Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2021 Nov 18;23(6):904–919. doi: 10.1111/cid.13054

Survival rates of ultra‐short (<6 mm) compared with short locking‐taper implants supporting single crowns in posterior areas: A 5‐year retrospective study

Giorgio Lombardo 1, Annarita Signoriello 1,, Mauro Marincola 2, Pietro Liboni 1, Estevam A Bonfante 3, Pier F Nocini 1
PMCID: PMC9299664  PMID: 34796619

Abstract

Background

Short and ultra‐short implants represent a predictable treatment, in terms of implant survival, with patients presenting insufficient available bone volumes. Moreover, single crown restorations represent a gold standard in terms of oral hygiene.

Purpose

The aim of this retrospective study was to evaluate implant survival, marginal bone loss, and peri‐implant complications in 333 locking‐taper short and ultra‐short implants.

Materials and Methods

Implants were placed in the maxillary and mandibular posterior regions of 142 patients. Clinical and radiographic examinations were performed at 5‐year recall appointments.

Results

All implants placed consisted of 8.0‐, 6.0‐, and 5.0‐mm length, 38.14%, 34.53%, and 27.33%, respectively. Three hundred thirty‐two implants (one early failure) were rehabilitated with single crowns in 141 patients. In 45.48% of the implants the crown‐to‐implant ratio was ≥2, with a mean value of 1.94. Overall implant‐based survival after 5 years of follow‐up was 96.10%: 96.85%, 95.65%, and 95.60% for 8.0‐, 6.0‐, and 5.0‐mm length implants, respectively (p = 0.82). Overall patient‐based survival was 91.55%. Regarding crestal bone level variations, average crestal bone loss and apical shift of the “first bone‐to‐implant contact point” position were 0.69 and 0.01 mm, respectively. Setting the threshold for excessive bone loss at 1 mm, during the time interval from loading to follow‐up, 28 implants experienced loss of supporting bone greater than 1 mm: 19 of them (67.85%) were surgically treated with a codified surgical regenerative protocol. After 60 months, a peri‐implantitis prevalence of 5.94% was reported, with an overall implant success of 94.06%: 95.93%, 92.73%, and 93.10% for 8.0‐, 6.0‐, and 5.0‐mm length implants, respectively (p = 0.55).

Conclusion

Long‐term outcomes suggest that short and ultra‐short locking‐taper implants can be successfully restored with single crowns in the posterior area of the maxilla and mandible.

Keywords: bone loss, crown‐to‐implant ratio, peri‐implantitis, short, single crown, success, survival, ultra‐short


What is known

Recent studies support the use of short (lengths ≥6 and ≤8 mm) implants as a predictable method of rehabilitation in posterior regions only if splinted. Moreover, most of the studies reported follow‐ups of less than 5 years, with the absence of a specific assessment of different types of implant design.

What this study adds

This retrospective study reports promising 5‐year outcomes in terms of implants survival for short and ultra‐short implants with a plateau design, a locking‐taper implant‐abutment connection and restored with single crowns.

1. INTRODUCTION

In the last decades implant placement has become a widespread and predictable methodology of treatment for partially edentulous posterior regions. However, in some instances the long‐term absence of teeth has resulted in extensive resorption of the alveolar ridge. 1 As a consequence, there may not be a sufficient volume of bone available for standard implant rehabilitation without subjecting the patient to difficult, invasive, and costly surgical grafting procedures. 2 In these specific conditions, the placement of short (lengths ≥6 and ≤8 mm) implants 3 may represent a valid alternative therapy to augmentation procedures for maxillary and mandibular jaw atrophies. Moreover, the use of short implants reduces the number of surgeries, potential morbidity, and time and costs of the treatment. Several meta‐analyses showed no significant differences in survival rates between short and standard diameter implants. 4 , 5 , 6 , 7 With a better understanding of the mechanisms underlying osseointegration and the development of new technologies, consisting in modifications of implant surfaces 8 (through traditional methods 9 or bioactive components 10 ) and improvement of macrodesign features, 11 , 12 short implants have shown high‐quality performances.

The success of short implants has led to the development of a new class of implants, ultra‐short implants (length < 6 mm). 13 Recent meta‐analyses and systematic reviews focusing on implants with lengths ≤6 mm 14 , 15 , 16 , 17 , 18 , 19 have supported the use of these implants as a predictable method with stable results, but most of the studies reported follow‐ups of less than 5 years. Moreover, most of them combined splinted crown and single‐crown restorations 2 , 4 , 5 , 6 , 7 , 20 , 21 : the absence of a specific assessment of different types of restoration design may certainly represent a serious limitation in reaching effective conclusions regarding the survival and success of ultra‐short implants.

In a previous investigation, 22 short implants were used to restore multiple adjacent teeth loss with unsplinted single crowns, which may be suggested as a gold standard in terms of oral hygiene procedures and framework. On the other hand, the analysis of implant survival and success has been strictly connected with peri‐implant marginal bone loss, a critical issue in the case of unsplinted prosthetic rehabilitations characterized by disproportionate crown‐to‐implant ratios (CIRs). 23 Authors of the present study support the hypothesis that these issues are of particular importance in case of ultra‐short implants, as the stability of marginal bone levels appears to be of crucial importance for implant survival at the medium and long‐term follow‐ups. Despite discrepancies among different authors regarding the definitions of marginal bone loss and success criteria 22 , 24 , 25 , 26 , 27 in the evaluation of short and ultra‐short locking‐taper implants, the threshold for bone loss compatible with implant success was set at 1 mm after 5 years. This rigorous value was proposed considering that a threshold of 2 mm after a medium‐term follow‐up, even if allowable for 8‐mm length implants, cannot be considered acceptable for 6.0‐ and 5.0‐mm length implants (the shortest groups), for the involvement, in terms of marginal bone loss, of almost half of implant length.

Given the limits of previously published investigations (especially short‐term 3‐year follow‐up), and since controversial outcomes are still present in the literature for ultra‐short implants supporting single crown restorations, 5 , 28 , 29 , 30 the aim of this retrospective study was to evaluate whether the clinical and radiographic results of ultra‐short (5‐mm length) locking‐taper implants supporting single crowns are comparable to short implants (6‐ and 8‐mm length) after 5 years of follow‐up.

2. MATERIALS AND METHODS

A retrospective study with a 5‐year follow‐up was conducted in 2020 on patients who had been referred between February 2007 and June 2015, for edentulism (tooth loss caused by trauma, caries or periodontal disease) in the posterior areas of maxilla and mandible at the Dental and Maxillo‐Facial Surgery Clinic at the University of Verona. The study was approved by the University Institutional Review Board (Prot. 34 939, CROWNMAXMAND, 30/05/18). The nature and aim of the study, together with the anonymity in the scientific use of data, were clearly presented in a written informed consent form, and signed by every patient. All procedures accorded with Helsinki Declaration and good clinical practice guidelines for research on human beings.

Patients enrolled for the study matched the following inclusion criteria 22 , 31 , 32 , 33 : aged between 18 and 90 years; having had single‐tooth replacement of at least one 8.0, 6.0, or 5.0 mm locking‐taper implant supporting a single crown; had no previous consent for bone augmentation procedures; had a history of treated chronic periodontal diseases, or were never affected by any form of periodontal disease; and who were compliant with a regular maintenance program (professional oral hygiene sessions every 4 months). Exclusion criteria of the study were previously described 22 , 31 , 32 , 33 (see Appendix).

The locking‐taper (Morse taper or Morse cone) dental implant system (Bicon Dental Implants; Bicon LLC) used in this study is characterized by a convergent crest module, platform switching, plateau root‐form design, and an Integra CP surface (hydroxyapatite treated and acid‐etched). 22 , 31 , 32 , 33

All surgical treatments were conducted by a single clinician, as previously described 22 , 31 , 32 , 33 (see Appendix). After 4–6 months the implants were surgically uncovered, healing abutments were placed, and the mucosal flaps readapted around them. After 3 weeks of soft‐tissue healing, impressions were taken using a polyether material (3M ESPE Impregum Impression Material). Definitive single‐crown porcelain or composite restorations were placed within 2 weeks. The choice for restorative materials (porcelain or composite) was based on patients' preference, which was guided by personal economic resources in most of the cases (see Appendix). The technique used for the composite restorations was the Integrated Abutment Crown (IAC), in which crowns are conventionally fabricated but also extraorally cemented to the abutment, excess cement is removed and then the one‐piece abutment and crown are inserted (see Appendix). 34

Recall appointments were established to manage prosthetic complications as needed, and a maintenance program was designed to provide patients a professional oral hygiene session every 4 months. Clinical and radiographic examinations 22 , 31 , 32 , 33 were performed during the follow‐up 5 years from loading time, one time per year at regular intervals.

The postsurgery evaluations and the follow‐up evaluations were performed by two other operators both of whom were different from the clinician who performed the surgical phase.

Implant lengths considered in the study were 8.0, 6.0, and 5.0 mm; implant diameters were 3, 3.5, 4.0, 4.5, 5.0, 6.0, and 6.5 mm. Covariates included were: sex, age, smoking history, history of periodontal disease 35 (see Appendix), American Society of Anesthesiologists (ASA) status, number of oral hygiene sessions per year, use of interproximal oral hygiene devices, arch involved, tooth site, prosthetic material, CIR. 22 , 31 , 32 , 33

Study outcomes were implant survival, marginal bone loss, and implant success after 5 years of follow‐up, which were assessed according to covariates. In regard with implant survival, failure was considered as the need for implant removal either before loading (due to absence of osseointegration), or after loading (due to excessive bone loss). Implant survival was considered as the implant's state of being in function at the 5‐year follow‐up evaluation, for example, symptom‐free, without mobility, radiolucency, or bone loss so severe as to warrant implant removal. 33 , 36 , 37 , 38

A descriptive analysis was conducted between loading time and the 5‐year follow‐up time, according to covariates. This included assessment of crestal bone level (CBL; average bone level around implants at mesial and distal sides, expressed in mm), first bone‐to‐implant contact (F‐BIC; in mm) 39 , 40 , 41 with their variations ΔCBL (average bone loss) and ΔF‐BIC (average apical shift of the “first bone‐to‐implant contact point” position) (see Appendix).

Peri‐implant soft tissues were assessed using a periodontal probe (Florida Probe; Florida Probes Company) and applying a force of mild intensity (0.25 N). For each implant site, four parameters were assessed. The Modified Bleeding Index (mBI), and the Modified Plaque Index (mPLI), as reported in the literature by Mombelli, 27 were used to record the appropriate values for the mesial, central, and distal on the buccal and lingual/palatal sides of each implant. Similarly, the peri‐implant probing depths (PPD) were performed on the same six sites. The amount of keratinized tissue (KT) was assessed by measuring the distance between the zenith of the buccal gingival margin and the mucogingival line.

Biological complications after loading were also assessed at the 5‐year recall appointment. According to the latest updates, 42 peri‐implant mucositis was defined as at least one soft‐tissue peri‐implant surface with positive BOP or pus on probing, PPD ≥4 mm, and no radiographically detectable bone loss. It should be noted that visual signs of inflammation can vary and that peri‐implant mucositis can exist around implants with variable levels of bone support. 35 We diagnosed peri‐implantitis when an implant had simultaneously one surface with positive BOP or pus on probing, increasing PPD compared to previous examinations or PPD ≥5 mm in the absence of the previous examination data, and presence of radiographically detectable bone loss greater than 1 mm when compared with the loading measurements. As opposed to earlier 3‐year studies on locking‐taper implants, the threshold for bone loss at a longer follow‐up of 5 years was set at 1 mm. This was done in recognition of the fact that in the present study implant length was highly reduced compared to other longer implant types, for which a threshold of 2 mm can be considered acceptable. 35 , 42 In case of 6.0‐ and 5.0‐mm length implants, a marginal bone loss of 2 mm, representing slightly less than half of the entire implant length, appears to be underestimated after 5 years of follow‐up.

Implant success was defined according to the following criteria 43 , 44 and to the defined bone loss threshold: absence of persistent pain, dysesthesia, or paraesthesia in the implant area; absence of peri‐implant infection with or without suppuration; absence of perceptible mobility of the implant; and finally, absence of persistent peri‐implant bone resorption greater than 1 mm during the time interval from loading to 5‐year follow‐up. Once the failed implants were excluded, implant success can be considered implants without signs of peri‐implantitis.

For data collection, a database including all patients evaluated in the study was created with Microsoft Excel. All data analysis was carried out using Stata v.13.0 for Macintosh (StataCorp). The normality assumptions for continuous data were assessed by using the Shapiro–Wilk test; mean and standard deviation were reported for normally distributed data, median and interquartile range (IQR) otherwise. For categorical data, absolute frequencies, percentages and 95% confidence intervals were reported. The association between categorical variables was tested with χ 2 test; if any of the expected values was less than 5, a Fisher's exact test was performed. The comparison between the means of continuous variables in two different times was performed by using paired Student's “t”‐test or Wilcoxon matched‐pairs signed‐rank test. The comparison between the means of two different groups was performed using unpaired Student's “t”, or Wilcoxon rank‐sum test. The comparison of the means among more than two groups was done using one‐way analysis of variance, or Kruskal–Wallis equality‐of‐populations rank test. A multivariate analysis (logistic regression) was carried out to find factors associated with implant success. Significance level was set at 0.05. 22 , 31 , 32 , 33

By way of illustration, Figures 1A–D and 2A–D report some radiographic cases.

FIGURE 1.

FIGURE 1

Single implants placed in 3.4, 3.5, and 3.6 sites (5 × 6 mm, 4 × 5 mm, 5 × 5 mm): (A) Preoperative radiograph before implants placement; (B) radiograph obtained at time of loading; (C) radiograph obtained at 3‐year follow‐up; (D) radiograph obtained at 5‐year follow‐up

FIGURE 2.

FIGURE 2

Single implants placed in 2.4, 2.5, and 2.6 sites (4 × 8 mm, 4.5 × 8 mm, and 5 × 6 mm): (A) Preoperative radiograph before implants placement; (B) radiograph obtained at time of loading; (C) radiograph obtained at 3‐year follow‐up; (D) radiograph obtained at 5‐year follow‐up

3. RESULTS

3.1. Demographics

A total of 142 patients (65 men and 77 women) received at least one 8.0‐, 6.0‐, or 5.0‐mm length single‐crown dental implant. Of the patients, 78.87% (112/142) were nonsmokers, 59.15% (84/142) had an ASA status I, and 52.82% (76/142) had a history of periodontal disease. All patients were compliant with the maintenance program, receiving on average, three oral professional hygiene sessions in a year; 74.65% (106/142) of them used interproximal oral hygiene devices daily. Mean age at placement was 53.48 ± 10.39 (range 29–78) years.

Of the 333 implants placed, 127 (38.14%) were 8‐mm length, 115 (34.53%) were 6‐mm length, and 91 (27.33%) were 5‐mm length. The majority of 8‐mm length implants were placed in premolar regions, while 5‐ and 6‐mm length implants were placed in molar regions. One implant in the posterior maxilla failed before loading, thus 332 implants in 141 patients (64 men and 77 women) were finally rehabilitated with single crowns. The mean CIR was 1.94 ± 0.85 (range 0.91–3.81) and 45.48% of the implants presented a CIR ≥2. CIR in 8‐, 6‐, and 5‐mm length, respectively, was 1.45 ± 0.32 (range 0.91–3.06), 2.01 ± 0.48 (range 1.09–3.03), and 2.57 ± 0.59 (range 1.80–3.81), with statistically significant differences among groups (p < 0.001).

The implants distribution, analyzed according to length‐groups, is presented in Table 1.

TABLE 1.

Overall implants and length‐groups distribution according to study variables. Age at follow‐up and oral professional hygiene/year, respectively, are presented as mean ± standard deviation and median (IQR)

Variable Overall 5 mm 6 mm 8 mm Test statistic df p Value
Sex
Male 150 (45.05) 38 (41.76) 59 (51.30) 53 (41.73) χ 2 = 2.78 2 NS (p = 0.24)
Female 183 (54.95) 53 (58.24) 56 (48.70) 74 (58.27)
Age at follow‐up 59.57 ± 10.52 58.55 ± 9.82 60.34 ± 9.86 59.62 ± 11.56 χ 2 = 5.49 2 NS (p = 0.06)
Smoking history
No 268 (80.48) 67 (73.63) 97 (84.35) 104 (81.89) χ 2 = 3.97 2 NS (p = 0.13)
Yes 65 (19.52) 24 (26.37) 18 (15.65) 23 (18.11)
ASA status
I 159 (47.75) 47 (51.65) 53 (46.09) 59 (46.46) χ 2 = 0.76 2 NS (p = 0.68)
II 174 (52.25) 44 (48.35) 62 (53.91) 68 (53.54)
Oral professional hygiene/year 3 (2) 3 (2) 3 (2) 3 (2) F = 0.74 1/332 NS (p = 0.47)
Use of interproximal oral hygiene devices
No 75 (22.52) 20 (21.98) 29 (25.22) 26 (20.47) χ 2 = 0.80 2 NS (p = 0.67)
Yes 258 (77.48) 71 (78.02) 86 (74.78) 101 (79.53)
History of periodontal disease
No 120 (36.04) 25 (27.47) 44 (38.26) 51 (40.16) χ 2 = 4.07 2 NS (p = 0.13)
Yes 213 (63.96) 66 (72.53) 71 (61.74) 76 (59.84)
Implant tooth site
Premolar 146 (43.84) 35 (38.46) 30 (26.09) 81 (63.78) χ 2 = 36.29 2 <0.001
Molar 187 (56.16) 56 (61.54) 85 (73.91) 46 (36.22)
Arch
Posterior mandible 197 (59.16) 52 (57.14) 74 (64.35) 71 (55.91) χ 2 = 1.99 2 NS (p = 0.37)
Posterior maxilla 136 (40.84) 39 (42.86) 41 (35.65) 56 (44.09)
Implant diameter
3 mm 1 (0.30) 0 (0.00) 0 (0.00) 1 (0.79)
3.5 mm 11 (3.30) 0 (0.00) 0 (0.00) 11 (8.66) χ 2 = 173.38 6 <0.001
4 mm 81 (24.32) 43 (47.25) 1 (0.87) 37 (29.13)
4.5 mm 112 (33.63) 0 (0.00) 55 (47.83) 57 (44.88)
5 mm 109 (32.73) 30 (32.97) 58 (50.43) 21 (16.54)
6 mm 18 (5.41) 17 (18.68) 1 (0.87) 0 (0.00)
6.5 mm 1 (0.30) 1 (1.10) 0 (0.00) 0 (0.00)
Prosthetic material
Resin 47 (14.16) 14 (15.38) 18 (15.79) 15 (11.81) χ 2 = 0.93 2 NS (p = 0.62)
Porcelain 285 (85.84) 77 (84.62) 96 (84.21) 112 (88.19)
Crown‐to‐implant ratio
<2 181 (54.52) 3 (3.30) 56 (49.12) 122 (96.06) χ 2 = 195.16 2 <0.001
2–2.99 133 (40.06) 73 (80.22) 56 (49.12) 4 (3.15)
>2.99 18 (5.42) 15 (16.48) 2 (1.75) 1 (0.79)

Note: For all other variables, values are presented as n (%).

Abbreviations: ASA, American Society of Anesthesiologists; df, degrees of freedom; IQR, interquartile range; NS, not statistically significant.

3.2. Implant survival

One early failure in one patient was assessed, and 12 implants were lost and removed after functional loading in 12 different patients. The overall implant‐based survival at 60‐month follow‐up was 96.10% (320/333). Failures features are recorded in Table 2. The overall patient‐based survival was 91.55% (130/142). No association was found between survival and failure groups, and any of the covariates considered (Table 3).

TABLE 2.

Failures features

Site 16 24 24 26 34 35 35 44 45 46 46 47 17
Diameter 5 4 4 5 4.5 4 4.5 5 6 4 4.5 5 5
Length 6 5 8 6 8 5 6 8 5 5 8 6 6
Sex M F F F M F M M M F M F M
Smoking history Yes No No Yes Yes No No No No No No No No
ASA status II I I II II II I II I II I II I
Oral professional hygiene/year 3 4 2 1 2 4 2 4 3 2 4 4 4
History of periodontal disease Yes No Yes Yes Yes Yes Yes Yes Yes Yes No No No
Crown‐to‐implant ratio 2.68 2.25 1.57 1.89 1.69 2.85 1.96 1.62 2.76 3.15 1.38 2.17 /
Failure Late Late Late Late Late Late Late Late Late Late Late Late Early

Abbreviation: ASA, American Society of Anesthesiologists.

TABLE 3.

Analysis of overall implant survival according to included study covariates

Variable Survival Failure Test statistic df p Value
n (%) n (%)
Sex
Male 143 (95.33) 7 (4.67) χ 2 = 0.42 1 NS (p = 0.51)
Female 177 (96.72) 6 (3.28)
Smoking history
No 258 (96.27) 10 (3.73) χ 2 = 0.10 1 NS (p = 0.72)
Yes 62 (95.38) 3 (4.62)
ASA status
I 153 (96.23) 6 (3.77) χ 2 = 0.01 1 NS (p = 0.90)
II 167 (95.98) 7 (4.02)
History of periodontal disease
No 116 (96.67) 4 (3.33) χ 2 = 0.16 1 NS (p = 0.77)
Yes 204 (95.77) 9 (4.23)
Implant tooth site
Premolar 139 (95.21) 7 (4.79) χ 2 = 0.54 1 NS (p = 0.45)
Molar 181 (96.79) 6 (3.21)
Arch
Posterior mandible 189 (95.94) 8 (4.06) χ 2 = 0.03 1 NS (p = 0.55)
Posterior maxilla 131 (96.32) 5 (3.68)
Implant diameter
3 mm 1 (100.00) 0 (0.00)
3.5 mm 11 (100.00) 0 (0.00)
4 mm 77 (95.06) 4 (4.94) χ 2 = 1.47 6 NS (p = 0.81)
4.5 mm 109 (97.32) 3 (2.68)
5 mm 104 (95.41) 5 (4.59)
6 mm 17 (94.44) 1 (5.56)
6.5 mm 1 (100.00) 0 (0.00)
Implant length
5 mm 87 (95.60) 4 (4.40) χ 2 = 0.31 2 NS (p = 0.82)
6 mm 110 (95.65) 5 (4.35)
8 mm 123 (96.85) 4 (3.15)
Prosthetic material
Resin 45 (95.74) 2 (4.26) χ 2 = 0.06 1 NS (p = 0.68)
Porcelain 275 (96.49) 10 (3.51)
Crown‐to‐implant ratio
<2 175 (96.69) 6 (3.31) χ 2 = 0.24 2 NS (p = 0.68)
2–2.99 128 (96.24) 5 (3.76)
>2.99 17 (94.44) 1 (5.56)

Note: For all variables, values are presented as n (%).

Abbreviations: ASA, American Society of Anesthesiologists; df, degrees of freedom; NS, not statistically significant.

3.3. Marginal bone loss

CBL variations are reported in Tables 4 and 5. Overall average values of CBL at loading, CBL at 5‐year follow‐up, F‐BIC at loading, F‐BIC at 5‐year follow‐up, ΔCBL and ΔF‐BIC between loading and follow‐up were, respectively: 1.99 ± 1.19 mm, 1.15 ± 1.22 mm, 0.23 (0.66) mm, 0.29 (0.85) mm, 0.69 (1.27) mm, 0.01 (0.63) mm. A statistically significant difference was found for ΔCBL regarding history of periodontal disease and for ΔF‐BIC regarding arch (Tables 4 and 5).

TABLE 4.

Overall CBL [mm] distributions and analysis of ΔCBL [mm] according to history of periodontal disease, implant tooth type, arch, implant length, prosthetic material, and CIR

Variable CBL ΔCBL Test statistic df p Value
Loading time Follow‐up time
Mean ± SD Mean ± SD Median IQR
History of periodontal disease
No 2.26 ± 1.10 1.54 ± 1.14 0.61 0.87 Z = −2.03 0.04
Yes 1.85 ± 1.22 0.93 ± 1.21 0.74 1.54
Implant tooth type
Premolar 1.95 ± 1.30 1.10 ± 1.37 0.72 1.41 Z = 0.77 NS (p = 0.43)
Molar 2.03 ± 1.10 1.18 ± 1.10 0.67 1.22
Arch
Posterior mandible 1.93 ± 1.28 1.06 ± 1.29 0.72 1.48 Z = 0.64 NS (p = 0.51)
Posterior maxilla 2.08 ± 1.05 1.27 ± 1.11 0.67 0.89
Implant length
5 mm 1.96 ± 1.15 1.14 ± 1.21 0.64 1.54 χ 2 = 0.45 NS (p = 0.79)
6 mm 2.11 ± 1.17 1.28 ± 1.10 0.68 1.23 2
8 mm 1.92 ± 1.24 1.04 ± 1.33 0.74 1.26
Prosthetic material
Resin 1.86 ± 1.19 0.96 ± 1.20 0.74 1.20 Z = 0.27 NS (p = 0.78)
Porcelain 2.02 ± 1.19 1.18 ± 1.23 0.69 1.28
Crown‐to‐implant ratio
>2 1.88 ± 1.18 1.04 ± 1.26 0.72 1.23 χ 2 = 1.33 NS (p = 0.51)
2–2.99 2.00 ± 1.12 1.18 ± 1.08 0.65 1.32 2
>2 3.10 ± 1.29 1.99 ± 1.47 0.87 1.34

Note: CBL and its variations are presented as mean (SD) or median [IQR].

Abbreviations: CBL, crestal bone level; CIR, crown‐to‐implant ratio; df, degrees of freedom; IQR, interquartile range; NS, not statistically significant.

TABLE 5.

Overall F‐BIC [mm] distributions and analysis of ΔF‐BIC [mm] according to history of periodontal disease, implant tooth type, arch, implant length, prosthetic material, and CIR

Variable F‐BIC ΔF‐BIC Test statistic df p Value
Loading time Follow‐up time
median (IQR) median (IQR) Median IQR
History of periodontal disease
No 0.14 (0.56) 0.07 (0.70) 0.01 0.43 Z = −1.70 NS (p = 0.08)
Yes 0.25 (0.70) 0.42 (0.89) 0.09 0.79
Implant tooth type
Premolar 0.25 (0.70) 0.41 (0.95) 0.07 0.73 Z = 1.29 NS (p = 0.19)
Molar 0.21 (0.61) 0.27 (0.74) 0.01 0.50
Arch
Posterior mandible 0.28 (0.72) 0.27 (0.81) 0.01 0.59 Z = −2.03 0.04
Posterior maxilla 0.21 (0.50) 0.37 (0.92) 0.08 0.78
Implant length
5 mm 0.21 (0.58) 0.32 (0.87) 0.01 0.59 χ 2 = 3.28 NS (p = 0.19)
6 mm 0.27 (0.61) 0.24 (0.75) 0.01 0.48 2
8 mm 0.23 (0.73) 0.40 (0.88) 0.05 0.73
Prosthetic material
Resin 0.33 (0.58) 0.41 (0.95) 0.23 0.78 Z = 0.91 NS (p = 0.36)
Porcelain 0.21 (0.68) 0.29 (0.83) 0.01 0.58
Crown‐to‐implant ratio
>2 0.32 (0.72) 0.31 (0.88) 0.01 0.82 χ 2 = 3.10 NS (p = 0.21)
2–2.99 0.13 (0.53) 0.30 (0.78) 0.01 0.44
>2 0.19 (0.53) 0.01 (0.80) 0.01 0.38

Note: F‐BIC and its variations are presented as mean (SD) or median [IQR].

Abbreviations: CIR, crown‐to‐implant ratio; df, degrees of freedom; F‐BIC, first bone‐to‐implant contact; IQR, interquartile range; NS, not statistically significant.

3.4. Soft tissues conditions and implant success

Soft tissues conditions were stable at 5‐year recall appointment. Average values, expressed as median (IQR), were: 3.41 (1.27) mm for PPD, 0.87 (0.84) for mBI, 0.54 (0.7) for mPLI, and 1.84 (1.42) mm for KT, respectively.

During the time interval from loading to follow‐up, 28 implants experienced loss of supporting bone >1 mm: 19 of them (67.85%) were surgically treated with a codified protocol, which consisted in access flap surgery, concomitant chemical and mechanical decontamination (through the application of a desiccant agent and sodium bicarbonate‐based abrasive air powder) of implant surface and bone grafting. 45 Out of 19 implants, peri‐implantitis was thus successfully treated in 9 implants (47.36%), which demonstrated bone levels stability at the 5‐year follow‐up. Finally, at the 5‐year follow‐up, among 320 survived implants, 23 (7.19%) exhibited peri‐implant mucositis and 19 (5.94%) presented peri‐implantitis, for a total of 42 implants (13.13%) presenting biological complications. The overall implant‐based success at 60‐month follow‐up was 94.06% (301/320). The overall patient‐based success was 90% (117/130). Significant differences (p < 0.05) were found between groups regarding sex, ASA status, and implant diameter (Table 6).

TABLE 6.

Analysis of overall implant success according to included study covariates

Variable Success No success Test statistic df p Value
n (%) n (%)
Sex
Male 130 (90.91) 13 (9.09) χ 2 = 4.60 1 0.03
Female 171 (96.61) 6 (3.39)
Smoking history
No 241 (93.41) 17 (6.59) χ 2 = 1.01 1 NS (p = 0.54)
Yes 60 (96.77) 2 (3.23)
ASA status
I 139 (90.85) 14 (9.15) χ 2 = 5.41 1 0.03
II 162 (97.01) 5 (2.99)
History of periodontal disease
No 113 (97.41) 3 (2.59) χ 2 = 3.65 1 NS (p = 0.08)
Yes 188 (92.16) 16 (7.84)
Implant tooth site
Premolar 130 (93.53) 9 (6.47) χ 2 = 0.12 1 NS (p = 0.72)
Molar 171 (94.48) 10 (5.52)
Arch
Posterior mandible 180 (95.24) 9 (4.76) χ 2 = 1.14 1 NS (p = 0.28)
Posterior maxilla 121 (92.37) 10 (7.63)
Implant diameter
3 mm 1 (100.00) 0 (0.00)
3.5 mm 9 (81.82) 2 (18.18)
4 mm 76 (98.70) 1 (1.30) χ 2 = 23.47 6 0.01
4.5 mm 101 (92.66) 8 (7.34)
5 mm 99 (95.19) 5 (4.81)
6 mm 15 (88.24) 2 (11.76)
6.5 mm 0 (0.00) 1 (100.00)
Implant length
5 mm 81 (93.10) 6 (6.90) χ 2 = 1.26 2 NS (p = 0.55)
6 mm 102 (92.73) 8 (7.27)
8 mm 118 (95.93) 5 (4.07)
Prosthetic material
Resin 44 (97.78) 1 (2.22) χ 2 = 1.29 1 NS (p = 0.49)
Porcelain 257 (93.45) 18 (6.55)
Crown‐to‐implant ratio
<2 165 (94.29) 10 (5.71) χ 2 = 0.03 2 NS (p = 0.98)
2–2.99 120 (93.75) 8 (6.25)
>2.99 16 (94.12) 1 (5.88)

Note: For all variables, values are presented as n (%).

Abbreviations: ASA, American Society of Anesthesiologists; df, degrees of freedom; NS, not statistically significant;.

The logistic regression model (Table 7) considered sex, ASA status, diameter, and history of periodontal disease (p < 0.10) for the multivariate analysis: being male, ASA status I, and having history of periodontal disease finally showed to have an independent effect on the probability of implant success.

TABLE 7.

Analysis of overall implant success according to included study covariates

Variable Odds ratio p > |z| [95% CI]
Sex 2.91 0.04 [1.02, 8.26]
ASA status 4.07 0.01 [1.39, 11.95]
History of periodontal disease 0.24 0.03 [0.06, 0.90]
Implant diameter 0.69 0.37 [0.30, 1.54]

Note: For all variables, values are presented as n (%).

Abbreviations: ASA, American Society of Anesthesiologists; CI, confidence interval; df, degrees of freedom; NS, not statistically significant.

4. DISCUSSION

In this study, concerning implant survival outcomes and marginal bone levels changes over time, no statistical differences among 8‐, 6‐ (short), and 5‐mm length (ultra‐short) implants, supporting single crowns in the posterior maxilla and mandible, were demonstrated 5 years after loading. In the past decades, several authors supported the idea that <8 mm in length implants could be considered a valid option of treatment not only in case of splinted reconstructions but also for single‐unit restorations. 30 , 46 , 47 , 48 However, considering that most of the studies were conducted with a short (1–3 years) follow‐ups, other authors 4 recommended that these results should be interpreted with caution. It was postulated that, in case of ultra‐short single‐crown implants, the long‐term influence of higher CIRs, and increased crown heights on marginal bone loss should be carefully evaluated before endorsing the use of 6‐mm length implants with single crowns in daily clinical practice.

The most recent studies with longer follow‐ups seem to confirm the hypothesis that ultra‐short implants supporting single crowns present higher variability, lower predictability, and poorer survival rates compared to longer implants. 23 , 29 , 49 On the basis of several systematic reviews with at least 5 years of follow‐up, 6 , 15 , 19 , 50 it has been proposed that ultra‐short implants, mainly suggested in cases of low vertical bone height and when complementary surgical procedures are not favorable, should be splinted. Specific factors, mostly related to the relationship between CIR and marginal bone loss, might have played a role in declaring these indications. Even if many studies and systematic reviews 4 , 23 , 49 did not observe a negative influence of disproportionate CIR on CBL stability, an increased unfavorable CIR, according to traditional standards, is typical of rehabilitations using short and ultra‐short implants, and seems to exert a worsening of performances of these implants when supporting single crowns. 41

Even if nonsplinted crowns allow easier hygiene procedures, have a passively fitting framework, and typically have better esthetics, splinting implant crowns leads to less stress transmitted to each bone‐implant interface. 51 , 52 Finite element analysis 53 , 54 showed that the higher the CIR, the higher the tension in the bone profile adjacent to the most cervical part of the implants. In presence of high lateral masticatory forces 52 a single crown may act as a lever transferring stress along the cortical bone surrounding the implant. 55 This may result in gradual crestal bone loss, which, in the in case of ultra‐short implants, may culminate in premature bone loss.

Malchiodi et al., 39 in a 3‐year prospective study on splinted and single ultra‐short implants, concluded that, above certain limits, there is a statistical correlation between CIR and crestal bone loss. This suggests the existence of specific threshold values for CIR to avoid excessive tension at the abutment‐bone interface. Rossi et al., 49 in a prospective study on thirty 10‐mm length and thirty 6‐mm length implants, found a survival rate of 96.7% and 86.7% after 5 years, with an anatomical CIR of 1.4 and 1.75. Naenni et al., 29 after 5 years of follow‐up, reported for forty‐seven 6.0‐mm length and forty‐seven 10‐mm length implants, showed a median CIR of 1.75 and 1.4, and an implant survival of 86.7% and 100%, respectively. Villarinho et al., 23 in a prospective study with a 5‐year follow‐up, found a survival rate of only 91.3% for 46 single crowns in 6‐mm length implants with a CIR of 1.66. In the present study, after 5 years of loading, a hundred and ten 6‐mm length, and eighty‐seven 5‐mm length locking‐taper implants, with an average CIR of 2.01 and 2.57, had a cumulative survival rate of 95.65%, and 95.6%, respectively. In particular, the majority of 5‐mm length implants had a CIR >2 (80.22%), while the 16.48% had a CIR even >3. Nevertheless, after 5 years, no statistically significant differences were recorded for average marginal bone levels changes among 5 mm ultra‐short and 6 mm, and 8 mm short implants; those values were 0.64 mm, 0.68 and 0.74 mm, respectively.

As implied in the discussion of the literature above, previous studies, particularly regarding disproportionate CIR in 5‐mm length implants 39 , 56 , 57 , 58 , 59 do not allow for definitive conclusions. In part this is due to the mixing of splinted and nonsplinted restorations as well as abbreviated follow‐up periods. Whereas in the present study the macrodesign of the implant system, presenting plateaus and healing chambers, have shown to increase the implant surface area (mm2) in bone, when compared to implants of similar dimensions but with screw root form macrodesign, eventually corroborating the use of 5‐mm length ultra‐short implants supporting single crowns within the range of CIR investigated herein. 60 In addition, such macrodesign presents a double platform switch that was shown to be advantageous since it seems to load bone coronal to the implant‐abutment interface (IAI) through the base of the abutment. In this platform design, an implant shoulder gradually slopes inward and coronally, toward the IAI, creating space for crestal bone, while the base of the implant abutment presents as a loading surface through which compressive loads are exerted on existing or potential crestal bone. 61 This specific feature can provide favorable considerations for single crown restorations, overcoming the previously described limits in terms of stress distribution in case of high CIR: vertical, horizontal, and rotational forces are adequately transmitted, providing stable functioning over time. 33

Furthermore, this hypothesis is supported as follows from the data presented in literature from other studies on the same type of implant. Schulte et al., 62 after an average time of 2.3 years of follow‐up (0.1–7.4 years), recorded a survival rate of 98.2% for 889 single‐tooth locking‐taper implants; CIR values for short or ultra‐short implants ranged from 0.5:1 to 3:1; the average CIR for implants in function was 1.3; the average CIR for failed implants was 1.4; authors concluded that there was no clinically significant difference between groups regarding CIR. Urdaneta et al., 40 evaluating the effect of increased CIR on 326 short and ultrashort locking‐taper implants presenting a mean CIR of 1.6 (range 0.79–4.95), reported an implant survival of 98% after 6 years. Two retrospective studies 22 , 31 with 3 years of follow‐up, reported a survival rate of 95.12% and of 95.83%, respectively, for forty‐one and forty‐eight 5‐mm implants supporting single crown in the maxilla and in the mandible.

The promising 5‐year outcomes reported in this study for implant survival and bone levels stability—even in presence of unfavorable high CIR, may be explained also by a series of human retrieval published studies of implants with the same macrodesign, consistently showing that from initial woven bone formation at the healing chambers, further bone morphologic evolution occurs toward a Haversian‐like configuration that over time increases significantly in mechanical properties. 63 , 64 , 65 The presence of a screwless, locking‐taper implant‐abutment connection confers greater mechanical stability to the implant/crown assembly, previously shown to provide an impervious seal to microbial penetration or infiltration, 66 an absence of micromovements, or micro gaps at the IAI, which lead to minimal bone resorption. 22 , 31 , 32 , 33 In this way, adjacent bone is hardly loaded at levels that could exceed the minimum effective strain necessary for bone modeling and remodeling. A study by Chou et al. 67 reported bone density distributions similar to that of the natural tooth, which led the authors to conclude that plateau‐design implants are more suitable in preventing bone loss.

Differently from the initially mentioned studies supporting the use of splinted crowns with disproportionate CIR of short and ultra‐short implants, single restorations with distinctive features, such as plateau design, locking‐taper connection and sloping shoulder, could thus be advisable, demonstrating to preserve crestal bone.

In the present study, the analysis of overall implant success, including study covariates, showed that implant diameter may influence the success, but it has little effect on the survival of ultra‐short implants. These results are in agreement with a recent study, 68 where ultra‐short implants of different diameter did not result in significant differences in the analysis of failure from a mechanical perspective. In this study, even if different for the implant system analyzed, four implants were lost in the maxilla, and nine in the mandible, showing no statistical differences between groups. Other studies have reported no difference in failure rates regarding the arch, 69 while other authors 4 reported a higher failure rate for single crowns supported by short implants in the mandible. In contrast, other reviews 70 , 71 showed a higher incidence of loss in the maxilla.

It is well‐known in literature that standard implants survival rates may not differ between periodontal and nonperiodontal patients, while patients with a history of periodontitis may instead experience a greater number of biological complications and have a lower success rate compared to periodontally healthy patients. 33 The results of the present study seem to corroborate this finding, as no statistically different implant survival (96.67% and 95.77%) was, respectively, found between healthy patients and patients with history of periodontitis. Nevertheless, in the subgroup of participants that presented a history of chronic periodontitis (52.82%), even while undergoing intensive supportive periodontal therapy, peri‐implantitis occurred/progressed at higher rate than in periodontally healthy patients. This subgroup also had an inferior, although not significant, success rate (92.16%), compared to nonperiodontal patients (97.41%). At the moment, only few studies 26 , 33 , 72 , 73 , 74 are present in literature regarding the impact of periodontal disease on short implants survival, and even these few reported short‐term contradictory results, therefore, it is not possible to draw a definitive conclusion. At this point in time, this topic should require further analysis to clarify the influence of periodontitis on the long‐term success rate of ultra‐short implants supporting single crowns.

Regarding possible implications between periodontal conditions and other factors, it was reported that reinforced composite resin material appears to accumulate more plaque deposits than titanium resulting in at least surface mucosal inflammation of peri‐implant tissues. 75 On the other hand, other authors 76 , 77 , 78 , 79 have also reported that they found no significant differences in terms of implant survival and marginal bone loss between resin and porcelain restorations. In this study, there were no statistical differences between the two prosthetic materials in terms of implant survival and CBLs (CBL and F‐BIC). In addition to that, variables related to oral hygiene habits and professional maintenance should be considered, especially for patients with history of aggressive periodontal disease, whose compliance to strict supportive protocols 33 is fundamental for the maintenance of a sufficient level of peri‐implant health.

Comparing the results of this study with the previous similar studies on locking‐taper implants done at 3‐year follow‐up, some issues remain critical. Main limitations related to its retrospective nature, even if reduced, still consist in a nonbalanced distribution among implant length‐groups and arch‐groups, besides the University setting (single‐centre). However, a proper evaluation of clinical and radiographic conditions at a longer‐term follow‐up (5 years), as well as limiting the present analysis to single crown restorations, suggests predictability of treatments using short and ultrashort locking‐taper implants even in presence of highly disproportionate CIR.

5. CONCLUSIONS

Outcomes show stable CBLs over time, with no statistically significant differences between survival and success with short (8‐ and 6‐mm length), and ultra‐short (5‐mm length) implants. Five‐year outcomes report single‐crown restorations as a successful option in the rehabilitation of atrophic posterior jaws. Further investigations with longer follow‐up and prospective design, and with a comparison between single and splinted crowns, are necessary to validate these conclusions.

CONFLICT OF INTEREST

The authors declare no conflicts of interests.

AUTHOR CONTRIBUTIONS

Giorgio Lombardo: Concept and design, data interpretation, critical revision, and approval of article. Annarita Signoriello: Data collection and analysis, planning of statistics, drafting article. Mauro Marincola: Concept and design, data interpretation, critical revision, and approval of article. Pietro Liboni: Data collection and analysis, drafting article. Estevam A. Bonfante: Data interpretation, critical revision, and approval of article. Pier F. Nocini: Data interpretation, critical revision, and approval of article.

ACKNOWLEDGMENTS

Authors would like to thank the independent statistician Dr. Luisa Zanolla (University of Verona, Verona, Italy), who reviewed the work for statistical analysis, and Dr. Joseph Leary (Periodontal Consultant, Bicon Dental Implants, Boston, USA) who reviewed the work for English editing. Open Access Funding provided by Universita degli Studi di Verona within the CRUI‐CARE Agreement. [Correction added on 20 May 2022, after first online publication: CRUI funding statement has been added.]

APPENDIX A.

Exclusion criteria for the study were 22 , 31 , 32 , 33 : presence of active infection at an implant site; ASA status III, IV,V, and VI (according to the American Society of Anesthesiologists' classification), that is, severe systemic diseases or substantive functional limitations which contraindicated implant surgery (such as drug or alcohol abuse, uncontrolled diabetes mellitus, immunosuppression or immunodepression, severe autoimmune diseases, treatment or past treatment with intravenous amino‐bisphosphonates for metastatic bone diseases, radiotherapy to head or neck within 2 years prior to treatment, history of malignancy or chemotherapy within the previous year, treatment with oral amino‐bisphosphonates for >3 years, morbid obesity, active hepatitis, severe renal disease, severe cardiovascular conditions, recent history of myocardial infarction or transient ischemic attack); untreated periodontitis; poor oral hygiene and motivation; current pregnancy or lactation; heavy smoking (>25 cigarettes per day); severe clenching or bruxism.

FIGURE A1.

FIGURE A1

Schematic example of the references for peri‐implant bone levels measurements. (1) Implant‐abutment interface; (2) most occlusal point line; (3) crestal bone level (CBL) on the mesial side; (4) CBL on the distal side; (5) first bone‐to‐implant contact (F‐BIC) on the mesial side; (6) F‐BIC on the distal side; (7) crown length; (8) implant length

A complete clinical and radiographic evaluation (dental and periodontal status; panoramic and periapical radiograph, cone beam computed tomography) and basic periodontal treatment was performed before implant placement. A preoperative medication consisting of 2 g of Augmentin (875 mg amoxicillin + 125 mg clavulanic acid), or 1 g of Klacid (clarithromycin 500 mg) if allergic to penicillin, was given 1 h before surgery. All surgical procedures were performed under local anesthesia, using only articaine 4% with adrenaline 1:100 000 (Citocartin) or articaine 4% with adrenaline 1:100 000 (Citocartin) associated with oral sedation (Halcion 0.25 mg). 22 , 31 , 32 , 33

A full‐thickness flap was performed, and a high‐speed 2.0‐mm diameter pilot drill (with a cutting edge at the apical portion and drilling at 1100 rpm) with external saline irrigation was used to perforate the cortical plate. Final pilot drilling length was determined by measuring residual bone height and adding at least 1.0 mm to the selected implant length to allow for a subcrestal implant placement. Latch reamers presenting a 0.5 mm progressive increase in diameter were used at 50 rpm, without external irrigation to widen the osteotomy until the final implant diameter was reached. The selected implant was manually inserted into the osteotomy, a healing plug was placed in the implant well, and autogenous bone collected during the slow speed preparation of the osteotomy was used to fill the gap between the implant and the bony walls. The incisions were closed by single polyglycolic acid sutures (Vycril; ACE Surgical Supply Co.). A postoperative periapical radiograph was taken, postoperative instructions were given as well as antibiotic and analgesic prescriptions. 22 , 31 , 32 , 33

The IAC is a cementless restoration for single‐tooth implants, where the crown is extraorally chemomechanically bonded to the coronal part of a titanium alloy nonshouldered or shouldered locking‐taper abutment, reduced using carbide burs to provide for smooth surface contours and subgingival margins: in this way, the implant abutment and the crown material constitute one unit. 34 The crown is inserted into place by mean a gentle tapping using a 250‐g mallet, by mean a crown seating tip supplied by the manufacturer and a custom‐made acrylic tapping jig to ensure accurate proper seating.

When composite material was preferred for the crown, a microhybrid composite containing 73% by weight microfine ceramic particles, embedded in an organic polymer matrix (Ceramage; Shofu Inc.), was used. In case of choice of ceramic material, a bilayer crown was planned using a zirconia framework veneered with feldspar ceramic (Ceramica Natural ZiR; Tressis Italia srl).

Patients with a history of treated periodontitis were characterized by previously assessed chronic forms of periodontal disease, corresponding to stage I, II or III, and grade A or B, according to the latest updates on classification of periodontal and peri‐implant diseases. 35 These patients were subjects following a regular maintenance program on a reduced periodontium every 3 months to ensure gingival health at the time of implant placement. On the other hand, periodontally healthy patients were subjects never affected by any form of periodontal disease. 33

Peri‐implant bone levels were measured through digitally scanned intraoral radiographs, performed with a paralleling technique, using Rinn centering devices (Rinn XCP Posterior Aiming Ring‐Yellow; Dentsply). This was done immediately after implant placement, at healing abutment placement, at prosthetic loading, and after 5 years of loading. Measurements were taken as previously described. 22 , 31 , 32 , 33 The IAI was taken as a reference for measurements (Figure A1). CBL was measured on mesial and distal sides as the linear distance between the IAI and the highest point of the interproximal bone crest parallel to the lateral sides of the implant body: a positive value was given when the crest was located coronally to the IAI and a negative value when the crest was located apically to the IAI; for every implant, at each examination interval, an average mesial‐distal value was calculated. F‐BIC was defined as the first most coronal bone‐to‐implant relationship visible at the first line of contact, on both mesial and distal sides; if F‐BIC matches with IAI, the measurement was 0; if it is located apically, the measurement was a positive value. 22 , 31 , 32 , 33 As described in the literature, implants were divided into two groups on the basis of presenting a CIR less than or greater than 2. The crown height was measured on the radiograph immediately after the prosthetic loading, from the most occlusal point to the IAI. Anatomical CIR (in which the fulcrum is positioned at the interface between the implant shoulder and the crown‐abutment complex) was calculated by dividing the digital length of the crown by the digital length of the implant. 22 , 31 , 32 , 33

Measurements were assessed with the aid of a software program (Rasband, W.S., ImageJ, U. S. National Institutes of Health) which uses a measuring tool in conjunction with a magnification tool. To correct the distortion of the radiographic image, the apparent size of each implant (measured directly on the radiograph) was compared with the actual length to determine, with adequate precision, the amount of any changes of the crestal bone around each implant. The measurements were made to the nearest 0.01 mm. One dentist who was not involved in the treatment of the patients completed all the measurements on periapical radiographs; the observation intervals of radiographs were masked to the examiner. Before the start of the study, this investigator was calibrated for adequate intraexaminer levels of accuracy and reproducibility in recording the radiographic parameters. Three radiographs were utilized for this purpose: duplicate measurements for CBL, F‐BIC, and CIR were collected with an interval of 24 h between the first and second recording. The intraclass correlation coefficients, used as a measure of intraexaminer reproducibility, had to be greater than 0.8. 22 , 31 , 32 , 33

The study presents compliance with the STROBE checklist guidelines. 80

Lombardo G, Signoriello A, Marincola M, Liboni P, Bonfante EA, Nocini PF. Survival rates of ultra‐short (<6 mm) compared with short locking‐taper implants supporting single crowns in posterior areas: A 5‐year retrospective study. Clin Implant Dent Relat Res. 2021;23(6):904‐919. doi: 10.1111/cid.13054

DATA AVAILABILITY STATEMENT

The data that support the findings of this study are available from the corresponding author upon reasonable request.

REFERENCES

  • 1. Couso‐Queiruga E, Stuhr S, Tattan M, Chambrone L, Avila‐Ortiz G. Post‐extraction dimensional changes: A systematic review and meta‐analysis. J Clin Periodontol. 2021;48(1):126‐144. doi: 10.1111/jcpe.13390 [DOI] [PubMed] [Google Scholar]
  • 2. Chiapasco M, Zaniboni M. Failures in jaw reconstructive surgery with autogenous onlay bone grafts for pre‐implant purposes: incidence, prevention and management of complications. Oral Maxillofac Surg Clin North Am. 2011;23(1):1‐15. doi: 10.1016/j.coms.2010.10.009 [DOI] [PubMed] [Google Scholar]
  • 3. Neugebauer J, Nickenig H, Zoller J. Update on short, angulated a diameter‐reduced implants. Paper presented at: Proceedings of the 11th European Consensus Conference, European Association of Dental Implantologists; February 6, 2016; Bonn, Germany.
  • 4. Mezzomo LA, Miller R, Triches D, Alonso F, Shinkai RS. Meta‐analysis of single crowns supported by short (<10 mm) implants in the posterior region. J Clin Periodontol. 2014;41(2):191‐213. doi: 10.1111/jcpe.12180 [DOI] [PubMed] [Google Scholar]
  • 5. Thoma DS, Zeltner M, Husler J, Hammerle CH, Jung RE. EAO Supplement Working Group 4—EAO CC 2015 short implants versus sinus lifting with longer implants to restore the posterior maxilla: a systematic review. Clin Oral Implants Res. 2015;26(11):154‐169. [DOI] [PubMed] [Google Scholar]
  • 6. Lemos CA, Ferro‐Alves ML, Okamoto R, Mendonça MR, Pellizzer EP. Short dental implants versus standard dental implants placed in the posterior jaws: a systematic review and meta‐analysis. J Dent. 2016;47:8‐17. doi: 10.1016/j.jdent.2016.01.005 [DOI] [PubMed] [Google Scholar]
  • 7. Fan T, Li Y, Deng WW, Wu T, Zhang W. Short implants (5 to 8 mm) versus longer implants (>8 mm) with sinus lifting in atrophic posterior maxilla: a meta‐analysis of RCTs. Clin Implant Dent Relat Res. 2017;19(1):207‐215. doi: 10.1111/cid.12432 [DOI] [PubMed] [Google Scholar]
  • 8. Nisand D, Renouard F. Short implant in limited bone volume. Periodontology 2000. 2014;66(1):72‐96. doi: 10.1111/prd.12053 [DOI] [PubMed] [Google Scholar]
  • 9. Buser D, Janner SF, Wittneben JG, Bragger U, Ramseier CA, Salvi GE. 10‐year survival and success rates of 511 titanium implants with a sandblasted and acid‐etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res. 2012;14(6):839‐851. doi: 10.1111/j.1708-8208.2012.00456.x [DOI] [PubMed] [Google Scholar]
  • 10. Meng HW, Chien EY, Chien HH. Dental implant bioactive surface modifications and their effects on osseointegration: a review. Biomark Res. 2016;4:24. doi: 10.1186/s40364-016-0078-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Salama AA, Katamish HA, Halim CH, Farid KA. The mechanical complications of platform switching connection of implant supported restorations: a systematic review and meta‐analysis. J Osseointegr. 2019;11(3):3. doi: 10.23805/JO.2019.11.03.03 [DOI] [Google Scholar]
  • 12. Coelho PG, Marin C, Granato R, Suzuki M. Histomorphologic analysis of 30 plateau root form implants retrieved after 8 to 13 years in function. A human retrieval study. J Biomed Mater Res B Appl Biomater. 2009;91(2):975‐979. doi: 10.1002/jbm.b.31455 [DOI] [PubMed] [Google Scholar]
  • 13. Malchiodi L, Caricasulo R, Cucchi A, Vinci R, Agliardi E, Gherlone E. Evaluation of ultrashort and longer implants with microrough surfaces: results of a 24‐ to 36‐month prospective study. Int J Oral Maxillofac Implants. 2017;32(1):171‐179. doi: 10.11607/jomi.4648 [DOI] [PubMed] [Google Scholar]
  • 14. de Souza PTR, Martini MBA, Azevedo‐Alanis LR. Do short implants have similar survival rates compared to standard implants in posterior single crown?: A systematic review and meta‐analysis. Clin Implant Dent Relat Res. 2018;20(5):890‐901. doi: 10.1111/cid.12634 [DOI] [PubMed] [Google Scholar]
  • 15. Papaspyridakos P, De Souza A, Vazouras K, Gholami H, Pagni S, Weber HP. Survival rates of short dental implants (≤6 mm) compared with implants longer than 6 mm in posterior jaw areas: a meta‐analysis. Clin Oral Implants Res. 2018;29(16):8‐20. doi: 10.1111/clr.13289 [DOI] [PubMed] [Google Scholar]
  • 16. Ravidà A, Wang IC, Barootchi S, et al. Meta‐analysis of randomized clinical trials comparing clinical and patient‐reported outcomes between extra‐short (≤6 mm) and longer (≥10 mm) implants. J Clin Periodontol. 2019;46(1):118‐142. doi: 10.1111/jcpe.13026 [DOI] [PubMed] [Google Scholar]
  • 17. Esposito M, Buti J, Barausse C, Gasparro R, Sammartino G, Felice P. Short implants versus longer implants in vertically augmented atrophic mandibles: a systematic review of randomised controlled trials with a 5‐year post‐loading follow‐up. Int J Oral Implantol (Berl). 2019;12(3):267‐280. [PubMed] [Google Scholar]
  • 18. Vazouras K, de Souza AB, Gholami H, Papaspyridakos P, Pagni S, Weber HP. Effect of time in function on the predictability of short dental implants (≤6 mm): a meta‐analysis. J Oral Rehabil. 2020;47(3):403‐415. doi: 10.1111/joor.12925 [DOI] [PubMed] [Google Scholar]
  • 19. Xu X, Hu B, Xu Y, Liu Q, Ding H, Xu L. Short versus standard implants for single‐crown restorations in the posterior region: a systematic review and meta‐analysis. J Prosthet Dent. 2020;124(5):530‐538. doi: 10.1016/j.prosdent.2019.09.030 [DOI] [PubMed] [Google Scholar]
  • 20. Lee SA, Lee CT, Fu MM, Elmisalati W, Chuang SK. Systematic review and meta‐analysis of randomized controlled trials for the management of limited vertical height in the posterior region: short implants (5 to 8 mm) vs longer implants (>8 mm) in vertically augmented sites. Int J Oral Maxillofac Implants. 2014;29(5):1085‐1097. doi: 10.11607/jomi.3504 [DOI] [PubMed] [Google Scholar]
  • 21. Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta‐analysis of observational studies. J Clin Periodontol. 2011;38(9):856‐863. doi: 10.1111/j.1600-051X.2011.01750.x [DOI] [PubMed] [Google Scholar]
  • 22. Lombardo G, Signoriello A, Simancas‐Pallares M, Marincola M, Nocini PF. Survival of short and ultra‐short locking‐taper implants supporting single crowns in the posterior mandible: a 3‐year retrospective study. J Oral Implantol. 2020;46(4):396‐406. doi: 10.1563/aaid-joi-D-19-00190 [DOI] [PubMed] [Google Scholar]
  • 23. Villarinho EA, Triches DF, Alonso FR, Mezzomo LAM, Teixeira ER, Shinkai RSA. Risk factors for single crowns supported by short (6‐mm) implants in the posterior region: a prospective clinical and radiographic study. Clin Implant Dent Relat Res. 2017;19(4):671‐680. doi: 10.1111/cid.12494 [DOI] [PubMed] [Google Scholar]
  • 24. Klokkevold PR, Han TJ. How do smoking, diabetes, and periodontitis affect outcomes of implant treatment? Int J Oral Maxillofac Implants. 2007;22:173‐202. [PubMed] [Google Scholar]
  • 25. Akram Z, Vohra F, Sheikh SA, Albaijan R, Bukhari IA, Hussain M. Clinical and radiographic peri‐implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: a 3‐year follow‐up study. Clin Implant Dent Relat Res. 2019;21(4):775‐780. doi: 10.1111/cid.12761 [DOI] [PubMed] [Google Scholar]
  • 26. Erbasar GNH, Hocaoğlu TP, Erbasar RC. Risk factors associated with short dental implant success: a long‐term retrospective evaluation of patients followed up for up to 9 years. Braz Oral Res. 2019;33:e030. doi: 10.1590/1807-3107bor-2019.vol33.0030 [DOI] [PubMed] [Google Scholar]
  • 27. Mombelli A, Lang NP. Clinical parameters for the evaluation of dental implants. Periodontol 2000. 1994;4:81‐86. doi: 10.1111/j.1600-0757.1994.tb00008.x [DOI] [PubMed] [Google Scholar]
  • 28. Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6‐mm‐long implants with a moderately rough surface: a prospective 2‐year follow‐up cohort study. Clin Oral Implants Res. 2010;21(9):937‐943. doi: 10.1111/j.1600-0501.2010.01942.x [DOI] [PubMed] [Google Scholar]
  • 29. Naenni N, Sahrmann P, Schmidlin PR, et al. Five‐year survival of short single‐tooth implants (6 mm): a randomized controlled clinical trial. J Dent Res. 2018;97(8):887‐892. doi: 10.1177/0022034518758036 [DOI] [PubMed] [Google Scholar]
  • 30. Guljé FL, Raghoebar GM, Vissink A, Meijer HJA. Single crown restorations supported by 6‐mm implants in the resorbed posterior mandible: a five‐year prospective case series. Clin Implant Dent Relat Res. 2019;21(5):1017‐1022. doi: 10.1111/cid.12825 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31. Lombardo G, Pighi J, Marincola M, Corrocher G, Simancas‐Pallares M, Nocini PF. Cumulative success rate of short and ultrashort implants supporting single crowns in the posterior maxilla: a 3‐year retrospective study. Int J Dent. 2017;2017:8434281. doi: 10.1155/2017/8434281 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32. Lombardo G, Marincola M, Signoriello A, Corrocher G, Nocini PF. Single‐crown, short and ultra‐short implants, in association with simultaneous internal sinus lift in the atrophic posterior maxilla: a three‐year retrospective study. Materials. 2020;13(9):2208. doi: 10.3390/ma13092208 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Lombardo G, Signoriello A, Marincola M, Nocini PF. Assessment of peri‐implant soft tissues conditions around short and ultra‐short implant‐supported single crowns: a 3‐year retrospective study on periodontally healthy patients and patients with a history of periodontal disease. Int J Environ Res Public Health. 2020;17(24):9354. doi: 10.3390/ijerph17249354 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Urdaneta RA, Marincola M. The Integrated Abutment Crownt, a screwless and cementless restoration for single‐tooth implants: a report on a new technique. J Prosthodont. 2007;16(4):311‐318. doi: 10.1111/j.1532-849X.2007.00194.x [DOI] [PubMed] [Google Scholar]
  • 35. Caton JG, Armitage G, Berglundh T, et al. A new classification scheme for periodontal and peri‐implant diseases and conditions—introduction and key changes from the 1999 classification. J Clin Periodontol. 2018;45(20):S1‐S8. doi: 10.1111/jcpe.12935 [DOI] [PubMed] [Google Scholar]
  • 36. Urdaneta RA, Daher S, Leary J, Emanuel KM, Chuang SK. The survival of ultrashort locking‐taper implants. Int J Oral Maxillofac Implants. 2012;27(3):644‐654. [PubMed] [Google Scholar]
  • 37. Mangano FG, Shibli JA, Sammons RL, Iaculli F, Piattelli A, Mangano C. Short (8‐mm) locking‐taper implants supporting single crowns in posterior region: a prospective clinical study with 1‐ to 10‐years of follow‐up. Clin Oral Implants Res. 2014;25(8):933‐940. doi: 10.1111/clr.12181 [DOI] [PubMed] [Google Scholar]
  • 38. Maiorana C, Farronato D, Pieroni S, Cicciu M, Andreoni D, Santoro F. A four‐year survival rate multicenter prospective clinical study on 377 implants: correlations between implant insertion torque, diameter, and bone quality. J Oral Implantol. 2015;41(3):e60‐e65. doi: 10.1563/AAID-JOI-D-13-00206 [DOI] [PubMed] [Google Scholar]
  • 39. Malchiodi L, Cucchi A, Ghensi P, Consonni D, Nocini PF. Influence of crown‐implant ratio on implant success rates and crestal bone levels: a 36‐month follow‐up prospective study. Clin Oral Implants Res. 2014;25(2):240‐251. doi: 10.1111/clr.12105 [DOI] [PubMed] [Google Scholar]
  • 40. Urdaneta RA, Rodriguez S, McNeil DC, Weed M, Chuang SK. The effect of increased crown‐to‐implant ratio on single‐tooth locking‐taper implants. Int J Oral Maxillofac Implants. 2010;25(4):729‐743. [PubMed] [Google Scholar]
  • 41. Birdi H, Schulte J, Kovacs A, Weed M, Chuang SK. Crown‐to‐implant ratios of short‐length implants. J Oral Implantol. 2010;36(6):425‐433. doi: 10.1563/AAID-JOI-D-09-00071 [DOI] [PubMed] [Google Scholar]
  • 42. Berglundh T, Armitage G, Araujo MG, et al. Peri‐implant diseases and conditions: consensus report of workgroup 4 of the 2017 world workshop on the classification of periodontal and peri‐implant diseases and conditions. J Periodontol. 2018;89(1):S313‐S318. doi: 10.1002/JPER.17-0739 [DOI] [PubMed] [Google Scholar]
  • 43. Buser D, Weber HP, Bragger U, Balsiger C. Tissue integration of one‐stage ITI implants: 3‐year results of a longitudinal study with hollow‐cylinder and hollow‐screw implants. Int J Oral Maxillofac Implants. 1991;6(4):405‐412. [PubMed] [Google Scholar]
  • 44. Albrektsson T, Zarb GA. Determinants of correct clinical reporting. Int J Prosthodont. 1998;11(5):517‐521. [PubMed] [Google Scholar]
  • 45. Lombardo G, Marincola M, Cicconetti A, et al. Successful management of peri‐implantitis around short and ultrashort single‐crown implants: a case series with a 3‐year follow‐up. Int J Dent. 2019;2019:5302752. doi: 10.1155/2019/5302752 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Anitua E, Piñas L, Orive G. Retrospective study of short and extra‐short implants placed in posterior regions: influence of crown‐to‐implant ratio on marginal bone loss. Clin Implant Dent Relat Res. 2015;17(1):102‐110. doi: 10.1111/cid.12073 [DOI] [PubMed] [Google Scholar]
  • 47. Nunes M, Almeida RF, Felino AC, Malo P, de Araújo Nobre M. The influence of crown‐to‐implant ratio on short implant marginal bone loss. Int J Oral Maxillofac Implants. 2016;31(5):1156‐1163. doi: 10.11607/jomi.4336 [DOI] [PubMed] [Google Scholar]
  • 48. Guljé FL, Meijer HJA, Abrahamsson I, et al. Comparison of 6‐mm and 11‐mm dental implants in the posterior region supporting fixed dental prostheses: 5‐year results of an open multicenter randomized controlled trial. Clin Oral Implants Res. 2021;32(1):15‐22. doi: 10.1111/clr.13674 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Rossi F, Botticelli D, Cesaretti G, De Santis E, Storelli S, Lang NP. Use of short implants (6 mm) in a single‐tooth replacement: a 5‐year follow‐up prospective randomized controlled multicenter clinical study. Clin Oral Implants Res. 2016;27(4):458‐464. doi: 10.1111/clr.12564 [DOI] [PubMed] [Google Scholar]
  • 50. Feine J, Abou‐Ayash S, Al Mardini M, et al. Group 3 ITI consensus report: patient‐reported outcome measures associated with implant dentistry. Clin Oral Implants Res. 2018;29(16):270‐275. doi: 10.1111/clr.13299 [DOI] [PubMed] [Google Scholar]
  • 51. de Souza Batista VE, Verri FR, Lemos CAA, et al. Should the restoration of adjacent implants be splinted or nonsplinted? A systematic review and meta‐analysis. J Prosthet Dent. 2019;121(1):41‐51. doi: 10.1016/j.prosdent.2018.03.004 [DOI] [PubMed] [Google Scholar]
  • 52. Mendonça JA, Francischone CE, Senna PM, Matos de Oliveira AE, Sotto‐Maior BS. A retrospective evaluation of the survival rates of splinted and non‐splinted short dental implants in posterior partially edentulous jaws. J Periodontol. 2014;85(6):787‐794. doi: 10.1902/jop.2013.130193 [DOI] [PubMed] [Google Scholar]
  • 53. Sotto‐Maior BS, Senna PM, da Silva WJ, Rocha EP, Del Bel Cury AA. Influence of crown‐to‐implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants. Int J Oral Maxillofac Implants. 2012;27(3):e13‐e18. [PubMed] [Google Scholar]
  • 54. Bulaqi HA, Mashhadi MM, Safari H, Samandari MM, Geramipanah F. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: a finite element analysis. J Prosthet Dent. 2015;113(6):548‐557. doi: 10.1016/j.prosdent [DOI] [PubMed] [Google Scholar]
  • 55. English CE. Biomechanical concerns with fixed partial dentures involving implants. Implant Dent. 1993;2(4):221‐242. doi: 10.1097/00008505-199312000-00002 [DOI] [PubMed] [Google Scholar]
  • 56. Deporter D, Ogiso B, Sohn DS, Ruljancich K, Pharoah M. Ultrashort sintered porous‐surfaced dental implants used to replace posterior teeth. J Periodontol. 2008;79(7):1280‐1286. doi: 10.1902/jop.2008.070496 [DOI] [PubMed] [Google Scholar]
  • 57. Esposito M, Pistilli R, Barausse C, Felice P. Three‐year results from a randomised controlled trial comparing prostheses supported by 5‐mm long implants or by longer implants in augmented bone in posterior atrophic edentulous jaws. Eur J Oral Implantol. 2014;7:383‐395. [PubMed] [Google Scholar]
  • 58. Esposito M, Barausse C, Pistilli R, et al. Posterior jaws rehabilitated with partial prostheses supported by 4.0x4.0 mm or by longer implants: four‐month post‐loading data from a randomised controlled trial. Eur J Oral Implantol. 2015;8:221‐230. [PubMed] [Google Scholar]
  • 59. Slotte C, Grønningsaeter A, Halmøy AM, et al. Four‐millimeter‐long posterior‐mandible implants: 5‐year outcomes of a prospective multicenter study. Clin Implant Dent Relat Res. 2015;17(2):e385‐e395. doi: 10.1111/cid.12252 [DOI] [PubMed] [Google Scholar]
  • 60. Bozkaya D, Muftu S, Muftu A. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. J Prosthet Dent. 2004;92(6):523‐530. doi: 10.1016/j.prosdent.2004.07.024 [DOI] [PubMed] [Google Scholar]
  • 61. Urdaneta RA, Seemann R, Dragan IF, Lubelski W, Leary J, Chuang SK. A retrospective radiographic study on the effect of natural tooth‐implant proximity and an introduction to the concept of a bone‐loading platform switch. Int J Oral Maxillofac Implants. 2014;29(6):1412‐1424. doi: 10.11607/jomi.3699 [DOI] [PubMed] [Google Scholar]
  • 62. Schulte J, Flores AM, Weed M. Crown‐to‐implant ratios of single tooth implant‐supported restorations. J Prosthet Dent. 2007;98(1):1‐5. doi: 10.1016/S0022-3913(07)60031-6 [DOI] [PubMed] [Google Scholar]
  • 63. Coelho PG, Bonfante EA, Marin C, Granato R, Giro G, Suzuki M. A human retrieval study of plasma‐sprayed hydroxyapatite‐coated plateau root form implants after 2 months to 13 years in function. J Long Term Eff Med Implants. 2010;20(4):335‐342. doi: 10.1615/jlongtermeffmedimplants.v20.i4.80 [DOI] [PubMed] [Google Scholar]
  • 64. Gil LF, Suzuki M, Janal MN, et al. Progressive plateau root form dental implant osseointegration: A human retrieval study. J Biomed Mater Res B Appl Biomater. 2015;103:1328‐1332. [DOI] [PubMed] [Google Scholar]
  • 65. Baldassarri M, Bonfante E, Suzuki M, et al. Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3‐24 years of function. J Biomed Mater Res B Appl Biomater. 2012;100(7):2015‐2021. doi: 10.1002/jbm.b.32786 [DOI] [PubMed] [Google Scholar]
  • 66. Dibart S, Warbington M, Su MF, Skobe Z. In vitro evaluation of the implant‐abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants. 2005;20:732‐737. [PubMed] [Google Scholar]
  • 67. Chou HY, Romanas G, Müftü A, Müftü S. Peri‐implant bone remodeling around an extraction socket: predictions of bone maintenance by finite element method. Int J Oral Maxillofac Implants. 2012;27:39‐48. [PubMed] [Google Scholar]
  • 68. Bordin D, Bergamo ETP, Bonfante EA, Fardin VP, Coelho PG. Influence of platform diameter in the reliability and failure mode of extra‐short dental implants. J Mech Behav Biomed Mater. 2018;77:470‐474. doi: 10.1016/j.jmbbm.2017.09.020 [DOI] [PubMed] [Google Scholar]
  • 69. Monje A, Chan HL, Fu JH, Suarez F, Galindo‐Moreno P, Wang HL. Are short dental implants (<10 mm) effective? A meta‐analysis on prospective clinical trials. J Periodontol. 2013;84(7):895‐904. doi: 10.1902/jop.2012.120328 [DOI] [PubMed] [Google Scholar]
  • 70. Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro‐rough surface implants: a review of literature and meta‐analysis. Clin Oral Implants Res. 2014;25(5):539‐545. doi: 10.1111/clr.12125 [DOI] [PubMed] [Google Scholar]
  • 71. Sun HL, Huang C, Wu YR, Shi B. Failure rates of short (≤10 mm) dental implants and factors influencing their failure: a systematic review. Int J Oral Maxillofac Implants. 2011;26(4):816‐825. [PubMed] [Google Scholar]
  • 72. Omran MT, Miley DD, McLeod DE, Garcia MN. Retrospective assessment of survival rate for short endosseous dental implants. Implant Dent. 2015;24(2):185‐191. doi: 10.1097/ID.0000000000000229 [DOI] [PubMed] [Google Scholar]
  • 73. Han J, Zhang X, Tang Z, Zhang L, Shi D, Meng H. A prospective, multicenter study assessing the DENTSPLY implants, OsseoSpeed(™) TX, length 6 mm in the posterior maxilla and mandible: a 1‐year follow‐up study. Clin Oral Implants Res. 2016;27(4):452‐457. doi: 10.1111/clr.12587 [DOI] [PubMed] [Google Scholar]
  • 74. Correia F, Gouveia S, Felino AC, Costa AL, Almeida RF. Survival rate of dental implants in patients with history of periodontal disease: a retrospective cohort study. Int J Oral Maxillofac Implants. 2017;32(4):927‐934. doi: 10.11607/jomi.3732 [DOI] [PubMed] [Google Scholar]
  • 75. Kanao M, Nakamoto T, Kajiwara N, Kondo Y, Masaki C, Hosokawa R. Comparison of plaque accumulation and soft‐tissue blood flow with the use of full‐arch implant‐supported fixed prostheses with mucosal surfaces of different materials: a randomized clinical study. Clin Oral Implants Res. 2013;24(10):1137‐1143. doi: 10.1111/j.1600-0501.2012.02523.x [DOI] [PubMed] [Google Scholar]
  • 76. Agustín‐Panadero R, Soriano‐Valero S, Labaig‐Rueda C, Fernández‐Estevan L, Solá‐Ruíz MF. Implant‐supported metal‐ceramic and resin‐modified ceramic crowns: a 5‐year prospective clinical study. J Prosthet Dent. 2020;124(1):46‐52.e2. doi: 10.1016/j.prosdent.2019.07.002 [DOI] [PubMed] [Google Scholar]
  • 77. Bonfante EA, Suzuki M, Lorenzoni FC, et al. Probability of survival of implant‐supported metal ceramic and CAD/CAM resin nanoceramic crowns. Dent Mater. 2015;31(8):e168‐e177. doi: 10.1016/j.dental.2015.05.006 [DOI] [PubMed] [Google Scholar]
  • 78. Chochlidakis K, Einarsdottir E, Tsigarida A, et al. Survival rates and prosthetic complications of implant fixed complete dental prostheses: an up to 5‐year retrospective study. J Prosthet Dent. 2020;124(5):539‐546. doi: 10.1016/j.prosdent.2019.11.022 [DOI] [PubMed] [Google Scholar]
  • 79. Ohlmann B, Bermejo JL, Rammelsberg P, Schmitter M, Zenthöfer A, Stober T. Comparison of incidence of complications and aesthetic performance for posterior metal‐free polymer crowns and metal‐ceramic crowns: results from a randomized clinical trial. J Dent. 2014;42(6):671‐676. doi: 10.1016/j.jdent.2014.03.002 [DOI] [PubMed] [Google Scholar]
  • 80. von Elm E, Altman DG, Egger M, Pocock SJ, Gotzsche PC, Vandenbroucke JP. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Lancet. 2007;370(9596):1453‐1457. doi: 10.1016/s0140-6736(07)61602-x [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.


Articles from Clinical Implant Dentistry and Related Research are provided here courtesy of Wiley

RESOURCES