Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2022 Jul 27;12:12875. doi: 10.1038/s41598-022-17063-9

Quantitative analysis of exosomes in the aqueous humor of Korean patients with pseudoexfoliation glaucoma

Hyo Jung An 1,2, Hyun-kyung Cho 2,3,, Dae Hyun Song 1,2, Changwon Kee 4
PMCID: PMC9329372  PMID: 35896586

Abstract

We aimed to quantitatively analyze the exosome and its cargo in individual aqueous humor (AH) samples from pseudoexfoliation (PEX) glaucoma patients compared to controls using a novel detection platform. We investigated the size distribution and measured the quantitative exosome particle counts in each AH sample. AH (80–120 µL) was obtained during cataract surgery or glaucoma filtering surgery from 12 Korean subjects (six with PEX glaucoma and six age-matched controls). The mean size of the exosomes was 58.9 ± 18.5 nm measured by a tangential flow filtration system using single-particle interferometric reflectance imaging sensor. Exosome particle count in each CD 63, CD 81, and CD9 spot was significantly greater in PEX glaucoma than in controls in total, CD 63, CD9, syntenin, and scattering(all p < 0.003). The CD63 spot showed a particle count of 8319.1 ± 797.7 in PEX glaucoma patients and 4786.8 ± 1302.1 in controls (p = 1.88E−11). Individual fluorescent capture spot images also revealed denser exosome particles in PEX patients than in controls. Syntenin, indicating exosomal origin, was detected in all AH samples. Exosomes differentially detected in AH suggest the possible role of exosomes in the pathogenesis of PEX glaucoma.

Subject terms: Nanoparticles, Optic nerve diseases

Introduction

Glaucoma is the second most common cause of visual deficit in the world, which ultimately can bring about blindness1,2. The recent global population with primary open-angle glaucoma (POAG) is approximated to be 68.56 million1. Asians comprise half (53.81%) of the POAG patients1. Glaucoma, as a neurodegenerative disease, has pathological characteristics of retinal ganglion cell (RGC) death3. Pseudoexfoliation (PEX) syndrome is a disorder related to age and associated with extracellular matrix. It is the most common distinguishable cause of secondary glaucoma, called PEX glaucoma4. It features progressive accumulation of white fibrillar materials in various extra- and intra-ocular tissues4. PEX glaucoma is usually more aggressive and the response to hypotensive medications is less than POAG4. It also exibits higher intraocular pressure (IOP). The pathophysiology of PEX syndrome has not yet been uncovered, even though it is speculated to have a genetic basis57.

Exosomes are small vesicles which have a diameter of approximately 30–150 nm and are enclosed by a double-layered lipid membrane8. They carry proteins, mRNA, or miRNA and transport them to adjacent or distant cells9. Exosomes are secreted by several types of cells and discovered in numerous body fluids, including blood plasma, urine, and aqueous humor (AH)1012. The main function of exosomes involves intercellular communication by transporting exosomal RNA and protein between cells. Therefore, exosomes have emerged as important biomarkers in a number of human diseases11,13,14.

AH has the main role of providing nutrition, removing excretory products from metabolism, transporting neurotransmitters, and contributing to the regulation of homeostasis in ocular tissues15. Latest studies proposed that there are potential modulators in AH, for example, growth factors and hormones, which may be involved in cellular communication between ocular tissues1618. These regulators are related with the pathogenesis of numerous eye diseases14,19,20.

Exosomes were detected in AH in previous studies12,19,21. Among them, Dismuke et al. collected exosomes from human AH during surgery on cataract patients and isolated them using ultracentrifugation12. They extracted RNA from pooled human AH and discovered and hypothesized that miRNAs within exosomes may assist in communication between AH inflow and outflow tissue12. However, they did not include patients with specific ocular diseases such as glaucoma. They only included cataract patients undergoing cataract surgery or those with diabetes or myopia. Thus, the role of exosomes in a specific ocular disease like glaucoma has not been investigated. Furthermore, exosomes from the AH of the specific glaucoma type PEX glaucoma have not been investigated before, especially in a single ethnic group of Koreans.

Previous studies did not use a novel detection platform based on a single-particle interferometric reflectance imaging sensor and a tangential flow filtration system-based method for high-yield separation and the analysis of exosomal bioactivity. Using this method, small amounts of individual AH samples could be analyzed without pooling all samples. Moreover, this novel detection platform could provide the quantitative analysis of particle counts, in addition to analyzing the size and cargo.

In the present study, we investigated the size distribution and quantified exosome particles in AH from PEX glaucoma patients compared to controls using a novel detection platform in Koreans without pooling the samples. We intended to see differentially detected exosomes, which might suggest a role of exosomes in the pathogenesis of PEX glaucoma or might provide some clues to the pathogenesis of PEX glaucoma.

Results

Baseline characteristics and demographics of the subjects

Six PEX patients and six age-matched control subjects were included in the final analysis. The demographics of the included subjects are presented in Table 1. The mean age of the PEX glaucoma subjects was 73.3 ± 9.9 years (n = 6) and 69.3 ± 38.1 years for the control subjects (n = 6). The mean baseline IOP was 30.7 ± 4.3 mmHg in the PEX glaucoma subjects and 13.2 ± 1.9 mmHg in the control subjects. The baseline mean deviation (MD) was -24.6 ± 4.7 dB in the PEX glaucoma group. The PEX glaucoma patients were using multiple topical anti-glaucoma medications (all three medications) before glaucoma filtering surgery. No control subjects were using topical anti-glaucoma medications. The included subjects had no ocular comorbidities other than simple cataracts.

Table 1.

Baseline characteristics and demographics of subjects.

Subject number Disease status Age, y Sex Eye laterality Mean IOP, mmHg Topical medication Type of surgery
1 Control 65 Female Right 12 None Phaco + PCL
2 Control 75 Male Left 15 None Phaco + PCL
3 Control 68 Female Right 14 None Phaco + PCL
4 Control 75 Male Right 10 None Phaco + PCL
5 Control 62 Female Left 13 None Phaco + PCL
6 Control 47 Male Left 15 None Phaco + PCL
7 PEX G 67 Male Left 26 Timolol/bimatoprost, brinzolamide, brimonidine Ahmed valve
8 PEX G 58 Male Left 25 Dorzolamide/timolol, brimonidine, bimatoprost Ahmed valve
9 PEX G 81 Female Left 33 Dorzolamide/timolol, brimonidine, bimatoprost Ahmed valve
10 PEX G 83 Male Left 31 Brinzolamide/timolol, brimonidine, bimatoprost Ahmed valve
11 PEX G 81 Male Left 33 Dorzolamide/timolol, brimonidine, bimatoprost Ahmed valve
12 PEX G 70 Male Left 36 Dorzolamide/timolol, brimonidine, bimatoprost Trabeculectomy

IOP intraocular pressure, NTG normal tension glaucoma, PEX pseudoexfoliation, G glaucoma, Phaco + PCL phacoemulsification and posterior intraocularlens insertion, Ahmed valve Ahmed valve implantation.

The representative image of extracellular vesicles from aqueous humor

The AH sample from a control subject was collected and the images of extracellular vesicles (EVs) were taken and visualized by transmission electron microscopy (TEM). EVs showed round shape morphology with size up to 170 nm. (Fig. 1) To gain further insight to analyze and characterize exosomes, we performed Exoview analysis to evaluate the size and particle counts of AH exosomes.

Figure 1.

Figure 1

Transmission electron microscopic image of extracellular vesicles of aqueous humor. Numerous extracellular vesicles (EVs) with round shape morphology with various size (left, bar: 500 nm). On higher magnification, EVs up to 170 nm in size are present (right, bar: 200 nm).

Size distribution of the exosomes characterized by Exoview

The range and mean size distribution value of the exosomes in each CD63, CD81, CD9, and MIgG spot in the AH of the patients and corresponding control subjects ranged from 50 to 200 nm (mean = 54.92, 60.92, 57.58, and 62.17 nm, respectively). The mean size of each CD63, CD81, CD9, and MIgG spot in the control subjects was 54.67 ± 10.17 nm for CD63, 61 ± 22.17 nm for CD81, 56 ± 14.67 nm for CD9, and 65.33 ± 27.83 nm for MIgG. The mean size of each spot in the PEX patients was 55.17 ± 11.5 nm for CD63 (p = 0.319), 61.83 ± 24.17 nm for CD81 (p = 0.930), 56.17 ± 15.17 nm for CD9 (p = 0.200), and 65.67 ± 29.33 nm for MIgG (p = 0.250). There were no significant differences in the size distribution of the exosomes between the control group and the PEX glaucoma group (all p > 0.05).

The representative size distribution of AH exosomes from control subject captured by the tetraspanin capture probe, including CD63, CD81, CD9, and MIgG, is shown in Fig. 2A. The mean ± standard deviation was 55 nm ± 10 nm for CD63, 58 ± 17 nm for CD81, 55 ± 15 nm for CD9, and 62 ± 27 nm for MIgG. The representative size distribution of AH exosomes from PEX patients is shown in Fig. 2B. The mean ± standard deviation was 54 ± 6 0 nm for CD63, 56 ± 15 nm for CD81, 55 ± 13 nm for CD9, and 55 ± 13 nm for MIgG.

Figure 2.

Figure 2

Quantitative exosome size distribution (A) Representative size distribution of AH control exosomes captured by the tetraspanin capture probe, including CD63, CD81, CD9, and MIgG is shown (55 ± 10 nm for CD63, 58 ± 17 nm for CD81, 55 ± 15 nm for CD9, and 62 ± 27 nm for MIgG). (B) Representative size distribution of AH exosomes from PEX patients captured (54 ± 60 nm for CD63, 56 ± 15 nm for CD81, 55 ± 13 nm for CD9, and 55 ± 13 nm for MIgG). Data are the mean ± standard deviation.

Exosome particle counts characterized by Exoview

The exosome particle counts in individual patients and the corresponding control subjects were detected and counted according to each tetraspanin capture spot including CD63 (Fig. 3A), CD81 (Fig. 3B), and CD9 (Fig. 3C) and to each capture antibody including CD63, syntenin, and CD9. Compared to the controls, the numbers of exosome particles in the individual AH samples collected from PEX patients tended to be higher (Fig. 3A–C). Images of representative captured spots, including CD63, CD81, and CD9 for control subjects (Fig. 4A–C) and PEX patients (Fig. 4D–F) were visualized. Among each capture antibody detected on each tetraspanin capture spot, CD63 (red color) had the highest number of exosomes, followed by syntenin (green color) and CD9 (blue color). In particular, syntenin with a green-colored capture antibody was detected in all three capture spots. The average counts for EVs with each antibodies (CD63, syntenin, CD9, scattering, CD63/syntenin, CD63/CD9, syntenin/CD9, CD63/scattering, syntenin/scattering, CD9/scattering, CD63/syntenin/CD9, CD63/syntenin/scattering, CD63/CD9/scattering, CD63/syntenin/CD9/scattering) with colocalization of dual, triple, or quadruple-labelled EVs on each tetraspanin chip (CD63, CD81, CD9 and MIgG) were evaluated. The average colocalization counts for EVs in the AH of (A) representative control and (B) PEX glaucoma patient are visualized as the heatmap in the Supplementary Information.

Figure 3.

Figure 3

Quantitative exosome particle counts in individual patients The number of exosome particles detected by capture spots (A) CD63, (B) CD81, and (C) CD9 in one to six individual AH samples collected from PEX patients tended to be higher than in one to six control subjects.

Figure 4.

Figure 4

Representative capture spot images including CD63, CD81, and CD9 in (AC) control subjects and (DF) PEX patients are visualized. Compared to the control subjects (AC), the number of the exosome particles in PEX patient AH samples (DF) was higher. In addition, among each tetraspanin capture antibody detected in each capture spot, CD63 (red color) was present in the highest numbers of the exosomes, followed by syntenin (green color) and CD9 (blue color). In particular, syntenin with a green-colored capture antibody was detected in all three capture spots.

In the grouped clinical data, the average total number of exosome particles in AH PEX samples was 10,414.83 ± 1426.774 for CD63, 3685.278 ± 1347.249 for CD81, and 2514.833 ± 625.0084 for CD9, which was higher and significantly different than the control subjects (5480.389 ± 1522.267 for CD63, 1707.556 ± 604.3676 for CD81, 1378.056 ± 518.0649 for CD9); p = 1.06892E−11 for CD63, p = 2.22692E−06 for CD81, and p = 7.56536E−06 for CD9).

The particle counts of each capture antibody are shown in Fig. 5 and Table 2. For capture spot CD63 (Fig. 5A), the p-value for CD63 was 1.88E−11, and it was 6.03E−06 for syntenin and 0.000115 for CD9. For capture spot CD81 (Fig. 5B), the p-value for CD63 was 1.05546E−05, and it was 2.60321E−09 for syntenin and 0.001288806 for CD9. For capture spot CD9 (Fig. 5C), the p-value for CD63 was 4.65406E−05, and it was 1.67314E−06 for syntenin and 0.031020409 for CD9 (Table 2).

Figure 5.

Figure 5

The number of exosome particles in grouped clinical data. Compared to the control subjects (black-colored in the bar graph), the numbers of the exosome particles in PEX patient AH samples (red-colored in the bar graph) were higher, with statistically significant differences. Capture spot CD63 (A), capture spot C81 (B), and capture spot CD9 (C).

Table 2.

Exosome particle count per each spot between control and PEX glaucoma patients.

Capture spot Capture antibody Control (n = 6) PEX G (n = 6) p-value
CD63 Total 5480.389 ± 1522.267 10,414.83 ± 1426.774 1.07E−11
CD 63 4786.778 ± 1302.085 8319.111 ± 797.6906 1.88E−11
Syntenin 1512.556 ± 692.9516 3734.778 ± 1620.373 6.03E−06
CD 9 312.5 ± 109.7791 569.1667 ± 224.5577 0.000115
Scattering 266.1667 ± 83.86632 543 ± 203.5725 6.32E−06
CD9 Total 1378.056 ± 518.0649 2514.833 ± 625.0084 7.56536E−06
CD 63 579.7222 ± 275.9712 1091.333 ± 321.8783 4.65406E−05
Syntenin 689.9444 ± 282.7952 1372.444 ± 320.5819 1.67314E−06
CD 9 516.1111 ± 220.7308 683.8889 ± 229.8593 0.031020409
Scattering 116.3333 ± 35.26371 233.4444 ± 115.1742 6.48256E−05
CD81 Total 1707.556 ± 604.3676 3685.278 ± 1347.249 2.22692E−06
CD 63 590.1667 ± 245.9087 1501.167 ± 707.0574 1.05546E−05
Syntenin 744.8889 ± 279.5393 1979.722 ± 593.0894 2.60321E−09
CD 9 1047.611 ± 402.4272 1645.111 ± 599.9681 0.001288806
Scattering 71.11111 ± 24.07559 147.2778 ± 101.2439 0.003820417

Bold font indicates significant p values (p < 0.05). p-value by t-test.

PEX pseudoexfoliation, G glaucoma.

Discussion

To the best of our knowledge, the present study was the first to report significantly differentially detected exosomes between controls and a specific type of glaucoma (PEX glaucoma) in individual AH samples without pooling, using a novel detection platform based on a single-particle interferometric reflectance imaging sensor and a tangential flow filtration system-based method. The current study has significant meaning in that the quantitative exosome particle count in each fluorescent capture spot image was analyzed in each AH sample. The PEX glaucoma AH samples had significantly higher exosome particle counts than those in the control group. The fluorescent capture spot images also revealed denser exosome particles in the individual images in PEX patients than in control subjects. The particle size measurement was also quantitatively provided with actual mean and standard deviation values. Moreover, the current study is unique in that all included subjects were Koreans and it was conducted in a single ethnic group. The present study not only detected exosomes in AH but also investigated exosome cargoes including syntenin. The results confirmed that the particles detected in AH were genuine exosomes. These findings suggest the functional participation of exosomes in the pathophysiology of glaucoma, particularly PEX glaucoma.

The term “exosome” was first used in the early 1980s to describe small (30 – 100 nm) vesicles of endosomal origin secreted by reticulocytes22,23. According to Kowal et al., small vesicles (diameter ≈ 30–150 nm) with a low density in gradient ultracentrifugation and carrying tetraspanins (CD63, CD81, and CD9), syntenin-1, and TSG101 proteins, qualified as exosomes24. The role of exosomes in eye and visual system disorders has been described in several reports including review articles25,26. Exosomes are consisted of numerous molecules capable of cellular signaling, which may be used for therapy or for analysis of biomarker. Exosomes are released from cells through the whole body and contain lipids, proteins, carbohydrates, cytokines, miRNA, and RNA cargo. Exosomal surface proteins, carbohydrates, and lipids direct cellular targeting, and can initiate cell surface signaling and affect the mechanism and location of internalization26. Therefore, exosomal molecular profiles and cargo are attractive biomarkers for optic nerve diseases such as glaucoma26.

Several methods including flow cytometry, nanoparticle tracking analysis, and transmission electron microscopic analysis have been used to detect and characterize exosomes. Although conventional flow cytometry of bead-captured vesicles has been used as a convenient approach for multi-parametric and high-throughput characterization of individual cells, it only detects sizes greater than 500 nm. Since small EVs including exosomes were reported to range from 50 to 250 nm in size, advanced imaging flow cytometry combined with exosome-specific monoclonal antibodies has been suggested to supplement conventional flow cytometry analysis27. Meanwhile, nanoparticle tracking analysis (NTA) is a method for analyzing and visualizing particles in liquids that associates the rate of Brownian motion to particle size. Currently, NTA is used for particles from about 10 to 1000 nm in size and has been used for characterizing exosomes12,21. However, there are some limitations. The viscosity of the solvent affects the movement of particles, thus playing a role in establishing the upper size limit, and exosomes should be isolated as pellets for characterization using NTA. Therefore, in this study, we used ExoView®, a novel detection platform based on a single-particle interferometric reflectance imaging sensor (SP-IRIS). Exoview can directly detect exosomes in samples including AH, serum, plasma, urine, or cultured cells without sample purification. Moreover, the volume of the sample required for analyzing exosome size and particle counts using Exoview is much smaller than that for NTA. Exoview uses 35 μL compared to 600 μL for NTA. The minimal sample volume might be the most interesting and distinguishing point since the amount of AH obtained during surgery can be very small. Among other options for Exoview analysis, in this study, we used the Exoview Tetraspanin Cargo kit to characterize human AH exosomes. Importantly, the reason we used the cargo protein syntenin was that it is often offered as proof of the multivesicular body (MVB) origin of exosomes. Syntenin PDZ domains directly bind to multiple syndecan membrane receptors and the tetraspanin CD63 to support exosomal cargo sorting28. Only after sorting, do genetic materials, including miRNAs and other cargo proteins, enter the MVB to differentiate into exosomes.

This exploratory study was limited by the relatively small volume of the AH samples and small sample size. Our results may not represent the whole Asian ethnicity but limited to Korean population. However, it has a significance in that it provides the potential for future research in the field of exosomes in eye disorders, especially, glaucoma. The effect of hypotensive topical medications on AH exosomal profiles and exosomal miRNA expression in PEX glaucoma patients has not been revealed yet. The influence of various hypotensive topical medications on our results is unknown. Future studies including large numbers of samples would be beneficial in controlling the use of topical medications. Nevertheless, glaucoma patients generally take hypotensive anti-glaucoma topical medications, particularly when they decide to undertake ocular surgery except they are discovered to be medication-naïve in the clinic. Because it is not ethical to acquire the AH of patients that are not undergoing ocular surgery in operating rooms or stop medications for glaucoma patients for research purposes, it is not simple to eliminate the effect of hypotensive anti-glaucoma topical medications on the results. In the same context, PEX glaucoma patients with high IOP using multiple hypotensive medications who needed filtering surgery were included in the present study. The effect of including PEX patients with high IOP on the study results is unknown. High IOP and/or the use of hypotensive medications may affect the blood-aqueous-barrier, which may further affect the composition of exosomes. However, according to a recent review article, compromised aqueous-blood barrier was also one of mechanisms involved in the pathogenesis of PEX syndrome and PEX glaucoma29. PEX syndrome usually does not show high IOP or glaucomatous damage in the optic nerve head. Therefore, hypotensive medication is not needed in most cases. However, even eyes with PEX syndrome frequently show clinical signs of impairment of the blood-aqueous-barrier30. The breakdown of the blood-aqueous-barrier is confirmed by an elevation in AH proteins30. Therefore, the disruption of aqueous-blood barrier is not thought to be only affected by high IOP or hypotensive medications, but PEX glaucoma itself also has the property of compromised aqueous-blood barrier. We think the significant difference of exosomes between PEX glaucoma and control shown in the current study is likely due to the own disease of PEX glaucoma.

In conclusion, exosomes from individual AH samples showed a significant difference between PEX glaucoma and control groups in a single ethnic group of Koreans. Exosomes in AH quantitatively assessed by the novel detection platform method revealed significantly higher numbers of exosomes in the PEX glaucoma group compared to the controls, which has not been reported before. Our findings suggest the possible role of exosomes and exosomal cargos in the pathogenesis of PEX glaucoma. Our results also further imply the potential of exosomes as a biomarker for glaucoma, especially PEX glaucoma for diagnosing and providing patient prognoses. Further studies with more numbers of samples are required to draw definitive conclusions.

Methods

Ethics statement

The present study was performed according to the tenets of the Declaration of Helsinki for research concerning human subjects. The present study was approved by the Institutional Review Board of Gyeongsang National University Changwon Hospital, Gyeongsang National University, School of Medicine (GNUCH-2019-06-001-002). Written informed consent was obtained from all subjects included in the present study. All methods were carried out in accordance with relevant guidelines and regulations.

Diagnosis of PEX glaucoma

Subjects were assessed in the glaucoma clinic at Gyeongsang National University Changwon Hospital by a single glaucoma specialist (H.-K. C.). PEX glaucoma was defined by the existence of PEX material at the margin of the pupil and on the anterior lens capsule after maximal pupil dilatation, and all of the following: an initial IOP of at least 22 mmHg, glaucomatous optic disc changes, visual field defects corresponding to optic nerve damage, and no evidence of other conditions causing secondary glaucoma7. All subjects underwent standard ophthalmic examinations including slit-lamp biomicroscopy, gonioscopy, and funduscopy.

Patient selection and acquisition of aqueous humor samples

AH samples were obtained from patients who underwent uneventful phacoemulsification for elective cataract surgery or glaucoma filtering surgery (trabeculectomy or Ahmed glaucoma drainage implant surgery) after obtaining written informed consent. Six PEX glaucoma patients and six age-matched control subjects agreed to take part in the present study. About 80 to 120 μL of AH was obtained by anterior chamber paracentesis with a 30-gauge needle prior to the main corneal incision at the beginning of cataract surgery or during the procedure of paracentesis in trabeculectomy or Ahmed glaucoma drainage implant surgery. Anterior chamber paracentesis was performed under aseptic sterile conditions in the operating room. AH was acquired without trauma to the subjects, thus, excluding any possibility of contamination with blood or cellular debris. All obtained AH samples were anonymized, promptly snap-frozen with liquid nitrogen, and transferred to research laboratories. Clinical data were collected from electronic medical records in a completely anonymized method. The acquired clinical data were age, eye laterality, sex, baseline IOP, use of topical medications, and other ocular comorbidities.

Transmission electron microscopic analysis

10 ul of AH collected form the representative control patient was fixed 1:1 with 2% glutaraldehyde (Tokyo Chemical Industry, G0068) for 30 min. The fixed sample of 6 μL was pipetted onto the 200 mesh copper grid with carbon-coated formvar film, and incubated for 10 min. The grid was washed with 100 μL MilliQ water. The grid was placed on 30 μL of 1.5% uranyl acetate for 12 s. Images were acquired using Bio 120 kV Transmission electron microscope (Thermofisher Scienfitic, Talos L120C)31.

ExoView analysis

The Exoview platform consists of an antibody array to isolate exosomes on the chip based on surface membrane-bound markers and an interferometric imaging technique to detect exosomes using fluorescence. Using the multiplexed microarray, the particle diameter of single exosomes was measured by their light scattering intensity. In addition, exosomes expressing specific surface membrane-bound markers, including tetraspanins (CD63, CD81, and CD9) were counted using three-color fluorescence. Exosome cargo, luminal proteins including ALIX and syntenin, could be probed simultaneously with surface markers using a permeabilization assay. As these methods relied on affinity capture, which could directly detect exosomes in the samples and avoid certain complications and biases associated with sample processing32,33.

The biological and physical properties of exosomes in human AH samples were characterized using Exoview R-100 (Nanoview Bioscience, Boston, MA, USA), ExoView Tetraspanin kits (NanoView Biosciences) including anti-CD81, anti-CD63, anti-CD9, and IgG negative control-immobilized chips, fluorescence-labeling agents, washing solutions (solution A and B) and blocking solution (NanoView Biosciences), the ExoView Tetraspanin Cargo kit, including anti-syntenin antibody, and cargo staining blocking solution, solution C, and solution D. Briefly, 35 uL of sample diluted with solution A was dropped onto Exoview tetraspanin chips and incubated overnight (16 h) at room temperature. After incubation, the sample-loaded chip was washed with 1 mL of solution A, 250 mL of solution C, and 250 mL of solution D 3 times for 3 min. After the last wash, the exosomes on the chip were labeled with 250 uL of a fluorescently labeled antibody mixture of anti-syntenin/AF 555 (green), anti-CD 63/AF 647 (red), and anti-CD 9/AF 488 (blue) and incubated for 1 h at room temperature. The co-localization of tetraspanin on the surface and the exosomal cargo were analyzed. During the process, anti-CD 63/AF 647 and anti-CD 9/AF 488 were diluted at 1:500, and Syntenin/AF 555 was diluted at 1:200 in a mixture of solution A and cargo blocking solution. Finally, the chip was rinsed with 1 mL of solutions A and B 3 times for 3 min and dried at room temperature. The exosome capture chip was scanned using Exoview R-100 and nScan software and the data were analyzed by Exoview Analyzer 3.0 software.

Statistical analysis

Comparison of exosomal particle counts between PEX glaucoma and control groups was performed with the unpaired Student’s t-test (Prism 5; GraphPad Software, La Jolla, CA, USA). A p-value of < 0.05 indicated a statistically significant difference.

Supplementary Information

Acknowledgements

This work was supported by a National Research Foundation of Korea (NRF) Grant (No. 2019R1G1A1007020) funded by the Korean government, Ministry of Science, and ICT (MSIT).

Author contributions

H.C., H.A., and D.S. contributed to the design of the study; H.C., H.A., and D.S. conducted the study; H.C., H.A., D.S., and C.K. contributed to the collection, analysis, management, and interpretation of the data; and H.C. and H.A. prepared the manuscript.

Data availability

The datasets used in the current study might be shared upon reasonable request to Hyun-kyung Cho, MD, PhD.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

The online version contains supplementary material available at 10.1038/s41598-022-17063-9.

References

  • 1.Zhang N, Wang J, Li Y, Jiang B. Prevalence of primary open angle glaucoma in the last 20 years: A meta-analysis and systematic review. Sci. Rep. 2021;11:13762. doi: 10.1038/s41598-021-92971-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Tham YC, et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis. Ophthalmology. 2014;121:2081–2090. doi: 10.1016/j.ophtha.2014.05.013. [DOI] [PubMed] [Google Scholar]
  • 3.Weinreb RN, Khaw PT. Primary open-angle glaucoma. Lancet. 2004;363:1711–1720. doi: 10.1016/S0140-6736(04)16257-0. [DOI] [PubMed] [Google Scholar]
  • 4.Ritch R. Exfoliation syndrome-the most common identifiable cause of open-angle glaucoma. J. Glaucoma. 1994;3:176–177. [PubMed] [Google Scholar]
  • 5.Founti P, et al. Ethnicity-based differences in the association of LOXL1 polymorphisms with pseudoexfoliation/pseudoexfoliative glaucoma: A meta-analysis. Ann. Hum. Genet. 2015;79:431–450. doi: 10.1111/ahg.12128. [DOI] [PubMed] [Google Scholar]
  • 6.Chatzikyriakidou A, et al. MicroRNA-related polymorphisms in pseudoexfoliation syndrome, pseudoexfoliative glaucoma, and primary open-angle glaucoma. Ophthalmic Genet. 2018;39:603–609. doi: 10.1080/13816810.2018.1509352. [DOI] [PubMed] [Google Scholar]
  • 7.Park DY, Won HH, Cho HK, Kee C. Evaluation of lysyl oxidase-like 1 gene polymorphisms in pseudoexfoliation syndrome in a Korean population. Mol. Vis. 2013;19:448–453. [PMC free article] [PubMed] [Google Scholar]
  • 8.Raposo G, Stoorvogel W. Extracellular vesicles: Exosomes, microvesicles, and friends. J. Cell Biol. 2013;200:373–383. doi: 10.1083/jcb.201211138. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Henderson MC, Azorsa DO. The genomic and proteomic content of cancer cell-derived exosomes. Front. Oncol. 2012;2:38. doi: 10.3389/fonc.2012.00038. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Michael A, et al. Exosomes from human saliva as a source of microRNA biomarkers. Oral Dis. 2010;16:34–38. doi: 10.1111/j.1601-0825.2009.01604.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Vlassov AV, Magdaleno S, Setterquist R, Conrad R. Exosomes: Current knowledge of their composition, biological functions, and diagnostic and therapeutic potentials. Biochim. Biophys. Acta. 2012;1820:940–948. doi: 10.1016/j.bbagen.2012.03.017. [DOI] [PubMed] [Google Scholar]
  • 12.Dismuke WM, Challa P, Navarro I, Stamer WD, Liu Y. Human aqueous humor exosomes. Exp. Eye Res. 2015;132:73–77. doi: 10.1016/j.exer.2015.01.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Schneider A, Simons M. Exosomes: Vesicular carriers for intercellular communication in neurodegenerative disorders. Cell Tissue Res. 2013;352:33–47. doi: 10.1007/s00441-012-1428-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Liu Y, et al. A common variant in MIR182 is associated with primary open-angle glaucoma in the NEIGHBORHOOD consortium. Invest. Ophthalmol. Vis. Sci. 2016;57:4528–4535. doi: 10.1167/iovs.16-19688. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Goel M, Picciani RG, Lee RK, Bhattacharya SK. Aqueous humor dynamics: A review. Open Ophthalmol. J. 2010;4:52–59. doi: 10.2174/1874364101004010052. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Coca-Prados M, Escribano J. New perspectives in aqueous humor secretion and in glaucoma: The ciliary body as a multifunctional neuroendocrine gland. Prog. Retin. Eye Res. 2007;26:239–262. doi: 10.1016/j.preteyeres.2007.01.002. [DOI] [PubMed] [Google Scholar]
  • 17.Zhang Y, et al. Enhanced inflow and outflow rates despite lower IOP in bestrophin-2-deficient mice. Invest. Ophthalmol. Vis. Sci. 2009;50:765–770. doi: 10.1167/iovs.08-2501. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Lee YS, et al. Regulation of anterior chamber drainage by bicarbonate-sensitive soluble adenylyl cyclase in the ciliary body. J. Biol. Chem. 2011;286:41353–41358. doi: 10.1074/jbc.M111.284679. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Duan X, et al. Proteomic analysis of aqueous humor from patients with myopia. Mol. Vis. 2008;14:370–377. [PMC free article] [PubMed] [Google Scholar]
  • 20.Ji Y, Rong X, Lu Y. Metabolic characterization of human aqueous humor in the cataract progression after pars plana vitrectomy. BMC Ophthalmol. 2018;18:63. doi: 10.1186/s12886-018-0729-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Gao C, et al. Exosomal miRNA analysis of aqueous humour of diabetes and cataract patients. Curr. Eye Res. 2021;46:324–332. doi: 10.1080/02713683.2020.1797107. [DOI] [PubMed] [Google Scholar]
  • 22.Harding C, Heuser J, Stahl P. Receptor-mediated endocytosis of transferrin and recycling of the transferrin receptor in rat reticulocytes. J. Cell Biol. 1983;97:329–339. doi: 10.1083/jcb.97.2.329. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Pan BT, Teng K, Wu C, Adam M, Johnstone RM. Electron microscopic evidence for externalization of the transferrin receptor in vesicular form in sheep reticulocytes. J. Cell Biol. 1985;101:942–948. doi: 10.1083/jcb.101.3.942. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Kowal J, et al. Proteomic comparison defines novel markers to characterize heterogeneous populations of extracellular vesicle subtypes. Proc. Natl. Acad. Sci. U. S. A. 2016;113:E968–977. doi: 10.1073/pnas.1521230113. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Klingeborn M, Dismuke WM, Bowes Rickman C, Stamer WD. Roles of exosomes in the normal and diseased eye. Prog. Retina Eye Res. 2017;59:158–177. doi: 10.1016/j.preteyeres.2017.04.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.van der Merwe Y, Steketee MB. Extracellular vesicles: Biomarkers, therapeutics, and vehicles in the visual system. Curr. Ophthalmol. Rep. 2017;5:276–282. doi: 10.1007/s40135-017-0153-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Mastoridis S, et al. Multiparametric analysis of circulating exosomes and other small extracellular vesicles by advanced imaging flow cytometry. Front. Immunol. 2018;9:1583. doi: 10.3389/fimmu.2018.01583. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Ghossoub R, et al. Syntenin-ALIX exosome biogenesis and budding into multivesicular bodies are controlled by ARF6 and PLD2. Nat. Commun. 2014;5:3477. doi: 10.1038/ncomms4477. [DOI] [PubMed] [Google Scholar]
  • 29.Chakraborty M, Rao A. Alternate causes for pathogenesis of exfoliation glaucoma, a multifactorial elastotic disorder: A literature review. Curr. Issues Mol. Biol. 2022;44(3):1191–1202. doi: 10.3390/cimb44030078. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Küchle M, Vinores SA, Mahlow J, Green WR. Blood-aqueous barrier in exfoliation syndrome: Evaluation by immunohistochemical staining of endogenous albumin. Graefe’s Arch. Clin. Exp. Ophthalmol. 1996;234:12–18. doi: 10.1007/BF00186513. [DOI] [PubMed] [Google Scholar]
  • 31.Rikkert LG, et al. Quality of extracellular vesicle images by transmission electron microscopy is operator and protocol dependent. J. Extracell. Vesicles. 2019;8:1555419. doi: 10.1080/20013078.2018.1555419. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Consortium, E.-T et al. EV-TRACK: Transparent reporting and centralizing knowledge in extracellular vesicle research. Nat. Methods. 2017;14:228–232. doi: 10.1038/nmeth.4185. [DOI] [PubMed] [Google Scholar]
  • 33.Thery C, et al. Minimal information for studies of extracellular vesicles 2018 (MISEV2018): A position statement of the International Society for Extracellular Vesicles and update of the MISEV2014 guidelines. J. Extracell. Vesicles. 2018;7:1535750. doi: 10.1080/20013078.2018.1535750. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

The datasets used in the current study might be shared upon reasonable request to Hyun-kyung Cho, MD, PhD.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES