. 2021 Dec 18;24(6):959–969. doi: 10.1093/europace/euab304

Table 2.

Procedural data

Electroanatomic mapping system, n (%)
 Carto 23 (88)
 Rhythmia 3 (12)
Pre- or periprocedural imaging, n (%)
 Intracardiac echocardiography 4/26 (15)
 Magnetic resonance imaging 4/26 (15)
 Computed tomography 1/26 (4)
Clinical VT inducible, n (%) 24 (92)
Number of inducible VT, n (inter-quartile range) 1 (1–1)
Clinical VT cycle length (ms) 385 (343–428)
Haemodynamic support, n (%)
 General anaesthesia 1 (4)
 Impella 1 (4)
Procedure duration (min) 196.5 ± 55.8
Fluoroscopy time (min) 19.5 ± 9.4
Fluoroscopy dose (cGy·cm2) 3847 ± 5613
Coronary angiography before energy application, n (%) 12 (46)
Unipolar ablation in same procedure, n (%) 15 (58)
Mean maximum applied energy during B-RFA (W) (total range) 37.5 ± 8.9 (24–50)
Acute success, n (%)
 PVC, suppression 7/12 (58)
 Clinical VT, non-inducibility 14/14 (100)
 Overall VT, non-inducibility 12/14 (86)
Periprocedural complications, n (%)
 Overall 3 (12)
 Groin complications 2 (8)
 Atrioventricular block with pre-existing ICD 1 (4)
Follow-up (n = 23 patients)
Median follow-up duration, days (inter-quartile range) 139 (75–245)
Freedom of arrhythmia, n (%)
 PVC 5/9 (56)
 VT 7/14 (50)
Re-do ablation, n (%)
 PVC 1/9 (11)
 VT 2/14 (14)

Variables expressed as n (%) or n ± standard deviation.

B-RFA, bipolar radiofrequency ablation; ICD, implantable cardioverter-defibrillator; PVC, premature ventricular contraction; VA, ventricular arrhythmia; VT, ventricular tachycardia.