Baseline assessment of staff perception of critical value practices in government hospitals in Kuwait

Talal ALFadhalah 1, Buthaina Al Mudaf 2, Haya Al Tawalah 3,4, Wadha A Al Fouzan 4,5, Gheed Al Salem 6, Hanaa A Alghanim 7, Samaa Zenhom Ibrahim 8, Hossam Elamir 9, Hamad Al Kharji 9,
PMCID: PMC9347105  PMID: 35918679

Abstract

Background

Notification of laboratory-determined critical values is key for effective clinical decision making and is thus a consequential step in a patient’s health care and safety. This study presents an overview of staff reporting policies and procedures concerning critical values in Kuwaiti governmental hospitals.

Methods

A cross-sectional descriptive study design was adopted. Study subjects were affiliated with laboratories from five government hospitals (four general and one sub-specialty hospital). All laboratory staff in every hospital were included. The Statistical Package for the Social Sciences (version 23) was used to analyse the collected data at a significance level of ≤ 0.05. Quantitative data analysis included univariate descriptive (means, medians, standard deviations, frequencies, percentages) and bivariate (chi-squared, ANOVA and Kruskal–Wallis tests) analyses. These analyses provided associations between participating hospitals and staff perceptions towards the policies and procedures surrounding critical values.

Results

559 questionnaires were returned, a total response of 30.5% after those of 79 phlebotomists were excluded (eligible sample size n = 1833). The notification of critical values differs between participated laboratories in delivering protocol and time duration. Linked protocols between laboratories did not exist regarding policies and guidelines for applying the same procedures for critical value notification. There are differences in critical value limits among the participating laboratories.

Conclusion

This study is the first to survey laboratory staff perceptions of critical value practices in Kuwaiti government hospitals. Enhancing critical value reporting and policy is crucial for improving patient safety and to develop high-quality health services. The findings of this study can help policy makers implement future intervention studies to enhance laboratory practices in the area of critical values and improve patient safety and the quality of government hospital systems.

Supplementary Information

The online version contains supplementary material available at 10.1186/s12913-022-08329-z.

Keywords: Kuwait, Hospital Laboratory, Critical values reporting, Hospital practices

Background

Laboratory tests are estimated to influence 70% of medical diagnoses, which is important to acknowledge, as medical errors based on the results of these tests affect patient safety [1]. The "critical values" yielded by these tests are considered important parameters for evaluating patient safety and clinical efficacy [2]. In a seminal paper published 50 years ago, Lundberg first described the concept of the critical value (also known as a "panic value") as a test result significantly outside the normal range that requires immediate action to be taken by caregiving staff to avoid life-threatening consequences [3]. Since then, the idea of critical laboratory values has prevailed in most medical settings. McFarlane et al. [4] recommended that each laboratory should have their own list of critical values and must report when a result falls outside the determined limits. Regrettably, issues of timely notification and not following-up a critical value persist within present health care systems [4, 5]. Furthermore, critical laboratory values are yet to be standardised throughout health care systems, which requires individual health care organisations to decide their own [5, 6]. In 2004, the World Health Organization stated that the reporting of critical laboratory values is a key goal towards patient safety and it is also an important element in many worldwide accreditation programmes [4, 5]. For example, instant notification of a critical laboratory value is required of medical laboratories abiding by ISO 15,189 guidelines [7]. Moreover, the reporting of critical values usually follows strict criteria to avoid complications in doing [2] so; for example, to simplify the notification process, the College of American Pathologists has guidance on policies and procedures for identifying and reporting critical values [8]. Thus far, the process of reporting critical laboratory values is unknown and no documentation is saved or exchanged between the laboratory and the physician in charge [9]. Furthermore, the volume of forgotten call backs from physicians is considered the major challenge confronting laboratory technicians [8]. In Kuwait, it is unknown how the notification of critical laboratory values, the limits of these values and the policies or guidelines that govern their notification are perceived by hospital staff. The current study aimed to assess these perceptions and practices. In particular, it examined staff knowledge about the availability of policies and how to implement them in a notification scenario, and their knowledge regarding critical values limits. The findings of this study should guide policies aimed at improving patient-centred laboratory practices and governmental procedures. Also, the conclusions of this study might lead to increased patient safety and especially a decrease in the number of lethal mistakes arising from practicing the notification of critical values.

Stating the problem

Failures to notify on critical laboratory values affect patient safety, and is considered a medical error that could lead to a life-threatening condition [7]. Having policies and guidelines that instruct how and when to notify of a critical value, is a key element that steers the notification process [8]. The current study investigated the knowledge of laboratory staff about such guidelines and policies in Kuwaiti hospitals.

Significance of research

The current study builds knowledge on the importance to patient safety of the process of critical value notification. Also, by following the policies and guidelines relating to critical value notification, the quality of services will improve services quality, which is expected to lead to a reduction in medical errors.

Research objectives

The broader objectives were to assess staff perceptions about the notification of critical values. Specifically, we aimed to:

  1. Assess the knowledge and attitudes of respondents in government hospitals towards the policies and guidelines relating to the notification of critical values.

  2. Assess the respondents knowledge of critical value limits.

Methods

Study design

A cross-sectional descriptive study design was adopted. The sample population was laboratory staff in the selected hospitals who are eligible for the study.

Study settings and study period

Subjects were affiliated with laboratories from five government hospitals. The study areas comprised four general hospitals, providing predominantly secondary care services, and one sub-speciality hospital, which provides tertiary care. The data took around four months to be gathered.

Research tool

A structured, validated questionnaire was adapted from a published study by Mosallam and Ibrahim [5]. Their questionnaire was divided into seven sections including socio-demographics. The first recorded the characteristics of the partaking hospitals and laboratories. The second section assessed their policies and procedures for reporting critical values, and the third asked about reporting processes. The fourth discussed the way of critical valued documentation and monitoring. The fifth section asked respondents to record ranges of critical values for selected common laboratory tests. Prior final section was asking about any delay in critical values reporting and the reason if that delay applies. The final part of the questionnaire assessed the satisfaction for the critical values reporting process.

The validity of that study tool was assessed by laboratory-setting experts. In our version, the section on socio-demographic characteristics has been modified due to some of the job titles differing. The survey consists of 35 items grouped into seven sections including socio-demographics. The first section focused on the socio-demographic characteristics of the participants. The second section was concerned with the policies and procedures surrounding critical values at participating laboratories. The third section surveyed participants’ practices in reporting critical values to determine, for example, if critical values are communicated immediately upon their identification; also, whether a laboratory technologist or doctor is responsible for actioning the reporting of a critical value if one arises. The fourth section was about how critical values are documented and monitored. The fifth section dealt with critical values for commonly performed tests at the participating hospitals. The sixth section concerned delays in reporting critical values and the reasons for such delays. The final section sought to determine if the participant is satisfied with the process of reporting critical values and if the reporting is subject to delays. Hard copies of the survey in either Arabic (Additional file: Appendix 1) or English (Additional file: Appendix 2) were deployed in the study according to the participant's preference.

Data collection and sampling

A total population sampling technique was used, and a total of 1833 doctors and technicians from the laboratory departments of the five participating Kuwaiti government hospitals were eligible to participate. Same-day permission was obtained from the laboratory head to enter and distribute the questionnaire. This sampling technique involves the entire population (laboratory staff), so we excluded staff whose duties are not relevant to analysis or reporting (phlebotomists) as well as administration staff. The sampling procedure was based on non-probability. The independent variables were policy and guidelines on critical value notification, whereas the dependent variables were knowledge of the practices and critical value limits. The instruments of data collection were the survey forms distributed for completion by each participant at participating hospitals. Data was gathered separately from each hospital and took four months to complete the collection (November 2018 to February 2019).

Operational definition

Definition of variables:

Policy and guidelines Outlines of what to do in any situation involving a laboratory
Knowledge Information about specific practices
Limits Reference ranges for critical values (high and low)
Doctor Laboratory physician
Technician Laboratory staff (non-physician)
Phlebotomist Staff trained in withdrawing blood from patients
Critical values Abnormal limits in laboratory tests ranges

Data analysis and processing

Participant identity and hospitals were coded for anonymity. To be included in the analysis, a returned questionnaire must have had at least one question answered. The Statistical Package for the Social Sciences (SPSS) version 23 was used to analyse the collected data at a significance level of ≤ 0.05. Quantitative data analysis included univariate descriptive (means, medians, standard deviations, frequencies, percentages) and bivariate (chi-square, ANOVA and Kruskal–Wallis tests) analyses.

Results

Five hundred and fifty-nine questionnaires were returned from the five participating hospitals, a total response of 30.5% after those of 79 phlebotomists were excluded (eligible sample size n = 1833).

Hospital statistics and socio-demographic characteristics

The number of beds in the hospitals ranged from 218 to 868, with a total number of 2990 and occupancy rates between 54 and 70%. The total number of laboratory units was 38, with each hospital having between 5 and 14 units of different specialities (e.g., microbiology, biochemistry). Collectively, the hospitals performed a total of more than 25 million tests; individually, the numbers of tests ranged from 1.684 million to 7.441 million. The response rate was 30.5%, just under two-thirds of which were from female participants. More than half of the participants were aged between 30 and 45 years and two-thirds of participants were non-Kuwaiti nationals. Doctors comprised 12% of the respondents. Respondents principally worked in haematology (32.8%), biochemistry (23%) and microbiology (20.2%) units. A comparison of hospitals by laboratory position (e.g., head of unit, senior technician) yielded a p value of 0.01, that is, they differed significantly in terms of the positions held by their participants. Table 1 shows hospital data and socio-demographic characteristics of the participants.

Table 1.

Hospital statistics (2018) and socio-demographic characteristics of participants

Hospital A Hospital B Hospital C Hospital D Hospital E p Total
N % N % N % N % N % N %
Hospital
 Bed number 218 (7.3) 414 (13.8) 868 (29.0) 725 (24.2) 765 (25.6) 2990
 Bed occupancy rate 54% 70% 59% 66% 69% 64.4%
Laboratories
 Unit number 14 (36.8) 6 (15.8) 5 (13.2) 8 (21.1) 5 (13.2) 38
 Staff number
  Doctors 33 (19.5) 26 (12.6) 26 (8.8) 60 (5.9) 26 (11.4) 171 (8.9)
  Technicians 121 (71.6) 169 (81.6) 242 (82.0) 941 (93.0) 189 (82.5) 1662 (86.9)
  Phlebotomists 15 (8.9) 12 (5.8) 27 (9.2) 11 (1.1) 14 (6.1) 79 (4.1)
 Test number (in millions) 1.684 (6.6) 7.441 (29.0) 4.518 (17.6) 6.343 (24.7) 5.698 (22.2) 25.684
Participants
 Response rate 42.2% 46.7% 58.2% 10.0% 68.8% 30.6%
 Gender  < .001
  Male 23 (35.4) 23 (25.3) 69 (44.5) 28 (28.0) 73 (49.3) 216 (38.6)
  Female 42 (64.6) 68 (74.7) 86 (55.5) 72 (72.0) 75 (50.7) 343 (61.4)
 Age .166
  Below 30 years 27 (41.5) 31 (34.1) 34 (21.8) 31 (31.6) 53 (35.8) 176 (31.5)
  30–45 years 31 (47.7) 41 (45.1) 90 (57.7) 53 (54.1) 71 (48.0) 286 (51.3)
  46–55 years 5 (7.7) 9 (9.9) 18 (11.5) 7 (7.1) 16 (10.8) 55 (9.9)
  Over 55 years 2 (3.1) 10 (11.0) 14 (9.0) 7 (7.1) 8 (5.4) 41 (7.3)
 Nationality  < .001
  Kuwaiti 36 (55.4) 47 (51.6) 46 (29.7) 52 (52.0) 17 (11.6) 198 (35.5)
  Non-Kuwaiti 29 (44.6) 44 (48.4) 109 (70.3) 48 (48.0) 130 (88.4) 360 (64.5)
 Profession .002
  Doctor 10 (15.4) 14 (15.6) 5 (3.2) 18 (18.0) 20 (13.6) .378 67 (12.0)
   Assistant register  −   −  1 (7.1)  −   −  5 (27.8) 1 (5.0) 7 (10.4)
   Register 3 (30.0) 3 (21.4) 2 (40.0) 5 (27.8) 11 (55.0) 24 (35.8)
   Senior register 3 (30.0) 3 (21.4) 3 (60.0) 3 (16.7) 3 (15.0) 15 (22.4)
   Specialist 1 (10.0) 3 (21.4)  −   −  3 (16.7) 2 (10.0) 9 (13.4)
   Senior specialist 1 (10.0) 1 (7.1)  −   −  1 (5.6) 2 (10.0) 5 (7.5)
   Consultant 2 (20.0) 3 (21.4)  −   −  1 (5.6) 1 (5.0) 7 (10.4)
  Technician 55 (84.6) 76 (84.4) 151 (96.8) 82 (82.0) 127 (86.4)  < .001 491 (88.0)
   Assistant practitioner 2 (3.6) 5 (6.6) 7 (4.7) 6 (7.4) 8 (6.3) 28 (5.7)
   Practitioner 13 (23.6) 6 (7.9) 5 (3.3) 9 (11.1) 2 (1.6) 35 (7.2)
   Senior practitioner 5 (9.1)  −   −  8 (5.3) 4 (4.9) 4 (3.1) 21 (4.3)
   Assistant technician  −   −  3 (3.9) 10 (6.7) 1 (1.2) 8 (6.3) 22 (4.5)
   Technician 28 (50.9) 37 (48.7) 71 (47.3) 42 (51.9) 85 (66.9) 263 (53.8)
   Senior technician 4 (7.3) 7 (9.2) 21 (14.0) 3 (3.7) 4 (3.1) 39 (8.0)
   Specialist 3 (5.5) 9 (11.8) 10 (6.7) 6 (7.4) 7 (5.5) 35 (7.2)
   Senior specialist  −   −  9 (11.8) 18 (12.0) 10 (12.3) 9 (7.1) 46 (9.4)
 Position .010
  Head of department 3 (4.8) 1 (1.1) 1 (0.7)  −   −   −   −  5 (0.9)
  Head of unit 2 (3.2) 3 (3.4) 2 (1.3)  −   −  4 (2.8) 11 (2.0)
  Laboratory doctor 6 (9.5) 10 (11.2) 4 (2.7) 15 (15.6) 16 (11.1) 51 (9.4)
  Head of laboratory technicians 2 (3.2) 4 (4.5) 6 (4.0) 3 (3.1) 2 (1.4) 17 (3.1)
  Technician 50 (79.4) 71 (79.8) 137 (91.3) 78 (81.3) 122 (84.7) 458 (84.5)
 Unit  < .001
  Microbiology  −   −  19 (20.9) 35 (24.1) 20 (20.0) 37 (25.0) 111 (20.2)
  Hematology 1 (1.5) 31 (34.1) 50 (34.5) 42 (42.0) 56 (37.8) 180 (32.8)
  Biochemistry 11 (16.9) 27 (29.7) 44 (30.3) 1 (1.0) 43 (29.1) 126 (23.0)
  Histopathology 13 (20.0) 6 (6.6) 10 (6.9) 17 (17.0) 5 (3.4) 51 (9.3)
  Immunology 16 (24.6)  −   −   −   −  11 (11.0)  −   −  27 (4.9)
  Virology 15 (23.1)  −   −  6 (4.1) 9 (9.0) 7 (4.7) 37 (6.7)
  Molecular genetics 9 (13.8)  −   −   −   −   −   −   −  9 (1.6)
  Reception  −   −  8 (8.8)  −   −   −   −   −  8 (1.5)

N: Valid responses %: Percentage p: p-value (Statistically significant at p ≤ .05, highly significant at p ≤ .001

Critical value policies and procedures

In completing the statement "Critical values reporting is…", 88.4% of respondents viewed it as "an essential procedure", 7.6% selected "somewhat important" and 4.1% thought it a "minor policy". The hospital best representing that view is hospital D at 7.2% (the most for minor) and hospital E (the most for essential) at 93.2%. Across the five hospitals, 89.5% confirmed the presence of a written procedure for the reporting of critical values, and 86.6% stated that a comprehensive list of critical values exists in their setting. The number of tests in those lists ranged from 0 to 90, with a mean of 12.67 and median of 10, but were not significantly different between the hospitals. Across the five hospitals, 32.1% of participants stated that critical value list was developed based on “medical society recommendations”. Overall, this was the most popular response, but not representative of every hospital, from which differences in response were highly significant. However, a total of 69 individuals (12.3%) gave no reason for how the critical value list was developed; at the single-hospital level, this number varied between 1 (hospital E) and 21 (hospital C). The percentage of laboratory personnel trained in reporting critical values differed significantly between hospitals but was nonetheless high; overall the proportion was greater than 92%. Furthermore, the hospitals were shown to be highly significantly different in their updating of procedures related to critical values; overall, 85.5% of respondents said their laboratory did so. Overall, 63.6% and 41.4% of respondents confirmed their laboratories held “unique ranges for distinct populations" by age and diagnosis, respectively; both sets of responses differed highly significantly between hospitals (p < 0.001). The lowest percentage response confirming unique ranges for distinct populations by diagnosis was from hospital B (32.5%) and the highest goes to hospital E at 47.9% according to the responses. Overall, 84.4% of respondents indicated their laboratory had a policy for assessing the timeliness of reporting and differences between hospitals were highly significant. Across all settings, 87.9% of respondents indicated their laboratory had a policy for managing the repetition of critical values and differences between hospitals were significant. The existence of a read-back policy for reported critical values was indicated by 78.8% of all respondents and differences between hospitals were highly significant; hospital B gave the highest percentage (92%) of positive responses to this question. Table 2 shows the responses on policies and procedures pertaining to critical values.

Table 2.

Critical value policies and procedures at participating laboratories

Hospital A Hospital B Hospital C Hospital D Hospital E p Total
n (%) n (%) n (%) n (%) n (%) n (%)
Critical values reporting is .026
 Minor policy 2 (3.3) 1 (1.1) 7 (4.6) 7 (7.2) 5 (3.4) 22 (4.1)
 Somewhat important 8 (13.3) 9 (10.2) 16 (10.5) 3 (3.1) 5 (3.4) 41 (7.6)
 An essential procedure 50 (83.3) 78 (88.6) 129 (84.9) 87 (89.7) 136 (93.2) 480 (88.4)
Presence of written procedures for critical value reporting 53 (82.8) 80 (89.9) 138 (90.2) 83 (83) 142 (95.9) .011 496 (89.5)
Presence of a comprehensive list of critical values 41 (69.5) 76 (84.4) 137 (89.0) 74 (79.6) 142 (96.6)  < .001 470 (86.6)
Number of tests in the list
 Range 0–32 4–50 1–30 2–90 3–25 0–90
 Mean ± SD 13.92 ± 10.26 15.02 ± 7.06 12.28 ± 7.34 12.02 ± 16.50 11.76 ± 7.20 .237 12.67 ± 9.36
 Median 15.5 16 10 5 9 10
Critical value list was developed based on
 Published literature 17 (26.2) 26 (28.6) 26 (16.7) 21 (21.0) 26 (17.6) .134 116 (20.7)
 Opinion of clinicians 10 (15.4) 32 (35.2) 14 (9.0) 30 (30.0) 47 (31.0)  < .001 133 (23.2)
 Medical societies' recommendations 9 (13.8) 37 (40.7) 35 (22.4) 30 (30.0) 69 (46.0)  < .001 180 (32.1)
 Manufacturer's recommendations 3 (4.6) 9 (9.9) 14 (9.0) 16 (16.0) 10 (6.8) .084 52 (9.3)
 Review of laboratory practice 20 (30.8) 38 (41.8) 54 (34.6) 21 (21.0) 32 (21.6) .002 165 (29.5)
 Informal laboratory peer review 6 (9.2) 10 (11.0) 3 (1.9) 4 (4.0) 2 (1.4) .001 25 (4.5)
 Others 7 (10.8) 2 (2.2) 10 (6.4) 1 (1.0) 11 (7.4) .032 31 (5.5)
 No answers 16 (24.6) 13 (14.3) 21 (13.5) 18 (18.0) 1 (0.7)  < .001 69 (12.3)
Laboratory personnel trained on reporting critical values 52 (83.9) 85 (94.4) 144 (93.5) 87 (88.8) 140 (95.2) .046 508 (92.2)
Critical values procedures are regularly updated 49 (79.0) 78 (89.7) 118 (77.6) 79 (82.3) 141 (95.9)  < .001 465 (85.5)
Unique ranges for distinct population by age 14 (22.2) 66 (73.3) 111 (72.5) 52 (54.2) 105 (72.4)  < .001 348 (63.6)
Unique ranges for distinct population by diagnosis 23 (35.4) 26 (32.5) 59 (40.4) 44 (44.9) 68 (47.9) .001 220 (41.4)
Policy for assessing timeliness of reporting 59 (90.8) 70 (79.5) 113 (74.3) 87 (88.8) 135 (91.8)  < .001 464 (84.4)
Policy on how to manage the repetition of critical values 51 (79.7) 75 (90.4) 136 (87.7) 82 (84.5) 135 (92.5) .002 479 (87.9)
Laboratory policy requires read back 20 (35.7) 81 (92.0) 123 (80.4) 72 (75.0) 127 (88.2)  < .001 423 (78.8)

N Number, % Percentage, SD Standard deviation

Multiple responses were allowed

p: p value (statistically significant if p ≤ .05, highly significant if p ≤ .001)

Participants’ practices and reporting

The vast majority of participants (91.6%) across all the hospitals reported that wholly critical values are communicated immediately as they arise. In most of the hospitals, the consensus was that a laboratory technician is responsible for alerting the relevant caregiver when a patient presents a critical value, although there was a highly significant difference (p < 0.001) between them. Overall, 62.9% of the total number of participants agreed. According to the overall response, the physician ordering the test (63.7%) and nurses (60.5%) are those most likely to receive the calls. Moreover, critical value reporting in the surveyed hospitals showed highly statistically significant differences with respect to physician ordering the test, nurses and any physician on call. Critical values are reported to the caregiver mainly by telephone, as the majority (65.7%) of respondents indicated. Hospitals showed statistically significant differences (p = 0.032) in their use of wireless technologies to report critical values; overall, 33.1% of participants indicated this was in use in their setting. A high percentage (91.3%) of respondents across the hospitals reported the re-testing of critical values before verification, but with highly significant differences (p < 0.001) between the hospitals. For sample re-testing, the person who is responsible for drawing the sample is contacted to verify the validity of it. A total of 58.4% of respondents confirmed this was procedure at their setting, and there were statistically highly significant differences between the hospitals. The usual practice in handling repeated critical values from the same patient is to report initial critical value and every subsequent critical value, as confirmed by 44.6% of responses, with high significant differences between hospitals. Approximately half (51.2%) of respondents indicated that critical laboratory values are documented in a computer system, written on the result form and documented in the laboratory register. Across all hospitals, 49.8% of surveyed staff stated that when documenting a verbal communication on a log, all information was included (e.g., patient identity, sender identity). The percentage of participants indicating that their setting measured the time from the result becoming available to notification of the caregiver responsible varied significantly between hospitals; across all settings, the percentage was 72.2%. There are many reasons for delaying the reporting of critical values, but approximately 42.5% of respondents across all hospitals claimed that the main issue is the health care provider's contact information being unavailable. Of all the hospital staff surveyed, 86.8% were satisfied with the way critical laboratory values are reported, although the differences between hospitals were statistically significant. The average time for a responsible caregiver to be notified with a test result can differ depending on the shift. In the morning shift, this time ranges between 0 and 4320 min. In the evening, the range is 0 to 2880 min and in the night shift the range is 0 to 1440 min. Differences in notification time during the morning and evening shifts were statistically significant between the hospitals. Table 3 shows the surveyed data regarding critical value reporting practices (participants were allowed to give multiple responses to some of the questions).

Table 3.

Participants’ Practices and Attitude Towards Critical Value Reporting

Hospital A Hospital B Hospital C Hospital D Hospital E p Total
n (%) n (%) n (%) n (%) n (%) n (%)
Communicate critical values immediately upon their identification 51 (83.6) 80 (92.0) 144 (93.5) 86 (86.9) 140 (95.9) .036 501 (91.6)
Person responsible for making the call
 Senior staff 15 (23.1) 54 (59.3) 73 (46.8) 43 (43.0) 79 (53.4)  < .001 264 (47.1)
 Laboratory technician 16 (24.6) 70 (76.9) 97 (62.2) 67 (67.0) 102 (68.9)  < .001 352 (62.9)
 Others 41 (63.1) 19 (20.9) 22 (14.1) 24 (24.0) 32 (21.6)  < .001 138 (24.6)
 No answers 5 (7.7) 3 (3.3) 3 (1.9) 4 (4.0) 1 (0.7) .053 16 (2.9)
Person who receives the call
 Physicians ordering the test 42 (64.6) 57 (62.6) 92 (59.0) 52 (52.0) 114 (77.0) .001 357 (63.7)
 Nurses 25 (38.5) 72 (79.1) 73 (46.8) 59 (59.0) 110 (74.3)  < .001 339 (60.5)
 Any physician on call 28 (43.1) 42 (46.2) 40 (25.6) 39 (39.0) 82 (55.4)  < .001 231 (41.3)
 Any people working on the ward 7 (10.8) 11 (12.1) 14 (9.0) 15 (15.0) 9 (6.1) .201 56 (10.0)
 Others 4 (6.2) 6 (6.6) 7 (4.5) 2 (2.0) 3 (2.0) .252 22 (3.9)
 No answers 5 (7.7) 1 (1.1) 3 (1.9) 5 (5.0) 1 (0.7) .021 15 (2.7)
Critical values are reported to the caregiver mainly by
 Sending test report to ward 28 (43.1) 36 (39.6) 36 (23.1) 33 (33.0) 22 (14.9)  < .001 155 (27.7)
 Telephone 40 (61.5) 57 (62.6) 95 (60.9) 55 (55.0) 121 (81.8)  < .001 368 (65.7)
 Computer 11 (16.9) 34 (37.4) 49 (31.4) 54 (54.0) 57 (38.5)  < .001 205 (36.6)
 Direct contact with requesting physician 34 (52.3) 20 (22.0) 74 (47.4) 33 (33.0) 34 (23.0)  < .001 195 (34.8)
 Fax 0 (0.0) 0 (0.0) 1 (0.6) 1 (1.0) 0 (0.0) .855 2 (0.4)
 All tools 10 (15.4) 28 (30.8) 15 (9.6) 24 (24.0) 14 (9.5)  < .001 91 (16.3)
 No answers 8 (12.3) 1 (1.1) 2 (1.3) 1 (1.0) 1 (0.7)  < .001 13 (2.3)
Wireless technologies used to report critical values 18 (29.5) 31 (35.2) 52 (34.2) 42 (43.8) 36 (25.0) .032 179 (33.1)
Re-testing for critical values verification 49 (80.3) 81 (92.0) 152 (97.4) 79 (79.8) 141 (96.6)  < .001 502 (91.3)
In sample re-testing, the person responsible for drawing the sample contacted to verify the validity of drawing the sample 25 (43.1) 51 (61.4) 102 (66.7) 55 (59.1) 77 (53.5)  < .001 310 (58.4)
In case of handling repeat critical values from the same patient, the usual practice is to:  < .001
 Report initial critical value and all subsequent critical values, regardless of previous results 25 (49.0) 36 (42.4) 59 (41.0) 36 (40.0) 68 (51.5) 224 (44.6)
 Report worsening values, values that were "grossly different" from previous values, and values that moved in and out 5 (9.8) 29 (34.1) 23 (16.0) 27 (30.0) 37 (28.0) 121 (24.1)
 Report repeated critical values once per interval of time 21 (41.2) 20 (23.5) 62 (43.1) 27 (30.0) 27 (20.5) 157 (31.3)
Reported critical laboratory values are documented:
 In the computer system 15 (23.1) 31 (34.1) 56 (35.9) 38 (38.0) 45 (30.4) .276 185 (33.0)
 Written on the result form 8 (12.3) 19 (20.9) 24 (15.4) 12 (12.0) 21 (14.2) .457 84 (15.0)
 Documented in the laboratory register 14 (21.5) 23 (25.3) 45 (28.8) 19 (19.0) 30 (20.3) .311 131 (23.4)
 All of the above 39 (60.0) 43 (47.3) 73 (46.8) 48 (48.0) 84 (56.8) .197 287 (51.2)
 It is not documented 0 (0.0) 2 (2.2) 0 (0.0) 2 (2.0) 1 (0.7) .205 5 (0.9)
 No answers 6 (9.2) 1 (1.1) 4 (2.5) 0 (0.0) 3 (2.0) .010 14 (2.5)
In case of documenting verbal communication on a log, the following is included:
 Identification of patient 13 (20.0) 28 (30.8) 65 (41.7) 37 (37.0) 33 (22.3) .001 176 (31.4)
 Identification of sender 3 (4.6) 7 (7.7) 14 (9.0) 11 (11.0) 9 (6.1) .521 44 (7.9)
 Identification of recipient (person receiving the report) 6 (9.2) 19 (20.9) 31 (19.9) 23 (23.0) 22 (14.9) .139 101 (18.0)
 Critical test result reported 10 (15.4) 20 (22.0) 53 (34.0) 19 (19.0) 21 (14.2)  < .001 123 (22.0)
 Date and time of reporting 11 (16.9) 22 (24.2) 51 (32.7) 25 (25.0) 31 (20.9) .074 140 (25.0)
 All information 31 (47.7) 47 (51.6) 55 (35.3) 47 (47.0) 99 (66.9)  < .001 279 (49.8)
 No answers 16 (24.6) 6 (6.6) 25 (16.0) 7 (7.0) 5 (3.4)  < .001 59 (7.9)
The time from result availability to the responsible caregiver notification is measured 39 (63.9) 60 (69.0) 112 (75.7) 65 (69.1) 111 (76.0) .025 387 (72.2)
Reasons for delay in reporting critical values:
 Getting someone to accept the results 20 (30.8) 49 (53.8) 48 (30.8) 21 (21.0) 30 (20.3)  < .001 168 (30.0)
 Reporting critical values to the physician responsible for the patient 15 (23.1) 46 (50.5) 52 (33.3) 16 (16.0) 23 (15.5)  < .001 152 (27.1)
 Knowing the name of the assigned physician 7 (10.8) 29 (31.9) 19 (12.2) 12 (12.0) 30 (20.3) .001 97 (17.3)
 Provider contact information is not available 24 (36.9) 54 (59.3) 48 (30.8) 39 (39.0) 73 (49.3)  < .001 238 (42.5)
 The person receiving the result is unwilling to read it back to ensure that it is correct 5 (7.7) 14 (15.4) 15 (9.6) 10 (10.0) 24 (16.2) .294 68 (12.1)
 List of critical values is too long 0 (0.0) 5 (5.5) 6 (3.8) 2 (2.0) 4 (2.7) .450 17 (3.0)
 Reporting critical results disrupts the workflow 0 (0.0) 19 (20.9) 8 (5.1) 6 (6.0) 12 (8.1)  < .001 45 (8.0)
 Discharged patients at the time of reporting the result 11 (16.9) 41 (45.1) 49 (31.4) 35 (35.0) 51 (34.5) .046 187 (33.4)
 There are no difficulties 15 (23.1) 4 (4.4) 36 (23.1) 33 (33.0) 28 (18.9)  < .001 116 (20.7)
 No answers 17 (26.2) 7 (7.7) 14 (9.0) 8 (8.0) 12 (8.1) .001 58 (10.4)
There is a delay in reporting critical laboratory values 4 (7.0) 22 (25.9) 31 (20.8) 12 (12.6) 29 (21.0) .112 98 (18.7)
Satisfied with the way a staff would report critical laboratory values 42 (73.7) 75 (86.2) 132 (86.8) 81 (84.4) 129 (93.5) .002 459 (86.6)
The average time from result availability to the responsible caregiver notification in each of the following shifts
 Morning shift
  Range 0 – 600 10 – 4320 0 – 120 5 – 2880 0 – 1440 0 – 4320
  Mean ± SD 150.21 ± 760.53 153.13 ± 760.53 26.89 ± 28.66 303.54 ± 795.09 78.08 ± 250.62 .048 104.55 ± 408.16
  Median 120 10 30 60 30 30
 Evening shift
  Range 0 – 2880 10 – 60 0 – 120 5 – 120 0 – 1440 0 – 2880
  Mean ± SD 447.5 ± 765.82 19 ± 15.94 19.58 ± 27.08 61.25 ± 46.11 77.28 ± 250.43  < .001 94.44 ± 317.18
  Median 120 10 10 30 30 30
 Night shift
  Range 0 – 120 10 – 60 0 – 120 5 – 120 0 – 1440 0 – 1440
  Mean ± SD 83.21 ± 51.8 18.33 ± 14.99 21.94 ± 29.8 61.25 ± 46.11 77.28 ± 250.43 .389 60.36 ± 191.45
  Median 120 10 5 30 30 30

n: Correct responses (%): Percentage SD: Standard deviation

Multiple responses are allowed

p: p-value (Statistically significant at p ≤ .05, highly significant at p ≤ .001)

Commonly performed tests critical values

For some of the tests, there are differences in the ranges adopted by the hospitals. None of the participating individuals correctly identified the upper limits of the phosphorus, creatinine and prothrombin time (PT) tests. For the majority of the tests, differences in staff knowledge between the hospitals were statistically significant. The reported tests showed slight differences in critical values range between all hospitals. Table 4 lists the tests commonly performed in hospitals and their critical values according to hospital guidelines.

Table 4.

Critical Values for Tests Commonly Performed at Participating Hospitals

Hospital A Hospital B Hospital C Hospital D Hospital E p Total
V N n % V N n % V N n % V N n % V N n % N n %
Potassium
 Lower Limit 2.5 1 0 0.0 2.5 27 25 92.6 2.8 15 1 6.7 2.5 4 0 0.0 2.8 37 34 91.9  < .001 84 60 71.0
 Upper Limit 6.6 1 0 0.0 6.5 27 25 92.6 6.2 14 3 21.4 6.5 4 0 0.0 6.5 38 36 94.7  < .001 84 64 76.2
 Unit mmol/L 2 2 100 mmol/L 24 24 100 mmol/L 31 30 96.8 mmol/L 2 2 100 mmol/L 45 45 100 .566 104 103 99.0
Sodium
 Lower Limit 120 1 1 100 120 27 25 92.6 120 14 11 78.6 120 4 0 0.0 120 38 34 89.5 .001 84 71 84.5
 Upper Limit 160 1 1 100 160 27 25 92.6 160 14 11 78.6 160 4 0 0.0 160 38 36 94.7  < .001 84 73 86.9
 Unit mmol/L 2 2 100 mmol/L 23 23 100 mmol/L 31 23 74.2 mmol/L 2 2 100 mmol/L 45 45 100 .001 103 95 92.2
Magnesium
 Lower Limit 0.4 1 0 0.0 0.4 25 24 96.0 0.5 12 11 91.7 0.4 2 0 0.0 0.5 36 36 100  < .001 76 71 93.4
 Upper Limit None 0 0 0.0 3.7 25 24 96.0 1.9 12 1 8.3 None 0 0 0.0 1.9 37 34 91.9  < .001 74 59 79.7
 Unit mmol/L 2 2 100 mmol/L 23 23 100 mmol/L 30 19 63.3 mmol/L 2 2 100 mmol/L 43 43 100  < .001 100 89 89.0
Calcium
 Lower Limit 1.65 1 0 0.0 1.5 27 25 92.6 1.5 14 3 21.4 1.8 3 0 0.0 1.5 37 36 97.3  < .001 82 64 78.0
 Upper Limit 3.25 1 1 100 3.5 27 24 88.9 3.2 15 1 6.7 3.5 2 0 0.0 3.2 37 36 97.3  < .001 82 62 75.6
 Unit mmol/L 1 1 100 mmol/L 24 24 100 mmol/L 29 18 62.1 mmol/L 2 2 100 mmol/L 43 43 100  < .001 99 88 88.9
Phosphorous
 Lower Limit 0.32 1 1 100 0.36 23 22 95.7 None 0 0 0.0 0.3 0 0 0.0 None 0 0 0.0  > .999 24 23 95.8
 Upper Limit None 0 0 0.0 None 0 0 0.0 None 0 0 0.0 2.9 0 0 0.0 None 0 0 0.0 0 0 0.0
 Unit mmol/L 2 2 100 mmol/L 20 20 100 None 0 0 0.0 mmol/L 0 0 0.0 None 0 0 0.0 22 22 100
Bilirubin
 Upper Limit None 0 0 0.0 340 25 23 92.0 239 14 2 14.3 25 2 1 50.0 299 17 1 5.9  < .001 58 27 46.6
 Unit None 0 0 0.0 µmol/L 23 0 0.0 mmol/L 23 6 26.1 µmol/L 1 0 0.0 mmol/L 25 22 88.0  < .001 72 28 38.9
BUN
 Upper Limit None 0 0 0.0 R 0 0 0.0 None 0 0 0.0 None 0 0 0.0 28.56 28 19 67.9 28 19 67.9
 Unit None 0 0 0.0 R 0 0 0.0 None 0 0 0.0 None 0 0 100 mmol/L 28 26 92.9 28 26 92.9
Creatinine
 Upper Limit 650 1 0 0.0 None 0 0 0.0 None 0 0 0.0 350 3 0 0.0 None 0 0 0.0 4 0 0.0
 Unit µmol/L 2 2 100 None 0 0 0.0 None 0 0 0.0 µmol/L 1 0 0.0 None 0 0 0.0 .333 3 2 66.7
PH
 Lower Limit None 0 0 0.0 R 0 0 0.0 7.2 7 0 0.0 None 0 0 25.0 7.2 35 29 82.9  < .001 42 29 69.0
 Upper Limit None 0 0 0.0 R 0 0 0.0 7.5 7 6 85.7 None 0 0 0.0 7.6 35 25 71.4 .654 42 31 73.8
PO2
 Lower Limit None 0 0 0.0 R 0 0 0.0 6.33 7 0 0.0 None 0 0 0.0 5.32 35 29 82.9  < .001 42 29 69.0
 Unit None 0 0 0.0 R 0 0 0.0 Kpa 15 6 40.0 None 0 0 0.0 Kpa 28 28 100  < .001 43 34 79.1
PCO2
 Lower Limit None 0 0 0.0 R 0 0 0.0 2.66 7 6 85.7 2.5 0 0 0.0 2.66 35 34 97.1 .309 42 40 95.2
 Upper Limit None 0 0 0.0 R 0 0 0.0 8.30 7 0 0.0 8.9 0 0 0.0 8.00 34 33 97.1  < .001 41 33 80.5
 Unit None 0 0 0.0 R 0 0 0.0 Kpa 15 6 40.0 Kpa 1 1 100 Kpa 32 32 100  < .001 48 39 81.3
Bicarbonate
 Lower Limit None 0 0 0.0 10 19 18 94.7 10 11 10 90.9 10 0 0 0.0 10 31 31 100 .242 61 59 96.7
 Upper Limit None 0 0 0.0 40 20 19 95.0 40 11 10 90.9 40 0 0 0.0 40 30 29 96.7 .755 61 58 95.1
 Unit None 0 0 0.0 mmol/L 19 19 100 mmol/L 19 17 89.5 mmol/L 1 1 100 mmol/L 29 26 89.7 .537 68 63 92.6
Neutrophil
 Lower Limit 1 0 0 0.0 0.5 8 7 87.5 1 5 0 0.0 1 15 11 73.3 None 0 0 0.0 .004 28 18 64.3
 Unit 109/L 1 0 0.0 109/L 8 7 87.5 109/L 24 6 25.0 109/L 11 10 90.0 None 0 0 0.0  < .001 44 23 52.3
Hemoglobin
 Lower Limit 70 1 1 100 70 11 1 9.1 60 13 4 30.8 6.5 26 2 7.7 60 8 4 50.0 .010 59 12 20.3
 Upper Limit None 0 0 0.0 190 12 8 66.7 200 13 3 23.1 20 27 1 3.7 200 8 4 50.0  < .001 60 16 26.7
 Unit g/L 1 1 100 g/L 24 22 91.7 g/L 51 51 100 g/L 11 11 100 g/L 57 49 86 .033 144 134 93.1
Platelet
 Lower Limit 50 1 1 100 20 3 1 33.3 30 13 0 0.0 20 26 7 26.9 20 14 12 85.7  < .001 57 21 36.8
 Upper Limit None 0 0 0.0 1000 9 0 0.0 1500 14 0 0.0 1000 25 19 76.0 1500 14 13 92.9  < .001 62 32 51.6
 Unit (109/L) 109/L 1 0 0.0 109/L 25 19 76.0 109/L 44 14 31.8 1012/L 10 0 0.0 109/L 54 0 0.0  < .001 124 33 26.6
aPTT
 Upper Limit 100 0 0 0.0 120 0 0 0.0 70 7 0 0.0 120 20 8 40.0 70 3 0 0.0 .110 30 8 26.7
 Unit Sec 1 1 100 Sec 24 19 79.2 Sec 30 30 100 Sec 23 13 56.5 Sec 53 53 100  < .001 131 116 88.5
PT
 Upper Limit None 0 0 0.0 None 0 0 0.0 20 3 0 0.0 None 0 0 0.0 20 2 0 0.0 5 0 0.0
 Unit None 0 0 0.0 None 0 0 0.0 Sec 25 22 88.0 None 0 0 0.0 Sec 56 55 98.2 .085 81 77 95.1
INR
 Upper Limit 5 0 0 0.0 6.0 1 0 0.0 None 0 0 0.0 4.5 22 9 40.9 3 1 1 100  > .999 24 9 37.5

V: Critical values as per hospital policy, N: Valid responses, n: Correct responses, %: Percentage of correct responses

aPTT Activated partial thromboplastin time, PT Prothrombin time, INR International normalisation ratio, Sec Seconds

R Retired (Critical value was removed from lab policy), p: p-value (statistically significant if p ≤ .05, highly significant if p ≤ .001)

Comparing the three outcomes based on socio-demographic groups

Regarding the upper and lower limits of critical values and their units, the hospitals showed highly significant statistical differences, but respondents from hospitals B and E gave the most correct answers. Satisfaction with the way staff report critical values was subject to significant difference between hospitals. Individuals from haematology and biochemistry units gave the most correct critical values and units, and differences between the units were highly significant differences (p < 0.001). The data revealed a statistically significant difference (p = 0.015) between gender in the perception of delays in the reporting of critical laboratory values. There is a statistically significant difference associated with age group regarding correct answers of limits and units for critical values. In addition, highly statistically significant differences for all scenarios were observed for nationality, and different professions also plays a role in total. In addition, the different types of doctor showed statistically significant differences in laboratory critical values when reporting is delayed whereas technicians in regards to the responses showed satisfaction with the way critical values are reported. Furthermore, positions did not show any significant difference in regards to limits and units, whereas delays and satisfaction in reporting were subject to statistically significant differences (p = 0.049 and 0.001, respectively). Finally, views on the delay in critical value reporting when compared to limits and units, showed a statistically significant difference. A highly significant statistical difference was found between satisfaction in reporting critical laboratory values and perception of delays. A statistically significant difference was found between satisfaction with reporting procedures and the limits and units assessment. Table 5 shows a comparison between socio-demographic groups in regards to three scenarios.

Table 5.

Comparison between socio-demographic groups in regards to three outcomes

Correct answers of upper and lower limits and units of critical values There is a delay in reporting critical laboratory values Satisfied with the way a staff would report critical laboratory values
Median (IQR) p Yes No I don’t know p Yes No I don’t know p
Hospital  < .001 .112 .002
 A 0.0 (0) 4 49 4 42 8 7
 B 2.0 (12) 22 57 6 75 4 8
 C 0.0 (3) 31 106 12 132 16 4
 D 0.0 (1) 12 76 7 81 9 6
 E 3.0 (12.75) 29 103 6 129 8 1
Unit  < .001 .090  < .001
 Microbiology 0.0 (0) 22 77 9 96 9 5
 Hematology 3.0 (4) 38 124 6 155 11 3
 Biochemistry 7.0 (18) 19 91 8 107 9 3
 Histopathology 0.0 (0) 10 29 7 29 8 10
 Immunology 0.0 (0) 1 22 2 18 4 3
 Virology 0.0 (0) 6 31 0 33 3 1
 Molecular genetics 0.0 (0) 0 5 0 5 0 0
 Reception 0.0 (0) 1 5 1 6 0 1
Gender .094 0.015 .462
 Male 0.0 (3) 27 162 9 177 16 7
 Female 0.0 (5) 70 229 26 281 29 19
Age .006 .085 .123
 Below 30 years 0.0 (3) 41 113 12 151 9 8
 30–45 years 0.0 (3) 43 209 21 227 31 17
 46–55 years 1.0 (4) 10 36 2 44 4 1
 Over 55 years 3.0 (6) 4 32 0 36 1 0
Nationality  < .001  < .001  < .001
 Kuwaiti 0.0 (5) 43 121 23 142 30 17
 Non-Kuwaiti 0.0 (2) 55 269 11 315 15 9
Profession  < .001 .030  < .001
Doctor 0.0 (1) .099 6 46 8 .002 40 12 8 .730
  Assistant register 0.0 (0) 2 2 3 3 2 2
  Register 0.0 (1) 0 21 3 17 4 3
  Senior register 0.0 (4) 1 12 2 11 3 1
  Specialist 0.0 (2) 0 7 0 3 2 2
  Senior specialist 0.0 (0) 0 3 0 3 0 0
  Consultant 2.0 (7) 3 1 0 3 1 0
Technician 0.0 (4) .278 92 343 27 .475 417 33 18 .039
  Assistant practitioner 0.0 (11.25) 2 24 2 27 0 1
  Practitioner 0.0 (2) 4 27 3 29 3 2
  Senior practitioner 0.0 (3) 4 13 2 14 4 2
  Assistant technician 0.0 (3.75) 9 12 1 19 3 0
  Technician 0.0 (4) 50 180 13 228 12 7
  Senior technician 3.0 (7) 8 27 2 30 6 1
  Specialist 0.0 (3) 7 26 1 31 2 2
  Senior specialist 0.5 (3) 7 34 3 38 3 3
Position .116 .049  < .001
 Head of department 0.0 (6) 1 4 0 3 2 0
 Head of unit 0.0 (2) 2 6 0 6 1 1
 Laboratory doctor 0.0 (1) 3 37 8 32 9 7
 Head of laboratory technicians 0.0 (2) 5 9 1 10 3 2
 Technician 0.0 (4) 86 320 26 395 26 16
There is a delay in reporting critical laboratory values .049  < .001
 Yes 0.0 (4) 75 17 6
 No 0.0 (4) 362 21 8
 I don’t know 0.0 (4) 17 6 12
Satisfied with the way a staff would report critical laboratory values .001
 Yes 0.0 (4)
 No 0.0 (2)
 I don’t know 0.0 (0)

IQR Interquartile range, p: p-value (statistically significant if p ≤ .05, highly significant if p ≤ .001)

Discussion

Measuring and reporting critical values in the laboratory plays a large clinical role in patient safety and well-being [10]. On that basis, timeframes for the reporting of critical values should be set by each laboratory in consultation with clinicians whether laboratory doctors or other departments physicians [11]. In our study, we estimate the average number of critical value notifications in a one-year period is between 126,000 and 3,600,000, according to studies from China and India [12, 13]. The current study showed that approximately 88% of staff participating considered critical value notification as an essential procedure to practice when an alarming value arises. Many schemes for the accreditation of medical laboratory policies and practices consider the communication of critical values as essential [14], and our respondents seem to agree. Notification is usually ineffective when contacting the responsible physician by telephone [15]. Telephone notification has advantages according to AlSadah et al. [8], such as affording the opportunity to read back the results with immediate explanation, if needed, to minimise errors. Our study revealed that two-thirds of our responses declared using the telephone for critical values reporting, further studies should be done to ensure the control of reporting time and reducing communication errors. Nonetheless, wireless technologies nowadays play a large role in many ways, including critical value notification and reporting, but only around one-third of responses to our survey indicated the use of these technologies to deliver the notification which is not matching subsequent study. A study in India [16] suggested that increased usage of wireless technology in laboratories will improve quality metrics including turnaround time.

To ensure good critical value reporting, the existence of a written procedure for reporting and a comprehensive list of critical values should aid communication [17]. Around 90% of respondents claimed to know of the former, which is a good indication that good reporting is practiced. Before reporting any critical value, the sample should be checked for potential quality issues, for example, by serum or anticoagulated plasma clotting time [18]. Around 87% responses indicated knowledge that a comprehensive list existed, which might acknowledge the importance of critical value notification. Reporting critical values according to a written protocol will address quality assurance and avoid tests reference ranges errors [16]. Medical societies—usually guided by medical professionals representing a particular specialised field—play a role in keeping their community informed about the latest research and developments in that field; following their recommendations aims to ensure that patients receive the best treatment available [19]. According to our results, 32.1% of surveyed staff indicated that medical society recommendations were followed for developing critical value lists in their setting. Consistent with an earlier study, low percentages of responses indicated that critical value lists are based on published literature (21%) and clinician’s opinions (23%). Our prior results showed low knowledge about the policies and guidelines relating to the practice of critical value notification. Having a policy for assessing the timeliness (time frame requires fast response) of critical value reporting is crucial for improvement of patient care [20], and around 84% of respondents indicated their setting had such a policy in place. Notification time has been described by Lippi and Mattiuzzi as an indicator of the quality of patient safety [14]. A study by Piva et al. [21] stated that both technicians and laboratory physicians are responsible for the notification of critical values, whereas in the hospitals we surveyed, technicians are the members of staff who perform the notification of any critical value by around 63% of responses. Usually, the physician who ordered the tests will receive the critical value notification, If they are unavailable, a nurse will receive it, and finally, if necessary, any physician on call [8]. Our findings mirrored this, showing that the physician ordering the test (63%), nurses (60%) and any physician on call (41%) receive the notification. According to a study by Clavijo et al. [22], the hierarchical notification system (with nurses excluded) is time dependent, which means there is a specified time in which to notify the responsible physician. If they cannot be reached, the next in charge should be notified. Widespread knowledge about critical value communication upon identification made a significant difference with notification practices in this study, approximately 92% of participating hospital staff stated they notify immediately. Each laboratory has their own policy for reporting critical values [23]. Approximately 45% of survey participants indicated that all critical values from a patient, including repeat measurements, are reported, which roughly matches the current study. The documenting of critical value reporting is required by the joint commission and other institutes [24]. All documentation is done for the purposes of quality monitoring, including notification time measurements, as reported by Piva et al. [21]. According to former study, approximately half of responses indicated the use of three different documentation methods. An intervention study by Bhartia et al. [25] aimed at improving the quality of critical value reporting recommended, sharing delayed reports with responsible caregiver to avoid future obstacles between technologists and physicians. Furthermore, prior studies reported delays in reporting critical values; thus, solving the problem of delayed reporting will improve the quality of the service. Less than 19% of responses to our survey confirmed a delay in reporting; this is considerable, and lowering it will help improve service quality, as prior studies have asserted. All previous studies showed and assessed the knowledge of different practices towards critical value notification policies and guidelines to our study.

Genzen and Tormey [26] observed that notification of critical values should be done by a technician on the team performing the measurement, to ensure compliance with the joint commission standards which is a non-profit organisation accredits more than 22,000 healthcare organisations between hospitals and primary clinics in the United States of America. Around 92% of responses indicated that laboratory staff are trained in reporting critical values, that is, the staff are familiar with the critical value limits and how to notify when these are breached [27]. According to Ye et al. [28], training programmes to improve delivery of critical values between relevant personnel should be undertaken. Our study found that delays in critical value reporting were significantly different between physicians and technicians, which might be due to policies and the guidelines not being followed. Past studies co-ordinated our current results and showed the attitude towards the policies and guidelines regarding critical value notification. Managing the notification time and following a flowchart to report critical values can reduce reporting errors, improve notification of critical values and further guarantee patient safety [15]. Dixon et al. [29] stated that result notification should be available in health departments within 1440 to 2880 min. Approximately 88% of respondents confirmed their setting has a policy for dealing with repeated measurement of critical values. Typically, repeating a critical value measurement does not affect the result [30]. Nonetheless, this study did not explore if there is a specific list of tests to be repeated in case a critical value arises. Furthermore, Saffar et al. [24] argue that repeating a test is unnecessary and might actually affect patient safety through delays in taking clinical action and the waste of resources [31], which is not similar to our results. A read-back policy for critical value notification is often required of the responsible person delivering it [32], and nearly 79% of respondents assured they have such a policy to follow. In addition, it is important to practice the read-back guidelines when reporting critical values to avoid communication errors; it is also a requirement of accreditation programmes [33].

Each laboratory should have their own list of critical values and recommendations taken from the medical societies, as Arbiol-Roca and Dot-Bach [34] suggest. After setting lists of critical values, their own results can be compared against those limits to meet the needs of patients and clinicians, to avoid outliers and to ensure nationwide standards [5, 35]. Furthermore, the use of unique ranges for distinct populations grouped by age and diagnosis is needed to avoid inappropriate assignment as a critical value. Valiathan et al. [36] highlighted that many studies report that age and diagnosis can affect reference ranges for lymphocytes, so checking the patient's age and diagnosis before reporting or notifying of any critical value is recommended. Our responses, compared to prior studies, showed unique ranges for age and diagnosis (63% and 41%, respectively), showing staff moderately following that concept. A separate study advised each laboratory to set their critical values list according to clinical needs [10]. Our findings revealed some differences between hospitals in the limits set for critical values, which contradicts the findings of a previous study. Such differences affect patient safety and the quality of the services provided from governmental hospitals.

Finally, because the Ministry of Health in Kuwait is responsible for almost every aspect of its hospitals, a clear notification system showing exact notification time limits is recommended for improving the quality of patient services. In addition, it is recommended that all laboratories clarify their policies concerning, for example, read-back and repeat testing after critical values have been notified. Furthermore, a unified list of upper and lower critical value limits is advisable to avoid confusion between hospitals over results.

Strengths and limitations

This study has some limitations to acknowledge. One of these is missing responses owing to respondents skipping questions. Each part of the questionnaire is considered a separate and independent section. To control that, one answered question from the questionnaire is considered a valid response and included in the analysis. The number of participating laboratories is somewhat small, a reflection of the government sector, and can be regarded as a limitation. Only tertiary hospitals were included, whereas primary care and private laboratories were excluded from this study. Furthermore, the entry and cleaning of data acquired using written questionnaires (hard copies) is laborious, although a respondent skipping questions leads to missing responses, which is considered a limitation. Also, the tool assesses staff attitudes and perceptions but not knowledge (items in Table 4 are the exceptions to this). The strength of the study is that its findings can be generalised across laboratories in Kuwait due to the use of total population sampling. This is a purposive sampling technique, a type of non-probability sampling that allows the analytical generalisation about a studied population.

Conclusions

Based on the responses of the participating hospitals, the policies and procedures for notifying on critical values at those settings are not clear. A range of responses highlighted failures to implement policy or procedures, and some staff even thought it is not essential to report if a critical value was notified. Unified critical value policies should be distributed among participating laboratories to avoid variation in reporting practices. The availability of clear policies or guidelines instructing staff on how and when to report a critical value was significantly different between hospitals. Unavailability of such guidelines leads to notifications being delayed or miscommunications owing to a lack of patient information or missed documentation. Policies and guidelines should be clear and implemented by the Ministry of Health to avoid confusion over their mandate, rather than simply being recommendations without follow-up. Notification of critical values showed some disparities between laboratories in terms of time limits and the method of delivering the notification. As our study found that differences in critical value limits between hospitals were statistically significant, that might affect a patient’s safety in the long term. Creating lists of critical values, showing the limits and the maximum notification times, and disseminating it to all laboratories, might reduce critical cases in patients and increase the quality of medical services. In the long term, the results of this study are expected to steer government policy for improving laboratory practices and patient-centred policies.

Supplementary Information

12913_2022_8329_MOESM1_ESM.docx (38.8KB, docx)

Additional file 1: Appendix 1. Laboratory Critical Values Survey (Arabic version). Appendix 2. Laboratory critical values questionnaire (English version).

Acknowledgements

We thank the Ministry of Health in Kuwait for supporting this research. We also thank the staff of the participating hospitals for facilitating the study. Special thanks go to all the health professionals who participated.

Abbreviations

ANOVA

Analysis of Variance

aPTT

Activated partial thromboplastin time

BUN

Blood urea nitrogen

IQR

Interquartile range

n

Correct responses

N

Valid responses

pCO2

Partial pressure of carbon dioxide

pO2

Partial pressure of oxygen

PT

Prothrombin time

INR

International normalisation ratio

Sec

Seconds

R

Retired (critical value was removed from laboratory policy)

V

Critical values as per hospital policy

MOH

Ministry of Health

Authors’ contributions

HAT, SZ, WAA, TAF and BAM designed the study. SZ and TAF collected and reviewed the data. SZ entered the data. HE cleaned, validated and analysed the data and developed the tables. HAK wrote the main manuscript text. TAF, GhA, HE and HAA reviewed and edited the manuscript. All authors read and approved the final manuscript. HAK is the guarantor of the manuscript.

Funding

No funding was provided for conducting this study.

Availability of data and materials

The datasets generated and/or analysed during the current study are not publicly available owing to Ministry of Health restrictions. However, datasets are available from the corresponding author upon reasonable request.

Declarations

Ethics approval and consent to participate

Ethical clearance and consent to participate to carry out the study was approved by the Standing Committee for Coordination of Health and Medical Research in Kuwait; Ethical Approval Number (690/2017). We confirm that all methods were performed in accordance with the relevant guidelines and regulations of the Standing Committee for Coordination of Health and Medical Research in Kuwait. All participants organisational names were coded to ensure their identities are anonymous and kept confidential. Verbal informed consent was obtained from all participants which was approved by the Standing Committee for Coordination of Health and Medical Research in Kuwait after an explanation of the study. All project team members signed a non-disclosure agreement.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Maharashtra P, Bhatia K, Bhatia P, Udari SN, Patil N. Study on laboratory critical value analysis in a multi-speciality hospital. MIJOBIO. 2019;12:06–9. doi: 10.26611/10021212. [DOI] [Google Scholar]
  • 2.Sharma S, Koirala B, Keyal N. A study to assess the critical result reporting at B & C Medical College and teaching hospital. J Pathol Nep. 2018;8:1350–1352. doi: 10.3126/jpn.v8i2.20871. [DOI] [Google Scholar]
  • 3.Özcan O, Çakırca G, Motor S, Yönden Z. Delays in reporting critical values from clinical laboratories to responsible healthcare staff. Turk J Biochem. 2017;42(1):45–50.
  • 4.McFarlane A, Aslan B, Raby A, Bourner G, Padmore R. Critical values in Hematology. Int Jnl Lab Hem. 2015;37:36–43. doi: 10.1111/ijlh.12226. [DOI] [PubMed] [Google Scholar]
  • 5.Mosallam R, Ibrahim SZ. Critical value reporting at egyptian laboratories. J Patient Saf. 2019;15:205–211. doi: 10.1097/PTS.0000000000000217. [DOI] [PubMed] [Google Scholar]
  • 6.Vuljanić D, Pereira M, Santos S, Nikler A, Biljak VR, Cachapuz I. Critical Results Reporting in Portuguese Hospital Laboratories: State-of-the-Art. EJIFCC. 2020;31(2):145–56. [PMC free article] [PubMed]
  • 7.Schneider F, Maurer C, Friedberg RC. International organization for standardization (ISO) 15189. Ann Lab Med. 2017;37:365–370. doi: 10.3343/alm.2017.37.5.365. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.AlSadah K, El-Masry OS, Alzahrani F, Alomar A, Ghany MA. Reporting clinical laboratory critical values: a focus on the recommendations of the American College oF Pathologists. J Ayub Med Coll Abbottabad. 2019;31(4):612–8. [PubMed]
  • 9.Zubir HK, Fuadi MR, Sulistyani E, Tito Yustiawan. Analysis of the difference of completeness of reporting and documentation of laboratory critical values pre and post-intervention in Bona Ward Dr. Soetomo HospitaL Surabaya. Indones J Clinical Pathol Med Laboratory. 2019;26(1):23–29.
  • 10.Tan EH, Yang Z, Li Y, Metz MP, Loh TP. Outcome-based critical result thresholds in the adult patient population. Am J Clin Pathol. 2019;152:177–184. doi: 10.1093/ajcp/aqz026. [DOI] [PubMed] [Google Scholar]
  • 11.Fei Y, Zhao H, Wang W, He F, Zhong K, Yuan S, et al. National survey on current situation of critical value reporting in 973 laboratories in China. Biochemia Medica. 2017;27:030707. doi: 10.11613/BM.2017.030707. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Chen J, Wu Z, Liu Y, Wang L, Li T, Dong Y, et al. Prevalence, association relation, and dynamic evolution analysis of critical values in health checkup in China: a retrospective study. Front Public Health. 2021;9:630356. doi: 10.3389/fpubh.2021.630356. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Bhutani N, Bhutani N. A Study of analysis of critical values at emergency biochemistry laboratory in a tertiary care hospital in India. Jemds. 2020;9:957–60. doi: 10.14260/jemds/2020/206. [DOI] [Google Scholar]
  • 14.Lippi G, Mattiuzzi C. Critical laboratory values communication: summary recommendations from available guidelines. Ann Transl Med. 2016;4:400–400. doi: 10.21037/atm.2016.09.36. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Li R, Wang T, Gong L, Dong J, Xiao N, Yang X, et al. Enhance the effectiveness of clinical laboratory critical values initiative notification by implementing a closed‐loop system: a five‐year retrospective observational study. J Clin Lab Anal. 2020;34. [DOI] [PMC free article] [PubMed]
  • 16.Pai S, Frater JL. Quality management and accreditation in laboratory hematology: Perspectives from India. Int J Lab Hematol. 2019;41:177–183. doi: 10.1111/ijlh.13017. [DOI] [PubMed] [Google Scholar]
  • 17.Yang Z, Tan EH, Li Y, Lim B, Metz MP, Loh TP. Relative criticalness of common laboratory tests for critical value reporting. J Clin Pathol. 2019;72:325–328. doi: 10.1136/jclinpath-2018-205549. [DOI] [PubMed] [Google Scholar]
  • 18.Lippi G, Adcock D, Simundic A-M, Tripodi A, Favaloro EJ. Critical laboratory values in hemostasis: toward consensus. Ann Med. 2017;49:455–461. doi: 10.1080/07853890.2016.1278303. [DOI] [PubMed] [Google Scholar]
  • 19.The Institute for Quality and Efficiency in Health Care . What are clinical practice guidelines? Institute for Quality and Efficiency in Health Care (IQWiG) 2016. [Google Scholar]
  • 20.Başaran N, Evliyaoğlu O, Yıldırmak S, Vurgun E. Effectiveness of critical laboratory value reporting: an evaluation by clinicians. Türk Klinik Biyokimya Derg. 2019;17:10–16. [Google Scholar]
  • 21.Piva E, Sciacovelli L, Pelloso M, Plebani M. Performance specifications of critical results management. Clin Biochem. 2017;50:617–621. doi: 10.1016/j.clinbiochem.2017.05.010. [DOI] [PubMed] [Google Scholar]
  • 22.Clavijo A, Fallaw D, Coule P, Singh G. Communication of critical laboratory values: optimization of the process through secure messaging. Lab Med. 2020;51:e6–11. doi: 10.1093/labmed/lmz047. [DOI] [PubMed] [Google Scholar]
  • 23.Higgins C. Critical values in laboratory medicine. 2011. https://acutecaretesting.org/en/articles/critical-values-in-laboratory-medicine. Accessed 8 Nov 2021.
  • 24.Saffar H, Abdollahi A, Hosseini AS, Torabi Farsani M, Hajinasrollah G, Mohaghegh P. Necessity of routine repeat testing of critical values in various working shifts. Iran J Pathol. 2020;15:161–166. doi: 10.30699/ijp.2020.99403.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Bhartia S, Wahi P, Goyal R. Reducing delay in laboratory reports for outpatients from 16% to <3% at a non-profit hospital in New Delhi. India BMJ Open Qual. 2019;8:e000547. doi: 10.1136/bmjoq-2018-000547. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Genzen JR, Tormey CA. Pathology consultation on reporting of critical values. Am J Clin Pathol. 2011;135:505–513. doi: 10.1309/AJCP9IZT7BMBCJRS. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Plebani M. Towards a new paradigm in laboratory medicine: the five rights. Clinical Chemistry and Laboratory Medicine (CCLM). 2016;54:2–9. [DOI] [PubMed]
  • 28.Ye YY, Zhao HJ, Fei Y, Wang W, He FL, Zhong K, et al. Critical values in hematology of 862 institutions in China. Int J Lab Hem. 2017;39:513–520. doi: 10.1111/ijlh.12681. [DOI] [PubMed] [Google Scholar]
  • 29.Dixon BE, Zhang Z, Lai PTS, Kirbiyik U, Williams J, Hills R, et al. Completeness and timeliness of notifiable disease reporting: a comparison of laboratory and provider reports submitted to a large county health department. BMC Med Inform Decis Mak. 2017;17:87. doi: 10.1186/s12911-017-0491-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Lehman CM, Howanitz PJ, Souers R, Karcher DS. Utility of repeat testing of critical values: a Q-Probes Analysis of 86 clinical laboratories. Arch Pathol Lab Med. 2014;138:788–793. doi: 10.5858/arpa.2013-0140-CP. [DOI] [PubMed] [Google Scholar]
  • 31.Sun S-CP, Garcia J, Hayden JA. Repeating critical hematology and coagulation values wastes resources, lengthens turnaround time, and delays clinical action. Am J Clin Pathol. 2018;149:247–52. doi: 10.1093/ajcp/aqx156. [DOI] [PubMed] [Google Scholar]
  • 32.Lam Q, Ajzner E, Campbell CA, Young A. Critical Risk Results – An update on international initiatives. EJIFCC. 2016;27:66–76. [PMC free article] [PubMed] [Google Scholar]
  • 33.Rocha BCB. et al. The critical value concept in clinical laboratory. Jornal Brasileiro de Patologia e Medicina Laboratorial [online]. 2016;52(1):17–20. 10.5935/1676-2444.20160008.
  • 34.Arbiol-Roca A, Dot-Bach D. Survey on Stat Tests in Catalan Clinical Laboratories. EJIFCC. 2020;31(2):134–44. [PMC free article] [PubMed]
  • 35.Long-Mira E, Washetine K, Hofman P. Sense and nonsense in the process of accreditation of a pathology laboratory. Virchows Arch. 2015;468:43–49. doi: 10.1007/s00428-015-1837-1. [DOI] [PubMed] [Google Scholar]
  • 36.Valiathan R, Ashman M, Asthana D. Effects of ageing on the immune system: infants to elderly. Scand J Immunol. 2016;83:255–266. doi: 10.1111/sji.12413. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

12913_2022_8329_MOESM1_ESM.docx (38.8KB, docx)

Additional file 1: Appendix 1. Laboratory Critical Values Survey (Arabic version). Appendix 2. Laboratory critical values questionnaire (English version).

Data Availability Statement

The datasets generated and/or analysed during the current study are not publicly available owing to Ministry of Health restrictions. However, datasets are available from the corresponding author upon reasonable request.


Articles from BMC Health Services Research are provided here courtesy of BMC

RESOURCES