Paeonia lactiflora roots using MALDI MS imaging. New Phytol. 2021;231:892–902. doi: 10.1111/nph.17393. [DOI] [PubMed] [Google Scholar]
- 13.Tang W., Chen J., Zhou J., Ge J., Zhang Y., Li P., et al. Quantitative MALDI imaging of spatial distributions and dynamic changes of tetrandrine in multiple organs of rats. Theranostics. 2019;9:932–944. doi: 10.7150/thno.30408. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Taylor A.J., Dexter A., Bunch J. Exploring ion suppression in mass spectrometry imaging of a heterogeneous tissue. Anal Chem. 2018;90:5637–5645. doi: 10.1021/acs.analchem.7b05005. [DOI] [PubMed] [Google Scholar]
- 15.Vismeh R., Waldon D.J., Teffera Y., Zhao Z. Localization and quantification of drugs in animal tissues by use of desorption electrospray ionization mass spectrometry imaging. Anal Chem. 2012;84:5439–5445. doi: 10.1021/ac3011654. [DOI] [PubMed] [Google Scholar]
- 16.Wu Q., Chu J.L., Rubakhin S.S., Gillette M.U., Sweedler J.V. Dopamine-modified TiO 2 monolith-assisted LDI MS imaging for simultaneous localization of small metabolites and lipids in mouse brain tissue with enhanced detection selectivity and sensitivity. Chem Sci. 2017;8:3926–3938. doi: 10.1039/c7sc00937b. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Stopka S.A., Rong C., Korte A.R., Yadavilli S., Nazarian J., Razunguzwa T.T., et al. Molecular imaging of biological samples on nanophotonic laser desorption ionization platforms. Angew Chem. 2016;128:4558–4562. doi: 10.1002/anie.201511691. [DOI] [PubMed] [Google Scholar]
- 18.Shariatgorji M., Kallback P., Gustavsson L., Schintu N., Svenningsson P., Goodwin R.J., et al. Controlled-pH tissue cleanup protocol for signal enhancement of small molecule drugs analyzed by MALDI-MS imaging. Anal Chem. 2012;84:4603–4607. doi: 10.1021/ac203322q. [DOI] [PubMed] [Google Scholar]
- 19.Song X., Luo Z., Li X., Li T., Wang Z., Sun C., et al. In situ hydrogel conditioning of tissue samples to enhance the drug's sensitivity in ambient mass spectrometry imaging. Anal Chem. 2017;89:6318–6323. doi: 10.1021/acs.analchem.7b00091. [DOI] [PubMed] [Google Scholar]
- 20.Chen Y., Tang W., Gordon A., Li B. Development of an integrated tissue pretreatment protocol for enhanced MALDI MS imaging of drug distribution in the brain. J Am Soc Mass Spectrom. 2020;31:1066–1073. doi: 10.1021/jasms.0c00003. [DOI] [PubMed] [Google Scholar]
- 21.Shariatgorji R., Nilsson A., Fridjonsdottir E., Strittmatter N., Dannhorn A., Svenningsson P., et al. Spatial visualization of comprehensive brain neurotransmitter systems and neuroactive substances by selective in situ chemical derivatization mass spectrometry imaging. Nat Protoc. 2021;16:3298–3321. doi: 10.1038/s41596-021-00538-w. [DOI] [PubMed] [Google Scholar]
- 22.Wu Q., Comi T.J., Li B., Rubakhin S.S., Sweedler J.V. On-tissue derivatization via electrospray deposition for matrix-assisted laser desorption/ionization mass spectrometry imaging of endogenous fatty acids in rat brain tissues. Anal Chem. 2016;88:5988–5995. doi: 10.1021/acs.analchem.6b01021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Serra P., Piqué A. Laser-induced forward transfer: fundamentals and applications. Adv Mater Technol. 2019;4:1800099. [Google Scholar]
- 24.Park S.G., Murray K.K. Infrared laser ablation sample transfer for MALDI imaging. Anal Chem. 2012;84:3240–3245. doi: 10.1021/ac3006704. [DOI] [PubMed] [Google Scholar]
- 25.Espina V., Wulfkuhle J.D., Calvert V.S., VanMeter A., Zhou W., Coukos G., et al. Laser-capture microdissection. Nat Protoc. 2006;1:586–603. doi: 10.1038/nprot.2006.85. [DOI] [PubMed] [Google Scholar]
- 26.Guo S., Wang Y., Zhou D., Li Z. Electric field-assisted matrix coating method enhances the detection of small molecule metabolites for mass spectrometry imaging. Anal Chem. 2015;87:5860–5865. doi: 10.1021/ac504761t. [DOI] [PubMed] [Google Scholar]
- 27.Wang X., Han J., Yang J., Pan J., Borchers C.H. Matrix coating assisted by an electric field (MCAEF) for enhanced tissue imaging by MALDI-MS. Chem Sci. 2015;6:729–738. doi: 10.1039/c4sc01850h. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Karnakis D., Lippert T., Ichinose N., Kawanishi S., Fukumura H. Laser induced molecular transfer using ablation of a triazeno-polymer. Appl Surf Sci. 1998;127:781–786. [Google Scholar]
- 29.Boskamp M.S., Soltwisch J. Charge distribution between different classes of glycerophospolipids in MALDI-MS imaging. Anal Chem. 2020;92:5222–5230. doi: 10.1021/acs.analchem.9b05761. [DOI] [PubMed] [Google Scholar]
- 30.Furey A., Moriarty M., Bane V., Kinsella B., Lehane M. Ion suppression; a critical review on causes, evaluation, prevention and applications. Talanta. 2013;115:104–122. doi: 10.1016/j.talanta.2013.03.048. [DOI] [PubMed] [Google Scholar]
- 31.Rzagalinski I., Kovacevic B., Hainz N., Meier C., Tschernig T., Volmer D.A. Toward higher sensitivity in quantitative MALDI imaging mass spectrometry of CNS drugs using a nonpolar matrix. Anal Chem. 2018;90:12592–12600. doi: 10.1021/acs.analchem.8b02740. [DOI] [PubMed] [Google Scholar]
- 32.Vallianatou T., Shariatgorji M., Nilsson A., Fridjonsdottir E., Kallback P., Schintu N., et al. Molecular imaging identifies age-related attenuation of acetylcholine in retrosplenial cortex in response to acetylcholinesterase inhibition. Neuropsychopharmacology. 2019;44:2091–2098. doi: 10.1038/s41386-019-0397-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Murrell M.D., Cruz D.A., Javors M.A., Thompson P.M. Distribution of venlafaxine, O-desmethylvenlafaxine, and O-desmethylvenlafaxine to venlafaxine ratio in postmortem human brain tissue. J Forensic Sci. 2014;59:683–689. doi: 10.1111/1556-4029.12393. [DOI] [PubMed] [Google Scholar]
- 34.Mukherjee J., Das M.K., Yang Z.Y., Lew R. Evaluation of the binding of the radiolabeled antidepressant drug, 18F-fluoxetine in the rodent brain: an in vitro and in vivo study. Nucl Med Biol. 1998;25:605–610. doi: 10.1016/s0969-8051(98)00043-2. [DOI] [PubMed] [Google Scholar]
- 35.Serralheiro A., Alves G., Fortuna A., Falcão A. Direct nose-to-brain delivery of lamotrigine following intranasal administration to mice. Int J Pharm. 2015;490:39–46. doi: 10.1016/j.ijpharm.2015.05.021. [DOI] [PubMed] [Google Scholar]
- 36.van Beijsterveldt L.E., Geerts R.J., Leysen J.E., Megens A.A., Van den Eynde H.M., Meuldermans W.E., et al. Regional brain distribution of risperidone and its active metabolite 9-hydroxy-risperidone in the rat. Psychopharmacology (Berl) 1994;114:53–62. doi: 10.1007/BF02245444. [DOI] [PubMed] [Google Scholar]
- 37.Di L., Kerns E.H., Fan K., McConnell O.J., Carter G.T. High throughput artificial membrane permeability assay for blood–brain barrier. Eur J Med Chem. 2003;38:223–232. doi: 10.1016/s0223-5234(03)00012-6. [DOI] [PubMed] [Google Scholar]
- 38.Di L., Kerns E.H., Bezar I.F., Petusky S.L., Huang Y. Comparison of blood–brain barrier permeability assays: in situ brain perfusion, MDR1-MDCKII and PAMPA-BBB. J Pharm Sci. 2009;98:1980–1991. doi: 10.1002/jps.21580. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.