Table 1.

Average plasmon wavelength (Ave pwl) of antibody−gold conjugates in various buffer conditions, with or without PEG2000 stabilization of conjugates, and at different levels of salt in the final reaction solution (NaCl). Standard Deviation (Std Dev) is based on 4 measurements.

Buffer PEG2000 NaCl (mM) Ave pwl Std Dev Condition chosen Note
H6 - - 574 ~ 600 -   Unable to obtain stable measurement due to aggregation
H6 + - 544.2 6.4   Measurable, yet broad and shallow peak
H6 + 15 532.0 0.2   Stable pwl profile, similar to that of PBS
H6 + 30 532.0 0.2 H6N30 is chosen for high throughput assay
H6 + 40 528.7 0.2    
H6 + 50 528.7 0.1    
C6 + - 530.0 0   Upon PEG2000 treatment, C6 condition does not need additional salt for stabilization
C6 + 30 529.0 0 C6N30
A5 + 30 530.0 0 A5N30
PBS - - 530.0 0    
PBS + - 530.0 0 PBS